Вы находитесь на странице: 1из 2

Calculation of equivalent flange pressure due to external loads https://www.cis-inspector.com/asme-code-calculation-equivalent-flange-...

Home Service Seminars ASME Code Forum Contact EN

Online Calculation-Tools Calculation of equivalent flange pressure due to external loads


Print

internal pressure P: bar


- ASME Code - Allowable Stresses

Stress Values- Section II, Table 1A eff. gasket diameter G: mm

Stress Values- Section II, Table 1B


axial force Fax: N
Stress Values- Section II, Table 3
Moment M1: Nm
Carbon Steel - Example

High Alloy Steel - Example


Moment M2: Nm

- Shells and Heads


Intermediate Results
Cylinder under internal pressure
resulting moment: Mres = √(M12+M22) = 13038.4 Nm
Elliptical head under internal pressure
pressure (moment): Pm = 16*Mres/(π*G3) = 0.118 MPa
Torispherical head under internal pressure

Klöpperboden (DIN28011) under internal pressure


pressure (force): Pr = 4*Fax/(π*G2) = 0.2018 MPa

Korbbogenboden (DIN28013) under int. pressure


Results
Hemispherical head under internal pressure

Flat head (circular) under internal pressure


equivalent
Flat head (noncircular) under internal pressure 3.1983 bar > 0
pressure Peq:

- Flanges

Equivalent flange pressure due to ext. loads total


23.4983 bar
pressure Ptot:
Loose-type flange under internal pressure

ASME B16.5 Flanges


Input Errors

- Determination of foming strains

Forming strain of a cylinder

Forming strain of a head

Forming strain of tube or pipe bends


General Information:

If you have further questions please contact us directly or start a discussion in our ASME Code Forum. To
Tips and Tricks stay informed about any changes and amendments to our websites, upcoming seminars and the latest

1 of 2 9/17/2018, 7:49 PM
Calculation of equivalent flange pressure due to external loads https://www.cis-inspector.com/asme-code-calculation-equivalent-flange-...

Why not join one of our ASME Code information about the ASME Code, please feel free to subscribe our newsletter.
design workshops in:
These calculation tools are intended to be used for information and guidance only, they do not
replace a detailed design calculation and compliance with all applicable Code requirements. CIS
December 2018 GmbH expressly disclaims liability for errors and omissions in the contents of this site.
Brussels, Belgium
(English)

October 2018
Hamburg, Germany
(German)

Imprint | Contact | phone +49 201 74 72 75-0 | service@cis-inspector.com © CIS GmbH

2 of 2 9/17/2018, 7:49 PM