Fire Detection Systems

Product Catalogue 2016 | EMEA


Product Sheet | Detecon

Version 2016-01

Product Catalogue
Fire Detection Systems
The contents of this publication are subject to modifications without notice. All rights reserved.

This product catalogue is intended for sales purposes only. For


planning, installation, commissioning and operation, please refer to the
corresponding operating instructions, which are enclosed with the products.

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 1
Product Sheet | Detecon

Content Chapter - Page

Fire alarm and extinguishing control panels


FMZ 5000 base unit, FMZ 5000 mod S...........................................1 - 3
FMZ 5000 modules/cards, FMZ 5000 mod S .................................1 - 6
FMZ 5000 complete OU .................................................................1 - 10
FMZ 5000 base unit .......................................................................1 - 11
FMZ 5000 modules/cards................................................................1 - 22
FMZ 5000 enclosure/front plates.....................................................1 - 49
FMZ 5000 printer.............................................................................1 - 52
FMZ 5000 power supply units.........................................................1 - 55
FMZ 5000 batteries.........................................................................1 - 61
FMZ 5000 fire alarm panel accessories .........................................1 - 63
FMZ 4100 cards .............................................................................1 - 66

Fire brigade and system accessories


Fire brigade control panels..............................................................3 - 1
Fire brigade display panel...............................................................3 - 2
Graphic panel .................................................................................3 - 4

Manual call points


DMX indoor application, addressable..............................................4 - 3
DMX indoor application, conventional.............................................4 - 12
DMX indoor application, Ex.............................................................4 - 24
DMX indoor application, accessories..............................................4 - 27
DMX outdoor application, addressable ..........................................4 - 31
DMX outdoor application, conventional ..........................................4 - 38
DMX outdoor application, addressable, Ex ....................................4 - 45
DMX outdoor application, conventional, Ex ....................................4 - 47
DMX outdoor application, accessories ...........................................4 - 49
DMX accessories, general .............................................................4 - 50

Standard detectors
Optical smoke detectors, addressable............................................5 - 2
Ionisation smoke detectors, addressable .......................................5 - 3
Multisensor detectors, addressable.................................................5 - 4
Heat detectors, addressable ..........................................................5 - 5
Detector accessories, addressable.................................................5 - 6
Optical smoke detectors, addressable, Ex .....................................5 - 10
The contents of this publication are subject to modifications without notice. All rights reserved.

Ionisation smoke detectors, addressable, Ex .................................5 - 11


Heat detectors, addressable, Ex ....................................................5 - 12
Detector accessories, addressable, Ex ..........................................5 - 13
Optical smoke detector, conventional .............................................5 - 14
Ionisation smoke detectors, conventional ......................................5 - 15
Heat detectors, conventional ..........................................................5 - 16
Detector accessories, conventional.................................................5 - 18
Optical smoke detector, conventional .............................................5 - 20
Multisensor detectors, conventional ...............................................5 - 21
Heat detector, conventional ............................................................5 - 22
Detector accessories, conventional.................................................5 - 23

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 2
Product Sheet | Detecon

Content Chapter - Page

Optical smoke detector, conventional .............................................5 - 24


Multisensor detectors, conventional ...............................................5 - 25
Heat detector, conventional ............................................................5 - 26
Detector accessories, conventional.................................................5 - 29
Optical smoke detectors, conventional, Ex.....................................5 - 30
Ionisation smoke detectors, conventional, Ex.................................5 - 31
Heat detectors, conventional, Ex ....................................................5 - 32
Detector accessories, conventional, Ex .........................................5 - 34
Detector accessories ......................................................................5 - 35
Modules, addressable, DIN rail mounting ......................................5 - 38
Modules, addressable, wall mounting.............................................5 - 45
Modules, addressable.....................................................................5 - 54
Modules, conventional ....................................................................5 - 55
Test equipment ...............................................................................5 - 58
Test equipment, accessories ..........................................................5 - 65

Industrial detectors
UniVario IR flame detector..............................................................6 - 6
UniVario UV flame detector ............................................................6 - 8
UniVario Heat detector, standard ...................................................6 - 10
UniVario High temperature heat detector FS .................................6 - 12
UniVario High temperature heat detector FS Flex ..........................6 - 15
UniVario IR flame detector, Ex .......................................................6 - 17
UniVario UV flame detector, Ex ......................................................6 - 21
UniVario Heat detector, Ex standard...............................................6 - 22
UniVario High temperature heat detector FS, Ex............................6 - 28
UniVario High temperature heat detector FS Flex, Ex....................6 - 33
UniVario Detector accessories........................................................6 - 37
UniVario Test equipment ................................................................6 - 48
IR flame detector ............................................................................6 - 49
IR flame detector, Ex ......................................................................6 - 57
UV flame detector, Ex......................................................................6 - 61
Detector accessories ......................................................................6 - 62
Flame detector accessories ...........................................................6 - 67
Gas emisson detector ....................................................................6 - 68
Gas emission detector, Ex ..............................................................6 - 74

Aspirating smoke detectors


The contents of this publication are subject to modifications without notice. All rights reserved.

AMX 4004, basic devices ...............................................................7 - 1


AMX4004, detector heads...............................................................7 - 3
HELIOS AMX5000, basic devices...................................................7 - 4
HELIOS AMX5000, detector heads ................................................7 - 6
HELIOS AMX5000, accessories......................................................7 - 8
Vesda Laser, basic devices ............................................................7 - 9
Sampling pipes................................................................................7 - 12
Aspirating pipes - connections/accessories ...................................7 - 14
Aspirating tube system, mounting accessories ..............................7 - 15
Fittings ............................................................................................7 - 16
OneU®.............................................................................................7 - 22

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 3
Product Sheet | Detecon

Content Chapter - Page

Special detectors
Linear smoke detectors...................................................................8 - 1
Linear smoke detectors, accessories..............................................8 - 2
Cyklone montoring .........................................................................8 - 5
Cyklone monitoring, Ex ..................................................................8 - 6

Notification devices
Audible............................................................................................9 - 1
Audible, addressable ......................................................................9 - 12
Audible, Ex......................................................................................9 - 16
Visual ..............................................................................................9 - 22
Visual, addressable ........................................................................9 - 42
Visual, Ex .......................................................................................9 - 44
Audible/visual .................................................................................9 - 49
Audible/visual, addressable ............................................................9 - 62
Audible/visual, lighted warning display ...........................................9 - 65
Audible/visual, Ex ...........................................................................9 - 72

Door hold-open technique


TSZ 5000 ......................................................................................10 - 1
Holding solenoid ...........................................................................10 - 2
Anchor plate .................................................................................10 - 3
Hand switch ..................................................................................10 - 4

Cable/installation material
Cable/installation material............................................................. 11 - 1
The contents of this publication are subject to modifications without notice. All rights reserved.

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 4
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

FMZ 5000 – A fire alarm panel range for all safety concepts
Each FMZ 5000 model is a highly modern unit combining
fire alarm and extinguishing control in a fully modular
design with freely programmable controls to suit virtually
any project requirement.

Planning, operation and service made easy


The same hardware modules are used for both fire
detection systems and extinguishing systems, in three
different base unit layouts for wall-mounted installation or
in 19" free-standing cabinets. The MxSysCon configuration
program with full graphical user interface is used to adapt
those hardware modules to the specific project, in the office
or on site any time right up to the moment of startup.

Optimal value for money – you only buy what you


currently need
Changes in building use, in fire alarm controls or to your
fire protection system can be implemented easily in the
FMZ 5000 by replacing / adding / removing plug-in modules
and adapting the configuration. Rewiring within the fire alarm
panel is not required.

State of the art technology


- All modern functions of today's fire alarm and extinguishing control panels are combined in a single device:

• Clear display of alarms and other signals and easy operation in every
situation with the large graphical display screen and user menu interface.

• Loop technology for detection / control / monitoring with all modern features
and any number of branches - including explosion hazard areas.

• Operation of detectors for rough industrial environments in a wide range of operating


voltages for all fire characteristics (such as heat - smoke - flame - CO fire gas etc.),
also directly connected without couplers on the Loop.

• Up to 32 fire alarm and display/operating panels can be redundantly loop networked.

• Communication with building management systems or other control stations


The contents of this publication are subject to modifications without notice. All rights reserved.

via open interfaces or field bus protocols.

• The freely programmable user interface meets all requirements for the display
of messages and the controls to be executed in any logical and time combination.

• Redundant layout for fire detection and control of multi-zone extinguishing systems of any type.

• Easy adaptation to changing conditions of use and tasks through plug-in modules and graphical configuration.

A fire alarm panel system for universal application, with two VdS device approvals
G204124 fire alarm panel in accordance with EN54-2 A1 : 2006, EN54-4 A2 : 2006; 0786-CPD-20843
G205019 Electrical control device for multi-zone gas extinguishing systems in accordance with EN 12094-1 :2003; 0786 - CPD - 20222
301-410_019 / AI00_2015en

as well as activation and control of water extinguishing systems

• International approvals like FM, CCC, RU for all main markets.

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 1
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Additional and alternative components of the FMZ 5000 mod S


Additional and alternative components for FMZ 5000 mod S

FMZ 5000 mod S


909222

Fire brigade periphery


909365 FDP 3000 mod S
908148
12 V/12 Ah - 18 Ah
FCP 2003 mod S
910530

RT fire
alarm Relay card 8 TQ Relay card 8
Key locker
800843 802587

Cable set
913673
Communication
909367 Control centers Impulse valve reset
Printer 908324 Deluge valve

MxNet*
904877

MxNet

Spark test card


909366
The contents of this publication are subject to modifications without notice. All rights reserved.

* Available
* Available
ononrequest
request
301-010_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 2
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod S Part no.: 909222

Compact control panel of the FMZ 5000 control panel


family accommodated in a wall housing. For operation
of conventional detectors in standard design or suitable
for industrial applications and for the monitored triggering
of alarm devices, valves and release devices.
Optional modules allow for the additional connection
and operation of:
- Two transmission devices for fire and fault, one fire
brigade control panel, fire brigade display panel and
fire brigade key deposit box
- Interfaces for the data transfer to management systems,
printer, control panel networks and remote diagnostics
- Test of installed spark detectors during operation
Application - Relay card RK8 or RK8TQ
Use as fire detection and extinguishing control panel in
single-zone water or gas extinguishing systems, as spark
detection and spark extinguishing control panel as well as Product features
in applications with undelayed fire detection, such as for • 6 detector groups for any type of conventional
the protection of machines or paint shops. detectors, thereof 4 for undelayed fire detection
• 3 control groups
• 8 open collector outputs for connecting relays
Technical specifications • Collective and individual LEDs, partly red/yellow
Mains voltage 115 V / 230 V AC -10% +15% • Extendable by function modules
Mains frequency 50 Hz - 60 Hz - Fire brigade periphery for connection
of all kind of fire brigade components
Operating voltage 26.5 V DC - Communication card for connection to
Power supply unit 26.5 V DC / 3 A external control facilities and printers
Quiescent current approx. 250 mA - Spark test card for connection of spark test
detectors for testing spark detectors
Battery capacity 12 Ah and 18 Ah
• Suitable for integration into a ring network
External control voltage 26.5 V DC
with further Minimax control panels
Collective relays Fire / fault in each case
• Large fully graphic LC display with menu navigation
Contact load 1 A / 30 V DC, 0.5 A / 125 V AC
• Key switch as access to the direct
Max. switching capacity 30 W / 62.5 VA operation of detector and control groups
-5 °C to +55 °C
Ambient temperature
(+23 °F to +131 °F)
Relative humidity max. 95 %
Included in delivery
(IEC 721-3-3) Control panel with display and operating front panel,
The contents of this publication are subject to modifications without notice. All rights reserved.

no condensation
mainboard with power supply, conventional groups, control
Enclosure Sheet steel
groups and open collector outputs, wired ready for operation.
440 x 595 x 171 mm (WxHxD) Operating manual, log book, mounting material
Dimensions approx. body
17.3 x 23.4 x 6.7 inch (WxHxD)
Key, switch 911745
IP rating (EN 60529) IP 54 Key, door 767588
Colour RAL 7035

Weight
approx. 12.6 kg (27.8 lbs) Not included in delivery
without batteries Relaycard RK8 802587
Mounting Wall-mounted installation RK8TQ 800843
Cable set FMZ 5000 mod S 913673
Installation material, function modules, batteries
301-410_001 / AI01_2016en

Approvals / marking
G 211052 0786-CPD-21081
G 211123 0786-CPD-21136

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 3
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 Base unit

Fire alarm panel FMZ 5000 mod S SUZ NEW Part no.: 918077
Fully programmed monitoring control panel for 6 detector
groups. Components of sprinkler system as pressure
switches, temperature switches, limit switches and level
switches can be connected to the control panel.
Optional relay card RK8TQ or RK8 from the accessory
range. Customer made labelling is possible on request.

Application Product features


Use as monitoring panel for sprinkler systems. • 6 detector groups for monitoring sprinkler systems
• 8 open collector outputs for connecting relays
• Collective and individual LEDs, yellow
• Large fully graphic LC display with menu navigation
Technical specifications • Key switch as access to the direct
Mains voltage 115 V / 230 V AC -10% +15% operation of detector and control groups
Mains frequency 50 Hz - 60 Hz
Operating voltage 26.5 V DC
Power supply unit 26.5 V DC / 3 A
Quiescent current approx. 250 mA
Battery capacity 12 Ah/30h and 18 Ah/72h
External control voltage 26.5 V DC
Included in delivery
Collective relays fault in each case Control panel with display and operating front panel,
Contact load 1 A / 30 V DC, 0.5 A / 125 V AC mainboard with power supply, conventional groups, control
groups and open collector outputs, wired ready for operation.
Max. switching capacity 30 W / 62.5 VA
Operating manual, log book, mounting material, connection
Ambient temperature -5 °C to +40 °C (+23 °F to +104 °F) diagram.
Relative humidity max. 95 %
(IEC 721-3-3) no condensation Key, switch front panel 911745
Key, switch door 767588
Enclosure Sheet steel
2 Batteries 12V/12Ah 761677
440 x 595 x 171 mm (WxHxD)
Dimensions approx. body
17.3 x 23.4 x 6.7 inch (WxHxD)
Not included in delivery
Technische Änderungen ohne vorherige Ankündigung vorbehalten. Alle Rechte vorbehalten.

IP rating (EN 60529) IP 54


Relay card RK8 802587
Colour RAL 7035 RK8TQ 800843
approx. 12.6 kg (27.8 lbs) Cable set FMZ 5000 mod S for RK8TQ and RK8 913673
Weight
without batteries Installation material:
Mounting Wall-mounted installation Limit switch black 880214
red 790400
Pressure switch PMÜ-3 792183
PMÜ-10 810564
Float switch for:
Monitoring of liquids as air water pressure vessel,
Approvals / marking open water storage tank 879475
301-410_021 / AI00_2016en

G 211052
Monitoring of pump house 842358
0786-CPD-21081
G 211123 0786-CPD-21136

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Kapitel 1 - 4
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod S CA VK Part no.: 918493


Compact control panel of the FMZ 5000 control panel
family accommodated in a wall housing. The housing
is also suitable for flush-mounted installation in a wall
or console. For operation of conventional detectors in
standard design or suitable for industrial applications
and for the monitored triggering of alarm devices, valves
and release devices. By using the relay card RK8TQ system
signals can be forwarded.

Application Product features


Use as fire detection and extinguishing control panel • 6 detector groups for any type of conventional detectors,
for controlling chemical extinguishing systems. thereof 4 instantaneous fire detection
• 3 control groups
• 8 open collector outputs for connecting relays
Technical specifications • Collective and individual LED‘s, partly red/yellow
Mains voltage 115 V / 230 V AC -10% +15% • Large fully graphic LC display with menu navigation
Mains frequency 50 Hz - 60 Hz • Key switch as access to the direct operation of detector
and control groups
Operating voltage 26.5 V DC
Power supply unit 26.5 V DC / 3 A
Quiescent current approx. 250 mA DC
Battery capacity, max. 12V / 12 Ah
External control voltage 26.5 V DC
Included in delivery
Collective relays fire / fault in each case Control panel with display and operating front panel,
Contact load 1 A / 30 V DC, 0.5 A / 125 V AC mainboard with power pack, conventional control groups
and open collector outputs, wired ready for operation.
Max. switching capacity 30 W / 62.5 VA
Operating manual, log book, mounting material.
-5 °C to +55 °C Key, switch 911745
Ambient temperature
+23 °F to +131 °F Key, door 767588
Relative humidity max. 95 % Relay card RK8TQ 800843
(IEC721-3-3) no condensation
Enclosure Sheet steel
Dimensions approx. 440 x 500 x 116 mm (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Body 17.3 x 19.7 x 4.6 inch (WxHxD)


464 x 515 x 17 mm (WxHxD)
Body door 18.3 x 20.3 x 0.7 inch (WxHxD)
IP rating (EN60529) IP 42
Colour RAL 7035
approx. 10.6 kg (23.4 lbs)
Weight
without batteries
Mounting Wall-mounted installation

Approvals / marking
301-410_017 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 5
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 mod S communication card Part no.: 909367


Function module for installation into a FMZ 5000 mod S
with data interfaces for communication with other devices
or networking with other control panels.
One interface corresponds to the RS-232 standard with
freely configurable interface parameters.

Product features Application


• RS-232 interface with 9-pole Sub-D female connector Interface for data communication and message transmission.
• The interface parameters are adjustable through • Data transfer to PCs or control centers via Mx2 protocol
configuration • Connection of a printer for printout and logging
• For both interfaces, data transfer is also possible by messages and statuses. Printer types selectable
means of converters via fibre optic cables through configuration
• Connection of a module FMZ 5000 MxNet for integrating
the FMZ 5000 mod S in the path-redundant control panel
MxNet ring network
Technical specifications
Operating voltage 26.7 V DC Included in delivery
(Ethernet on) 10 mA DC Module ready for installation including fastening material
Quiescent current
(Ethernet off) 30 mA DC
Data interfaces 1 RS-232 Not included in delivery
-5 °C to +40 °C Cable connector and connecting cables for the data line
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 % Note
(IEC 721-3-3) no condensation
Data cable for RS-232 interface, max. length 10 m.
Mounting on the mainboard rear side Use converters for longer cables. Select the cable type
Weight 46 g (0.1 lbs) according to the cable length and the intended purpose.
One communication module can be installed into each
75 x 82 x 40 mm (WxLxD)
Dimensions control panel.
3 x 3.2 x 1.6 inch (WxLxD)

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

See panels
301-421_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 6
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 mod S spark test card Part no.: 909366


Function module for installation into a FMZ mod S
for testing spark detectors. Up to 4 spark detector groups can
be tested by means of the module and connected spark test
actuators without interruption of the monitoring process.

Product features Application


• 4 test outputs for connection of one test actuator each For testing installed spark detectors by means of a short light
• Function test of the spark detectors without interruption impulse which is emitted by a connected test actuator after
of the monitoring process triggering. The intensity of the light impulse is adjustable.
Practice-oriented test because integrates in the material
• Test either manual or at configured times with or without
flow during operation. Any undetected light impulse will be
release of the extinguishing
reported as a fault. The test can be started either manually
• Monitoring of the test actuators during the test or at configured daily times.
• Intensity of the test impulse adjustable in four steps
Included in delivery
Module ready for installation including fastening material
Technical specifications
Operating voltage 26.7 V DC Not included in delivery
Quiescent current (test outputs inactive) 10 mA DC Test actuators and installation material

Test outputs 4
Max. test current per outputs 1 A DC
Note
One module can be installed into each control panel.
-5 °C to +40 °C The test function can only be used in connection with ‚
Ambient temperature
(+23 °F to +104 °F)
spark extinguishing lines.
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Approvals / marking
Mounting on the mainboard rear side
See panels
Weight 100 g (0.2 lbs)
76 x 147 x 40 mm (WxLxH)
Dimensions
3 x 5.8 x 1.6 inch (WxLxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-421_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 7
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 mod S card Part no.: 909365


fire brigade periphery Function module for installation into an FMZ 5000 mod S
with all interfaces for connecting components to call and
inform the fire brigade, for the control panel operation by
the fire brigade as well as for the non-violent access to the
object via the key deposit.
Functions and connections comply with DIN 14675, DIN
14661, DIN 14662, and VdS 2350.

Product features Application


• One RS-422 interface for connecting a fire brigade For triggering and monitoring all fire brigade components,
control panel with serial data transfer such as:
• One RS-422 interface for connecting a fire brigade • One transmission device for fire and one for
display panel with serial data transfer fault messages

• Trigger interface for fire brigade key deposit box adapter • Connection of one serial fire brigade conrol panel
(FSD) with triggering of the door opening as well as and display panel
monitoring of door contact and tamper-proof line • One adapter for connecting a fire brigade key
• Trigger interface for the transmission device fire deposit box

• Trigger interface for the transmission device control


Included in delivery
Module ready for installation including fastening material

Technical specifications
Not included in delivery
Operating voltage 26.7 V DC Connecting lines and data cable
Quiescent current 30 mA DC
Data interfaces 2 RS-422 Note
Connection transmission device Data cable for RS-422 interface, max. length 1000 m.
Component interfases
fire, fault, FSD adapter Use converters for longer cables. Select the cable type
-5 °C to +40 °C according to the cable length and intended purpose.
Ambient temperature One fire brigade interface module can be installed in each
(+23 °F to +104 °F)
control panel.
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Mounting on the mainboard rear side Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 139 g (0.3 lbs) See panels


208 x 83 x 40 mm (WxLxH)
Dimensions
8.2 x 3.3 x 1.6 inch (WxLxH)
301-420_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 8
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Additional and alternative components of the FMZ 5000

mod 4
NT5100 3 A
mod 12 mod XL 21 mod XL 31 mod XL 40
NT5100 3 A

Front plate ZOC Front plate ZOC Front plate ZOC Front plate ZOC

1HE – 5HE 1HE – 5HE 1HE – 5HE 1HE – 5HE

CC red CC red CC red CC red CC red

ZOC ZOC ZOC ZOC ZOC

NT5000 5A NT5000 5A/15A NT5000 5A/15A NT5000 5A/15A

12 V/12 Ah -26 Ah NT5100 8A/12A NT5100 8A/12A NT5100 8A/12A

12 V/18 Ah - 45 Ah 12 V/26 Ah - 85 Ah 12 V/26 Ah -115 Ah

RT module FBCP 2001 Reflex


901969 RT Firealarm 908147 Spark detection /
Key locker 906262
instantaneous fire detection

Conventional Spark test


901773 903466

Modbus Modbus RS485


Loop AP XP / Loop AP XP red 904566 906853
906185 906186 Modbusmaster
SPS controls

Apollo Loop
Conventional
Relays
901595
Loop coupler Non-monitored
902954 controls

Voltage reversal More messages


904093
Control groups Audible alarm
901673 Ground fault
800096
Activations

OC/SC monitored PE
The contents of this publication are subject to modifications without notice. All rights reserved.

Voltage distribution
904093
SIO1 903466
SIO3 903467 24 V
Printer Control centers FBDP 2002 908148 GND
FBDP 2002 red 908149

Impulse valve reset Deluge valve


908324
MxNet
904877

MxNet
301-010_002 / AI01_2016en

Relay card 8 TQ Relay card 8


800843 802587
Webmodule N 914365
Webmodule S 914366 Remote Display
Internet

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 9
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 complete OU

Fire alarm panel FMZ 5000 mod 4 L GW Part no.: 908593


Compact fire alarm panel of the fire alarm panel range
FMZ 5000. Equipped and ready for fire detection in
conventional technology for a maximum of 128 detectors,
monitoring and control of a single-zone extinguishing system.
Signal indication through large LC display and LEDs,
menu-guided operation using configurable function keys.

Application Product features


For use as fire alarm and extinguishing control panel in • Expansion of the fire alarm panel is designed for
single-zone extinguishing systems. controlling a single-zone extinguishing system
• 4 conventional detector lines, 4 control groups,
8 relays with 1 potential-free changeover contact each
Technical specifications • Collective signal LED and individual LED pairs,
red/yellow, for status indications
Mains voltage 115 V / 230 V AC ±15%
• Large LC display, fully graphical with menu-driven
Mains frequency 50 Hz - 60 Hz operation
Operating voltage 21 V - 27,2 V DC • Emergency power batteries 12 Ah
Power supply unit 24 V DC / 3 A • The fire alarm is completely preconfigured and ready
Quiescent current approx. 225 mA for operation

Battery capacity 2 x 12 V / 12 Ah
External control voltage 21 V - 27.2 V DC
Included in delivery
Fire alarm panel with front display and operating plate,
Contact load 1 A / 30 V DC, 0.5 A / 125 V AC central card and power supply unit, and one conventional
Max. switching capacity 30 W /62.5 VA detector module, control group module and relay module
-5°C to + 40°C each as well as a zone operating panel card. 2 x 12 Ah
Ambient temperature batteries.
(+23 °F to +104 °F)
Wired ready for operation and preconfigured.
Relative humidity max. 95 %
Operating instructions, terminal assignment, operator’s log,
(IEC 721-3-3) no condensation
installation manual, drilling template.
Enclosure Sheet steel 4U
475 x 340 x 200 mm (WxHxD)
18.7 x 13.4 x 7.9 inch (WxHxD)
Approvals / marking
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

Length mounting rail 1 x 213 mm G 204124 0786-CPD-20843


(8.4 inch) G 205019 0786-CPD-20222
IP rating (EN 60529) IP 54
EN 54-2 A1: 2006
Specification according to EN 54-4 A2: 2006
EN 12094-1: 2003
Colour RAL 7035
approx. 20 kg (44.1 lbs)
Weight
with batteries and modules
Mounting Wall-mounted installation
301-640_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 10
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 4 Part no.: 908551


NT5100 3A Smallest base unit in the modular fire alarm panel
range FMZ 5000. The wall enclosure is also suitable for
flush-mounted wall installation or for desk mounting.
For connecting analogue addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces. Signal indication through
large LC display and LEDs, menu-guided operation using
configurable function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in small-scale projects. for all project tasks
Also for controlling multi-zone extinguishing systems • Can also be expanded for control of multi-zone
through redundant hardware. extinguishing systems with redundant hardware
• Up to 4 detector loops with 126 detectors each,
16 conventional detector lines for 32 detectors of
any design each
Technical specifications
• Up to 16 control groups and 32 relays
Mains voltage 115 V / 230 V AC ±15%
• 14 collective signal LEDs, some in two colours, 16 LED
Mains frequency 50 Hz - 60 Hz pairs, red/yellow, for individual signal indications
Operating voltage 21 V - 27,2 V DC • Large LC display, fully graphical with menu-guided
Power supply unit 24 V DC / 3 A operation
Quiescent current approx. 120 mA DC
• Can be loop networked up to 32 units in total
• The enclosure has space for emergency power batteries
Battery 2 x 12 V / 12 Ah internal
up to 12 Ah
External control voltage 21 V - 27,2 V DC
• All settings are carried out via a fully graphical interface
-5°C to +40°C on a PC with the MxSysCon configuration program
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Included in delivery
Fire alarm panel with front display, operating plate, central
Enclosure Sheet steel 4U card and power supply unit.
475 x 340 x 200 mm (WxHxD) Wired ready for the insertion of any modules.
18.7 x 13.4 x 7.9 inch (WxHxD) No additional wiring in the fire alarm panel required.
Length of mounting rail Operating instructions, operator’s log, installation manual,
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 1 x 213 mm (8.4 inch) drilling template.


usable mounting rail length for
function modules 1 x 160 mm Not included in delivery
(6.3 inch) Modules, zone operating panel cards, batteries, report
IP rating (EN 60529) IP 54 printer, installation material
EN 54-2 A1:2006
Specification according to EN 54-4 A2:2006 Note
EN 12094-1:2003 Order batteries separate.
Colour RAL 7035 Alternative batteries must be selected according to the table
at the end of the chapter.
approx. 15 kg (33.1 lbs)
Weight
without modules
301-410_002 / AI00_2015en

Mounting Wall-mounted installation Approvals / marking


G 204124 0786-CPD-20843
G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 11
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 4 Part no.: 905231


Smallest base unit in the modular fire alarm panel
range FMZ 5000. The wall enclosure is also suitable for
flush-mounted wall installation or for desk mounting.
For connecting analogue addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using configurable function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in small-scale projects. for all project tasks
Also for controlling multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 4 detector loops with 126 detectors each,
16 conventional detector lines for 32 detectors of any
Technical specifications design each
• Up to 16 control groups and 32 relays
Mains voltage 115 V / 230 V AC -15%, +10%
• 14 collective signal LEDs, some in two colours, 16 LED
Mains frequency 50 Hz - 60 Hz
pairs, red/yellow, for individual signal indications
Operating voltage 19.5 V - 29 V DC • Large LC display, fully graphical with menu-guided
Power supply unit 24 V DC / 1.5 A operation
Quiescent current approx. 120 mA DC • Can be loop networked up to 32 units in total
Battery 2 x 12 V / 12 Ah internal • The enclosure has space for emergency power batteries
up to 12 Ah
External control voltage 21 V - 29.6 V DC
• All settings are carried out via a full graphical interface
-5°C to +40°C
Ambient temperature
(+23 °F to +104 °F)
on a PC with the MxSysCon configuration program

Relative humidity max. 95 %


(IEC 721-3-3) no condensation Included in delivery
Enclosure Sheet steel 4U Fire alarm panel with front display, operating plate,
central card and power supply unit.
475 x 340 x 200 mm (WxHxD)
Wired ready for the insertion of any modules.
18.7 x 13.4 x 7.9 inch (WxHxD)
No additional wiring in the fire alarm panel required.
Length of mounting rail
Operating instructions, operator’s log, installation manual,
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 1 x 213 mm (8.4 inch)


drilling template.
usable mounting rail length for
function modules 1 x 160 mm
(6.3 inch) Not included in delivery
IP rating (EN 60529) IP 54 Modules, zone operating panel cards, batteries, report
printer, installation material
Colour RAL 7035
approx. 15 kg (33.1 lbs)
Weight Note
without modules
Mounting Wall-mounted installation Order batteries separate.

Approvals / marking
301-410_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 12
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 12 Part no.: 903177


Medium-size base unit from the fire alarm panel
range FMZ 5000. Elegant 19” wall enclosure with front
door in stainless steel coloured frame. For connecting
analogue addressable detectors and conventional detectors
in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in medium-scale projects. for all project tasks
Also for controlling of multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
176 conventional detector lines for 32 detectors of
any design each
Technical specifications
• Up to 176 control groups and 176 relays
Mains voltage 115 V / 230 V AC -15%, +10%
• 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz max. 192 LED pairs, red/yellow, for individual signal
Operating voltage 19.5 V - 29 V DC indications
Power supply unit 24 V DC / 2.7 A • Large LC display, full graphical with menu-guided
operation
Quiescent current approx. 120 mA DC
• Can be loop networked up to 32 units
Battery 2 x 12 V / 26 Ah internal
• The enclosure has space for emergency power batteries
External control voltage 21 V - 29.6 V DC up to 18 Ah
-5°C to +40°C • All settings are defined via a fully graphical interface on
Ambient temperature
(+23 °F to +104 °F)
a PC with the MxSysCon configuration program
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Included in delivery
Enclosure Sheet steel 12U Fire alarm panel with front display, operating plates,
600 x 604 x 225 mm (WxHxD) central card and power supply unit.
23.6 x 23.8 x 8.9 inch (WxHxD) Wired ready for the insertion of any modules.
Length of mounting rail No additional wiring in the fire alarm panel is required.
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 3 x 325 mm (12.8 inch) Operating instructions, operator’s log, installation manual,
usable mounting rail length for drilling template.
function modules 3 x 270 mm
(10.6 inch) Not included in delivery
IP rating (EN 60529) IP 54 Cable set FMZ 5000 module 904101
Colour RAL 7035 Modules, zone operating panel card, front plate BBF, dummy
plates, batteries, report printer, installation material.
approx. 26 kg (57.3 lbs)
Weight
without modules
Mounting Wall-mounted installation
Note
Order batteries separate.
301-410_004 / AI00_2015en

Approvals / marking

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 13
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 12 Part no.: 908563


NT5100 3A Medium-size base unit from the fire alarm panel range
FMZ 5000. Elegant 19” wall enclosure with front door
in stainless steel coloured frame. For connecting analogue
addressable detectors and conventional detectors in
standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be
detection and extinguishing control in medium-scale projects. used for all project tasks
Also for controlling of multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
176 conventional detector lines for 32 detectors of
any design each
Technical specifications
• Up to 176 control groups and 176 relays
Mains voltage 115 V / 230 V AC ±15%
• 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz max. 192 LED pairs, red/yellow, for signal indications
Operating voltage 21 V - 27,2 V DC • Large LC display, fully graphical with menu-guided
Power supply unit 24 V DC / 3 A operation
• Can be loop networked up to 32 units
Quiescent current approx. 120 mA DC
• The enclosure has space for emergency power batteries
Battery 2 x 12 V / 26 Ah internal
up to 18 Ah
External control voltage 21 V - 27,2 V DC • All settings are defined via a fully graphical interface on a
-5°C to +40°C PC with the MxSysCon configuration program
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 % Included in delivery
(IEC 721-3-3) no condensation Fire alarm panel with front display, operating plate,
control card and power supply unit. Wired ready for insertion
Enclosure Sheet steel 12U
of any modules. No additional wiring in the fire alarm panel
600 x 604 x 225 mm (WxHxD) is required. Operating instructions, operator’s log, installation
23.6 x 23.8 x 8.9 inch (WxHxD) manual, drilling template.
Length of mounting rail Additional expanded models upon request.
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 3 x 325 mm (12.8 inch)


usable mounting rail length for Not included in delivery
function modules 3 x 270 mm Cableset FMZ 5000 module 904101
(10.6 inch) Modules, zone operating panel cards, front plate BBF,
IP rating (EN 60529) IP 54 dummy plates, batteries, report printer, installation material.
EN 54-2 A1:2006
Specification according to EN 54-4 A2:2006 Note
EN 12094-1:2003 Alternative power supply units and batteries must be selected
Colour RAL 7035
according to the table at the end of the chapter.
Order batteries separate.
Approx. 26 kg (57.3 lbs)
Weight
without modules
Approvals / marking
301-410_005 / AI00_2015en

Mounting Wall-mounted installation G 204124 0786-CPD-20843


G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 14
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 12 NEW Part no.: 920643
NT5000 5A Medium-size base unit from the fire alarm panel range
FMZ 5000. Elegant 19” wall enclosure with front door
in stainless steel coloured frame. For connecting analogue
addressable detectors and conventional detectors in
standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be
detection and extinguishing control in medium-scale projects. used for all project tasks
Also for controlling of multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
176 conventional detector lines for 32 detectors of
any design each
Technical specifications
• Up to 176 control groups and 176 relays
Mains voltage 115 V / 230 V AC -15%, +10% • 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz max. 192 LED pairs, red/yellow, for signal indications
Operating voltage 21 V - 29 V DC • Large LC display, fully graphical with menu-guided
operation
Power supply unit 24 V DC / 5 A
• Can be loop networked up to 32 units
Quiescent current approx. 120 mA DC
• The enclosure has space for emergency power batteries
Battery 2 x 12 V / 18 Ah internal up to 26 Ah
External control voltage 21 V - 29 V DC • All settings are defined via a fully graphical interface on a
-5°C to +40°C PC with the MxSysCon configuration program
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 % Included in delivery
(IEC 721-3-3) no condensation Fire alarm panel with front display, operating plate,
Enclosure Sheet steel 12U control card and power supply unit. Wired ready for insertion
600 x 604 x 225 mm (WxHxD)
of any modules. No additional wiring in the fire alarm panel
23.6 x 23.8 x 8.9 inch (WxHxD) is required. Operating instructions, operator’s log, installation
manual, drilling template.
Length of mounting rail
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 3 x 325 mm (12.8 inch) Additional expanded models upon request.


usable mounting rail length for
function modules 2 x 270 mm Not included in delivery
(10.6 inch), 1 x x170 mm (6.7 inch) Cableset FMZ 5000 module 904101
IP rating (EN 60529) IP 54 Modules, zone operating panel cards, front plate BBF,
EN 54-2 A1:2006
dummy plates, batteries, report printer, installation material.
Specification according to EN 54-4 A2:2006
EN 12094-1:2003
Note
Colour RAL 7035 Alternative power supply units and batteries must be selected
Approx. 26 kg (57.3 lbs) according to the table at the end of the chapter.
Weight Order batteries separate.
without modules
301-410_006 / AI01_2016en

Mounting Wall-mounted installation


Approvals / marking
G 204124 0786-CPD-20843
G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 15
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 12 Part no.: 910889


BMA AP Medium-size base unit of the fire alarm panel range
FMZ 5000. Elegant 19“ wall enclosure with front door
in stainless steel coloured frame. Equipped for fire
detection, monitoring and control of fired detection
systems in a maximum of 512 devices in analogue
addressable technology and a maximum of 128 devices
in conventional technology.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use as fire detection panel whith optional extension • Connection for remote transmission unit and fire brigade
possibilities. control panel (FBF)
• Expansion of the fire alarm panel is designed for
controlling of one fire detection system
Technical specifications • 4 detector loops, 4 conventional detector lines,
4 control groups, 8 relays with 1 potential-free
Mains voltage 115 V / 230 V AC -15%, +10%
changeover contact each
Mains frequency 50 Hz - 60 Hz
• Collective signal LED and 32 individual LED pairs,
Operating voltage 21 V - 29 V DC red/yellow, for status indications
Power supply unit 24 V DC / 5 A • Large LC display, fully graphical with menu-guided
Quiescent current approx. 340 mA DC operation

Battery 2 x 12 V / 26 Ah internal
• Emergency power batteries 26 Ah

External control voltage 21 V - 29 V DC


-5 °C to +40 °C Included in delivery
Ambient temperature
(+23 °F to +104 °F) Fire alarm panel with front display and operating plate,
Relative humidity max. 95 % 1 Central card
(IEC 721-3-3) no condensation 1 Power supply unit 5 A
2 Loop module
Enclosure Sheet steel 12U
1 Remote transmission unit module
600 x 604 x 225 mm (WxHxD) 1 Conventional detector module
23.6 x 23.8 x 89 inch (WxHxD) 1 Control group module
Dimensions
Length of mounting rail 1 Relay module
3 x 325 mm (12.8 inch) 1 Power distribution module
IP rating (EN 60529) IP 54 2 Zone operating panel cards
The contents of this publication are subject to modifications without notice. All rights reserved.

2 26 Ah batteries
EN 54-2 A1:2006
Specification according to EN 54-4 A2:2006 Wired ready for operation and preconfigured.
EN 12094-1:2003 Operating instructions, terminal assignment, operator‘s log,
Colour RAL 7035 installation manual, drilling stencil
approx. 51 kg (112.4 lbs)
Weight
with batteries and modules Approvals / marking
Mounting Wall-mounted installation G 204124 0786-CPD-20843
G 205019 0786-CPD-20222
301-410_007 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 16
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod 12 Part no.: 910890


LSZ AP Medium-size base unit of the fire alarm panel range
FMZ 5000. Elegant 19“ wall enclouse with front door in
stainless steel coloured frame. Equipped and ready for
fire detection, monitoring and control for one single-zone
extinguishing system in a maximum of 256 devices in
analogue addressable technology and a maximum of 256
devices in conventional technology. Signal indication through
large LC display and LEDs, menu-guided operation using
function keys.

Application Product features


For use as extinguishing control panel in single-zone • Expansion of the fire alarm panel is designed for
extinguishing systems whith optional extension possibilities. controlling of one single-zone extinguishing system
• 2 detector loops, 8 conventional detector lines,
4 control groups, 8 relays with 1 potential-free
changeover contact each
Technical specifications
• Collective signal LED and 16 individual LED pairs,
Mains voltage 115 V / 230 V AC -15%, +10% red/yellow, for status indications
Mains frequency 50 Hz - 60 Hz • Large LC display, full graphical with menu-guided
Operating voltage 21 V - 29 V DC operation
Power supply unit 24 V DC / 5 A • Emergency power batteries 26 Ah
Quiescent current approx. 330 mA DC • The fire alarm panel is preconfigured and just needs
individual settings
Battery 2 x 12 V / 26 Ah internal,
• 2 mounting rails with effective useable length of 273 mm
External control voltage 21 V - 29 V DC
(10.8 inch) and 1 with a lenght of 173 mm (6.8 inch)
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 % Included in delivery
(IEC 721-3-3) no condensation Fire alarm panel with front display and operating plate,
1 Central card
Enclosure Sheet steel 12U
1 Power supply unit 5 A
600 x 604 x 225 mm (WxHxD) 1 Loop module
23.6 x 23.8 x 89 inch (WxHxD) 2 Conventional detector module
Dimensions
Length of mounting rail 1 Control group module
3 x 325 mm (12.8 inch) 1 Relay module
IP rating (EN 60529) IP 54 1 Power distribution modul
The contents of this publication are subject to modifications without notice. All rights reserved.

EN 54-2 A1:2006 2 Zone operating panel cards


Specification according to EN 54-4 A2:2006 2 26 Ah batteries
EN 12094-1:2003
Wired ready for operation and preconfigured.
Colour RAL 7035 Operating instructions, terminal assignment, operator‘s log,
Weight approx. 51 kg (112.4 lbs) installation manual, drilling stencil
Mounting Wall-mounted installation
Approvals / marking
G 204124 0786-CPD-20843
G 205019 0786-CPD-20222
301-410_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 17
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod XL 21U Part no.: 905454
Base unit from the fire alarm panel range FMZ 5000
as 19” version in a wall enclosure with a height of 21U.
For connecting analogue addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in medium scale projects. for all project tasks
Also control of multi-zone extinguishing systems through • Can also be expanded for controlling multi-zone
redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
up to 176 conventional detector lines for 32 detectors
of any design each
Technical specifications
• Up to 176 control groups and 176 relays
Mains voltage 115 V / 230 V AC -15%, +10%
• 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz max. 272 LED pairs, red/yellow, for signal indications
Operating voltage 21 V - 29 V DC • Large LC display, full graphical with menu-guided
Power supply unit see table 1 - 20 operation
Quiescent current approx. 120 mA DC • Can be loop networked up to 32 units
Battery see table 1 - 20 • All settings are defined via a fully graphical interface on
a PC with the MxSysCon configuration program.
External control voltage 21 V - 29 V DC

Ambient temperature
-5°C to +40°C Included in delivery
(+23 °F to +104 °F)
Fire alarm panel in 21U wall enclosure fitted with front
Relative humidity max. 95 % display and operating plate, central card.
(IEC 721-3-3) no condensation Wired ready for the insertion of any modules.
Enclosure Sheet steel 21U No additional wiring within the fire alarm panel required for
600 x 1012 x 373 mm (WxHxD) expansion.
23.6 x 39.8 x 14.7 inch (WxHxD) Operating instructions, operator’s log, mounting manual.
Length of mounting rail
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 4 x 325 mm (12.8 inch) Not included in delivery


usable mounting rail length for Cable set FMZ 5000 mod XL module 905113
function modules 2 x 270 mm Modules, zone operating panel card, power supply unit,
(10.6 inch), 1 x 170 mm (6.7 inch) front plate BBF, dummy plates, batteries, report printer,
IP rating (EN 60529) IP 55 installation material
EN 54-2 A1:2006
Specification according to EN 54-4 A2:2006 Note
EN 12094-1:2003 Control panel without power supply unit.
Colour RAL 7035 The power supply unit and the batteries must be selected
according to the table at the end of the chapter.
approx. 70 kg (154.3 lbs)
Weight
without modules
301-410_009 / AI00_2015en

Mounting Wall-mounted installation


Approvals / marking
G 204124 0786-CPD-20843
G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 18
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod XL 31U Part no.: 905481
Base unit of the fire alarm panel range FMZ 5000 as 19”
version in a free-standing enclosure with a height of 31U
with variable depth, width and base dimensions.
For connecting analogue addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and
control stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in projects up to very for all project tasks
large size. Also control of multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
up to 256 conventional detector lines for 32 detectors
Technical specifications of any design each
• Up to 256 control groups and 512 relays
Mains voltage 115 V / 230 V AC -15%, +10%
• 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz
max. 432 LED pairs, red/yellow, for signal indications
Operating voltage 21 V - 29 V DC
• Large LC display, full graphical with menu-guided
Power supply unit see table 1- 20 operation
Quiescent current approx. 120 mA DC • Can be loop networked with up to 32 units
Battery see table 1- 20 • All settings are defined via a fully graphical interface on a
External control voltage 21 V - 29 V DC PC with the MxSysCon configuration program

-5°C to +40°C
Ambient temperature
(+23 °F to +104 °F) Included in delivery
Fire alarm panel in free-standing enclosure fitted with front
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
display and operating plate, central card.
Wired ready for the insertion of any modules.
Enclosure Sheet steel 31U No additional wiring within the fire alarm panel required
800 x 1600 x 600 mm (WxHxD) for expansion.
(31.5 x 63 x 23.6 inch) (WxHxD) Operating instructions, operator’s log, mounting manual.
(H without base)
The contents of this publication are subject to modifications without notice. All rights reserved.

