Вы находитесь на странице: 1из 3

RTDs

RTD Specifications
One of the most important industrial process variables is temperature which affects the quality of product and the
safety of the installation. There is no single sensor which is equally suitable for all applications, so sensors of different
sizes are manufactured by different production methods. Therm-x uses the highest qualty Resistance elements in the
manufacturing of our sensors.

Tolerances
the platinum sensor Pt 100 is defined by the international Standard lEC 751. This definition covers the characteristics
and two tolerance classes, Class A and Class B. The permitted error limit increases with the measurement tempera-
ture. Each class consists of a tolerance on the nominal value (resistance at 0.0C )and a deviation depending on
temperature. Class tolerances are tested in the element form. Packaging and lead terminations affect the stated
tolerance. Therm-x standard assemblies incorporate thin film elements conforming to IEC class B. Controlled assem-
bly procedures are utilized to minimize packaging effects to tolerances. Special tolerances and N.I.S.T. certifications
are available upon request for a nominal charge. See page 9 for calibration services offered.
For a Class A sensor the following relationship applies where “T” is the absolute temperature:
rT=±(0.15+0.002 * t) For t =75 0C, the tolerance is therefore: rT=±(0.15+0.002 * 75)=±0.30C
For a Class B sensor the following relationship applies:
rT= ±(0.3+0.005 * t). In the above example the deviation is therefore: rT= ±(0.3 + 0.005 * 75) = ±0.675 0C
For applications where closer tolerances are required, detectors are available in the following band tolerances

Band Ohms
1 .1 (Standard)
2 .05
3 .03
4 .02
5 .01

Design
Thin film elements have a sensitive plati-
num film deposited onto the ceramic
former. These types offer smaller dimen-
sions and the possibility for higher nomi-
nal resistances. Wire wound ceramic ele-
ments consist of a ceramic body having
the heat sensitive resistance wire encap-
sulated into longitudal bores.

Characteristic
All versions described conform to the ba-
sic values and tolerances of DIN IEC 751
for platinum sensors. Sensors with 5 or 10
times the nominal value of 100 Ohm have
the electrical tolerances increased by a fac-
tor of 5 and 10 respectively.
Stability
Compared with other temperature sensors,
PT precision resistance elements possess
good long term stability at the upper appli-
cation limit.

26 1-510-441-7566 1-800-9-THERM-X THERM-X of California


RTDs
Industrial Process
Protection Head

“A” “B”

D - IP - - - - -

Probe Style
Industrial Process ....... IP Transmitter Option
Omit if none needed. See ordering
information on next page.
Fittings
See Table “B” on next page for
ordering code. 1/2” x 1/2” NPT “B” Lead Length
SS fitting (code “A”) is standard.
(Omit for probes with heads)
XX ........... Specify in inches
Element
Din 385 Class A 100 ohm ............. A Lead Option
Din 385 Class B 100 ohm ............. B (Omit for probes with heads)
Din 385 Class A 1000 ohm ............ C 3TT ....... Teflon Jacket 3 Wire
Din 385 Class B 1000 ohm ............ D 4TT ....... Teflon Jacket 4 Wire
JIS 391 Class A 100 ohm .............. E (Omit for probes with heads)
2IT ........ Individual Teflon 2 Wire
JIS 391 Class B 100 ohm .............. F 3IT ........ Individual Teflon 3 Wire
JIS 391 Class A 1000 ohm ............ G 4IT ........ Individual Teflon 4 Wire
JIS 391 Class B 1000 ohm ............ H 3GG ...... Fiberglass Jacket 3 Wire
4GG ...... Fiberglass Jacket 4 Wire
Diameter (inches)
1/8” ............... 18
3/16” ............ 316 Termination
1/4” ............... 14 ST .... Stripped Leads, 36” teflon
5/16” ............. 516 leads are standard
CA ... Cast Aluminum Head
“A” Sheath Length CI ..... Cast Iron Head
Specify in inches ............. XX NY ... Nylon Head Black
PW ... Polypropylene Head White
EX ... Explosion Proof Head
•Standard probe assemblies use 1/2”x1/2” NPT SS fitting brazed.
Welded construction is available. Use order code “C”
•Spring loaded assembly is not sealed at process fitting.

• 3-wire teflon is standard for head termination.

THERM-X of California 1-510-441-7566 1-800-9-THERM-X 29


RTDs
Industrial Process (Cont’d)
Transmitter option; 1. I = Isolated or N = Non-isolated 2. & 3. Temp. Range (see table A below) 4. °C or °F

Example; I 0 100 C = Isolated, 0-100 degrees C = 4-20mA

Non-isolated Isolated
Input: PT100 .00385 3-wire RTD PT100 .00385 3 or 4-wire RTD Table A
Adjustable to specific ranges within -328 to 1832°F / -200 to 1000°C Standard Ranges
Range:
-60 to 1120°F / -50 to 550°C Narrowest range = 18°F / 10°C
RTD
Output: 4-20mA 4-20mA or 20-4mA

Ambient -50 - 50°C


-40 to 185°F / -40 to 85°C -40 to 185°F / -40 to 85°C
Temp.:
0 - 100°C
Power Supply: 6.5 to 32 VDC 6.5 to 36 VDC

Polarity 0 - 150°C
Yes Yes
Protection
0 - 100°F
Accuracy: ± 0.1% of span ± 0.1% of span

Calib. 0 - 300°F
± 0.1% of span max. of 0.2°C or 0.1% of span
Accuracy:
0 - 400°F
Long Term
± 0.1% of span/year ± 0.1% of span/year
Stability Consult sales for other ranges
Connection: up to 12 Awg. wire up to 16 Awg. wire

Table B FITTINGS
NPT
Material Sheath OD Order Code
Thread

1/2"x1/2" 316SS .125" to .313" A

1/2"x1/2" 316SS .125" to .250" *B

1/2"x1/2" 316SS .125" to .313" **C

1/2" Single 316SS .125" to .313" D

1/4"x1/4" 316SS .188" to .250" E

1/4" Single 304SS .062" to .250" F


Standard orientation for single threaded fittings is
1/8" Single 304SS .062" to .250" G
threads facing process. Add “X” after fitting order
* Spring Loaded Assembly code for backwards fitting (threads facing lead end).
** 316SS welded fitting

P R I C I N G

*Basic 1/8" 3/16" 1/4" 5/16"


• Standard assemblies use Class B thinfilm (includes 1st 12" of sheath) $65 $63 $60 $68
elements and are rated from -50°C (-58°F)
Add'l Sheath Adder
to +260°C (500°F). Higher temperature rated (per inch) .15 .25 .45 .75
assemblies are available up to 400°C
(752°F). Add “-HT” to p/n suffix. Element Adder
A B C,E,G,H D,F

$5 N/C $6 $2

CA,CI NY PW EX
Protection Head Adder
$26 $22 $25 $55
Discount Schedule
A B C,F,G D E
1 - 9 units Net Fitting Adder
N/C $20 $5 $4 $9
10 - 24 units 10% 2IT 2TT,3IT
3TT,
4IT
4TT,
Lead Option Adder (per foot) 3GG 4GG
25 - 49 units 20% (first 36" included in basic)
.30 .50 .65 .65 .70
50 and up Call
Transmitter option add $99 for nonisolated or $189 for isolated.

30 1-510-441-7566 1-800-9-THERM-X THERM-X of California