Вы находитесь на странице: 1из 55

MUNICIPAL CORPORATION OF

GREATER MUMBAI
TRAFFIC DEPARTMENT

VOLUME-I

UNIFIED SCHEDULE OF RATES FOR

TRAFFIC AND SIGNALLING WORKS

2014
FOREWORDING NOTE
Ever since establishment of Bombay Municipal Corporation (now Municipal
Corporation Of Greater Mumbai) in 1888 by the erstwhile British rulers in India , in
the last 125 years of the history of its existence MCGM has catered to every aspect
of the citizen of Mumbai that can be conceived of. Look to heritage buildings like
Victoria Terminus (Chhatrapati Shivaji Terminus), Office of Municipal Corporation,
Dadabai Naoroji Road, Dr. Babasaheb Ambedkar Road, Marine Drive (Netaji
Subhash Road), Prince of Wales Museum, Gateway of India, Malabar Hill Reservoir,
Nair Hospital, Lokmanya Tilak Hospital, KEM Hospital etc which are the service
centers for the citizens. Municipal Services have also been provided in the suburban
and extended suburban areas merged in 1950 & 1957 respectively. The obligatory
duties are performed well but still there is need to improve in quantity and quality of
services to be provided to the citizens.

Ethical governance and righteous work culture will certainly bring positive
changes in design and implementation of projects. One may take an example of the
first Municipal Head Quarter Building, that was completed in year 1893, in four years,
designed by F W Stevens and the execution part was dealt by Project Engineer Shri
RaoSaheb Sitaram Khanderrao Vaidya, who executed the project of 77.70m high
structure and saved Rs.68,000/- as against estimated cost of Rs. 11.80 Lakhs.

The need is to work with precision and accuracy. There shall be harmony
between planning and execution so as to evolve best economics with focused goals.

MCGM is one of the largest local self government in the Asian Continent. In
observance of historic traditions of strong civic activism, with the change in time and
living conditions to match with the urbanization, MCGM has focused in providing
variety of engineering services viz, storm water drain, sewerage, water supply,
roads, bridges, solid waste management, environmental services. Beside this, the
Corporation is also providing dedicated services in the Health sector by establishing
Major and Peripheral hospitals.

To update and modernize the mechanism being used for working on related projects
from the stage of conceptualization to execution, the need was realized to revise
prevailing “Schedule Of Rates” along with specifications which were in operation with
various departments and being prepared individually as per their need and revised at
different span of time, resulting into various anomalies. To overcome all these, it was
essential to revise the schedule of rates, not only with simple mechanized revision
but incorporating major changes to keep up with the pace of urbanization, civilization,
construction techniques / mechanization and voluminous developments by
restructuring items in the schedule to cover all requirements. This exercise would
provide comfort with designs and field necessities and will assist in effective checks
on creation of extra items during execution.

A conscious decision has been taken to prepare Unified Schedule of Rates to keep
pace with the changing time; a first step forward in this direction. Since long time,
there have been demands made by the stake holders like Municipal Engineers and
Contractors to remove non-uniformity, anomalies and discrepancies in various
schedules of rates for work contracts of various departments of MCGM. Every
department had its own expertise and way of functioning which got reflected in its
independent schedule of rates, which however, had no linkage with the fair market
rates and schedules of other departments, resulting into extra items and fair rates. In
place of earlier 9 Schedule Of Rates, the Unified Schedule of Rates is an effort and
seeks to rectify the defects, discrepancies and non uniformities which will provide
ease and accuracy of estimation to the Engineers.

In view of the enormous and voluminous nature of work, keeping time frame
in perspective and above all, to ensure professionalism, the work of preparation of
Unified Schedule of Rates (USR) was awarded to the eminent consultants M/s.Tata
Consulting Engineers Ltd. M/s.Tata Consulting Engineers Ltd were directed to
conduct a integrated factual market research for major materials from
stockists/manufacturers/dealers and to study schedules of rates of Govt bodies like
C.P.W.D., P.W.D. etc The new Rate Analysis are based on Factual Market research
done by M/s.Tata Consulting Engineers Ltd.

The anomalies in rate are minimized after extensive market research and collection
of quotations from reputed large scale stockists/dealers, and also after comparison
with rates of CPWD, PWD etc.

The Unified Scheduled of Rates is linked with its comprehensive specifications of


basic important activities so as to have clarity in execution. These specifications
follow a chronology of general scope of the item, material required, processing of
material, construction operation, finishing and mode of measurement. Rigid Standard
Operating Procedures (SOPs) and complete control on processes will certainly
satisfy quality parameter. The need for checking the quality of construction is quite
apparent and shall be ensured throughout the construction process. To achieve this,
the Unified Scheduled of Rates incorporates quality assurance procedures.

All the rates are also linked to their detailed specifications and wherever required,
with drawings. Though there are about 12500 items, every item is now given a
Unique Code No. which will eliminate the repetition.

It has been our endeavor to include all the necessary modern materials and
technologies in Unified Schedule of Rates, for example, the concept of green
building, which will go a long way to have control on creation of extra items and fair
rates. A salient feature of this Unified Schedule of Rates is 'Starring of items'
specified categorically which can be used only at certain works or locations.

Another salient feature is 'Dynamic Rate System' which will be based on


study of data base of quantities and bidding prices of awarded contracts on the basis
of which necessary corrections can be applied to the Unified Schedule of Rates at
specified intervals. The MCGM will be now be in a position to revise the Unified
Scheduled of Rates every year, after incumbency period of M/s.Tata Consulting
Engineers Ltd of one year, to work with and correct the system as and when
necessary.

I am sure that this 'Unified Scheduled of Rates' will be a milestone in civic


governance by MCGM. This publication shall be of great help and guidance to the
officers engaged in the project work of MCGM.

A.M.C. (Project) Municipal Commissioner


GENERAL NOTES

A. COMMON GENERAL NOTES

1. The schedule of rates will be operative from 19-05-2014


2. The unified schedule of rates includes following department:

i. Buildings

ii. Water Supply Projects

iii. Hydraulic Engineering

iv. Sewerage Projects

v. Storm Water Drainage

vi. Roads

vii. Bridges

viii. Traffic and Signals

ix. Mechanical and Electrical

x. Garden Works

3. Volume-I contains USR, basic rate list and approved makes and Volume-II
contains specification along with drawings wherever necessary and mandatory
tests.

4. The specification of the items shall be as per latest Indian Standard Codes unless
otherwise specified.

5. The rates of the items in this schedule of rates are worked out assuming average
lead for Greater Mumbai area for all sorts of materials.

6. The rates are inclusive of transportation, duties, taxes and charges of all
Government, Municipal or any other statutory body, applicable from time to time
but exclusive of Works Contract Tax and Labour Cess levied by Government of
Maharashtra.

7. The rates also includes Overheads @ 5% and Contractor’s Profit @10% which is
inclusive of labour supervision charges, tools and plants.

8. Rates of common material and labour is attached in the Annexure-A in Volume-I.

9. The building Schedule of Rates 2014 includes the existing items of FMA, FMB
2009, SIC and Fair items, with deletion of obsolete items, merger of similar items
and value addition of new items in line with modern technology and trends in
accordance with latest rules, regulation, byelaws etc.

10. As per the Government policy the use fly ash is done for framing the items of
work in accordance with the latest provisions of IS Codes. Also green building
items have been introduced in new schedule to minimize the consumption of
energy during construction and occupancy of building and also maintaining
ecological balance.

11. From safety, health and environment point of view two legged steel tubular
scaffolding shall be used, without making any holes in the outer face of the
building or any structure. And no extra payment shall be made for works like
scaffolding, centering for any height unless otherwise specified.

12. All materials shall be as per approved list of MCGM or equivalent material having
quality standards as per relevant IS codes and shall be of first quality unless
otherwise specified.

13. Following basic rates are considered in the USR:

i. Cement : Rs. 6,000/ MT

ii. Mild Steel : Rs. 47,400/ MT

iii. HYSD Steel (Fe415) : Rs. 48,400/ MT

iv. T.M.T. (Fe500) : Rs. 49,400/ MT

v. Structural Steel : Rs. 53,400/ MT

14. Rates given in SOR are for estimation purpose.

15. Rates of items and specification for excavation, concrete, plaster and brickwork
shall be referred from common schedule unless and otherwise not mentioned in
concerned department’s schedule.

For Earthwork:

16. Lead will be admissible only within MCGM limits. The distance between
centerlines shall be taken as the lead which shall be measured by the shortest
route on the plan and not the actual route taken by the Contractor. Here
Centerlines represents the center point (for area/mass excavation) and the center
chainage for linear excavation.
17. The Engineer In Charge shall exclusively include these directions in the
Tender/Bid document and the Tenders/Bidders shall be insisted to make the
declaration of the dumping plot at the time of submission of Bid.

18. The Engineer In Charge shall take the quantity in account for the disposal only
upto Municipal Limits for the Shortest Route and payment will be made as per the
actual distance within municipal limit. The payment will be restricted to the
shortest distance upto the Municipal limit for the plot identified outside the
Municipal limit.

For Lift:

19. For the depth beyond 1.5 meter, the excavated quantity shall be worked out with
the base rate plus the rate of respective slab of the lift. This is elaborated as
below:

If total depth of excavation is 6 meter, wherein for first 4.5 meter soft soil is there
and beyond it hard rock is available, then estimate shall be worked out as follows:

Assumed dimension 1 meter x 1 meter x 6 meter

Upto 4.5 meter depth, amount shall be calculated as:


1.5
(1x1x4.5) Cu.M x Rs. 220 (Item no. CS-EW-1) + 5
SOFT 1.5
(1x1x1.5) Cu.M x Rs. 48 (Item no. CS-EW-2-a) +
5
1.5
(1x1x1.5) Cu.M x Rs. 71 (Item no. CS-EW-2-b)
5
For next hard strata excavation (4.5 – 6.0 meter), HARD 1.5
amount shall be calculated as: 5

(1x1x1.5) Cu.M x Rs. 873 (Item no. CS-EW-4) +

(1x1x1.5) Cu.M x Rs. 220 (Item no CS-EW-7-c)

20. Coding of items:


 The Coding procedure for Basic master material is as follows:
Code will start with the common prefix of “MA” which stands for materials
Followed by Abbreviation code for each schedule of rate for eg H.E. for
Building works, SP for Sewerage, WSP for water supply and so on and so
forth.
The first item category in the list will be numbered as “1”
The last part of the code will be a number starting with “a” to indicate the item
number in the master list.
The alpha numerics will be separated by (dash).
The code will look like: MA-GN-01
 The Coding procedure for SOR is as follows:

Code will start from abbreviation for Department name “HE” or “WSP” or “SP”
The USR will be subdivided into chapters according to the item classification;
these chapters will be numbered as 1, 2, 3 …..
The items under the chapter will be numbered from 1
The sub items will be numbered as a, b, c ….
The code will look like CS-CW-1-a-1

 Abbreviations to be used for Department

Sr. No. Department Abbreviation

1 Building works/Common CS
Schedule
2 Roads RW

3 Traffic and Signaling RT


4 Bridges BW
5 Water Supply Projects WSP
6 Hydraulic Engg. HE
7 Sewerage Projects SE
8 Storm Water Drains SWD
9 Mechanical and electrical ME
10 Garden Works GW
B. SALIENT FEATURES OF SOR FOR BUILDING WORKS
1) All the rates are for all heights and levels unless noted otherwise.
2) Chloropyrifos EC 20 has been considered for anti termite treatment.
3) Artificial sand (crushed sand) has been considered for flooring bedding and for
concrete work.
4) All the items are excluding fixtures otherwise not specified in respective item. In such
case, items of Hardware section shall be used for fixtures.
5) For plastering and mortar work, river sand has been considered.
6) For plastering work all the rates are for all heights and levels and architectural
decorative surface.
7) All external plaster items are including waterproofing compound except plastering
item for structures like compound wall, masonry pedestals, pillars, etc.
8) Items for ashlar masonry, dewatering, self compacting concrete, vacuum dewatered
concrete flooring and TMT steel bars have been introduced.
9) Rates of all the items in roofing work are inclusive of staging or scaffolding for any
height.
10) Non-asbestos cement sheet provided in place of asbestos cement sheet roofing.
11) Concreting of pile shall be done with RMC only.
12) Rates of piling are inclusive of Chiseling of intermediate local boulders. No separate
payment shall be made for the same
13) While estimating the quantity for Grouting of bentonite slurry in bored precast piles
shall be measured as per bore dia. and pile dia. Exact quantity can be measured
while execution and shall be paid accordingly
14) Rates considered in concrete items are including pumping of concrete upto placing
point.
15) New items like Self compacting concrete, vacuum dewatered concrete flooring and
TMT steel bars have been introduced.
16) The dismantling and demolishing chapter covers only removing old items and repair
work covers both removing old items and re-fixing the new.
17) For heritage works the rate includes the statutory charges for heritage committee and
conservation architect and no extra payment will be made.
18) APP (Atactic poly-propylene) modified polymeric membrane water proofing will be
used only for trial basis on approval of City Engineer and/or Chief Engineer (P&D).
19) In plumbing waterless urinals, fly ash bricks, fly ash concrete for green building
concept have been introduced.

