Laboratory Mikronix Associates, W-10, M.I.D.C.

Area, Chikalthana, Aurangabad,


Maharashtra
Accreditation Standard ISO/IEC 17025: 2005
Certificate Number CC-2102 (in lieu of C-0057) Page 1 of 3
Validity 20.04.2017 to 19.04.2019 Last Amended on --

Sl. Quantity Measured / Range/Frequency *Calibration Measurement Remarks


Instrument Capability (±)

MECHANICAL CALIBRATION

I. DIMENSION (BASIC MEASURING INSTRUMENT, GAUGE ETC.)

1. Length Upto 25 mm 0.07 µm Using Std. Slip Gauge


Slip Gauges$ 25 mm to 50 mm 0.08 µm Block/Gauge Block
(Tungsten Carbide) 50 mm to 75 mm 0.10 µm Calibrator by Comparison
75 mm to 100 mm 0.12 µm Method
100 mm to 250 mm 0.40 µm Using Std. Long Slip
Gauge & Gauge Block
Calibrator by Comparison
Method

2. Length Upto 25 mm 0.12 µm Using Std. Steel Slip


Slip Gauges/ 25 mm to 50 mm 0.15 µm Gauge/ Length Bar &
Length Bars$ 50 mm to 75 mm 0.20 µm Gauge Block Calibrator by
(Steel/Ceramic) 75 mm to 100 mm 0.24 µm Comparison Method

100 mm to 200 mm 0.53 µm Using Std. Steel Long Slip


200 mm to 300 mm 0.71 µm Gauge/ Length Bar &
300 mm to 400 mm 1.0 µm Gauge Block Calibrator by
400 mm to 500 mm 1.13 µm Comparison Method
500 mm to 1000 mm 2.90 µm

3. Length 0 to 25 mm 0.9 µm Using Electronic Probe &


Slip Gauge Gauge Blocks with
Accessories$ Comparator
Stand
Flatness Upto Length & Diameter 0.7 µm Using Flat Base &
100 mm Electronic Probe

Rajeshwar kumar Avijit Das


Convenor Program Director
Laboratory Mikronix Associates, W-10, M.I.D.C. Area, Chikalthana, Aurangabad,
Maharashtra
Accreditation Standard ISO/IEC 17025: 2005
Certificate Number CC-2102 (in lieu of C-0057) Page 2 of 3
Validity 20.04.2017 to 19.04.2019 Last Amended on --

Sl. Quantity Measured / Range/Frequency *Calibration Measurement Remarks


Instrument Capability (±)

4. Length 0 to 300 mm 1.50 µm Using Gauge Blocks &


Caliper Checker/ 0 to 600 mm 2.52 µm Linear Height Gauge
Step Gauge/ 0 to 1000 mm 4.10 µm Measuring Instrument
Depth Checker$ by Comparison Method

5. Length
Gauge Block
Calibrator#
L.C.: 0.01 µm 0.5 mm to 100 mm 0.03 µm Using Gauge Blocks
L.C.: 0.1 µm 100 mm to 1000 mm 0.16 µm “Grade K”

6. Length 0 to 20 mm 0.6 µm Using Gauge Blocks &


Measuring Pins$ Horizontal Length
Measuring Machine

7. Length
Electronic Probe$
(LVDT)
L.C.: 0.01µm 0 to 10 µm 0.10 µm Using Slip Gauge Blocks
L.C.: 0.1µm 0 to 200 µm 0.12 µm

8. Length
Horizontal Length
Measuring Machine$
L.C.: 0.1 µm 0 to 25 mm 0.25 µm Using Slip Gauge Blocks

9. Angle Upto 45° 2.9" of arc Using Gauge Block &


Angle Gauge$ Upto 90° 2.7" of arc Special Fixture by
Trigonometric Method

10. Squareness$ 0 to 300 mm 1.0 µm Using Gauge Block


Calibrator / Right Angle
Fixture with Electronic
Probe

Rajeshwar kumar Avijit Das


Convenor Program Director
Laboratory Mikronix Associates, W-10, M.I.D.C. Area, Chikalthana, Aurangabad,
Maharashtra
Accreditation Standard ISO/IEC 17025: 2005
Certificate Number CC-2102 (in lieu of C-0057) Page 3 of 3
Validity 20.04.2017 to 19.04.2019 Last Amended on --

Sl. Quantity Measured / Range/Frequency *Calibration Measurement Remarks


Instrument Capability (±)

11. Length
Gauge Block
Calibrator♣
L.C.: 0.01 µm 0.5 mm to 100 mm 0.03 µm Using Gauge Blocks
“Grade K”

* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%


$
Only in Permanent Laboratory

Only for Site Calibration
#
The laboratory is also capable for site calibration however, the uncertainty at site depends on the
prevailing actual environmental conditions and master equipment used.

Rajeshwar kumar Avijit Das


Convenor Program Director

Вам также может понравиться