Length of mounting rail Not included in delivery


Dimensions
5 x 475 mm (18.7 inch)
Cable gland 800 mm IP rating IP 55 908504
usable mounting rail length for
Cable set FMZ 5000 mod XL module 905113
function modules 3 x 425 mm
(16.7 inch), 1 x 325 mm (12.8 inch)
Modules, zone operating panels, front panel BBF, dummy
plates, power supply unit, batteries, report printer, installation
IP 53 material.
IP rating (EN 60529)
with separate cable gland IP 55
EN 54-2 A1:2006 Note
Specification according to EN 54-4 A2:2006
EN 12094-1:2003 Control panel without power supply unit.
The power supply unit and the batteries must be selected
Colour RAL 7035 according to the table at the end of the chapter.
301-410_010 / AI00_2015en

Weight
approx. 160 kg (352.7 lbs) Approvals / marking
without modules
G 204124 0786-CPD-20843
Mounting Stand-alone cabinet
G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 19
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Fire alarm panel FMZ 5000 mod XL 40U Part no.: 905041
Base unit from the fire alarm panel range FMZ 5000
as 19” version in a free-standing cabinet with a height of
40U with variable depth, width and base dimensions and
various design variants.
For connecting analogue addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for fire and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.

Application Product features


For use for sole fire detection control or combined fire • Free selection of functional modules to be used
detection and extinguishing control in projects up to very for all project tasks
large size. Also control of multi-zone extinguishing systems • Can also be expanded for controlling multi-zone
through redundant hardware. extinguishing systems with redundant modules
• Up to 28 detector loops with 126 detectors each,
up to 256 conventional detector lines for 32 detectors
Technical specifications of any design each
• Up to 256 control groups and 256 relays
Mains voltage 115 V / 230 V AC -15%, +10%
• 14 collective signal LEDs, some in two colours,
Mains frequency 50 Hz - 60 Hz
max. 432 LED pairs, red/yellow, for signal indications
Operating voltage 21 V - 29 V DC • Large LC display, full graphical with menu-guided
Power supply unit see table 1 - 20 operation
Quiescent current approx. 120 mA DC • Can be loop networked with up to 32 units
Battery see table 1 - 20 • All settings are defined via a full graphical interface on a
PC with the MxSysCon configuration program
External control voltage 21 V - 29 V DC
-5°C to +40°C
Ambient temperature
(+23 °F to +104 °F) Included in delivery
Fire alarm panel in free-standing enclosure fitted with front
Relative humidity max. 95 %
display and operating plate, control card.
(IEC 721-3-3) no condensation
Wired ready for insertion of any modules.
Enclosure Sheet steel 40U No additional wiring within the fire alarm panel required for
800 x 2000 x 600 mm (WxHxD) expansion.
(31.5 x 78.7 x 23.6 inch) (WxHxD) Operating instructions, operator’s log, mounting manual.
(H without base)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions
Length of mounting rail Not included in delivery
7 x 475 mm (18.7 inch)
Cable gland 800 mm IP rating IP 55 908504
usable mounting rail length for Cable set FMZ 5000 mod XL module 905113
function modules 5 x 425 mm
Modules, zone operating panels, dummy front plates, power
(16.7 inch), 1 x 325 mm (12.8 inch)
supply unit, batteries, report printer, installation material
IP 53
IP rating (EN 60529)
with separate cable gland IP 55
Note
EN 54-2 A1:2006
Control panel without power supply unit.
Specification according to EN 54-4 A2:2006
EN 12094-1:2003 The power supply unit and the batteries must be selected
according to the table at the end of the chapter.
Colour RAL 7035
Approvals / marking
301-410_011 / AI00_2015en

approx. 190 kg (418.9)


Weight
without modules
G 204124 0786-CPD-20843
Mounting Stand-alone cabinet G 205019 0786-CPD-20222

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 20
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 base unit

Overview of alternative power supply unit and maximum battery capacity per control panel

FMZ 5000 mod XL


VdS FM FMZ 5000 mod 4 FMZ 5000 mod 12
21 HE 31 HE 40 HE

NT5000 5 A
X X --- 26 Ah 45 Ah * 45 Ah * 45 Ah *
(Part no. 901037)

NT5000 15 A 115 Ah * and 115 Ah * and


X X --- 26 Ah 65 Ah
(Part no. 901038) 130 Ah ** 130 Ah **

NT5100 3 A
X --- 12 Ah 26 Ah * --- --- ---
(Part no. 908452)

NT5100 8 A
X --- --- 26 Ah 65 Ah 85 Ah * 85 Ah *
(Part no. 908453)

NT5100 12 A
X --- --- 26 Ah 65 Ah 115 Ah * 115 Ah *
(Part no. 908454)

* Battery in combination with power supply unit without VdS approval


** Based on two power supply units or parallel connection 4 x 65 Ah
For batteries from 2 x 85 Ah or 4 x 65 Ah, a heavy-duty pivot frame must be used

Overview of alternative batteries for power supply units

NT5000 5 A VdS/ NT5000 15 A VdS/ NT5100 3 A VdS/ NT5100 8 A VdS/ NT5100 12 A VdS/
(Part no. EN (Part no. EN (Part no. EN (Part no. EN (Part no. EN
901037) 54-4 901038) 54-4 908452) 54-4 908453) 54-4 908454) 54-4

Battery 2,2 Ah
--- --- --- --- --- --- --- --- --- ---
(Part no. 236023)

Battery 7,2 Ah
X X --- --- X X --- --- --- ---
(Part no. 902941)

Battery 12 Ah
X X --- --- X X --- --- --- ---
(Part no. 761677)

Battery 18 Ah
X X X X X X X X X X
(Part no. 756859)
The contents of this publication are subject to modifications without notice. All rights reserved.

Battery 26 Ah
X X X X X --- X X X X
(Part no. 132721)

Battery 45 Ah
X --- X X --- --- X X X X
(Part no. 832386)

Battery 65 Ah
--- --- X X --- --- X X X X
(Part no. 794921)

Battery 85 Ah
--- --- X X --- --- X --- X ---
(Part no. 801758)

Battery 115 Ah
--- --- X --- --- --- --- --- X ---
301-410_020 / AI00_2015en

(Part no. 800775)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 21
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 Loop AP XP module Part no.: 906185


Functional module for use in all design variants of the
fire alarm system FMZ 5000. Includes 2 detector loops
for connection of up to 126 devices each. Instead of a
loop, 2 branches can be connected to the module.
Any number of T branches can be connected to each loop.
The loop devices can be fire detectors, input/output
modules, control modules for sounders and loop couplers
for the operation of conventional detectors in the loop.
For use in potentially explosive atmospheres, IS-detectors
can be connected to the loop via protocol interface and
safety barriers.

Product features Application


• For the interface connection of analogue addressable For fire detection with detectors using loop technology.
detectors and modules with Loop AP protocol System monitoring by connecting switches to addressable
• The high loop current enables the operation of input modules. Control of fire protection devices via dry
multiple modules, sounders, flash lights and detectors contacts or monitored via output modules.
in a single loop Interface connection of monitored zone horns via a
sounder module. For the operation of conventional
• All settings of the module, the detectors and the detectors in the loop, these are connected to a loop coupler.
detector zones are configured using the MxSysCon The module is inserted into the panel with separate
configuration program powersupply by power distribution module. The power
• No further adjustment is required supply and system communication are connected via
plug-in connections on the module enclosure.
Up to 14 modules can be used in one fire alarm panel.

Technical specifications
Included in delivery
Operating voltage (module) 18 V - 30 V DC
Module completely assembled and ready for installation in
Quiescent current the fire alarm panel
max. 52 mA DC
(module-bus)
Supply current max. 1.440 mA DC
Not included in delivery
Loop current max. 400 mA DC
4 Socket terminal strips FKCT 2.5/3-ST 901564
Loop voltage 27 V DC Power distribution module  904093
Number of loops 2
Number of detectors per loop 126 Application in potentially explosive
Max. terminal cross-section 2.5 mm2 (AWG 13) atmospheres
-5 °C to +40 °C Only the following barriers are permitted:
The contents of this publication are subject to modifications without notice. All rights reserved.

Ambient temperature Safety barriere IS addressable 24 V  901324


(+23 °F to +104 °F)
Loop AP protocol interface 901322
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20 Note
Enclosure Polyamide PA6.6, green If the loops of one loop module are used for fire detection
or controlling several extinguishing zones, the loop module
Installation position vertical
AP XP redundant, Part no. 906186 must be used.
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 220 g (0.5 lbs)
Approvals / marking
See panels
35 x 99 x 114.5 mm (WxHxD)
301-420_004 / AI00_2015en

Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)
Total cable length max. 2000 m (6562 ft) per loop

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 22
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 Loop AP XP redundant module Part no.: 906186


Functional module for use in all design variants of the
fire alarm system FMZ 5000. The loop module includes
two redundant processors for the operation in multi-zone
extinguishing systems in accordance with standards.
Includes 2 detector loops for connection of up to 126 devices
each. Instead of a loop, 2 branches can be connected to the
module. Any number of T branches can be connected to each
loop. The loop devices can be fire detectors, input/output
modules, control modules for sounders and loop couplers
for the operation of conventional detectors in the loop.
For use in potentially explosive atmospheres, IS-detectors
can be connected to the loop via protocol interface and
safety barriers.

Product features Application


• Includes redundant processors for the control For fire detection in several zones of multi-zone
of the module and the loops extinguishing systems by means of detectors using loop
technology. System monitoring by connecting switches
• For the interface connection of analogue addressable
to addressable input modules. Control of fire protection
detectors and modules with Loop AP protocol
devices via dry contacts or monitored via output modules.
• The high loop current enable the operation of Interface connection of monitored zone horns via a sounder
multiple modules, sounders, flash lights and detectors module. For the operation of conventional detectors in the
in a single loop loop, these are connected to a loop coupler.
• All settings of the module, the detectors and detector The module is inserted into the panel with separate power-
zones are carried out with the MxSysCon configuration supply by power distribution module. The power supply
program and system communication are connected via plug-in
• No further adjustment is required connections on the module enclosure.
Up to 14 modules can be used in one fire alarm panel.

Included in delivery
Technical specifications Module completely assembled and ready for installation in
Operating voltage (module) 18 V - 30 V DC the fire alarm panel
Quiescent current
max. 85 mA DC
(module-bus) Not included in delivery
Supply current max. 1440 mA DC 4 Socket terminal strips FKCT 2.5/3-ST 901564
Loop current max. 400 mA DC Power distribution module 904093
Loop voltage 27 V DC
Number of loops 2 Application in potentially explosive
Number of detectors per loop 126
atmospheres
The contents of this publication are subject to modifications without notice. All rights reserved.

2
Only the following barriers are permitted:
Max. terminal cross-section 2.5 mm (AWG 13)
Safety barriere IS addressable 24 V  901324
-5 °C to +40 °C Loop AP protocol interface 901322
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Note
For fire detection in single-zone extinguishing systems,
IP rating (EN 60529) IP 20
the module loop AP XP, Part no. 906185 can be used.
Enclosure Polyamide PA6.6, green
Installation position vertical Approvals / marking
Mounting
Mounting rail 35 DIN 46277, See panels
top hat profile
301-420_005 / AI00.2015en

Weight 220 g (0.5 lbs)


35 x 99 x 114.5 mm (WxHxD)
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)
Total cable length max. 2000 m (6562 ft) per loop

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 23
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 conventional detector module Part no.: 901773


Functional module for use in all design variants of the
fire alarm system FMZ 5000. Includes 4 quiescent
current monitored detector lines for the connection of
conventional detectors in accordance with the applicable
national regulations. A detector event is reported via a
current increase. Each line has 4 adjustable thresholds:
quiescent current, wire breakage, short circuit, event.
The voltage of each line can be adjusted separately in the
range of 9 V to 20 V.
All conventional detectors in the Minimax detector range can
be used with this operating voltage range, as well as devices
from other manufactures.

Product features Application


• Large range of detector types available for in For connection of any type of conventional detectors or
virtue of the wide adjustment range of the line manual call points in standard or industrial design.
voltages and current thresholds System monitoring takes place by connecting appropriate
• All detectors can be operated with two-detector monitoring switches with dry contacts.
dependency and all zones with two-zone dependency The module is inserted into the panel without additional
wiring. The power supply and system communication are
• All settings are carried out with the MxSysCon connected via plug-in connections on the module enclosure.
configuration program Up to 64 modules can be used in one fire alarm panel.
• No further adjustment is required
Included in delivery
Module completely assembled and ready for installation
Technical specifications in the panel
Operating voltage 19 V - 29 V DC
Quiescent current 2 mA - 50 mA DC
Not included in delivery
4 Socket terminal strips FKCT 2.5/3-ST 901564
Line voltage 9 V - 20 V DC
Alarm current 5 mA - 80 mA DC
Note
Terminating resistor 1.8 kW
Each module may be operated only with Minimax detectors
Number of detector groups 4, quiescent current controlled or with detector of other manufactures. Manual call points
Number of detectors per line 32 pieces (VdS) and monitoringcontests can be freely mixed with all other
detector types.
Max. terminal cross-section 2.5 mm2 (AWG 13)
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F) Approvals / marking
See panels
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 95 %


(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 120 g (0.26 lbs)
17.5 x 99 x 114.5 mm (WxHxD)
Dimensions
0.7 x 3.9 x 4.5 inch (WxHxD)
301-420_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 24
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 control group module Part no.: 901673


Functional module for use in all design variants of the fire
alarm system FMZ 5000.
Includes 4 control lines for the monitoring and control of fire
protection devices. The line to the devices is monitored for
wire breakage and short circuits.
The connected fire protection devices are also monitored to
verify that they are present and in proper condition.

Product features Application


• Control groups can be time-controlled with delays, For monitoring and control of e.g. valves, solenoids or horns
pulse controlled or continuously controlled in extinguishing systems or other fire protection devices.
• All settings are carried out with the MxSysCon The module is inserted into the panel with separate
configuration program. powersupply by power distribution module. The power
supply and system communication are connected via
• No furher adjustment work is required plug-in connections on the module enclosure.
Up to 64 modules can be used in one fire alarm panel.

Technical specifications Included in delivery


Operating voltage 21 V - 29 V DC Module completely assembled and ready for installation in
the fire alarm panel
Quiescent current 25 mA DC
Number of control groups 4, quiescent current monitored
Not included in delivery
External control groups 21 V - 29 V DC
4 Socket terminal strips FKCT 2.5/3-ST 901564
Output current 1 A, continuous load
Time-controlled, continuous,
Control
pulse, inverted
Spare parts
Fuse 2 A / 125 V 784352
Max. terminal cross-section 2.5 mm2 (AWG 13)
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F) Note
If the module is used to sounders or extinguishing devices
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
in multi-zone extinguishing systems, a separate control
group module must be used for each extinguishing zone.
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking
Installation position vertical See panels
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 100 g (0.2 lbs)
17.5 x 99 x 114.5 mm (WxHxD)
Dimensions
0.7 x 3.9 x 4.5 inch (WxHxD)
301-420_007 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 25
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 8 relay module Part no.: 901595


Functional module for use in all design variants of the fire
alarm system FMZ 5000.
The module has 8 relays, each with a dry contact.
An activated relay is indicated by a red status LED.
A separate relay card with up to 8 additional relays can be
connected via a plug connector strip. Control happens via
open collector outputs parallel to the relays in the module.
This allows relays with higher switching voltages or currents
to be used.

Product features Application


• Relays are time-controlled with delays, For the dry-contact control of e.g. fire protection devices,
pulse control or continuous control graphic annunciators, ventilation system shutdown or for
• All settings are carried out with the MxSysCon general signal transfer.
configuration program The module is inserted into the panel without additional
wiring. The power supply and system communication are
• No further adjustment work is required connected via plug-in connections on the module enclosure.
Up to 64 modules can be used in one fire alarm panel.

Technical specifications Included in delivery


Operating voltage 19 V - 29 V DC Module completely assembled and ready for installation in
the fire alarm panel
Quiescent current 10 mA DC
Current per relay 10 mA DC
Not included in delivery
Number of relays 8 TQ
8 socket terminal strips FKCT 2.5/3-ST 901564
Contacts per relay 1 changeover, dry Relay card 8 TQ 800843
Contact load 1 A / 30 V DC, 0.5 A / 125 V AC Relay card 8  802587
Max. switching capacity 30 W / 62.5 VA
Time-controlled, continuous, Note
Control
pulse, inverted The contacts of the relays in the module are not suitable for
Max. terminal cross-section 2.5 mm2 (AWG 13)
the switching of 230/110 V AC mains voltage

-5°C to +40 °C
Ambient temperature
(+23 °F to +104 °F) Approvals / marking
Relative humidity max. 95 % See panels
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation


IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 170 g (0.4 lbs)
35 x 99 x 114.5 mm (WxHxD)
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)
301-420_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 26
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 Impulse valve reset module Part no.: 908324


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
The module contains all connections and functions for
controlling and resetting an impulse valve in water
extinguishing systems with 24 V DC operating voltage.
The operating positions of the valve are represented by two
LEDs. The order to reset the valve is given via an external
button connected to the module or a relay contact.
Can be installed in the extinguishing control panel or in a
separate housing with a mounting rail.

Product features Application


• Valve can also be closed via an external button The module is used for controlling impulse valves in water
• The open status of the valves can be displayed on a extinguishing systems. The impulse valve contains two coils,
connectable status display or forwarded via a relay one for opening and one for closing the valve. The valve will
remain in the last position if the power supply is switched off.
• Space-saving setup due to narrow module enclosure For opening or closing progress the respective coils can be
on a mounting rail controlled in impulse mode.

Included in delivery
Technical specifications Module completely assembled and ready for installation in
Operating voltage 19 V - 27 V DC the fire alarm panels with socket terminals
Quiescent current 20 mA DC
Permissible current
Not included in delivery
≤ 1 A DC Control group module, remote control buttons, external
open valve
displays, forwarding relay
Permissible current
≤ 1 A DC
close valve
External display voltage 24 V DC Connection / mounting
DIN hat rail as per IEC/EN 60715. Module can also be used
Permissible current
≤ 1 A DC in separete enclosure outside the extinguishing control panel.
external display
Max. terminal cross-section 2.5 mm2 (AWG 13)
-5 °C to +40 °C
Note
Ambient temperature The module does not monitor the supply to the open coil.
(+23 °F to +104 °F)
Control group module Part no. 901673 can be used to
Ambient temperature -10 °C to +70 °C
storage (+14 °F to +158 °F)
monitor the impulse valve open coil.
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 95 %


(IEC b721-3-3) no condensation Approvals / marking
IP rating (EN 60529) IP 20 See panels
Enclosure Polyamid PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 150 g (0.3 lbs)
17.5 x 93 x 108 mm (WxHxD)
Dimensions
0.7 x 3.9 x 4.5 inch (WxHxD)
301-420_009 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 27
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 ground fault module Part no.: 800096


Function module for monitoring and signalling a ground
fault. The module monitors in a connected device the
galvanic separation between protective earth (PE) and
all secondary DC voltages inclusive of the ground wire as
reference potential.

Product features Application


• Ground fault monitoring of lines carring direct current The ground fault module is fitted in the device to be
monitored or in its vicinity on a mounting rail. If the
• Function test by means of test button
resistance between the DC voltage potentials in the device
• Transmission through dry contact and open and the protective earth should drop below a certain value,
collector output then an open collector output is triggered for retransmission.
• Easy installation in alarm systems, as the event and For fire detection control panels, e.g. the cables of detector
terminating resistor are integrated for connection of groups, triggering of horns and supply voltages can be
a conventional detector group monitored.

Included in delivery
Technical specifications Module completly assembled and ready for the installation
in the fire alarm panels, inclusive connection and
Operating voltage 18 V - 30 V DC
commissioning instructions.
Quiescent current approx. 7 mA DC
Current in case of earth fault approx. 15 mA DC
Not included in delivery
Test voltage (IEC 950) 500 V AC, 700 V DC Test button
Resistance 0 V - PE approx. 620 kOhm
Response threshold approx. 50 kOhm Note
Terminal capacitance max. 20 µF As the GND lines of detector groups in explosive areas
Max. terminal cross-section 2.5 mm (AWG 13)
2 with the ignition protection type intrinsically safe Ex i are
connected with PE via an upstream Zener barrier, use of
-5 °C to +40 °C
Ambient temperature the module is not possible.
(+23 °F to +104 °F)
-10 °C to +50 °C
Storage temperature
Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

(+14 °F to +122 °F)


Relative humidity max. 95 % See panels
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 67 g (0.15 lbs)
19 x 81 x 70 mm (WxHxD)
Dimensions
301-420_010 / AI00_2015en

1.4 x 3.9 x 4.5 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 28
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 power distribution module Part no.: 904093


Module for use in all design variants of the fire alarm system
FMZ 5000. It includes protection elements for diverting over-
voltage to the protective earth.

Product features Application


• 6 terminals each to take 24V and GND for the supply The power distribution module is used for the
of connected devices star-configuration power supply of modules with high
• Protects connected devices from transient overvoltages output currents e.g. the control group module and
Loop module AP XP. It also diverts transient overvoltages
• No settings on the module are required from the modules to the protective earth. Normally a power
distributor is fitted at the end of a module row. One module
can be set per module row (via mounting rail).
Technical specifications
Operating voltage 19 V - 29 V DC
Included in delivery
Module completely assembled and ready for installation in
Output current 4 A DC the fire alarm panel
Max. terminal cross-section 2.5 mm2 (AWG 13)

Ambient temperature
-5 °C to +40 °C Not included in delivery
(+23 °F to +104 °F)
4 socket terminal strips FKCT 2.5/3-ST 901564
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Note
IP rating (EN 60529) IP 20
If the power distribution module is used to supply external
Enclosure Polyamide PA6.6, green devices directly, each outgoing 24 V supply must be fuse-
Installation position vertical protected. The module is not a substitute for surge arrestors
Mounting rail 35 DIN 46277,
necessary for lightning protection.
Mounting
top hat profile
Weight 85 g (0.2 lbs) Approvals / marking
22.5 x 99 x 114.5 mm (WxHxD) See panels
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

0.9 x 3.9 x 4.5 inch (WxHxD)


301-420_011 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 29
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 reflex module Part no.: 906262


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
The reflex module contains all components for flame
or spark detection, extinguishing and monitoring for
2 extinguishing zones where very fast fire detection and
virtually instantaneous extinguishing are of particular
importance. Conventional spark or flame detectors can
be connected to conventional detector technology.
All connected detectors and extinguishing components
and their wiring are monitored for wire breakage and
short circuits. In addition, fault signals from self-monitoring
detectors are processed and displayed.

Product features Application


• Instant fire detection and extinguishing for two The reflex module is used for fire protection in pneumatic
mutually independent extinguishing zones conveying systems, painting facilities, machine tools
• Display of fire alarm messages and extinguishing or wherever there is a risk of rapidly spreading fires.
events accurate to the millisecond Instantaneous ejection of combustible material is likewise
possible.
• Spark counter for maximum number or average In painting facilities, flames caused by high voltage
of detected sparks per unit of time, in order to flashovers are extinguished immediately by cutting off the
e.g. carry out machine shutdowns supply of paint and applying extinguishing agents through
the paint spray nozzles.
In machine tools, the machining process is monitored and in
the event of the machined material or cooling agent catching
Technical specifications fire, the tool is stopped immediately and extinguishing can be
Operating voltage 19 V - 27 V DC initiated instantly.
Quiescent current 30 mA DC
Number of detector lines 2 Included in delivery
Number of control groups 2 Module completely assembled and ready for installation in
the fire alarm panel
Number of monitoring lines 4
8 spark detectors
No. of detectors per line
4 flame detectors Not included in delivery
12 socket terminal strips FKCT 2.5/3-ST 901564
Maximum current
2.6 A DC
per control group
No extinguishing, extinguishing Note
Functions monitored time too long, leakage, blockage, Up to 40 modules can be used in one fire alarm panel
detector fault
The contents of this publication are subject to modifications without notice. All rights reserved.

All lines for wire breakage, Approvals / marking


Line monitoring
short circuits
See panels
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
301-420_012 / AI00_2015en

Weight 290 g (0.6 lbs)


53 x 99 x 114.5 mm (WxHxD)
Dimensions
2.1 x 3.9 x 4.5 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 30
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 spark test 8 module Part no.: 906980


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
The spark test module contains 8 outputs each for
connecting one test actuator. The actuators can be
manually triggered or triggered at freely configurable test
times by the spark test module, with multiple tests possible
in one day. For testing, the actuator emits a light pulse of
defined intensity. The intensity can be manually pre-set or
automatically learned by the system.
When triggering, the module checks whether the test
actuator is connected. The test actuators can be assigned
during configuration to any spark detector group in the
fire alarm panel.

Product features Application


• Function testing while the monitored facility is in The spark test module 8 is used for testing spark detectors
operation, for up to eight spark detector groups during ongoing operation of the monitored production facility.
The test actuators are installed opposite the spark detectors.
• Individual test conditions for each detector group,
The test is perfectly adapted to practical requirements, as
because test light intensity can be manually pre-set
the light pulses need to be sent and detected through the
or can be learned independently by the system during
flow of material during operation of the facility.
operation
Any light pulses not detected by the spark detector are
• The spark test is carried out without interrupting reported as a fault. The detected light pulse can also trigger
operation of the monitored facility extinguishing, if desired.
• All settings are carried out with the MxSysCon Up to 8 modules can be used in one panel.
configuration program
Included in delivery
Module completely assembled and ready for installation in
Technical specifications the fire alarm panel
Operating voltage 19 V - 27 V DC
Quiescent current 20 mA DC
Not included in delivery
8 socket terminal strips FKCT 2.5/3-ST 901564
Number of test actuators 8
Max. test current 3 A DC
Note
Connection and functioning
Functions monitored The module contains all required components and no other
of the test actuator
modules are needed for operation.
Max. terminal cross-section 2.5 mm2 (AWG 13) The module can only be used in connection with spark
-5 °C to +40 °C detector lines of Reflex modules.
Ambient temperature
(+23 °F to +104 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 95 % Approvals / marking


(IEC 721-3-3) no condensation
See panels
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 160 g (0.3 lbs)
35 x 99 x 114.5 mm (WxHxD)
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)
301-420_013 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 31
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 MxNet module Part no.: 904877


Functional module for use in all design variants of the
fire alarm systems FMZ 5000, as well as mimic panels and
operating panels.
Allows devices to be connected in a line-redundant loop
network. Communication with the connected devices takes
place via a serial interface in RS-232 standard.
All data lines are continuously monitored. In the event of
line faults in the network, line redundancy means that the
functions of the devices are not affected.
The module is supplied with power by the networked device.

Product features Application


• Communication to the networked devices uses The module enables a device to communicate with other
the MX2 protocol in all versions devices in a loop network. The signals from the devices
can be displayed at several central control points. Likewise,
• Up to 32 devices can be networked in a ring
commands to the devices are possible from different points in
• No adjustment work is required the network and from outside the network (control stations).
Each network participant a module required.

Technical specifications Included in delivery


Operating voltage 19 V - 29 V DC Module completely assembled and ready for installation in
the fire alarm panel
Quiescent current 58 mA DC
COM1 RS-232 SUB-D socket
Outputs Path 1 RS-485 modular terminal Note
Path 2 RS-485 modular terminal All parameters can be set using jumpers.
Max. terminal cross-section 2.5 mm2 (AWG 13) Module is preconfigured by jumpers.
Alternatively the module and the network can be configured
-5 °C to +40 °C
Ambient temperature centrally using the configuration program “MxNet.exe”.
(+23 °F to +104 °F)
Use of the module in a FMZ 5000 fired detection control
Relative humidity max. 95 % panel requires additionally a
(IEC 721-3-3) no condensation module SIO1 903466
IP rating (EN 60529) IP 20 or
Enclosure Polyamide PA6.6, green
module SIO3 903467

Installation position vertical The module must be placed directly to the right of the SIO
module. Activation is done via the R-232 interface by means
Mounting rail 35 DIN 46277,
Mounting
top hat profile
of a ribbon cable.
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 200 g (0.4 lbs)


Approvals / marking
35 x 99 x 114.5 mm (WxHxD)
Dimensions See panels
1.4 x 3.9 x 4.5 inch (WxHxD)
301-420_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 32
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 WEBmodule N cpl. Part no.: 914365


Functional module for use in mod 12 and mod XL
variants of the FMZ 5000 fire alarm system.
The module is intended for the communication with a fire
alarm panel via the TCP/IP protocol.
It contains an interface according to the RS-232 standard
for communication with the control panel over module
SIO1 (Part no.: 903466) or SIO3 (Part no.: 903467) via the
Mx2 protocol. The connection of the IP network occurs via
patch panel to the Ethernet interface with a RJ-45 female
connector.

Product features Application


• Remote polling messages and statuses of The messages transmitted per Web browser by a fire
fire detection control panels alarm panel to a PC can be displayed and stored via
• Display of the messages and statuses in a web browser WEBmodule from any location.
Time synchronization procedures between fire alarm panel
• Messages can be stored to a remote FTP server and WEBmodule are possible.
• For better evaluation, messages can be repeatedly These remote diagnostics optimal scheduling of service
filtered interventions and increased availability of the fire detection
• Option of time synchronization by NTP Timeserver system.

Included in delivery
Technical specifications Module ready for installation into the control panel.
SIO-Adapter FMZ WEBmodule
Operating voltage 19 V - 28 V DC (Connection SIO-Module WEBmodule) 909409
Quiescent current 80 mA at 24 V DC Patch Panel 914347
Cabel Patch cabel CAT6 1.0 m (39 inch)  914349
Rated current 115 mA at 24 V DC
1 RS-232
Data interfaces
1 Ethernet Note
-40 °C to +85 °C
Use a CAT5 or higher category cable for field network
Storage temperature connection on the patch panel.
(-40 °F to +185 °F)
In order to preserve electromagnetic compatibility the
-0 °C to +65 °C
Ambient temperature direct interconnection between WEBmodule and field
(+32 °F to +149 °F)
network installations is not permitted.
Relative humidity max. 90 % Only use the equipment supplied (patch cable, patch panel)
(IEC 721-3-3) no condensation to connect the WEBmodule to the field network installation.
IP rating (EN 60529) IP 20 Max. cable length for the RS-232 interface 10 m (390 in).
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure Polyamide PA6.6, green Any unauthorized access to the control panel must be
prevented by suitable IT protection measures to be taken
Installation position vertical by the customer.
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 162 g (0.35 lbs)
52 x 99 x 114 mm (WxLxH)
Dimensions
2.1 x 3.9 x 4.5 inch (WxLxH)
301-420_015 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 33
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 WEBmodule S cpl. Part no.: 914366


The version WEBmodule S can send switching commands
to the connected control panel (deactivates and activates
detectors and groups, revision mode, user reset).

Otherwise like part no.: 914365


The contents of this publication are subject to modifications without notice. All rights reserved.
301-420_015 / AI00_2015en

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 34
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 remote transmission unit module Part no.: 901969


Functional module for use in all design variants of the fire
alarm system FMZ 5000. Includes monitoring and control
for 2 remote transmission units (RTU). Each RTU can be
used to transmit either fire or fault signals.
In addition
- a fire brigade control panel (FBF) in acc. with DIN 14661
- a fire brigade key depot (FSD) in accordance with German
standard VdS 2105 can be connected using adapter.

Product features Application


• For interface connection with two remote For monitoring and controlling 2 remote transmission units
transmission units for fire or fault signals for fire or fault signals to the fire brigade or service points.
• Control can be pulsed or continuous If a fire brigade control panel is connected, the module
controls all the displays on the display panel and polls the
• All settings of the module and the remote operator controls.
transmission units are carried out with the With a fire brigade key depot connected, the door opener is
MxSysCon configuration program activated after a fire brigade call has been issued and the
• No adjustment work is required position of the door and the presence of the deposited key is
monitored. A maximum of one module can be used in one fire
alarm panel.

Technical specifications
Included in delivery
Operating voltage 19 V - 29 V DC
Module completely assembled and ready for installation in
Quiescent current 25 mA DC the fire alarm panel
2 RTUs, fire / fault
Outputs 1 fire brigade control panel
1 fire brigade key depot Not included in delivery
2 socket terminal strips FKCT 2.5/4-ST 901565
Output voltage 24 V DC
Output current 1 A DC per remote transmission unit
Note
Control continuous, pulsed
When activating a key depot a suitable adapter must be used
Max. terminal cross-section 2.5 mm2 (AWG 13) as well
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Approvals / marking
Relative humidity max. 95 % See panels
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation


IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 200 g (0.4 lbs)
45 x 99 x 114.5 mm (WxHxD)
Dimensions
1.8 x 3.9 x 4.5 inch (WxHxD)
301-420_016 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 35
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 SIO1 module Part no.: 903466


Functional module for use in all design variants of the fire
alarm system FMZ 5000.
Includes a serial communication channel in RS-232
standard. Preferred for data transmission to an WEBmodule,
a MxNet module or a report printer. The module status is
indicated by 3 LEDs.

Product features Application


• An RS-232-standard serial interface is connected For serial data transmission in RS-232 standard.
to an SUB-D socket When using the Minimax data protocol MX2, all signals
from the fire alarm panel can be sent to control stations or
• Baud rates adjustable from 300 to 115.200 baud.
visualisation programs and commands can be received from
• All settings of the module, the application and the them. Up to 3 modules can be used in one fire alarm panel.
communication parameters are carried out with
the MxSysCon configuration program.
Included in delivery
Module completely assembled and ready for installation in
the fire alarm panel
Technical specifications
Operating voltage 19 V - 29 V DC Not included in delivery
Quiescent current 42 mA DC SUB-D plug, 9-pin
Outputs COM1 RS-232 SUB-D socket
Max. terminal cross-section 2.5 mm2 (AWG 13) Note
-5 °C to +40 °C The interface is not opto-isolated.
Ambient temperature If devices outside the fire alarm panel system are connected,
(+23 °F to +104 °F)
these must be opto-isolated using a separate converter.
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20 Approvals / marking
Enclosure Polyamide PA6.6, green See panels
Installation position vertical
Mounting rail 35 DIN 46277,
Mounting
top hat profile
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 100 g (0.2 lbs)


22.5 x 99 x 114.5 mm (WxHxD)
Dimensions
0.9 x 3.9 x 4.5 inch (WxHxD)
301-420_017 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 36
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 SIO3 module Part no.: 903467


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
Includes a serial communication channel in RS-232
standard plus two serial communication channels in
RS-422 / 485 standard. One RS-422 / 485 channel is
opto-isolated for interface connection with devices with an
external power supply.
The module status is indicated by 9 LEDs.

Product features Application


• The RS-232 serial interface is connected to For serial data transmission in RS-232, RS-422 or
a 9-pin SUB-D socket RS-485 standard.
When using the Minimax data protocol MX2, all signals
• The RS-422 / 485 serial interfaces (one opto-isolated)
from the fire alarm panel can be sent to control stations or
are connected to series terminal
visualisation programs and commands can received from
• Baud rates are adjustable from 300 to 115.200 them. Devices with their own power supply can be connected
• All settings of the module, the communication directly to the opto-isolated communication channel.
parameters and the application are carried out with Up to 2 modules or a total of 6 data channels can be used
the MxSysCon configuration program in one fire alarm panel.

Included in delivery
Technical specifications Module completely assembled and ready for installation in
the fire alarm panel
Operating voltage 19 V - 29 V DC
Quiescent current 58 mA DC
Not included in delivery
COM1 RS-232 SUB-D socket
SUB-D plug, 9-pin
COM2 RS-422 / RS-485 4 Socket terminal strips FKCT 2.5/4-ST 901565
Outputs opto-isolated series terminal
COM3 RS-422 / RS-485
series terminal
Max. terminal cross-section 2.5 mm2 (AWG 13)
Note
Slide switches are used to switch over from RS-422
-5 °C to +40 °C
Ambient temperature to RS-485 and to activate the bus terminating resistor.
(+23 °F to +104 °F)
Only use opto-isolated interfaces for data transmission to
Relative humidity max. 95 % external devices or arrange for separate opto-isolation.
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation The RS-485 interface cannot be used for data transfer with
IP rating (EN 60529) IP 20 MX 2 protocol.
Enclosure Polyamide PA6.6, green
Installation position vertical Approvals / marking
Mounting rail 35 DIN 46277, See panels
Mounting
top hat profile
Weight 190 g (0.4 lbs)
45 x 99 x 114.5 mm (WxHxD)
Dimensions
1.8 x 3.9 x 4.5 inch (WxHxD)
301-420_018 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 37
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 Modbus module Part no.: 904566


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
The module includes an serial interface RS422 standard
for communication using the Modbus protocol. It supports
the Modbus RTU format. The Modbus module is always the
Modbus slave and must be queried by a Modbus master.
Each slave can be assigned an address in the range of 1-99.

Product features Application


• All parameters for the transmission of data to a For the transmission of signals and system states
Modbus master are configurable from the FMZ 5000 fire alarm panel to a control station
• Communication to the Modbus master can be (Modbus master) via the Modbus RTU protocol.
point to point Operations such as isolations or resets are also possible
from the control station to the panel.
• All settings are carried out with the MxSysCon Using separate converter modules connected in series,
configuration program the transmission can also be carried out using other field
• No adjustment work is required bus protocols (e.g. Profibus via adapter).
A maximum of 2 Modbus modules can be used in one
fire alarm panel.

Technical specifications
Included in delivery
Operating voltage 19 V - 29 V DC
Module completely assembled and ready for installation in
Quiescent current 58 mA DC the fire alarm panel
COM1 RS-232 SUB-D socket
Outputs COM2 RS-422 Not included in delivery
opto-isolated modular terminal
4 Socket terminal strips FKCT 2.5/4-ST 901565
Max. terminal cross-section 2.5 mm2 (AWG 13)
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Note
Relative humidity max. 95 % The use of the Modbus module is always subject to
(IEC 721-3-3) no condensation
greatly differing, project-specific requirements. Therefore
IP rating (EN 60529) IP 20 the required range of functions and all conditions must be
Enclosure Polyamide PA6.6, green defined at an early stage with all project participants and
The contents of this publication are subject to modifications without notice. All rights reserved.

the parties responsible for the modbus master.


Installation position vertical
If your project requires an RS-458 interface, use the Modbus
Mounting
Mounting rail 35 DIN 46277, RS-458 (906853) module. The RS-232 interface is not suitab-
top hat profile le for Modbus communication
Weight 200 g (0.4 lbs)

Dimensions
45 x 99 x 114.5 mm (WxHxD) Approvals / marking
1.8 x 3.9 x 4.5 inch (WxHxD) See panels
301-420_019 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 38
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 Modbus RS-485 module Part no.: 906853


The module uses an RS-485 serial interface for
communication by means of a Modbus protocol.

Note
If an RS-422 interface is required in the project, the module
Modbus (904566) must be used. The RS-232 interface is
not provided for Modbus communication.

Otherwise like part no. 904566

Product features
Several Modbus modules can be interconnected in bus
operation.

Technical specifications
COM1 RS-232 SUB-D socket
Outputs COM2 RS-485
opto-decoupled modular terminal
The contents of this publication are subject to modifications without notice. All rights reserved.
301-420_019 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 39
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

24 V to 9 V voltage converter module Part no.: 908471


Function module for use of all detectors with 9 V
operating voltage (e.g. Minimax detectors) on any
fire alarm control panels.
The module lowers the voltage to a set value and transfers
the standby- and alarm current of the connected detectors.
When using detectors for hazard areas with a risk of
explosion the requirements of detectors protected against
explosion must be observed.
When using detectors with the „Intrinsic Safety“ protection
type the prescribed safety barriers are to be used.

Product features Application


• Fixed voltage regulation to 9.5 V output voltage Detectors suitable for connection:
see detectors with corresponding voltage range and
• Space-saving assembly via narrow module housing
for monitoring of exhaust- and air conditioning ducts.
on mounting rail
BMX1001 Bypassbox  719754
Applicable safety barrier with suitable detectors:
Safety barrier Ex Standard 9 V  904991
Technical specifications
Operating voltage 15 V - 28 V DC Included in delivery
Current consumption 0.05 mA - 0.1 mA DC Module completly assembled and ready for installation in the
Output voltage 9.5 V DC fire alarm panels with connecting plugs.
Short circuit disconnection
125 mA DC
output Connection / mounting
Fuse output thermally self-resetting On TH 35 mounting rail in accordance with IEC/EN 60715.
Module can also be inserted in separate housings outside
Conductor cross-section 2.5 mm 2
the fire alarm control panel.
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
-20 °C to +70 °C
Connection diagram
Storage temperature
(-4 °F to +158 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Housing Polyamid PA6.6, green
The contents of this publication are subject to modifications without notice. All rights reserved.

Mounting position vertical


35 DIN 46277 mounting rail, cap
Mounting
profile
Weight 150 g (0.3 lbs)
23 x 100 x 100 mm (WxHxD)
Dimensions
0.9 x 3.9 x 3.9 inch (WxHxD)

Approvals / marking
See panels
301-420_020 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 40
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 reverse voltage module Part no.: 915945


Functional module for connection of alarm devices by
using a polarity switchover.
The module FMZ 5000 reverse voltage realizes a polarity
switchover of one or two primary control groups within the
fire detection and extinguishing control panel. When in idle
state, the alarm devices are connected with „reversed“
polarity. The polarity is changed back in activated condition
and the alarm devices activate.

Product features Included in delivery


• Polarity switchover for controlling of alarm devices 1 Module (ready-to-install) with all connecting terminals
2 End-of-line resistors (EOL) 1k / 3/4W
• 2 switchover circuits, electrically separated from
1 Product information
one another
• For a polarity switchover of one or two primary control
groups Note
• Easy installation in alarm systems using mounting rail All alarm devices in the Minimax product portfolio can be
(DIN rail) operated with reverse voltage.

