ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT

SAVE 10 TO 20% IN ELECTRICITY BILLS

Department Of Electrical Engineering


Faculty Of Engineering and Technology
Jamia Millia Islamia,New Delhi-110025

CONTACT: Dr. V. K. Sharma


Telefax: 26982651

Power Quality and Energy Audit Facility


at Electrical Engineering Department of
Jamia Millia Islamia,DELHI

Background:

“Energy Saved is Energy Generated”

India is facing grave crisis due to acute Shortage of Electrical Energy and ever growing demand.
With 80,000MW of installed capacity country needs an additional 80,000MW during the next
five years. Bulk of the Electricity is consumed by Industrial sector followed by Agriculture,
domestic and commercial applications. More than 70% of the electricity is consumed by electric
motors mainly in industry, agriculture and domestic appliances. Even a 5% saving in electricity
will prevent the need to install power plants of a few thousand MW. Energy conservation has
now become a necessity with Government of India formulating mandatory Energy Audit and
Energy conservation regulations.

Considerable energy saving is possible through proper choice of equipment, and their effective
use. Data of energy consumption pattern through Energy Audit for any given application
essential to evolve conservation measures. Since diagnosis proceeds treatment ant not an end in
itself one should find technical solution for the problem of inefficient energy use. In view of the
above, a State of the Art “Electrical Energy Audit and Energy Conservation” facility has been
established.

Facilities Established

Following facilities/laboratory have been established


1- Energy Instrumentation facility
2- Computerized test facility for Energy Converters and drives
3- Computation and CAD facility for Energy System
4- Electrical Machine Design Center.

Electrical Energy Audit:


ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS

Electrical Energy Audit for different establishments can be carried out by the sophisticated
Instrumention and Data acquisition facility comprising the following instruments and accessories

1. PLC BASED DATA ACQUISTION SYSTEM


FOR TESTING MOTOR & DRIVES

PLC-5/30 (Allen Bradley-USA)


Power Monitor (Allen Bradley-USA)
Variable Freq. Drive (Allen Bradley-USA)
Digital DC Drive (Kirloskar- India)
Torque Transducer (Vibrometer- Switzerland)

2. INSTRUMENTION FACILITY

a) Power Analyzer

3Phase(PM3300) Voltech (UK)


3Phase(PM300) Voltech (UK)
Single Phase(Pm100) Voltech (UK)

B) Oscilloscopes

4Channel Oscilloscope Hewlett Packard(USA)


(54602b)
Tektronix Real Time Tektronix (USA)
(TSH720)
Scope Meter Fluke (Holland)

C) Clamp On Current/Voltage/Power Meter

Digital ClampMeter Kyorisu (Japan)


Digital Clamp-On Tester Yokogawa (Japan)
AC/DC Clamp Meter Fluke (Holland)
HP974A Multimeter Hewlett Packard (USA)
HP34401A Multimeter Hewlett Packard (USA)

D) Non-Electrical Quantity Meters

Digital Tachometer Yokogawa (Japan)


Digital Thermometer Yokogawa (Japan)
Illuminance Meter Yokogawa (Japan)
Sound Level Meter Yokogawa (Japan)
Portable Lux Meter Yokogawa (Japan)
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS

E) Testers

Leakage Current Tester Yokogawa (Japan)


Earth Tester Yokogawa (Japan)
Digital InsulationTester Yokogawa (Japan)
Electronic Moter Checker Electronik (India)

F) ENERGY METER:

Electronic Trivector Meter L&T India Ltd.


Thus electrical and non-electrical quantities can be monitored under actual operating conditions.
After collecting the relevant data practical and reliable technical solutions can be evolved in each
case to effect energy-saving.

3) COMPUTER AIDED DESIGN SOFTWARE:

1) ETAP
2) Integrated Motor Design Software
3) Microsim Design lab
4) Matlab/Simulink/
5) Powersystem
6) Robust Control

Who can use the facility?

Any Industry or organization using considerable electricity and paying significant energy bills
should energy audit through the above facility. Typical users may be:

Industry

• Textile Mills
• Cement Plants
• Steel and Metals
• Petrochemicals
• Machine Tools
• Mining
• Irrigation and Agriculture (Pump sets)
• Power Plants
• Government Buildings/Departments
• University Campuses/R&D Institutions
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS

• Commercial Establishments e.g: Hotels, shopping complexes


• Computer Centers/ IT users
• Domestic Sector

Types of Energy Audit:

Energy Audit is a comprehensive study having following


typical applications of electrical energy
= Motors driving pumps, blowers, compressors and fans
= Substation/Lighting
= Illumination/Lighting
= Electric Furnaces/Heating
= Electric Appliances

Since motors are the workhorses in industry they are the major energy guzzlers. We should
ensure their more efficient operation which may lead to energy labeling. Considerable energy
saving is possible by improved power transmission in Drive and use of energy efficient
equipment,s. Energy audit often includes power quality to assess the nature of supply voltages,
unbalance, frequency and waveform, based on which suggestions may emerge to improve
power quality. Sophisticated instrumentation procured by us. Facilitates detailed studies to
arrive at appropriate solutions.

Total Solution Ensured:

Apart from the sophisticated and State of Art facility created as above, IIT Delhi has faculty
with international level of expertise in the following areas.
• Electrical Machines & Drives
• Power Systems & load Management
• Power Electronics
• Fluid & Solid Machines
• Machine Dynamics
• Computers and Instrumentation
• Thermodynamics
• Air conditioning

Total solution to the Electricity consumption problem towards considerable energy saving can
be ensured by the above combination of infrastructure and expertise. After conducting Energy
Audit Studies, a comprehensive technical report suggesting specific actions would be provided
to the clients.

How to contact?
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS

Interested Organizations/ Individuals may send response form in the given format to make use of
this facility.

Energy Audit/ Energy Conservation Facility


at Jamia Millia Islamia

Response Form

Name :

Organization:

Address:

Tel No:

FAX:

E mail:

Nature of organization:

We are interested in “Power Quality and Energy Audit Studies to be carried out in our
organization.

Typical problem to be studied if any:

(Signature)

Send to :
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS

Dr. V. K. Sharma (Reader)


Dept of Electrical Engineering
Faculty of Engg. & Technology
Jamia Millia Islamia, New Delhi-110025
Tel No : 26982651

The scope of proposed energy audit work shall include

1. Review of plant electrical demand and evaluate the possibility of improving power factor.
2. Assessment of pump performance in order to improve its energy efficiency.
3. Total Load Survey
4. Power Quality Information including Harmonics
5. Study of Lighting Load measurement and examine the feasibility of incorporating the energy
efficient lighting to reduce the unit consumption in the campus.
6. Review and development of management information system for effective monitoring of total
energy consumption to attain an optimum value through implementation of necessary
corrective measures.