Вы находитесь на странице: 1из 2

SPECIFICATION CLAUSES FOR STEEL TO ENSURE COMPLIANCE

WITH RELEVANT AUSTRALIAN STANDARDS / REGULATIONS


ITEMS IN RED OR GREEN – SELECT AS APPROPRIATE OR SEEK ASSISTANCE FROM MANUFACTURER.

Prepainted Steel –Roofing/Cladding Standard Residential and Low-Rise Steel Framing Part 1 or
Prepainted Steel for Roofing/Cladding (COLORBOND® steel Part 2 and relevant manufacturer Technical Bulletins.
or equivalent) conforming to AS2728:2013 with a metallic- Product to meet tolerance specification of AS/NZS1365:1996
coated steel substrate conforming to AS1397:2011-
G300/G500/G550 - AM100/AM150. Cold-Formed Structural (Purlins)
Product is to be legibly and durably marked on reverse Cold-Formed Purlins Structural (GALVASPAN® steel or
surface with the manufacturer name and/or trademark, unique equivalent) meeting the requirements of AS1397:2011-
traceable identifier and date of manufacture. G450/G500/G550 - Z350/Z450.
Installation of product shall be in compliance with Product is to be legibly and durably marked on one surface in
AS1562.1:1992 and HB-39:2015, National Construction Code accordance with AS1397:2011 indicating steel grade, base
(NCC) and relevant manufacturer Technical Bulletins. metal thickness, coating class and reference to AS1397 to
Product to meet tolerance specification of AS/NZS1365:1996 indicate compliance to that standard.
Installation of product shall be in compliance with
Metal Coated Steel – Roofing/Cladding (Al/Zn/Mg) AS4600:2005 and relevant manufacturer Technical Bulletins.
Metal Coated Steel for Roofing/Cladding (ZINCALUME® steel Product to meet tolerance specification of AS/NZS1365:1996
or equivalent) meeting the requirements of AS1397:2011-
G300/G500/G550 - AM125/AM150. Structural Steel Decking
Product is to be legibly and durably marked on one surface in Structural Steel Decking (DECKFORM® steel or equivalent)
accordance with AS1397:2011 indicating steel grade, base meeting the requirements of AS1397:2011-G500/G550 -
metal thickness, coating class and reference to AS1397 to Z350/Z450.
indicate compliance to that standard. Product is to be legibly and durably marked on one surface in
Installation of product shall be in compliance with accordance with AS1397:2011 indicating steel grade, base
AS1562.1:1992 and HB-39:2015, National Construction Code metal thickness, coating class and reference to AS1397 to
(NCC) and relevant manufacturer Technical Bulletins. indicate compliance to that standard.
Product to meet tolerance specification of AS/NZS1365:1996 Application of product shall be in compliance with
AS3600:2009 and relevant manufacturer Technical Bulletins.
Metal Coated Steel – Roofing/Cladding (Galvanised) Product to meet tolerance specification of AS/NZS1365:1996
Galvanised Coated Steel – Roofing/Cladding (ZINC HI-TEN®
steel or equivalent) meeting the requirements of Hot-Rolled Plate steel
AS1397:2011-G300/G500/G550 - Z450/Z600. Hot-Rolled Plate (XLERPLATE® steel or equivalent)
manufactured to meet the requirements of AS/NZS3678:2011
Product is to be legibly and durably marked on one surface in
by an independent 3rd party accredited certified manufacturer.
accordance with AS1397:2011 indicating steel grade, base
metal thickness, coating class and reference to AS1397 to Steel to be legibly marked with steel grade, applicable
indicate compliance to that standard. Australian Standard, heat number, traceable identification
number, name of manufacturer and independent 3rd party
Installation of product shall be in compliance with
accredited certified certification number.
AS1562.1:1992 and HB-39:2015, National Construction Code
(NCC) and relevant manufacturer Technical Bulletins. Test certificates for materials supplied to be made available
upon request. Testing and certificates to be completed by
Product to meet tolerance specification of AS/NZS1365:1996
NATA (or similar) approved testing facility in accordance with
the requirements of ISO /IEC 17025 & AS1391:2007.
Metal Coated Steel – Steel Building Frame (Al/Zn/Mg)
Application of steel product shall be in compliance with AS
Metal Coated Steel for Steel Building Frame (TRUECORE®
1554.1, AS4100:1998 and relevant manufacturer publications.
steel or equivalent) meeting the requirements of
AS1397:2011-G450/G500/G550 - AM150. Product to meet tolerance specification of AS/NZS1365:1996
Product is to be legibly and durably marked on one surface in
accordance with AS1397:2011 indicating steel grade, base
metal thickness, coating class and reference to AS1397 to
indicate compliance to that standard.
Installation of product shall be in compliance with
AS4600:2005, National Construction Code (NCC), NASH