Connection diagram
Technical specifications
Operating voltage 19 V - 29 V DC
Quiescent current 0 mA
Max. contact rating max. 3 A at 30 V DC
*
Number of switchover circuits 2
**
Max. terminal cross-section 2,5 mm2 (AWG 13)
-5 °C to +40 °C
Operating temperature
(+23 °F to +104 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure Polyamide PA6.6, green * All Mx alarm devices have a diode included
Installation position vertical ** End-of-line resistor (EOL) included in delivery (2 pieces)

Mounting rail 35 DIN 46277,


Mounting
top hat profile
Optionally, the control group 3 and/or 4 or also control
groups of different control group modules can be used.
Weight 70 g Both switchover circuits of the module FMZ 5000 reverse
19x81x70 mm (WxHxD) voltage are electrically separated from one another.
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)

Approvals / marking
See panels
301-420_021 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 41
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

Card interface module V11 Part no.: 852278


Functional module for use in all design variants of the
fire alarm system FMZ 5000.
Includes opto-isolated, serial communication channels in
RS-232 and RS-422 / RS-485 standard.
Preferred for data transmission to an SIO1 or SIO3 Modul,
WEBmodule, MxNet module or a report printer. The module
status is indicated by 3 LEDs.

Product features Application


• 10 m (33 ft) maximum cable length between The interface module V11 can be used for interface
SIO1 or SIO3 Modul (COM 1) and interface module V11 conversion from RS-232 to RS-422 / RS-485 and reverse.
• 1200 m (3937 ft) maximum cable length between It serves the extension the length from 10 m (394 inch
SIO3 COM 1 or COM 3 and interface module V1 (RS-232)) to a maximum of 1.200 m (3.937 ft (RS-422 /
RS-485)). The interface module V11 has to be mounted
• 1200 m (3937 ft) maximum cable length in enclosure of the FMZ 5000 panel.
between two V11 interface modules

Included in delivery
Card interface module V11
Technical specifications
Operating voltage 12 V - 24 V DC Not included in delivery
Quiescent current approx. 25 mA Cable connection 800497
COM1 RS-232 SUB-D socket
Output
COM2 RS-422 series terminal
Conductor cross-section 2.5 mm2 (AWG 13)
-5 °C to +40 °C
Operating temperature
(+23 °F to +104 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation

Mounting
Mounting rail 35 DIN 46277,
top hat profile
Weight 55 g (0.12 lbs)
51 x 68 mm (BxH)
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

2.0 x 2.7 inch (BxH)


301-420_024 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 42
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

Loop AP protocol interface Part no.: 901322


Control device for the operating of „intrinsically safe Ex i“
detectors in explosion hazard areas together with a safety
barrier.

Product features Application


• Connection-ready device for mounting The protocol interface is switched to the detector loop,
on a TS35 mounting rail (DIN rail) forming a spur.
• No adjustment or maintenance work required After the protocol interface the safety barrier,
part no. 901324, must be switched to the spur.
• Spur from Loop AP required

Included in delivery
1 Loop AP protocol interface
Technical specifications
Operating voltage 19 - 28 V DC Connection diagram
Output voltage 16.5 - 19 V DC
Current consumption input 1 mA DC
Maximum current output 30 mA DC
Current pulse input 8 - 12 mA DC
Current pulse output 17 - 23 mA DC
-20 °F to +60 °C
Operating temperature
(-4 °F to +140 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Mounting rail 35 DIN 46277,
* Optionally the Module Loop AP XP (906185) or the
Mounting
top hat profile
Module Loop AP XP red (906186) module can be used

Site of installation Secure area / non Ex area


Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 100 g (0.2 lbs)


20 x 92.5 x 111 mm (WxHxD)
Dimensions 0832-CPD-0858
0.8 x 3.6 x 4.4 inch (WxHxD)

Loop AP protocol interface for 2 lines Part no.: 901323

Technical specifications
Current consumption input 2 mA DC
Otherwise like part no.: 901322
301-420_025 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 43
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

Safety barrier Ex Loop AP 24 V Part no.: 901324


Control device for the operation of “intrinsically safe Ex i”
detectors in explosion hazard areas.
The safety barrier limits the power supplied to an intrinsically
safe electric circuit in such a way that neither sparks nor
thermal effects can cause an ignition.
The intrinsically safe electric circuit of the safety barrier is
suitable for zones 1 and 2 as well as zones 21 and 22.
VDE0105 Part 9 applies to the operation of electrical
systems in potentially explosion hazard areas.

Product features Application


• Device ready for connection for mounting on a mounting The safety barrier is connected to a spur line of the detector
rail TS35 (DIN rail) loop.
• No adjustment or maintenance work required The Loop AP protocol inerface, part no.: 901322,
needs to be connected in front of the safety barrier.
• Galvanic isolation of the input from the safety area

Included in delivery
1 safety barrier Ex Loop AP 24 V
Technical specifications
Rated voltage UN = max. 26 V Note
Output voltage UA = UN - (0,38 x I [mA]) - 0.5 For the interconnection of intrinsically safe detectors to
Maximum current 93 mA DC the intrinsically safe electric circuit of the safety barrier,
the corresponding maximum values of the detectors need
Maximum external to be observed.
0.077 μF; 4.3 mH
connection values IIC
The maximum permissible values for capacitive and inductive
Maximum external loads must be complied with.
0.39 μF; 12.6 mH
connection values IIB The safety barrier must be connected to the potential
-20 °C to +60 °C equalisation within the explosion hazard area. Potential
Ambient temperature
(-4 °F to +140 °F) equalisation in accordance with IEC 60079-14/EN 60079-14
Relative humidity max. 90 % must exist for all intrinsically safe electric circuits. When
(IEC 721-3-3) no condensation setting up intrinsically safe electric circuits in explosion
hazard areas, the corresponding applicable national and
IP rating (EN 60529) IP 20
international setup regulations need to be observed.
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Connection diagram
Safe area / not potentially
The contents of this publication are subject to modifications without notice. All rights reserved.

Mounting location
explosive area
Weight 100 g (0.2 lbs)
20 x 107 x 115 mm (WxHxD)
Dimensions
0.8 x 4.2 x 4.5 inch (WxHxD)

Approvals / marking
Ex conformity in acc. with 94/9/EC x II (1)GD EEx ia IIC
Ex conformity Russia in acc. with TP TC 012/2011:
[Ex ia Ga] IIC
[Ex ia Da] IIIC * Optionally the Module Loop AP XP (906185) or the
301-420_026 / AI00_2015en

Module Loop AP XP red (906186)can be used

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 44
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

Safety barrier IS conventional 9 V Part no.: 904991


Safety barrier for the operation of detectors type
“intrinsically safe Ex ib” in potentially hazardous areas.
The safety barrier limits the power supply to an intrinsically
safe electrical circuit that neither sparks nor thermal effects
can cause an ignition. The safety barrier is suitable for zones
1 and 2 as well as zones 21 and 22.
VDE0105 Part 9 applies to the operation of electrical
systems in potentially hazardous areas.

Product features Application


• Device ready for connection and mounting on a rail TS35 The safety barrier is connected to a conventional line
• No adjustment or maintenance work required
Included in delivery
1 Safety barrier IS conventional 9 V
Technical specifications
Rated voltage UN = 9 V DC; max. 10.6 V DC
Note
For the connection of intrinsically safe detectors to the
Output voltage UA = UOn - 1.4 V at 75 mA DC
intrinsically safety barrier, the corresponding parameters
Rated current IN = 85 mA DC values of the detectors need to be observed.
-20 °C to +60 °C The maximum permissible values for capacitive and
Ambient temperature inductive loads must be observed.
(-4 °F to +140 °F)
The safety barrier must be connected to the potential
Relative humidity max. 90 %
(IEC 721-3-3) no condensation
equalisation within the potentially hazardous area. Potential
equalisation in accordance with IEC 60079-14/EN 60079-14
IP rating (EN 60529) IP 20 must exist for all intrinsically safe electric circuits.
Mounting rail 35 DIN 46277, When setting up intrinsically safe electric circuits in potentially
Mounting
top hat profile hazardous areas, the corresponding applicable national and
Safe area / international setup regulations need to be observed.
Mounting location
not potentially explosive area
Weight 175 g (0.4 lbs) Connection diagram
22.5 x 79 x 85.5 mm (WxHxD)
Dimensions
0.9 x 3.1 x 3.4 inch (WxHxD)

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

Ex conformity in acc. with 94/9/EC x II 2G [Ex ib] IIC


x II 2D [Ex ibD]
x I M2 [Ex ib] I
Ex conformity Russland in acc. with TP TC 012/2011:
[Exib] IIC
301-420_027 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 45
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 central card Part no.: 910708


The central control card constitutes the main unit of the
FMZ 5000 fire alarm- and extinguishing control panel.
Includes all the components for communicating with the
modules used in the panel, the front panel for displaying
messages and for operating the panel. In addition the
firmware and project-related settings for the panel are stored.
A licence for the operating system is automatically delivered
with each central card.

Application
Technical specifications
Card exclusively as replacement part to be exchanged
Operating voltage 24 V DC ± 15 % for a defective card in an existing FMZ 5000 fire alarm
Quiescent current approx. 110 mA DC control panel mod 4, mod 12, mod XL 21 HE, mod XL 31 HE
or mod XL 40 HE.
- 5 °C to + 40 °C
Operating temperature
(+23 °F to +104 °F)
Weight 248 g (0.6 lbs) Included in delivery
245 x 165 mm (BxL)
Card complete for exchange in an existing FMZ 5000
Dimensions fire alarm control panel.
9.7 x 6.5 inch (BxL)

Not included in delivery


CompactFlash memory card  905881
Connection cable, plug, mounting accessories

Spare parts
Encoding connector AKSN/G (Jumper) 805412

Note
When swapping out the card take all ESD precautions.
In each case before exchanging the card, turn off the
panel and disconnect from mains voltage. Observe
correct seating of the foil connections to the front foil and
the ribbon cable plugs.
Insert the CompactFlash memory card from the defective
central card. You may have to insert a new memory card
The contents of this publication are subject to modifications without notice. All rights reserved.

provided by Minimax. In this case the configuration data


must be loaded directly on to the new card or via download
using the MxSysCon configuration program.
The central card contains the latest version of the firmware.
In each case the compatibility of the firmware with the version
of all in the panel installed modules and of the configuration
data on the memory card must be checked.

Approvals / marking
See panels
301-420_028 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 46
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 central card redundant Part no.: 910707


Card for achieving the processor redundancy in compliance
with EN54-2 and VdS2095 if during application of the control
panel at least one of the following cases applies:
- More than 512 detectors are connected
- The monitored area is larger than 12.000 m2 (1.435 ft)
- More than one extinguishing zone is triggered.
The card is inserted into the plug strips X1 and X2
of the central card.

Technical specifications Spare parts


Coding plug AKSN/G (jumper) 805412
Weight 70 g (0.2 lbs)
135 x 100 x 20 mm (WxLxH)
Dimensions
5.3 x 3.9 x 0.8 inch (WxLxH) Approvals / marking
See panels

CompactFlash 256 MB memory card Part no.: 905881


CompactFlash memory card with ATA communications
interface and 256 MByte capacity for use in the FMZ 5000
control card. The card has an extended temperature range
of -40 °C to +85 °C (-40 °F to 185 °F).
The card is used for saving current and past states of the
fire alarm- and extinguishing control panel.
It is also used to store the control panels configuration data.
Apart from the control unit the card can be read or written to
with any memory card reading device.

Technical specifications Included in delivery


256 MB CompactFlash memory card without data
Memory capacity min. 256 MB
-40 °C to +85 °C
Not included in delivery
The contents of this publication are subject to modifications without notice. All rights reserved.

Operating temperature
(-40 °F to +185 °F)
Read/write device for external reading or writing
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
in socket on the fire alarm
Note
Mounting The CompactFlash memory card should be formatted before
central card
first use. Only those CompactFlash memory cards with the
Weight 9 g (0.02 lbs)
extended temperature range are authorised for use in the
42 x 36 x 4 mm (BxLxH) FMZ 5000.
Dimensions
1.7 x 1.4 x 0.2 inch (BxLxH)
301-420_029/ AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 47
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 modules/cards

FMZ 5000 zone operating panel card Part no.: 901518


Card for use in all design varriants of the FMZ 5000
fire alarm panel system.
Includes 16 groups with one red and one yellow LED each
and 4 membrane keys with freely configurable function.
In addition there are 4 connections for uses such as
key-operated switches on the front plate.
Labeling is by means of sliding labels behind transparent
windows - at front plate BBF, one window per zone operating
panel, LED group and membrane key.

Product features Application


• Each LED can be configured for indication by steady For displaying individual indications of signals, faults,
light, flashing and rapid flashing activations, shutdowns etc.
• Each membrane key can be used as a switching Up to 27 cards can be used in one fire alarm panel.
actuator or a momentary-contact actuator
• All settings are carried out with the MxSysCon Included in delivery
configuration program Card, separate or as part of a complete retrofit kit including
• No adjustment work is required mounting accessories for installation behind the front plate.
Complete retrofit kit 903340
includes:
Zone operating panel card 901518
Technical specifications Mounting accessories  904981
Artwork master 50 BBF  903282
Operating voltage 19 V - 29 V DC
Quiescent current 10 mA DC
Not included in delivery
-5 °C to +40 °C
Ambient temperature Front plate FMZ 5000 BBF  901733
(+23 °F to +104 °F)
Relative humidity max. 95 %
(IEC 721-3-3) no condensation Note
Mounting on the rear side of the front plate Connected switches/buttons must not be fitted outside the
central fire alarm system.
Weight 40 g (0.1 lbs)
70 x 113 mm (WxH)
Dimensions
2.8 x 4.5 inch (WxH) Approvals / marking
See panels
The contents of this publication are subject to modifications without notice. All rights reserved.
301-420_030 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 48
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 enclosure/front plates

Front plate FMZ 5000 BBF Part no.: 901733


Front plate for housing up to five zone operating panels.
Has 16 red/yellow LED pairs and four membrane keys for
each panel.
Labeling fields as headers for each zone operating panel
and one labeling field for each LED pair, designed to accept
sliding labels.

Technical specifications Not included in delivery


Card FMZ 5000 zone operating panel 901518
Colour RAL 7035 Add-on kit FMZ 5000 front panel BBF  904119
Material Aluminium Retrofit kit FMZ 5000 BBF 903340
Weight 750 g (1.7 lbs)
Pan-head screw with washer M6 x 16 607284

Dimensions 19” x 4U (WxH)

Front plate FMZ 5000 printer AP 1200 Part no.: 906231


Front plate with breakout for mounting a Printer AP 1200
in a FMZ 5000 mod 12 or mod XL.

Technical specifications Included in delivery


Colour RAL 7035 Front plate complete for mounting in a FMZ 5000.
The contents of this publication are subject to modifications without notice. All rights reserved.

Material Aluminium
Weight 750 g (1.7 lbs)
Not included in delivery
Nut KM6 „cage nut“  138670
Dimensions 19” x 4U (WxH) Pan-head screw with washer M6 x 16 607284
301-450_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 49
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 enclosure/front plates

Dummy plate 1U Part no.: 905492


Dummy plates for covering unused areas on the front of
Technical specifications panel enclosures FMZ 5000 mod 12 and mod XL.
Colour RAL 7035
Material Aluminium Not included in delivery
Weight 190 g (0.4 lbs) Pan-head screw with washer M6 x 16 (1 piece) 607284
Nut KM6 „cage nut“ (1 piece)  138670
Dimensions 19” x 1U (WxH)

Dummy plate 2U Part no.: 902411

Technical specifications Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour RAL 7035
Material Aluminium
Not included in delivery
Weight 360 g (0.8 lbs)
Pan-head screw with washer M6 x 16 (1 piece) 607284
Dimensions 19” x 2U (WxH) Nut KM6 „cage nut“ (1 piece)  138670

Dummy plate 3U Part no.: 902412


Dummy plates for covering unused areas on the front of
Technical specifications panel enclosures FMZ 5000 mod 12 and mod XL.
Colour RAL 7035
Material Aluminium Not included in delivery
Pan-head screw with washer M6 x 16 (1 piece) 607284
Weight 540 g (1.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Nut KM6 „cage nut“ (1 piece)  138670


Dimensions 19” x 3U (WxH)

Dummy plate 4U Part no.: 902413


Dummy plates for covering unused areas on the front of
Technical specifications panel enclosures FMZ 5000 mod 12 and mod XL.
Colour RAL 7035
Material Aluminium Not included in delivery
Pan-head screw with washer M6 x 16 (1 piece) 607284
Weight 765 g (1.7 lbs)
Nut KM6 „cage nut“ (1 piece)  138670
301-450_002 / AI00_2015en

Dimensions 19” x 4U (WxH)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 50
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 enclosure/front plates

Dummy plate 5U Part no.: 902414


Dummy plates for covering unused areas on the front of
Technical specifications panel enclosures FMZ 5000 mod 12 and mod XL.
Colour RAL 7035
Material Aluminium Not included in delivery
Pan-head screw with washer M6 x 16 (1 piece) 607284
Weight 895 g (2 lbs)
Nut KM6 „cage nut“ (1 piece)  138670
Dimensions 19” x 5U (WxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-450_002 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 51
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 printer

Printer FMZ 5000 AP 1200 Part no.: 906263


Log printer for installation in a front panel of the fire
detection panel FMZ 5000 mod 12 or mod XL.
The printer logs all messages and states with type of
message, message text, date and time. The printout can
be formatted by configuration.

Technical specifications Included in delivery


Printer FMZ 5000 AP 1200.
Operating voltage 5 V - 8,5 V DC
Current consumption while
printing
2 A - 10 A DC Not included in delivery
Installation material, power supply unit, front plate,
Data interface RS-232 to SIO-Module
printer paper
Print methode Thermal printing
Characters per line 32 to 42 Note
Paper width 57.5 mm (2.3 inch) Character set of the printer is IBM 224, Codepage 437.
Loading paper Front door If language of the fire detection panel is set in Chinese,
Cyrillic or Hebrew, a printer with the corresponding character
0 °C to +50 °C
Operating temperature
(+32 °F to +122 °F)
set must be used for printing messages.

Material Plastic
Mounting in front plate
IP rating(EN 60529) IP 40
Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Weight 0.31 kg (0.68 lbs)
115 x 67 x 104 mm (BxHxT)
Dimensions
4.5 x 2. x 4.1 inch (BxHxT)

Printer FMZ 5000 AP 1200 complete Part no.: 907345


The contents of this publication are subject to modifications without notice. All rights reserved.

Included in delivery
Printer FMZ 5000 AP 1200 together with power supply
unit, installation material, cable, front plate 19” x 4U with
breakout for mounting the printer.

Not included in delivery


Printer paper

Otherwise like part no.: 906263


301-480_001 / AI00_2015en

1/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 52
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 printer

Printer FMZ 5000 AP 1200 chinese Part no.: 917903


The printer has a chinese character set for printing
messages if the chinese language is set.

Included in delivery
Printer FMZ 5000 AP 1200 chinese

Not included in delivery


Installation material, power supply unit, front plate,
printer paper

Otherwise like part no.: 906263

Printer FMZ 5000 AP 1200 chinese Part no.: 917106


complete
Included in delivery
Printer FMZ 5000 AP 1200 chinese together with power
supply unit, installation material, cable, front plate 19” x 4U
with breakout for mounting the printer.

Not included in delivery


Printer paper

Otherwise like part no.: 906263

Printer FMZ 5000 AP 1200 hebrew Part no.: 917924


The printer has a hebrew character set for printing
messages if the hebrew language is set.

Included in delivery
Printer FMZ 5000 AP 1200 hebrew

Not included in delivery


Installation material, power supply unit, front plate,
printer paper
The contents of this publication are subject to modifications without notice. All rights reserved.

Otherwise like part no.: 906263

Printer FMZ 5000 AP 1200 hebrew Part no.: 917927


complete
Included in delivery
Printer FMZ 5000 AP 1200 hebrew together with power
supply unit, installation material, cable, front plate 19” x 4U
with breakout for mounting the printer.

Not included in delivery


301-480_001 / AI00_2015en

Printer paper

Otherwise like part no.: 906263

2/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 53
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 printer

Printer FMZ 5000 AP 1200 cyrillic Part no.: 917925


The printer has a cyrillic character set for printing
messages if the cyrillic language is set.

Included in delivery
Printer FMZ 5000 AP 1200 cyrillic

Not included in delivery


Installation material, power supply unit, front plate,
printer paper

Otherwise like part no.: 906263

Printer FMZ 5000 AP 1200 cyrillic Part no.: 917926


complete
Included in delivery
Printer FMZ 5000 AP 1200 cyrillic together with power
supply unit, installation material, cable, front plate 19” x 4U
with breakout for mounting the printer.

Not included in delivery


Printer paper

Otherwise like part no.: 906263

Mounting kit printer AP 1200 Part no.: 907344

Mounting kit includes all parts required for installation the


printer AP 1200 in a fire detection panel FMZ 5000 mod 12 or
mod XL.

Included in delivery
Power supply HMA30 SO5 Part no.: 904769
Front plate AP 1200  Part no.: 906231
Installation material, cable
The contents of this publication are subject to modifications without notice. All rights reserved.

Not included in delivery


Printer FMZ 5000 AP 1200
301-480_001 / AI00_2015en

3/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 54
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply PSU 2403 Part no.: 908878


The PSU 2403 is an independent power supply for
uninterrupted operation (UPS) with the following special
features:
- Temperature compensation (temperature sensor)
- Switch off in case of low battery.
For use as decentralized power supply of devices such as
smoke aspirating systems. Consumers can be connected
via 2 separately fused outputs. 3 dry contacts are available
for the messages operation, power failure, battery failure or
fault output 1 or output 2.
Temperature-controlled battery charging for 2 batteries 12 V
max. 26 Ah. Connected batteries are continuously monitored.
The output voltage is short-circuit proof.

Technical specifications Included in delivery


Complete power supply, ready for installation and operation.
Mains voltage 195 V - 264 V AC
Output voltage 24 V DC
Not included in delivery
Output current max. 3 A DC
spare fuses 3.15 A 908576
Battery capacity 2 x 12 V / 7 Ah to 26 Ah Batteries 12 V
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Approvals / marking
-25 °C to +85 °C
Storage temperature
(-13 °F to +185 °F)
G 212008 0333-CPD-075373-3
Relative humidity 20 to 95 %,
Weight 6 kg (13.2 lbs)
289 x 350 x 189 mm (WxHxD)
Dimensions
11.4 x 13.8 x 7.4 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-510_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 55
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply unit NT5100 3A Part no.: 908452


The power supply unit is used for the uninterrupted power
supply of the following:
• Fire alarm panels FMZ 5000 mod 4 / 12
• Other external devices with a rated operating
voltage of 24V DC
Temperature-controlled battery charging for 2 batteries 12 V
max. 26 Ah. Connected batteries are continuously monitored.
The output voltage is short-circuit proof.

Technical specifications Included in delivery


Power supply unit completely assembled and ready for
Mains voltage 115 V / 230 V ±15% AC
installation in the device on mounting rail.
Mains frequency 50 Hz - 60 Hz
Output voltage 21 V - 27,2 V DC Not included in delivery
Output current Imax b 3 A DC Spare fuse 3.15 A / 250 V 908576
Battery capacity 2 x 12 V / 7,2 Ah to 26 Ah
- 5°C to + 50 °C
Ambient temperature
(+23 °F to +122 °F)
Specification according to EN 54-4 A2:2007 Approvals / marking
Weight 0.8 kg (1.8 lbs)
G 209209 0333-CPR-075373
185 x 105 x 65 mm (WxHxD)
Dimensions
7.3 x 4.1 x 2.6 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-510_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 56
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply unit NT5100 8A Part no.: 908453


The power supply unit is used for the uninterrupted power
supply of the following:
• Fire alarm panels FMZ 5000 mod XL
• Other external devices with a rated operating
voltage of 24V DC
Temperature-controlled battery charging for 2 batteries 12 V
max. 85 Ah. Connected batteries are continuously monitored.
The output voltage is short-circuit proof.

Included in delivery
Technical specifications
Power supply unit completely assembled and ready for
Mains voltage 115 V / 230 V ±15% AC installation in the device on mounting rail.
Mains frequency 50 Hz - 60 Hz
Output voltage 21 V - 27,2 V DC Not included in delivery
Output current Imax b 8 A DC Spare fuse 6.3 A; 5x20 908577
Spare fuse 12.5 A; 5x20 908579
Battery capacity 2 x 12 V / 18 Ah bis 85 Ah
Cable set
-5 °C bis +65 °C
Ambient temperature
(23 °F to +149 °F)
Specification according to EN 54-4 A2:2007
Note
This power supply unit is only to be used in FMZ 5000 XL
Weight 2,2 kg (4.9 lbs) 21U, 31U, 40U due to reasons of temperature conditions.
226 x 182 x 78 mm (WxHxD)
Dimensions
8.9 x 7.2 x 3.1 inch (WxHxD)
Approvals / marking

G 210080 0333-CPD-075214
The contents of this publication are subject to modifications without notice. All rights reserved.
301-510_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 57
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply unit NT5100 12A Part no.: 908454


The power supply unit is used for the uninterrupted power
supply of the following:
• Fire alarm panels FMZ 5000 mod XL
• Other external devices with a rated operating
voltage of 24V DC
Temperature-controlled battery charging for 2 batteries 12 V
max. 115 Ah. Connected batteries are continuously monito-
red. The output voltage is short-circuit proof.

Included in delivery
Technical specifications
Power supply unit completely assembled and ready for
Mains voltage 115 V / 230 V ±15% AC installation in the device on mounting rail.
Mains frequency 50 Hz - 60 Hz
Output voltage 21 V - 27,2 V DC Not included in delivery
Output current Imax b 12 A DC Spare fuse 6.3 A; 5x20 908577
Spare fuse 12.5 A; 5x20 908579
Battery capacity 2 x 12 V / 18 Ah bis 115 Ah
Cable set
-5 °C bis +65 °C
Ambient temperature
(23 °F to +149 °F)
Specification according to EN 54-4 A2:2007
Note
This power supply unit is only to be used in FMZ 5000 XL
Weight 2,2 kg (4.9 lbs) 21U, 31U, 40U due to reasons of temperature conditions.
226 x 182 x 78 mm (WxHxD)
Dimensions
8.9 x 7.2 x 3.1 inch (WxHxD)
Approvals / marking

G 210081 0333-CPD-075215
The contents of this publication are subject to modifications without notice. All rights reserved.
301-510_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 58
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply unit NT5000 5A Part no.: 901037


The power supply unit is used for uninterrupted power supply
of the following:
- Fire alarm panels FMZ 5000 mod 12 / XL
- Other external devices
with a rated operating voltage of 24V DC
Temperature-controlled battery charging for 2 batteries 12 V
max. 40 Ah. Charging characteristics are adjustable for
different battery types.
Connected batteries are continuously monitored.
The output voltage is short-circuit proof.
Common fault indication as GND switching relay output.

Included in delivery
Power supply unit completely assembled and ready for
Technical specifications installation in the device on mounting rail.

Mains voltage 115 V / 230 V -15%, +10% AC


Not included in delivery
Mains frequency 50 Hz - 60 Hz Spare fuse 15 A 891423
Output voltage 21 V - 29 V DC
Output current Imax b 5 A DC Note
The power supply unit and the batteries must be selected
Battery capacity 2 x 12 V / 7.2 Ah bis 45 Ah
according to the table at the end of the chapter.
Ambient temperature -5 °C to +50 °C (-4 °F to +122 °F)
Specification according to EN 54-4:1997 + A1:2002 + A2:2006 Approvals / marking
Weight 1.3 kg (2.9 lbs)
G 204140 0786-CPD-20360
190 x 129 x 103 mm (WxHxD)
Dimensions
7.5 x 5.1 x 4.1 inch (WxHxD)

Power supply unit NT5000 15A Part no.: 901038


The power supply unit is used for uninterrupted power supply of
the following:
- Fire alarm panels FMZ 5000 XL
- Other external devices with a rated operating
voltage of 24V DC
Temperature-controlled battery charging for 2 batteries 12 V
max. 115 Ah. Charging characteristics are adjustable for
different battery types.
Connected batteries are continuously monitored.
The contents of this publication are subject to modifications without notice. All rights reserved.

The output voltage is short-circuit proof.


Common fault indication as GND switching relay output.

Included in delivery
Technical specifications Power supply unit completely assembled and ready for
Mains voltage 115 V / 230 V -15%, +10% AC installation in the device on mounting rail.

Mains frequency 50 Hz - 60 Hz Not included in delivery


Output voltage 21 V - 29 V DC Spare fuse 20 A 904021
Output current Imax b 15 A DC
Note
Battery capacity 2 x 12 V / 18 Ah bis 115 Ah The power supply unit and the batteries must be selected
301-510_005 / AI00_2015en

Ambient temperature -5 °C to +50 °C (-4 °F to +122 °F) according to the table at the end of the chapter.
Specification according to EN 54-4:1997 + A1:2002 + A2:2006 Approvals / marking
Weight 3.2 kg (7.1 lbs)
250 x 150 x 103 mm (WxHxD) G 204139 0786-CPD-20282
Dimensions
9.8 x 5.9 x 4.1 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 59
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 power supply units

Power supply unit HMA30 S05 Part no.: 904769


Power supply unit for a printer FMZ 5000 AP 1200.
The power supply unit is mounted on the DIN rail with
terminals for mains connection.

Included in delivery
Power supply unit completely assembled and ready for
installation in the device on mounting rail.

Not included in delivery


Installation material

Technical specifications
Mains voltage 90 V - 264 V AC / 50 - 400 Hz
Mains frequency 50 Hz - 60 Hz
Output voltage 5 V DC
Output current Imax 3 A DC
-0°C to +50 °C
Ambient temperature
(+32 °F to +122 °F)
Weight 0.4 kg (0.8 lbs)
35 x 113 x 70 mm (BxHxT)
Dimensions
1.4 x 4.4 x 2.7 inch (BxHxT)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-510_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 60
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 batteries

Battery 2.2 Ah Part no.: 236023

Technical specifications Included in delivery


Connection Blade terminal 4.8 mm (0.19 inch) 1 Battery 12V / 2.2 Ah
Weight 1.0 kg (2.2 lbs)
178 x 34 x 65 mm (WxHxD) Approvals / marking
Dimensions
7 x 1.3 x 2.6 inch (WxHxD)
G 107033

Battery 7.2 Ah Part no.: 902941

Technical specifications Included in delivery


Connection Blade terminal 4.8 mm (0.19 inch)
1 Battery 12V / 7.2 Ah

Weight 2.6 kg (5.7 lbs)


151 x 102 x 65 mm (WxHxD)
Approvals / marking
Dimensions
5.9 x 4 x 2.6 inch (WxHxD)
G 107034

Battery 12 Ah Part no.: 761677

Technical specifications Included in delivery


Connection Blade terminal 4.8 mm (0.19 inch) 1 Battery 12V / 12 Ah

Weight 4.6 kg (10.1 lbs)


151 x 98 x 99 mm (WxHxD)
Approvals / marking
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

5.9 x 3.9 x 3.9 inch (WxHxD)


G 114091

Battery 18 Ah Part no.: 756859

Technical specifications Included in delivery


(5 mm (0.2 inch) hole) blade 1 Battery 12V / 18 Ah
Connection
terminal 6.5 mm (0.26 inch)
Weight 6.4 kg (14.1 lbs) Approvals / marking
181 x 167 x 76 mm (WxHxD)
301-521_001 / AI01_2016en

Dimensions
7.1 x 6.6 x 3 inch (WxHxD) G 114074

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 61
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 batteries

Battery 26 Ah Part no.: 132721

Technical specifications Included in delivery


(5 mm (0.2 inch) hole) blade 1 Battery 12V / 26 Ah
Connection
terminal 6.3 mm (0.25 inch)
Weight 9.6 kg (21.2 lbs) Approvals / marking
166 x 125 x 175 mm (WxHxD)
Dimensions
6.5 x 4.9 x 6.9 inch (WxHxD) G 107038

Battery 45 Ah Part no.: 832386

Technical specifications Included in delivery


(5 mm (0.2 inch) hole) blade 1 Battery 12V / 45 Ah
Connection
terminal 6.3 mm (0.25 inch)
Weight 14.2 kg (31.3 lbs) Approvals / marking
197 x 172 x 166 mm (WxHxD)
Dimensions
7.8 x 6.8 x 6.5 inch (WxHxD) G 107039

Battery 65 Ah Part no.: 794921

Technical specifications Included in delivery


(6 mm (0.24 inch) hole) blade 1 Battery 12V / 65 Ah
Connection
terminal 6.3 mm (0.25 inch)
Weight 23.6 kg (52 lbs) Approvals / marking
350 x 174 x 166 mm (WxHxD)
Dimensions
13.8 x 6.9 x 6.5 inch (WxHxD) G 107040

Battery 85 Ah Part no.: 801758

Technical specifications Included in delivery


(Conical pin) blade terminal 1 Battery 12V / 85 Ah
Connection
6.3 mm (0.25 inch)
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 31.0 kg (68.3 lbs) Approvals / marking


330 x 171 x 232 mm (WxHxD)
Dimensions
13 x 6.7 x 9.1 inch (WxHxD) G 190046

Battery 115 Ah Part no.: 800775

Technical specifications Included in delivery


(Conical pin) blade terminal 1 Battery 12V / 115 Ah
Connection
6.3 mm (0.25 inch)
301-521_001 / AI01_2016en

Weight 40.0 kg (88.2 lbs)


267 x 284 x 230 mm (WxHxD)
Dimensions
10.5 x 11.2 x 9.61 inch (WxHxD)

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 62
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 fire alarm panel accessories

Ribbon cable 10 wire Part no.: 853805

Technical specifications
Weight 18 g/m (0.04 lbs/m)

Quantity unit for orders = metres

Ribbon cable, round, shielded 20 wire Part no.: 800315

Technical specifications
Weight 118 g/m (0.3 lbs/m)
Quantity unit for orders = metres

Ribbon cable shielded 20 wire Part no.: 784157

Technical specifications
Weight 43 g/m (0.09 lbs/m)

Quantity unit for orders = metres

Female connector 2 x 5 pol. Part no.: 796759

Technical specifications
Weight 1 g (0.002 lbs)

Female connector 2 x 10 pol. Part no.: 784170

Technical specifications
Weight 3 g (0.007 lbs)

Cable set FMZ 5000 mod S Relay card Part no.: 913673
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Weight 6 g (0.01 lbs)

Included in delivery
1 Cable set complete with socket
301-590_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 63
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 fire alarm panel accessories

Key set BMA control panel Part no.: 917687


Key set for all FMZ 5000 fire detection and alarm control
panels and connected peripheral equipment.

Product features
• Allows access to Minimax fire detection and alarm
control panels of the FMZ 5000 series
• Allows access to manual call point for indoor applications
• Allows access to „Zonecheck“

Included in delivery
Key for:
1 DMX3000
Technical specifications 1 FMZ 5000 mod XL / mod 12 / mod S
Weight 80 g (0.17 lbs) 1 FMZ 5000 mod XL, pivoting frames
1 FMZ 5000 mod 12, internal door
1 FMZ 5000 mod S, front panel
1 Zonecheck and
1 Key ring 16 mm (0.63 inch)
The contents of this publication are subject to modifications without notice. All rights reserved.
301-590_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 64
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 5000 fire alarm panel accessories

Fire protection housing F 30 Part no.: 917789


FMZ 5000 mod 12 The fire protection housing is intended for use in areas
where according to MLAR (chapter 3.2.2) the FMZ 5000
(electric distributor) must be separated from passageways,
staircases as well as outdoor exits and the use of distributors
for electrical circuit systems with functional integrity for
30 minutes (cable routing E 30) is required.

Product features Included in delivery


• Tailored fire protection housing for FMZ 5000 mod 12 Fire protection housing F 30
• Enclosure with integrated passive airing system in Mounting hardware: screws and dowels
door and enclosure top
• Certified protection housing in accordance to DIN 4102-2 Not included in delivery
• Panel specific cable glance grid through incombustible Lock cylinder fire protection housing F 30 918146
basic fire protection plate according to EN 13501-A2
• 4 integrated mounting points and specific Note
FMZ 5000 mod 12 mounting plate The fire protection housing F 30 has a left-hinged door
stop with hidden steal hinges for free access to the fire alarm
and control panel during commissioning and maintenance.
Technical specifications The fire protection housing can be opened using a swivelling
lever in which a DIN half cylinder can be retrofitted.
functional integrity 30 minutes
- according to E 30
If access level 1 according to DIN 54-2 (without specific
fire resistance 30 minutes procedures) is required, then the lock cylinder fire protection
Specifications housing F 30 (Part no. 918146) must be used instead of
- according to F 30
fire load insulation 30 minutes the standard keys provided.
- according to I 30 Additional installation of fire detectors inside the enclosure
based on ABZ-Nr. Z-86.1-5 is possible.
Source and disposition
based on ABZ-Nr. Z-86.1-10
Enclosure composite material
outside: 978 x 828 x 395 mm (WxHxD)
38.50 x 32.59 x 15.55 inch (WxHxD)
Dimensions
inside: 800 x 650 x 300 mm (WxHxD)
31.96 x 25.59 x 11.81 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 54, protection class II


Colour similar to RAL 7035
Weight approx. 105 kg ( 231.48 lbs)
Wall-mounted installation
Mounting
(Fastening with rear panel)

Fire protection housing F 30 Part no.: 917788


FMZ 5000 mod 4

Technical specifications
301-590_002 / AI01_2016en

Otherwise like part no.: 917789


outside: 728 x 728 x 345 mm (WxHxD)
28.66 x 28.66 x 13.58 inch (WxHxD)
Dimensions
inside: 550 x 550 x 250 mm (WxHxD)
21.65 x 21.65 x 9.84 inch (WxHxD)
Weight approx. 71 kg ( 156.52 lbs)
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 65
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 4100 cards

Relay expansion card 8 Part no.: 802587


Relay expansion card for use in all variants of the FMZ 5000
control panel. Contains 8 relays with freely configurable
function. Two changeover contacts per relay are connected
to the connecting terminal. A 10-pin ribbon cable or conductor
cores can be used to connect the card.
The relays are actuated by a 0 V signal via the ribbon cable
or the wires to the soldering terminals.

Application Product features


• Each relay can be activated separately For further notification of any state messages or triggering
• Activation of a relay is displayed by its own LED of unmonitored loads.
Card can be used per relay module in the FMZ 5000. In the
• Wires can also be connected the soldering
FMZ 5000 mod S card can be connected to the mainboard.
terminals for direct activation of the relays
• All settings are implemented with the configuration
programme of the control unit in which the card Included in delivery
is inserted Card with mounting brackets for mounting on a mounting rail
• No adjustments are necessary
Not included in delivery
Relay SDS 24 V DC  796085
Ribbon cable 10-wire (bulk stock)  853805
Technical specifications Female connector 2 x 5 pin.  796759
Mains voltage 21 V - 29 V DC Cable set FMZ 5000 mod S Relay card 913673
Quiescent current 0 mA DC
No. of relays 8 Note
Current per relay 8.5 mA (relay activated) The relay contacts are not suitable for switching 230 V AC
mains voltage.
Contact load 4 A / 60 V AC, 3 A / 30 V DC
Contact rating max. 90 W / 1000 VA
Approvals / marking
2 changeover contacts,
Contacts per relay
potential-free
Terminal cross-section max. 4 mm2 (AWG 13)
-5 °C to +40 °C
Ambient temperature
The contents of this publication are subject to modifications without notice. All rights reserved.

(+23 °F to +104 °F)


Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Mounting rail 35 DIN 46277,
Enclosure
top hat profile
Weight 166 g (0.36 lbs)
140 x 68 x 48 mm (WxLxD)
Dimensions
5.5 x 2.7 x 1.9 inch (WxLxD
301-120_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 66
Product Sheet | Detecon

Fire alarm and extinguishing control panels


FMZ 4100 cards

Relay expansion card 8TQ Part no.: 800843


Relay expansion card for use in all variants of the FMZ 5000
control panel. Contains 8 relays with freely configurable
function. One changeover contact per relays is connected
to the connecting terminal. The relay are actuated via a
0 V signal via the ribbon cable or the wires to the soldering
terminals.

Application Product features


• Each relay can be activated separately For further notification of any state messages or triggering
• Activation of a relay is displayed by its own LED of unmonitored loads.
Card can be used per relay module in the FMZ 5000. In the
• Wires can also be connected the soldering FMZ 5000 mod S card can be connected to the mainboard.
terminals for direct activation of the relays
• All settings are implemented with the configuration
programme of the control unit in which the card Included in delivery
is inserted Card with mounting brackets for mounting on a mounting rail
• No adjustments are necessary
Not included in delivery
Ribbon cable 10-wire (bulk stock)  853805
Female connector 2 x 5 pol.  796759
Technical specifications Cable set FMZ 5000 mod S Relaycard  913673
Mains voltage 21 V - 29 V DC
Quiescent current 0 mA DC Note
No. of relays 8 The relay contacts are not suitable for switching 230 V AC
mains voltage
Current per relay 6 mA (relay activated)
Contact load 0.5 A / 60 V AC, 1 A / 30 V DC
Approvals / marking
Contact rating max. 30 W / 62.5 VA
1 changeover contacts,
Contacts per relay
potential-free
Terminal cross-section max. 4 mm2 (AWG 13)
-5 °C to +40 °C
Ambient temperature
The contents of this publication are subject to modifications without notice. All rights reserved.

(+23 °F to +104 °F)


Relative humidity max. 95 %
(IEC 721-3-3) no condensation
Mounting rail 35 DIN 46277,
Enclosure
top hat profile
Weight 96 g (0.21 lbs)
70 x 68 x 48 mm (WxLxD)
Dimensions
2.8 x 2.7 x 1.9 inch (WxLxD)
301-120_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 67
Product Sheet | Detecon

Fire brigade and system accessories


Fire brigade control panels

Fire brigade control panel FBF 2001 Part no.: 908147


Fire brigade control panel for Minimax FMZ 5000 fire alarm
panels in accordance with DIN 14661. The front door
can be locked with a case lock with profile half cylinder in
accordance with DIN 18252.

Connection / mounting
The control panel is connected directly to the remote
transmission unit module using a 20-pin ribbon cable.
For this the ADP-FBF-MX connector card needs to be
inserted in the FBF. Alternatively, for connection using
cable wires, the FLK20 adapter (from Phoenix Contact)
can be used in the fire alarm panel.

Included in delivery
Technical specifications Fire brigade control panel completely assembled and
Operating voltage 10 V - 30 V DC ready for connection to the fire alarm panel, including
Quiescent current consump- ADP-FBF-MX connector card.
approx. 10 mA
tion (24 V)
Alarm current consumption
approx. 75 mA Not included in delivery
(24 V) Mounting hardware: screws and dowels
0 °C to +50 °C Ribbon connecting cable, round  800315
Operating temperature
(+32 °F to +122 °F) Remote transmission unit module 901969
IP rating IP 30 Profile half cylinder
Enclosure colour RAL 7032
Weight 3.4 kg (7.5 lbs) Approvals / marking
255 x 185 x 58 mm (WxHxD)
Dimensions
10 x 7.3 x 2.3 inch (WxHxD) G 299034

Fire brigade control panel FBF2003 Part no.: 910530


serial mod S Fire brigade control panel for Minimax FMZ 5000 mod S
fire alarm panels in accordance with DIN 14661.
The front door can be locked with a case lock with profile
half cylinder in accordance with DIN 18252

Connection / mounting
Connection takes place via the RS422 interface of
the FMZ 5000 mod S card‘s fire alarm peripheral.
The contents of this publication are subject to modifications without notice. All rights reserved.

This card is not included in the basic version of the unit.

