Features
Input: RS-232 protocal Power requirements: +10V ~ 30VDC
Output: RS-485 protocal (two wire, D+, D-) Power consumption 2.2W(max)
RS-422 protocal Dimension: 7cm * 10cm * 2cm
Speed: “AutoPro” designed
Auto switching baudrate, 300-115200 Bps Serial products:
256 modules max. in one RS-485 network without repeater
3000V opto-isolation 422 485 Isolate Repeater
Mulitple Baudrate; Mulitple Data Format EX9520 ˇ 232
EX9520R ˇ 485
Communication distance: EX9520A ˇ ˇ 232
2.1 Km/9600 Bps EX9520AR ˇ ˇ 422/485
2.7 Km/4800 Bps EX9510 ˇ 485 ˇ
3.6 Km/2400 Bps Jumper Setting (For EX9520A/AR)
JP1: PIN 2,3 for RS485 EX9510A ˇ ˇ 422/485 ˇ

PIN 1,2 for RS422

Ref. Of Connection I:
External power
GND 24V

GND(B) 10 TX-
+Vs(R) 9 TX+
RS422 device
8
COM1/2/3/4

RX-
(RXD) RX- 7 RX+
(RS422)

RX+ 6
(TXD)
UART

TX- 5 6 INIT*

EX9000 Series
15
Host

TX+ 4 7 D+ 14
(GND)
3 Rs485 8 D- 13
(RS485)

RS232C Signal
Signal D- 2 9 +Vs(R) 12
D+ 1 10 GND(B) 11
Note: JP1 of 9520A/AR is selectable for RS485 or RS422

Ref. Of Connection II:


EX9000
EX 9520/A/R/AR Series EX 9510
RS232 to RS485 R S 485 Repeater
3000V isolation 3000V isolation
RS485 RS485 RS485
Host
PC/PLC 256 Modules
RS 232 W/O Repeater
EX9510

{ is Terminator }

EX9000 EX9000 EX9000 EX9000


Series Series Series Series
Note: If the length of RS 485 Network is about 1.2km, try 110 Ώ first.
If the length of RS 485 Network is about 600m, try 220Ώ first.
If the length of RS 485 Network is about 300m, try 330Ώ first.
support@d-d-s.nl www.ddszevenbergen.nl
PC Network: Note : Every remote-PC must have a unique address.

HOST Remote Remote

256 Remote
PC W/O Repeater

RS232
RS232

RS232
EX9510

EX9510
EX9520 EX9000 EX9520 EX9000 EX9520
Series Series RS485

R S 485 256 Modules W/O E X 9510

PLC Network:
HOST

D+ power D+ power D+ power


PLC PLC PLC
RS232

RS232

RS232
RS232

EX9520R EX9520R EX9520R


EX9520 256 PLC W/O
Repeater EX 9510

R S 485 R S 485
EX9510

RS232 Devices Network: Note : 1. Every device must have a unique device address.
2.It will not send out a RS-232 signal if the destination address
does not match with the device address.
HOST
RS232 Device RS232 Device
RS232

256 RS 232 Device W/O


RS232
RS232

Repeater EX9510

EX9520 EX9520R EX9000 EX9520R


Series
R S 485
support@d-d-s.nl www.ddszevenbergen.nl
EX9520 Isolation=3000Vdc

T D+
RS-232 AutoPro RS-485
R
GND
D-

5V
Isolation in DC DC V+
RS-232 site DC 0V DC
V-

EX9520A Isolation=3000Vdc
D+
RS-485
T
RS-232 AutoPro D-
R
Tx +/-
GND RS-422
Rx +/-

5V
Isolation in DC DC V+
RS-232 site DC 0V DC
V-

support@d-d-s.nl www.ddszevenbergen.nl
EX9520R Isolation=3000Vdc

T D+
RS-232 AutoPro RS-485
R
GND
D-

V+ 5V
DC DC Isolation in
V- DC 0V DC RS-485 site

EX9520AR Isolation=3000Vdc
D+
RS-485
T
RS-232 AutoPro D-
R
Tx +/-
GND RS-422
Rx +/-

V+ 5V
DC DC Isolation in
V- DC 0V DC RS-422/485 site