Star Rating:
In view of ambiguity related to choice of quality or grade of materials and subsequent
items of works to be used at Ward level projects, Centralized projects or Special projects
of and for smooth functioning during planning stage of a project, the new concept of Star
Rating has been introduced for building works depending on the life expectancy of
building, degree of occupancy of building and comfort to the end user. The buildings or
structures rated are as follows:

i. Two Star **- Ward offices and Central dept. Offices, schools, Small Hospitals,
Primary Health Center, Fire Station, Crematorium, Slaughter Houses,
Markets, Swimming Pools, Zoos, Chowkies, Libraries, Staff quarters and
residential colonies, Public Toilets and Water tanks.

ii. Three Star ***- Super specialty Hospitals, Drama Theatres, MCGM Mayor’s
and Officer’s bungalow, Heritage Structures, Head Office and Engineer’s
Hub.
The items or work not marked as two star or three star are assumed to be
applicable for all the star buildings or structures mentioned above.
MUNICIPAL CORPORATION OF GREATER VOLUME-I
MUMBAI
Traffic Department Unified Schedule of Rates

Sr.
Content ITEM CODE PAGE NO.
No.
1 Controller RT-1 1-2

2 PCBs RT-2 2-3

3 Piping RT-3 3-4

4 Signal/CCTV/Video detection poles RT-4 4-5

5 Junction box and power supply RT-5 6-6

6 Signal heads RT-6 6-7

7 Cables RT-7 7-8

8 Flashers RT-8 9-9

9 Vehicle detector camera RT-9 9-10

10 Control room related RT-10 10-14

11 CCTV camera RT-11 14-15

12 Variable messaging signboards RT-12 15-16

Preventive & Corrective Maintenance,


13 RT-13 16-17
SITC of Junctions & Miscellaneous Items

14 Civil works RT-14 17-21

15 Dividers RT-15 21-26

16 Street Furniture and Signages RT-16 26-44


Traffic Department Schedule
2014
DESCRIPTION OF ITEMS: ATC + NON ATC SOR - Mumbai Traffic Control System
Sr No. Code No. Item Description Unit Rate in Rs.
1 RT-1 CONTROLLER
Supply of Type 4 controller (13-16 phases)M/s
TELVENT make with controller cabinet.
Provide red lamp monitoring, ATC (outstation
1 RT-ATC 1.1 modem) interface with optical fibre cables, Nos. 620724
Cable-less Linking facility etc.Controller shall
support ITACA Traffic mamagement system in
Mumbai.
Supply of Type 4 controller (13-16 phases) of
equivalent to TELVENT or PEEK make with
controller cabinet. Provide red lamp monitoring,
2 RT-ATC 1.2 ATC (outstation modem) interface with optical Nos. 681626
fibre cables, Cable-less Linking facility
etc.Controller shall support ITACA Traffic
mamagement system in Mumbai.
Supply of Type 5 controller (17-20 phases) M/s
TELVENT make with controller cabinet.
Provide red lamp monitoring, ATC (outstation
3 RT-ATC 1.3 modem) interface with optical fibre cables, Nos. 675481
Cable-less Linking facility etc.Controller shall
support ITACA Traffic mamagement system in
Mumbai.
Supply of Type 6 controller (over 21
phases)M/s TELVENT make with controller
cabinet. Provide red lamp monitoring, ATC
4 RT-ATC 1.4 (outstation modem) interface with optical fibre Nos. 730239
cables, Cable-less Linking facility etc.Controller
shall support ITACA Traffic mamagement
system in Mumbai.
Supply of Microprocessor based Automatic
traffic signal controller with housed in a water
proof, dust proof & dust tight cabinet with
internal locking arrangement , Police panel
5 RT-NATC 1.5 Nos. 96259
etc., incorporating the following – minimum 16
timing plans & 12 phases, 7 day clock, with 16
groups with minimum 48 lines with conflict
management facility.
Supply of S.S 304 controller cabinet for ATC
controllerswith canopy construction having
6 RT-ATC 1.6 Nos. 43440
sheet of thickness 1.6mm with IP 65 protection
as per attached drawing.
Supply of controller cabinet for Non ATC
controllers of M.S. Sheet material of 2 mm
7 RT-NATC 1.7 Nos. 26352
thickness with I.P.-65 protection having size of
600X300X1200 mm (WXDXH)
Installation,testing and commissioning of all
8 RT-ATC 1.8 Nos. 15158
types of ATC controller
9 RT-ATC 1.9 Removal of ATC Controller Cabinet Nos. 4539
Sealing of controller with bitumen / foam for
10 RT-ATC 1.10 Nos. 5674
achieving IP 55 protection.
Installation & commissioning of Non ATC
Traffic Signal Controller Including all Fittings on
11 RT-NATC 1.11 Nos. 3631
PCC foundation.( Excluding PCC
foundation).

1
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Installation and commissioning of Non-ATC
12 RT-NATC 1.12 Nos. 1515
controller on pole as specified
Removal of NON ATC signal controller from
13 RT-NATC 1.13 Nos. 1769
foundation or pole
Supply of digital count down timer for non-ATC
14 RT-NATC 1.14 Nos. 21243
Signal Junctions ( EN 12966 ) Graphic Type

Installation and commissioning of contdown


15 RT-NATC 1.15 Nos. 607
timer for non-ATC Signal Junctions
Supply of count down timer (2 1/2 digit 8" digit
height dual colour) for non-ATC Signal
16 RT-NATC 1.16 Nos. 14007
Junctions as per latest IS, BS or equivalent
standards
Removal of count down timer from pole as
17 RT-NATC 1.17 Nos. 153
specified

Earthing Pit with 50 mm dia. G.I. pipe, 3000mm


long GI pipe (Class B or better) earth pit as per
IS 3043. The earth pit shall be provided with
watering pipe (Class B) with wire messed
funnel, 25x6 GI strip / 8 SWG GI wire up to
chamber (wire or strip size as per fault level),
18 RT-ATC 1.18 Nos 6525
disconnecting links with 450 x 450 mm (clear)
RCC chamber & heavy duty 3mm thick CI
chequered plate cover with hinge & stainless
steel bolts. Bentonite/ Charcol & Salt shall be
provided for earth pits. Excavation, backfilling,
removal of excess soil is included in the scope

2 RT-2 PCBs
Supply of M/s TELVENT make Group Card
19 RT-ATC 2.1 Nos. 33761
TGRY-306/5 V2.3
Supply of M/s TELVENT make TCE Card TCE-
20 RT-ATC 2.2 Nos. 41227
486/3
Supply of M/s TELVENT make Micro-1 Card
21 RT-ATC 2.3 Nos. 37655
TMRY-478/3 V6
Supply of M/s TELVENT make Micro-2 Card
22 RT-ATC 2.4 Nos. 35940
TMRY-478/3 V7
Supply of M/s TELVENT make Input/Input
23 RT-ATC 2.5 Nos. 41328
Card EERY-274/2 V2
Supply of M/s TELVENT make Input/Output
24 RT-ATC 2.6 Nos. 25431
Card ESRY-384/4V2
Supply of M/s TELVENT make SMPS Card
25 RT-ATC 2.7 Nos. 35193
FAY-267/12 V1.3
Supply of M/s TELVENT make REY Card
26 RT-ATC 2.8 Nos. 63848
REY42-544
Supply of M/s TELVENT make RESY Card
27 RT-ATC 2.9 Nos. 38694
RESY-42/542 V2
Supply of M/s TELVENT make Back Plane
28 RT-ATC 2.10 Nos. 11261
Mother Board Card-BPRY-311/3 V2
Supply of M/s TELVENT make Back Plane
29 RT-ATC 2.11 Nos. 8113
Mother Board Card-BSRY-312/2 V2
Supply of M/s TELVENT make Main Rack 6 U,
30 RT-ATC 2.12 depth 80 mm with division for detectors and Nos. 38121
guides for RMY32, without bus

2
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply of audible beeper unit with all require
31 RT-NATC 2.13 Nos 2369
accessories.
Installation and commissioning of audible
32 RT-NATC 2.14 Nos 300
beeper unit.
33 RT-NATC 2.15 Removal of audible beeper unit. Nos 131
Supply, Installation and commissioning of Push
34 RT-ATC 2.16 button assembly including display / instruction Nos 9586
board as per drawing
35 RT-NATC 2.17 Removal of Push button assembly Nos 567
3 RT-3 PIPING
Supply of single120mm (OD)/100 mm (ID)
double walled corrugated High Density Poly
36 RT-NATC 3.1 Ethylene (HDPE) Pipes conforming to the IS Mtr 174
14930 (Part-II) including supply of necessary
sockets, couplings etc.
Laying of single 120mm (OD)/ 100 mm (ID)
double walled corrugated High Density Poly
Ethylene (HDPE) Pipes including pull wire
37 RT-NATC 3.2 Mtr 11
along with necessary sockets, couplings etc.
and as per drawing no. RT-NATC-3.2A & RT-
NATC-3.2B
Supply of single 63 mm (OD)/ 51 mm (ID)
double walled corrugated High Density Poly
38 RT-NATC 3.3 Ethylene (HDPE) Pipes conforming to the IS Mtr 71
14930 (Part-II) including supply of necessary
sockets, couplings etc.
Laying 63 mm (OD)/ 51 mm (ID) double walled
corrugated High Density Poly Ethylene (HDPE)
39 RT-NATC 3.4 Pipes including pull wire along with necessary Mtr 6
sockets, couplings etc. as per drawing no. RT-
NATC-3.2A & RT-NATC-3.2B
Supply of single 50 mm (OD)/ 37 mm (ID)
double walled corrugated High Density Poly
40 RT-NATC 3.5 Ethylene (HDPE) Pipes conforming to the IS Mtr 55
14930 (Part-II) including supply of necessary
sockets, couplings etc.
Laying 50 mm (OD)/ 37mm (ID) double walled
corrugated High Density Poly Ethylene (HDPE)
41 RT-NATC 3.6 Pipes including pull wire along with necessary Mtr 6
sockets, couplings etc. as per drawing no. RT-
NATC-3.2A & RT-NATC-3.2B
Supply of 100 mm Dia. Class 'A' G.I. pipe
42 RT-NATC 3.7 including Supply of necessary accessories suct Mtr 833
as G.I. couplers etc.
Laying of 100 mm Dia. Class 'A' G.I. pipe with
43 RT-NATC 3.8 provision of Pull Boxes etc. as per drawing no. Mtr 113
RT-NATC-3.2A & RT-NATC-3.2B
Supply of 65 mm Dia. Class 'A' G.I. pipe
44 RT-NATC 3.9 including Supply of necessary accessories suct Mtr 506
as G.I. couplers etc.
Laying of 65 mm Dia. Class 'A' G.I. pipe, with
45 RT-NATC 3.10 provision of Pull Boxes etc. as per drawing no. Mtr 68
RT-NATC-3.2A & RT-NATC-3.2B

3
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply of 50 mm Dia. Class 'A' G.I. pipe
46 RT-NATC 3.11 including Supply of necessary accessories suct Mtr 375
as G.I. couplers etc.
Laying of 50 mm Dia. Class 'A' G.I. pipe, with
47 RT-NATC 3.12 provision of Pull Boxes etc.as per drawing no. Mtr 57
RT-NATC-3.2A & RT-NATC-3.2B
Removal of existing all types of Class 'A' G.I.
48 RT-NATC 3.13 Mtr 51
pipe G.I. Pipe excluding excavation.
Removal of existing single 120mm (OD)/ 100
mm (ID) double walled corrugated High
49 RT-NATC 3.14 Mtr 27
Density Poly Ethylene (HDPE) Pipe excluding
excavation.
Removal of existing single 50 mm (OD)/ 37
mm (ID) double walled corrugated High
50 RT-NATC 3.15 Mtr 27
Density Poly Ethylene (HDPE) Pipe excluding
excavation.
SIGNAL / CCTV / VIDEO DETECTION
4 RT-4
POLES
Supply of Galvanised Iron Class B Traffic
51 RT- ATC 4.1 Signal straight pole of 6 mtr height as per Nos 11449
Specification
Supply of Galvanised Iron Class B Traffic
52 RT- ATC 4.2 Nos 32372
Signal cantilever pole of as per Specification
Supply of Galvanised Iron Class B straight pole
53 RT- ATC 4.3 Nos 31227
of 8.75 mtr height as per Specification
Supply of Galvanised Iron Class B straight pole
54 RT- ATC 4.4 Nos 31661
of 11 mtr height as per Specification
Supply of Galvanised Iron Class B straight pole
55 RT- ATC 4.5 Nos 16202
of 7 mtr height as per Specification
Supply of Galvanised Iron Class B straight pole
56 RT- ATC 4.6 of 8.75 mtr height WITH CCTV camera Nos 49979
accessories as per Specification
Supply of Traffic Signal swing type cantilever
57 RT- ATC 4.7 Nos 37386
pole of as per Specification
Supply of swing armextended arm of 4mtr
58 RT- ATC 4.8 Nos 12554
length as per Specification
Supply of fix base of 5mtr height as per
59 RT- ATC 4.9 Nos 20015
Specification
Supply of extended arm of 4mtr length as per
60 RT- ATC 4.10 Nos 12554
Specification
Supply of Traffic signal Straight pole of 6 mtr,
inner dia 100 mm from resistant to peeling with
base plate size of ( LXWXT) 200mm
61 RT- NATC 4.11 X200mmX6mm painted with redoxide and Nos 11449
double coat with synthetic enamel paint of
yellow colour assembly G.I., class B, as per
technical specification

4
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply of Traffic signal Cantilever pole Class B
having inner diameter of 100 mm or more with
a height of 6m including extension arm
assembly having outer diameter of 75mm with
62 RT- NATC 4.12 arm span of 4 mtr Nos 21730
length and base plate of size 300mm X 300mm
with thickness of 6
mm welded at the bottom of the pole base as
per technical specification & drawings.
Supply of Straight pole 100mm dia assembly
63 RT- NATC 4.13 G.I., class B, 3 mtr length as per technical Nos 4737
specification & drawings.
Supply of Traffic signal Straight pole assembly
G.I., class B 6 mtr. Height and 100 mm dia,
64 RT- NATC 4.14 Nos 7896
with base plate 200mmX200mm at bottom for
solar flasher unit as per technical specification.

