Вы находитесь на странице: 1из 5

ON-OFF POTENTIAL SURVEY DATA SHHET

DATE: 22.03.2016

NAME OF SURVEYOR: Rajesh SHEET: ______ OF _______

PIPELINE DESCRIPTION: TR UNIT / BONDING DETAILS

4" HEADER PIPELINES FROM GIP TO SB-135 AND 3"


PIPELINE ID: TR OUTPUT: 6.85 V 6.08 A
BRANCH PIPELINES

PIPELINE DIAMETER: 4" & 3" PIPELINES BONDING LOCATION: 0+094 RDS-6 6" WAG 32

CREDO CHILDREN ID: ASAB_14-16-CP-SYSTEM6803-06 BOND CURRENT: 0.042 A

ISOLATION FLANGE /
PIPELINE FOREIGN PIPELINE CROSSING / PARALLALISM
ISOLATION JOINT UN- COUPON
KILOMETER PROTECTED SIDE
Sl. # TEST POST ID REMARKS / ANOMALY
CHAINAGE
ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) FOREIGN PIPELINE ID ON (-mV) OFF (-mV)

1 NEW FBB 2+890 1378 1026 6" Zone B 1424 971

2 36" MOL ASAB TO BAB 1312 1312

3 NEW FBB 2+910 1329 987 6" Zone B 1424 971

4 26" TR RDS-4 1404 1404

5 12" PWI 1404 1404

6 10" GAS LIFT 1404 1404

7 NEW FBB 2+920 1537 1140 6" Zone B 1537 1140

8 20' TR RDS-5 1774 1774

9 8" GAS LIFT 1774 1774

10 NEW FBB 2+930 1594 1177 6" Zone B 1588 1162

11 30" RDS-3 1427 1427

12 PTP 3+000 1564 1128

13 NEW FBB 1597 1168 30" RDS-3 1427 1427

14 NEW FBB 1508 1124 20" TL RDS-5 1774 1774

15 8" GAS LIFT RDS-5 1774 1774


ON-OFF POTENTIAL SURVEY DATA SHHET
DATE: 22.03.2016

NAME OF SURVEYOR: Rajesh SHEET: ______ OF _______

PIPELINE DESCRIPTION: TR UNIT / BONDING DETAILS

4" HEADER PIPELINES FROM GIP TO SB-135 AND 3"


PIPELINE ID: TR OUTPUT: 6.85 V 6.08 A
BRANCH PIPELINES

PIPELINE DIAMETER: 4" & 3" PIPELINES BONDING LOCATION: 0+094 RDS-6 6" WAG 32

CREDO CHILDREN ID: ASAB_14-16-CP-SYSTEM6803-06 BOND CURRENT: 0.042 A

ISOLATION FLANGE /
PIPELINE FOREIGN PIPELINE CROSSING / PARALLALISM
ISOLATION JOINT UN- COUPON
KILOMETER PROTECTED SIDE
Sl. # TEST POST ID REMARKS / ANOMALY
CHAINAGE
ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) FOREIGN PIPELINE ID ON (-mV) OFF (-mV)

16 FTP 0+478 1460 1080 18"OLD RDS-3 580 580

17 FTP 0+502 1555 1179 RDS-5 700 700


SB-153 Tie-in With 4"
18 IJTP 0+683.07 1501 1162 926 926 Headers. 4" PL IJTP inside
Well- Sb 153
19 PTP 4+000 ___ ___ TP Burried.
SB-019 Tie-in With 4"
20 IJTP 0+442.06 1312 1027 900 900 Headers. 4" PL IJTP inside
Well- Sb 019
21 NEW FBB ___ 1547 1176 6" WAG 32 1352 1205

22 8' WAG 39 1348 1202


4" PL IJTP inside Well- Sb-
IJTP ___ 1486 1142 666 666 137. IJTP inside Well- Sb-
137
PTP 5+000 1504 1201

PTP 6+000 1497 1255

FTP 6+700 1437 1232 FL XING 1350 1350

23 SB-281 1349 1349

24 FTP 0+115 1329 1118 6" Zone B 1340 1124


SB-008 Tie-in With 4"
25 IJTP 0+380 1157 972 912 912 Headers. 4" PL IJTP inside
Well- Sb- 008
26 PTP 8+000 1334 1181
ON-OFF POTENTIAL SURVEY DATA SHHET
DATE: 22.03.2016

NAME OF SURVEYOR: Rajesh SHEET: ______ OF _______

PIPELINE DESCRIPTION: TR UNIT / BONDING DETAILS

4" HEADER PIPELINES FROM GIP TO SB-135 AND 3"


PIPELINE ID: TR OUTPUT: 6.85 V 6.08 A
BRANCH PIPELINES

PIPELINE DIAMETER: 4" & 3" PIPELINES BONDING LOCATION: 0+094 RDS-6 6" WAG 32

CREDO CHILDREN ID: ASAB_14-16-CP-SYSTEM6803-06 BOND CURRENT: 0.042 A

ISOLATION FLANGE /
PIPELINE FOREIGN PIPELINE CROSSING / PARALLALISM
ISOLATION JOINT UN- COUPON
KILOMETER PROTECTED SIDE
Sl. # TEST POST ID REMARKS / ANOMALY
CHAINAGE
ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) FOREIGN PIPELINE ID ON (-mV) OFF (-mV)
SB-135 Tie-in With 4"
27 IJTP 8+269.73 1226 967 866 866 Headers. 4" PL IJTP inside
Well- Sb- 135
28

