Вы находитесь на странице: 1из 15

BreezeMAX 3000 Technical

Specification

Release 5.0

Alvarion Ltd. All rights reserved.


The material contained herein is proprietary, privileged, and confidential. No disclosure thereof shall be made
to third parties without the express written permission of Alvarion. Alvarion reserves the right to alter the
specifications in this publication without prior notice.

Alvarion Ltd www.alvarion.com


-1-
Radio & Modem.................................................................................. 3

General Parameters ...................................................................... 3

Networking ......................................................................................... 5

Voice.................................................................................................... 5

Networking Gateway CPE................................................................. 6

Voice Gateway CPE........................................................................... 7

Data Communications....................................................................... 8

Indoor to Outdoor Communications ............................................... 8

Subscriber unit ............................................................................... 8

Base station ................................................................................... 8

Interfaces .....................................................................................10

Electrical ...........................................................................................11

Subscriber Unit ............................................................................11

Modular Base Station Equipment ................................................11

Micro Base Station Equipment ....................................................11

Mechanical........................................................................................11

MTBF .................................................................................................14

Environnemental..............................................................................15

Standard Compliance......................................................................15

Alvarion Ltd www.alvarion.com


-2-
Radio & Modem
General Parameters
Parameter Value
3.3GHz: (Excluding 7MHz)
Band e: UL: 3316-3335MHz; DL: 3366-3385MHz
Band f: UL: 3331-3350MHz; DL: 3381-3400MHz
Band g: UL: 3376-3400MHz; DL: 3300-3324MHz
Base 3.5GHz:
Station Band a: UL: 3399.5-3453.5MHz; DL: 3499.5-3553.5MHz
Band b: UL: 3450.0-3500.0MHz; DL: 3550.0-3600.0MHz
Frequency 3.6GHz:
Band a: UL: 3700-3753.5MHz; DL: 3600-3653.5MHz
Band b: UL: 3746.5-3800MHz; DL: 3646.5-3700MHz
3.3GHz:
Band e,f: UL: 3316-3350MHz; DL: 3366-3400MHz
CPE Band g: UL: 3376 - 3400MHz; DL: 3300-3324MHz
3.5GHz: UL: 3399.5-3500.0MHz; DL: 3499.5-3600.0MHz
3.6GHz: UL: 3700-3800MHz DL: 3600-3700MHz
Radio Access Method TDMA FDD
ETSI EN 301 021 V.1.6.1
Standard Compliance
ETSI EN 301 753 V.1.1.1
Channel bandwidth 7MHZ; 3.5MHz; 1.75MHz – software selectable
AU full duplex
Duplexing Technologies
SU half duplex
Central frequency
125KHz
resolution
BMAX CPE, BMAX PRO CPE:
o
17dBi typical, 20 , Vertical & Horizontal polarization, compliant
with EN 302 085, Class TS 3
BMAX PRO-SA:
o o
17 dBi typical, 18 AZ x 18 EL, vertical/horizontal polarization,
CPE Antenna
compliant with EN 302 085, V1.2.2 Range 1
BMAX CPE Si:
6 element beam switching antenna with typical 9dBi gain per
antenna
Optional external (WM) antenna with 12dBi gain.
CPE PRO:
N-type, 50 ohm
CPE Antenna Port
CPE Si:
SMA 50 ohm

Alvarion Ltd www.alvarion.com


-3-
256
104 sub-carriers for 1.75MHz channels
No. FFT points
208 sub-carriers for 3.5MHz channels
208 sub-carriers for 7MHz channels
FEC Convolution coding: 1/2, 2/3, 3/4
BST
AU: 28dBm±1dB
Nominal Output power AU HP 3.5GHz : 34dBm±1dB
(At antenna port) CPE
PRO CPE / PRO-SA: 20dBm±1dB
SUSI: 22dBm±1dB
With RTPC –40dbm
Max Input PWR
With out RTPC –10dbm
CPE ATPC Dynamic
>50 dB
Range

Alvarion Ltd www.alvarion.com


-4-
Networking
Services Macro BST Micro BST
Max number of service pipes per BST 4095 1023
Min number of data connections per Service 2 (1 uplink, 1 downlink) 2 (1 uplink, 1 downlink)
Pipe
Max number of data connections per Service 8 (4 uplink, 4 downlink) 8 (4 uplink, 4 downlink)
Pipe
Max number of data connections per SU 92 92
Max number of data connections per AU 3999 3999
Max number of SUs per AU 510 (1.75MHz; 3.5MHz) 250
250 (7MHz)
Max number of Sus per BST 2000 250
Max number of Aus per BST 7 1
Max number of MAC addresses in bridging NPU: 6000 (configurable 1000 (configurable aging
table aging time, default 10 time, default 10 minutes)
minutes)
SU: 512 (aging time 3
minutes)
Max number of VLANs per Service Pipe 16 16
Max number of VLANs per BST 1024 1024
Max number of concurrent calls per voice 10 10
service
Max number of MAC Addresses forwarded by 512 512
SU
Maximum packet size 1550 Bytes 1550 Bytes