Supply of Traffic signal Straight pole assembly


6 mtr length for solar flasher unit with solar
65 RT- NATC 4.15 collector fixing facility & battery cabinet fixing Nos 27027
facility for RF signal junctions as per technical
specification & drawings. (RF)
Supply of Traffic signal Cantilever pole
assembly as per technical specification &
66 RT- NATC 4.16 Nos 42005
drawings with facility to fix solar collectors &
battery as per specifications. (RF)
Supply of Traffic signal pole cantilever pole
67 RT- NATC 4.17 Nos 12822
extension arm (RF)
Supply of Polycarbonate pole cap suitable for
68 RT- ATC 4.18 NB 100 mm without terminal chessis and Nos 332
terminals as per drawing
Supply, Installation and commissioning of
69 RT- ATC 4.19 Electrical interface housing cable termination of Nos 1010
cantilever pole as per drawing
Supply of Cast Iron Brackets for mounting
70 RT- ATC 4.20 Nos 521
signal light aspect on pole as per drawing
Supply of standard neoprene rubber gasket
suitable for cantilever pole door and at cable
71 RT- ATC 4.21 Nos 134
entry portion of straight pole and cantilever
pole
Supply, Installation and commissioning of Pole
72 RT- ATC 4.22 Cap Termination Assembly for straight pole as Nos 1362
per drawing
Fixing of Traffic Signal fix type and swing type
73 RT- ATC 4.23 Nos 2270
Cantilever pole extension arm
74 RT- ATC 4.24 Removal of Traffic signal straight pole Nos 3972
Removal of Traffic signal cantilever pole with
75 RT- ATC 4.25 Nos 7376
extension arm or camera pole assembly
Removal of Traffic signal pole cantilever pole
76 RT- ATC 4.26 Nos 2270
extension arm
ELI Test for Poles and incoming electric Supply
77 RT- ATC 4.27 of Signal Junction with FLUKE Meter and Per Junction 2270
submission of ELI Test Report

5
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
5 RT-5 Junction Box & Power Supply
Supply of 2 mm thick 310 mm x 215 mm x 100
mm MS junction box including providing cover
with provision to adjust overall height, knock
78 RT- NATC 5.1 Nos 908
outs on four sides to accept cables of specified
sizes and including elmex connector, gland,
cable terminations etc

installation of 2 mm thick 310 mm x 215 mm x


79 RT- NATC 5.2 Nos 148
100 mm MS junction box as described above
80 RT- NATC 5.3 Removal / dismantling of existing Jn. Box Nos 113
Supply of power supply box 600mm X 400mm
X 300mm (HXWXD), with canopy made in
welded construction of S.S. 304 material
81 RT- NATC 5.4 Nos 10770
having sheet of thickness 1.6mm with IP 65
protection as per technical specification and as
per requirement of power supply authority
Installation & commissioning of power supply
82 RT- NATC 5.5 Nos 1838
box.
Removal / dismantling of existing power supply
83 RT- NATC 5.6 Nos 221
box (M.S./S.S.)
Supply & installation of new anchor fastener of
84 RT- NATC 5.7 S.S.material of 8 mm dia and length of 100mm Nos 202
with removal of existing fixed studs
Supply, Installation, Testing and
commissioning of Police Panel Box(inclusive of
85 RT- NATC 5.8 Nos 553
Rotary Switch & Push Button) of Non-ATC
Controller
Supply & Installation of junction box cover for
86 RT- NATC 5.9 Nos 51
NON ATC
6 RT-6 Signal Heads
Supply of 300 mm dia – single source – LED
87 RT- ATC 6.1 Nos 6198
retrofit - Red (blow) as per Specification

Supply of 300 mm dia – single source – LED


88 RT- ATC 6.2 Nos 6198
retrofit - Amber (blow) as per Specification
Supply of 300 mm dia – single source – LED
89 RT- ATC 6.3 retrofit - Green (arrow/U- Turn) EN-12368 as Nos 7378
per Specification
Supply of 300 mm dia – single source – LED
90 RT- ATC 6.4 retrofit - Red (ped. standing) EN-12368 as per Nos 6198
Specification
Supply of 300 mm dia – single source – LED
91 RT- ATC 6.5 retrofit - Green (ped.walking) EN-12368 as per Nos 7378
Specification
Supply of 300 mm dia – single source – LED
92 RT- ATC 6.6 retrofit - Amber (arrow) EN-12368 as per Nos 6198
Specification
Supply of 300 mm dia - No Right Turn/No Left
turn/No Straight/No ‘U’ Turn aspects by using
93 RT- ATC 6.7 Nos 3795
UV stabilized ink on face plate EN-12368 as
per Specification

6
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply of Polycarbonate LED Signal head
housing 300 mm dia. as per ATC technical
94 RT- ATC 6.8 Nos 3187
specification and drawing alongwith brackets &
accessories etc. (For all type of LED Retrofit)
Supply of 300 mm dia – signal LED retrofit -
Red (blow) with minimum light output 260Cd
95 RT- NATC 6.9 Nos 3089
and maximum power consumption 10W ±10%,
with IP-65 protection
Supply of 300 mm dia – signal aspect – LED
retrofit - Amber (blow) with minimum light
96 RT- NATC 6.10 Nos 3089
output 260Cd and maximum power
consumption 10W±10%, with IP-65 protection

Supply of 300 mm dia – signal aspect – LED


retrofit - Green (arrow/U- Turn) with minimum
97 RT- NATC 6.11 Nos 3461
light output 100Cd and maximum power
consumption 4W±10%, with IP-65 protection

Supply of 300 mm dia – signal aspect – LED


retrofit - Red (ped. standing) with minimum
98 RT- NATC 6.12 Nos 2541
light output 65Cd and maximum power
consumption 4W±10%,with IP-65 protection

Supply of 300 mm dia – single aspect – LED


retrofit - Green (ped.walking) with minimum
99 RT- NATC 6.13 Nos 3598
light output 45Cd and maximum power
consumption 4W±10%,with IP-65 protection

Supply of 300 mm dia – signal aspect – LED


retrofit - Amber (arrow) with minimum light
100 RT- NATC 6.14 Nos 2762
output 100Cd and maximum power
consumption 4W±10%,with IP-65 protection
Installation of Polycarbonate LED Signal
101 RT- ATC 6.15 aspect of 300 mm dia. on standard traffic Nos 312
signal straight pole
Installation of Polycarbonate LED Signal
102 RT- ATC 6.16 aspect of 300 mm dia. On standard traffic Nos 624
signal cantilever pole
Removal of Polycarbonate LED Signal aspect
103 RT- ATC 6.17 of 300 mm dia. on standard traffic signal Nos 312
straight pole
Removal of Polycarbonate LED Signal aspect
104 RT- ATC 6.18 of 300 mm dia. On standard traffic signal Nos 567
cantilever pole
7 RT-7 Cables
Supply of following 650/1100 volt grade PVC
insulated PVC sheathed multicore copper
conductor armoured cables as per
specification & IS 1554 part I in existing
trenches, ducts, GI pipes
105 RT- ATC 7.1 1.5 Sq.mm. 2 core copper conductor Mtrs 62
106 RT- ATC 7.2 2.5 Sq.mm. 3 core copper conductor Mtrs 105
107 RT- ATC 7.3 1 Sq.mm. 8 core copper conductor Mtrs 156
108 RT- ATC 7.4 1.5 Sq.mm. 8 core copper conductor Mtrs 156

7
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
109 RT- ATC 7.5 1 Sq.mm. 16 core copper conductor Mtrs 275
110 RT- ATC 7.6 1.5 Sq.mm. 16 core copper conductor Mtrs 275
111 RT- ATC 7.7 1.5 Sq.mm. 30 core copper conductor Mtrs 480
112 RT- ATC 7.8 1.5 Sq.mm. 2 Pair copper conductor Mtrs 237
113 RT- ATC 7.9 Supply of CAT-6 cable for CCTV application Mtrs 24
114 RT- ATC 7.10 Supply of OFC 6 Core Mtrs 47
115 RT- ATC 7.11 Splicing of OFC Cable (Per pair) Nos 284
116 RT- ATC 7.12 Patch Cord for OFC cable Nos 284
117 RT- ATC 7.13 Installation of CAT-6 cable Mtrs 17
Laying of signal cables (all types including
communication cables with multi pairs as
118 RT- ATC 7.14 described above) in trenches, existing ducts / Mtrs 30
G.I. Pipes including ferruling, testing etc. but
excluding any cable joint, excavation etc.

Relaying of signal cables (all types including


communication cables with multi pairs as
119 RT- ATC 7.15 described above) in existing trenches, ducts / Mtrs 23
G.I. Pipes including ferruling, testing etc. but
excluding any cable joint, excavation etc.

Removal of signal cables (all types including


communication cables with multi pairs as
120 RT- ATC 7.16 described above) in existing trenches, ducts / Mtrs 20
G.I. Pipes including ferruling, testing etc. but
excluding any cable joint, excavation etc.
Supply of cable jointing Kit and joining of 1.5
121 RT- NATC 7.17 Nos 1784
sq.mm copper conductor control cable
Supply of cable jointing Kit and joining of 2.5
122 RT- NATC 7.18 Nos 1863
Sq.mm. 3 Core copper conductor control cable
Supply of cable jointing Kit (IP 68
123 RT- ATC 7.19 Enclosure) and joining of 1 Sq.mm. 8 core Nos 2423
copper conductor control cable
Supply of cable jointing Kit and joining of 1.5
124 RT- NATC 7.20 Nos 1152
Sq.mm. 8 core copper conductor control cable

Supply of cable jointing Kit (IP 68


125 RT- ATC 7.21 Enclosure) and joining of 1 Sq.mm. 16 core Nos 3770
copper conductor control cable
Supply of cable jointing Kit and joining of 1.5
126 RT- NATC 7.22 Sq.mm. 16 core copper conductor control Nos 1310
cable
Supply of cable jointing Kit and joining of 1.5
127 RT- NATC 7.23 Sq.mm. 30 core copper conductor control Nos 1705
cable
Supply of cable jointing Kit and joining of 1.5
128 RT- ATC 7.24 Sq.mm. 2 Pair copper conductor cable (IP68 Nos 2140
Enclosure)

8
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
8 RT-8 Flashers
Supply of Blinker Controller with adjustable
flash rate having interface to solar panel of 12
129 RT- NATC 8.1 Volts D.C. supply with sufficient power rating Nos 5211
with battery charge regulator (without battery,
cabinet and Solar Panel)
Installation, testing & commissioning of above
flasher unit (solar Blinker Controller) excluding
130 RT- NATC 8.2 Nos 653
foundation, installation of cabinet, battery,
panel etc.
131 RT- NATC 8.3 Supply of Solar Panel 12V / 50 Watt Nos 5685
132 RT- NATC 8.4 Supply of Solar Panel 12V / 70Watt Nos 7959
133 RT- NATC 8.5 Supply of Solar Panel 12V / 100 Watt Nos 14212
134 RT- NATC 8.6 Supply of Solar Panel 12V / 150 Watt Nos 17055
135 RT- NATC 8.7 Supply of Battery 12V / 50 AH Nos 7185
136 RT- NATC 8.8 Supply of Battery 12V / 65 AH Nos 7185
137 RT- NATC 8.9 Supply of Battery 12V / 100 AH Nos 9256
138 RT- NATC 8.10 Supply of Battery 12V / 150 AH Nos 16700
Supply of solar battery cabinet suitable for 50
139 RT- NATC 8.11 Nos 4634
AH Battery.
Supply of solar battery cabinet suitable for 65
140 RT- NATC 8.12 Nos 4634
AH Battery.
Supply of solar battery cabinet suitable for 100
141 RT- NATC 8.13 Nos 4634
AH Battery.
Supply of solar battery cabinet suitable for 150
142 RT- NATC 8.14 Nos 7283
AH Battery.
Installation, testing and commissioning of all
143 RT- NATC 8.15 Nos 1362
types of solar Panel as described above.
Removal of already installed solar panel as
144 RT- NATC 8.16 Nos 613
described above
Installation, testing and commissioning of
145 RT- NATC 8.17 Nos 511
batteries as described above.
Removal of already installed batteries as
146 RT- NATC 8.18 Nos 511
described above.
Installation, testing and commissioning of all
147 RT- NATC 8.19 types of solar battery cabinet as described Nos 511
above.
Removal of already installed solar battery
148 RT- NATC 8.20 Nos 511
cabinet as described above including battery.
Vehicle Detector Camera- Traficam/FLIR
9 RT-9
Camera
Traficam Wide Angle Lens (Ref. No 10-6090) -
149 RT- ATC 9.1 Camera for Vehicle detection system, Black & Nos 102068
White
Traficam Narrow Angle Lens (Ref. No 10-
150 RT- ATC 9.2 6091) - Camera for Vehicle detection system, Nos 102068
Black & White
TrafiCam X-stream BPL version, wide angle
151 RT- ATC 9.3 (Ref. No 10-6040)- Camera for Vehicle Nos 158636
detection system, Coloured
TrafiCam X-stream BPL Version, narrow angle
152 RT- ATC 9.4 (Ref. No 10-6041)-Camera for Vehicle Nos 158636
detection system, Coloured

9
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Traficam X-Stream BPL with HTTP streaming
153 RT- ATC 9.5 video (Ref No. 10-7000) Wide Angle, Presence Nos 158636
& Data collection
Traficam X-Stream BPL with HTTP streaming
154 RT- ATC 9.6 video (Ref No. 10-7001) Narrow Angle, Nos 158636
Presence & Data collection
155 RT- ATC 9.7 1TI - 4 outputs (Ref. No 10-6028) Nos 18446
156 RT- ATC 9.8 4TI - 16 outputs (Ref. No 19-6027) Nos 30129
157 RT- ATC 9.9 Ethernet interface (Ref. No 10-6070) Nos 7378
TI x-stream BPL - 16 outputs (Ref. No 10-
158 RT- ATC 9.10 Nos 61487
6045)
TI xp. BPL - expansion board (Ref. No 10-
159 RT- ATC 9.11 Nos 24595
6044)
160 RT- ATC 9.12 Power Supply Unit (24V-48V AC/DC ) Nos 3689
FLUX , 1 server license of the Traficon
161 RT- ATC 9.13 Nos 614869
Management Software (Ref. No- 10-0076)
IMUX , 1 server license of the Traficon
162 RT- ATC 9.14 Nos 614869
streaming server (Ref. No- 10-0086)
Traficon Engineer's On Site Support Charges
per day, excluding additional travel expenses
163 RT- ATC 9.15 Nos 45248
i.e. hotel, flights, meals and local transport at
actuals (to be borne by the customer)
Preventive and Corrective maintace of vehicle
164 RT- ATC 9.15A detector cameras per cameras as per Nos 596
Technical specifications
10 RT-10 Control Room Related
Supply, installation, testing and commissioning
of 3 kVA UPS along with batteries providing 30
165 RT- ATC 10.1 Nos 63938
minutes back up for 3 kVA UPS including MS
powder quoted battery rack

Supply, installation, testing and commissioning


of 5 kVA UPS along with batteries providing 30
166 RT- ATC 10.2 Nos 156879
minutes back up for 5 kVA UPS including MS
powder quoted battery rack

Supply, installation, testing and commissioning


of 8 kVA UPS along with batteries providing 30
167 RT- ATC 10.3 Nos 225429
minutes back up for 8 kVA UPS including MS
powder quoted battery rack

Supply, installation, testing and commissioning


of 10 kVA UPS along with batteries providing
168 RT- ATC 10.4 Nos 225429
30 minutes back up for 10 kVA UPS including
MS powder quoted battery rack

Supply, installation, testing and commissioning


of 10 kVA UPS along with batteries providing
169 RT- ATC 10.5 Nos 459926
120 minutes back up for 10 kVA UPS including
MS powder quoted battery rack
Supply, installation, testing and commissioning
170 RT- ATC 10.6 Nos 32919
of LAN Ethernet Switch
Removal of already installed LAN Ethernet
171 RT- ATC 10.7 Nos 113
Switch