Included in delivery
Fire alarm control panel, completely ready for assembly
Technical specifications to be connected to the fire alarm control unit.
Operating voltage 10 V - 42 V DC
Quiescent current consump- Not included in delivery
approx. 15 mA
tion (24 V) Mounting hardware: screws and dowels
Alarm current consumption FMZ 5000 mod S fire accessory 909365
approx. 30 mA
(24 V)
0 °C to +50 °C
Operating temperature Approvals / marking
(+32 °F to +122 °F)
302-110_001 / AI00_2015en

IP rating IP 30
G 205053
Enclosure colour RAL 7032
Weight 3.6 kg (7.9 lbs)
255 x 185 x 58 mm (WxHxD)
Dimensions
10 x 7.3 x 2.3 inch (WxHxD)
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 1
Product Sheet | Detecon

Fire brigade and system accessories


Fire brigade display panel

Fire brigade display panel FAT 2002 Part no.: 908148


Fire brigade display panel for Minimax FMZ 5000 fire alarm
panels in accordance with DIN 14662 for indication of fire
alarm and fault signals as initial information for the fire
brigade. Text display with 4 rows of 20 characters each.
The text sent from the message frame is used, which is
why no configuration is required. Two signals can be
displayed at the same time.

Connection / mounting
Connection is established via the RS232 or RS422 interface
on the SIO1 or SIO3 module. The Mx2 data protocol is used.

Included in delivery
Technical specifications Fire brigade display panel completely assembled
and ready for connection to the fire alarm panel.
Operating voltage 10 V - 30 V DC
Interface module with Minimax data protocol.
Quiescent current Specify RS232 or RS422 interface when ordering.
approx. 50 mA
consumption (24 V)
Alarm current consumption
(24 V)
max. approx. 170 mA Not included in delivery
Mounting hardware: screws and dowels
0 °C bis + 50 °C
Operating temperature Connecting cable
(+32 °F to +122 °F)
Profile half cylinder
IP rating IP 30
Enclosure colour RAL 7032 Approvals / marking
Weight 3.6 kg (7.9 lbs)
255 x 185 x 58 mm (WxHxD) G 203086
Dimensions
10 x 7.3 x 2.3 inch (WxHxD)

Fire brigade display panel FAT 2002 Part no.: 908149


Fire brigade display panel with redundant data connection
to the fire alarm panel as a source of initial information for
the fire brigade.

Connection / mounting
Connection is established via the RS232 interface on the
SIO1 or SIO3 module, to an ADP-NB adapter card in the fire
The contents of this publication are subject to modifications without notice. All rights reserved.

alarm panel. The FAT 2002 re is connected to the ADP-NB


via 2 data lines. The Mx2 data protocol is used.

Approvals / marking

G 203086
302-120_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 2
Product Sheet | Detecon

Fire brigade and system accessories


Fire brigade display panel

FAT 3000 mod S Part no.: 910526


Fire brigade display panel for Minimax fire extinguishing and
detection control panels FMZ 5000 mod S according to DIN
14662 to display fire alarm and fault
messages as initial information for the fire brigade, plain
text display with 4 lines and 20 characters per line.
Two messages are simultaneously displayable.

Connection / mounting
The connection occurs via the RS422 interface of the
card FMZ5000 mod S fire brigade peripheral equipment.
This card is not included in the basic configuration of the fire
detection control panel.

Technical specifications Included in delivery


Fire brigade display panel complete,
Operating voltage 10 V - 42 V DC
ready for connection to the fire detection control panel.
Quiescent current
approx. 50 mA
consumption (24 V)
Alarm current consumption
Not included in delivery
approx. 80 mA Accessories FMZ 5000 mod S fire brigade 909365
(24 V)
Connection cable
0 °C bis + 50 °C
Operating temperature Fastening material, screws and dowels
(+32 °F to +122 °F)
IP rating IP 30
Approvals / marking
Enclosure colour RAL 7032
Weight 3.6 kg (7.9 lbs)
G 205076
255 x 185 x 58 mm (WxHxD)
Dimensions
10 x 7.3 x 2.3 inch (WxHxD)

FAT 3000 mod S re Part no.: 910529


Fire brigade display panel with redundant
data connection to the fire detection control panel as initial
information for the fire brigade.

Connection / mounting
The connection occurs via the RS422 interface of the card
FMZ 5000 S fire brigade peripheral equipment.
The contents of this publication are subject to modifications without notice. All rights reserved.

This card is not included in the basic configuration of the


fire detection control panel. Provision of the redundant data
interface requires installation of an ADP-N3E.U adapter board
in the fire detection control panel.

Included in delivery
Fire brigade display panel complete, ready for connection to
the fire detection control panel, including ADP-N3E-U adapter
board.

Approvals / marking
302-120_002 / AI00_2015en

G 205076

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 3
Product Sheet | Detecon

Fire brigade and system accessories


Graphic panel

LMT-4 LED graphic panel Part no.: 910169


LED graphic panel in an aluminium housing with hinged
grid plate and transparent front window for a user-defined
layout that can be replaced at any time, e.g.. diagram, plot
etc. The panel allows the placement of LEDs that light up the
inserted plan at desired points, plus sensor buttons which
trigger switch functions at any place in the plan by tapping
through the front plate as on a touch panel.

Product features
• For DIN A4 insert with lock
• extensive accessories and various interfaces
and connection- and distribution boards with
parallel or serial signal inputs

Technical specifications
Included in delivery
Output voltage 24 V DC
1 LMT-4 LED graphic panel without attachment material
Housing material Aluminium
Protection class IP 54
Not included in delivery
Weight 1850 g (4.1 lbs) Red LED diodes for LMT panel  910172
359 x 272 x 46 mm (WxHxD) Green LED diodes for LMT panel  910173
Dimensions
14.13 x 10.7 x 1.8 inch (WxHxD) Yellow LED diodes for LMT panel  910174
8 LED adapter card for LMT panel 910175
Capacitive butten for LMT panel 910176
LED distribution board VK-16 910177

LMT-3 LED graphic panel Part no.: 910171


LED graphic panel in an aluminium housing with hinged
grid plate and transparent front window for a user-defined
layout in between that can be replaced at any time, e.g.
diagram, plot etc. The panel allows the placement of LEDs
that light up the inserted plan at desired points, plus sensor
buttons which trigger switch functions at any place in the
plan by tapping through the front plate as on a touch panel.

Product features
• For DIN A3 insert with lock
• Extensive accessories and various interfaces
The contents of this publication are subject to modifications without notice. All rights reserved.

and connection- and distribution boards with


parallel or serial signal inputs
Technical specifications
Output voltage 24 V DC Included in delivery
1 LMT-3 LED graphic panel without attachment material
Housing material Aluminium
Protection class IP 54
Not included in delivery
Weight 3050 g (6.7 lbs)
Red LED diodes for LMT panel  910172
482 x 359 x 46 mm (WxHxD) Green LED diodes for LMT panel  910173
Dimensions
19 x 14.1 x 1.8 inch (WxHxD) Yellow LED diodes for LMT panel  910174
8 LED adapter card for LMT panel 910175
302-520_001 / AI00_2015en

Capacitive butten for LMT panel 910176


LED distribution board VK-16 910177

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 4
Product Sheet | Detecon

Fire brigade and system accessories


Graphic panel

Red LED diodes for LMT panel Part no.: 910172


Super bright LED prefabricated with flexible 800 mm
connecting cable and reverse-polarity protected sockets
for safe attachment to distributor-, adapter- or system-
specific control modules.

Included in delivery
8 LM LED red
Plastic spacer

Technical specifications
Weight 45 g (0.1 lbs)

Green LED diodes for LMT panel Part no.: 910173


8 LM LED green

Otherwise as for part no. 910172

Yellow LED diodes for LMT panel Part no.: 910174


8 LM LED yellow

Otherwise as for part no. 910172

8 LED adapter card for LMT panel Part no.: 910175


Universal adapter board for 8 LEDs, with 8 pre-resistors.

Included in delivery
1 LED adapter card for LMT panel for 8 LEDs
Plastic spacers

Technical specifications
Signal voltage 24 V DC
The contents of this publication are subject to modifications without notice. All rights reserved.

Signal current 10 mA
Weight 31 g (0.1 lbs)
113 x 37 x 15 mm (WxHxD)
Dimensions
4.5 x 1.5 x 0.6 inch (WxHxD)
302-520_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 5
Product Sheet | Detecon

Fire brigade and system accessories


Graphic panel

Capacitive button for LMT panel Part no.: 910176


Compact capacitive sensor button as control element
for plugging into the 5 mm holes of the LM breadboard.
When approached by a finger, it switches the optocoupler
output through the front panel together with an optical
status display. It performs self-calibration to suppress
environmental influences.

Included in delivery
1 Capacitive button for LMT panel
Plastic spacer
Technical specifications
Operating voltage 12 V - 24 V DC
Current consumption 6 mA
Optocoupler output max. 24 V DC / 18 mA
Weight 21 g (0.05 lbs)
21 x 21 x 12 mm (WxHxD)
Dimensions
0.82 x 0.82 x 0.47 inch (WxHxD)

LED distribution board VK-16 Part no.: 910177


LED distribution board for 16 signal inputs and 16 x 2 LED
outputs on polarized pin connectors, with a slot for the
connection of a lamp test button. Input signals either
positive or negative through bidirectional optocoupler inputs.

Included in delivery
1 LED distribution board VK-16
Plastic spacer
Technical specifications
Operating voltage 12 V - 24 V DC
Quiescent current
4 mA
consumption
Current consumption per
10 mA
activated output
Max. current consumption 170 mA
Signal level min. 5 V
The contents of this publication are subject to modifications without notice. All rights reserved.

optocoupler inputs max. 24 V


Weight 107 g (0.24 lbs)
200 x 20 x 78 mm (WxHxD)
Dimensions
7.87 x 0.78 x 3.07 inch (WxHxD)
302-520_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 3 - 6
Product Sheet | Detecon

Manual call points


DMX indoor application

Overview indoor application

Application Accessories Replacement

(further approval on catalogue

Detector element (inlay) DMX

Detector element (inlay) DMX


Special labeling for outside

Board DMX3000, LED ext.


Board DMX3000 (907764)
Non-Latching contact (T)
Application

Weatherproof enclosure

Weatherproof enclosure

Weatherproof enclosure

Weatherproof enclosure

Board DMX95-I (916383)


Board DMX3000, 2GRU

Board DMX95 (907942)


Symbol LED (904450)

Board DMX3000, LED


Short circuit isolator

Latching contact (R)

Catalogue Chapter
Individual labeling
Approvals/ Norms
Accessories

Conventional (G)

Symbol (904449)
Addressable (A)

yellow (903779)

French labeling
green (903791)
blue (903780)
Silicone-free

red (903792)
Replacement

Alarm-LED

(907765)

(907766)

(907728)
IP rating

Ex Zone

page)

sign
Manual Call Points

903639
VdS
DMX3000 IP 42 --- ---
EN 54-11
--- R G --- X --- --- --- X1 X
1
--- X --- X --- --- --- --- --- 4-12
Manual Call Point, red

888791
DMX3000 Manual Call Point IP 42 --- --- --- --- R G --- X --- --- --- X1 X1 --- X --- X --- --- --- --- --- 4-14
fire brigade, red

904463
VdS
DMX3000 LED IP 42 --- --- X R G --- X --- --- --- --- --- --- --- X --- X --- --- --- --- 4-17
EN 54-11
Manual Call Point, red

904463
VdS
DMX2000 LED IP 42 --- --- X R G --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4-20
EN 54-11
Manual Call Point, red

902895
VdS
DMX95 IP 42 --- --- X R A --- X --- --- --- --- --- --- --- X --- --- --- --- X --- 4-3
EN 54-11
Manual Call Point, red

915745
VdS
DMX95-I IP 43 X --- X R A --- X --- --- --- --- --- --- --- X --- --- --- --- --- X 4-7
EN 54-11
Manual Call Point, red

904474
DMX95 Manual Call Point IP 42 --- --- --- X R A --- X --- --- --- --- --- --- --- X --- --- --- --- X --- 4-5
fire brigade, red

915746
DMX95-I Manual Call Point IP 43 X --- --- X R A --- X --- --- --- --- --- --- --- X --- --- --- --- --- X 4-9
fire brigade, red

912579
KAX DIS 908r IP 45 X --- EN 54-11 X R A --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4-11
Manual Call Point, red

903767 VdS
1
DMX3000 Ex IP 42 --- EN 54-11 --- R G --- X --- --- --- X1 X
1
--- X --- --- --- --- --- --- --- 4-24
22 ATEX
Manual Call Point, red

888845
VdS
DMX3000 IP 42 --- ---
EN 12094-3
--- R G --- --- X --- --- X1 X
1
--- X --- X --- --- --- --- --- 4-13
Manual Release, yellow

801001
VdS
DMX3000 SF IP 42 --- --- --- R G X --- X --- --- --- --- --- --- --- --- --- --- --- --- --- 4-15
EN 12094-3
Manual Release, yellow

904466
VdS
DMX3000 LED IP 42 --- --- X R G --- --- X --- --- --- --- --- --- X --- X --- --- --- --- 4-18
EN 12094-3
Manual Release, yellow
The contents of this publication are subject to modifications without notice. All rights reserved.

920844
VdS
DMX2000 LED IP 42 --- --- X R G --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4-21
EN 12094-3
Handauslösung, gelb

904477
VdS
DMX95 IP 42 --- --- X R A --- --- X --- --- --- --- --- --- X --- --- --- --- X --- 4-4
EN 12094-3
Manual Release, yellow

915747
VdS
DMX95-I IP 43 X --- X R A --- --- X --- --- --- --- --- --- X --- --- --- --- --- X 4-8
EN 12094-3
Manual Release, yellow

903770 VdS
1
DMX3000 Ex IP 42 --- EN 12094-3 --- R G --- --- X --- --- X1 X
1
--- X --- --- --- --- --- --- --- 4-25
22 ATEX
Manual Release, yellow

888821
VdS
DMX3000 IP 42 --- ---
EN 12094-3
--- T G --- --- --- X --- X1 X
1
--- X --- X --- --- --- --- --- 4-13
Emergency Button, blue
310-010_001 / AI01_2016en

801003
VdS
DMX3000 SF IP 42 --- --- --- T G X --- --- X --- --- --- --- --- --- --- --- --- --- --- --- 4-16
EN 12094-3
Emergency Button, blue

904465
VdS
DMX3000 LED IP 42 --- --- --- T G --- --- --- X --- --- --- --- --- X --- X --- --- --- --- 4-18
EN 12094-3
Emergency Button, blue

905352
DMX95 IP 42 --- --- --- X R A --- --- --- X --- --- --- --- --- X --- --- --- --- X --- 4-4
Internal Alarm, blue
1/2
903769 VdS
DMX3000 Ex © Viking GmbH &IPCo.
42 KG
--- | Industriestr.
1
EN 12094-3 10/12
--- T| D-23843
G --- Bad---Oldesloe
--- |X www.viking-emea.com
--- X1 X1 --- | X Chapter
--- 4
--- - 1 --- --- --- --- --- 4-25
22 ATEX
Emergency Button, blue

915749
DMX95-I IP 43 X --- --- X R A --- --- --- X --- --- --- --- --- X --- --- --- --- --- X 4-8
Internal Alarm, blue
801001
VdS
DMX3000 SF IP 42 --- --- --- R G X --- X --- --- --- --- --- --- --- --- --- --- --- --- --- 4-15
EN 12094-3
Manual Release, yellow

904466
DMX3000 LED
Product SheetIP|42Detecon
--- ---
VdS
X R G --- --- X --- --- --- --- --- --- X --- X --- --- --- --- 4-18
EN 12094-3
Manual Release, yellow

920844
VdS
DMX2000 LED IP 42 --- --- X R G --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4-21
EN 12094-3
Manual call points
Handauslösung, gelb

904477
VdS
DMX
DMX95
indoor application
Manual Release, yellow
IP 42 --- ---
EN 12094-3
X R A --- --- X --- --- --- --- --- --- X --- --- --- --- X --- 4-4

915747
VdS
Overview
DMX95-I
Manual Release, yellow
indoor application
IP 43 X ---
EN 12094-3
X R A --- --- X --- --- --- --- --- --- X --- --- --- --- --- X 4-8

903770 VdS
1
DMX3000 Ex IP 42 --- EN 12094-3 --- R G --- --- X --- --- X1 X
1
--- X --- --- --- --- --- --- --- 4-25
22 ATEX
Manual Release, yellow Application Accessories Replacement
888821

(further approval on catalogue

Detector element (inlay) DMX

Detector element (inlay) DMX


Special labeling for outside
VdS
X1 1

Board DMX3000, LED ext.


Board DMX3000 (907764)
DMX3000 IP 42 --- --- --- T G --- --- --- X --- --- X --- X --- --- --- --- --- 4-13

Non-Latching contact (T)


Application X

Weatherproof enclosure

Weatherproof enclosure

Weatherproof enclosure

Weatherproof enclosure

Board DMX95-I (916383)


Board DMX3000, 2GRU

Board DMX95 (907942)


EN 12094-3

Symbol LED (904450)

Board DMX3000, LED


Short circuit isolator

Latching contact (R)


Emergency Button, blue

Catalogue Chapter
Individual labeling
Approvals/ Norms
Accessories

Conventional (G)

Symbol (904449)
Addressable (A)

yellow (903779)

French labeling
green (903791)
blue (903780)
Silicone-free

red (903792)
Replacement

Alarm-LED

(907765)

(907766)
801003

(907728)
IP rating

Ex Zone

VdS

page)

sign
DMX3000 SF IP 42 --- --- --- T G X --- --- X --- --- --- --- --- --- --- --- --- --- --- --- 4-16
EN 12094-3
Emergency Button, blue

904465
VdS
DMX3000Call
Manual LED Points IP 42 --- --- --- T G --- --- --- X --- --- --- --- --- X --- X --- --- --- --- 4-18
EN 12094-3
Emergency Button, blue

905352
903639
DMX95 IP 42
42 --- --- VdS
--- X R A --- --- --- X --- ---1 ---1 --- --- X --- --- --- --- X --- 4-4
DMX3000 IP --- --- --- R G --- X --- --- --- X X --- X --- X --- --- --- --- --- 4-12
EN 54-11
InternalCall
Manual Alarm, blue
Point, red

903769
888791 VdS
1
DMX3000 Manual
DMX3000 Ex Call Point IP 42
IP 42 ---
--- --- EN 12094-3
--- ---
--- T
R G
G ---
--- ---
X ---
--- X
--- ---
--- X11
X X1
X
1
---
--- X
X ---
--- ---
X ---
--- ---
--- ---
--- ---
--- ---
--- 4-25
4-14
22 ATEX
Emergency
fire brigade, Button,
red blue

915749
904463
DMX95-I LED IP 42
43 X --- VdS
--- X R A --- --- --- X --- --- --- --- --- X --- --- --- --- --- X 4-8
DMX3000 IP --- --- X R G --- X --- --- --- --- --- --- --- X --- X --- --- --- --- 4-17
EN 54-11
Internal Call
Manual Alarm, bluered
Point,

888810
904463 VdS
VdS
DMX3000 LED
DMX2000 IP 42
IP 42 ---
--- ---
--- ---
X T
R G
G ---
--- ---
--- ---
--- ---
--- X
--- ---
--- ---
--- ---
--- X
--- ---
--- X
--- ---
--- ---
--- ---
--- ---
--- ---
--- 4-13
4-20
EN
EN12094-3
54-11
2nd Release,
Manual greenred
Call Point,

904464
902895 VdS
VdS
DMX3000 LED
DMX95 IP 42
IP 42 ---
--- ---
--- X
X T
R G
A ---
--- ---
X ---
--- ---
--- X
--- ---
--- ---
--- ---
--- ---
--- X
X ---
--- X
--- ---
--- ---
--- ---
X ---
--- 4-18
4-3
EN
EN12094-3
54-11
2nd Release,
Manual greenred
Call Point,

904475
915745
DMX95 IP 43
42 --- --- VdS
--- X T A --- --- --- --- X --- --- --- --- X --- --- --- --- X --- 4-4
DMX95-I IP X --- X R A --- X --- --- --- --- --- --- --- X --- --- --- --- --- X 4-7
EN 54-11
2nd Release,
Manual greenred
Call Point,

915748
904474
DMX95-IManual Call Point
DMX95 IP 42
IP 43 X
--- ---
--- ---
--- X
X T
R A
A ---
--- ---
X ---
--- ---
--- X
--- ---
--- ---
--- ---
--- ---
--- X
X ---
--- ---
--- ---
--- ---
--- ---
X X
--- 4-8
4-5
2ndbrigade,
fire Release,red
green

903768
915746 VdS
1
DMX3000Manual
DMX95-I Ex Call Point IP 43
IP 42 ---
X --- EN 12094-3
--- ---
X T
R G
A ---
--- ---
X ---
--- ---
--- X
--- ---
--- ---
--- ---
--- X
--- ---
X ---
--- ---
--- ---
--- ---
--- ---
--- ---
X 4-25
4-9
22 ATEX
2ndbrigade,
fire Release,red
green

903246
912579
2 2 2 2 2 1,2 1,2 2 2 2 2 2 2
DMX3000
KAX DIS 908r IP 45
IP 42 ---
X ---
--- EN X
54-11 AA
X RR/ T G
A AA
--- X
--- X
--- X
--- X
--- X--- X--- X
--- X
--- X
--- X
--- X
--- X
--- X
--- ---
--- ---
--- 4-19
4-11
Manual Call
Manual Call Point,
Point, red
variable

904478
903767 VdS
DMX95 Ex IP 42
42 --- 1
--- 2
AA RR/ T A AA 2 2 2 2
---1 ---1 X --- X --- --- --- --- 2
--- 4-6
DMX3000 IP --- EN X
54-11 --- G --- X
X X
--- X
--- X
--- X X --- X --- --- --- --- --- X
--- --- 4-24
Manual Call
Call Point,
Point, red
variable 22 ATEX
Manual

915750
888845
DMX95-I IP 42
43 X --- VdS
X2 AA RR/ T A AA 2 2 2 2
---1 ---1 X --- X --- --- --- --- --- X 4-10
DMX3000 IP --- --- --- G --- X
--- X
X X
--- X
--- X X --- X --- X --- --- --- --- --- 4-13
EN 12094-3
Manual Release,
Manual Call Point,yellow
variable

904152
801001 1 ATEX
VdS 2 2 2 2 1 1
DMX3000 SF
DMX3000 Ex IP 42
IP 42 ---
--- --- ---
--- RR/ T G
G AA
X X
--- X
X X
--- X
--- X
--- X
--- X
--- X
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- 4-26
4-15
22 X2
EN 12094-3
Manual Release,
Manual Call Point,yellow
variable

904466
VdS
DMX3000 LED IP 42 --- --- X R G --- --- X --- --- --- --- --- --- X --- X --- --- --- --- 4-18
X1 = Manual Call Point is perhaps not EN 12094-3
Manual Release, yellow
approval compliant
The contents of this publication are subject to modifications without notice. All rights reserved.

920844
X2 = Depending on the variable type of VdS
DMX2000
detector LED IP 42 --- --- X R G --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 4-21
EN 12094-3
Handauslösung, gelb

AA = On request
904477
VdS
DMX95 IP 42 --- --- X R A --- --- X --- --- --- --- --- --- X --- --- --- --- X --- 4-4
EN 12094-3
Manual Release, yellow

915747
VdS
DMX95-I IP 43 X --- X R A --- --- X --- --- --- --- --- --- X --- --- --- --- --- X 4-8
EN 12094-3
Manual Release, yellow

903770 VdS
1
DMX3000 Ex IP 42 --- EN 12094-3 --- R G --- --- X --- --- X1 X
1
--- X --- --- --- --- --- --- --- 4-25
22 ATEX
Manual Release, yellow

888821
VdS
DMX3000 IP 42 --- ---
EN 12094-3
--- T G --- --- --- X --- X1 X1 --- X --- X --- --- --- --- --- 4-13
Emergency Button, blue
310-010_001 / AI01_2016en

801003
VdS
DMX3000 SF IP 42 --- --- --- T G X --- --- X --- --- --- --- --- --- --- --- --- --- --- --- 4-16
EN 12094-3
Emergency Button, blue

904465
VdS
DMX3000 LED IP 42 --- --- --- T G --- --- --- X --- --- --- --- --- X --- X --- --- --- --- 4-18
EN 12094-3
Emergency Button, blue

905352
DMX95 IP 42 --- --- --- X R A --- --- --- X --- --- --- --- --- X --- --- --- --- X --- 4-4
Internal Alarm, blue
2/2
903769 VdS
DMX3000 Ex © Viking GmbH &IPCo.
42 KG
--- | Industriestr.
1
EN 12094-3 10/12
--- T| D-23843
G --- Bad---Oldesloe
--- |X www.viking-emea.com
--- X1 X
1
--- | X Chapter
--- 4
--- - 2 --- --- --- --- --- 4-25
22 ATEX
Emergency Button, blue

915749
DMX95-I IP 43 X --- --- X R A --- --- --- X --- --- --- --- --- X --- --- --- --- --- X 4-8
Internal Alarm, blue
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95 manual call point, red Part no.: 902895


Analogue addressable manual call point for indoor areas,
in accordance with EN 54-11. An additional weatherproof
enclosure with seal set is separately available.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation. The white inside sign can be
replaced with other labels (see DMX indoor application,
accessories). Markings or labels which do not comply with
the standard will void the VdS and EN 54-11 approvals.
Operating instructions and address information are included
with the detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology / protocol Loop AP / XP95 1 Paper inlay “Out of order”
Integrated
no
short circuit isolator Not included in delivery
No. of detectors per loop for 1 Door key design “D” 173881
max. 126 units
mixed automatic and manual
Operating voltage 17 V - 28 V DC Connection / mounting
Operating current 230 μA - 300 μA Connection cable 2-wire
Alarm current 2 mA Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Alarm indication 1 red LED
Recommended cable for circuit integrity 907940
IP rating (EN 60529) IP 42 JE-H(ST)H E30 2x2x0.8 mm
with weatherproof enclosure IP 54 Conductor cross-section max. 2.5 mm2 (AWG 13)
Enclosure material Diecast aluminium Electrostatic shielding not required
Colour RAL 3001, red
Trigger mechanism material PC Note
The electronics does not have any isolators, appropriate
-20 °C to +70 °C
Operating temperature add-on modules must be taken into account.
(-4 °F to +158 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Approvals / marking
Specification according to EN 54-11
Weight approx. 500 g (1.1 lbs) G 205065 0786-CPD-20379
The contents of this publication are subject to modifications without notice. All rights reserved.

125 x 125 x 32.5 mm (WxHxD)


Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)

n u e d
o n ti
310-120_001 / AI01_2016en

1/2
Di s c
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 3
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95 manual release, yellow Part no.: 904477

Technical specifications Approvals / marking


Function Type B, latching contact
G 208061 0786-CPD-20380
Colour RAL 1021, yellow
Specification according to EN 12094-3 Otherwise like part no. 902895

Markings or labels which do not comply with the standard


will void the VdS and EN 12094-3 approvals.

Note
This MCP uses German labeling. For other languages please
use part no. 904478

DMX95 2nd release, green Part no.: 904475

Technical specifications Approvals / marking


Function Type B, non-latching contact
Colour RAL 6002, green
Specification according to similar to EN 12094-3 Otherwise like part no. 902895

Note
This MCP uses German labeling. For other languages please
use part no. 904478
The contents of this publication are subject to modifications without notice. All rights reserved.

DMX95 internal alarm, blue Part no.: 905352

Technical specifications Approvals / marking

d
Function Type B, non-latching contact

e
Colour RAL 5015, blue

u
Specification according to similar to EN 12094-3 Otherwise like part no. 902895

o n ti
Note

n
This MCP uses German labeling. For other languages please
310-120_001 / AI01_2016en

use part no. 904478

2/2
Di s c
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 4
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95 manual call point “Feuerwehr”, red Part no.: 904474


Analogue addressable manual call point for indoor areas,
similar to EN 54-11 with “FEUERWEHR” label.
An additional weatherproof enclosure with seal set is
separately available. Applicable for operation in fire alarm
panels with Loop AP protocol. Addressing via DIP switches;
the address can also be modified after installation.
The outside and the white inside sign can be replaced with
other labels (see DMX indoor application, accessories).
Operating instructions and address information are included
with the detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology / protocol Loop AP / XP95 1 Paper inlay “Out of order”
Integrated
no
short circuit isolator Not included in delivery
No. of detectors per loop for 1 Door key design “D” 173881
max. 126 units
mixed automatic and manual
Operating voltage 17 V - 28 V DC Connection / mounting
Operating current 230 μA - 300 μA Connection cable 2-wire
Alarm current 2 mA Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Alarm indication 1 red LED
Recommended cable for circuit integrity 907940
IP rating (EN 60529) IP 42 JE-H(ST)H E30 2x2x0.8 mm
with weatherproof enclosure IP 54 Conductor cross-section max. 2.5 mm2 (AWG 13)
Enclosure material Diecast aluminium Electrostatic shielding not required
Colour RAL 3001, red
Trigger mechanism material PC Note
The electronics does not have any isolators, appropriate
-20 °C to +70 °C
Operating temperature add-on modules must be taken into account.
(-4 °F to +158 °F)
This MCP uses German labeling. For other languages
Relative humidity 0 to 95% please use part no. 904478
(IEC 721-3-3) no condensation
Specification according to similar to EN 54-11
Approvals / marking
Weight approx. 500 g (1.1 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

125 x 125 x 32.5 mm (WxHxD)


Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)

n u e d
c o n ti
310-120_002/ AI01_2016en

1/1
Di s
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 5
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95 manual call point, variable Part no.: 904478

Analogue addressable manual call point for indoor areas,


Technical specifications similar to EN 54-11 or EN 12094-3.
Type B, Free selection of the detector configuration possible
Function
latching or non-latching contact (Latching or non-latching contact, silicone free, special
Technology / protokol Loop AP / XP95 labeling).
The order is placed along with an additional note on the
Integrated detector, with order number and the desired modifications.
no
short circuit isolator
Production is then performed manually. A contract review
No. of detectors per loop for will be performed in order to comply with regulations.
max. 126 units
mixed automatic and manual An additional weatherproof enclosure with seal set is
Operating voltage 17 V - 28 V DC separately available. Applicable for operation in fire alarm
panels with Loop AP protocol. Addressing via DIP switches;
Operating current 230 μA - 300 μA
the address can also be modified after installation.
Alarm current 2 mA Operating instructions and address information are included
Alarm indication 1 red LED with the detector.
IP rating (EN 60529) IP 42
with weatherproof enclosure IP 54 Included in delivery
Enclosure material Diecast aluminium Mounting hardware
RAL 3001, red 2 Cable glands M20 x 1.5
RAL 1021, yellow 1 Paper inlay “Out of order”
Colour
RAL 5015, blue
RAL 6002, green
Not included in delivery
Trigger mechanism material PC
1 Door key design “D” 173881
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
Connection / mounting
Relative humidity 0 to 95%
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation Connection cable 2-wire


Recommended cable, standard 747180
similar to EN 54-11
Specification according to J-Y(ST)Y-2x2x0.8 mm
EN 12094-3
Recommended cable for circuit integrity 907940
Weight approx. 500 g (1.1 lbs) JE-H(ST)H E30 2x2x0.8 mm

d
Conductor cross-section max. 2.5 mm2 (AWG 13)

e
125 x 125 x 32.5 mm (WxHxD)
Dimensions Electrostatic shielding not required
4.9 x 4.9 x 1.3 inch (WxHxD)

Approvals / marking

n ti
Note

n u
The electronics does not have any isolators, appropriate
add-on module must be taken into account.

o
310-120_003 / AI01_2016en

1/1
Di s c
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 6
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95-I manual call point, red Part no.: 915745


Analogue addressable manual call point for indoor areas,
in accordance with EN 54-11. An additional weatherproof
enclosure with seal set is separately available. Applicable
for operation in fire alarm panels with Loop AP protocol.
Addressing via push button; the address can also be modified
after installation. The white inside sign can be replaced with
other labels (see DMX indoor application, accessories).
Markings or labels which do not comply with the standard
will void the VdS and EN 54-11 approvals.
Operating instructions and address information are included
with the detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology / protocol Loop AP / XP95 1 Paper inlay “Out of order”
Integrated
yes
short circuit isolator Not included in delivery
No. of detectors per loop for 1 Door key design “D” 173881
max. 126 units
mixed automatic and manual Battery cable 917329
Operating voltage 17 V - 28 V DC Monobloc battery 9 V
Operating current 240 μA
Alarm current 3.7 mA
Connection / mounting
Connection cable 2-wire
Alarm indication 1 red LED
Recommended cable, standard 747180
IP rating (EN 60529) IP 43 J-Y(ST)Y-2x2x0.8 mm
with weatherproof enclosure IP 54 Recommended cable for circuit integrity 907940
Enclosure material Diecast aluminium JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Colour RAL 3001, red
Electrostatic shielding not required
Trigger mechanism material PC & PP
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
Note
The product has an integrated short circuit isolator. To set the
Relative humidity 5 to 95% address the manual call point has to be powered. The power
(IEC 721-3-3) no condensation
supply can either be realised by connecting the device to the
Specification according to EN 54-11 loop or by using a battery cable (part no.: 917329) and
Weight approx. 400 g (0.9 lbs) a common 9 V monobloc battery.
The contents of this publication are subject to modifications without notice. All rights reserved.

125 x 125 x 32.5 mm (WxHxD)


Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD) Approvals / marking

G 214084 0786-CPR-21396
310-120_004 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 7
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95-I manual release, yellow Part no.: 915747

Technical specifications Approvals / marking


Function Type B, latching contact
G 214085 0786-CPR-21397
Colour RAL 1021, yellow
Specification according to EN 12094-3 Otherwise like part no. 915745

Markings or labels which do not comply with the standard will


void the VdS and EN 12094-3 approvals.

DMX95-I 2nd release, green Part no.: 915748

Technical specifications Approvals / marking


Function Type B, non-latching contact
Colour RAL 6002, green
Specification according to similar to EN 12094-3 Otherwise like part no. 915745

DMX95-I internal alarm, blue Part no.: 915749

Technical specifications Approvals / marking


Function Type B, non-latching contact
Colour RAL 5015, blue
Specification according to similar to EN 12094-3 Otherwise like part no. 915745
The contents of this publication are subject to modifications without notice. All rights reserved.
310-120_004 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 8
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95-I manual call point “Feuerwehr”, Part no.: 915746


red Analogue addressable manual call point for indoor areas,
similar to EN 54-11 with “FEUERWEHR” label. An additional
weatherproof enclosure with seal set is separately available.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via push button; the address can also
be modified after installation. The outside and the white
inside sign can be replaced with other labels (see DMX
indoor application, accessories). Operating instructions and
address information are included with the detector.

Included in delivery
Mounting hardware
Technical specifications
2 Cable glands M20 x 1.5
Function Type B, latching contact 1 Paper inlay “Out of order”
Technology / protocol Loop AP / XP95
Integrated
yes
Not included in delivery
short circuit isolator 1 Door key design “D” 173881
No. of detectors per loop for Battery cable 917329
max. 126 units
mixed automatic and manual Monobloc battery 9 V
Operating voltage 17 V - 28 V DC
Operating current 240 μA Connection / mounting
Alarm current 3.7 mA Connection cable 2-wire
Recommended cable, standard 747180
Alarm indication 1 red LED J-Y(ST)Y-2x2x0.8 mm
IP rating (EN 60529) IP 43 Recommended cable for circuit integrity 907940
with weatherproof enclosure IP 54 JE-H(ST)H E30 2x2x0.8 mm
Enclosure material Diecast aluminium Conductor cross-section max. 1.5 mm2 (AWG 15)
Electrostatic shielding not required
Colour RAL 3001, red
Trigger mechanism material PC & PP
Note
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
The product has an integrated short circuit isolator. To set the
address the manual call point has to be powered. The power
Relative humidity 0 to 95% supply can either be realised by connecting the device to the
(IEC 721-3-3) no condensation
loop or by using a battery cable (part no.: 917329) and
Specification according to similar to EN 54-11 a common 9 V monobloc battery.
Weight approx. 400 g (0.9 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions
125 x 125 x 32.5 mm (WxHxD) Approvals / marking
4.9 x 4.9 x 1.3 inch (WxHxD)
310-120_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 9
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

DMX95-I manual call point, variable Part no.: 915750

Analogue addressable manual call point for indoor areas,


Technical specifications similar to EN 54-11 or EN 12094-3.
Type B, Free selection of the detector configuration possible
Function
latching or non-latching contact (Latching or non-latching contact, silicone free, special
Technology / protocol Loop AP / XP95 labeling).
The order is placed along with an additional note on the
Integrated detector, with order number and the desired modifications.
yes
short circuit isolator
Production is then performed manually. A contract review
No. of detectors per loop for will be performed in order to comply with regulations.
max. 126 units
mixed automatic and manual An additional weatherproof enclosure with seal set is
Operating voltage 17 V - 28 V DC separately available. Applicable for operation in fire alarm
panels with Loop AP protocol. Addressing via push button;
Operating current 240 μA
the address can also be modified after installation.
Alarm current 3.7 mA Operating instructions and address information are included
Alarm indication 1 red LED with the detector.
IP rating (EN 60529) IP 43
with weatherproof enclosure IP 54 Included in delivery
Enclosure material Diecast aluminium Mounting hardware
RAL 3001, red 2 Cable glands M20 x 1.5
RAL 1021, yellow 1 Paper inlay “Out of order”
Colour
RAL 5015, blue
RAL 6002, green
Not included in delivery
Trigger mechanism material PC
1 Door key design “D” 173881
Operating temperature
-20 °C to +60 °C Batterie cable 917329
(-4 °F to +140 °F) Monobloc batterie 9 V
Relative humidity 5 to 95%
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation


Connection / mounting
similar to EN 54-11 Connection cable 2-wire
Specification according to
and EN 12094-3
Recommended cable, standard 747180
Weight approx. 400 g (0.9 lbs) J-Y(ST)Y-2x2x0.8 mm
125 x 125 x 32.5 mm (WxHxD) Recommended cable for circuit integrity 907940
Dimensions JE-H(ST)H E30 2x2x0.8 mm
4.9 x 4.9 x 1.3 inch (WxHxD)
Conductor cross-section max. 1.5 mm2 (AWG 15)
Electrostatic shielding not required
Note
The product has an integrated short circuit isolator. To set the Approvals / marking
address the manual call point has to be powered. The power
310-120_006 / AI00_2015en

supply can either be realised by connecting the device to the


loop or by using a battery cable (part no.: 917329) and
a common 9 V monobloc battery.

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 10
Product Sheet | Detecon

Manual call points


DMX indoor application, addressable

KAX DIS 908r manual call point, red Part no.: 912579
Analogue addressable manual call point with intagreated
isolator for indoor areas, in accordance with EN 54-11.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation. Markings or labels which do not
comply with the standard will void the EN 54-11 approval.
Operating instructions and address information are included
with the detector.

Included in delivery
Technical specifications
1 Key to reset / open the MCP
Function Type A, latching contact
Technology protokol Loop AP / Discovery Not included in delivery
Integrated Mounting hardware
yes
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
max. 126 units Connection / mounting
Connection cable 2-wire
Operating voltage 17 V - 28 V DC
Recommended cable, standard 747180
Operating current 100 μA J-Y(ST)Y-2x2x0.8 mm
Alarm current 4 mA Recommended cable for circuit integrity 907940
JE-H(ST)H E30 2x2x0.8 mm
Alarm indication 1 LED, red
Conductor cross-section max. 2.5 mm2 (AWG 13)
IP rating (EN 60529) IP 24D Electrostatic shielding not required
Enclosure material PC / ABS
Colour red Approvals / marking
-30 °C to + 70 °C
Operating temperature
(-22 °F to +158 °F) 0832-CPD-2033
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54-11 und EN54-17
Weight approx. 180 g (0.40 lbs)
88 x 88 x 59 mm (WxHxD)
Dimensions
3.5 x 3.5 x 2.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
310-120_007 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 11
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 manual call point, red Part no.: 903639


Manual call point for indoor areas, conventional detector
in accordance with EN 54-11. An additional weatherproof
enclosure with seal set is separately available. Applicable
alarm for operation on conventional lines of the fire alarm
panels FMZ4100 and FMZ5000. The printed symbol (burning
house) and the white inside panel comply with EN 54-11.
The white inside sign can be replaced with other labels (see
DMX indoor application, accessories). Markings or labels
which do not comply with the standard will void the VdS and
EN 54-11 approvals. Operating instructions is included with
the detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology Conventional 1 Paper inlay “Out of order”
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC Not included in delivery
1 Door key design “D” 173881
Quiescent current 5 mA (at 9 V)
Alarm current 20 mA (at 9 V)
Connection / mounting
IP rating (EN 60529) IP 42
with weatherproof enclosure IP 54 Connection cable 2-wire
Recommended cable, standard 747180
Enclosure material Diecast aluminium J-Y(ST)Y-2x2x0.8 mm
Colour RAL 3001, red Recommended cable for circuit integrity 907940
Trigger mechanism material PC JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
-30 °C to +70 °C Electrostatic shielding not required
Operating temperature
(-22 °F to +158 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Approvals / marking
Specification according to EN 54-11
G 297003 0786-CPD-20347
Cable entry 2 x M20 x 1.5 mm (0.06 inch)
Weight approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_001 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 12
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 manual release, yellow Part no.: 888845


Otherwise like part no. 903639
Technical specifications
Function Type B, latching contact Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Colour RAL 1021, yellow
Specification according to EN 12094-3
Note
This MCP uses German labeling. For other languages please
Approvals / marking use the part no. 903246

G 207141 0786-CPD-20349

DMX3000 emergency button, blue Part no.: 888821


Otherwise like part no. 903639
Technical specifications
Markings or labels which do not comply with the standard will
Function Type B, non-latching contact
void the VdS and EN 12094-3 approvals.
Colour RAL 5015, blue
Specification according to EN 12094-3
Note
This MCP uses German labeling. For other languages please
Approvals / marking use the part no. 903246

G 207143 0786-CPD-20348
The contents of this publication are subject to modifications without notice. All rights reserved.

