Вы находитесь на странице: 1из 1

FLOWSIC600 - Flow calculations Process & Custody

Project: DD FOR PRODUCTION SEPARATOR SKID PACKAGE


TAG Number: 20X-FIT-XX1
Service Produced Gas Reference conditions standardization vs actual
Process Parameter T ref: 15.56 °C
ref. Number P ref: 1.013250 bar a

inch inch or m
Line size: 12 12.7519 inch
Wall thickness: XS/80S 0.5000 inch
Path angle: 60 °
Flow conditioner: PTB

Enter check points: min. norm. max. Unit


Massflow 615.00 36080.00 43296.00 kg/h
T avg: 15.00 35.00 55.00 °C
Pabs avg: 8.01 8.01 8.01 bar Absolute pressure
Pgag avg: 7.00 7.00 7.00 bar Gage

Calculation results
Mol. weight: 24.82 kg/kmol Connection diam.: 0.2985 m
Connection area: 0.0700 m²

Check point min norm max Unit


SOS calcu.: 339.700 351.461 362.527 m/s
Massflow 615.000 36080.000 43296.000 kg/h Mass flow
Q sc at 584.7 34305.3 41166.4 nm³/h Standard flow
Q ac at 71.7 4530.9 5820.4 m³/h Actual flow
Pipe Velocity 0.285 17.985 23.103 m/s Gas velocity
Reynolds no 74656 4111660 4654700
Dp meter 0.00060 1.56582 2.39630
mbar
Dp meter + FC 0.009 33.762 52.027

Note: Velocity calculations are within FLOWSIC600 capabilities which fits the entire application range