10
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
172 RT- ATC 10.8 Supply & installation of System clock with GPS Nos 42088
Supply and installation of HP DESIGNJET
173 RT- ATC 10.9 Nos 355499
T790 44” E Plotter
174 RT- ATC 10.10 Supply and installation of HP Laserjet Printer Nos 7424
175 RT- ATC 10.11 Supply of HP Laser cartridge Nos 6708
176 RT- ATC 10.12 Supply of Xerox Phaser 3117 cartridge Nos 7925
177 RT- ATC 10.13 Supply of Plotter cartridge set HP Designjet Nos 13415
Supply & installation of PC upgrades additional
178 RT- ATC 10.14 Nos 6884
RAM
179 RT- ATC 10.15 Supply of Keyboard Nos 1973
180 RT- ATC 10.16 Supply of optical Mouse Nos 947
181 RT- ATC 10.17 Antivirus Renewal/updates Nos 2367
Server for ITACA - Supply of HP Proliant
DL580G5 Server, Product ID:-438087-421 or
182 RT- ATC 10.18 any HP/ IBM higher configuration (or Nos 685393
compatible with the said server) for 3 Years
24x7 Onsite Warranty
Server for CCTV HP ProLiant DL380p Gen8
(1) Intel® Xeon® E5-2643 (3.3GHz/
4-core/10MB/8 GT-s QPI/130 W) Processor/
10MB (1x10MB) Level 3/ 16 GB RAM PC3L-
10600R (DDR3-1333) Registered DIMMS/HP
183 RT- ATC 10.19 Nos 685393
Smart Array P420i/ZM (RAID 0/1/1+0)/ 8 SFF
SAS/SATA HDD Bays; includes 6 SFF hard
drive blanks/(1) HP 460W Common Slot Gold
Hot Plug Power Supply (92% Efficient)/ 3
Years 24x7 Onsite Warranty
Memory for CCTV - 1 TB SATA 2.5" HDD - For
184 RT- ATC 10.20 Nos 37579
archiver Server
185 RT- ATC 10.21 Supply & Installation of branded 2TR Split AC Nos 55144
Suppply of branded A4 size MFP (Printer,
186 RT- ATC 10.22 Nos 21133
Scanner, Copier)
Supply, intsallation of Operator terminal Intel
187 RT- ATC 10.23 Processor based PC with i5/i7 processor, 1TB Nos 90189
HDD, 4GB RAM, 17 inch LED Monitor

Supply, intsallation of HP Workstations Z220


188 RT- ATC 10.24 SFF/Intel i7/8 GB/500 GB/Win 8 64 Bit/1 GB Nos 112736
Graphic Card/3 Years Onsite Warranty
189 RT- ATC 10.25 Samsung 32" LED Screen Nos 42088
Supply of Canon iR 2018N A3 Digital Copier
190 RT- ATC 10.26 Nos 130079
with Network Printer
Telvent direct support for ITACA issues
191 RT- ATC 10.27 HOUR 26648
Remote support
Monthly Operation & Maint of Control Room as
192 RT- ATC 10.28 Nos 244275
per Tech Specification
Monthly Preventive & Corrective Maintenance
193 RT- ATC 10.29 of Optimus Server ITACA and Data Server as Nos 20726
per Tech Spec.
Monthly Preventive & Corrective Maintenance
194 RT- ATC 10.30 Nos 1480
of Operator Terminals

11
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Monthly Preventive & Corrective Maintenance
195 RT- ATC 10.31 Nos 1851
of Air Conditioner Spilt per unit

Monthly Preventive & Corrective Maintenance


196 RT- ATC 10.32 Nos 2813
of Air Conditioner Cassette per unit
Monthly Comprehensive Maintenance of Barco
197 RT- ATC 10.33 Nos 39972
Video Wall per Cube
Monthly Operation and Maintenance of MCGM
198 RT- ATC 10.34 Fault Management Centre as per Technical Nos 74023
Specification
Monthly Preventive and Corrective
199 RT- ATC 10.35 Nos 5922
Maintenance of FMS Server
Monthly Preventive and Corrective
200 RT- ATC 10.36 Maintenance of Operator terminals/Personal Nos 1628
Computer per unit
Monthly Preventive and Corrective
201 RT- ATC 10.37 Nos 3849
Comprehensive Maintenance of UPS per unit

Monthly Preventive and Corrective


202 RT- ATC 10.38 Nos 1480
maintenance of Scanner EPSON GT 15000

Monthly Preventive and Corrective


203 RT- ATC 10.39 Nos 2221
Maintenance of Plotter HP Designjet T6110-44

Monthly Preventive and Corrective


204 RT- ATC 10.40 Nos 252
Maintenance of HP Laserjet Printers per unit
Monthly Preventive and Corrective maint of
205 RT- ATC 10.41 Nos 1628
Laptops per unit
Supply of AC vehicle with driver, fuel and
206 RT- ATC 10.42 Per Day 2665
maintenance
Comprehensive Maint of Canon iR 2018N A3
207 RT- ATC 10.43 Digital copier, with Network Printer Nos 2517

Storage Depot Maintenance and Inventory


208 RT- ATC 10.44 Month 310895
Management as per Tech Specs
Providing and fixing cement sheets complete
209 RT- ATC 10.45 Sq. Feet 286
with wooden framework for Control Room

210 RT- ATC 10.46 Providing and fixing 2'x2' tiles for Control Room Sq. Feet 271

Providing and fixing copper refrigerant


pipework and AC units of max 2TR capacity,
211 RT- ATC 10.47 SET 90189
complete with clamping upto max length of 20
ft per set with insulation for Control Room
Providing and fixing glass windows
212 RT- ATC 10.48 (Aluminium sliding windows 3, x 4, size) for Nos 9770
Control Room
Providing and fixing roller blinds (size : 4' x 5')
213 RT- ATC 10.49 Nos 4810
for Control Room
Providing and installing 2TR capacity cassette
214 RT- ATC 10.50 Air conditioner, complete with 80' pipework for Nos 187894
Control Room
Providing and fixing supporting stand for
215 RT- ATC 10.51 Nos 12025
conference main table for Control Room
216 RT- ATC 10.52 Internal plastic paint Sq. Feet 33

12
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Strengthening of existing of false ceiling grid
217 RT- ATC 10.53 Sq. Feet 23
with new support and fastner for Control Room
Providing and fixing Alternative with water
218 RT- ATC 10.54 Resistant ceiling tiles of 2’X2’ size made of Sq. Feet 90
PVC for Control Room
Replacement of uphoistry including required
219 RT- ATC 10.55 Nos 1901
foam of 32 D (high density) for chair
Replacement of pair of handle (SS finish with
220 RT- ATC 10.56 Nos 1253
PU pad) (per pair - 2 Nos) for chair
Replacement of synchro mechanism (with 1
221 RT- ATC 10.57 Nos 1426
year warranty)
Replacement of custors. (Wheels) Nylon
222 RT- ATC 10.58 Nos 86
material for chair
Replacment of gaslift (1Year warranty) for
223 RT- ATC 10.59 Nos 778
chair
224 RT- ATC 10.60 Replacement of Stand (PP) for chair Nos 778
Providing new chair with gas lift handle to
225 RT- ATC 10.61 Nos 5712
match with existing design of chair
Replacement of raised floor tiles (laminated) 2'
226 RT- ATC 10.62 x 2' size to match with existing tiles on existing Nos 2856
stringes and studs
227 RT- ATC 10.63 Dust mat carpet Sq. Feet 210
228 RT- ATC 10.64 Audit of ITACA System on quarterly basis Nos 1345845
Rent for 12 Mtr Maclifton for CCTV and Video
229 RT- ATC 10.65 Shift 8809
Detection Cameras per shift ( 8 hrs Shift)
Supply, Installation and Commissioning of
Video Wall
Video Wall diagonal Size 50 Inch (Equivalent to
230 RT- ATC 10.66 Nos 1169373
Planar make model no - P50X-LED-AG-D)

Video Wall diagonal Size 50 Inch (Equivalent to


231 RT- ATC 10.67 Nos 1244332
Planar make model no - P50X-LED-AG-V)

Video Wall diagonal Size 50 Inch (Equivalent to


232 RT- ATC 10.68 Nos 1754059
Planar make model no - P50HD-LED-AG-D)

Video Wall diagonal Size 50 Inch (Equivalent to


233 RT- ATC 10.69 Nos 1829019
Planar make model no - P50HD-LED-AG-V)

Video Wall diagonal Size 50 Inch (Equivalent to


234 RT- ATC 10.70 Nos 1604139
Planar make model no - P50S-LED-AG-D)

Video Wall diagonal Size 50 Inch (Equivalent to


235 RT- ATC 10.71 Nos 1679099
Planar make model no - P50S-LED-AG-V)

Video Wall diagonal Size 60 Inch (Equivalent to


236 RT- ATC 10.72 Nos 1799035
Planar make model no - P60HD-LED-AG-D)

Video Wall diagonal Size 60 Inch (Equivalent to


237 RT- ATC 10.73 Nos 1873994
Planar make model no - P60HD-LED-AG-V)

Video Wall diagonal Size 67 Inch (Equivalent to


238 RT- ATC 10.74 Nos 1244332
Planar make model no - P67X-LED-AG-D)

13
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Video Wall diagonal Size 67 Inch (Equivalent to
239 RT- ATC 10.75 Nos 1319292
Planar make model no - P67X-LED-AG-V)

Video Wall diagonal Size 67 Inch (Equivalent to


240 RT- ATC 10.76 Nos 1679099
Planar make model no - P67S-LED-AG-D)

Video Wall diagonal Size 67 Inch (Equivalent to


241 RT- ATC 10.77 Nos 1754059
Planar make model no - P67S-LED-AG-V)

Video Wall diagonal Size 70 Inch (Equivalent to


242 RT- ATC 10.78 Nos 1903978
Planar make model no - P70HD-LED-AG-D)

Video Wall diagonal Size 70 Inch (Equivalent to


243 RT- ATC 10.79 Nos 1978938
Planar make model no - P70HD-LED-AG-V)

Video Wall diagonal Size 80 Inch (Equivalent to


244 RT- ATC 10.80 Nos 1739067
Planar make model no - P80S-LED-AG-D)

Video Wall diagonal Size 80 Inch (Equivalent to


245 RT- ATC 10.81 Nos 1814027
Planar make model no - P80S-LED-AG-V)

Video Wall diagonal Size 84 Inch (Equivalent to


246 RT- ATC 10.82 Nos 1993930
Planar make model no - P84S-LED-AG-D)

Video Wall diagonal Size 84 Inch (Equivalent to


247 RT- ATC 10.83 Nos 2053898
Planar make model no - P84S-LED-AG-V)

Traffic data warehouse: Onetime setup with


servers [minimum 5], Operating system,
Network, interfacing with various outdoor traffic
248 RT- ATC 10.84 Nos 3826561
sensors, traffic data collection, traffic data
processing and fusion, traffic data
dissemination, UI and reporting
11 RT-11 CCTV Camera
Supply of Outdoor, Colour IP minimum 28x
Optical and 10 X Digital Pan Tilt Zoom
Integrated Dome Network Camera. Multiple,
individually configurable MPEG4 and Motion
249 RT- ATC 11.1 Nos 165097
JPEG streams; High Resolution 4 CIF/30 fps.
Operation in -34°C to +50°C including master
recorder software , camera review licence and
per camera licence required

Installation, testing and commissioning of


Outdoor, Colour IP minimum 28x Optical and
250 RT- ATC 11.2 10 X Digital Pan Tilt Zoom Integrated Dome Nos 8511
Network Camera as mentioned above along
with extension arm, if required.
Removal and Re-Installation of camera as
251 RT- ATC 11.3 described above including brackets fixing, Nos 6242
cabling, configuration etc all complete
Supply, Installation and commissioning of
252 RT- ATC 11.4 extention arm of 1000mm for CCTV camera Nos 1574
(As per drawing )

14
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply, Installation and commissioning of
253 RT- ATC 11.5 extention arm of 300mm for CCTV camera Nos 1102
(As per drawing)
Supply of Nextiva Master recorder software
254 RT- ATC 11.6 with per camera review license and per camera Nos 2526192
license.
Installation, testing and commissioning of
255 RT- ATC 11.7 Nextiva 6.1 Master recorder software with per Nos 229521
camera review license and per camera license.

256 RT- ATC 11.8 Quarterly CCTV cleaning cost per camera Nos 248

Monthly Preventive and Corrective


257 RT- ATC 11.9 Nos 2610
Maintenance of per CCTV/ANPR of camera

258 RT- ATC 11.10 CCTV Server Maintenance Yearly Nos 143557

259 RT- ATC 11.11 Junction box with accessories as per drawing Nos 11619
260 RT- ATC 11.12 Verint Encoder Nos 30172
261 RT- ATC 11.13 Ethernet Switch for CCTV Nos 11244
262 RT- ATC 11.14 VGA Cable with connectors MTR 157
Emergency Vehicle (one vehicle with team and
263 RT- ATC 11.15 tools) Monthly cost to be operated as per Nos 163133
instruction of Engineer
Technical Suport in TPHQ/ Disaster Control
264 RT- ATC 11.16 Nos 66558
Room per shift
Supply of Automatic Number Plate Recognition
265 RT-ATC 11.17 Camera (Infra-red) with remote PTZ and Nos 156466
zoom/focus
SITC of Speed and vehicle classification radar
266 RT-ATC 11.18 Nos 78358
sensor
267 RT-ATC 11.19 SITC of Additional illuminator for ANPR Nos 39777
SITC of ANPR license with Processing Unit
268 RT-ATC 11.20 Nos 83449
with Central Control Software
SITC of Road side processing unit with
Processor, storage, communication modem,
269 RT-ATC 11.21 Nos 198886
battery charger, watch dog module and IP66
casing, cabling, mounting brackets and fixtures
SITC of Backup battery [12 V] for ANPR
270 RT-ATC 11.22 Nos 11126
Camera
12 RT-12 Variable Messaging Signboards
As per EN 12966 of size 2.88 mtrs x 1.44 mtrs
display area ( outer cabinet size of 3.18 x 1.74
271 RT- ATC 12.1 mtrs) 20mm pitch , Red Amber dual color full Nos 1241597
graphic display with 2 years warranty & 15
years life
As per EN 12966of size 2.88 mtrs x 1.44 mtrs
display area ( outer cabinet size of 3.18 x 1.74
272 RT- ATC 12.2 Nos 1314632
mtrs) 20mm pitch , full color full graphic display
with 2years warranty & 15 years life
Basis VMS control remote web based control
273 RT- ATC 12.3 Nos 607755
center software for 50 Users

15
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Graphical user Interface ( GUI ) map based
274 RT- ATC 12.4 VMS control center web based software for 50 Nos 2604664
Users with ITS connectivity features ( optional )
Supply of VMS pole assembly as pec ATC
275 RT- ATC 12.5 Nos 254892
Tech specifications as per & drawing
Supply of VMS gantry assembly as pec ATC
276 RT- ATC 12.6 Nos 269479
Tech specifications as per & drawing
277 RT- ATC 12.7 Removal of VMS and its assembly Nos 31775
278 RT- ATC 12.8 Removal of VMS pole / Gantry its assembly Nos 39719
Integration of Travel time information system
279 RT- ATC 12.9 Nos 1702254
with ATC Itaca software
Monthly Preventive & Corrective Maintenance
280 RT- ATC 12.10 of VMS and its travel time accessories per Nos 10000
VMS
SITC of Blue traffic Sensor with IP 67 casing,
281 RT- ATC 12.11 mounting brackets, power cable and Nos 202780
accessories and battery charger module
SITC of Traffic data warehouse system with
282 RT- ATC 12.12 Nos 3470038
VMS interface and system support
SITC of Server hardware, Operating system
283 RT- ATC 12.13 and network setup for upto 15 cameras / travel Nos 210311
time information application.

