Dual-Band Combiner

1710 – 1880 MHz 1920 – 2170 MHz


GSM 1800 UMTS

• Designed for co-siting purposes


• Enables feeder sharing Port 3

• Can be used as a combiner near the BTS or Port 1


in a reciprocal function near the antenna
• Suitable for indoor or outdoor applications
• Wall or mast mounting
• Available as a single unit, or for XPol antennas
as a double unit Port 2

• Built-in lightning protection 793 423, 782 10243 793 424, 782 10244
Single Unit Double Unit

• 793 423: Single unit, DC by-pass between all ports


External DC stop available as an accessory
• 793 424: Double unit, DC by-pass between all ports
External DC stop available as an accessory
• 782 10243: Single unit, DC by-pass between ports 2 and 3
Built-in DC stop between ports 1 and 3
• 782 10244: Double unit, DC by-pass between ports 2 and 3
Built-in DC stop between ports 1 and 3

Single Unit 793 423 Single Unit 782 10243


Double Unit 793 424 Double Unit 782 10244
(only 1 unit shown) (only 1 unit shown)
Technical Data

Type No. 793 423 793 424 782 10243 782 10244
Single Unit Double Unit Single Unit Double Unit

Pass band
Band 1 (GSM 1800) 1710 – 1880 MHz
Band 2 (UMTS) 1920 – 2170 MHz
Insertion loss
Port 1 ↔ Port 3 < 0.3 dB (1710 – 1880 MHz)
Port 2 ↔ Port 3 < 0.3 dB (1920 – 2170 MHz)
Isolation
Port 1 ↔ Port 2 > 50 dB (1710 – 1880 MHz)
> 50 dB (1920 – 2170 MHz)
VSWR < 1.2 (1710 – 1880 / 1920 – 2170 MHz)
Impedance 50 Ω
Input power
Band 1 < 240 W
Band 2 < 240 W
Intermodulation products < –160 dBc (3rd order; with 2 x 20 W)
Temperature range –40 ... +60 °C
Connectors 7-16 female, long neck
Application Indoor or outdoor (IP 66)
Subject to alteration.

DC/AISG transparency
Port 1 ↔ Port 3 By-pass (max. 2500 mA) Stop
Port 2 ↔ Port 3 By-pass (max. 2500 mA) By-pass (max. 2500 mA)
Lightning protection 3 kA, 10/350 μs pulse
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight 3.2 kg 6.4 kg 3.2 kg 6.4 kg
936.1955/j

Packing size 362 x 262 x 139 mm 364 x 197 x 276 mm 362 x 262 x 139 mm 364 x 197 x 276 mm
Dimensions (w x h x d) 216 x 318 x 55 mm 216 x 318 x 127 mm 216 x 318 x 55 mm 216 x 318 x 127 mm
(including mounting brackets)

Internet: http://www.kathrein.de 793 423, 793 424, 782 10243, 782 10244 Page 1 of 2
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
Dual-Band Combiner
1710 – 1880 MHz 1920 – 2170 MHz
GSM 1800 UMTS

Accessories (order separately) Typical Attenuation Curves

Clamp Set 0

Attenuation/dB
Clamp set
Type No. suitable for mast 10
diameter of
20
734 360 34 – 60 mm 1710 – 1880 1920 – 2170
30
734 361 60 – 80 mm
40
734 362 80 – 100 mm
DC stop 50
734 363 100 – 120 mm
60
734 364 120 – 140 mm
70
734 365 45 – 125 mm
80

Type No. Description 50-Ω load 90

100
793 301 DC stop 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

784 10367 50-Ω load 1.5 W Frequency/MHz


indoor or outdoor

Attenuation/dB
0.5

1.0
1710 – 1880 1920 – 2170
1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0
1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
Frequency/MHz

Top view Side view Side view


793 423, 782 10243 Single Unit, 793 423, 782 10243 793 424, 782 10244
793 424, 782 10244 Double Unit Single Unit Double Unit

Please note: IP66 protection will be lost, and all corresponding guarantees will become null and void, if mounting brackets are removed or tampered with.
Upgrading from existing single units to double units is possible, but can only be carried out at Kathrein due to IP66 considerations.

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks
Subject to alteration.

that may arise when products are used under extraordinary operating conditions.

Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures),
may result in the breakage of a mast mounted device or even cause it to fall to the ground.

These facts must be considered during the site planning process.

The Dual-band Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and
have passed environmental tests as recommended in ETS 300 019-2-4.
936.1955/j

The installation team must be properly qualified and also be familiar with the relevant national safety regulations.

The details given in our data sheets have to be followed carefully when installing the antennas, filters, combiners, amplifiers and
accessories.

The limits for the coupling torque of RF connectors, recommended by the connector manufacturers must be obeyed.

Terminate unused inputs with a suitable 50-Ω load, e.g. 784 10367.

Any previous datasheet issues have now become invalid.

Page 2 of 2 793 423, 793 424, 782 10243, 782 10244 Internet: http://www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494