DMX3000 2nd release, green Part no.: 888810


Otherwise like part no. 903639
Technical specifications
Markings or labels which do not comply with the standard will
Function Type B, non-latching contact
void the VdS approval.
Colour RAL 6002, green
Specification according to similar to EN 12094-3
Note
This MCP uses German labeling. For other languages please
Approvals / marking use the part no. 903246
310-110_001 / AI01_2016en

G 207143

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 13
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 manual call point “Feuerwehr”, Part no.: 888791


red Conventional manual call point for indoor areas, similar to
EN 54-11. Labeling “FEUERWEHR” deviates from the
standard. An additional weatherproof enclosure with seal
set is separately available. Applicable for operation on
conventional lines of the fire alarm panels FMZ4100 and
FMZ5000. The outside and the white inside sign can be
replaced with other labels (see DMX indoor application,
accessories). Operating instructions is included with the
detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology Conventional 1 Paper inlay “Out of order”
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC Not included in delivery
Quiescent current 5 mA (at 9 V) 1 Door key design “D” 173881
Alarm current 20 mA (at 9 V)
IP rating (EN 60529) IP 42
Connection / mounting
with weatherproof enclosure IP 54 Connection cable 2-wire
Recommended cable, standard 747180
Enclosure material Diecast aluminium
J-Y(ST)Y-2x2x0.8 mm
Colour RAL 3001, red Recommended cable for circuit integrity 907940
Trigger mechanism material PC JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
-30 °C to +70 °C
Operating temperature
(-22 °F to +158 °F)
Electrostatic shielding not required

Relative humidity 0 to 95%


(IEC 721-3-3) no condensation Note
Specification according to similar to EN 54-11 This MCP is labeled in German. For other languages please
use the part no. 903246
Cable entry 2 x M20 x 1.5 mm (0.06 inch)
Weight approx. 500 g ( 1.1 lbs)
Approvals / marking
125 x 125 x 32.5 mm (WxHxD)
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 14
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 SF manual release, yellow Part no.: 801001


Conventional manual call point for indoor areas, in
accordance with EN 12094-3 at silicone-free design.
An additional weatherproof enclosure with seal set is
separately available. Applicable for operation on conventional
lines of the fire alarm panels FMZ4100 and FMZ5000.
Labeling in accordance with EN 12094-3. The outside sign
and the white inside sign can be replaced with other labels
(see DMX indoor application, accessories). Markings or
labels which do not comply with the standard will void the
VdS and EN 12094-3 approvals. Operating instructions is
included with the detector.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
Technology Conventional 1 Paper inlay “Out of order”
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC Not included in delivery
1 Door key design “D” 173881
Quiescent current 5 mA (at 9 V)
Alarm current 20 mA (at 9 V)
Connection / mounting
IP rating (EN 60529) IP 42
with weatherproof enclosure IP 54 Connection cable 2-wire
Recommended cable, standard 747180
Enclosure material Diecast aluminium J-Y(ST)Y-2x2x0.8 mm
Colour RAL 1021, yellow Recommended cable for circuit integrity 907940
Trigger mechanism material PC JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
-30 °C to +70 °C Electrostatic shielding not required
Operating temperature
(-22 °F to +158 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Note
This MCP uses German labeling. For other languages please
Specification according to EN 12094-3
use the part no. 903246
SF Silicone-free design
Weight approx. 500 g (1.1 lbs)
Approvals / marking
125 x 125 x 32.5 mm (WxHxD)
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)
G 207141 0786-CPD-20349
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_003 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 15
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 SF emergency button, blue Part no.: 801003

Technical specifications Otherwise like part no. 801001


Function Type B, non-latching contact Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Colour RAL 5015, blue
Specification according to EN 12094-3
Note
This MCP uses German labeling. For other languages please
Approvals / marking
use the part no. 903246

G 207143 0786-CPD-20348
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_003 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 16
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 LED manual call point, red Part no.: 904463


Conventional manual call point with red alarm indication
(LED) for indoor areas, in accordance with EN 54-11.
An additional weatherproof enclosure with seal set is
separately available for. Applicable for operation on
conventional lines alarm panels FMZ 4100 and FMZ 5000.
The printed symbol (burning house) and the white inside
panel are designed in accordance with EN 54-11.
The white inside sign can be replaced with other labels
(see DMX indoor application, accessories). Markings or
labels which do not comply with the standard will void
the VdS and EN 54-11 approvals. Operating instructions
is included with the detector.

Included in delivery
Technical specifications Mounting hardware
Function Type B, latching contact 2 Cable glands M20 x 1.5
1 Paper inlay “Out of order”
Technology Conventional
Rated voltage 9V
Not included in delivery
Operating voltage 7.6 V - 13.2 V DC
1 Door key design “D” 173881
Quiescent current 5 mA (at 9 V)
Alarm current 20 mA (at 9 V)
Connection / mounting
IP rating (EN 60529) IP 42 Connection cable 2-wire
with weatherproof enclosure IP 54 Recommended cable, standard 747180
Enclosure material Diecast aluminium J-Y(ST)Y-2x2x0.8 mm
Colour RAL 3001, red Recommended cable for circuit integrity 907940
Trigger mechanism material PC
JE-H(ST)H E30 2x2x0.8 mm
Conducter cross-section max. 2.5 mm2 (AWG 13)
-30 °C to +70 °C
Operating temperature Electrostatic shielding not required
(-22 °F to +158 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Approvals / marking
Specification according to EN 54-11
lights up red G 297003 0786-CPD-20347
LED
when button is pressed
Weight approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

DMX3000 LED Manual Call Point, red CN Part no.: 905207


310-110_004 / AI01_2016en

Version China Approvals / marking


Otherwise like part no. 904463

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 17
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 LED manual release, yellow Part no.: 904466


Otherwise like part no. 904463
Technical specifications Markings or labels which do not comply with the standard
Function Type B, latching contact will void the VdS and EN 12094-3 approvals.

Colour RAL 1021, yellow


Specification according to EN 12094-3
Note
This MCP uses German labeling. For other languages please
use the part no. 903246
Approvals / marking

G 207141 0786-CPD-20349

DMX3000 LED emergency button, blue Part no.: 904465


Otherwise like part no. 904463
Technical specifications Markings or labels which do not comply with the standard
Function Type B, non-latching contact
will void the VdS and EN 12094-3 approvals.

Colour RAL 5015, blue


Specification according to EN 12094-3
Note
This MCP uses German labeling. For other languages please
use the part no. 903246
Approvals / marking

G 207143 0786-CPD-20348

DMX3000 LED 2nd release, green


Part no.: 904464
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications Otherwise like part no. 904463


Markings or labels which do not comply with the standard
Function Type B, non-latching contact
will void the VdS approval.
Colour RAL 6002, green
Specification according to similar to EN 12094-3 Note
This MCP uses German labeling. For other languages please
Approvals / marking use the part no. 903246

G 207143
310-110_004 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 18
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX3000 manual call point, variable Part no.: 903246

Conventional manual call point for indoor areas, similar to


Technical specifications EN 54-11 or EN 12094-3.
Type B, Free selection of the detector configuration possible
Function
latching or non-latching contact (Latching or non-latching contact, silicone free, special
Technology Conventional labeling). The order are placed with an additional note on
the detector with part no. and the desired modifications.
Rated voltage 9V Production is then performed manually. A contract review
Operating voltage 7.6 V - 13.2 V DC will be performed in order to comply with regulations.
Quiescent current 5 mA (at 9 V) An additional weatherproof enclosure with seal set is
separately available.Applicable for operation on conventional
Alarm current 20 mA (at 9 V) lines of the fire alarm panels FMZ 4100 and FMZ 5000.
IP rating (EN 60529) IP 42 Operating instructions is included with the detector.
with weatherproof enclosure IP 54
Enclosure material Diecast aluminium Included in delivery
RAL 3001, red Mounting hardware
RAL 1021, yellow 2 Cable glands M20 x 1.5
Colour
RAL 5015, blue
1 Paper inlay “Out of order”
RAL 6002, green
Trigger mechanism material PC
Not included in delivery
-30 °C to +70 °C
Operating temperature
(-22 °F to +158 °F)
1 Door key design “D”  173881

Relative humidity 0 to 95%


(IEC 721-3-3) no condensation Connection / mounting
similar to EN 54-11 Connection cable  2-wire
Specification according to Recommended cable, standard 747180
and EN 12094-3
J-Y(ST)Y-2x2x0.8 mm
Weight approx. 500 g (1.1 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Recommended cable for circuit integrity 907940


125 x 125 x 32.5 mm (WxHxD) JE-H(ST)H E30 2x2x0.8 mm
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD) Conductor cross-section max. 2.5 mm2 (AWG 13)
Electrostatic shielding not required
Approvals / marking
310-110_005 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 19
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX2000 LED manual call point, red Part no.: 920843


Conventional manual call point with red alarm indication
(LED) for indoor areas, in accordance with EN 54-11.
Applicable for operation on conventional lines of alarm
panels FMZ 5000 and FMZ 5000 mod S.
The printed symbol (burning house) and the white inside
panel are designed in accordance with EN 54-11. Operating
instructions and wiring notes are included with the detector.

Included in delivery
Technical specifications 2 Blanking plugs M20 with membrane for cable feedtrough
1 Paper inlay “Out of order”
Function Type B, latching contact
1 End of line-resistor 1,8 K (built-in)
Technology Conventional
Rated voltage 9V
Not included in delivery
Operating voltage 7.6 V - 13.2 V DC Door key design “D” 173881
Quiescent current 5 mA (at 9 V) Mounting hardware
Alarm current 20 mA (at 9 V)
IP rating (EN 60529) IP 42 Connecting / mounting
Enclosure material PC / ABS Connecting cable 2-wire
Recommended cable, standard 747180
Colour RAL 3000, red
J-Y(ST)Y-2x2x0.8 mm
Trigger mechanism material PC Recommended cable for circuit integrity 907940
-10 °C to +50 °C JE-H(ST)H E30 2x2x0.8 mm
Operating temperature Conductor cross-section max. 2.5 mm2 (AWG 13)
(14 °F to 122 °F)
Electrostatic shielding not required
Relative humidity 0 to 95%
(IEC721-3-3) no condensation
Specification according to EN 54-11 Approvals / marking
lights up red when
LED
button is pressed G 296033 0786-CPD-20526
Weight approx. 230 g (0.5 lbs)
135 x 135 x 35 mm (BxHxT)
Dimensions
5.3 x 5.3 x 1.4 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_008 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 20
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

DMX2000 LED manual release, yellow Part no.: 920844

Technical specifications Included in delivery


Function Type B, latching contact English sign „MANUAL RELEASE Gas
extinguishing system“ is included with the detector.
Colour RAL 1003, yellow
Specification according to EN 12094-3
Approvals / marking
Otherwise like Part no. 920843
G 208162
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_008 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 21
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

Pull station P32-1T Part no.: 918434


Pull station for indoor use.
The pull station is a „single action“ device. By pulling the
white operating handle straight down the handle will lock into
place and the contact is triggered.

Included in delivery
Pull station P32-1T
Mounting hardware
Key

Not included in delivery


Back Box
Product features End of line-resistor (EOL)
Alarm resistor
• Single pole, single throw (H/O) with a
potential free contact for alarm
Connecting / mounting
• For indoor use
Connection cable 2-wire

Note
Technical specifications
Applicable for operation with the fire alarm panel
Function Snap action switch FMZ 5000 mod S CA (918493).
Contact Voltage max. 30 V DC/1A
Enclosure material Diecast enclosure
Colour red
Specification according to UL standard 38, 1999 Edition
LED nonexistent
Weight 440 g (1.0 lbs)
80 x 119 x 22 mm (WxHxD)
Dimensions
3.2 x 4.7 x 0.9 inch (WxHxD)
Contact 1 NO contact1

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_006 / AI01_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 22
Product Sheet | Detecon

Manual call points


DMX indoor application, conventional

Abort switch CP-4410AS Part no.: 918435


Abort switch for indoor use.
Single pole, single throw (H/O) with a potential free contact
for alarm.

Included in delivery
Abort switch CP-4410AS
Mounting hardware

Not included in delivery


Back Box
End of line-resistor (EOL)
Alarm resistor

Technical specifications Connecting / mounting


Connection cable 2-wire
Function Latching contact

Contact Voltage max. 24 V DC Note


Enclosure material Stainless steel applicable for operation with the fire alarm panel
FMZ 5000 mod S CA (918493).
Colour Stainless steel finish

LED nonexistent Connection diagram


Weight 125 g (0.3 lbs)

Dimensions 114 x 114 x 51 mm (WxHxD)

Contact 1 NO contact

Zulassungen / Kennzeichnungen
The contents of this publication are subject to modifications without notice. All rights reserved.
310-110_007 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 23
Product Sheet | Detecon

Manual call points


DMX indoor application, Ex

DMX3000 Ex manual call point, red Part no.: 903767


Conventional manual call point for indoor areas in
Ex zone 1 or 22 in accordance with EN 54-11.
An additional weatherproof enclosure with seal set is
available. Applicable for operation on conventional lines of
the fire alarm panels FMZ 4100 and FMZ 5000.
The printed symbol (house on fire) and the white inside panel
are designed in accordance with EN 54-11. The white inside
sign can be replaced with other labels (see DMX indoor appli-
cation, accessories) Markings or labels which do not comply
with the standard will void the VdS and EN 54-11 approvals.
The Ex manual call point may only be used together with
a safety barrier (see FMZ 5000 modules/cards) and a blue
fire alarm cable. Operating instructions is included with the
detector.
Technical specifications
Function Type B, latching contact Included in delivery
Mounting hardware
Technology Conventional
2 Cable glands M20 x 1.5
Rated voltage 9V 1 Paper inlay “Out of order”
Operating voltage 7.6 V - 13.2 V DC
Quiescent current 5 mA (at 9 V) Not included in delivery
Alarm current 20 mA (at 9 V) Safety barrier IS conventional 9 V 904991
1 Door key design “D”  173881
Effective inner capacity Ci = 12 nF
Effective inner inductance Li = negligible
Connection / mounting
IP rating (EN 60529) IP 42
with weatherproof enclosure IP 54 Connection cable  2-wire
Recommended cable for Ex devices 140084
Enclosure material Diecast aluminium JE-Y(ST)Y-2x2x0.8 mm, blue
Colour RAL 3001, red Conductor cross-section  max. 2.5 mm2 (AWG 13)
Trigger mechanism material PC Electrostatic shielding  not required
Operating temperature in -25 °C to +40 °C
temperature class T6 (-13 °F to +104 °F) Note
Operating temperature in -25 °C to +70 °C The call point´s metal casing is part of the local potential
temperature class T4 (-13 °F to +158 °F) equalisation.
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Approvals / marking
Specification according to EN 54-11 Ex conformity in acc. with 94/9/EC
x II 2G Ex ib IIC T6...T4 Gb
The contents of this publication are subject to modifications without notice. All rights reserved.

Ex zone Zone 1 (gas) and 22 (dust)


Weight approx. 500 g (1.1 lbs) x II 3D Ex ib IIIB T120°C Dc
Ex conformity Russia in acc. with TP TC 012/2011:
125 x 125 x 32.5 mm (WxHxD) 1Ex ia IIC T6/T4 Gb
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)

G 297003 0786-CPD-20347
310-130_001 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 24
Product Sheet | Detecon

Manual call points


DMX indoor application, Ex

DMX3000 Ex manual release, yellow Part no.: 903770

Approvals / marking
Technical specifications
Ex conformity in acc. with 94/9/EC
Function Type B, latching contact x II 2G Ex ib IIC T6...T4 Gb
Colour RAL 1021, yellow x II 3D Ex ib IIIB T120°C Dc
Specification according to EN 12094-3 Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Markings or labels which do not comply with the standard
will void the VdS and EN 12094-3 approvals.
G 207141 0786-CPD-20349
Notes
This MCP uses German labeling. For other languages please
use the part no. 904152 Otherwise like part no.: 903767

DMX3000 Ex emergency button, blue Part no.: 903769

Approvals / marking
Technical specifications
Ex conformity in acc. with 94/9/EC
Function Type B, non-latching contact x II 2G Ex ib IIC T6...T4 Gb
Colour RAL 5015, blue x II 3D Ex ib IIIB T120°C Dc
Specification according to EN 12094-3 Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Markings or labels which do not comply with the standard
will void the VdS and EN 12094-3 approvals.
G 207143 0786-CPD-20348
Notes
This MCP uses German labeling. For other languages please
use the part no. 904152 Otherwise like part no.: 903767
The contents of this publication are subject to modifications without notice. All rights reserved.

DMX3000 Ex 2nd release, green Part no.: 903768

Approvals / marking
Technical specifications
Ex conformity in acc. with 94/9/EC
Function Type B, non-latching contact x II 2G Ex ib IIC T6...T4 Gb
Colour RAL 6002, green x II 3D Ex ib IIIB T120°C Dc
Specification according to similar to EN 12094-3 Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Markings or labels which do not comply with the standard
will void the VdS approval.
310-130_001 / AI01_2016en

G 207143
Notes
This MCP uses German labeling. For other languages please
use the part no. 904152 Otherwise like part no.: 903767

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 25
Product Sheet | Detecon

Manual call points


DMX indoor application, Ex

DMX3000 Ex manual call point, variable Part no.: 904152

Conventional manual call point for indoor areas in


Technical specifications Ex zone 1 or 22, similar to EN 54-11 or EN 12094-3.
Type B, Free selection of detector configuration possible
Function
latching or non-latching contact (Latching or non-latching contact, silicone free, special
Technology Conventional labeling). The order is placed along with an additional
note on the detector, with order number and the desired
Rated voltage 9V
modifications. Production is then performed manually.
Operating voltage 7.6 V - 13.2 V DC A contract review will be performed in order to
Quiescent current 5 mA (at 9 V) comply with regulations. An additional weatherproof
Alarm current 20 mA (at 9 V) enclosure with seal set is available. Applicable for operation
Effective inner capacity Ci = 12 nF on conventional lines fire alarm panels FMZ 4100 and FMZ
5000. The Ex manual call point may only be used together
Effective inner inductance Li = negligible
with a safety barrier (see FMZ 5000 modules/cards) and a
IP rating (EN 60529) IP 42 blue fire alarm cable. Operating instructions is included with
with weatherproof enclosure IP 54 the detector.
Enclosure material Diecast aluminium
RAL 3001, red
RAL 1021, yellow
Included in delivery
Colour Mounting hardware
RAL 5015, blue
RAL 6002, green 2 Cable glands M20 x 1.5
Trigger mechanism material PC 1 Paper inlay “Out of order”
Operating temperature in -25 °C to +40 °C
temperature class T6 (-13 °F to +104 °F) Not included in delivery
Operating temperature in -25 °C to +70 °C Safety barrier IS conventional 9 V 904991
temperature class T4 (-13 °F to +158 °F) 1 Door key design “D”  173881
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Connection / mounting
The contents of this publication are subject to modifications without notice. All rights reserved.

similar to EN 54-11
Specification according to Connection cable  2-wire
and EN 12094-3
Recommended cable for Ex devices 140084
Ex zone Zone 1 (gas) and 22 (dust) JE-Y(ST)Y-2x2x0.8 mm, blue
Weight approx. 500 g (1.1 lbs) Conductor cross-section  max. 2.5 mm2 (AWG 13)
125 x 125 x 32.5 mm (WxHxD) Electrostatic shielding not required
Dimensions
4.9 x 4.9 x 1.3 inch (WxHxD)

Note
Approvals / marking The call point´s metal casing is part of the local potential
Ex conformity in acc. with 94/9/EC equalisation.
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
310-130_002 / AI01_2016en

Ex conformity Russia in acc. with TP TC 012/2011:


1Ex ia IIC T6/T4 Gb

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 26
Product Sheet | Detecon

Manual call points


DMX indoor application, accessories

Weatherproof enclosure, red Part no.: 903792


With the weatherproof enclosure, the protection
Technical specifications rating rises from IP42 to IP54 for the manual call points
DMX3000, DMX3000 Ex, DMX95-I and DMX95.
Colour RAL 3001, red
Weight 0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5

Weatherproof enclosure, yellow Part no.: 903779


With the weatherproof enclosure, the protection
Technical specifications rating rises from IP42 to IP54 for the manual call points
DMX3000, DMX3000 Ex, DMX95-I and DMX95.
Colour RAL 1021, yellow
Weight 0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5

Weatherproof enclosure, blue Part no.: 903780


With the weatherproof enclosure, the protection
Technical specifications rating rises from IP42 to IP54 for the manual call points
DMX3000, DMX3000 Ex, DMX95-I and DMX95.
Colour RAL 5015, blue
Weight 0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5
The contents of this publication are subject to modifications without notice. All rights reserved.

Weatherproof enclosure, green Part no.: 903791


With the weatherproof enclosure, the protection
Technical specifications rating rises from IP42 to IP54 for the manual call points
DMX3000, DMX3000 Ex, DMX95-I and DMX95.
Colour RAL 6002, green
Weight 0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5
310-140_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 27
Product Sheet | Detecon

Manual call points


DMX indoor application, accessories

Detector element DMX symbol Part no.: 904449

Detector element DMX symbol LED Part no.: 904450

DMX3000 card Part no.: 907764

DMX3000 card, LED Part no.: 907765

DMX3000 card, 2GRU Part no.: 907766

DMX3000 card, LED ext. Part no.: 907728

DMX95 card Part no.: 907942

Special labeling for outside and Part no.: 903371


inside sign
The contents of this publication are subject to modifications without notice. All rights reserved.

French labeling Part no.: 904292


310-140_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 28
Product Sheet | Detecon

Manual call points


DMX outdoor application

Overview outdoor application

Application Accessories Replacement

Special labeling for white


Non-Latching contact (T)

Board DMX3100, SUX50,


Board DMX3100 SUX95,

Board DMX3100 SUX95,

2GRU, switch (907887)


Application

inside panel (907192)

ZDP, switch (907886)


Short circuit isolator

Latching contact (R)


(further approval on

Catalogue chapter
Individual labeling
Approvals/ Norms

Conventional (G)

Board DMX3100,

Board DMX3100,

Board DMX3100,

Board DMX3100,
Addressable (A)

button (907884)
switch (907883)
button (907912)
catalogue page)

switch (907890)

switch (907889)
Accessories

Silicone-free
Alarm-LED

(outside)
IP rating

Ex Zone
Replacement

906939
VdS
DMX3100 IP 66 --- ---
EN 54-11
--- R G --- X1 --- --- --- X --- --- --- --- 4-38
Manual Call Point, red

918153
IP 66 --- --- --- --- R G --- X1 --- --- --- X --- --- --- --- 4-42
DMX3100, red

908622 VdS
DMX3195-I IP 66 X --- EN 54-11 --- R A --- X1 --- --- --- --- --- --- --- --- 4-31
Manual Call Point, red EN 54-17

910815
DMX3195-I, red IP 66 X --- __ --- R A --- X1 BA --- --- --- --- --- --- --- 4-33

912580
KAX DIS 951r WP IP 67 X --- X R A --- --- --- --- --- --- --- --- --- --- 4-37
EN 54-11
Manual Call Point, red

908711 VdS
1
dc31 Ex IP 66 --- EN 54-11 --- R G --- X1 --- --- --- --- --- --- --- --- 4-47
21 ATEX
Manual Call Point, red

901321
0 EN 54-11
KAX95 Ex IP 67 --- X R A --- --- --- --- --- --- --- --- --- --- 4-45
20 ATEX
Manual Call Point, red

906940
VdS
DMX3100 IP 66 --- ---
EN 12094-3
--- R G --- X1 --- --- --- X --- --- --- --- 4-39
Manual Release, yellow

918154
IP 66 --- --- --- --- R G --- X1 --- --- --- X --- --- --- --- 4-43
DMX3100, yellow

907024
VdS
DMX3100 2GRU IP 66 --- ---
EN 12094-3
--- R G --- X1 --- --- --- --- --- X --- --- 4-40
Manual Release, yellow

908623 VdS
DMX3195-I IP 66 X --- EN 12094-3 --- R A --- X1 LU --- --- --- --- --- --- --- 4-32
Manual Release, yellow EN 54-17
The contents of this publication are subject to modifications without notice. All rights reserved.

910553
DMX3195-I, yellow IP 66 X --- --- --- R A --- X1 BA --- --- --- --- --- --- --- 4-34

908712 VdS
1
dc31 Ex IP 66 --- EN 12094-3 --- R G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
Manual Release, yellow

912581
0
KAX95 Ex IP 67 --- ATEX X R A --- --- --- --- --- --- --- --- --- --- 4-46
20
Manual Release, yellow

907021
VdS
DMX3100 IP 66 --- ---
EN 12094-3
--- T G --- X1 --- --- --- --- X --- --- --- 4-39
Emergency Button, blue

918155
IP 66 --- --- --- --- T G --- X1 --- --- --- --- X --- --- --- 4-44
310-010_002 / AI01_2016en

DMX3100, blue

910554
DMX3195-I, blue IP 66 X --- --- --- T A --- X1 BA --- --- --- --- --- --- --- 4-35

908713 VdS
1
dc31 Ex IP 66 --- EN 12094-3 --- T G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
Emergency Button, blue

1/2 907022
DMX3100 © Viking GmbH & Co.
IP KG
66 | Industriestr.
--- --- 10/12
VdS
| D-23843
EN 12094-3
--- Bad
T Oldesloe
G ---| www.viking-emea.com
X1 --- --- | ---
Chapter
--- 4 - 29
X --- --- --- 4-39
2nd Release, green

918156
IP 66 --- --- --- --- T G --- X1 --- --- --- --- X --- --- --- 4-44
DMX3100, green
VdS
DMX3100 2GRU IP 66 --- ---
EN 12094-3
--- R G --- X1 --- --- --- --- --- X --- --- 4-40
Manual Release, yellow

908623 VdS
DMX3195-I Product Sheet |IPDetecon
66 X --- EN 12094-3 --- R A --- X1 LU --- --- --- --- --- --- --- 4-32
Manual Release, yellow EN 54-17

910553
DMX3195-I, yellow IP 66 X --- --- --- R A --- X1 BA --- --- --- --- --- --- --- 4-34

Manual call points


908712 VdS
1
DMX
dc31 Ex outdoor application
Manual Release, yellow
IP 66 ---
21
EN 12094-3
ATEX
--- R G --- X1 --- --- --- --- --- --- --- --- 4-48

912581
Overview
KAX95 Ex outdoor application
IP 67 ---
0
20
ATEX X R A --- --- --- --- --- --- --- --- --- --- 4-46
Manual Release, yellow

907021
VdS
DMX3100 IP 66 --- ---
EN 12094-3
--- T G --- X1 --- --- --- --- X --- --- --- 4-39
Emergency Button, blue Application Accessories Replacement

Special labeling for white


918155

Non-Latching contact (T)

Board DMX3100, SUX50,


Board DMX3100 SUX95,

Board DMX3100 SUX95,


X1

2GRU, switch (907887)


Application IP 66 --- --- --- --- T G --- --- --- --- --- X --- --- --- 4-44

inside panel (907192)

ZDP, switch (907886)


Short circuit isolator

Latching contact (R)


DMX3100, blue

(further approval on

Catalogue chapter
Individual labeling
Approvals/ Norms

Conventional (G)

Board DMX3100,

Board DMX3100,

Board DMX3100,

Board DMX3100,
Addressable (A)

button (907884)
switch (907883)
catalogue page)

button (907912)
switch (907890)

switch (907889)
Accessories

Silicone-free
Alarm-LED

(outside)
IP rating

910554 Ex Zone
DMX3195-I, blue
Replacement IP 66 X --- --- --- T A --- X1 BA --- --- --- --- --- --- --- 4-35

908713 VdS
1
dc31 Ex IP 66 --- EN 12094-3 --- T G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
Emergency Button, blue

907022
906939
VdS
DMX3100 IP 66 --- --- EN
EN12094-3
54-11
--- T
R G --- X1 --- --- --- ---
X X
--- --- --- --- 4-39
4-38
2nd Release,
Manual greenred
Call Point,

918153
918156 1
IP
IP 66
66 ---
--- ---
--- ---
--- ---
--- R
T G
G ---
--- X
X1 ---
--- ---
--- ---
--- X
--- ---
X ---
--- ---
--- ---
--- 4-42
4-44
DMX3100,
DMX3100, red
green

908622 VdS
910824
DMX3195-I IP 66 X --- EN 54-11 --- R A --- X11 --- --- --- --- --- --- --- --- 4-31
DMX3195-I,
Manual green red
Call Point, IP 66 X --- ---
EN 54-17 --- T A --- X BA --- --- --- --- --- --- --- 4-35

910815
908714
DMX3195-I, red IP 66 X ---
1
VdS
__ --- R A --- X1 BA --- --- --- --- --- --- --- 4-33
dc31 Ex IP 66 --- EN 12094-3 --- T G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
2nd Release, green
912580
KAX DIS 951r WP
909032 IP 67 X --- X R A --- --- --- --- --- --- --- --- --- --- 4-37
EN 54-11
Manual
DMX3100Call Point, red IP 66 --- --- X2 --- X2 G AA X1 X1 --- --- X2 X2 --- --- --- 4-41
variable
908711 VdS
1
dc31 Ex IP 66 --- EN 54-11 --- R G --- X1 --- --- --- --- --- --- --- --- 4-47
910725 21 ATEX
Manual Call Point, red 2 2 1 1
DMX3195-I IP 66 X --- X2 --- X A AA X X --- --- --- --- --- --- --- 4-36
variable
901321
0 EN 54-11
KAX95 Ex IP 67 --- X R A --- --- --- --- --- --- --- --- --- --- 4-45
20 ATEX
Manual Call Point, red
2 2 2 2 2 2 2
Older DMX versions --- --- --- --- --- --- --- --- --- --- X X X X X X X ---
906940
VdS 1
DMX3100 IP 66 --- --- --- R G --- X --- --- --- X --- --- --- --- 4-39
EN 12094-3
Manual Release, yellow

X1 = Manual Call Point is perhaps not approval compliant


918154
IP 66 --- --- --- --- R G --- X1 --- --- --- X --- --- --- --- 4-43
DMX3100, yellow
2
X = Depending on the variable type of detector
907024
VdS
DMX3100 2GRU IP 66 --- ---
EN 12094-3
--- R G --- X1 --- --- --- --- --- X --- --- 4-40
Manual Release, yellow
AA = On request
908623 VdS
DMX3195-I IP 66 X --- EN 12094-3 --- R A --- X1 LU --- --- --- --- --- --- --- 4-32
LU = Included in delivery
Manual Release, yellow (see labeling table at the product page)
EN 54-17
The contents of this publication are subject to modifications without notice. All rights reserved.

910553
DMX3195-I, yellow IP 66
BA = Information about the labeling required
X --- --- --- R A --- X1 BA --- --- --- --- --- --- --- 4-34

908712 VdS
1
dc31 Ex IP 66 --- EN 12094-3 --- R G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
Manual Release, yellow

912581
0
KAX95 Ex IP 67 --- ATEX X R A --- --- --- --- --- --- --- --- --- --- 4-46
20
Manual Release, yellow

907021
VdS
DMX3100 IP 66 --- ---
EN 12094-3
--- T G --- X1 --- --- --- --- X --- --- --- 4-39
Emergency Button, blue

918155
IP 66 --- --- --- --- T G --- X1 --- --- --- --- X --- --- --- 4-44
310-010_002 / AI01_2016en

DMX3100, blue

910554
DMX3195-I, blue IP 66 X --- --- --- T A --- X1 BA --- --- --- --- --- --- --- 4-35

908713 VdS
1
dc31 Ex IP 66 --- EN 12094-3 --- T G --- X1 --- --- --- --- --- --- --- --- 4-48
21 ATEX
Emergency Button, blue

2/2 907022
VdS
DMX3100 © Viking GmbH & Co.
IP KG
66 | Industriestr.
--- ---
EN10/12 | D-23843
12094-3
--- TBad Oldesloe
G X1
---| www.viking-emea.com
--- --- | ---Chapter
--- 4 - X
30 --- --- --- 4-39
2nd Release, green

918156
IP 66 --- --- --- --- T G --- X1 --- --- --- --- X --- --- --- 4-44
DMX3100, green
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I manual call point, red Part no.: 908622


Analogue addressable manual call point for outdoor areas,
in accordance with EN 54-11. Applicable for operation in
fire alarm panels with Loop AP protocol. Addressing via DIP
switches; the address can also be modified after installation.
The detector has a built-in isolator.
If the labeling does not comply with VdS or EN 54-11
standards, the part no. 910815 or 910725 must be used.
The white internal plate can be replaced by other labeling
(see DMX External application accessories).
If the labeling does not comply with applicable standards, the
VdS and EN 54-11 approvals will void.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology / protocol Loop AP / XP95 2 Cable glands M20 x 1.5
1 Blanking plug
Integrated
yes
short circuit isolator
Operating voltage 17 V - 28 V DC Connection / mounting
Operating current 200 μA
Connection cable 2-wire
Recommended cable, standard 747180
Starting current (max.) 1 mA J-Y(ST)Y-2x2x0.8 mm
IP rating (EN 60529) IP 66 Recommended cable for circuit integrity 907940
Enclosure material PC JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour RAL 3001, red Electrostatic shielding not required
Trigger mechanism material POM

Operating temperature
-20 °C to +60 °C Note
(-4 °F to +140 °F)
Strong magnetic fields should be avoided in the vicinity
Relative humidity 0 to 95% of the detectors.
(IEC 721-3-3) no condensation
Specification according to EN 54-11
Approvals / marking
Weight 526 g (1.2 lbs)
135 x 161 x 61 mm (WxHxD G 211004 0786-CPD-21146
Dimensions
5.3 x 6.3 x 2.4 inch (WxHxD))
The contents of this publication are subject to modifications without notice. All rights reserved.
310-320_001 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 31
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I manual release, yellow Part no.: 908623


The manual call point in the yellow enclosure according to EN
Technical specifications 12094-3 can be used for the electrical triggering of gas extin-
guishing systems. If the labeling does not comply with VdS or
Function Type B, latching contact
EN 12094-3, the part no. 910553 or 910725 must be used.
Colour similar RAL 1021, yellow If the labeling does not comply with applicable standards, the
Specification according to EN 12094-3 VdS and EN 12094-3 approvals will void.

Excerpt from label texts Included in delivery


Mounting hardware
2 Cable glands M20 x 1.5
1 Door key
1 Blanking plug
1 Labeling kit (multilingual) with 14 labels see excerpt
from label texts

Note
The labeling kit (multilingual) complies with EN 12094-3
for national and international applications.

Approvals / marking

G 211011 0786-CPD-21147
The contents of this publication are subject to modifications without notice. All rights reserved.
310-320_001 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 32
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I, red Part no.: 910815


Analogue addressable manual call point for outdoor areas
similar to EN 54-11. Applicable for operation in fire alarm
panels with Loop AP protocol. Addressing via DIP switches.
The address can also be modified after installation.
The detector has a built-in isolator. For use of the manual
call point in other applications, such as „Fire alarm“, the
inscription label is affixed on the enclosure by the factory.
The white internal plate can be replaced by other labeling
(see DMX External application accessories). In case of
order the arbitrary/variable label text it is to be indicated
under „Information for production“.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology / protocol Loop AP / XP95 2 Cable glands M20 x 1.5
1 Blanking plug
Integrated
yes
short circuit isolator
Operating voltage 17 V - 28 V DC Connection / mounting
Operating current 200 μA
Connection cable  2-wire
Recommended cable, standard 747180
Starting current (max.) 1 mA J-Y(ST)Y-2x2x0.8 mm
IP rating (EN 60529) IP 66 Recommended cable for circuit integrity 907940
Enclosure material PC JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour similar to RAL 3001, red Electrostatic shielding not required
Trigger mechanism material POM plastic

Operating temperature
-20 °C to +60 °C Note
(-4 °F to +140 °F)
Strong magnetic fields are to be avoided in the vicinity
Relative humidity 0 to 95% of the detectors.
(IEC 721-3-3) no condensation
Weight 526 g (1.2 lbs)
Excerpt from label texts
135 x 161 x 61 mm (WxHxD)
Dimensions
5.3 x 6.3 x 2.4 inch (WxHxD) Drucktext Sprache Deutsche
Übersetzung
FEUERALARM deutsch Feueralarm
FEUERWEHR deutsch Feuerwehr

FIRE ALARM englisch Feueralarm


The contents of this publication are subject to modifications without notice. All rights reserved.

ALARMA DE INCENDIO spanisch Feueralarm

ALARME INCENDIE französisch (Brand-) Feueralarm


ALARME FEU französisch Feueralarm

ALLARME ANTINCENDIO italienisch Feueralarm

HANDMELDER holländisch Handmelder

POŻAR polnisch Feueralarm

POŽIARNY POPLACH slowakisch Feueralarm

‫إﻧﺬار اﻟﺤﺮﻳﻖ‬ arabisch Feueralarm

FIRE ALARM engl./arab. Feueralarm


‫إﻧﺬار اﻟﺤﺮﻳﻖ‬
POŽIARNY POPLACH slowak./engl. Feueralarm
310-320_002 / AI00_2015en

FIRE ALARM

1/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 33
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I, yellow Part no.: 910553

Technical specifications In case of order the arbitrary/variable label text it is


Function Type B, latching contact to be indicated under „Information for production“
(see excerpt from label texts).
Colour similar to RAL 1021, yellow
Otherwise like part no.: 910815
Excerpt from label texts

Drucktext Sprache Deutsche /engl. Drucktext Sprache Deutsche /engl.


Übersetzung Übersetzung
HANDAUSLÖSUNG deutsch Handauslösung
WATER RELEASE engl./arab. Wasserauslösung
HANDAUSLÖSUNG - Löschanlage deutsch Handauslösung - Löschanlage
LÖSCHANLAGE deutsch Löschanlage ‫إﻃﻼق اﻟﻤﻴﺎﻩ‬
GAS RELEASE engl./arab. Gasauslösung
MANUAL RELEASE englisch Handauslösung ‫إﻃﻼق اﻟﻐﺎز‬
CO2 RELEASE englisch CO2-Auslösung FOAM RELEASE engl./arab. Schaumauslösung
CO2 MANUAL RELEASE englisch CO2 Handauslösung
WATER RELEASE englisch Wasserauslösung ‫إﻃﻼق اﻟﺮﻏﻮﻩ‬
GAS RELEASE englisch Gasauslösung FOAM MONITOR RELEASE engl./arab. Foam Monitor Release
DELUGE MANUAL RELEASE englisch Sprühflut Handauslösung ‫ﻣﺮاﻗﺐ إﻃﻼق اﻟﺮﻏﻮﻩ‬
FOAM INJECTION engl./arab. Foam Injection
DISPARO MANUAL spanisch Handauslösung
‫ﺣﻘﻦ اﻟﺮﻏﻮﻩ‬
COMMANDE MANUELLE französisch Handauslösung FOAM DYKE engl./arab. Foam Dyke
DECLENCHEMENT MANUEL französisch Handauslösung ‫ﺣﺎﺟﺰ اﻟﺮﻏﻮﻩ‬
DECLENCHEMENT CO2 französisch CO2 Auslösung
MANUAL RELEASE engl./russ. Handauslösung
RILASCIO MANUALE italienisch Handauslösung PУЧНOЙ ПУCК
BLUSSING holländisch Löschung
CO2 RUČNÉ SPUSTENIE slowak./engl. CO2-Handauslösung
HAND ACTIVERING holländisch Manuelle Löschung
MANUELE BEDIENING holländisch Manuelle Bedienung
CO2 MANUAL RELEASE
BEDIENING BLUSINSTALLATIE holländisch Bedienung Löschen
SPROEIVLOED holländisch Löschmittel Zufuhr RUČNÉ SPUSTENIE DELUZNE slowak./engl. Sprühflut Handauslösung
DELUGE MANUAL RELEASE
DECLANŞARE MANUALĂ rumänisch Handauslösung

RUČNÉ SPUSTENIE slowakisch Handauslösung


CO2 RUČNÉ SPUSTENIE slowakisch CO2 Handauslösung
RUČNÉ SPUSTENIE DELUZNE slowakisch Sprühflut Handauslösung Approvals / marking
arabisch Handauslösung
‫إﻃﻼق ﻳﺪوي‬
The contents of this publication are subject to modifications without notice. All rights reserved.

arabisch Wasserauslösung
‫إﻃﻼق اﻟﻤﻴﺎﻩ‬
arabisch Gasauslösung
‫إﻃﻼق اﻟﻐﺎز‬
arabisch Schaumauslösung
‫إﻃﻼق اﻟﺮﻏﻮﻩ‬
arabisch Foam Monitor Release
‫ﻣﺮاﻗﺐ إﻃﻼق اﻟﺮﻏﻮﻩ‬
arabisch Foam Injection
‫ﺣﻘﻦ اﻟﺮﻏﻮﻩ‬
arabisch Foam Dyke
‫ﺣﺎﺟﺰ اﻟﺮﻏﻮﻩ‬
MANUAL RELEASE engl./arab. Handauslösung
‫إﻃﻼق ﻳﺪوي‬

CO2 RUČNÉ SPUSTENIE slowak./engl. CO2-Handauslösung


CO2 MANUAL RELEASE
310-320_002 / AI00_2015en

RUČNÉ SPUSTENIE DELUZNE slowak./engl. Sprühflut Handauslösung


DELUGE MANUAL RELEASE

2/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 34
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I, green Part no.: 910824


In case of order the arbitrary/variable label text it is
Technical specifications to be indicated under „Information for production“
Function Type B, non-latching contact (see excerpt from label texts).
Colour similar to RAL 6002, green Otherwise like part no.: 910815

Excerpt fromw label texts


Approvals / marking Drucktext Sprache Deutsche
Übersetzung
NACHLÖSCHEN deutsch Nachlöschen
NACHFLUTEN - Gaslöschanlage deutsch NACHFLUTEN - Gaslöschanlage
2-te AUSLÖSUNG deutsch 2-te Auslösung
2-te LÖSCHAUSLÖSUNG deutsch 2-te Löschauslösung

2nd RELEASE englisch 2-te Auslösung


2nd EXT. RELEASE englisch 2-te Löschauslösung

STINGERE SUPLIMENTARĂ rumänisch Nachlöschen

CO2 DOHASENIE slowakisch CO2 Nachlöschen


DOHASENIE slowakisch Nachlöschen

DOHASENIE slowak./engl. Nachlöschen


SECOND DISCHARGE

DMX3195-I, blue Part no.: 910554

In case of order the arbitrary/variable label text it is


Technical specifications to be indicated under „Information for production“
Function Type B, non-latching contact (see excerpt from label texts).
Otherwise like part no.: 910815
Colour similar to RAL 5015, blue

Excerpt from label texts


Drucktext Sprache Deutsche / engl.
Übersetzung Drucktext Sprache Deutsche / engl.
AVARINIS STABDYMAS litauisch EMERGENCY STOP Übersetzung
The contents of this publication are subject to modifications without notice. All rights reserved.

Gesinimo dujomis sistema Gas extinguishing system LÖSCHVERZUG deutsch Löschverzug


HAUSALARM deutsch Hausalarm
STOP - AVĀRIJAS IZSLĒGŠANA lettisch STOPP-TASTER - Gaslöschanlage STOPP-TASTER Gaslöschanlage deutsch STOPP-TASTER - Gaslöschanlage
Dzēšanas sistēma ar gāzi HANDBRANDMELDER deutsch Handbrandmelder

EMERGENCY STOP englisch STOPP-TASTER - Gaslöschanlage


HÄTÄPYSÄYTYS – finnisch STOPP-TASTER - Gaslöschanlage Gas extinguishing system
Kaasusammutuslaitteistot EXTINGUISHING DELAY englisch Löschverzug

NÖDSTOPP – schwedisch STOPP-TASTER - Gaslöschanlage PARO DE EMERGENCIA – spanisch STOPP-TASTER - Gaslöschanlage


Gassläcksystem Sistema de extinction por gas
RETARDO DE DESCARGA spanisch Löschverzug
ΔIAKOΠTHΣ EKTAKTHΣ ANAΓKHΣ – griechisch STOPP-TASTER - Gaslöschanlage
Συστημα κατασβεσης με αεριο ARRET D'URGENCE – französisch STOPP-TASTER - Gaslöschanlage
Système d'extinction à gaz
RETARDEMENT D'EXTINCTION GAZ französisch Löschverzug
CO2 CTOП russisch CO2-Stopp
ARRESTO DI EMERGENZA – italienisch STOPP-TASTER - Gaslöschanlage
arabisch Löschverzug
‫ﺗﺄﺧﻴﺮ اﻹﻃﻔﺎء‬ Impianto di estinzione a gas
ARRESTO CO2 italienisch CO2-Stopp
310-320_002 / AI00_2015en

EXTINGUISHING DELAY engl./arab. Löschverzug NOODSTOP – holländisch STOPP-TASTER - Gaslöschanlage


Blusgas installatie
‫ﺗﺄﺧﻴﺮ اﻹﻃﻔﺎء‬
UITSTEL BLUSSING holländisch Löschung aus
АВАРИЙНО СПИРАНЕ bulgarisch STOPP-TASTER - Gaslöschanlage
Инсталация эа гасене с газообраэно
вещество
Approvals / marking

3/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 35
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

DMX3195-I, variable Part no.: 910725

Analogue addressable manual call point for outdoor areas


Technical specifications
similar to EN 54-11 or EN 12094-3. Free selection of
Function
Type B, the detector configuration possible (Latching or
latching or non-latching contact non-latching contact, silicone free, special labeling).
Technology / protocol Loop AP / XP95 Applicable for operation in fire panels with Loop AP
protocol. Addressing via DIP switches. The address can
Integrated
short circuit isolator
yes also be modified after installation. The order is placed along
with an additional note on the detector, with order number
Rated voltage 9V and the desired modifications. Production is then performed
Operating voltage 17 V - 28 V DC manually. A contract review will be performed in order to
Operating current 200 mA comply with regulations. The description and connection
instructions are attached to the detector.
Initial current max. 1 mA
IP rating (EN 60529) IP 66
Included in delivery
Enclosure material PC Mounting hardware
RAL 3001, red 1 Door key
RAL 1021, yellow 2 Cable glands M20 x 1.5
Colour
RAL 5015, blue 1 Blanking plug
RAL 6002, green
Trigger mechanism material POM plastic
Connection / mounting
-20 °C to +60 °C Connection cable 2-wire
Operating temperature
(-4 °F to +140 °F)
Recommended cable, standard 747180
Relative humidity 0 to 95% J-Y(ST)Y-2x2x0.8 mm
(IEC 721-3-3) no condensation Recommended cable for circuit integrity 907940
similar to EN 54-11 JE-H(ST)H E30 2x2x0.8 mm
Specification according to
and EN 12094-3 Conductor cross-section max. 2.5 mm2 (AWG 13)
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight approx. 525 g (1.16 lbs) Electrostatic shielding not required


135 x 161 x 61 mm (WxHxD)
Dimensions
5.3 x 6.3 x 2.4 inch (WxHxD) Note
Strong magnetic fields are to be avoided in the vicinity
of the detectors.