Preventive & Corrective Maintenance, SITC


13 RT-13
of Junctions & Miscellaneous Items
Lumpsum charges per signal for Monthly
284 RT- NATC 13.1 Preventive & Corrective Maintenance of Road Nos 7944
Traffic Signals – Isolated junctions.
Lumpsum charges per Flashing Beacon (non
285 RT- NATC 13.2 solar) for Monthly Preventive & Corrective Nos 567
Maintenance of Flashing Beacons.
Lumpsum charges per Flashing Beacon (solar)
286 RT- NATC 13.3 for Monthly Preventive & Corrective Nos 709
Maintenance of Flashing Beacons.
Supply, installation, Testing & commissioning
287 RT- NATC 13.4 alongwith an arrangement for Power supply, a Nos 1940239
typical 4-arm junction complete in all respect

Supply, installation, Testing & commissioning


288 RT- NATC 13.5 alongwith an arrangement for Power supply, a Nos 1455179
typical 3-arm junction complete in all respect
Supply, installation, Testing & commissioning
alongwith an arrangement for Power supply, a
289 RT- NATC 13.6 Nos 970120
typical pedestrian crossing junction complete in
all respect
Supply, installation, Testing & commissioning a
290 RT- NATC 13.7 typical 3-arm flashing beacon (solar) complete Nos 158747
in all respect

16
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply, installation, Testing & commissioning a
291 RT- NATC 13.8 typical pedestrian crossing flashing beacon Nos 105831
(solar) complete in all respect
Painting of Signal Junction Hardware (Non
292 RT- NATC 13.9 Nos 5107
ATC)
293 RT- NATC 13.10 Monthly Cleaning of Signal Junction. Nos 2837
Lump sum charges per signal for Monthly
294 RT- NATC 13.11 Preventive & Corrective Maintenance of Road Nos 6376
Traffic Signals (ATC)
Review of Signal Junction with proper Traffic
Engineering and Changing Cycle Time, Phase,
295 RT- NATC 13.12 Nos 156607
Plan etc. in co-ordination with Traffic Police
and MCGM Engineer once in a year
Creation of input for junction in ITACA, link
296 RT- ATC 13.13 calibration and system validation complete in Nos 25449
all for each junction
NOTE: 1)Installation & removal of all items include transportation cost of items from store to site, Breaker
2) Traficam (the product of M/s. Traficon N.V, Belgium) was the make specific for vehicle
3) M/s.Telvent has now been acquired by M/s. Schneider Electric Infrastructure Ltd.
RT-14 Civil Works
Supply & application of primer to the Road
Traffic Signal Controller foundation two coats
297 RT-14.1 Nos 151.00
as per technical specification.

Supply & application of the yellow & purple


coloured strips to the Controller foundation of
298 RT-14.2 Nos 980.00
Road Traffic Signal Controller as per technical
Specification and drawing no. RT.14.2.
Supply & painting of Junction Name,
junction Number, no sticking of bills with Black
Paint to the Road Traffic Signal Controller
299 RT-14.3 Nos 217.00
cabinet of M.S. material as per Technical
Specification and drawing no. RT.14.2 &
RT.14.3.
Painting Junction Number, Meter
Number/consumer number etc with Black Paint
300 RT-14.4 to the Road Traffic Signal Controller Power Nos 189.00
supply box of M.S. material as per Technical
Specification.
Supply & painting of Junction Name,
Installation Number, no sticking of bills etc with
Carving letters on Green colour retro-reflective
sheeting of approved make vide MORTH
301 RT-14.5 Nos 508.00
specification and as per MCGM Technical
Specification and drawing no. RT.14.2 &
RT.14.3 to the Road Traffic Signal Controller
cabinet.

17
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Painting Junction Number, Meter Number etc
with Carving letters on Green colour retro-
reflective sheeting of approved make vide
302 RT-14.6 MORTH specification and as per MCGM Nos 452.00
Technical Specification and drawing no.
RT.14.2 & RT.14.3. to the Road Traffic Signal
Controller Power supply box.
Supply & painting of yellow coloured circles on
straight poles & cantilever poles as per
303 RT-14.7 Nos 86.00
technical specification and drawing no.
RT.14.5 & RT.14.6.
Supply & Painting of pole numbers to the Road
Traffic Signal poles in the yellow circle with
304 RT-14.8 Nos 110.00
black paint as per technical specification and
drawing no. RT.14.5 & RT.14.6.
Supply & Painting controller cabinet with two
coats of synthetic enamel paint over a coat of
305 RT-14.9 Zinc chromate primer as per technical Nos 661.00
specification and directions of the Engineer-in-
Charge.
Supply & Painting power supply box cabinet
with two coats of synthetic enamel paint over a
306 RT-14.10 coat of Zinc chromate primer as per technical Nos 447.00
specification and directions of the Engineer-in-
Charge.
Supply & Painting straight pole with two coats
of synthetic enamel paint over a coat of Zinc
307 RT-14.11 Nos 333.00
chromate primer as per technical specification
and directions of the Engineer-in-Charge.
Supply & Painting cantilever pole with two
coats of synthetic enamel paint over a coat of
308 RT-14.12 Zinc chromate primer as per technical Nos 954.00
specification and directions of the Engineer-in-
Charge.
Excavation of trench for traffic signals and
VMS boards cables and conduiting as per
requirement of the signal junction up to the
depth of 1000mm below the ground surface
309 RT-14.13 Cum 2000.00
and width 500mm in the Carriage way (Asphalt/
Mastic Asphalt/ paver block) including refilling
of the trench in carriage way and removal of
debris as per the MCGM guidelines.
Excavation of trench for traffic signals and
VMS boards cables and conduiting as per
requirement of the signal junction up to the
depth of 1000mm below the ground surface
310 RT-14.14 Cum 3500.00
and width 500mm in the Carriage way (Cement
Concrete) including refilling of the trench in
carriage way and removal of debris as per the
MCGM guidelines.

18
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Excavation of trench for traffic signals and
VMS boards cables and conduiting as per
requirement of the signal junction up to the
depth of 600mm below the ground surface and
311 RT-14.15 Cum 1200.00
width 500mm in the footpath/soft soil including
refilling of the trench in footpath and removal of
debris as per the MCGM guidelines.

Cutting of two rows RCC/PQC carriageway


slabs upto slab depth by special RCC Cutting
312 RT-14.16 Rmt 5290.00
machine (Diamond Cutter) for laying duct with
double cut.
Excavate and install brick built or equivalent
sectional chamber to be 450mm (L)X 450mm
(B) X 600 mm(D) to tie into proposed 120 mm
313 RT-14.17 ducts/65mm G.I.Pipe in footpath include Nos 9375.00
permanent reinstatement and backfill material
as per MCGM technical specification and
drawing no. RT.14.17.

Excavate and install brick built or equivalent


sectional chamber to be 450mmX 450mmX
1000 mm to tie into proposed 120 mm
314 RT-14.18 ducts/65mm G.I.Pipe in footpath include Nos 10875.00
permanent reinstatement and backfill material
as per MCGM technical specification and
drawing no. RT.14.17.

Excavate and install brick built or equivalent


sectional chamber to be 560mm (L)X 450mm
(B) X 600 mm(D) to tie into proposed 120 mm
315 RT-14.19 ducts/65mm G.I.Pipe in footpath include Nos 9875.00
permanent reinstatement and backfill material
as per MCGM technical specification and
drawing no. RT.14.19

Excavate and install brick built or equivalent


sectional chamber to be 560mm (L)X 450mm
(B) X 1000 mm(D) to tie into proposed 120 mm
316 RT-14.20 ducts/65mm G.I.Pipe in footpath include Nos 11250.00
permanent reinstatement and backfill material
as per MCGM technical specification and
drawing no. RT.14.19

Supply and installation of FRP chamber cover


without frame 510mm (L)X 510mm (B) X
317 RT-14.21 Nos 5053.00
35mm thick as per EN 124 grade B to take
load 12.5 MT as per drawing no. RT.14.21

Supply and installation of FRP chamber cover


without frame 620mm (L)X 510mm (B) X
318 RT-14.22 Nos 5428.00
35mm thick as per EN 124 grade B to take
load 12.5 MT as per drawing no. RT.14.21

19
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supply and installation of M.S. chamber cover
frame to accommodate the chamber cover of
319 RT-14.23 Nos 821.00
size 510mm (L)X 510mm (B) X 35mm thick as
per drawing no. RT.14.23
Supply and installation of M.S. chamber cover
frame to accommodate the chamber cover of
320 RT-14.24 Nos 904.00
size 620mm (L)X 510mm (B) X 35mm thick as
per drawing no. RT.14.23
Erecting straight pole in pole foundation of
concrete M20 grade circular in shape of depth
321 RT-14.25 1.3m below and/or above ground level having Nos 6270.00
dia. Of 300mm only, as per technical
specification and drawing no. RT-14.25

Erecting cantilever pole in pole foundation of


concrete M20 grade circular in shape of depth
322 RT-14.26 1.3m below and/or above ground level having Nos 9797.00
dia. Of 450mm only, as per technical
specification and drawing no. RT-14.26
Providing and laying RCC foundation of
concrete M25 grade square in shape above
and below ground level and installation of
straight VMS gantry rested on foundation as
shown in drwg. and as per technical
323 RT-14.27 Nos 60016.00
specification.The rate shall also include cost of
excavation, centering, shuttering,
reinforcement, PCC 1:2:4, and grouting of
foundation bolt, etc. complete as per drawing
no. RT-ATC-12.5
Providing and laying RCC foundation of
concrete M25 grade square in shape above
and below ground level and installation of
cantilever VMS gantry rested on foundation as
shown in drwg. and as per technical
324 RT-14.28 Nos 72910.00
specification.The rate shall also include cost of
excavation, centering, shuttering,
reinforcement, PCC 1:2:4, and grouting of
foundation bolt, etc. complete as per drawing
no. RT-ATC-12.6
Installation and assembly of all camera poles
as per drawing in M20 C.C foundation (Ref no.
325 RT-14.29 Nos 5395.83
RT-14.29) (Excluding supply of pole and
related accessories)
Construction of signal controller foundation
upto 600mm height above ground level and
600 mm below ground level on C.C. M20 grade
pedestal, having size (LXBXH) with fixing of
326 RT-14.30 Nos 5980.32
SS304 nut bolts for controller cabinet & Power
supply box cabinet as per MCGM technical
specification and drawing no. RT-14.30
etc.complete

20
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Providing steel barricading as shown in
drawing no. RT-14.31 and details of material
used for fabricating are:
-GI pipe round/square 1- 1/2 " B grade
-GI pipe round/square 1 " B grade
327 RT-14.31 Nos 23325.00
-MS rod square & others
-1.6 mm GI sheet ( 1400 mm x 700 mm )
-3" dia wheel assembly -- 4 nos.
-Powder coating
with lettering.
NOTE: 1)Installation & removal of all items
include transportation cost of items from store
to site, Breaker cost, Maclifton cost, Crane cost
as applicable and transportation of removed
item from site to store.
15 DIVIDERS
Providing and fixing guard stone section 23 cm
x 23 cm x 75 cm fair dressed surface as
328 RT-15-01 specified and embedded in M-10 C.C bed Nos 491.00
20cm thick around, including two coasts of
white wash on exposed surfaces etc complete
Removing any type of c.c. tapered kerbs from
the existing island etc.& transporting the same
329 RT-15-02 Rmt 68.00
any where in the city & suburbs & stacking the
same nearby as directed
Providing / Laying C.C M10 in traffic island etc.
wherever necessary giving the appearance of
chequred tiles required with proper finish in
330 RT-15-03 Cum 4313.00
order to have a non slippery surface including
curing & vibrating by mechanical means etc.
complete as directed

Removing RCC parabolic dividers from the


331 RT-15-03-A road & transporting the same anywhere in Gr, Rmt 332.00
Mumbai limit, stacking the same as directed

Providing, casting and fixing (any where in city


or suburban limit) precast reinforced parabolic
dividers in C.C.M 25, Type-5 as per drg. No.
EET & C/Gen/013/03/Ty dt. 11.12.03 (Revised
on 15/06/06) including providing, bending,
fixing of reinforcement as per drawing, fixing
the dividers on site in C.M. 1:2 for cushioning
and jointing, filling the gap between dividers
332 RT-15-04 with C.C.M 15, curing, painting the exposed Rmt 4957.00
surface with road marking paint grade I (
confirming to IS- 164) in two coatss of
approved colour including excavation in road
portion and removing excavated material as
per direction any where in city or suburban
limit, cleaning the site etc. as directed by the
engineer, The rate is inclusive of all lift and
leads, transportation required for the work.

21
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Providing, casting, fixing (anywhere in city or
suburban limit) precast type 1 (both side
tapper) dividers in C.C.M 25 as per drg. No.
EET&C/Gen/013/03/ty dt. 11.12.03 (revised on
15-06-2006) including fixing the dividers on site
in C.M 1:2 for cushioning and jointing, curing,
painting the exposed surface with road
333 RT-15-05 marking paint grade I (Conforming to IS-164) Rmt 864.00
in two coats of approved colour, including
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit, cleaning the site etc as
directed by engineer ,The rate is inclusive of all
lift and leads, transportation required for the
work

Casting & supplying (any where in city or


suburban limit) precast type 1(both side tapper)
dividers in C.C.M 25 as per drg. No.
334 RT-15-06 EET&C/Gen/013/03/Ty dt. 11.12.03 (Revised Rmt 523.00
on 15/06/06) etc. as directed by the engineer.
The rate is inclusive of all lift & leads,
transportation required for the work.

Providing, casting, fixing (anywhere in city or


suburban limit) precast type 2(single side
tapper) dividers in C.C.M 25 as per drg. No.
EET&C/Gen/013/03/ty dt. 11.12.03 (revised on
15-06-2006) including fixing the dividers on site
in C.M 1:2 for cushioning and jointing, curing,
painting the exposed surface with road
335 RT-15-07 marking paint grade I (Conforming to IS-164) Rmt 665.00
in two coats of approved colour, including
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit, cleaning the site etc as
directed by engineer , The rate is inclusive of
all lift and leads, transportation required for the
work

Casting & supplying (any where in city or


suburban limit) precast type 2 (Single side
tapper) dividers in C.C.M 25 as per drg No.
336 RT-15-08 EET&C/Gen/013/03/Ty dt 11.12.03 (Revised Rmt 434.00
on 15/06/06) etc. as directed by the engineer.
The rate is inclusive of all lift & leads,
transportation required for the work.