29 FTP 0+115 1329 1118 6" Zone B 1340 1124


SB-008 Tie-in With 4"
30 IJTP 0+380 1157 972 912 912 Headers. 4" PL IJTP inside
Well- Sb- 008
31 PTP 8+000 1334 1181
SB-135 Tie-in With 4"
32 IJTP 8+269.73 1226 967 866 866 Headers. 4" PL IJTP inside
Well- Sb- 135
33 12" PWI 1404 1404

34 10" GAS LIFT 1404 1404

35 NEW FBB 2+920 1537 1140 6" Zone B 1537 1140

36 20' TR RDS-5 1774 1774

37 8" GAS LIFT 1774 1774

38 NEW FBB 2+930 1594 1177 6" Zone B 1588 1162

39 30" RDS-3 1427 1427

40 PTP 3+000 1564 1128

41 NEW FBB 1597 1168 30" RDS-3 1427 1427


ON-OFF POTENTIAL SURVEY DATA SHHET
DATE: 22.03.2016

NAME OF SURVEYOR: Rajesh SHEET: ______ OF _______

PIPELINE DESCRIPTION: TR UNIT / BONDING DETAILS

4" HEADER PIPELINES FROM GIP TO SB-135 AND 3"


PIPELINE ID: TR OUTPUT: 6.85 V 6.08 A
BRANCH PIPELINES

PIPELINE DIAMETER: 4" & 3" PIPELINES BONDING LOCATION: 0+094 RDS-6 6" WAG 32

CREDO CHILDREN ID: ASAB_14-16-CP-SYSTEM6803-06 BOND CURRENT: 0.042 A

ISOLATION FLANGE /
PIPELINE FOREIGN PIPELINE CROSSING / PARALLALISM
ISOLATION JOINT UN- COUPON
KILOMETER PROTECTED SIDE
Sl. # TEST POST ID REMARKS / ANOMALY
CHAINAGE
ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) FOREIGN PIPELINE ID ON (-mV) OFF (-mV)

42 NEW FBB 1508 1124 20" TL RDS-5 1774 1774

43 8" GAS LIFT RDS-5 1774 1774

44 FTP 0+478 1460 1080 18"OLD RDS-3 580 580

45 FTP 0+502 1555 1179 RDS-5 700 700


SB-153 Tie-in With 4"
46 IJTP 0+683.07 1501 1162 926 926 Headers. 4" PL IJTP inside
Well- Sb 153
47 PTP 4+000 ___ ___ TP Burried.
SB-019 Tie-in With 4"
48 IJTP 0+442.06 1312 1027 900 900 Headers. 4" PL IJTP inside
Well- Sb 019
49 NEW FBB ___ 1547 1176 6" WAG 32 1352 1205

50 8' WAG 39 1348 1202


4" PL IJTP inside Well- Sb-
51 IJTP ___ 1486 1142 666 666 137. IJTP inside Well- Sb-
137
52 PTP 5+000 1504 1201

53 PTP 6+000 1497 1255

54 FTP 6+700 1437 1232 FL XING 1350 1350

55 SB-281 1349 1349

56 PTP 7+000 1366 1167


ON-OFF POTENTIAL SURVEY DATA SHHET
DATE: 22.03.2016

NAME OF SURVEYOR: Rajesh SHEET: ______ OF _______

PIPELINE DESCRIPTION: TR UNIT / BONDING DETAILS

4" HEADER PIPELINES FROM GIP TO SB-135 AND 3"


PIPELINE ID: TR OUTPUT: 6.85 V 6.08 A
BRANCH PIPELINES

PIPELINE DIAMETER: 4" & 3" PIPELINES BONDING LOCATION: 0+094 RDS-6 6" WAG 32

CREDO CHILDREN ID: ASAB_14-16-CP-SYSTEM6803-06 BOND CURRENT: 0.042 A

ISOLATION FLANGE /
PIPELINE FOREIGN PIPELINE CROSSING / PARALLALISM
ISOLATION JOINT UN- COUPON
KILOMETER PROTECTED SIDE
Sl. # TEST POST ID REMARKS / ANOMALY
CHAINAGE
ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) ON (-mV) OFF (-mV) FOREIGN PIPELINE ID ON (-mV) OFF (-mV)

57 FTP 0+115 1329 1118 6" Zone B 1340 1124


SB-008 Tie-in With 4"
58 IJTP 0+380 1157 972 912 912 Headers. 4" PL IJTP inside
Well- Sb- 008
59 PTP 8+000 1334 1181
SB-135 Tie-in With 4"
60 IJTP 8+269.73 1226 967 866 866 Headers. 4" PL IJTP inside
Well- Sb- 135

Вам также может понравиться