Approvals / marking
310-320_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 36
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable

KAX DIS 951r WP manual call point, red Part no.: 912580
Analogue addressable manual call point outdoor areas with
integreated isolator, in accordance with EN 54-11.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation. Markings or labels which do not
comply with the standard will void the EN 54-11 approval.
Operating instructions and address information are included
with the detector.

Included in delivery
Technical specifications
1 Key to reset / open the MCP
Function Type A, latching contact
Technology / protocol Loop AP / Discovery Not included in delivery
Integrated Mounting hardware
yes
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
max. 126 pieces Connection / mounting
Connection cable  2-wire
Operating voltage 17 V - 28 V DC
Recommended cable, standard 747180
Operating current 100 μA J-Y(ST)Y-2x2x0.8 mm
Alarm current 4 mA Recommended cable for circuit integrity 907940
JE-H(ST)H E30 2x2x0.8 mm
Alarm indication 1 LED, red
Conductor cross-section max. 2.5 mm2 (AWG 13)
IP rating (EN 60529) IP 67 Electrostatic shielding not required
Enclosure material PC / ABS
Colour red Approvals / marking
-40 °C to + 70 °C
Operating temperature
(-40 °F to +158 °F)
0359-CPD-0186
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54-11 and EN 54-17
Weight approx. 330 g (0.73 lbs)
112 x 112 x 71 mm (WxHxD)
Dimensions
4.4 x 4.4 x 2.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
310-320_004 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 37
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 manual call point, red Part no.: 906939


Conventional manual call point for outdoor areas in
accordance with EN 54-11. Applicable for operation on
conventional lines of the fire alarm panels FMZ 4100 and
FMZ 5000. The white inside sign can be replaced with other
labels (see DMX outdoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology Conventional 2 Cable glands M20 x 1.5
1 Blanking plug
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC
Connection / mounting
Quiescent current 5 mA (at 9 V)
Connection cable  2-wire
Alarm current 20 mA (at 9 V) Recommended cable, standard 747180
IP rating (EN 60529) IP 66 J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity 907940
Enclosure material PC
JE-H(ST)H E30 2x2x0.8 mm
Colour RAL 3001, red Conductor cross-section max. 2.5 mm2 (AWG 13)
Trigger mechanism material POM plastic Electrostatic shielding not required
- 35 °C to +60 °C
Operating temperature
(-31 °F to +140 °F) Note
Relative humidity 0 to 95% Strong magnetic fields should be avoided in the vicinity
(IEC 721-3-3) no condensation of the detectors.
Specification according to EN 54-11
Weight 475 g (1.1 lbs) Approvals / marking
135 x 161 x 61 mm (WxHxD)
Dimensions
5.3 x 6.3 x 2.4 inch (WxHxD) G 209029 0786-CPD-20688
The contents of this publication are subject to modifications without notice. All rights reserved.
310-310_001 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 38
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 manual release, yellow Part no.: 906940

Technical specifications Approvals / marking


Function Type B, latching contact
G 209030 0786-CPD-20689
Colour RAL 1021, yellow
Specification according to EN 12094-3

Note Otherwise like part no. 906939


This MCP uses German labeling. Markings or labels which do not comply with the standard
For other languages please use the part no. 909032 will void the VdS and EN 12094-3 approvals.

DMX3100 emergency button, blue Part no.: 907021

Technical specifications Approvals / marking


Function Type B, non-latching contact
G 209031 0786-CPD-20690
Colour RAL 5015, blue
Specification according to EN 12094-3

Note Otherwise like part no. 906939


This MCP uses German labeling. Markings or labels which do not comply with the standard
For other languages please use the part no. 909032 will void the VdS and EN 12094-3 approvals.

DMX3100 2nd release, green Part no.: 907022


The contents of this publication are subject to modifications without notice. All rights reserved.

The outside sign is as specified by VdS 2496 Issue 12.96.


Technical specifications
Function Type B, non-latching contact Approvals / marking
Colour RAL 6002, green
G 209031
Specification according to similar to EN 12094-3

Note Otherwise like part no. 906939


This MCP uses German labeling. Markings or labels which do not comply with the standard will
For other languages please use the part no. 909032 void the VdS approval.
310-310_001 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 39
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 2GRU manual release, yellow Part no.: 907024


Conventional manual call point for outdoor areas in
accordance with EN 12094-3. Applicable for operation on
conventional lines of the fire alarm panels FMZ 4100 and
FMZ 5000. The outside sign and the white inside sign can
be replaced with other labels (see DMX outdoor application,
accessories). Markings or labels which do not comply with
the standard will void the VdS and EN 12094-3 approvals.
The DMX3100 2GRU is designed for 2-line/zone coincidence.
Two alarm lines are activated if the trigger button is pressed.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology Conventional 2 Cable glands M20 x 1.5
1 Blanking plug
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC
Connection / mounting
Quiescent current 5 mA (at 9 V)
Connection cable  2-wire
Alarm current 20 mA (at 9 V) Recommended cable, standard 747180
IP rating (EN 60529) IP 66 J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity 907940
Enclosure material PC
JE-H(ST)H E30 2x2x0.8 mm
Colour RAL 1021, yellow Conductor cross-section max. 2.5 mm2 (AWG 13)
Trigger mechanism material POM plastic Electrostatic shielding not required
-35 °C to +60 °C
Operating temperature
(-31 °F to +140 °F) Note
Relative humidity 0 to 95% Strong magnetic fields should be avoided in the vicinity
(IEC 721-3-3) no condensation of the detectors. This MCP uses German labeling.
Specification according to EN 12094-3 For other languages please use the part no. 909032.
2GRU 2 microswitches for 2 zones
Weight 475 g (1.1 lbs) Approvals / marking
135 x 161 x 61 mm (WxHxD)
Dimensions G 209030
5.3 x 6.3 x 2.4 inch (WxHxD) 0786-CPD-20689
The contents of this publication are subject to modifications without notice. All rights reserved.
310-310_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 40
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 manual call point, variable Part no.: 909032

Conventional manual call point for outdoor areas similar to


Technical specifications EN 54-11 and EN 12094-3. Free selection of the detector
Type B, configuration possible (Latching or non-latching contact,
Function
latching or non-latching contact silicone free, special labeling). The order is placed along
Technology Conventional with an additional note on the detector, with order number
and the desired modifications. Production is then performed
Rated voltage 9V
manually. A contract review will be performed in order
Operating voltage 7.6 V - 13.2 V DC to comply with regulations. Operating instructions and
Quiescent current 5 mA (at 9 V) connection notes are included with the detector.
Alarm current 20 mA (at 9 V)
IP rating (EN 60529) IP 66
Included in delivery
Mounting hardware
Enclosure material PC
1 Door key
RAL 3001, red 2 Cable glands M20 x 1.5
RAL 1021, yellow 1 Blanking plug
Colour
RAL 5015, blue
RAL 6002, green
Trigger mechanism material POM plastic
Connection / mounting
Connection cable 2-wire
-35 °C to +60 °C
Operating temperature Recommended cable, standard 747180
(-31 °F to +140 °F)
J-Y(ST)Y-2x2x0.8 mm
Relative humidity 0 to 95% Recommended cable for circuit integrity 907940
(IEC 721-3-3) no condensation JE-H(ST)H E30 2x2x0.8 mm
similar to EN 54-11 Conductor cross-section max. 2.5 mm2 (AWG 13)
Specification according to
and EN 12094-3 Electrostatic shielding not required
Weight approx. 475 g (1.1 lbs)
Note
The contents of this publication are subject to modifications without notice. All rights reserved.

135 x 161 x 61 mm (WxHxD)


Dimensions
5.3 x 6.3 x 2.4 inch (WxHxD) Strong magnetic fields should be avoided in the vicinity
of the detectors.

Approvals / marking
310-310_003 / AI00_2015de

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 41
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100, red Part no.: 918153


Conventional manual call point for outdoor areas similar to
EN 54-11. Applicable for operation on conventional lines of
the fire alarm panels FMZ 4100 and FMZ 5000.
The white inside sign can be replaced with other labels (see
DMX outdoor application, accessories).
In case of order the arbitrary/variable label text it is to be
indicated under „Information for production“.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology Conventional 2 Cable glands M20 x 1.5
1 Blanking plug
Rated voltage 9V
Operating voltage 7.6 V - 13.2 V DC
Connection / mounting
Quiescent current 5 mA (at 9 V)
Connection cable 2-wire
Alarm current 20 mA (at 9 V) Recommended cable, standard 747180
IP rating (EN 60529) IP 66 J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity 907940
Enclosure material PC
JE-H(ST)H E30 2x2x0.8 mm
Colour RAL 3001, red Conductor cross-section max. 2.5 mm2 (AWG 13)
Trigger mechanism material POM plastic Electrostatic shielding not required
- 35 °C to +60 °C
Operating temperature
(-31 °F to +140 °F) Note
Relative humidity 0 to 95% Strong magnetic fields should be avoided in the vicinity
(IEC 721-3-3) no condensation of the detectors.
Weight 475 g (1.1 lbs)

Dimensions
135 x 161 x 61 mm (WxHxD) Excerpt from label texts
5.3 x 6.3 x 2.4 inch (WxHxD)
Drucktext Sprache Deutsche
Übersetzung
FEUERALARM deutsch Feueralarm
Approvals / marking FEUERWEHR deutsch Feuerwehr

FIRE ALARM englisch Feueralarm


The contents of this publication are subject to modifications without notice. All rights reserved.

ALARMA DE INCENDIO spanisch Feueralarm

ALARME INCENDIE französisch (Brand-) Feueralarm


ALARME FEU französisch Feueralarm

ALLARME ANTINCENDIO italienisch Feueralarm

HANDMELDER holländisch Handmelder

POŻAR polnisch Feueralarm

POŽIARNY POPLACH slowakisch Feueralarm

‫إﻧﺬار اﻟﺤﺮﻳﻖ‬ arabisch Feueralarm

FIRE ALARM engl./arab. Feueralarm


‫إﻧﺬار اﻟﺤﺮﻳﻖ‬
310-310_004 / AI00_2015en

POŽIARNY POPLACH slowak./engl. Feueralarm


FIRE ALARM

1/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 42
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 manual release, yellow Part no.: 918154

Technical specifications In case of order the arbitrary/variable label text it is


to be indicated under „Information for production“
Function Type B, latching contact
(see excerpt from label texts).
Colour similar to RAL 1021, yellow

Otherwise like part no.: 918153


Excerpt from label texts
Drucktext Sprache Deutsche /engl.
Übersetzung Drucktext Sprache Deutsche /engl.
HANDAUSLÖSUNG deutsch Handauslösung Übersetzung
HANDAUSLÖSUNG - Löschanlage deutsch Handauslösung - Löschanlage WATER RELEASE engl./arab. Wasserauslösung
LÖSCHANLAGE deutsch Löschanlage ‫إﻃﻼق اﻟﻤﻴﺎﻩ‬
GAS RELEASE engl./arab. Gasauslösung
MANUAL RELEASE englisch Handauslösung
CO2 RELEASE englisch CO2-Auslösung
‫إﻃﻼق اﻟﻐﺎز‬
CO2 MANUAL RELEASE englisch CO2 Handauslösung FOAM RELEASE engl./arab. Schaumauslösung
WATER RELEASE englisch Wasserauslösung ‫إﻃﻼق اﻟﺮﻏﻮﻩ‬
GAS RELEASE englisch Gasauslösung FOAM MONITOR RELEASE engl./arab. Foam Monitor Release
DELUGE MANUAL RELEASE englisch Sprühflut Handauslösung ‫ﻣﺮاﻗﺐ إﻃﻼق اﻟﺮﻏﻮﻩ‬
DISPARO MANUAL spanisch Handauslösung
FOAM INJECTION engl./arab. Foam Injection
‫ﺣﻘﻦ اﻟﺮﻏﻮﻩ‬
COMMANDE MANUELLE französisch Handauslösung FOAM DYKE engl./arab. Foam Dyke
DECLENCHEMENT MANUEL französisch Handauslösung ‫ﺣﺎﺟﺰ اﻟﺮﻏﻮﻩ‬
DECLENCHEMENT CO2 französisch CO2 Auslösung
MANUAL RELEASE engl./russ. Handauslösung
RILASCIO MANUALE italienisch Handauslösung
PУЧНOЙ ПУCК
BLUSSING holländisch Löschung
HAND ACTIVERING holländisch Manuelle Löschung CO2 RUČNÉ SPUSTENIE slowak./engl. CO2-Handauslösung
MANUELE BEDIENING holländisch Manuelle Bedienung CO2 MANUAL RELEASE
BEDIENING BLUSINSTALLATIE holländisch Bedienung Löschen
SPROEIVLOED holländisch Löschmittel Zufuhr RUČNÉ SPUSTENIE DELUZNE slowak./engl. Sprühflut Handauslösung
DELUGE MANUAL RELEASE
DECLANŞARE MANUALĂ rumänisch Handauslösung

RUČNÉ SPUSTENIE slowakisch Handauslösung


CO2 RUČNÉ SPUSTENIE slowakisch CO2 Handauslösung
RUČNÉ SPUSTENIE DELUZNE slowakisch Sprühflut Handauslösung Approvals / marking
arabisch Handauslösung
‫إﻃﻼق ﻳﺪوي‬
The contents of this publication are subject to modifications without notice. All rights reserved.

arabisch Wasserauslösung
‫إﻃﻼق اﻟﻤﻴﺎﻩ‬
arabisch Gasauslösung
‫إﻃﻼق اﻟﻐﺎز‬
arabisch Schaumauslösung
‫إﻃﻼق اﻟﺮﻏﻮﻩ‬
arabisch Foam Monitor Release
‫ﻣﺮاﻗﺐ إﻃﻼق اﻟﺮﻏﻮﻩ‬
arabisch Foam Injection
‫ﺣﻘﻦ اﻟﺮﻏﻮﻩ‬
arabisch Foam Dyke
‫ﺣﺎﺟﺰ اﻟﺮﻏﻮﻩ‬
MANUAL RELEASE engl./arab. Handauslösung
‫إﻃﻼق ﻳﺪوي‬

CO2 RUČNÉ SPUSTENIE slowak./engl. CO2-Handauslösung


CO2 MANUAL RELEASE
310-310_004 / AI00_2015en

RUČNÉ SPUSTENIE DELUZNE slowak./engl. Sprühflut Handauslösung


DELUGE MANUAL RELEASE

2/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 43
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional

DMX3100 2nd release, green Part no.: 918156


In case of order the arbitrary/variable label text it is
Technical specifications to be indicated under „Information for production“
Function Type B, non-latching contact (see excerpt from label texts).
Otherwise like part no.: 918153
Colour similar to RAL 6002, green

Excerpt from label texts


Approvals / marking
Drucktext Sprache Deutsche
Übersetzung
NACHLÖSCHEN deutsch Nachlöschen
NACHFLUTEN - Gaslöschanlage deutsch NACHFLUTEN - Gaslöschanlage
2-te AUSLÖSUNG deutsch 2-te Auslösung
2-te LÖSCHAUSLÖSUNG deutsch 2-te Löschauslösung

2nd RELEASE englisch 2-te Auslösung


2nd EXT. RELEASE englisch 2-te Löschauslösung

STINGERE SUPLIMENTARĂ rumänisch Nachlöschen

CO2 DOHASENIE slowakisch CO2 Nachlöschen


DOHASENIE slowakisch Nachlöschen

DOHASENIE slowak./engl. Nachlöschen


SECOND DISCHARGE

DMX3100 emergency button, blue Part no.: 918155


In case of order the arbitrary/variable label text it is
Technical specifications to be indicated under „Information for production“
(see excerpt from label texts).
Function Type B, non-latching contact
Otherwise like part no.: 918153
Colour similar to RAL 5015, blue
Excerpt from label texts
Drucktext Sprache Deutsche / engl.
Übersetzung Drucktext Sprache Deutsche / engl.
AVARINIS STABDYMAS litauisch EMERGENCY STOP Übersetzung
Gesinimo dujomis sistema Gas extinguishing system LÖSCHVERZUG deutsch Löschverzug
The contents of this publication are subject to modifications without notice. All rights reserved.

HAUSALARM deutsch Hausalarm


STOP - AVĀRIJAS IZSLĒGŠANA lettisch STOPP-TASTER - Gaslöschanlage STOPP-TASTER Gaslöschanlage deutsch STOPP-TASTER - Gaslöschanlage
Dzēšanas sistēma ar gāzi HANDBRANDMELDER deutsch Handbrandmelder

EMERGENCY STOP englisch STOPP-TASTER - Gaslöschanlage


HÄTÄPYSÄYTYS – finnisch STOPP-TASTER - Gaslöschanlage Gas extinguishing system
Kaasusammutuslaitteistot EXTINGUISHING DELAY englisch Löschverzug

NÖDSTOPP – schwedisch STOPP-TASTER - Gaslöschanlage PARO DE EMERGENCIA – spanisch STOPP-TASTER - Gaslöschanlage


Gassläcksystem Sistema de extinction por gas
RETARDO DE DESCARGA spanisch Löschverzug
ΔIAKOΠTHΣ EKTAKTHΣ ANAΓKHΣ – griechisch STOPP-TASTER - Gaslöschanlage
Συστημα κατασβεσης με αεριο ARRET D'URGENCE – französisch STOPP-TASTER - Gaslöschanlage
Système d'extinction à gaz
CO2 CTOП russisch CO2-Stopp RETARDEMENT D'EXTINCTION GAZ französisch Löschverzug

arabisch Löschverzug ARRESTO DI EMERGENZA – italienisch STOPP-TASTER - Gaslöschanlage


‫ﺗﺄﺧﻴﺮ اﻹﻃﻔﺎء‬ Impianto di estinzione a gas
ARRESTO CO2 italienisch CO2-Stopp
310-310_004 / AI00_2015en

EXTINGUISHING DELAY engl./arab. Löschverzug NOODSTOP – holländisch STOPP-TASTER - Gaslöschanlage


‫ﺗﺄﺧﻴﺮ اﻹﻃﻔﺎء‬ Blusgas installatie
UITSTEL BLUSSING holländisch Löschung aus
АВАРИЙНО СПИРАНЕ bulgarisch STOPP-TASTER - Gaslöschanlage
Инсталация эа гасене с газообраэно
вещество Approvals / marking

3/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 44
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable, Ex

KAX95 Ex manual call point, red Part no.: 901321


Analogue addressable manual call point for outdoor use in
Ex zone 0 and 20. Provided for use on fire alarm control
units with Loop AP protocol. Addressing via DIP switch, the
address can also be modified after installation. Detector with
intrinsically safe electronics for operation in areas with a risk
of explosion. Connection only via an Ex Loop AP 24 V Ex
security barrier. Markings or labels which do not comply with
the standard will void the EN 54-11 approval.

Included in delivery
Technical specifications
1 Key to reset / open the MCP
Function Type A, latching contact
Technology / protocol Loop AP / XP95 Connection / mounting
Integrated Connection cable 2-wire
no
short circuit isolator Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 14 V - 22 V DC Electrostatic shielding not required
Operating current 300 μA
Alarm display 1 LED, red Note
IP rating (EN 60529) IP 67 Analogue addressable detectors for explosive areas are
to be used in the Loop AP branch. For this purpose the
Enclosure material Polycarbonate /ABS protocol interface is to be used.
Colour red

Operating temperature, T4
-20 °C to +60 °C Connection diagram
(-4 °F to +140 °F)
-20 °C to +40 °C
Operating temperature, T5
(-4 °F to +104 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Weight approx. 240 g (0.53 lbs)
97.5 x 93 x 71 mm (WxHxD)
Dimensions
3.8 x 3.7 x 2.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
x II 1D Ex ia IIIC T135°C Da (-20°C ≤ Ta ≤ +60°C)
Examination certificate: BAS 02 ATEX 1290

0786-CPD-0812
310-330_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 45
Product Sheet | Detecon

Manual call points


DMX outdoor application, addressable, Ex

KAX95 Ex manual call point, yellow Part no.: 912581


Analogue addressable manual call point for outdoor use in
Ex zone 0 and 20. Provided for use on fire alarm control
units with Loop AP protocol. Addressing via DIP switch,
the address can also be modified after installation.
Detector with intrinsically safe electronics for operation in
areas with a risk of explosion. Connection only via an Ex
Loop AP 24 V Ex security barrier.

Included in delivery
Technical specifications
1 Key to reset / open the MCP
Function Type A, latching contact
Technology / protocol Loop AP / XP95 Connection / mounting
Integrated Connection cable 2-wire
no
short circuit isolator Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 14 V - 22 V DC Electrostatic shielding not required
Operating current 300 μA
Alarm display 1 LED, red Note
IP rating (EN 60529) IP 67 Analogue addressable detectors for explosive areas
are to be used in the Loop AP branch. For this purpose
Enclosure material Polycarbonate /ABS the protocol interface is to be used.
Colour yellow

Operating temperature, T4
-20 °C to +60 °C Connection diagram
(-4 °F to +140 °F)
-20 °C to +40 °C
Operating temperature, T5
(-4 °F to +104 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Weight approx. 240 g (0.53 lbs)
97.5 x 93 x 71 mm (WxHxD)
Dimensions
3.8 x 3.7 x 2.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
x II 1D Ex ia IIIC T135°C Da (-20°C ≤ Ta ≤ +60°C)
Examination certificate: BAS 02 ATEX 1290
310-330_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 46
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional, Ex

dC 31 manual call point, red Part no.: 908711


Conventional manual call point for outdoor areas in Ex
zone 1 and 21 in accordance with EN 54-11. Designed
for operation on conventional lines of the fire alarm panels
FMZ 4100 and FMZ 5000. The white inside sign can be
replaced with other labels (see DMX outdoor application,
accessories). Markings or labels which do not comply with
the standard will void the VdS and EN 54-11 approvals.

Included in delivery
Technical specifications
Mounting hardware
Function Type B, latching contact 1 Door key
Technology Conventional 2 Cable glands M20 x 1.5
1 Blanking plug
Rated voltage 9V
Operating voltage 7.6 V - 9.7 V DC
Connection / mounting
Quiescent current 5 mA (at 9 V)
Connection cable 2-wire
Alarm current 20 mA (at 9 V) Recommended cable, standard 747180
IP rating (EN 60529) IP 66 J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity 907940
Enclosure material PC
JE-H(ST)H E30 2x2x0.8 mm
Colour RAL 3001, red Conductor cross-section max. 2.5 mm2 (AWG 13)
Trigger mechanism material POM plastic Electrostatic shielding not required
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F) Note
-35 °C to +60 °C An Ex barrier and the blue fire alarm cable are not required.
Storage temperature
(-31 °F to +140 °F) Strong magnetic fields should be avoided in the vicinity of the
Relative humidity 0 to 95% detectors.
(IEC 721-3-3) no condensation
Specification according to EN 54-11 Approvals / marking
Ex zones 1 (Gas) and 21 (Dust) Ex conformity in acc. with 94/9/EC
Weight 475 g (1.1 lbs) x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
135 x 161 x 61 mm (WxHxD)
Dimensions Examination certificate: BVS 09 ATEX E016 X
The contents of this publication are subject to modifications without notice. All rights reserved.

5.3 x 6.3 x 2.4 inch (WxHxD)

G 206113 0786-CPD-20309
310-330_003 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 47
Product Sheet | Detecon

Manual call points


DMX outdoor application, conventional, Ex

dC31 manual release, yellow Part no.: 908712

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EC
Function Type B, latching contact
x II 2G Ex emb IIC T6 Gb
Colour RAL 1021, yellow x II 2D Ex tb IIIC T80°C Db
Specification according to EN 12094-3 Examination certificate: BVS 09 ATEX E016 X

Otherwise like part no. 908711 G 207079 0786-CPD-20310

Markings or labels which do not comply with the standard Note


will void the VdS and EN 12094-3 approvals. Please select the label text of the MCP when ordering

dC31 emergency button, blue Part no.: 908713

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EC
Function Type B, non-latching contact
x II 2G Ex emb IIC T6 Gb
Colour RAL 5015, blue x II 2D Ex tb IIIC T80°C Db
Specification according to EN 12094-3 Examination certificate: BVS 09 ATEX E016 X

G 207099 0786-CPD-20311
Otherwise like part no. 908711

Markings or labels which do not comply with the standard will Note
void the VdS and EN 12094-3 approvals. Please select the label text of the MCP when ordering
The contents of this publication are subject to modifications without notice. All rights reserved.

dC31 2nd release, green Part no.: 908714

The outside sign is as specified by VdS 2496 Issue 12.96.


Technical specifications
Function Type B, non-latching contact Approvals / marking
Colour RAL 6002, green Ex conformity in acc. with 94/9/EC
Specification according to similar to EN 12094-3
x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
Examination certificate: BVS 09 ATEX E016 X
Otherwise like part no. 908711
G 207099
Markings or labels which do not comply with the standard will
310-330_003 / AI00_2015en

void the VdS approval.


Note
Please select the label text of the MCP when ordering.

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 48
Product Sheet | Detecon

Manual call points


DMX outdoor application, accessories

DMX3100 SUX95 card, switch Part no.: 907890

DMX3100 SUX95 card, button Part no.: 907912

DMX3100 card, switch Part no.: 907883

DMX3100 card, button Part no.: 907884

DMX3100 card, 2GRU, switch Part no.: 907887

DMX3100 card, ZPD, switch Part no.: 907886

DMX3100 SUX50 card, switch Part no.: 907889

Special labeling for white inside panel, Part no.: 907192


complete
The contents of this publication are subject to modifications without notice. All rights reserved.
310-340_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 49
Product Sheet | Detecon

Manual call points


DMX accessories, general

"D" shape door key Part no.: 173881

Replacement glass pane, clear Part no.: 903563


The contents of this publication are subject to modifications without notice. All rights reserved.
310-940_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 4 - 50
Product Sheet | Detecon

Standard detectors
General information

Loop detectors and modules


The detector series offers ionisation smoke detectors,
optical smoke detectors, heat detectors and multisensor
detectors, communicating with the FMZ 5000 with a Loop AP
module. The series is supplemented by manual call points,
modules, isolators and other loop nodes.
Every product responds to queries and control commands
from the fire alarm panels. It communicates with the fire
alarm panel about the status, type and position as well as
external commands and other information contributing to
the alarm status. The signals are also checked for errors.
For some detectors five different operating modes are
available which can be selected via the fire alarm panel.
Each operating mode has a specific response behaviour
which corresponds to the fire criteria to be expected.

Conventional detectors
Conventional detectors with a wide range of supply voltages.

The interactive loop detectors define a new standard in reliable fire detection. Highly developed
software algorithms and strongly expanded functionalities set new standards. Fire characteristics
are selected in such a way that a fire will be safely detected.
The various options for the individual adjustment of the detector sensitivity and several setup modes
dependent on the time of day guarantee the optimum detector adjustment to the area being monitored.

With these performance characteristics all safety concepts can be implemented and ensure maximum customer benefit:
• Five detector sensitivity stages/algorithms for each application (for the standard loop detectors)
• Detector sensitivity that can be switched according to environmental conditions depending on the time of day
(for the standard loop detectors)
• Automatic drift compensation of the measuring system for constant sensitivity over the whole period of application
• Automatic contamination detection and early maintenance indication for the efficient deployment of maintenance personnel
• Automatic function monitoring including sensor technology for greatest availability
The contents of this publication are subject to modifications without notice. All rights reserved.

• Safe operation due to emergency running characteristics during a potential processor failure
• Non-volatile memory, e.g. date of commissioning, last service, reference number, value of the drift compensation

A variety of detector installation bases and numerous modules for adding contacts and issuing signals complete this system.
Visual and acoustic signal transmitters can also be switched directly on the loop to issue alarms.
311-010_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 1
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, addressable

Optical smoke detector OMX95 Part no.: 907541


Analogue addressable optical smoke detector.
Designed for use in areas where only low false alarm
sources can be expected. Applicable for operation
in fire alarm panel FMZ 5000 with Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address
can also be changed after installation.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base see accessories
software and hardware including the microcontroller Address card 901297
• Non-volatile memory for detector data
• Day/night switching via fire alarm panel with Connection / mounting
different sensitivities Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Technical specifications Electrostatic shielding not required
Detection method Infrared photo diode
Technology / protocol Loop AP / Discovery Sensitivity modes
Integrated isolator no smoke tmin alarm
Operating voltage 17 V - 28 V DC 1 1.4 % / m (39.4 inch) 5s
Quiescent current 0.44 mA 2 1.4 % / m (39.4 inch) 30 s
Alarm current 3.4 mA 3 2.1 % / m (39.4 inch) 5s
Alarm indication 2 red LEDs 4 2.1 % / m (39.4 inch) 30 s
-40 °C to +70 °C 5 2.8 % / m (39.4 inch) 5s
Operating temperature
(-40 °F to 158 °F)
IP rating (EN 60529) IP 44
Note
Enclosure material white polycarbonate
The response sensitivity must be adjusted to the environmental
Relative humidity 0 to 95% conditions. The settings can be changed at any time.
(IEC 721-3-3) no condensation
The contents of this publication are subject to modifications without notice. All rights reserved.

Specification according to EN 54 Part 7


Approvals / marking
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H) G 208033 0832-CPD-0024
Dimensions
3.9 x 1.7 inch (dia.xH)
311-120_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 2
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, addressable

Ionisation smoke detector IMX95 Part no.: 907544


Analogue addressable ionisation smoke detector.
Designed for use in areas where occasional low dust can
be expected. Applicable for operation in fire alarm panel
FMZ 5000 with Loop AP protocol. 5 sensitivity modes,
adjustable via software control. Addressing via separate
address card. The address can also be changed after
installation.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base see accessories
software and hardware including the microcontroller Address card 901297

• Non-volatile memory for detector data


Connection / mounting
• Day/night switching via fire alarm panel
with different sensitivities Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Technical specifications Electrostatic shielding not required

Detection method Ionisation chamber


Sensitivity modes
Technology / protocol Loop AP / Discovery
Integrated isolator no
Smoke value tmin alarm

Radioactive isotope Americium 241 1 y = 0.45 5s

Radioactivity 33.3 kBq 2 y = 0.45 30 s


Air velocity max. 10 m/s (39.4 inch) 3 y = 0.70 5s
equivalent to 600 m (0.37 miles) 4 y = 0.70 30 s
Atmospheric pressure
above MSL max. 5 y = 1.00 5s
Operating voltage 17 V - 28 V DC
Quiescent current 0.38 mA Note
Alarm current 3.4 mA The response sensitivity must be adjusted to the
Alarm indication 2 red LEDs environmental conditions. The settings can be changed
at any time. The detector contains radioactive materials.
The contents of this publication are subject to modifications without notice. All rights reserved.

-30 °C to +70 °C
Operating temperature The operating instructions and current laws and relating to
(-22°F to +158 °F)
radiation protection must be observed.
IP rating (EN 60529) IP 44
Enclosure material white polycarbonate
Approvals / marking
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
G 208036 0832-CPD-0023
Specification according to EN 54 Part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H)
Dimensions
3.9 x 1.7 inch (dia. x H)
311-170_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 3
Product Sheet | Detecon

Standard detectors
Multisensor detectors, addressable

Multisensor detector OWMX95 Part no.: 907543


Analogue addressable multisensor detector consisting
of a combination of an optical smoke detector and a heat
detector. Designed for use in areas where regular false
alarm sources can be expected. Intended for operation
in fire alarm panel FMZ 5000 with Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address
can also be changed after installation.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base see accessories
software and hardware including the microcontroller Address card  901297

• Non-volatile memory for detector data


• Day/night switching via fire alarm panel Connection / mounting
with different sensitivities Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Technical specifications Electrostatic shielding not required
Smoke detection method Infrared photo diode
Heat detection method NTC temperature sensor Sensitivity modes
Technology / protocol Loop AP / Discovery Smoke Heat Trigger type tminAlarm
Integrated isolator no 1.1 % / m
1 high Multisensor 20 s
(39 inch)
Operating voltage 17 V - 28 V DC
2.1 % / m no
Quiescent current 0.47 mA 2 Optical 30 s
(39 inch) response
Alarm current 3.5 mA
2.8 % / m
Alarm indication 2 red LEDs 3 low Multisensor 20 s
(39 inch)
-30 °C to +70 °C 4.2 % / m
Operating temperature 4 high Multisensor 20 s
(-22 °F to +158 °F) (39 inch)
IP rating (EN 60529) IP 44
A1
5 no response A1 class 30 s
Enclosure material white polycarbonate heat detector
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity 0 to 95%


(IEC 721-3-3) no condensation
Note
Specification according to EN 54 part 5 and 7
The response sensitivity must be adjusted to the ambient
Weight 105 g (0.2 lbs) conditions. The settings can be changed at any time.
100 x 50 mm (dia. x H) When using the detector in mode 5 the number of max.
Dimensions permitted monitoring areas for heat detectors must not be
3.9 x 2 inch (dia.xH)
exceeded.

Approvals / marking

G 208034 0832-CPD-0025
311-520_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 4
Product Sheet | Detecon

Standard detectors
Heat detectors, addressable

Heat detector WMX95 Part no.: 907542


Analogue addressable rate-of-rise and maximum heat
detector for use in areas where interference variables like
smoke can be expected (e.g. office/storage areas, industrial
plants or test stands). Applicable for operation in fire alarm
panels FMZ 5000 with Loop AP protocol.
3 response classes in accordance with EN 54-5 and
2 temperature ranges adjustable via software control.
Addressing via separate address card.
The address can also be changed after installation.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base see accessories
software and hardware including the microcontroller Address card 901297

• Non-volatile memory for detector data


Connection / mounting
• Day/night switching via fire alarm panel
Connection cable 2-wire
with different sensitivities
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (AWG 13)
Technical specifications Electrostatic shielding not required

Detection method NTC temperature sensor


Sensitivity modes
Technology / protocol Loop AP / Discovery
Class Temperature
Integrated isolator no
1 A1R 54 °C (129 °F) to 65 °C (149 °F)
Response classes A1R, A2, A2S
Temperature ranges CR, CS
2 A2 54 °C (129 °F) to 70 °C (158 °F)

Operating voltage 17 V - 28 V DC
3 A2S 54 °C (129 °F) to 70 °C (158 °F)

Quiescent current 0.35 mA


4 CR 84 °C (129 °F) to 100 °C (212 °F)

Alarm current 3.4 mA 5 CS 84 °C (129 °F) to 100 °C (212 °F)

Alarm indication 2 red LEDs


+54 °C to +100 °C Note
Response temperature
(+129.2 °F to +212 °F) The response sensitivity must be adjusted to the environmental
-40 °C to +80 °C conditions. The settings can be changed at any time.
Operating temperature
(-40 °F to +176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 54


Approvals / marking
Enclosure material white polycarbonate
Relative humidity 0 to 95%
G 208035 0832-CPD-0022
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 105 g (0.2 lbs)
100 x 42 mm (dia. x H)
Dimensions
3.9 x 1.7 inch (dia. x H)
311-220_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 5
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Detector base BAX 210 Part no.: 901289


Base for all Loop AP detectors including address card
with large-size contact screws for all connections.
Easy assembly and simple insertion of the detectors
by clockwise rotation and lock. A terminal for a detector
remote indicator is available.

Included in delivery
1 detector base in standard design
including address card 1 to 126

Not included in delivery


Mounting hardware

Technical specifications
Approvals / marking
Material PC
Integrated isolator no
Colour white
-20 °C to +70 °C
Ambient temperature
(-4 °F to +158 °F)
Weight 55 g (0.1 lbs)
100 x 8 mm (dia. x H)
Dimensions
3.9 x 0.3 inch (dia. x H)

Detector base BAX 284 I Part no.: 910790


Base for all Loop AP detectors including address card
with dual isolator and large-size contact screws for all
connections. For the separation of individual line sections
in the event of short circuits in loop operation.
Easy assembly and simple insertion of the detectors
by clockwise rotation and lock. A terminal for a detector
remote indicator is available.

Included in delivery
1 detector base in standard design
including address card 1 to 126
The contents of this publication are subject to modifications without notice. All rights reserved.

Not included in delivery


Mounting hardware
Technical specifications
Material PC Approvals / marking
Integrated isolator yes
Fault indication yellow LED G 210033 0832-CPD-1011
Colour white
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
311-720_001 / AI01_2016en

Weight 100 g (0.2 lbs)


100 x 24 mm (dia. x H)
Dimensions
3.9 x 0.9 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 6
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Isolator base BAX 211 Part no.: 901294


Base for the ISX 720 I isolator with large-size contact
screws for all connections. Easy assembly and simple
insertion of the isolator by clockwise rotation and lock.

Included in delivery
1 Isolator base in standard design

Not included in delivery


Mounting hardware
Isolator ISX 720 901293

Approvals / marking
Technical specifications
Material PC
Colour white
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
Weight 55 g (0.1 lbs)
100 x 23 mm (dia. x H)
Dimensions
3.9 x 0.9 inch (dia. x H)

Isolator ISX 720 I Part no.: 901293


Loop AP isolator for the separation of individual line
sections in the event of short circuits in loop operation.
Easy assembly and simple insertion of the isolator in the
matching base by means of clockwise rotation and lock.

Included in delivery
1 Isolator for use in isolator base BAX 211

Approvals / marking

G 200083 0832-CPD-0843
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Material PC
Fault indication yellow LED
IP rating (EN 60529) IP 43
Colour white
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
Weight 75 g (0.2 lbs)
311-720_002 / AI01_2016en

100 x 25 mm (dia. x H)
Dimensions
3.9 x 1 inch(dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 7
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Isolator ISX 284 R Part no.: 914137


Loop AP isolator for the separation of individual line
sections in the event of short circuits in loop operation.
Easy assembly for mounting on a mounting rail.

Included in delivery
1 isolator for mounting on a mounting rail

Approvals / marking

Technical specifications
Fault indication yellow LED
- 20 °C to + 60 °C
Ambient temperatur
(-4 °F to +140 °F)
Weight 20 g
Dimensions 63 x 38.8 x 43 mm (BxHxT)

Bypass detector BMX1001 AP Part no.: 908689


The BMX1001 bypass box for intake an analogue
addressable optical smoke detector OMX95 to monitor
exhaust air and air conditioning ducts with higher air speeds.

Not included in delivery


Optical smoke detector OMX95 907541
Loctite AVK 586, bottle 50 ml  886226
Assembly tool for rivet nuts

Connection / mounting
Recommended cable  J-Y (St) Y 2x2x0.8 mm, red

Note
Technical specifications VdS approval only for bypass box with optical smoke detector
The contents of this publication are subject to modifications without notice. All rights reserved.

1 m (39 inch)/s to max. OMX95. Approval for the control of fire damper does not exist.
Air flow
20 m (787 inch)/s
Detector slot 1 detector base BAX 284-I Approvals / marking
2 threaded pipes DN15
Pipe for bypass detector
galvanized, 540 mm G 28406
Enclosure material Aluminium diecast, grey
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
IP rating IP 23
Weight with 2 pipes 3500 g (7.7 lbs)
311-720_003 / AI00_2015en

130 x 165 x 95 mm (WxHxD)


Dimensions
5.1 x 6.5 x 3.7 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 8
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable

Isolator XP95 IP 65, complete Part no.: 905702


Isolator for the separation of individual line sections
during short circuit in loop AP in robust design.
Easy assembly and simple insertion of the isolator with
base in the additional enclosure for industrial applications.

Included in delivery
Technical specifications 1 Abox 100  905711
1 Mounting plate, complete 908422
Material PC 1 Isolator ISX 720  901293
IP rating (EN 60529) IP 65 1 Isolator base BAX 211  901294
Colour of lower
enclosure section grey Not included in delivery
Colour of upper
enclosure section red Mounting hardware
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
Weight 340 g (0.8 lbs)
140 x 140 x 70 mm (WxHxD)
Dimensions
5.5 x 5.5 x 2.8 inch (WxHxD)

Addressing card ACX 771 Part no.: 901297


Address cards for detectors type XP and DIS, unlabelled,
100 pcs per packaging unit

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.
311-720_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 9
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, addressable, Ex

Optical smoke detector OMX95 Ex Part no.: 901318


Analogue addressable optical smoke detector for Ex zone 0
designed for use in hazard areas where only low false alarm
sources can be expected. Provided for operation on fire
alarm control panels FMZ 5000 with Loop AP protocol.
Addressing by means of separate address card.
The address can also be changed after installation.
Detector with intrinsically safe electronics for operation in
areas hazard. Connection only via a safety barrier Ex Loop
AP 24 V and a protocol interface Loop AP.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base  see accessories
software and hardware including the microcontroller Address card  901297
Safety barrier Ex Loop AP 24 V 901324
• Detector for use in zone 0 Protocol interface Loop AP 901322

Connection / mounting
Technical specifications Connection cable  2-wire
Detection method Infrared photo diode
Recommended cable 747180
J-Y(ST)Y-2x2x0.8 mm
Technology / protocol Loop AP / XP95 Conductor cross-section max. 2.5 mm2 (AWG 13)
Integrated isolator no Electrostatic shielding not required
Operating voltage 14 V - 22 V DC
Quiescent current 0.34 mA Note
Alarm current 1.34 mA Analogue addressable detectors for hazard areas are to be
connected to a spur of the Loop AP. The protocol interface
-20 °C to + 60 °C
Operating temperature, T4
(-4 °F to +140 °F)
and the safety barrier Ex Loop AP have to be used.

-20 °C to +40 °C
Operating temperature, T5
(-4 °F to +104 °F) Approvals / marking
Enclosure material white polycarbonate Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
Specification to EN 54 part 7
EC type approval certificate: BAS 02 ATEX 1289
Weight 105 g (0.2 lbs) Ex conformity Russia in acc. with TP TC 012/2011:
The contents of this publication are subject to modifications without notice. All rights reserved.