22
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Providing, casting, fixing (anywhere in city or
suburban limit) type 4 ( Both side chamfered)
dividers in C.C.M 25 as per drg. No.
EET&C/Gen/013/03/ty dt. 11.12.03 (revised on
15-06-2006) including fixing the dividers on site
in C. C.M -10 for cushioning and jointing,
curing, painting the exposed surface with road
337 RT-15-09 marking paint grade I (Conforming to IS-164) Rmt 624.00
in two coats of approved colour, including
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit, cleaning the site etc as
directed by engineer, The rate is inclusive of all
lift and leads, transportation required for the
work

Fixing c.c tapered kerbs of type -1 as per Drg.


EET&C/Gen/013/03Ty dt 11.12.03(Revised on
15.06.2006) available on site in C.M 1:2
painting the exposed surface of the kerbs with
road marking paint grade-I ( confirming to IS-
164) in two coats of approved colour including
338 RT-15-10 Rmt 341.00
excavation in any material except rock /
concrete road and removing excavated
material as per direction any where in city or
suburban limit, cleaning the site etc as directed
by engineer , The rate is inclusive of all lift and
leads etc complete as directed

Fixing c.c tapered kerbs of type -2 as per Drg.


EET&C/Gen/013/03Ty dt 11.12.03(Revised on
15.06.2006) available on site in C.M 1:2
painting the exposed surface of the kerbs with
road marking paint grade-I ( confirming to IS-
164) in two coats of approved colour including
339 RT-15-11 Rmt 249.00
excavation in any material except rock /
concrete road and removing excavated
material as per direction any where in city or
suburban limit, cleaning the site etc as directed
by engineer , The rate is inclusive of all lift and
leads etc complete as directed

Fixing c.c tapered kerbs of type -3 as per Drg.


EET&C/Gen/013/03Ty dt 11.12.03(Revised on
15.06.2006) available on site in C.M 1:2
painting the exposed surface of the kerbs with
road marking paint grade-I ( confirming to IS-
164) in two coats of approved colour including
340 RT-15-12 Rmt 121.00
excavation in any material except rock /
concrete road and removing excavated
material as per direction any where in city or
suburban limit, cleaning the site etc as directed
by engineer , The rate is inclusive of all lift and
leads etc complete as directed

23
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Fixing c.c tapered kerbs of type -4 as per Drg.
EET&C/Gen/013/03Ty dt 11.12.03(Revised on
15.06.2006) available on site in C.M 1:2
painting the exposed surface of the kerbs with
road marking paint grade-I ( confirming to IS-
164) in two coats of approved colour including
341 RT-15-13 Rmt 214.00
excavation in any material except rock /
concrete road and removing excavated
material as per direction any where in city or
suburban limit, cleaning the site etc as directed
by engineer , The rate is inclusive of all lift and
leads etc complete as directed

Fixing R.C.C parabolic dividers, available on


site as per Drg . EET&C/Gen/013/03Ty dt
11.12.03 (Revised on 15.06.2006) painting the
exposed surface with road marking paint grade-
I ( confirming to IS- 164) in two coats of
approved colour including excavation in any
342 RT-15-14 Rmt 825.00
material except rock / concrete road and
removing excavated material as per direction
any where in city or suburban limit, cleaning the
site etc as directed by engineer , The rate is
inclusive of all lift and leads etc complete as
directed

Providing cast in situ tapering kerbs of C.C.M


25 type 1 on roads as per drg No.
EET&C/Gen/013/03Ty dt 11.12.03 (Revised on
15.06.2006) finished neatly with C.M 1:2
painting the exposed surface with two coats of
road marking paint grade-I ( confirming to IS-
343 RT-15-15 164) of approved colour and quality, including Rmt 757.00
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit cleaning the site etc as
directed by engineer ,The rate is inclusive of all
lift and leads, transportation required for the
work

Providing cast in situ tapering kerbs of C.C.M


25 type 2 on roads as per drg No.
EET&C/Gen/013/03Ty dt 11.12.03 (Revised on
15.06.2006) finished neatly with C.M 1:2
painting the exposed surface with two coats of
road marking paint grade-I ( confirming to IS-
344 RT-15-16 164) of approved colour and quality, including Rmt 585.00
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit cleaning the site etc as
directed by engineer ,The rate is inclusive of all
lift and leads, transportation required for the
work

24
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Providing cast in situ tapering kerbs of C.C.M
25 type 3 on roads as per drg No.
EET&C/Gen/013/03Ty dt 11.12.03 (Revised on
15.06.2006) finished neatly with C.M 1:2
painting the exposed surface with two coats of
road marking paint grade-I ( confirming to IS-
345 RT-15-17 164) of approved colour and quality, including Rmt 269.00
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit cleaning the site etc as
directed by engineer ,The rate is inclusive of all
lift and leads, transportation required for the
work

Providing cast in situ tapering kerbs of C.C.M


25 type 4 on roads as per drg No.
EET&C/Gen/013/03Ty dt 11.12.03 (Revised on
15.06.2006) finished neatly with C.M 1:2
painting the exposed surface with two coats of
road marking paint grade-I ( confirming to IS-
346 RT-15-18 164) of approved colour and quality, including Rmt 534.00
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit cleaning the site etc as
directed by engineer ,The rate is inclusive of all
lift and leads, transportation required for the
work

Providing, casting, fixing (anywhere in city or


suburban limit) type 3 ( C.C Studs) dividers in
C.C.M 25 as per drg. No.
EET&C/Gen/013/03/ty dt. 11.12.03 (revised on
15-06-2006) including fixing the dividers on site
in C. C.M -10 for cushioning and jointing,
curing, painting the exposed surface with road
347 RT-15-19 marking paint grade I (Conforming to IS-164) Rmt 308.00
in two coatss of approved colour, including
excavation in road portion and removing
excavated material as per direction any where
in city or suburban limit, cleaning the site etc as
directed by engineer, The rate is inclusive of all
lift and leads, transportation required for the
work

Casting & supplying (any where in city or


suburban limit) precast type 3 dividers in C.C.M
25 as per drg No. EET&C/Gen/013/03/Ty dt
348 RT-15-20 11.12.03 (Revised on 15/06/06) etc. as Rmt 180.00
directed by the engineer. The rate is inclusive
of all lift & leads, transportation required for the
work.

25
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Casting & supplying (any where in city or
suburban limit) precast type 4 dividers in C.C.M
25 as per drg No. EET&C/Gen/013/03/Ty dt
349 RT-15-21 11.12.03 (Revised on 15/06/06) etc. as Rmt 399.00
directed by the engineer. The rate is inclusive
of all lift & leads, transportation required for the
work.

16 SIGNAGE AND STREET FURNITURE


SQUARE PIPE RAILING

Providing and fabrication and fixing M.S. railing


of 10 Gauge,40mmX 40mm square pope
railing with 18mmX18 mm square intermediate
support, 65mm X 65mm square main supports
with M.S. pedestal (base -1type) and M.S.
cap- (type-1)including cutting, welding,
riveting, oil painting with navy blue colour or
350 RT-16-01 Rmt 3618.00
any other approved colour shads as directed
and fixing in cement concrete foundation as
shown vide Sr.No.2f-A1 in catalogue of Street
Furniture (Vol.I) published by M.C.G.M.
including removal of surplus material /debries
and restoring damaged portion of footpath, etc.
as directed. (without advertisement panel)

Add for providing Aluminium Pedestal and


351 RT-16-01-a Aluminium Caps in place M.S. Pedestal and Rmt 216.00
M.S. Cap if provided.
Add for providing FRP Pedestal and FRP Caps
352 RT-16-01-b in place of M.S. Pedestal and M.S. Cap if Rmt 431.00
provided
Add for application for Rusticide for removal of
rust and providing rust preventing treatment of
353 RT-16-01-c electrometric Alkaline Polymerie, rust Rmt 523.00
preventing solution as per Manufacturer’s
specification.
Add for providing advertisement panel for
354 RT-16-01-d Rmt 201.00
advertisement, If provided.
CIRCULAR PIPE RAILING

26
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

Providing and fabricating and fixing M.S. railing


of 10 Gauge, Dia. 40mm circular railing with
Dia. 18mm circular intermediate support, Dia.
65mm circular main supports with M.S.
pedestal (base-I-type) and M.S. cap-(type-I)
including cutting, welding, riveting oil painting
with navy blue colour or any other approved
355 RT-16-02 Rmt 3153.00
colour shades as directed and fixing in cement
concrete foundation as shown vide Sr.No.2F-
A1 in catalogue of street Furniture (Vol.I)
published by MCGM including removal of
surplus material/debris material. debries and
restoring damaged portion of footpath etc. as
directed (without advertisement panel)

Add for providing Aluminium Pedestal and


356 RT-16-02-a Aluminium Caps (in place of M.S. Pedestal Rmt 216.00
and M. S .Cap) if provided
Add for providing FRP Pedestal and FRP
357 RT-16-02-b Caps (in place of M.S. Pedestal and M.S.Cap) Rmt 431.00
if provided
Add for application of Rusticide for removal of
rust and providing rust preventing treatment of
358 RT-16-02-c elastomeric Alkaline Polymeric, rust Rmt 523.00
preventing solution as per Manufacturer’s
specification, If provided
Add for providing advertisement panel for
359 RT-16-02-d Rmt 201.00
advertisement, If provided.

Providing and fabrication and fixing Stainless


Steel railing of 10 Gauge of 304 grade
stainless steel having minimum nickel content
of 10% (laboratory testing certificate shall be
provided for used material) 40mm X 40mm
square pipe railing with 18mm X 18 mm square
intermediate support 65mm X 65mm square,
main support with stainless steel pedestal
360 RT-16-03 Rmt 11126.00
(base-I type) and stainless steel cap(type-I)
including cutting welding, riveting, polishing as
directed and fixing in cement concrete
foundation as shown vide Sr.No.2F-A1 in
catalogue of steel Furniture (Vol.I) published by
M.C.G.M. including removal of surplus
material/ debris and restoring damage portion
of footpath etc. as directed.

27
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

Providing and fabrication and fixing Stainless


Steel railing of 10 gauge of 304 grade stainless
steel having minimum nickel content of 10%
(laboratory testing certificate shall be provided
for used material), 40mmX40mm square pope
railing with 18mmX18mm square intermediate
support,65mmX65mm square main supports
with Stainless Steel pedestal (base-I type) and
361 RT-16-04 Rmt 11327.00
Stainless Steel cap- (type-I) including cutting,
welding, riveting, polishing as directed and
fixing in cement concrete foundation as shown
vide Sr.No.2F-A1 in catalogue of Street
Furniture (Vol.I) published by M.C.G.M
including removal of surplus material/debris
and restoring damaged portion. (footpath, etc.
directed (with advertisement panel)

Providing and fabrication and fixing Stainless


Steel railing of 10 gauge of 304 grade stainless
steel having minimum nickel content 10% (
Laboratory testing certificate shall be provided
for used material), dia. 40mm circular pipe
railing with dia. 18mm circular intermediate
support, dia. 65mm circular main supports with
Stainless Steel pedestal( base-I type) and
362 RT-16-05 Rmt 9306.00
Stainless Steel cap (type-I) including cutting,
welding, riveting, polishing as directed and
fixing in cement concrete foundation as shown
vide Sr.No.2F-A1 in catalogue of Street
Furniture (Vol.I) published by M.C.G.M.
including removal of surplus material/debries
and restoring damaged portion of footpath, etc.
as directed.

Providing and fabrication and fixing Stainless


Steel railing of 10 gauge of 304 grade stainless
steel having minimum nickel content 10% (
Laboratory testing certificate shall be provided
for used material) dia. 40mm circular pipe
railing with dia. 18mm circular intermediate
support, dia. 65mm circular main supports with
Stainless Steel pedestal( base-I type) and
363 RT-16-06 Rmt 9507.00
Stainless Steel cap (type-I) including cutting,
welding, riveting, polishing as directed and
fixing in cement concert foundation as shown
vide Sr.No.2F-A1 in catalogue of Street
Furniture (Vol.I) published by M.C.G.M.
including removal of surplus material/debries
and restoring damaged portion of footpath, etc.
as directed(with advertisement)

28
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Arrow marking for Route direction straight or
right or left or straight & right or straight or left
364 RT-16-07 & lettering as per design in white or traffic Each 933.00
yellow as specified and directed for speed limit
upto 50 km/hrs.
BOARD STREET NAME WITHOUT SIGN
BOARD
Street Name Board without sign board:
Providing, fabricating and erecting on site
Street Name Board (of type 2S-A-1) as per the
design incorporated in the catalogue of street
Furniture (Volume-II) Published by M.C.G.M.
Vertical pole shall be M.S. Square pipe of size
75mm x 75mm x 3.5mm thk. Signage plaque
(box) shall be of size 900mm x 600mm made
of M.S. angle frame of size 50mm x 50mm x
6mm thick covered with 3mm thk aluminum
sheet / F.R.P. Sheet on both sides. The
signage plaque assembly shall be fixed to the
vertical pole with 40mm x 10mm thk size MS
support plate. The traffic signboard of size
365 RT-16-08 Nos 19945.00
600mm dia shall be supported on M.S. support
pipe of size 50mm x50mm x 3mm. Traffic sign
board shall be made of 25mm x 25mm x 3mm
thick M.S. Sq. pipes covered with 3mm thk.
Aluminum sheet / F.R.P. sheet on both sides
as shown in the figure. The top open end of
the vertical pole shall be closed with M.S. plate
of size 75mm x 75mm x 3.5mm thick. Both the
boxes shall be pasted with HIGH INTENSITY
GRADE retro reflective base sheets on both
sides conforming to I.R.C. 67 CODE. Letters
or signages to be pasted on these boxes shall
also be of HIGH INTENSITY GRADE (upto
50% of basic area) conforming to I.R.C. 67
CODE. The reflectivity of sheet shall have

29
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Street Name Board without sign board:
Providing, fabricating and erecting on site
Street Name Board (of type 2S-A-1 and 2S-F)
As per the design incorporated in the catalogue
of street Furniture (Volume –II). Published by
M.C.G.M., Vertical pole shall be M.S. Square
pipe of size 75mm x 75mm x 3.5mm thick
Signage plaque (box) shall be of size 900mm x
600mm made of M.S. angle frame of size
50mm x 50mm x 6mm thick covered with 3mm
thk aluminum sheet / F.R.P. Sheet on both
sides, the box assembly; shall be fixed to the
vertical pole with 40mm x 10mm thick size MS
366 RT-16-09 support plate. The top open end of the vertical Nos 14237.00
pole shall be closed with MS Plate of size
75mm x 75mm x 3.5mm thick. The box shall
be pasted with HIGH INTENSITY GRADE retro
reflective base sheets on both sides
conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflective of sheet shall have guarantee of
7 years. The reflection count shall not be less
than 90% of its original reflection after 7 years
The base plate of the vertical pole shall be of
MS size 200mm x 200mm x 6mm thick
anchored with 16mm
Board Street Name dia.without
J Bolts in 1:2:4board:
sign
Providing, fabricating and erecting on site
Street Name Board (of type 2S-A-1 and 2S-F)
as per the design incorporated in the catalogue
of street Furniture (Volume-II). Published by
M.C.G.M. Vertical pole shall be M.S. Square
pipe of size 75mm x 75mm x 3.5mm thick.
Signage plaque (box) shall be of size 900mm x
600mm made of M.S. angle frame of size
50mm x 50mm x 6mm thick covered with 3mm
thick aluminum sheet / F.R.P. Sheet on both
sides, the box assembly; shall be fixed to the
vertical pole with 40mm x 10mm thick size MS
367 RT-16-10 support plate. The top open end of the vertical Nos 14905.00
pole shall be closed with MS plate of 75mm x
75mm x 3.5mm thick. The box shall be pasted
with HIGH INTENSITY GRADE retro reflective
base sheets on both sides conforming to I.R.C.
67 CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (upto 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectively of sheet
shall have guarantee of 7 years, the reflection
count shall not be less than 90% of its original
reflection after 7 years. The base plate of the
vertical pole shall be of MS of size 200mm x
200mm x 6mm thick anchored with 16mm dia.
368 J Bolts in 1:2:4 cement concrete with 2nos
BOLLARDS

