Академический Документы
Профессиональный Документы
Культура Документы
150 1200 150 GROVE VENT WITH MESH 200 1100 200 GROVE VENT WITH MESH
GL @20M INTERVAL NOTES:-
GL @20M INTERVAL
150
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS
200
UNLESS OTHERWISE SPECIFIED.
ROAD SHOULDER 2. DO NOT SCALE THE DRAWING FOLLOW FIGURED DIMENSIONS ONLY.
ROAD SHOULDER 3. ALL DESIGN MIX CONCRETE SHALL CONFORM TO CL: 6.4 & CL: 18.5 OF
IRC: 112-2011.
4. SEISMIC ZONE - III
100
100
5. CLEAR COVER TO REINFORCEMENT :
SELECTIVE EARTH FILLING SELECTIVE EARTH FILLING RCC DRAIN : 75mm FOR ALL SOIL FACES
50mm FOR ALL OTHER THAN SOIL FACES
6. 100 Ø WEEP HOLES IN SLOPE 1:20 @ 2000 C/C ALONG THE LEGTH.
7. INCASE OF FILLED UP SOIL / LOOSE POCKETS ENCOUNTERED AT
FOUNDING LEVEL. THEN THE SAME SHALL BE REPLACED BY
PROVIDING WELL GRADED NON PLASTIC COARSE MATERIAL
GSB GSB COMPACTED TO 98% MDD TO ACHIEVE THE DESIGNED BASE
Ht UPTO 0.95m
0.9m IN TO NATURAL GROUND AS PER CL. 23.3 IRC: SP-13-2004).
WEEP HOLE @100mm DIA WEEP HOLE @100mm DIA
2.0m C/C ALONG THE 2.0m C/C ALONG THE
LENGTH LENGTH
RCC M-30 RCC M-30
SPECIFICATIONS:-
75
150
150
FOUNDATION
FOUNDATION
100
100
BLANKET LAYER PCC M15
BLANKET LAYER PCC M15
COVERED RECTANGULAR DRAIN
COVERED RECTANGULAR DRAIN
(SCALE 1 : 100)
(SCALE 1 : 100)
MS FLAT
MS FLAT 20x3
450x20x3
MS STEEL
100
10mm Ø @
50C/C
300
MS GALVANIZED GRATING
(SCALE 1: 5)
Vax
200
200
ROAD SHOULDER ROAD SHOULDER
1100
8Ø @ 200 c/c 10Ø @ 150 c/c 10Ø @ 125 c/c
Ht UPTO 0.95m
WEEP HOLES WEEP HOLES
@100mm DIA @ 100mm DIA
10Ø @ 150 c/c 10Ø @ 125 c/c
8Ø @ 125 c/c
75
200
100
100
FOUNDATION FOUNDATION
BLANKET LAYER M15 GRADE 10Ø @150 c/c BLANKET LAYER M15 GRADE 12Ø @ 125 c/c
NOTES:-
SPECIFICATIONS:-
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS
UNLESS OTHERWISE SPECIFIED. · GRADE OF STEEL SHALL BE OF CRS - Fe500D OR ITS EQUIVALENT.
2. DO NOT SCALE THE DRAWING FOLLOW FIGURED DIMENSIONS ONLY. · RCC DRAIN IN M30 (DESIGN MIX), USING 20mm ISS HBG GRADED
3. ALL DESIGN MIX CONCRETE SHALL CONFORM TO CL: 6.4 & CL: 18.5 OF METAL (FOR DETAILS REFER SEPERATE DRAWING).
IRC: 112-2011. · PCC BELOW DRAIN IN PCC M15 (NOMINAL MIX) 100mm THICK, USING
4. SEISMIC ZONE - III 20mm ISS HBG GRADED METAL.
5. CLEAR COVER TO REINFORCEMENT :
RCC DRAIN : 75mm FOR ALL SOIL FACES
50mm FOR ALL OTHER THAN SOIL FACES
6. 100 Ø WEEP HOLES IN SLOPE 1:20 @ 2000 C/C ALONG THE LENGTH.
7. INCASE OF FILLED UP SOIL / LOOSE POCKETS ENCOUNTERED AT
FOUNDING LEVEL. THEN THE SAME SHALL BE REPLACED BY
PROVIDING WELL GRADED NON PLASTIC COARSE MATERIAL
COMPACTED TO 98% MDD TO ACHIEVE THE DESIGNED BASE
PRESSURE. (THE BOTTOM OF REPLACED LAYER SHALL BE MINIMUM
0.9m IN TO NATURAL GROUND AS PER CL. 23.3 IRC: SP-13-2004).