Voice
Services Macro BST Micro BST
Maximum number of DRAP entities 510 250

Alvarion Ltd www.alvarion.com


-5-
Networking Gateway CPE
General Features
Routing Static Route, Dynamic Route (RIP1/2)
Firewall NAT Firewall with SPI mode
NAT Functionality NAT, Virtual Server, Special Application
DMZ Host
VPN IPSec, PPTP & LT2P Pass-Through
DHCP DHCP server for LAN and WLAN clients.
DHCP client for WAN
Wireless Features
Standard IEEE 802.11b / 802.11g
Data Rates 6/12/18/24/36/48/54Mbps in 802.11g mode
1/2/5.5/11Mbps in 802.11b mode
Operating Frequency 2.4GHz
Range Coverage Indoors - approx. 35-100 meters
Number of Channels America/ FCC: 2.412~2.462GHz (11 Channels)
Japan/ TELEC: 2.412~2.484GHz (14 Channels)
Europe/ ETSI: 2.412~2.472GHz (13 Channels)
Security WEP encryption – 64 Bit, 128 Bit, Wpa, 802.1x

Alvarion Ltd www.alvarion.com


-6-
Voice Gateway CPE
Interfaces
Ethernet LAN 1 10/100 Base-TX RJ45 connectors
Telephony 1 or 2 RJ11 connectors for analog telephones
Ethernet WAN (copper) 10/100 Base-TX RJ45 connector
Security
VLAN Separates data, management and telephone traffic
Authentication per call H235
Telephony and fax services
VoIP Protocol H.323, SIP
Internal Class 5 services Call Waiting, 3-party call, call alteration, differentiated ringing tones
External Class 5 services Activation of class 5 services supported by the IP-telephony system
G3 Fax T.38
Calling number identification FSK, DTMF
3rd party initiated pause and rerouting External rerouting of media stream during speech, e.g. for pre-paid
calling card and record announcement
DTMF In-band and out-band using H245 and H225 bi-directional
QoS for real-time services
Speech Codecs G711(support alaw & ulaw), G729ab
DiffServ Level 3 (IP) mechanism for handling QoS
Class of Service Level 2 (Ethernet) mechanism for handling QoS
General Adaptive Jitter buffer, echo cancellation, speech sampling 10-60 ms,
silence suppression
with comfort noise.
Flexibility & Service differentiation
Daisy chaining Up to 3 DRG units can be connected in series by daisy chain
Number of telephones Up to 5 analog telephones can be connected in series to each
telephone port
Regional Settings Properties Telephony signals, tones and cadences
Protocols and Standards
Complies with the following standards IPv4, TCP, UDP, RTP, DHCP, RTCP, SNMP, IEEE 802.1D, IEEE
802.1Q, IEEE 802.1P,
IEEE 802.2, IEEE 802.3, ICMP, HTTP, TFTP, NTP, H323v2/4, SIP
(RFC3261),
G.711, G.729ab, G.723.1, G.165, G.167, G.168, G3, FSK, DTMF

Alvarion Ltd www.alvarion.com


-7-
Data Communications

Data IEEE 802.3 CSMA/CD


VLAN support IEEE 802.1Q
Traffic Classification Layer 2 IEEE 802.1p, IP DiffServ Code Points DCSP
Traffic Prioritization IEEE 802.16a QoS air interface

Indoor to Outdoor Communications


Subscriber unit

Cable Type Category 5E, Outdoor Data Cable, Double Jacket, 4x2x24# FTP

Maximum Length 100 meter

Base station
IF Frequency Tx- 240MHz, Rx - 140MHz
Ref Synchronization Frequency 64MHz
Bi-Directional Control Frequency 14MHz
IF cable Impedance 50 ohm
Maximum IF cable Attenuation LP:
(Include MUX loss) 19dB @ 240MHz
15dB @ 140MHz
8dB @ 64MHz
HP 3.5GHz:
10dB @ 240MHz
7.5dB @ 140MHz
8dB @ 64MHz
Maximum IF cable DC Loop LP:
Resistance
4 ohm
HP 3.5GHz:
1.5 ohm