30
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Bollards : Providing, fabricating and fixing M.S.
Square Bollards of 100mm x 100mm, 10
Gauge (of type 3F-A-1) as per the design
incorporated in the Catalogue of Street
Furniture (Vol-I) Published by MCGM, with
steel pedestal and steel cap as per designs (3F-
A1), (3F-A1.1), (3F-A1.2) and (3F-A1-3)
suitable to match the design adopted for
surrounding railing including cutting, welding,
reveting & polishing. The foundation shall
either be with base plate of 200 x 200 x 6mm
thick, 16 mm dia J Bolts or embedding pipe in
foundation by providing 20mm Dia x 6 nos
369 RT-16-11 holdfasts embedded in 1:2:4 concrete as Nos 5281.00
shown in drawing (3F-A1.1). The assembly
shall be treated with RustIcide solution of
approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as Per
Manufacture’s specifications and certificate) to
that effect shall be submitted along with
Guarantee Certificate), Further it shall be
painted with finish enamel paint, steel grey
colour (having 90% back content). The cost is
inclusive of making good the damage. Portion
of footpath and lining work with pavers blocks
and removing debris etc. complete as per
specifications and asfabricating
Bollards : Providing, directed byand
the fixing
Engineer.
M.S.
circular Bollards of 100mm dia, 100mm, 10
Gauge (of type 3F-A-1) as per the design
incorporated in the Catalogue of Street
Furniture (Vol-I) Published by MCGM, with
steel pedestal and steel cap as per designs (3F-
A.1), (3F-A1.1), (3F-A1.2) and (3F-A1-3)
suitable to match the design adopted for
surrounding railing including cutting, welding,
reveting, polishing. The foundation shall either
be with base plate of 200 x 200 x 6mm thick,
16 mm dia J Bolts or embedding pipe in
foundation by providing 20mm Dia x 6 nos
370 RT-16-12 holdfasts embedded in 1:2:4 concrete as Nos 4921.00
shown in drawing (3F-A1.1). The assembly
shall be treated with RustIcide solution of
approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as Per
Manufacture’s specifications and certificate to
that effect shall be submitted along with
Guarantee Certificate). Further it shall be
painted with matt finish enamel paint, steel
grey colour (having 90% back content). The
cost is inclusive of making good the damage
portion of footpath and lining work with pavers
blocks and removing debris etc. Complete as
per specifications and as directed by the

31
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

SQUARE PIPE Steel Bollards: Providing,


fabricating and fixing .Square Steel Bollards of,
100mm x 100mm, Square Steel Pipe (of type
3F-A-1) as per the design incorporated in the
Catalogue of Street Furniture (Vol-I) Published
by MCGM, made of 10 Guage, 304 quality
material with minimum nickel content not less
than 10% (laboratory testing certificate shall be
provided for used material) with stell pedestal
and steel cap as per designs (3F-A1), (3F-
A1.1), (3F-A1.2) and (3F-A1-3) suitable to
371 RT-16-13 match the design adopted for surrounding Nos 8479.00
railing including cutting, welding, riveting,
polishing. The foundation shall either be with
base plate of 200 x 200 x 6mm thk, 16 mm dia
J Bolts or embedding pipe in foundation by
providing 20mm Dia x 6 nos holdfasts
embedded in 1:2:4 concrete as shown in
drawing (3F-A1.1). inclusive of making good
the damage portion of footpath with matching
pavers blocks, tiles, removing debris etc.
Complete as per specifications and as directed
by the Engineer.

Circular Steel Bollards : Providing, fabricating


and fixing circular Steel Bollards of 100mm dia
circular Steel Pipe (of type 3F-A-1) as per the
design incorporated in the Catalogue of Street
Furniture (Vol-II). Published by MCGM, made
of 10 Guage, 304 quality material with
minimum nickel content not less than 10%
(laboratory testing certificate shall be provided
for used material) with steel pedestal and steel
cap as per designs (3F-A1), (3F-A1.1), (3F-
A1.2) and (3F-A1-3) suitable to match the
372 RT-16-14 Nos 7459.00
design adopted for surrounding railing including
cutting, welding, riveting, polishing. The
foundation shall either be with base plate of
200 x 200 x 6mm thick, 16 mm dia J Bolts or
embedding pipe in foundation by providing
20mm Dia x 6 nos holdfasts embedded in 1:2:4
concrete as shown in drawing (3F-A1.1).
inclusive of making good the damage portion
of footpath with matching pavers blocks, tiles
removing debris etc. complete as per
specifications and as directed by the Engineer.

32
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
JUNCTION NAME BOARD
Junction Name Board : Providing, fixing and
erecting on site Junction Name Board / Chowk
(of type 2S-D), as per the design incorporated
in the catalogue of street Furniture published
by M.C.G.M., Vertical pole shall be M.S.
Square pipe of size 100mm x 100mm x 3.5mm
thick. Signage plaque (box) shall be of size
900mm x 900mm made of M.S.L angle frame
of size 75mm x 75mm x 6mm thick covered
with 3mm thick aluminum sheet / F.R.P. Sheet
on both sides, the box assembly; shall be fixed
to the vertical pole with 40mm x 10mm thick
size MS support plate. The top open end of
373 RT-16-15 the vertical pole shall be closed with MS Plate Nos 27718.00
of size 100mm x 100mm x 3.5mm thick. The
box shall be pasted with HIGH INTENSITY
GRADE retro reflective base sheets on both
sides conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflective of sheet shall have guarantee of
7 years. The refection count shall not be less
than 90% of its original reflection after 7 years.
The foundation shall either be with base plate
of 200 x 200 x 6mm thick 16 mm dia J Bolts or
embedding pipe in foundation by providing
20mm DiaName
Junction x 6 nos hold fasts
Board: embedded
Providing, fixingin and
erecting on site Junction Name Board (of type
2S-E2) As per the design incorporated in the
catalogue of street Furniture published by
M.C.G.M., Vertical pole shall be M.S. Square
pipe of size 100mm x 100mm x 3.5mm thick.
Signage plaque (box) shall be of size 900mm x
900mm made of M.S.L angle frame of size
75mm x 75mm x 6mm thick covered with 3mm
thick aluminum sheet / F.R.P. Sheet on both
sides, the box assembly; shall be fixed to the
vertical pole with 40mm x 10mm thick size MS
support plate. The top open end of the vertical
374 RT-16-16 pole shall be closed with MS Plate of size Nos 26112.00
100mm x 100mm x 3.5mm thick. The box
shall be pasted with HIGH INTENSITY GRADE
retro reflective base sheets on both sides
conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflective of sheet shall have guarantee of
7 years. The refection count shall not be less
than 90% of its original reflection after 7 years.
The foundation shall either be with base plate
of 200 x 200 x 6mm thick 16 mm dia J Bolts or
embedding pipe in foundation by providing
20mm Dia x 6 nos hold fasts embedded in

33
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Junction Name Board : Providing, fixing and
erecting on site Junction Name Board (of type
2S-E1) as per the design incorporated in the
catalogue of street Furniture published by
M.C.G.M. Vertical pole shall be M.S. Square
pipe of size 100mm x 100mm x 3.5mm thick.
Signage plaque (box) shall be of size 900mm x
900mm made of M.S.L angle frame of size
75mm x 75mm x 6mm thick covered with 3mm
thick aluminum sheet / F.R.P. Sheet on both
sides, the box assembly; shall be fixed to the
vertical pole with 40mm x 10mm thick size MS
support plate. The top open end of the vertical
375 RT-16-17 pole shall be closed with MS Plate of size Nos 24492.00
100mm x 100mm x 3.5mm thick. The box
shall be pasted with HIGH INTENSITY GRADE
retro reflective base sheets on both sides
conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflective of sheet shall have guarantee of
7 years. The reflection count shall not be less
than 90% of its original reflection after 7 years.
The foundation shall either be with base plate
of 200 x 200 x 6mm thick 16 mm dia J Bolts or
embedding pipe in foundation by providing
20mm Dia x 6BOARD
DIRECTION nos hold fasts embedded in
Direction – Board – Providing, Fabricating,
Erecting on site Direction Board (of type 3S-
A2)(small-2) As per the design incorporated in
the catalogue of street Furniture published by
M.C.G.M., Vertical pole shall be ISMC-350.
Signage plaque (box) shall be of size 1200mm
x 2400mm made of ISMC 100mm and bracing
of MS angle 50mm x 50mm x 6mm, covered
with 3 mm aluminum sheet / F.R.P. Sheet on
both sides, the box assembly; shall be fixed to
the vertical pole. The box shall be pasted with
HIGH INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
376 RT-16-18 CODE. Letters or signages to be pasted on Nos 50631.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size 1500
mm x 1500mm as shown in drawing (3F-A1.1).
The assembly shall be treated with RustIcide
solution of approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as per
Manufactures specification and certificate to

34
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Direction – Board – Providing, Fabricating,
Erecting on site Direction Board (of type 3S-
A1) (SMALL) As per the design incorporated in
the catalogue of street Furniture published by
M.C.G.M., Vertical pole shall be ISMC-350,
Signage plaque (box) shall be of size 1200mm
x 2400mm made of ISMC 100mm and bracing
of MS angle 50mm x 50mm x 6mm, covered
with 3 mm aluminum sheet / F.R.P. Sheet on
both sides, the box assembly; shall be fixed to
the vertical pole. The box shall be pasted with
HIGH INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
377 RT-16-19 CODE. Letters or signages to be pasted on Nos 81794.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size 1500
mm x 1500mm as shown in drawing (3S-A1.1).
The assembly shall be treated with Rust-cide
solution of approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as per
Direction – Board
Manufactures – Providing,
specification and certificate to
Fabricating,
Erecting on site Direction Board (of type 3S-A-
2) (SMALL-1) As per the design incorporated
in the catalogue of street Furniture published
by M.C.G.M., Vertical pole shall be ISMC-350,
Signage plaque (box) shall be of size 900mm x
1800mm made of ISMC 100mm and bracing of
MS angle 50mm x 50mm x 6mm, covered with
3 mm aluminum sheet / F.R.P. Sheet on both
sides, the box assembly; shall be fixed to the
vertical pole. The box shall be pasted with
HIGH INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
378 RT-16-20 CODE. Letters or signages to be pasted on Nos 57149.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size
1500 mm x 1500mm as shown in drawing (3S-
A1.1). The assembly shall be treated with Rust-
cide solution of approved company and applied
with Polyurethane primer and Paint to resist
rusting of material (the treatment shall be given
as per Manufactures specification and

35
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Direction – Board – Providing, Fabricating,
Erecting on site Direction Board (of type 3S-
A1) (LARGE-1), as per the design incorporated
in the catalogue of street Furniture published
by M.C.G.M., Vertical pole shall be ISMC-350,
Signage plaque (box) shall be of size 1200mm
x 2400mm made of ISMC 100mm and bracing
of MS angle 50mm x 50mm x 6mm, covered
with 3 mm thick aluminum sheet / F.R.P. Sheet
on both sides, the box assembly; shall be fixed
to the vertical pole. The box shall be pasted
with HIGH INTENSITY GRADE retro reflective
base sheets on both sides conforming to I.R.C.
379 RT-16-21 67 CODE. Letters or signages to be pasted on Nos 76997.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size 1500
mm x 1500mm as shown in drawing (3S-A1.1).
The assembly shall be treated with RustIcide
solution of approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as per
Manufactures specification
Direction – Board and certificate
– Providing, to
Fabricating,
Erecting on site Direction Board (of type 3S-
A1) (LARGE-2), as per the design incorporated
in the catalogue of street Furniture published
by M.C.G.M., Vertical pole shall be ISMC-350.
Signage plaque (box) shall be of size 1200mm
x 1800mm made of ISMC 100mm and bracing
of MS angle 50mm x 50mm x 6mm, covered
with 3 mm aluminum sheet / F.R.P. Sheet on
both sides, the box assembly; shall be fixed to
the vertical pole. The box shall be pasted with
HIGH INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
380 RT-16-22 CODE. Letters or signages to be pasted on Nos 64275.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The refection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size 1500
mm x 1500mm as shown in drawing (3S-A1.1).
The assembly shall be treated with RustIcide
solution of approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as per
Manufactures specification and certificate to

36
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Direction – Board – Providing, Fabricating,
Erecting on site Direction Board (of type 3S-
A2) (LARGE-1) as per the design incorporated
in the catalogue of street Furniture published
by M.C.G.M., Vertical pole shall be ISMC-350.
Signage plaque (box) shall be of size 1200mm
x 2400mm made of ISMC 100mm and bracing
of MS angle 50mm x 50mm x 6mm, covered
with 3 mm aluminum sheet / F.R.P. Sheet on
both sides, the box assembly; shall be fixed to
the vertical pole. The box shall be pasted with
HIGH INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
381 RT-16-23 CODE. Letters or signages to be pasted on Nos 75010.00
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The refection
count shall not be less than 90% of its original
reflection after 7 years. The vertical poles shall
be provided with 20 mm dia 6 nos. hold fasts
embedded in 1:2:4 CC foundation of size 1500
mm x 1500mm as shown in drawing (3S-A1.1).
The assembly shall be treated with RustIcide
solution of approved company and applied with
Polyurethane primer and Paint to resist rusting
of material (the treatment shall be given as per
Manufactures
MANDATORYspecification
& CAUTIONARYand certificate
BOARD to