Vax
TITLE:
BSCPL Infrastructure Limited. GPS Consulting Engineers
R0 26-06-18 INITIAL SUBMISSION Hyderabad,Telangana, India Foundation & Structural Engineers Hyderabad, Telangana, India TYPICAL DETAILS OF RCC CROSS DRAIN
No. 18, Gangai Amman Koil 4th Street
Vadapalani, Chennai - 600 026. SHEET
REV. DATE DESCRIPTION OF REVISIONS SEAL & SEAL & SEAL &
SIGNATURE SIGNATURE SIGNATURE 02 OF 03
DRG.NO.: VCPL / NH216 / STR / DRAIN / WD - 01
8Ø @ 200 c/c
8Ø @ 200 c/c 8Ø @ 150 c/c
10Ø @150 c/c 150 150
200 200
150
200
ROAD SHOULDER
ROAD SHOULDER
1200
Ht UPTO 0.95m
8Ø @ 200 c/c
WEEP HOLES
WEEP HOLES @ 100mm DIA
@ 100mm DIA 8Ø @ 150 c/c
10Ø @ 150 c/c
8Ø @ 200 c/c
8Ø @ 200 c/c
8Ø @ 200 c/c
75
150
75
200
100
100
8Ø @ 150 c/c
8Ø @ 200 c/c
FOUNDATION
FOUNDATION
BLANKET LAYER M15 GRADE 10Ø @ 150 c/c
BLANKET LAYER M15 GRADE
COVERED RCC DRAIN @ RESTRICTED COVERED RCC DRAIN @ RESTRICTED
ROW FROM 0.95m TO 1.5m HEIGHT ROW UPTO 0.95m HEIGHT
(SCALE 1 : 100) (SCALE 1 : 100)
NOTES:-
SPECIFICATIONS:-
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS
UNLESS OTHERWISE SPECIFIED. · GRADE OF STEEL SHALL BE OF CRS - Fe500D OR ITS EQUIVALENT.
2. DO NOT SCALE THE DRAWING FOLLOW FIGURED DIMENSIONS ONLY. · RCC DRAIN IN M30 (DESIGN MIX), USING 20mm ISS HBG GRADED
3. ALL DESIGN MIX CONCRETE SHALL CONFORM TO CL: 6.4 & CL: 18.5 OF METAL (FOR DETAILS REFER SEPERATE DRAWING).
IRC: 112-2011. · PCC BELOW DRAIN IN PCC M15 (NOMINAL MIX) 100mm THICK, USING
4. SEISMIC ZONE - III 20mm ISS HBG GRADED METAL.
5. CLEAR COVER TO REINFORCEMENT :
RCC DRAIN : 75mm FOR ALL SOIL FACES
50mm FOR ALL OTHER THAN SOIL FACES
6. 100 Ø WEEP HOLES IN SLOPE 1:20 @ 2000 C/C ALONG THE LENGTH.
7. INCASE OF FILLED UP SOIL / LOOSE POCKETS ENCOUNTERED AT
FOUNDING LEVEL. THEN THE SAME SHALL BE REPLACED BY
PROVIDING WELL GRADED NON PLASTIC COARSE MATERIAL
COMPACTED TO 98% MDD TO ACHIEVE THE DESIGNED BASE
PRESSURE. (THE BOTTOM OF REPLACED LAYER SHALL BE MINIMUM
0.9m IN TO NATURAL GROUND AS PER CL. 23.3 IRC: SP-13-2004).
Vax
TITLE:
BSCPL Infrastructure Limited. GPS Consulting Engineers
R0 26-06-18 INITIAL SUBMISSION Hyderabad,Telangana, India Foundation & Structural Engineers Hyderabad, Telangana, India TYPICAL DETAILS OF RCC CROSS DRAIN
No. 18, Gangai Amman Koil 4th Street
Vadapalani, Chennai - 600 026. SHEET
REV. DATE DESCRIPTION OF REVISIONS SEAL & SEAL & SEAL &
SIGNATURE SIGNATURE SIGNATURE 03 OF 03
DRG.NO.: VCPL / NH216 / STR / DRAIN / WD - 01