Alvarion Ltd www.alvarion.com


-8-
Recommended IF cable Double Shielded (Shielding effectiveness 90dB)
LP:
LMR195 @80 meter
LMR240 @ 150 meter
LMR400 @ 250 meter
HP 3.5GHz:
LMR195 @ 30 meter
LMR240 @ 60 meter
LMR400 @ 150 meter

Alvarion Ltd www.alvarion.com


-9-
Interfaces
Interface Indoor Unit Outdoor Unit
IF TNC jack, lightning protected TNC jack, lightning protected
ANT N-Type jack, lightning protected
(AU and SU external
antenna models)
Data, Voice, NPU: CPE:
Management Data: 100/1000Base-T (RJ-45) 10/100Base-T (RJ-45)
uBST:
Data: 10/100Base-T (RJ-45)
CPE:
Data: 10/100Base-T (RJ-45)
CPE SUSI:
Data: 10/100Base-T (RJ-45)

Voice: POTS (RJ11)


Management NPU & uBST: 10/100Base-T (RJ-45)
(out of band)
GPS NPU: 15-pin mini DIN
Time Base NPU: 15-pin mini DIN
Synchronization
External Alarm Input NPU & uBST: 9-pin mini DIN Requires future SW support
Alarm Output NPU & uBST: 9-pin mini DIN Requires future SW support
Power BS-PS: 48 VDC from indoor unit:
D-Type 3 Power pin male BST via the IF cable
Power Feeder: CPE via CAT5 cable
D-Type 3 Power pin male
CPE all types:
AC standard 3 pin cable
uBST:
DC model: D-Type 3 Power pin male
AC model: AC Standard 3 pin cable

Alvarion Ltd www.alvarion.com


- 10 -
Electrical
Subscriber Unit
Unit Details

Power Consumption BMAX PRO CPE: 22W


(IDU+ODU) CPE-SUSI : 9W
CPE-IDU Power Input 100-240 VAC, 47-63 Hz
CPE-ODU Power Input 54 VDC from the IDU over the indoor-outdoor Ethernet cable

Modular Base Station Equipment


Unit Details

Power Source -40.5 to -60 VDC


Full Base station (including 645W maximum for a fully equipped base station, including ODUs (1
ODUs) NPU, 6 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
Full Base station, including 868W maximum for a fully equipped base station, including 12 ODUs
2 ODUs per AU (1 NPU, 6 AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
Full Chassis (excluding 412W maximum for a fully equipped chassis, excluding ODUs
ODUs) (1 NPU, 6 AU-IDUs, 1+1 PIUs, 2+1 PSUs)
Base station with 4 AUs, 470W maximum for a chassis with 4 AUs, including 4 ODUs (1 NPU,
including 1 ODU per AU 4 AUs with 1 ODU per AU, 1+1 PIUs, 2+1 PSUs)
Base station with 4 AUs, 621W maximum for a chassis with 4 AUs, including 8 ODUs (1 NPU,
including 2 ODUs per AU 4 AUs with 2 ODUs per AU, 1+1 PIUs, 2+1 PSUs)
Chassis with 4 AUs 317W maximum for a chassis with 4 AUs, excluding ODUs
(excluding ODUs) (1 NPU, 4 AU-IDUs, 1+1 PIUs, 2+1 PSUs)
PIU 16W maximum
PSU 200W maximum output power
Efficiency: 75% minimum, 80% typical
NPU 65W maximum, 44W typical
2 Channel AU-IDU 38W maximum, 27W typical
4 Channel AU-IDU 46W maximum, 29W typical
AU-ODU
LP:

Alvarion Ltd www.alvarion.com


- 11 -
Unit Details

32W maximum, 27W typical

HP 3.5GHz:
95W maximum
AVU 24W maximum, 23W typical

Micro Base Station Equipment


Unit Details

AC model: 85 – 265 VAC, 47 – 63 Hz


Power Source
DC model: -40.5 to -60 VDC
2 Channel Micro Base
Station IDU Power 85W maximum
Consumption
4 Channel Micro Base
Station IDU Power 64W maximum
Consumption

LP:

32W maximum, 27W typical


AU-ODU Power
Consumption HP 3.5GHz :

95W

Mechanical
Product Dimensions (cm) Weight (kg)
Macro base station shelf 8U x 43.19 x 24 6.9 (excluding AVU)
Air Ventilation Unit (fan tray) 2U x 84HP x 16 1.7
Power interface module 3U x 5HP x 16 0.35
Power supply module 3U x 8HP x 16 0.7
Network processing module 6U x 7HP x 16 0.7
Access Unit indoor module 6U x 7HP x 16. 0.6
Access Unit outdoor radio without antenna 30 x 8.5 x 15.5 2.9