37
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Mandatory & Cautionary Board – Providing,
Fabricating, Erecting on site Mandatory &
Cautionary Boards (of type 1S-A-1), as per the
design incorporated in Street Furniture
catalogue volume–II published by M.C.G.M.,
Vertical poles shall be M.S. Square pipe of size
50mm x 50mm x 3.5mm thick. Signage plaque
(box) shall be of size 600mm dia. The box shall
be made of MS Square pipe of size 25mm x
25mm x3mm thick covered with 3 mm thick
aluminum sheet / F.R.P. Sheet on both sides,
The box assembly; shall be fixed to the vertical
pole. The box shall be pasted with HIGH
382 RT-16-24 INTENSITY GRADE retro reflective base Nos 8572.00
sheets on both sides conforming to I.R.C. 67
CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The refection
count shall not be less than 90% of its original
reflection after 7 years. The foundation shall
either be with base or either be with base plate
of M.S. of size 200 x 200 x 6mm thick, 16 mm
dia J Bolts or embedding the pole in foundation
with 12mm dia x 6 nos. hold fasts embedded
in 1:2:4 concrete as shown in drawing (IS-A.1).
The assembly
Mandatory & shall be painted
Cautionary with–matt
Board finish
Providing,
Fabricating, Erecting on site Mandatory &
Cautionary Boards (of type 1S-A-1). As per the
design incorporated in Street Furniture
catalogue volume–II published by M.C.G.M.,
Vertical poles shall be M.S. Square pipe of size
50mm x 50mm x 3.5mm thick. Signage plaque
(box) shall be of size 600mm dia. The box shall
be made of MS Square pipe of size 25mm x
25mm x3mm thick covered with 3 mm thick
aluminum sheet / F.R.P. Sheet on both sides,
The box assembly; shall be fixed to the vertical
pole. The box shall be pasted with HIGH
383 RT-16-25 INTENSITY GRADE retro reflective base Nos 8820.00
sheets on both sides conforming to I.R.C. 67
CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The refection
count shall not be less than 90% of its original
reflection after 7 years. The foundation shall
either be with base shall either be with base
plate of M.S. of size 200 x 200 x 6mm thick, 16
dia J Bolts or embedding the pole in foundation
with 12mm dia x 6 nos. hold fasts embedded
in 1:2:4 concrete as shown in drawing (IS-
A.1).Assembly
TRANGULAR BAORD shall be treated with resticide
AND RECTANGULAR
BAORD

38
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
TRANGULAR BAORD – Providing,
Fabricating, Erecting on site Mandatory Boards
(of type 1S-A-1.1). As per the design
incorporated in Street Furniture catalogue
volume–II published by M.C.G.M., Vertical
poles shall be M.S. Square pipe of size 50mm
x 50mm x 3.5mm thick Signage plaque (box)
shall be of size 900mm dia. The box shall be
made of MS Square pipe of size 50mm x
50mm x3mm thick covered with 3 mm thick
aluminum sheet / F.R.P. Sheet on both sides,
The box assembly; shall be fixed to the vertical
pole. The box shall be pasted with HIGH
384 RT-16-26 INTENSITY GRADE retro reflective base Nos 11758.00
sheets on both sides conforming to I.R.C. 67
CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The foundation shall
either be with base shall wither be with base
plate of M.S. of size 200 x 200 x 6mm thick, 16
mm dia J Bolts or embedding the pole in
foundation with 12mm dia x 6 nos. hold fasts
embedded in 1:2:4 concrete as shown in
drawing (IS-A.1). The
TRIANGULAR assembly–shall Providing,
BAORD be
Fabricating, Erecting on site Mandatory Boards
(of type 1S-A-1.1). As per the design
incorporated in Street Furniture catalogue
volume–II published by M.C.G.M., Vertical
poles shall be M.S. Square pipe of size 50mm
x 50mm x 3.5mm thick. Signage plaque (box)
shall be of size 900mm dia. The box shall be
made of MS Square pipe of size 50mm x
50mm x3mm thick covered with 3 mm thick
aluminum sheet / F.R.P. Sheet on both sides,
The box assembly; shall be fixed to the vertical
pole. The box shall be pasted with HIGH
385 RT-16-27 INTENSITY GRADE retro reflective base Nos 11999.00
sheets on both sides conforming to I.R.C. 67
CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The foundation shall
either be with base shall wither be with base
plate of M.S. of size 200 x 200 x 6mm thick, 16
dia J Bolts or embedding the pole in foundation
with 12mm dia x 6 nos. hold fasts embedded
in 1:2:4 concrete as shown in drawing (IS-A.1).
The assembly shall be treated with Rusti-cide

39
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

Mandatory Board hanging on pole – Providing,


Fabricating, Erecting on site Mandatory &
Cautionary Boards (of type 1S-A-3). As per the
design incorporated in Street Furniture
catalogue volume–II published by M.C.G.M.,
Signage plaque (box) shall be of size 600mm
dia. Mounted on existing electrical pole with GL
clamp. The box shall be made of 3mm thick
aluminum sheet / F.R.P. Sheet on both sides.
The circumferential edge shall be closed with 3
mm thick acrylic sheet. The box shall be
386 RT-16-29 Nos 5140.00
pasted with HIGH INTENSITY GRADE retro
reflective base sheets on both sides
conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflectivity of sheet shall have guarantee of
7 years. The reflection count shall not be less
than 90% of its original reflection after 7 years
shown in the drawing complete as per
specification and as directed by the Engineer.

TRIANGULAR AND RECTANGULAR BAORD


– Providing, Fabricating, Erecting on site
Mandatory Boards (of type 1S-A-1.2). As per
the design incorporated in Street Furniture
catalogue volume–II published by M.C.G.M.,
Vertical poles shall be M.S. Square pipe of size
50mm x 50mm x 3.5mm thick. Signage plaque
(box) shall be of size 900mm dia. The box shall
be made of M.S. Square pipe of size 25mm x
3mm thick covered with 3 mm thick aluminum
sheet / F.R.P. Sheet on both sides. In addition,
an informatory board of size 450mm x 450mm
below. These boxes shall be made of M.S.
Square pipes of size 25mm x 25mm x 3.5mm
387 RT-16-30 Nos 13400.00
thick and covered with 3mm thick aluminum /
F.R.P. sheet on both sides. The box shall be
pasted with HIGH INTENSITY GRADE retro
reflective base sheets on both sides
conforming to I.R.C. 67 CODE. Letters or
signages to be pasted on this box shall also be
of HIGH INTENSITY GRADE (up to 50% of
basic area) conforming to I.R.C. 67 CODE.
The reflectivity of sheet shall have guarantee of
7 years. The reflection count shall not be less
than 90% of its original reflection after 7 years.
The foundation shall either be with base plate
of M.S. of size 200 x 200 x 6mm thick, 16 dia J
Bolts or embedding the pole in foundation with
12mm dia x 6 nos. hold fasts embedded in

40
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
TRIANGULAR AND RECTANGULAR BAORD
– Providing, Fabricating, Erecting on site
Mandatory Boards (of type 1S-A-1.2). As per
the design incorporated in Street Furniture
catalogue volume–II published by M.C.G.M.,
Vertical poles shall be M.S. Square pipe of size
50mm x 50mm x 3.5mm thick. Signage plaque
(box) shall be of size 900mm dia. The box shall
be made of M.S. Square pipe of size 25mm x
3mm thick covered with 3 mm thick aluminum
sheet / F.R.P. Sheet on both sides. In addition,
an informatory board of size 450mm x 450mm
below shall be provided along with arrow box of
size 100mm x 450mm below. These boxes
388 RT-16-31 Nos 14255.00
shall be made of M.S. Square pipes of size
25mm x 25mm x 3.5mm thick and covered
with 3mm thick aluminum / F.R.P. sheet on
both sides. The box shall be pasted with HIGH
INTENSITY GRADE retro reflective base
sheets on both sides conforming to I.R.C. 67
CODE. Letters or signages to be pasted on
this box shall also be of HIGH INTENSITY
GRADE (up to 50% of basic area) conforming
to I.R.C. 67 CODE. The reflectivity of sheet
shall have guarantee of 7 years. The reflection
count shall not be less than 90% of its original
reflection after 7 years. The foundation shall
either be with base plate of M.S. of size 200 x
200 x 6mm fabricating,
Providing, thick, 16 dia Erecting
J Bolts oron
embedding
site Taxi
stand Boards as per the type, design approved
by M.M.R.T.A. as shown in drawing No.
E.E.Tr.Pb Type Drg/1/Taxi Stand Dt.23.4.2013
(Based on IRC-67-2012.)
Vertical Pole shall be of M.S.. Angle 50 mm x
50mm x 5mm thk, signage plaque (box) shall
be made of size 600 mm x 800 mm. The box
/frame shall be made of size 35 mm x 35 mm x
3 mm thick covered with Alluminium
Composite Panel (ACP) at size of 600 mm X
800 mm. The box assembly shall be fixed to
the vertical pole.
The box shall be pasted with 'HIGH
389 RT-16-32 Nos 8359.00
INTENSITY PRISMATIC GRADE (TYPE-IV)'
retro reflective base sheets confirming to
I.R.C.67 code. Letter & Taxi Logo signages to
be pasted on this box shall also be of HIGH
INTENSITY GRADE' (upto 50% of basic area)
confirming to I.R.C.67 code. The reflectivity of
sheet shall have guarantee of 7 years. The
reflection count shall not be less than 80% of
its original reflection after 7 years. The
foundation shall be of embedding the pole in
foundation with 200 mm x 200 mm x 6 mm thk.
Base plate embedded in 1:2:4 concrete as
shown in drawing. The assembly shall be
painted with two coats of antirust paint & two
coats
TREEof matt finish enamel paint, steel grey
GUARD

41
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

Circular tree guard : Providing and fabrication


and fixing M.S. Circular tree guard with circular
pipe of 10 gauge, 50mm Dia Circular vertical
post, 40mm Dia Horizontal support 18mm Dia.
intermediate support with M.S. cap- (type-I)
logo panel etc. including cutting welding,
riveting, oil painting with navy blue colour or
390 RT-16-33 any other approved colour shade as directed Per Unit 9713.00
and fixing in cement concrete foundation
including cement concrete paver block lining
including removal of surplus material/debries
and restoring damaged portion of footpath etc.
as directed.(Design details vide Drg.No.4F-AA,
4F-A1.2,A1.3 in the catalogue of street
Furniture (Vol.I) published by M.C.G.M.)

Hexagonal tree guard No.4F-tgu-B : Providing


and fabrication and fixing M.S. Hexagonal tree
guard with circular pipe of 10 gauge, 50mm Dia
Circular vertical post, 40mm Dia circular
horizontal support, 18mm Dia circular
intermediate support with M.S. cap-(type-I)
logo panel etc including cutting welding,
riveting, oil painting with navy blue colour any
391 RT-16-34 Sqm 10996.00
other approved colour shade as directed and
fixing in cement concrete foundation including
cement concrete paver block lining including
removal of surplus material/debries and
restoring damaged portion of footpath etc. as
directed. (Design details vide Drg.No.4F-B1 in
the catalogue of street Furniture (Vol.I)
published by M.C.G.M.)

Square tree guard : Providing and fabrication


and fixing M.S. Hexagonal tree guard with
circular pipe of 10 gauge, 50mm Dia Circular
vertical post, 40mm Dia circular horizontal
support, 18mm Dia circular intermediate
support with M.S. cap-(type-I) logo panel etc
including cutting welding, riveting, oil painting
392 RT-16-35 with navy blue colour any other approved Per. Unit 10149.00
colour shade as directed and fixing in cement
concrete foundation including cement concrete
paver block lining including removal of surplus
material/debries and restoring damaged
portion of footpath etc. as directed. (Design
details vide Drg.No.4F-C1 in the catalogue of
street Furniture (Vol.I) published by M.C.G.M.)

42
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.

St. Street Pole benches 6F-D-ROI,1,6F-DRO2


and 6F-D-Ro3 : Providing and fabrication and
fixing stainless steel railing of 10 gauge 304
grade material having minimum nickel contain
not less than 10% (laboratory testing certificate
shall be provided for used material) 50mm Dia
circular pipe back rest with 100mm Dia circular Per Meter
393 RT-16-36 seat, supporting of including cutting welding Per Back 8559.00
riveting, polishing as directed and fixing in Rest Pipe
cement concrete foundation including removal
of surplus material /debris and restoring
damaged portion of foothpath , etc. (design
details vide Drg.No.6F-D-RO1 and 6F-D in the
catalogue of street Furniture (Vol.I) published
by M.C.G.M)

ROAD MARKING

Providing and applying hot applied


thermoplastic road marking material with glass
beads extremely high skid resistance 2.5mm
thick with primer coat (tack coat) for binding
on cement concrete road/paver blocks surface.
All labour materials with special aggregates
etc, as specified in B.S. part-I & II 1989 and
carrying out the marking on any road on center
394 RT-16-37 line and other lane marking continuous for Sqm 681.00
intermittent 10cm or 15cm width and also
pedestrian crossings stripes as well as
spraying further quality of glass beads of type II
uniformly into a mono layer on to the hot paint
line in quick succession of the paint spraying
operation @ 250gms per sq.mt. area as
directed and as per B.S./M.O.S.T. specification
in white /yellow colour

Providing and applying hot applied


thermoplastic road marking material with glass
beads extremely high skid resistance 2.5mm
thick without primer coat ( tack coat) on
asphalt road surface. All labour materials with
special aggregates etc, as specified in B.S.
part-I & II 1989 and carrying out the marking on
any road on center line and other lane marking
395 RT-16-38 Sqm 622.00
continuous for intermittent 10cm or 15cm width
and also pedestrian crossings stripes as well
as spraying further quality of glass beads of
type II uniformly into a mono layer on to the hot
paint line in quick succession of the paint
spraying operation @ 250gms per sq.mt. area
as directed and as per B.S./M.O.S.T.
specification in White /Yellow colour.

43
Traffic Department Schedule
2014
Sr No. Code No. Item Description Unit Rate in Rs.
Supplying / Fixing of Retro reflective road studs
confirming to ASTM D-4280 designated ‘H’:,
Two way Reflective markers in any colour
396 RT-16-39 inclusive of fixing on any road surface with the Each 355.00
use of adhesive as per specifications etc.
complete, anywhere in Greater Mumbai as
directed by the Engineer.

Supplying / Fixing of Retro reflective road studs


confirming to ASTM D-4280 designated ‘H’:,
One way Reflective markers in any colour
397 RT-16-40 inclusive of fixing on any road surface with the Each 338.00
use of adhesive as per specifications etc.
complete, anywhere in Greater Mumbai as
directed by the Engineer.

Supplying / Fixing of Median Marker with the


fluorescent Yellow- retro reflective sheeting (
surface) confirming to ASTM D-4956 type IX
speciation, with Two way Reflective markers
inclined around 20 degree (to vertical) inclusive
398 RT-16-41 Each 687.00
fixing on Median of any surface with the use of
special bituminous installation adhesive /epoxy
resin and nailing as per specifications at the
spacing of 2 to 5 mt. etc. complete, anywhere
in Greater Mumbai as directed by the Engineer.

44