Be sure to turn off the circuit breakers of the machine and the main power source before operation.
All power supply specifications can be changed by changing connections of the power supply terminal in the
control box, connecting terminal, and terminal TA1 on power PCB 1 and changing connectors (J66 and J67).
V30 V50
TA1
Power PCB 1
1/6
5002 5002
Changing the Specifications
V100
TR Connecting
TA1
Power PCB 1
Power
supply terminal
2/6
5002 5002
Changing the Specifications
1. Wiring changes
V30 V50,V100
3/6
5002 5002
Changing the Specifications
TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
B
S T2 200 220 240V P66 P66
C 208V 230V
R T3
D 0
S T4
F
T5
J67 J66 200/208
H
T6
E TR
220/230
U AC100V 240
P65
V
P65
J65
TA1 J/P60
U 240
V
AC100V
P65 P65
Memo
Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).
A
T1
L C
L1(L) R T3
B
T2
N D
L2(N) S T4
L3 T
N N
E Connecting terminal
4/6
5002 5002
Changing the Specifications
TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
C
S T2 200 220 240V P66 P66
B 208V 230V
R T3
D 0
T T4
F
T5 J67 J66 200/208
H
T6
E TR
220/230
U 240
P65 AC100V
V
P65
J65
TA1 J/P60
U 240
V
AC100V
P65 P65
Memo
Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).
A
T1
L1 B
L1(L) R T3
L2 C
L2(N) S T2
L3 D
T4
L3 T
N N
E Connecting terminal
5/6
5002 5002
Changing the Specifications
TA1 J/P60
A
R T1
P67 P67 P67 200-210V 220-240V
C
N T2 200 220 240V P66 P66
B 208V 230V
S T3
D 0
N T4
F
T T5
J67 J66 200/208
H
T6
E TR
220/230
U AC100V 240
P65
V
P65
J65
TA1 J/P60
U 240
V
AC100V
P65 P65
Memo
Be careful that the positions of P66 (200-210V) and P66 (220-240V) in V30/50
(J340008) are opposite to the positions in V100 (J340038).
L1 A
L1(L) R T1
L2 B
L2(N) S T3
L3 F
L3 T T5
C
N T2
N N D
T4
E Connecting terminal
6/6
5011 5011
Changing the Specifications
Do not put your hand close to the gear. Your hand may be trapped. If your hand or something is trapping,
ask someone near by to turn off the circuit breaker of this machine as soon as possible.
Screws
50 Hz
(V30,V100: 30T
V50: 24T ) 60 Hz
( V30,V100: 25T
V50: 20T )
Reducer
Memo
The above figure shows the drive transfer gear direction for 60 Hz.
1/2
5011 5011
Changing the Specifications
6. The connector wiring of the dryer fan only for V100 must be changed.
Wiring cover
Screws
To power PCB 1
J130
P130 P130
50Hz 60Hz
Dryer fan
2/2