Alvarion Ltd www.alvarion.com


- 12 -
Access Unit outdoor radio HP without antenna 31.5 X 16 X 16 5.5
Micro Base Station 1U x 44.3 x 27.9 3.5
Power Feeder 15.7 x 14.6 x 3.17 0.6
Broadband data bridge indoor module 16 x 3.2 x 6 0.3
Networking gateway CPE indoor module 11.1 x 2.6 x 19 0.6
Voice Gateway 17.6 x 11 x 2.8 0.23
CPE outdoor radio unit with integrated antenna 30 x 10 x 30 3
CPE outdoor radio unit without antenna 30 x 8.5 x 15.5 2.3
CPE PRO outdoor radio unit with integrated antenna 30.5x30.5x7.5 2.4
CPE PRO outdoor radio unit without antenna 30.5x11.7x5.6 2
CPE PRO SA outdoor radio unit 21x21x5.4 1.25
CPE PRO SE outdoor radio unit 21x21x5.4 1.13
CPE SUSI indoor unit 17 x 17x 8 0.7
* 1U=44.45 mm (1.75”)
** 1HP=5.08 mm (0.2”)

Alvarion Ltd www.alvarion.com


- 13 -
MTBF
Part
Product Description MTBF
Number
Base Station
756,600
BMAX-BST-SH 735201 Base Station Shelf. Includes air ventilation unit (AVU)
(MTBCF)
BMAX-BST-PSU 735203 Base Station Power Supply Unit 704,733
BMAX-BST-NPU 735204 Network Processor Unit 212,213
BMAX-BST-PIU 735205 Base Station Power Interface Unit 1,579,428
756,600
BMAX-BST-AVU 735202 Base Station Air Ventilation Unit
(MTBCF)
BMAX-BST-PWR-FEED 735216 BreezeMAX Base Station Power feeder unit 1017727
Micro Base Station
735207/ 95,238
BMAX-MBST-IDU-2CH Micro Base Station Indoor Unit
735208 (MTBCF)
65,345
BMAX-MBST-IDU-4CH 735185 Micro Base Station Indoor Unit
(MTBCF)
Access Units
BMAX-BST-AU-IDU-2CH 735206 Base Station Access Unit interface module (2 channels) 271,091
BMAX-BST-AU-IDU-4CH 735170 Base Station Access Unit interface module (4 channels) 117,555
735210/
BMAX-BST-AU-ODU-3.5 Base Station Outdoor Radio Unit 292,195
735211
BMAX-BST-AU-ODU-3.5-
735214/5 Base Station Outdoor Radio Unit HP 157,133
HP Band A/B
CPE
BMAX-CPE-IDU-1D 735100 Subscriber Indoor Module with one 10/100 Base-T Data Port 1,119,151
BMAX-CPE-IDU-NG- Networking Gateway Indoor module with four 10/100 Base-T
735106
4D1W Ports + 802.11g wireless interface
735401/ Voice Gateway Indoor module with one 10/100 Base-T Data
ALVR-VG-1D1V > 300,000
735403 Port + one RJ11 POTS Port (H.323 or SIP P/N).
735402/ Voice Gateway (H.323) Indoor module with one 10/100 Base-T
ALVR-VG-1D2V > 300,000
735404 Data Port + two RJ11 POTS Port (H.323 or SIP P/N).

Alvarion Ltd www.alvarion.com


- 14 -
735110/
BMAX-CPE-ODU 735111/ Subscriber Outdoor Radio Unit 214,611
735112
735113/
BMAX-CPE-ODU-PRO 735114/ Subscriber PRO CPE Outdoor Radio Unit 282,844
735115
BMAX-CPE-ODU-PRO-S 735120/1 Subscriber PRO S CPE Outdoor Radio Unit 299,454
735150
BMAX-CPE-SUSI Subscriber SUSI CPE Indoor Radio Unit 400,593

Environnemental
Indoor Unit Outdoor Unit
0 0 0 0
Operating 0 C to 40 C -40 C to 55 C
Temperature CPE SUSI
0 0
-5 C to 45 C
Operating Humidity 5%-95% non condensing 5%-95% non condensing, weather
protected

Standard Compliance

Type Standard
EMC ETSI EN 301 489-1
Safety EN 60950 (CE), CB
IEC 60 950 US/C (TUV)
Environmental ETS 300 019
part 2-1 T 1.2 & part 2-2 T 2.3 for indoor & outdoor
part 2-3 T 3.2 for indoor
part 2-4 T 4.1E for outdoor
Radio ETSI EN 301 021 V.1.6.1
ETSI EN 301 753 V.1.1.1
MTBF Bellcore SR332 Issue 1

Alvarion Ltd www.alvarion.com


- 15 -

Вам также может понравиться