B. Oil/Condensate Characteristics
1. Foaming: Nil ___________ Moderate ______√______ Severe ___________
2. Paraffin Problem: No ___√_____ Yes _________ (if Yes, give cloud point) _________°F
3. Slug Flow: No ___√____ Yes ______ (if Yes, give details such as maximum liquid rate, slug volume, etc.,
or suggest surge factor.) _________________________________________________________________
_____________________________________________________________________________________
C. Gas _____2_____ MMSCFD Sp. Gr. _____0,554_____ (Air = 1.0)
D. Operating Temperature (°F) _____80_____ Max _____-20____ Min
E. Operating Pressure (psig) _____720____ Max ______75____ Min
F. H2S Content ___________ Mole% CO2 Content ___________ Mole% (or ppm)
G. Geographical Location _________Thrace District_________________________________________
III. Coatings
A. External: Mfgr. Std ________ Other ______
Specify if Other ____________________________________________________________________
B. Internal (Specify) _________________________________________________________________
CAZGIR INS. ISI SISTEMLERI TIC. VE SAN. A.S.
TWO PHASE NATURAL GAS SEPARATOR REV. NO:0.0
PROJECT # : CZPT3-H/T-2K-720 CALC. BY : ÖMER EKER DATE : 1/25/2013
DWG # : - APPROVED BY : DATE :
_________________________________________________________________________________
_________________________________________________________________________________
H. Other __________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
CAZGIR INS. ISI SISTEMLERI TIC. VE SAN. A.S.
TWO PHASE NATURAL GAS SEPARATOR REV. NO:0.0
PROJECT # : CZPT3-H/T-2K-720 CALC. BY : ÖMER EKER DATE : 1/25/2013
DWG # : - APPROVED BY : DATE :
For n=1, V=RT/P. When selecting as standard conditions P=1 atm, T=273 K (=492⁰R), with the gas
constant R=0,0821 L.atm/(g-mol.K), one obtains:
Assume pressure equals always 1 atm, the volume at other (absolute) temperatures would be:
60 ⁰F=520⁰R; 122⁰F=581.67⁰R
V60= 359(520/492)~ 379 ft3/lb-mol
V104= 359(563.67/492)~ 411.3 ft3/lb-mol
V122= 359(581.67/492)~ 424.43 ft3/lb-mol
V-4= 359(455.67/492)~ 332.5 ft3/lb-mol
Actual volume flow rate of gas at operating conditions=
(2000000 SCF/DAY x 20.3 lb/mol )/(332.5 SCF/mol x86400 s/day x 2.35lb/ft³)
= 0.65 f³/s
Liquid capacity is satisfactory for design based on 24-in. ID x 6ft Vertical separator size.
*The 379.482 scf/lb-mole @ 60F is a constant for converting Lb-moles of any gas to SCF of gas. This constant is at
60 F. It is also similar to the constant of 22.414 l of gas/ g-mole of gas @ 25 c. The bottom line is that 1 g-mole of any
gas always occupies 22 liters of space at 25 C in metric units and in english units that constant is
379.482 scf/lb-mole @ 60 F
Flowing gas density is 3.40lb/ft^3 for 20.3 mol w.t. Gas
Molecular weight
Methane 16.043
Natural Gas= 19.5-20.3
CAZGIR INS. ISI SISTEMLERI TIC. VE SAN. A.S.
TWO PHASE NATURAL GAS SEPARATOR REV. NO:0.0
PROJECT # : CZPT3-H/T-2K-720 CALC. BY : ÖMER EKER DATE : 1/25/2013
DWG # : - APPROVED BY : DATE :
= 79.53 mm²
33. Fluid and State: Natural Gas / Gas 28. Cap: Screwed [ ] Bolted [*]
34. Required Capacity per Valve and Units:3361902 kg/h 29. Lifting Lever: Plain [ ] Packed [ ] None [*]
35. Molecular Weight or Specific Gravity: 16 30. Test Gag: Yes [ ] No [*]
36. Viscosity at Flowing Temp. and units: - 31. Bug Screen: Yes [ ] No [*]
37. Operating Pressure and Units: 75psig 32. Other [ ] Specify:
38. Set Pressure and Units: 75 psig
39. Blowdown: Standard [*] Other [ ]
40. Latent Heat of Vaporization and Units: 510 kJ/kg
SIZING AND SELECTION
41. Operation Temperature and units: 40⁰C
42. Relieving Tempereture and units: 30⁰C 49. Calculated Orifice Area (in square inches):0,124
43. Built-up backpressure and units: 50. Selected Effective Orifice Area (in square inches):0,196
44. Superimposed backpressure and units: 0 51. Orifice Designation (letter): E
45. Cold diferential test pressure and units: 52. Manufacturer:
46. Allowable Overpressure in Percent of Units: 10 53 Model Number:
47. Compressiblity Factor, Z: 0,85 54. Vendor Calculations Required: Yes [*] No [ ]
48. Ratio of Specific Heats: 1,31