100 x 42 mm (DxH) 0Ex ia IIC T5/T4 Ga


Dimensions
3.9 x 1.7 inch (DxH)

0832-CPD-0313
311-130_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 10
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, addressable, Ex

Ionisation smoke detector IMX95 Ex Part no.: 901317


Analogue addressable ionisation smoke detector for Ex
zone 0 designed for use in areas where occasionally low dust
can be expected. Provided for use on FMZ 5000 fire alarm
control panels with Loop AP protocol. Addressing via
separate address card. The address can also be changed
after installation. Detector with intrinsically safe electronics for
operation in hazard areas. Connection only via an Ex Loop
AP 24 V safety barrier and a protocol interface Loop AP.

Product features Not included in delivery


• Constant function monitoring of the sensors, software Detector base  see accessories
and hardware including the microcontroller Address card  901297
Safety barrier Ex standard  901324
• Detector for use in zone 0 Loop AP protocol interface 901322

Connection / mounting
Technical specifications Connection cable  2-wire
Detection method Ionization chamber
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technology / protocol Loop AP / XP95 Conducter cross-section max. 2.5 mm2 (AWG 13)
Integrated isolator no Electrostatic shielding not required
Radioactive isotope Americium 241
Radioactivity 33.3 kBq Note
Air speeds max. 10 m (394 inch)/s Analogue addressable detectors for hazard areas are to be
connected to a spur of the Loop AP. The protocol interface
corresponding to max. 600 m
Atmospheric pressure
(0.37 miles) a.s.l.
and the safety barrier Ex Loop AP have to be used.

Operating voltage 14 V - 22 V DC
Quiescent current 0.3 mA
Approvals / marking
Ex conformity in acc. with 94/9/EG
Alarm indication 1 LED red
x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
Operating temperature, T4
-20 °C to +60 °C x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
(-4 °F to +140 °F)
-20 °C to +40 °C EC type approval certificate: BAS 02 ATEX 1289
Operating temperature, T5
(-4 °F to +104 °F) Ex conformity Russia in acc. with TP TC 012/2011:
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material white polycarbonate 0Ex ia IIC T5/T4 Ga


Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
0832-CPD-0312
Specification according to EN 54 Part 7
Weight 105 g (0.2 lbs)
100 x 42 mm (DxH)
Dimensions
3.9 x 1.7 inch (DxH)
311-180_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 11
Product Sheet | Detecon

Standard detectors
Heat detectors, addressable, Ex

Heat detector WMX95 Ex Part no.: 901319


Analogue addressable maximumand rate-of-rise heat
detector for Ex zone 0 for use in areas in which interferance
such as smoke are likely to be encountered (e.g. office- and
storage areas, industrial plant or test facilities). Provided for
use on FMZ 5000 fire alarm control panels with Loop AP
protocol.
Addressing via separate address card. The address can
also be changed after installation. Detector with intrinsically
safe electronics for operation in areas hazard.
Connection only via an Ex Loop AP 24 V safety barrier
and a protocol interface Loop AP.

Product fearures Not included in delivery


• Constant function monitoring of the sensors, software Detector base see accessories
and hardware including the microcontroller Address card  901297
Safety barrier Ex standard  901324
• Detector for use in Zone 0 Loop AP protocol interface 901322

Connection / mounting
Technical specifications Connection cable  2-wire
Detection method NTC-temperature sensor
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Technology / protocol Loop AP / XP95 Conductor cross-section max. 2.5 mm2 (AWG 13)
Integrated isolator no Electrostatic shielding not required
Operating voltage 14 V - 22 V DC
Quiescent current 0.3 mA Note
Alarm current 1.3 mA Analogue addressable detectors for hazard areas are to be
connected to a spur of the Loop AP. The protocol interface
Alarm indication 1 LED red and Ex Loop AP safety barrier have to be used.
Activating temperature approx. +60 °C (+140 °F)
-20 °C to +60 °C Approvals / marking
Operating temperature, T4
(-4 °F to +140 °F)
Ex conformity in acc. with 94/9/EG
Operating temperature, T5
-20 °C to +40 °C x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
(-4 °F to +104 °F)
x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
Enclosure material white polycarbonate
Relative humidity 0 to 95% EC type approval certificate: BAS 02 ATEX 1289
(IEC 721-3-3) no condensation Ex conformity Russia in acc. with TP TC 012/2011:
The contents of this publication are subject to modifications without notice. All rights reserved.

0Ex ia IIC T5/T4 Ga


Specification according to EN 54 Part 5
Weight 105 g (0.2 lbs)
100 x 42 mm (DxH) 0832-CPD-0311
Dimensions
3.9 x 1.7 inch (DxH)
311-230_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 12
Product Sheet | Detecon

Standard detectors
Detector accessories, addressable, Ex

Detector base BAX 215 Ex Part no.: 901320


Base for all analogue addressable Ex-detectors including
address card with large size contact screws for all
connections. Simple mounting and easy insertion of
detectors by clockwise rotation and lock. Base for use in
areas with a risk of explosion.
Connection only via an Ex Loop AP 24 V Ex safety barrier
and protocol interface Loop AP.

Included in delivery
1 Detector base in the standard version
incl. address card from 1 to 126

Not included in delivery


Technical specifications Mounting materials
Material PC
Integrated isolator no Approvals / marking
Colour white Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +45°C)
-20 °C to +60 °C
Operating temperature, T4
(-4 °F to +140 °F) x II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +60°C)
-20 °C to + 45 °C
Operating temperature, T5 EC type approval certificate: BAS 02 ATEX 1289
(-4 °F to +113 °F)
Weight 55 g (0.1 lbs)
100 x 8 mm (DxH)
Dimensions
3.9 x 0.3 inch (DxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-730_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 13
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional

Optical smoke detector OMX 1001C Part no.: 800831


Conventional optical smoke detector. Designed for use in
areas with smoke in case of fire. Robust smoke detector with
drift compensation for use in industrial environments.

Product features Not included in delivery


• Constant function monitoring of sensors, Detector base  see accessories
software and hardware including the microcontroller End of line-resistor 1.8 K / 0.5 W 675235
Dust cover  894760
• Normal operation indication by green flashing light
• Automatic drift compensation
Spare parts
• Robust smoke detector Insert OMX (Can)  801023
Basket IMX (Dust-proof grid) 253250

Technical specifications Connection / mounting


Detection method Infrared photo diode Connection cable standard detector 2-wire
Remote indication 2-wire
Alarm threshold
approx. 0.16 dB/m (39 inch) Recommended cable JY (St) Y 2x2x0.8 mm
(light obscuration)
Conductor cross-section max. 2.5 mm2 (AWG 13)
Technology conventional
Operating voltage 7.6 V - 13.2 V DC
Approvals / marking
Quiescent current approx. 0.13 mA
Alarm current approx. 18 mA G 200005 0786-CPD-20131
Alarm indication 1 LED red, permanent light
Normal operation indication 1 LED green, flashing light
Electrostatic shielding recommended
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP 43, with membrane plug and


IP rating (EN 60529)
sealing of the mounting holes
Enclosure material white polycarbonate
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54-7
Weight 220 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
311-110_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 14
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, conventional

Ionisation smoke detector IMX 1001E Part no.: 754450


Conventional ionisation smoke detector. Designed for use in
areas with smoke in case of fire. Robust smoke detector with
a dual ionisation chamber for use in industrial environments.

Product features Not included in delivery


• Drift compensation by dual ionization Detector base  see accessories
End of line-resistor 1.8 K / 0.5 W 675235
• Robust smoke detector
Dust cover  894760

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Detection method Double ionization chamber Remote indication  2-wire
Recommended cable  JY (St) Y 2x2x0.8 mm
Technology conventional
Conductor cross-section  max. 2.5 mm2 (AWG 13)
Operating voltage 7.6 V - 13.2 V DC
Quiescent current approx. 0.08 mA Note
Alarm current approx. 20 mA The detector contains radioactive materials. The operating
Alarm indication 1 LED red instructions and current laws and regulations on radiation
protection must be observed.
Sensitivity y = 0.8
Air flow max. 5 m/s
Approvals / marking
Radioactivity Am241 2.8 kBq
Electrostatic shielding recommended
G 28107 0786-CPD-20211
-20 °C up to +60 °C
Operating temperature
(-4 °F to +140 °F)
IP 43, with membrane plug and
IP rating (EN 60529)
sealing of the mounting holes
Enclosure material Polycarbonate white
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 95%


(IEC 721-3-3) avoid condensation
Specification according to EN 54-7
Weight 230 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
311-160_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 15
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

Heat detector WMX 1000D60 Part no.: 747866


Conventional combined rate-of-rise and static heat detector.
Designed for areas with rapid rise of temperature caused by
flames. Robust heat detector with 2 temperature sensors for
use in industrial environments.

Product features Not included in delivery


• Adaptation to ambient temperature Detector base see accessories
by 2 temperature sensors End of line-resistor 1.8 K / 0.5 W 675235
Dust cover 894760
• Combined rate-of-rise and static measurement
• Robust heat detector
Connection / mounting
Connection cable standard detector 2-wire
Remote indication  2-wire
Technical specifications Recommended cable  JY (St) Y 2x2x0.8 mm
Conductor cross-section  max. 2.5 mm2 (AWG 13)
Detection method NTC-temperature sensor
Technology conventional
Approvals / marking
Operating voltage 7.6 V - 13.2 V DC
Quiescent current approx. 0.07 mA
G 27611 0786-CPD-20208
Alarm current approx. 15 mA
Alarm indication 1 LED red
Temperature class, Class A1,
rate of rise measurement acc. to EN 54-5: 2000 / A1:2002
+54 °C to +62 °C
Static threshold value
(+129.2 °F to +143.9 °F)
Electrostatic shielding not required
-20 °C to +50 °C
Operating temperature
(-4 °F to +122 °F)
IP 23, with membrane plug and
IP rating (EN 60529)
The contents of this publication are subject to modifications without notice. All rights reserved.

sealing of the mounting holes


Enclousure material white polycarbonate
Relative humidity max. 95%
(IEC 721-3-3) no condensation
Specification according to EN 54-5
Weight 140 g (0.3 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
311-210_001 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 16
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

Heat detector WMX1000D90 Part no.: 747878

Approvals / marking
Technical specifications
Temperature class, Class C, G 29109 0786-CPD-20209
rate of rise measurement acc. to EN 54-5: 2000 / A1:2002
+84 °C to +100 °C
Static threshold value
(+183.2 °F to +212 °F)
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Weight 140 g (0.3 lbs) Otherwise like part no. 747866
The contents of this publication are subject to modifications without notice. All rights reserved.
311-210_001 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 17
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional

Detector base metric, 3-pin Part no.: 903502


Standard detector base

Not included in delivery


Membrane plug M16x1.5 (side cable entry) 902313
Membrane plug M20 PE (rear cable entry) 902541
End cap white (side cable entry) 795007
End of line-resistor 1.8 K /0.5 W  675235
Mounting materials

Spare parts
Contact blade  761756
Technical specifications Terminal  212400
Enclousure material Polycarbonate Cylinder head screw M4x6 DIN84 237829
Serrated lock washer A4,3 DIN6798 606073
Relative humidity max. 100 %
Colour white
-40 °C to +100 °C
Operating temperature
(-40 °F to +212 °F )
Weight 100 g (0.2 lbs)
113 mm (D)
Dimensions
4.5 inch (D)

Detector base metric, 5-pin Part no.: 903503


Detector base with connection remote indicator.

Not included in delivery


Membrane plug M16x1.5 (side cable entry) 902313
Membrane plug M20 PE (rear cable entry) 902541
End cap white (side cable entry) 795007
End of line-resistor 1.8 K /0.5 W  675235
Mounting materials
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications Spare parts


Contact blade 761756
Enclousure material Polycarbonate
Terminal  212400
Relative humidity max. 100 % Cylinder head screw M4x6 DIN84 237829
Colour white Serrated lock washer A4.3 DIN6798 606073
-40 °C to +100 °C
Operating temperature
(-40 °F to +212 °F )
Weight 100 g (0.2 lbs)
113 mm (D)
Dimensions
4.5 inch (D)
311-710_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 18
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional

Dust cover for white detectors Part no.: 894760


Protection against pollution of the detector OMX1001C
and IMX1001E before commissioning.

Included in delivery
1 Piece (individual delivery)

ote
N
Dust cover to be removed with detector servicing tool

Technical specifications
Enclousure material PVC 0.4 mm (0.01 inch)
Colour orange
Weight 4 g (0.01 lbs)
80.5 x 23 mm (DxH)
Dimensions
3.2 x 0.9 inch (DxH)

Bypass detector BMX1001 Part no.: 719754

The BMX1001 bypass box for the intake of an optical


smoke detector OMX1001C to monitor exhaust air and
air conditioning ducts with higher air speeds.

Not included in delivery


Optical smoke detector OMX1001C 800831
Loctite AVK 586, bottle 50 ml  886226
Assembly tool for rivet nuts

Connection / mounting
Recommended cable  J-Y (St) Y 2x2x0.8 mm, red
Technical specifications
The contents of this publication are subject to modifications without notice. All rights reserved.

Air flow
1 m (39 inch)/s to max. Note
20 m (787 inch)/s VdS approval only for bypass box with optical smoke
Detector slot 1 detector base 5-pin detector OMX1001C. An approval for the control of fire
damper does not exist.
2 threaded pipes DN15
Pipe for bypass detector
galvanized, 540 mm (21.6 inch)
Enclousure material Aluminium diecast, grey Approvals / marking
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F) G 28406
IP rating IP 23
Weight with 2 pipes 3500 g (7.7 lbs)
311-710_002 / AI00_2015en

130 x 165 x 95 mm (BxHxT)


Dimensions
4.5 x 2.7 inch (DxHxT)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 19
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional

Optical smoke detector OMX2151 Part no.: 918417


Conventional optical smoke detector for application in areas
where formation of smoke is to be anticipated in case of fire.

Product features Not included in delivery


• Modern and low-profile design Detector base BAX B110RLP  918421
• 2 LEDs provide 360° visibility in both
standby and alarm modes Connecting / mounting
• Adaptation to the environmental conditions through Connection cable standard detector 2-wire
automatic drift compensation (Connection via detector base)
• Stabile performance in high air velocities
Note
Applicable for operation with the fire alarm panel
FMZ 5000 mod S CA (918493).
Technical specifications
Detection method Infrared photo diode
Approvals / marking
Technology conventional
Operating voltage 8.5 V - 35 V DC
Quiescent current 0.12 mA
Alarm current 10 - 62 mA
Alarm indication 2 LEDs red, steady light
0 °C to +49 °C
Operating temperature
+32 °F to +120.2 °F
Enclosure material PC/ ABS Blend
10 to 93%
Relative humidity
no condensation
Weight 88 g (0.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 157 x 42 mm (DxH)


(installed in detector base) 6.2 x 1.7 inch (DxH)
311-110_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 20
Produktbla | Detekon

Standard detectors
Multisensor detectors, conventional

Multisensor detector OWMX2151T Part no.: 918419


Conventional multisensor detector consisting of a
combination of optical smoke detector and heat detector.

Product features Not included in delivery


• 2 LEDs provide 360° visibility in both Detector base BAX B110RLP 918421
standby and alarm modes
• Adaptation to the environmental conditions through Connecting / mounting
automatic drift compensation Connection cable standard detector 2-wire
• Stabile performance in high air velocities (Connection by detector base)

Note
Technical specifications Applicable for operation with the fire alarm panel
FMZ 5000 mod S CA (918493).
Smoke detection method Infrared photo diode
Heat detection method NTC temperature sensor
Approvals / marking
Technology conventional
Operating voltage 8.5 V - 35 V DC
Quiescent current 0.12 mA
Alarm current 10 - 62 mA
Alarm indication 2 LEDs red, steady light
Operating temperature 0 °C to +38 °C
(according to UL Standard) (+32 °F to +100.4 °F)
Enclosure material PC/ABS Blend
0 to 93%
Relative humidity
no condensation
Weight 88 g (0.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions 157 x 42 mm (DxH)


(installed in detector base) 6.2 x 1.7 inch (DxH)
311-510_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 21
Produktbla | Detekon

Standard detectors
Heat detectors, conventional

Heat detector WMX5151 Part no.: 918418


Conventional heat differential maximum detector. Designed
for application in areas where rapid development of heat
through flames is to be anticipated.

Product features Not included in delivery


• Modern and low-profile design Detector base BAX B110RLP  918421
• 2 LEDs provide 360° visibility in both
standby and alarm modes Connecting / mounting
• Easily accessible test marker for the application of a Connection cable standard detector 2-wire
functional magnet in order to alarm for service purposes (Connection via detector base)

Note
Applicable for operation with the fire alarm panel
Technical specifications
FMZ 5000 mod S CA (918493).
Detection method NTC temperature sensor
Technology conventional Approvals / marking
Operating voltage 8.5 V - 35 V DC
Quiescent current 0.08 mA
Alarm current 10 - 62 mA
Alarm indication 2 LEDs red, steady light
+57.2 °C
Static threshold value
+135 °F
Operating temperature 0°C to +38 °C
(according to UL Standard) (+32 °F to +100.4 °F)
Enclosure material PC/ABS Blend
10 to 93%
Relative humidity
no condensation
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 80 g (0.2 lbs)


Dimensions 157 x 42 mm (DxH)
(installed in detector base) 6.2 x 1.7 inch (DxH)
311-210_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 22
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional

Detector base BAX B110RLP Part no.: 918421


Detector base can be used for OMX2151 WMX5151 and
OWMX2151T. A resistor of 470 Ohm is integrated.

Not included in delivery


Mounting hardware
Back box
End of line-resistor (EOL)

Technical specifications
Material PC/ABS Blend
Relative humidity 10 to 93%
Colour white
0 °C to +49 °C
Operating temperature
(+32 °F to +120.2 °F)
Weight 130 g (0.3 lbs)
157 mm (D)
Dimensions
6.2 inch (D)

Parallel indicator RA100Z Part no.: 918422

Additional alarm indication for detectors with non-visible


alarm LED e.g. in false floors.

Not included in delivery


Mounting hardware
Back box / Single-Gang J-Box
The contents of this publication are subject to modifications without notice. All rights reserved.

Note
For use with conventional system the provided jumper must
Technical specifications
Operating voltage 3,1 - 32 V DC
Alarm indication 1 LED, red
Alarm current 10 mA
Approvals / marking
Enclosure material PC/ABS Blend
-10 °C to +60 °C
Ambient temperature
(+14 °F to +140 °F)
311-710_004 / AI01_2016en

Weight  62 g (0.1 lbs)


71 x 117 x 33 mm (BxHxT)
Dimensions
2.8 x 4.6 x 1.3 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 23
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional

Optical smoke detector OMX ECO1003 NEW Part no.: 921684


Conventional optical smoke detector for application
in areas where formation of smoke is to be anticipated
in case of fire. Smoke detector with special design
that uses algorithms for evaluation, thus achieving
high reliability in early fire detection.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base BAX ECO 470 Ohm 921689
software and hardware including the microcontroller End of line-resistor 1.8 K / 0.5 W 675235
• Evaluation of the signals with algorithms, which make
the detector less sensitive to sources of deception Connecting / mounting
• Automatic drift compensation Connection cable standard detector 2-wire
• Remote test unit for simplified commissioning Remote indication 2-wire
Recommended cable JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2 mm2 (AWG 14)

Technical specifications Approvals / marking


Detection method Infrared photo diode
Technology conventional G 201060 0832-CPD-0064
Operating voltage 8 V - 30 V DC
Recommended FMZ 5000 15 V DC
line voltage mod S 12 V DC
Quiescent current up to 75 µA
32 mA at 15 V
Alarm current
26 mA at 12 V
Alarm indication 1 LED red, steady light
-30 °C bis +70 °C
Operating temperature
(-22 °F to 158 °F)
IP rating (EN 60529) IP 40
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material ABS white


Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Weight 75 g (0.2 lb)
102 x 42 mm (D x H)
Dimensions
4.0 x 2.0 inch (D x H)
311-110_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 24
Product Sheet | Detecon

Standard detectors
Multisensor detectors, conventional

Multisensor detector OWMX ECO1002 NEW Part no.: 921685


Multisensor detector consisting of a combination of an
optical smoke detector and a heat detector. Designed for
the application in areas where periodically occurring sources
of deception are to be anticipated. The multisensor detector
is a thermally supported smoke detector. Its sensitivity is
considerably increased in case of flaming fires.

Product features Not included in delivery


• Constant function monitoring of the sensors, Detector base BAX ECO 470 Ohm 921689
software and hardware including the microcontroller End of line-resistor 1.8 K / 0.5 W 675235
• Evaluation of the signals with algorithms, which make
the detector less sensitive to sources of deception Connecting / mounting
• Automatic drift compensation Connection cable standard detector 2-wire
• Remote test unit for simplified commissioning Remote indication 2-wire
Recommended cable JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2 mm2 (AWG 14)

Technical specifications Approvals / marking


Detection method smoke Infrared photo diode
Detection method heat NTC temperature sensor G 201067 0832-CPD-0065
Technology conventional
Operating voltage 8 V - 30 V DC
Recommended FMZ 5000 15 V DC
line voltage mod S 12 V DC
Quiescent current up to 100 µA
32 mA at 15 V
Alarm current
26 mA at 12 V
Alarm indication 1 LED red
-30 °C to +70 °C
Operating temperature
(-22 °F to 158 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 20


Enclosure material ABS white
Relative humidity 5 to 95%
(IEC 721-3-3) no condensation
Weight 78 g (0.2 lb)
102 x 50 mm (D x H)
Dimensions
4.0 x 2.0 inch (D x H)
311-510_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 25
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

Heat detector WMX ECO1004T Class BS NEW Part no.: 921687


Conventional static heat detector. Designed for application in
areas where high rates of temperature rise may be sustained
for long periods, such as boiler rooms and kitchens.

Product features Not included in delivery


• Static measurement of increase in temperature Detector base BAX ECO 470 Ohm 921689
• Constant function monitoring of the sensors, End of line-resistor 1.8 K / 0.5 W 675235
software and hardware including the microcontroller
• Evaluation of the signals with algorithms, which make Connection / mounting
the detector less sensitive to sources of deception Connection cable standard detector 2-wire
• Remote test unit for simplified commissioning Remote indication 2-wire
Recommended cable JBY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2 mm2 (AWG 14)

Technical specifications
Approvals / marking
Detection method NTC temperature sensor
Technology conventional G 204042 0832-CPD-0068
Operating voltage 8 V - 30 V DC
Recommended FMZ 5000 15 V DC
line voltage mod S 12 V DC
Quiescent current up to 95 µA
32 mA at 15 V
Alarm current
26 mA at 12 V
Alarm indication 1 LED red
Temperature class, Class B,
rate of rise measurement acc. EN 54-5: 2000 / A1:2002
69 °C to 85 °C
Static response temperature
(156.2 °F to 185 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

-30 °C to +70 °C
Operating temperature
(-22 °F to +158 °F)
IP rating (EN 60529) IP 20
Enclousure material ABS white
Relative humidity max. 98%
(IEC 721-3-3) no condensation
Weight 70 g (0.2 lb)
102 x 50 mm (D x H)
Dimensions
4.0 x 2.0 inch (D x H)
311-210_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 26
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

Heat detector WMX ECO1005T Class A2S NEW Part no.: 921686
Conventional static heat detector. Designed for application in
areas where high rates of temperature rise may be sustained
for long periods, such as boiler rooms or kitchens.

Product features Not included in delivery


• Static measurement of increase in temperature Detector base BAX ECO 470 Ohm 921689
• Constant function monitoring of the sensors, End of line-resistor 1.8 K / 0.5 W 675235
software and hardware including the microcontroller
• Evaluation of the signals with algorithms, which make Connection / mounting
the detector less sensitive to sources of deception Connection cable standard detector 2-wire
• Remote test unit for simplified commissioning Remote indication 2-wire
Recommended cable JBY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2 mm2 (AWG 14)

Technical specifications Approvals / marking


Detection method NTC temperature sensor
Technology conventional G 201073 0832-CPD-0067
Operating voltage 8 V - 30 V DC
Recommended FMZ 5000 15 V DC
line voltage mod S 12 V DC
Quiescent current up to 95 µA
32 mA at 15 V
Alarm current
26 mA at 12 V
Alarm indication 1 LED red
Temperature class, Class A2,
rate of rise measurement acc. EN 54-5: 2000 / A1:2002
54 °C to 70 °C
Static response temperature
(129.2 °F to 158 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

-30 °C to +70 °C
Operating temperature
(-22 °F to +158 °F)
IP rating (EN 60529) IP 20
Enclousure material ABS white
Relative humidity max. 98%
(IEC 721-3-3) no condensation
Weight 70 g (0.2 lb)
102 x 50 mm (D x H)
Dimensions
4.0 x 2.0 inch (D x H)
311-210_003 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 27
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional

Heat detector WMX ECO1005 Class A1R NEW Part no.: 921688
Conventional combined rate-of-rise and static
heat detector. Designed for areas with rapid rise
of temperature caused by flames.

Produktmerkmale Not included in delivery


• Combined rate-of-rise and static measurement Detector base BAX ECO 470 Ohm 921689
• Constant function monitoring of the sensors, End of line-resistor 1.8 K / 0.5 W 675235
software and hardware including the microcontroller
• Evaluation of the signals with algorithms, which make Connection / mounting
the detector less sensitive to sources of deception Connection cable standard detector 2-wire
• Remote test unit for simplified commissioning Remote indication 2-wire
Recommended cable JBY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2 mm2 (AWG 14)

Technical specifications Approvals / marking


Detection method NTC temperature sensor
Technology conventional G 201016 0832-CPD-0066
Operating voltage 8 V - 30 V DC
Recommended FMZ 5000 15 V DC
line voltage mod S 12 V DC
Quiescent current up to 95 µA
32 mA at 15 V
Alarm current
26 mA at 12 V
Alarm indication 1 LED red
Temperature class, Class A1,
rate of rise measurement acc. EN 54-5: 2000 / A1:2002
54 °C to 65 °C
Static response temperature
(129.2 °F to 149 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

-30 °C to +70 °C
Operating temperature
(-22 °F to +158 °F)
IP rating (EN 60529) IP 20
Enclousure material ABS white
Relative humidity max. 98%
(IEC 721-3-3) no condensation
Weight 70 g (0.2 lb)
102 x 50 mm (D x H)
Dimensions
4.0 x 2.0 inch (D x H)
311-210_004 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 28
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional

Detector base BAX ECO 470 Ohm NEW Part no.: 921689
Standard detector base with integrated alarm resistor

Not included in delivery


Mounting hardware

Technical specifications Approvals / marking


Enclousure material ABS
0 to 95 %
Relative humidity
no condensation
Colour white
-30 °C to +70 °C
Operating temperature
(-22 °F to 158 °F)
Weight 42 g (0.09 lb)
102 mm (D)
Dimensions
4.0 inch (D)

Remote test unit ECO1000 RTU NEW Part no.: 921690


For the ECO1000 product range an alarm can be triggered
for test and commissioning purposes without the need of
step ladders or long poles. For this, the modulated laser
beam of the remote test unit is directed at the detectors LED,
whereby the detector latches into alarm.
The contents of this publication are subject to modifications without notice. All rights reserved.

Product feature Approvals / marking


• Simple and fast triggering of test alarms for
ECO1000 series detectors

Technical specifications
Alarm trigger latching, no functional sensor test
Battery included in delivery
Batteries required 1 x 6 V, type 11A
311-710_003 / AI00_2015en

Weight 23 g (0.05 lb)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 29
Product Sheet | Detecon

Standard detectors
Optical smoke detectors, conventional, Ex

Optical smoke detector OMX 1001C Ex Part no.: 800833


Conventional intrinsically safe optical smoke detector for Ex
zone 1. Designed for use in areas with smoke in case of fire.
Robust smoke detector with drift compensation for use in
industrial environments. Designed for use in hazard areas
connected to a safety barrier Ex Standard 9 V.
The barrier has to be placed in non hazard areas.

Product features Included in delivery


• Constant funktion monitoring of sensors, 1 Optical smoke detector
software and hardware including the microcontroller 1 Operating manual, german 901123
1 Operating manual, english 901772
• Normal operation indication by green flashing light
• Automatic drift compensation
Not included in delivery
• Robust smoke detector Detector base  903502 or 903503
see detectors accessories, conventional
End of line-resistor 1.8 K / 0.5 W 675235
Dust cover  894760
Technical specifications
Safety barrier IS conventional 9 V 904991
Detection method Infrared photo diode
Measurement chamber Connection / mounting
approx. 0.16 dB/m (39.4 inch)
sensitivity
Connection cable standard detector 2-wire
Number of detectors per line max. 24 Remote Indication  2-wire
Technology conventional Recommended cable  JEY (St) Y 2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 7.6 V - 13.2 V DC
Quiescent current approx. 0.35 mA
Note
Alarm current approx. 18 mA
The detector housing has a high surface resistance.
Alarm indication 1 LED red, permanent light Avoid electrostatic charging.
Normal operation indication 1 LED green, flashing light
Electrostatic shielding recommended Approvals / marking
-20 °C to +60 °C Ex conformity in acc. with 94/9/EG
Operating temperature, T4
x II 2G Ex ia IIC T6...T4 Gb
The contents of this publication are subject to modifications without notice. All rights reserved.

(-4 °F to +140 °F)


-20 °C to +40 °C EC type approval certificate: DMT 00 ATEX E 043
Operating temperature, T6 Ex conformity Russia in acc. with TP TC 012/2011:
(-4 °F to +104 °F)
1Ex ia IIC T6/T4 Gb
-40 °C to +85 °C
Storage temperature
(-40 °F to +185 °F)
IP 43, with membrane plug and
IP rating (EN 60529) G 200005 0786-CPD-20131
sealing of the mounting holes
Enclosure material white polycarbonate
Relative humidity max. 95% at 35 °C (+95 °F)
(IEC 721-3-3) no condensation
Specification according to EN 54-7
311-130_002 / AI00_2015en

Weight 240 g (0,5 lbs)


113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 30
Product Sheet | Detecon

Standard detectors
Ionisation smoke detectors, conventional, Ex

Ionisation smoke detector IMX 1001E Ex Part no.: 782410


Conventional ionisation smoke detector for Ex zone 1.
Designed for use in areas with smoke in case of fire.
Robust smoke detector with a dual ionisation chamber for
use in industrial environments. Designed for use in hazard
areas connected to a safety barrier Ex Standard 9 V.
The barrier has to be placed in non hazard areas.

Product features Not included in delivery


• Drift compensation by dual ionization Detector base  903502 or 903503
see detectors accessories, conventional
• Robust smoke detector
End of line-resister 1.8 K / 0.5 W 675235
Dust cover  894760
Safety barrier IS conventional 9 V 904991
Technical specifications
Detection method Double ionization chambers Connection / mounting
Connection cable standard detector 2-wire
Technology conventional
Remote Indication  2-wire
Operating voltage 7.6 V - 13.2 V DC Recommended cable  JEY (St) Y 2x2x0.8 mm2, blue
Quiescent current approx. 0.08 mA Conductor cross-section max. 2.5 mm2
Alarm current approx. 20 mA
Alarm indication 1 LED red Note
The detector housing has a high surface resistance. Avoid
Sensitivity y = 0,8
electrostatic charging. The detector contains radioactive
Air flow max. 5 m/s materials. The operating instructions and current laws and
Radioactivity Am241 2,8 kBq regulations on radiation protection must be observed.
Electrostatic shielding recommended
-20 °C to +75 °C Approvals / marking
Operating temperature T4
(-4 °F to +167 °F) Ex conformity in acc. with 94/9/EG
-20 °C to +40 °C x II 2G Ex ib IIC T6...T4 Gb
Operating temperature T6 EC type approval certificate: BVS 03 ATEX 2110
(-4 °F to +104 °F)
-30 °C to +80 °C
Storage temperature
(-22 °F to +176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

G 28119 0786-CPD-20211
IP 43, with membrane plug and
IP rating (EN 60529)
sealing of the mounting holes
Enclosure material white polycarbonate
Relative humidity max. 98% bei 35°C (+95 °F)
(IEC 721-3-3) Avoid condensation
Specification according to EN 54-7
Weight 230 g (0.5 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
311-180_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 31
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional, Ex

Heat detector WMX 1000D60 Ex Part no.: 782422


Conventional combined rate of rise and static heat detector
for Ex zone 1. Designed for areas with rapid rase of
temperature by flames. Heat detector with 2 temperature
sensors for use in industrial environments. Designed for use
in hazard areas connected to a safety barrier Ex Standard 9
V. The barrier has to be placed in non hazard areas.

Product features Not included in delivery


• Adaptation to ambient temperature Detector base  903502 or 903503
by 2 temperature sensors see detectors accessories, conventional
End of line-resistor 1.8 K / 0.5 W 675235
• Combined rate-of-rise and static measurement
Dust cover  894760
• Robust heat detector Safety barrier IS conventional 9 V 904991

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Remote Indication  2-wire
Detection method NTC-temperature sensor
Recommended cable  JEY (St) Y 2x2x0.8 mm, blue
Technology conventional Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 7.6 V - 13.2 V DC
Quiescent current approx. 0.07 mA Note
Alarm current approx. 15 mA The detector housing has a high surface resistance.
Avoid electrostatic charging.
Alarm indication 1 LED red
Temperature class, Class A1,
rate of rise measurement acc. to EN 54-5: 2000 / A1:2002 Approvals / marking
+54 °C to +62 °C
Ex conformity in acc. with 94/9/EG
Static threshold value
(+129.2 °F to +143.6 °F) x II 2G Ex ib IIC T6...T4 Gb
EC type approval certificate: BVS 03 ATEX E 104
Elektrostatic shielding recommended
Ex conformity Russia in acc. with TP TC 012/2011:
-20 °C to +50 °C 1Ex ia IIC T5/T4 Gb
Operating temperature
(-4 °F to +122 °F)
IP 23, with membrane plug and
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529)


sealing of the mounting holes G 27918 0786-CPD-20208
Enclosure material white polycarbonate
Relative humidity max. 95%
(IEC 721-3-3) no condensation
Specification according to EN 54-5
Weight 140 g (0.3 lbs)
113 x 68 mm (DxH)
Dimensions
4.5 x 2.7 inch (DxH)
311-230_002 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 32
Product Sheet | Detecon

Standard detectors
Heat detectors, conventional, Ex

Heat detector WMX1000D90 Ex Part no.: 782434

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EG
Temperature class, Class C,
rate of rise measurement acc. to EN 54-5: 2000 / A1:2002
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certificate: BVS 03 ATEX E 104
+84 °C to +100 °C Ex conformity Russia in acc. with TP TC 012/2011:
Static threshold value
(+183.2 °F to +212 °F) 1Ex ia IIC T5/T4 Gb
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Weight 140 g (0.3 lbs) G 27918 0786-CPD-20209

Otherwise like part no.: 782422

Heat detector WMX1000D105 Ex Part no.: 907368

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EG
Temperature class, Class D,
rate of rise measurement acc. to EN 54-5: 2000 / A1:2002
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certificate: BVS 03 ATEX E 104
+100 °C to +115 °C Ex conformity Russia in acc. with TP TC 012/2011:
Static threshold value
(+212 °F to +239 °F) 1Ex ia IIC T5/T4 Gb
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Weight 140 g (0.3 lbs)

Otherwise like part no.: 782422


The contents of this publication are subject to modifications without notice. All rights reserved.

Heat detector WMX1000D80M Ex Part no.: 903508

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EG
+77 °C to +83 °C
Static threshold value
(+170.6 °F to +181.4 °F)
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certificate: BVS 03 ATEX E 104
-20 °C to +70 °C Ex conformity Russia in acc. with TP TC 012/2011:
Operating temperature
(-4 °F to +158 °F)
1Ex ia IIC T5/T4 Gb
Weight 130 g (0.3 lbs)

Otherwise like part no.: 782422


311-230_002 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 33
Product Sheet | Detecon

Standard detectors
Detector accessories, conventional,Ex

Junction box Ex Part no.: 900288


Junction box for hazard areas, can be used in zone 1

Included in delivery
1 Junction box Ex with 4 cable glands M25 for cable
Ø 10 - 17 mm and 2 closures M25.
6 Clamps, clamping range to 2.5 mm2 (AWG13)

Not included in delivery


Mounting hardware

Technical specifications Approvals / marking


Ex conformity in acc. with 94/9/EG
Material Polyamid
x II 2G Ex dem ia II, IIC T6
IP rating (EN 60529) IP 66 EC type approval certificate: PTB 00 ATEX 3108
Colour black
-20 °C to +40 °C
Operating temperature
(-4 °F to +104 °F)
Weight 300 g ( 0.66 lbs)
122 x 180 x 61 mm (WxHxD)
Dimensions
4.8 x 7.1 x 2.4 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-730_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 34
Product Sheet | Detecon

Standard detectors
Detector accessories

Deckhead mounting box ACX 196 Part no.: 905403


Back box for detector base for surface mounting,
with lateral cable entry for M20 cable glands.
Stable ABS enclosure in robust design.

Not included in delivery


Cable glands M20x1.5 902901
Blind plug  902922

Technical specifications
Material ABS
Weight 404 g (0.9 lbs)
146 x 38 mm (dia. x H)
Dimensions
5.8 x 1.5 inch (dia. x H)

Cable floor-detector holder BHX 1000, Part no.: 908691


d=20 mm to 25 mm (0.79 inch to 0.98 inch) Cable floor-detector holder for underfloor installation.
The standard fastener is designed for round pipes with
a diameter of 20 - 25 mm (0.78 to 0.98 inch). Other fasteners
on request. The plate area is designed for smoke and heat
detector bases of many detector suppliers.

Included in delivery
1 Packaging unit (10 x)
Cable floor-detector holder BHX 1000
2 Mounting screws 4.2 x 13 (DIN 7981-St)

Technical specifications
The contents of this publication are subject to modifications without notice. All rights reserved.

Material Sheet steel, powder-coated


Colour RAL 7035
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
Weight 290 g (0.6 lbs)
112 x 330 mm (dia. x H)
Dimensions
4.4 x 13 inch (dia. x H)
311-740_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 35
Product Sheet | Detecon

Standard detectors
Detector accessories

Remote indicator LMX5000 Part no.: 908499


Additional remote indication for detectors with
non visible alarm LED e.g. in false floors.
Insertable for Loop AP and conventional technology.
Do not use the remote indicator in hazard areas.

Not included in delivery


Mounting materials

Approvals / marking

Technical specifications
Nominal voltage Loop AP 24 V DC
conventional 9 V DC
Electrostatic shielding not required
Enclosure material ABS, RAL 9010 - white
Relative humidity 98 %, avoid condensation
-10 °C to +60 °C
Ambient temperature
(-14 °F to +140 °F)
IP rating IP 30
Weight 66 g (0.2 lbs)
84 x 84 x 35 mm (WxHxD)
Dimensions
3.3 x 3.3 x 1.4 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-740_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 36
Product Sheet | Detecon

Standard detectors
Detector accessories

Junction box ACX 204 Part no.: 901247


Junction box for flush mounted installation by the customer
in concrete ceiling slabs, with prefabricated attachment
points for the detector base. Break-off tabs for cable entries,
M16 and M20 wiring conduit.

Note
Not applicable in combination with:
- detector base metric, 3-pin 903502
- detector base metric, 5-pin 903503
- and the associated detectors series

Approvals / marking

Technical specifications
Material PC
100 x 8 mm (dia. x H)
Dimensions
3.9 x 0.3 inch (dia. x H)

Backplate ACX 233 Part no.: 901245


Protection plate against dust and water to add to the detector
base during assembly. When using addressable detectors
the number identification must be removed and inserted at
the points provided in the backplate.

Note
Not applicable in combination with:
- detector base metric, 3-pin 903502
- detector base metric, 5-pin 903503
- and the associated detectors series

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.
311-740_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 37
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input module IUX 760 M-I Part no.: 908531


Miniature interface for use in devices with little space.
The mini switch monitor monitors the state of one or more
dry normally open contacts and reports the status to a fire
alarm panel. Applicable for operation in fire alarm panels
with Loop AP protocol. Optional equipped with interrupt
for rapid alarm signals like a manual call point.
The states “quiescent”, “pre-alarm”, “alarm” and “fault”
can be recognised. Addressing via DIP switches; the
address can also be modified after installation.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1,5 mm2 (AWG 15)
Technical specifications Electrostatic shielding  not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption Voltage at contact input  9 - 11 V DC
at 24 V DC: Cable resistance max.  50 Ohm
0.2 mA
Min. (quiescent) End-of-line resistor EOL (R3) 20 kOhm
3.6 mA
Max. (alarm input)
Pre-alarm resistor (R2) 10 kOhm
Alarm indication red LED Alarm resistor (R1) 1 kOhm
Bus activity indication green LED
Short-circuit indication Connection diagram
on the loop or fault of the yellow LED
monitores input
Integrated isolator yes
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Weight 30 g (0.1 lbs)
39 x 39 x 20 mm (WxHxD)
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

1.5 x 1.5 x 0.8 inch (WxHxD)

Approvals / marking

G 210034 0832-CPD-1072
311-810_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 38
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input module IUX 822 R Part no.: 905395


Analogue addressable input module for monitoring a dry
contact including line monitoring. DIN rail (R) installation
version. The states “quiescent”, “pre-alarm”, “alarm” and
“fault” can be recognised. Applicable for operation in fire
alarm panels with Loop AP protocol. Addressing via DIP
switches; the address can also be modified after installation.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section  max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding  not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input  9 - 11 V DC
Quiescent 0.73 mA Cable resistance max.  50 Ohm
Alarm 3.4 mA End-of-line resistor EOL 20 kOhm
Short-circuit 5.6 mA
Pre-alarm resistor  10 kOhm
Indication of activated input red LED Alarm resistor 1 kOhm
Fault indication yellow LED
Integrated isolator no Connection diagram
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals

0832-CPD-0857
311-810_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 39
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input/output module IOX 821 R Part no.: 905558


Analogue addressable input module for monitoring a dry
contact including line monitoring. DIN rail installation version.
The states “quiescent”, “pre-alarm”, “alarm” and “fault” can
be recognised. The alarm status can be set with 30 seconds
delay via a DIP switch. An optocoupler output is available and
can be used with additional electronics to reset detectors.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation.

Inputs : 1 Connection / mounting


Outputs : 1 (optocoupler) Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section  max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input  9 - 11 V DC
Quiescent 0.73 mA Cable resistance max.  50 Ohm
Alarm 3.5 mA End-of-line resistor EOL 20 kOhm
Short circuit 5.6 mA
Pre-alarm resistor 10 kOhm
Indication of activated input red LED Alarm resistor 1 kOhm
Fault indication yellow LED
Optocoupler output:
Integrated isolator no
Voltage range  5 - 30 V DC
-20 °C to +70 °C Guaranteed current  1 mA
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 20
Connection diagram
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

0832-CPD-0856
311-810_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 40
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Input/output module IOX 803 R Part no.: 905803


Analogue addressable input/output module for monitoring
a dry contact including line monitoring and additional
optocoupler input, and for controlling an output via a relay.
DIN rail installation version. The states “quiescent”, “alarm”
and “fault” can be recognised. Applicable for operation in
fire alarm panels with Loop AP protocol. Addressing via DIP
switches; the address can also be modified after installation.

