Report printed Aug 05, 2018 at 10:17:18

650.000000 <---- Line Temperature (deg. F)


450.000000 <---- Pressure (abs) (lb./sq.in.) [Must be > 30.0]
2.141000 <---- ID of Relief Valve Orifice (in.)
5.761000 <---- ID of Relief Valve Piping (in.)
7.961000 <---- ID of Vent Stack Piping (in.)
18.000000 <---- Length of Vent Stack (ft.)
1.300000 <---- Ratio of Gas Specific Heats (k) [Air = 1.4]
85.800003 <---- Gas Constant (R) (ft.lb./lbm/deg.R) [Air = 53.0 ]
N <---- Does the Vent Pipe have an Umbrella fitting (Y/N)
N <---- Should CAESAR II size the Vent Stack (Y/N)

Computed Mass Flowrate (Vent gas) ..... (lbm /hour) 71557.883


Thrust at Valve Pipe/Vent Pipe Interface ... (lb. ) 2838.028
Thrust at Vent Pipe Exit ................... (lb. ) 1285.051
Transient Pressure Rise, Valve Opening (lb./sq.in.) 60.121
Transient Pressure Rise, Valve Closing (lb./sq.in.) 44.093
Thermodynamic Entropy Limit (Should be > 1) ...... 1.083
Subsonic Vent Exit Limit (Should be > 1) ...... 1.330
(lb./sq.in.--abs) (ft./s) (deg F)
Valve Orifice Gas Conditions ... (P,Vel,T) 245.6 1861.9 505.2
Vent Pipe Exit Gas Conditions .. (P,Vel,T) 19.7 1675.3 505.2
Subsonic Velocity Gas Conditions (P,Vel,T) 26.1 1335.0 558.1