COLORBOND®, ZINCALUME®, ZINC HI-TEN®, TRUECORE®, GALVASPAN®, DECKFORM®, XLERPLATE®, TRU-SPEC®, BlueScope are registered trade marks of BlueScope Steel Limited. 1
BlueScope and the BlueScope brand mark are registered trade marks of BlueScope Steel Limited. © 2016 BlueScope Steel Limited ABN 16 000 011 058. All rights reserved
SPECIFICATION CLAUSES FOR STEEL TO ENSURE COMPLIANCE
WITH RELEVANT AUSTRALIAN STANDARDS / REGULATIONS
ITEMS IN RED OR GREEN – SELECT AS APPROPRIATE OR SEEK ASSISTANCE FROM MANUFACTURER.

Hot-Rolled Strip and Plate


Hot-Rolled Strip and Plate (TRU-SPEC® steel or equivalent) References
manufactured to meet the requirements of AS/NZS
1594:2002. Steel to be legibly marked with steel grade, AS/NZS1365:1996 Tolerances for flat-rolled steel
dimensions, traceable identification number and name of products
manufacturer.
AS1391:2007 Metallic materials – Tensile testing
Test certificates for materials supplied to be made available at ambient temperature
upon request. Testing and certificates to be completed by
NATA (or similar) approved testing facility in accordance with AS1397:2011 Continuous hot-dip metallic coated
the requirements of ISO /IEC 17025. steel sheet and strip – Coatings of
zinc and zinc alloyed with
Application of steel product shall be in compliance with AS aluminium and magnesium
1554.1, AS4100:1998 and relevant manufacturer publications
where applicable. AS 1554.1 Welding of Steel Structures
Product to meet tolerance specification of AS/NZS1365:1996 AS1562.1:1992 Design and installation of sheet
roof and wall cladding Part 1:
General – Installation Metal
Where applicable, installation of product shall be in AS/NZS2728:2013 Prefinished/prepainted sheet metal
compliance with AS1562.1:1992 and HB-39:2015, National products for interior/exterior
Construction Code (NCC) and relevant manufacturer building applications –
Technical Bulletins. Performance requirements
Product to meet tolerance specification of AS/NZS1365:1996
AS3600:2009 Concrete structures
General – Environmental
AS/NZS3678:2011 Structural steel – Hot-rolled plates,
For projects, requiring Green Star Certification the floorplates and slabs
manufacturer of the steel products must be able to
demonstrate ISO9001:2008 & ISO14001:2004 accreditation AS4100 Steel structures
and current membership to the World Steel Climate Action AS/NZS4600:2005 Cold-formed steel structures
Program.
HB-39:2015 Installation code for metal roof and
wall cladding
ISO9001:2008 Quality Management Systems -
Requirements
ISO14001:2004 Environmental management
systems
NCC National Construction Code Vol. 1
& Vol. 2
ISO/ IEC 17025 General requirements for the
competence of testing and
calibration laboratories

COLORBOND®, ZINCALUME®, ZINC HI-TEN®, TRUECORE®, GALVASPAN®, DECKFORM®, XLERPLATE®, TRU-SPEC®, BlueScope and the BlueScope brand mark are registered trade
marks of BlueScope Steel Limited. © 2016 BlueScope Steel Limited ABN 16 000 011 058. All rights reserved
2

Вам также может понравиться