Inputs : 2 (of which 1 optocoupler) Connection / mounting


Outputs : 1 Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section  max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding  not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption Voltage at contact input  9 - 11 V DC
Quiescent 0.73 mA Cable resistance max.  50 Ohm
Alarm 3.5 mA End-of-line resistor EOL 20 kOhm
Short circuit 6.0 mA
Alarm resistor 4.7 kOhm
Indication of activated input red LED
Active output indication red LED Optocoupler input:
Voltage range  max. 35 V DC
Fault indication yellow LED
Impedance  10 kOhm
Integrated isolator no
-20 °C to +70 °C Relay output:
Operating temperature
(-4 °F to +158 °F) Voltage max. 30 V DC
IP rating (EN 60529) IP 20
Current max. 1 A DC

Technology / protocol Loop AP / XP95


Relative humidity 0 to 95%
Note:
(IEC 721-3-3) no condensation In FMZ 5000 technique, input signals of this module type
can only be used as binary signals. These signals can not be
Specification according to CEA GEI 1-052 (6/97)
assigned to any group or detector numbers.
Weight 95 g (0.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

110 x 107 x 20 mm (WxHxD) Connection diagram


Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)

Approvals / marking

0832-CPD-0854
311-810_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 41
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Output module OUX 804 R Part no.: 905402


Analogue addressable output module providing
a dry contact. DIN rail (R) installation versions.
Applicable for operation in fire alarm panels with
Loop AP protocol. Addressing via DIP switches;
the address can also be modified after installation.

Inputs : 0 Connection / mounting


Outputs : 1 Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section  max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding  not required
Operating voltage 17 V - 28 V DC
Relay output:
Current consumption: Voltage max. 30 V DC
Quiescent 0.72 mA Current max. 1 A DC
Alarm 3.3 mA
Indication of activated input red LED
Connection diagram
Integrated isolator no
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 20
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

0832-CPD-0855
311-810_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 42
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

Sounder control module SCX 182 R Part no.: 905396


Analogue addressable sounder control module for controlling
sounders in continuous or pulse-controlled operation with
additional contact input for monitoring the external power
supply of the sounders. DIN rail (R) installation versions.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation.

Inputs : 1 (contact input) Connection / mounting


Outputs : 1 Connection cable  2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
External power supply 9 - 50 V DC
Current consumption: Contact input  NC for failure of the external
Quiescent 1.9 mA power supply
Output active 1.7 mA
Short circuit 4.5 mA
Relay output:
Indication of activated output red LED Voltage max. 35 V DC
Fault indication yellow LED Current max. 4 A DC
Integrated isolator no
Note
-20 °C to +70 °C
Operating temperature The output of the sounder control module operates with
(-4 °F to +158 °F)
polarity switching. The device is conected with reversed
IP rating (EN 60529) IP 20 voltage polarity. Triggering the device output activates the
Technology / protocol Loop AP / XP95 polartity switchover which activates the connected sounders.
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Connection diagram
Specification according to CEA GEI 1-052 (6/97)
Weight 95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
Dimensions
4.3 x 4.2 x 0.8 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

G 201095 0832-CPD-0852
311-810_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 43
Product Sheet | Detecon

Standard detectors
Modules, addressable, DIN rail mounting

FMZ5000 loop coupler module Part no.: 902954


Functional module for use in all design variants of the fire
alarm system FMZ 5000. The loop coupler module is
a loop node on a loop of the loop module. It includes
4 conventional detector zones with their own addresses,
which are detected and dealt by the fire alarm panel like
four detectors of the detector loop. The status of the
detector zones and the detectors are reported to the fire
alarm panel via the configured address.
Detectors can be connected in two-detector dependancies
and groups can be connected in group dependancies.
For use in hazard areas, detectors in intrinsically safe design
can be connected via Zener barriers. The detector lines have
a common base address, which is set in increments of 4 for
all detector lines. The module has a default configuration that
Product features can be modified using the configuration software MxLoopCon,
• For the interface connection of conventional detectors Part no. 904001.
to a loop of the loop module
• The module has four conventional detector zones Application
• Alarm and pre-alarm of every zone are transmitted. Mainly for the interface connection of industrial detectors
The zones can be deactivated individually via the loop in conventional detector technology to a Loop AP.
• For installation into the fire alarm panel
Included in delivery
Module completely assembled and ready for
installation in the fire alarm panel.
Technical specifications
Operating voltage 19 V - 29 V DC Application in potentially explosive atmospheres
approx. 20 mA Only permitted for use with barrier:
Quiescent current
without line terminations
Safety barrier loop AP 24 V  901324
Current consumption per line max. 100 mA DC
Line voltage, min 9 V - 19 V DC
Note
Technology / protocol Loop AP / XP95
The module may not be plugged in together with other
Alarm / terminating resistor 470 Ohm / 1.8 kOhm
functional modules of the FMZ 5000 series. It must be
Number of lines per module 4 individually placed in the fire alarm panel. To supply the
Number of detectors per line 32 conventional lines, the loop coupler
Max. terminal cross-section 2.5 mm2 (AWG 13) module requires an external 24 V DC power supply.
Integrated isolator no

Ambient temperature
-5 °C to +40 °C Connection diagram
(+23 °F to +104 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 95 %


(IEC 721-3-3) no condensation
IP rating (EN 60529) IP 20
Enclosure Polyamide PA6.6, green
Detectors per loop max. 30
Mounting rail 35 DIN 46277,
Mounting
top hat profile
Weight 200 g (0.4 lbs)
35 x 99 x 114.5 mm (WxHxD)
Dimensions
1.4 x 3.9 x 4.5 inch (WxHxD)
311-810_007 / AI01_2016en

Approvals / marking

see panels

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 44
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input module IUX 843 W-I Part no.: 905399


Analogue addressable input module for monitoring a
dry contact including line monitoring. In the version for
wall-mounted installation (W). The states “quiescent”,
“pre-alarm”, “alarm” and “fault” can be recognised.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can
also be modified after installation.
The electronics features an integrated isolator; fault condition,
short circuit or open line is indicated.

Inputs : 1 Connection / mounting


Outputs : 0 Connection cable 2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input 9 - 11 V DC
Quiescent 1.25 mA Cable resistance max. 50 Ohm
Alarm 3.5 mA End-of-line resistor EOL 20 kOhm
Short circuit 3.6 mA
Pre-alarm resistor 10 kOhm
Indication input active red LED Alarm resistor 1 kOhm
Fault indication 2 yellow LEDs
Integrated isolator yes Connection diagram
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

G 201033 0832-CPD-0867
311-810_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 45
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 841 W-I Part no.: 905398


Analogue addressable input module for monitoring a dry
contact including line monitoring. Wall-mounted installation
version. The states “quiescent”, “pre-alarm”, “alarm” and
“fault” can be recognised. The pre-alarm status can be
set with 30 seconds delay via a DIP switch.
An optocoupler output is available and can be used with
additional electronics to reset detectors.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modified after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.

Inputs : 1 Connection / mounting


Outputs : 1 (optocoupler) Connection cable 2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input 9 - 11 V DC
Quiescent 1.25 mA Cable resistance max. 50 Ohm
Alarm 3.4 mA End-of-line resistor EOL 20 kOhm
Short circuit 4.2 mA
Pre-alarm resistor 10 kOhm
Indication input active red LED Alarm resistor 1 kOhm
Fault indication 2 yellow LEDs
Optocoupler output:
Integrated isolator yes
Voltage range 5 - 30 V DC
-20 °C to +70 °C Guaranteed current 1 mA
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 54
Connection diagram
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

G 201033 0832-CPD-0866
311-810_009 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 46
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 847 W-I Part no.: 905400


Analogue addressable input/output module for monitoring
a dry contact including line monitoring and additional
optocoupler input, and for controlling an output via two
separate relays. In the wall-mounted installation version.
The states “quiescent”, “alarm” and “fault” can be recognised.
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can
also be modified after installation. The electronics features
an integrated isolator; a fault, short circuit or open line is
indicated.

Inputs : 2 (of which 1 optocoupler) Connection / mounting


Outputs : 1 Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input 9 - 11 V DC
Quiescent 1.25 mA Cable resistance max. 50 Ohm
Alarm 3.5 mA End-of-line resistor EOL 20 kOhm
Output active additional 2 mA
Alarm resistor 1 kOhm
Indication input active red LED
Active output indication red LED Optocoupler input:
Voltage range max. 35 V DC
Fault indication 2 yellow LEDs
Impedance 10 kOhm
Integrated isolator yes
-20 °C to +70 °C Relay outputs:
Operating temperature
(-4 °F to +158 °F) Amount 2 changeover contacts electrical separated
IP rating (EN 60529) IP 54
Voltage max. 30 V DC
Current max. 1 A DC
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Note
In FMZ 5000 technique, input signals of this module type
Specification according to CEA GEI 1-052 (6/97)
can only be used as binary signals. These signals can not
Weight 240 g (0.5 lbs) be assigned to any group or detector numbers.
The contents of this publication are subject to modifications without notice. All rights reserved.

150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
Connection diagram

Approvals / marking

G 201032 0832-CPD-0869
311-810_010 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Kapitel 5 - 47
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 875 W-I AC Part no.: 905561


Analogue addressable input/output module for monitoring
a dry contact including line monitoring and for controlling
an output via a relay (230 V AC switchable). In the version
for wall-mounted installation (W). The inputs can recognise
the states “quiescent”, “alarm” and “fault”. Applicable for
operation in fire alarm panels with Loop AP protocol.
Addressing via DIP switches; the address can also be
modified after installation.

Inputs : 1 Connection / mounting


Outputs : 1 Connection cable 2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC Contact input:
Current consumption: Voltage at contact input 9 - 11 V DC
Quiescent 1.25 mA Cable resistance max. 50 Ohm
Alarm 2.5 mA End-of-line resistor EOL 20 kOhm
Output active additional 2 mA Alarm resistor 470 Ohm
Indication input active red LED
Active output indication red LED Relay output:
Voltage max. 48 V DC / 250 V AC
Fault indication yellow LED Current max. 2 A DC / 5 A AC
Integrated isolator no
-20 °C to +70 °C Note
Operating temperature
(-4 °F to +158 °F)
In FMZ 5000 technique, input signals of this module type
IP rating (EN 60529) IP 54 can only be used as binary signals. These signals can not
Technology / protocol Loop AP / XP95 be assigned to any group or dector numbers.
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Connection diagram
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

0832-CPD-0860
311-810_011 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 48
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Input/output module IOX 588 W-I Part no.: 905557


Analogue addressable input/output module for monitoring dry
contacts including line monitoring and for controlling outputs
via relays. Version for wall-mounted installation (W).
The inputs can recognise the states “quiescent”, “alarm”
and “fault”. Applicable for operation in fire alarm panels
with Loop AP protocol. Addressing via DIP switches;
the address can also be modified after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.

Inputs : 3 Connection / mounting


Outputs : 3 Connection cable 2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Contact input:
Current consumption: Voltage at contact input 9 - 11 V DC
Quiescent 3.0 mA Cable resistance max. 50 Ohm
Maximal 7.5 mA End-of-line resistor EOL 20 kOhm
Indication input active 3 red LEDs Alarm resistor 4.7 kOhm
Active output indication 3 red LEDs
Relay outputs:
Fault indication input 3 yellow LEDs
Voltage max. 30 V DC
Fault indication isolator yellow LED Current max. 1 A DC
Integrated isolator yes

Operating temperature
-20 °C to +70 °C Note
(-4 °F to +158 °F) In FMZ 5000 technique, input signals of this module type
IP rating (EN 60529) IP 54 can only be used as binary signals. These signals can not
be assigned to any group or dector numbers.
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation Connection diagram
Specification according to CEA GEI 1-052 (6/97)
Weight 621 g (1.4 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

250 x 175 x 75 mm (WxHxD)


Dimensions
9.8 x 6.9 x 3 inch (WxHxD)

Approvals / marking

G 202052 0832-CPD-0864
311-810_012 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 49
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Output module OUX 849 W-I Part no.: 905401


Analogue addressable output module with one output via two
separate relays. Version for wall-mounted installation (W).
Applicable for operation in fire alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can
also be modified after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.

Inputs : 0 Connection / mounting


Outputs : 1 Connection cable  2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Relay outputs:
Current consumption: Amount 2 changeover contacts electrical separated
Quiescent 0.4 mA Voltage max. 30 V DC
Output active 1.8 mA Current max. 1 A DC
Active output indication red LED
Fault indication yellow LED Connection diagram
Integrated isolator yes
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

G 201032 0832-CPD-0870
311-810_013 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 50
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Sounder control module SCX 852 W-I Part no.: 905560


Analogue addressable sounder control module for
controlling sounders in continuous or pulse-controlled
operation with additional contact input for monitoring
the external power supply of the sounders. Version for
wall-mounted installation (W). Applicable for operation
in fire alarm panels with Loop AP protocol. Addressing
via DIP switches; the address can also be modified after
installation. The electronics features an integrated isolator;
a fault, short circuit or open line is indicated.

Inputs : 1 (contact input) Connection / mounting


Outputs : 1 Connection cable 2-wire
Recommended cable, standard 747180
JY(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
External power supply 9 - 50 V DC
Current consumption: Contact input NC/NO contact
Quiescent 1.9 mA for fault of the external power supply
Output active 1.7 mA
Short circuit 3.6 mA
Relay output:
Active output indication red LED Voltage max. 30 V DC
Fault indication 2 yellow LEDs Current max. 1 A DC
Integrated isolator yes
-20 °C to +70 °C Note
Operating temperature
(-4 °F to +158 °F) The output of the sounder control module operates with
IP rating (EN 60529) IP 54
polarity switching. The device is conected with reversed
voltage polarity. Triggering the device output activates the
Technology / protocol Loop AP / XP95 polartity switchover which activates the connected sounders.
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Connection diagram
Specification according to CEA GEI 1-052 (6/97)
Weight 240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Approvals / marking

G 201095 0832-CPD-0871
311-810_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 51
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

Conventional zone module ZMX 845 W-I Part no.: 905804


Analogue addressable module for monitoring a conventional
zone. Automatic detectors and manual call points using
conventional technology can be connected. Version for
wall-mounted installation (W). The states “quiescent”, “alarm”
and “fault” can be recognised. Applicable for operation in
fire alarm panels with Loop AP protocol. Addressing via DIP
switches; the address can also be modified after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.

Inputs : 1 (conventional zone) Connection / mounting


Outputs : 0 Connection cable  2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (AWG 15)
Technical specifications Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Limit value zone:
19 V ± 1 V DC or Voltage  19 V ±1 V DC or
Voltage output
at operating voltage < 22 V at Operating voltage < 22 V
conventional zone
= operating voltage minus 1,5 V = Operating voltage minus 1,5 V
Current consumption: Terminating resistor  5.1 kOhm
Quiescent 4.0 mA + detector
Alarm 19.0 mA + detector
Connection diagram
Zone alarm indication red LED
Fault indication yellow LED
Integrated isolator yes
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 54
Technology / protocol Loop AP / XP95
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Weight 230 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions
5.9 x 3.5 x 1.9 inch (WxHxD)

Approvals / marking

G 201094 0832-CPD-0868
311-810_015 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 52
Product Sheet | Detecon

Standard detectors
Modules, addressable, wall mounting

FMZ5000 loop coupler Part no.: 908131


The loop coupler consists of a loop coupler module,
Part no.: 902954, which is mounted in a surface mount
wall enclosure with IP 65 protection rating. According to
DIN VDE 0833-2, Section 6.2.5, no more than the following
may be connected to an FMZ 5000 loop coupler:
e.g. max. 1 detection range with max. 1600 m² (1913 square
yard) or 32 automatic detectors of a detection range or
10 manual call points of a detection range.
The only loop coupler module that may only be fitted outside
the fire alarm panel is the FMZ 5000 loop coupler.

Product features Application


• For the connection of conventional detectors For the interface connection of industrial detectors in
to a loop of the loop module conventional technology to a Loop AP.
The FMZ 5000 loop coupler can be installed directly in the
• The device has a loop coupler module monitoring area. The voltage supply can be provided via
• Can be expanded by adding another the fire alarm panel or a separate power supply unit (in
loop coupler module accordance with EN 54-4 A2). If more than 32 detectors are
connected, the power supply line must have a redundant
design. To supply the conventional lines, the loop coupler
module requires an external 24 V DC power supply.
Technical specifications
Operating voltage 19 V - 28 V DC Included in delivery
approx. 20 mA Device completely assembled and ready for installation
Quiescent current consumption
without line terminations in the area.
Current consumption, approx. 40 mA Supplementary sheet.
2 modules without line terminations
Line voltage, min 9 - 19 V DC
Not included in delivery
Alarm / 470 Ohm /
terminating resistor 1.8 kiloOhm Mounting hardware, further cable glands
Number of detectors per line 32
Technology / protocol Loop AP / XP95 Note
Number of loop coupler To install the device or an additional module the
1, expandable to 2 loop coupler supplementary sheet, Part no.:908048,
modules
IP rating (EN 60529) IP 65 needs to be observed.
Conductor cross-section 2.5 mm (AWG 13)
2

Connection diagram
The contents of this publication are subject to modifications without notice. All rights reserved.

Integrated isolator no
-5 °C to +40 °C
Ambient temperature
(+23 °F to +104 °F)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to CEA GEI 1-052 (6/97)
Enclosure transparent plastic
Installation position vertical
Weight 350 g (0.8 lbs)
187.5 x 250 x 175 mm (WxHxD)
Dimensions
7.4 x 9.8 x 6.9 inch (WxHxD)
311-810_016 / AI00_2015en

Approvals / marking

G 209028 0786-CPD-20684

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 53
Product Sheet | Detecon

Standard detectors
Modules, addressable

SUX5000 AP monitoring module Part no.: 906973


The SUX5000 AP is a monitoring module for the installation
of fault and alarm signal transmitters in two-wire loop systems
with individual identification.
It allows the individual addressing of dry contactors such as
pressure switches, limit switches, extinguishing agent level
sensors or temperature sensors, with plain text information to
the FMZ 5000 fire alarm system or Loop AP-compatible fire
alarm systems.

Product features Included in delivery


• Integration into the switching device to be monitored 1 Packaging unit (5x)
• Monitored signal path SUX5000 AP monitoring module
• Loop integration, addressing via DIP switch on module
• Special applications: Not included in delivery
connection to external contact, connection of LEDs, Fault- or alarm device
hardware fault signal suppression
Note
The SUX5000 AP can be used in combination with the
following devices:
Technical specifications
Card adapter SUX50 universal 902698
Operating voltage 17 V - 28 V DC Reed contact limit switch  886343
Rated voltage 24 V DC Float switch monitoring  879475
Float switch monitoring sprinkler panel 842358
Quiescent current 230 μA
Pressure switch PMÜ-3  792183
Operating current 300 μA Pressure switch PMÜ-10  810564
Integrated isolator no Pressure switch PMA-3  116512
-40 °C to +80 °C
Operating temperature
(-40 °F to +176 °F) Approvals / marking
Technology / protocol Loop AP / XP95
Relative humidity 0 to 93% G 208059 0786-CPD-20416
(IEC 721-3-3) no condensation
Weight 4 g (0.01 lbs)
38.5 x 28.5 x 8 mm (WxHxD)
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

1.5 x 1.1 x 0.3 inch (WxHxD)


311-810_017 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 54
Product Sheet | Detecon

Standard detectors
Modules, conventional

Card LÖ leakage detector Part no.: 800707


Monitoring card for connection of LKM2001 flow detector to
FMZ 4100 and FMZ 5000 control units.

Connection / mounting
Connection cable  2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (AWG 13), solid conductor
max. 1.5 mm2 (AWG 15), strand with wire end sleeve
Cable length max. 700 m (0.43 miles),
at Ø 0.8 mm (0.03 inch) lead

Technical specifications Approvals / marking


Number of leak detectors
max. 10
per line
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
Weight 10 g (0.02 lbs)
28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)

Card MVA LÖ Part no.: 782239


Module for monitoring the feed cable and the solenoid of a
solenoid valve for wire break and short circuit. The card is
integrated in the valve connection box. Monitoring and
triggering must be carried out with a primary control group.

Connection / mounting
Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (AWG 13), dolid conductor
Technical specifications max. 1.5 mm2 (AWG 15), strand with wire end sleeve
The contents of this publication are subject to modifications without notice. All rights reserved.

Input voltage:
- Triggering 17 V - 29 V DC Approvals / marking
- Monitoring 0 V - 10 V DC
Current carrying capacity max. 2 A
Rated capacity of the
max. 38 W
solenoid valve at 24 V
Display, triggering 1 LED red
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
Weight 10 g (0.02 lbs)
311-820_001 / AI00_2015en

28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 55
Product Sheet | Detecon

Standard detectors
Modules, conventional

MVA LÖ redundant card Part no.: 904585


Using the monitoring module the feed lines to the coil
of a solenoid valve or trigger magnets are monitored
for discontinuity and short circuit and whether the coil is
connected. The module must be used for monitoring when a
trigger element in a fire extinguishing system is responsible
for several extinguishing zones and therefore the control and
the feed lines have to be solved in a redundant design.
The module must be used within the connection housing
of the valve.

Connection / mounting
Recommended cable 2-wire
Conductor cross-section
max. 2.5 mm2 (AWG 13), solid conductor
Technical specifications max. 1.5 mm2 (AWG 15), flexible wire with ferrule
Input voltage
- Activation 17 V - 29 V DC
- Monitoring 0 V - 10 V DC
Note
To monitor and control the triggering, two control groups
Current carrying capacity max. 2 A
of two different control group modules must be used.
Power rating of
max. 38 W
solenoid valve at 24 V
Approvals / marking
Anzeige, Ansteuerung 1 LED red
-20 °C to + 50 °C
Operating temperature
(-4 °F to +122 °F)
Weight 10 g (0.02 lbs)
28 x 28 mm (LxW)
Dimensions
1.1 x 1.1 inch (LxW)

Card module sounder Part no.: 782240


Module for monitoring the feed cable of an optical and
acoustic alarm device for wire break and short circuit. The
card must be installed into the housing of each alarm device.

Connection / mounting
Connection cable 2-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
The contents of this publication are subject to modifications without notice. All rights reserved.

Conductor cross-section
max. 2.5 mm2 (AWG 13), solid conductor
max. 1.5 mm2 (AWG 15), strand with wire end sleeve

Technical specifications Approvals / marking


Input voltage:
- Triggering 19 V - 29 V DC
- Monitoring 0 V - 10 V DC
Current carrying capacity max. 0.5 A
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
311-820_002 / AI00_2015en

Weight 20 g (0.04 lbs)


80 x 40 mm (LxB)
Dimensions
3.2 x 1.6 inch (LxB)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 56
Product Sheet | Detecon

Standard detectors
Modules, conventional

Card MVA impulse Part no.: 800112


Module for monitoring the feed cable and the solenoid
of a 2/2-way solenoid valve of the impulse type for wire
break and short circuit. The „NC solenoid“ is also connected
to the card. The card is integrated in the valve connection
box. Monitoring and triggering must be carried out with a
primary control group.

Connection / mounting
Connection cable 3-wire
Recommended cable, standard 747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (AWG 13), solid conductor
max. 1.5 mm2 (AWG 15), strand with wire end sleeve
Technical specifications
Input voltage:
- Triggering 19 V - 29 V DC Approvals / marking
- Monitoring 0 V - 10 V DC
Current carrying capacity max. 2 A
Display, triggering 1 LED red
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F)
Weight 10 g (0.02 lbs)
28 x 28 mm (LxB)
Dimensions
1.1 x 1.1 inch (LxB)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-820_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 57
Product Sheet | Detecon

Standard detectors
Test equipment

Multifunction tester S1000 Part no.: 908595


Smoke & heat detector The multistimulus detector tester S1000 is intended for the
functional testing of point-type fire detectors with single or
multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
Product features keys and displayed on the screen. Compared to the areosol
• Generation of smoke and heat during one only test cans the smoke capsule offers higher test capacities.
• Easier and speedier maintenance procedure
• Used for optical smoke detectors, ionisation Included in delivery
smoke detectors and heat detectors (differential 1 Smoke and heat detector tester head unit only
and maximum detectors) 1 Smoke capsule
• Reduction of testing periods
• Increased testing capacity of the smoke capsules Note
• Automatic infrared identification of the detector Only heat detectors with a release temperature of
• Colour code LED for feedback to the operator up to 60 °C (140 °F) can be tested.
• Top adjustable in several positions
• Optimised method for smoke generation Approvals / marking

Technical specifications
IP rating IP 20
+5 °C to +45 °C
Working temperature
(+41 °F to +113 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Relative humidity 0 to 85 %,
(IEC 721-3-3) no condensation
Weight 750 g (1.7 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

153 x 397 mm (WxH)


Dimensions
6 x 15.6 inch (WxH)
311-911_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 58
Product Sheet | Detecon

Standard detectors
Test equipment

Multifunction test set S1001 Part no.: 908596


Smoke & heat detector The multistimulus detector tester kit S1001 is intended for
the functional testing of point-type fire detectors with single
or multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
Product features keys and displayed on the screen. Compared to the areosol
• Generation of smoke and heat during one only test run cans the smoke capsule offers higher test capacities.
• Easier and speedier maintenance procedure
• Used for optical smoke detectors, ionisation Included in delivery
smoke detectors and heat detectors (differential 1 Smoke and heat detector tester head unit only
and maximum detector) 1 Smoke capsule
2 NiMH battery packs
• Reduction of testing periods
1 Rapid charger 220/240 V AC; 12 V DC
• Increased testing capacity of the smoke capsules
• Automatic infrared identification of the detector Note
• Colour code LED for feedback to the operator Only heat detectors with a release temperature of up to 60 °C
• Top adjustable in several positions (140 °F) are testable

• Optimised method for smoke generation


Approvals / marking

Technical specifications
Battery charging time 75 - 90 min.
Battery baton 7.2 V 2.2 Ah NiMH
IP rating IP 20
+5 °C to +45 °C
Working temperature
(+41 °F to +113 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity 0 to 85 %,
(IEC 721-3-3) no condensation
Weight 1250 g (2.8 lbs)
153 x 397 mm (WxH)
Dimensions
6 x 15.4 inch (WxH)
311-911_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 59
Product Sheet | Detecon

Standard detectors
Test equipment

Smoke detector test kit S834 Part no.: 906947


The universal device kit with extendable fibreglass poles
for testing smoke detectors up to a height of approx. 6 m
(374 inch). The smoke detector testing device can be used
with the SA3 aerosol for all smoke detectors. The swivel
frame also facilitates the testing of detectors that are difficult
to access. The test aerosol is released by touch, with a
patented membrane allowing the efficient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
the detectors, residue-free use, rapid clearing and low
consumption.

Product features Included in delivery


• Universal gripper for removing / mounting detectors 1 Telescopic pole 4.5 m (177.16 inch)
1 Smoke detector testing device
• Telescopic poles for working heights of up to 6 m 2 Carrying bags
(374 inch)
• Smoke detector tester for optical and
ionisation smoke detectors

Technical specifications
Max. working height approx. 6 m (236 inch)
+10 °C to +35 °C
Working temperature
(+50 °F to +95 °F)
- 10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Weight 2210 g (4.9 lbs)
Size of bag for 100 x 1290 mm (dia. x L)
telescopic poles 3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-911_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 60
Product Sheet | Detecon

Standard detectors
Test equipment

Smoke detector test kit S811 Part no.: 906946


The universal device kit includes everything needed for
removing, inserting and testing smoke detectors.
Extendable fibreglass poles are for testing and installing
detectors up to a height of approx. 6 m. By adjusting the
three-point gripper a six-stage division for different detector
diameters is possible.The smoke detector testing device
can be used with the SA3 aerosol for all smoke detectors.
The swivel frame also facilitates the testing of detectors
that are difficult to access. The test aerosol is released by
touch, with a patented membrane allowing the efficient use
of the aerosol. The aerosol is designed for use with the
smoke detector testing device to test ionisation and optical
smoke detectors. Features of the aerosol include reliable test
triggering of the detectors, residue-free use, rapid clearing
Product features and low consumption.
• Universal gripper for removing / mounting detectors
• Telescopic poles for working heights of up to 6 m Included in delivery
(374 inch) 1 Telescopic pole 4.5 m (177.16 inch)
• Smoke detector tester for optical and 1 Detector removal tool
ionisation smoke detectors 1 Smoke detector testing device
2 Carrying bags

Technical specifications
Adjustment range 65 mm to 110 mm
of three-point gripper (2.56 inch to 4.33 inch)
Max. working height approx. 6 m (236.22 inch)
+10 °C to +45 °C
Working temperature
(+50 °F to +95 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122°F)
Weight 3310 g (7.3 lbs)
Size of bag for 100 x 1290 mm (dia. x L)
telescopic poles 3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-911_004/ AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 61
Product Sheet | Detecon

Standard detectors
Test equipment

Heat detector test kit S461 Part no.: 901340


Fully automated, battery-operated heat detector testing
device. Easy to use and energy-saving thanks to activation
of the heating process when the testing device is placed
on the detector. The detector test is carried out completely
flame-free through the use of a warm stream of air horizontal
to the testing head cup. This stream of air comes into direct
contact with the sensor chamber, allowing the detector’s
alarm to be triggered rapidly and in a reproducible manner.

Product features Included in delivery


• Heat radiation without an open flame 1 Heat detector testing device
2 Batteries
• Battery operated
1 Rapid charger 220/240 V AC; 12 V DC
• Rapid battery charger for 230V AC or 12V DC
on-board power supply
• Red and green LEDs for testing status indication
• Testing time limit of max. 120 seconds
• Internal fan cools down heating element
• Energy efficiency mode, automatic shutdown after
5 minutes of inactivity

Technical specifications
Capacity 50 tests, 30 seconds each
Rapid battery charge 75 - 90 minutes
+5 °C to +45 °C
Working temperature
(+41 °F to +113 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Relative humidity 0 to 85 %,
(IEC 721-3-3) no condensation
Weight 1100 g (2.4 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

135 x 330 mm (dia. x L)


Dimensions
5.3 x 13 inch (dia. x L)
311-911_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 62
Product Sheet | Detecon

Standard detectors
Test equipment

Smoke & heat detector test kit S823 Part no.: 906948
The complete device kit includes everything needed for
removing, replacing and testing smoke and heat detectors.
Extendable fibreglass poles are for testing and installing
detectors up to a height of approx. 9,3 m (366 inch).
By adjusting the three-point gripper a six-stage division for
different detector diameters is possible.
The detector test is carried out completely flame-free through
the use of a warm stream of air horizontal to the testing head
cup. This stream of air comes into direct contact with the
sensor chamber, allowing the detector’s alarm to be triggered
rapidly and in a reproducible manner.
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The test aerosol is
released by touch, with a patented membrane allowing the
Product features efficient use of the aerosol.
• Universal gripper for removing / mounting detectors The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
• Heat detector test, battery-operated,
Features of the aerosol include reliable test triggering of
without an open flame
the detectors, residue-free use, rapid clearing and low
• Telescopic poles for working heights of up to 9.3 m consumption.
(366 inch)
• Smoke detector tester for optical and Included in delivery
ionisation smoke detectors
3 Telescopic poles 1.1 m (43.30 inch)
1 Telescopic pole 4.5 m (177.16 inch)
1 Detector removal tool
1 Smoke detector testing device
Technical specifications
1 Heat detector testing device
Adjustment range 65 mm to 110 mm 2 Batteries
of three-point gripper (2.56 inch to 4.33 inch) 1 Rapid charger 220/240 V AC; 12 V DC
Dimensions of heat detector 135 x 330 mm (dia. x L) 2 Carrying bags
tester 5.3 x 13 inch (dia. x L)
Capacity heat detector tester 50 tests, 30 seconds each
Rapid battery charge 75 - 90 minutes
Max. working height approx. 9.3 m (366 inch)
+10 °C to +35 °C
Working temperature
(+50 °F to +95 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Relative humidity 0 to 85 %,
The contents of this publication are subject to modifications without notice. All rights reserved.

(IEC 721-3-3) no condensation


Weight 3300 g (7.3 lbs)
Size of bag for 100 x 1290 mm (dia. x L)
telescopic poles 3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
311-911_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 63
Product Sheet | Detecon

Standard detectors
Test equipment

Test clamp WMX D Part no.: 719857


Function test of differential/maximum heat detectors
of open design (WMX type D).

Note
This procedure is a substitute for a coarse heat test, as
the release resistance is adapted to the specific type and
a detector would not respond if the heat detector or any
other important component is defective.

Not included in delivery


Pipe extension service devices 756549

Technical specifications
Weight 380 g (0.8 lbs)
75 x 118 x 85 mm (LxWxH)
Dimensions
3 x 4.7 x 3.4 inch (LxWxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
311-911_007 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 64
Product Sheet | Detecon

Standard detectors
Test equipment, accessories

Telescopic pole 1.1 m (43 inch) Part no.: 901344

Telescopic pole 2.5 m (98 inch) Part no.: 906951

Telescopic pole 4.5 m (177 inch) Part no.: 901345

Carrying bag for telescopic poles Part no.: 906952

Detector removal tool Part no.: 906955

Set of batteries Part no.: 906954

Rapid charger 220/240 V AC, 12 V DC Part no.: 906953

Silicone membrane for testing cup Part no.: 906949


For S834, S811, S461 and S823

Aerosol retaining cup Part no.: 906950


For S834, S811 and S823

Test aerosol SA3 Part no.: 905904


For S834, S811 and S823

Smoke capsule Part no.: 908597


For S1000 and S1001

Test fire mat type 1640 Part no.: 723014


The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Operational test
Material PU foam
Gaseous combustion
products: Not included in delivery
Carbon dioxide, Base e.g. aluminium foil
Carbon monoxide 1.55 Vol.%, 1.21 Vol.%
Methane, Ethane 0.41 Vol.%, 0.02 Vol.%
Propane, Ethylene 0.01 Vol.%, 0.21 Vol.% Note
Propylene, Acetylen 0.11 Vol.%, 0.03 Vol.% Customers permission for burning the mat required.
Hydrochlorid acid, Aerosols may effect electronic devices. Pollution of magnetic
Fluoride acid not
mass storages.
Nitrous gases 0.035 mg/l
311-914_001 / AI01_2016en

Ammonia and Organic


bases, 0.16 mg/l
traces of Hydrocyamic acid
Weight 70 g (0.15 lbs)
500 x 400 x 20 mm (WxHxD)
Dimensions
19.68 x 15.74 x 0.78 inch (WxHxD)
1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 65
Product Sheet | Detecon

Standard detectors
Test equipment, accessories

Universal detector removal tool S200 Part no.: 922506

Smoke detector testing device S330 Part no.: 922505


The contents of this publication are subject to modifications without notice. All rights reserved.
311-914_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 5 - 66
Product Sheet | Detecon

Industrial detectors
UniVario – Versatile in application

UniVario FMX5000 IR
3-channel infrared flame detector with three-way optics test
for complete function monitoring. Very high responsivity
and filtering of interfrence such as sunlight and hot surfaces
through intelligent evaluation algorithms

UniVario FMX5000 UV
Flame detector with spectral sensitivity in the ultraviolet
range. High response sensitivity with monitoring area
up to 676 m2. Interference such as cosmic radiation and
thunderstorms (lightning) is filtered out intelligent evaluation
algorithms with integrated self-testing for monitoring the
functionality (optical test).

UniVario WMX5000
Heat detector with a robust stainless steel heat sensor.
A microcontroller monitors the functionality and analyses
data. The detector can be freely configured for any
application. For this, response temperatures, response
classes and indices can be adjusted. Can be expanded by
adding an LCD display.

UniVario WMX5000 FS
Heat detector for heavy-duty daily use with a robust stainless
steel heat sensor rod or flexible hose which protrudes
from the enclosure. Thermoelectric sensors for response
temperatures up to 850 °C (1562 °F). A microcontroller
monitors the functionality and analyses data. Prominent
response temperatures and all response classes can be
freely configured, along with rate-of-rise and static (fixed
temperature) response behaviour. Can be expanded by
adding an LCD display.

UniVario
A family of industrial fire detectors based on a uniform platform. Highly variable, with a modular system for maximum adaptability.

Conventional detectors are available and can be changed to analogue addressable detectors by adding the communication
module KMX5000 AP / KMX5000 AP Ex.
The contents of this publication are subject to modifications without notice. All rights reserved.

To achieve the best possible protection in each individual scenario, fire detectors of different designs and response sensitivity
are used according to the requirements of each protected site. Even for Off-shore applications are stainless steel versions
available. They work indoors and outdoors; in the direct vicinity of the protected site like UniVario WMX5000, or from further
afield like UniVario FMX5000 UV; in clean room environments as well as in extremely dirty process conditions. Equipped
internally with the very latest advanced technology, they also feature a robust and attractive enclosure design. This new
generation of high-tech fire detectors is substantially prefabricated, is easy and quick to install and can be easily integrated into
existing solutions, making them an affordable alternative to conventional systems. One major advantage of the new range is
their ability to forward detector data to databases for the purposes of analysis, maintenance or statistics compilation.
Variations of UniVario detectors for conventional lines or analogue addressable systems are available, well graded for different
hazard areas. The UniVario detector series with state of the art technology has big advantages due to lower installation costs in
analogue addressable systems and increased safety due to permanent data transfer between control panel and detectors.
312-010_001 / AI01_2016en

1/5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 1
Product Sheet | Detecon

Industrial detectors
UniVario – Versatile in application

Overview accessories UniVario

Bracket Console Base Base 3M16 Base LCD Base+Isolator Relay module Comms module Service device

F
FMX5000 IR

Bracket Base
HR HR
FMX5000 IR HR

F
FMX5000 UV

F
FMX5000 UVs

W
WMX5000

W
WMX5000 FS

W
WMX5000 FS Flex

W
WMX5000 single hole

F
WMX5000 VA
The contents of this publication are subject to modifications without notice. All rights reserved.
312-010_001 / AI01_2016en

2/5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 2
Product Sheet | Detecon

Industrial detectors
UniVario – Versatile in application

Overview accessories UniVario

Ex barrier Bracket Console Base Ex Comms Comms Service


module module Ex device
3GD

F *1
FMX5000 IR 3GD

2G1D

F
FMX5000 IR Ex
3GD

F *1
FMX5000 UV 3GD
*1) This service device should only be used outside of the explosion hazardous zone
The contents of this publication are subject to modifications without notice. All rights reserved.
312-010_001 / AI01_2016en

3/5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 3
Product Sheet | Detecon

Industrial detectors
UniVario – Versatile in application

Overview accessories UniVario

Ex barrier Bracket Console Base Ex Comms Comms Service


module module Ex device
3GD

W *1
WMX5000 3GD
2G1D

W
WMX5000 Ex

3GD

W *1
WMX5000 FS 3GD

2G1D

W
WMX5000 FS Ex
3GD

W *1
WMX5000 FS Flex 3GD
2G1D

W
WMX5000 FS Flex Ex
3GD

W *1
WMX5000 single hole 3GD
2G1D

W
WMX5000 single hole Ex
*1) The service device should only be used outside of the explosion hazardous zone
The contents of this publication are subject to modifications without notice. All rights reserved.
312-010_001 / AI01_2016en

4/5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 4
Product Sheet | Detecon

Industrial detectors
UniVario – Versatile in application

Overview accessories UniVario

Ex barrier Mounting bracket Base Comm.


MX5000 ST MX5000 ST module Ex
1GD

FMX5000 IR Ex ST
1GD

WMX5000 Ex ST

1GD

WMX5000 Einloch Ex ST
1GD

WMX5000 FS Ex ST
1GD

WMX5000 FS Flex Ex ST
The contents of this publication are subject to modifications without notice. All rights reserved.
312-010_001 / AI01_2016en

5/5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 5
Product Sheet | Detecon

Industrial detectors
UniVario IR flame detector

FMX5000 IR Part no.: 907481


Triple IR flame detector for the detection of typical fires.
Including 3 channel optic test monitoring all functional
characteristics of detector. Designed for use in rough
industrial environments. Equipped for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Remote indicator LMX5000 908499
e.g. from hot surfaces or sunlight Weather protection MX5000 complete 910134
Relay module KMX5000 RK 906361
• A microcontroller monitors the functionality
KMX5000 AP communication module 905883
and analyses the recorded data. Faults can be
Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory
Not included in delivery
• Connection of remote indicator possible
Base UniVario MX5000 904701
• 3-channel optic test Bracket MX5000 904757
Terminating resistor 1.8 K / 0.5 W 675235

Technical specifications Spare part


Reflector ring 908351
Detection method 3 IR Sensors
adjustable x (50 m (164 ft))
Sensitivity class Connection / mounting
1, 2, 3
Connection cable standard detector 2-wire
Viewing angle 90°
Additional fault line connection 2-wire
Operating voltage 7.6 V - 30 V DC External indication  2-wire
Quiescent current 2.3 mA Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Alarm current approx. 15 mA
Conductor cross-section max. 2.5 mm2 (AWG 13)

Alarm indication 1 LED red


Fault indication current approx. 15 mA
Approvals / marking
Fault indication 1 LED yellow
The contents of this publication are subject to modifications without notice. All rights reserved.

G 209141 0786-CPR-20784
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)
312-330_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 6
Product Sheet | Detecon

Industrial detectors
UniVario IR flame detector

FMX5000 IR HR Part no.: 909404


Triple IR flame detector for the detection of typical fires.
Including 3 channel optic test monitoring all functional
characteristics of detector. Variante HR (high ressistance)
designed for use in highly rough industrial environments
such as chemical industry. Designed for operation as a
conventional detector.Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Remote indicator LMX5000  908499
e.g. from hot surfaces or sunlight Weather protection MX5000 complete 910134
KMX5000 AP communication module 905883
• A microcontroller monitors the functionality
Relay module KMX5000 RK 906361
and analyses the recorded data. Faults can be
Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory
Not included in delivery
• Connection of remote indicator possible
Base UniVario MX5000 HR 909406
• 3-channel optic test Bracket MX5000 HR 909359
Terminating resistor 1.8 K / 0.5 W 675235

Technical specifications Connection / mounting


Connection cable standard detector 2-wire
Detection method 3 IR Sensors
Additional fault line connection 2-wire
adjustable x (50 m (164 ft)) External indication  2-wire
Sensitivity class
1, 2, 3 Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch)
Viewing angle 90°
Operating voltage 7.6 V - 30 V DC
Approvals / marking
Quiescent current 2.3 mA
Alarm current approx. 15 mA G 209141 0786-CPR-20784
Alarm indication 1 LED red
Fault indication current approx. 15 mA
Fault indication 1 LED yellow
The contents of this publication are subject to modifications without notice. All rights reserved.

-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)
312-330_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 7
Product Sheet | Detecon

Industrial detectors
UniVario UV flame detector

FMX5000 UV Part no.: 904702


UV flame detector for the detection of typical fires.
Including UV optic test monitoring all functional
characteristics of detector. Designed for use in rough
industrial environments. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Remote indicator  908499
such as storm lightning or strong sunlight Weather protection MX5000 complete 910134
KMX5000 AP communication module 905883
• A microcontroller monitors the functionality
Relay module KMX5000 RK 906361
and analyses the recorded data. Faults can be
Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory
• Connection of remote indicator possible Not included in delivery
Base UniVario MX5000 904701
Bracket MX5000 904757
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method UV sensor Spare part
Sensitivity class 1 Protecting cage 904284
Viewing angle 90°
Operating voltage 7.6 V - 30 V DC Connection / mounting
Connection cable standard detector 2-wire
Quiescent current approx. 0.25 mA
Additional fault line connection 2-wire
Alarm current approx. 15 mA External indication  2-wire
Alarm indication 1 red LED Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (AWG 13)
Fault indication current approx. 15 mA
Fault indication 1 yellow LED
-20 °C to +80 °C
Approvals / marking
Operating temperature
(-4 °F to +176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 67 G 206132 0786-CPR-20286

Enclosure material Diecast aluminium


Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)
312-310_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 8
Product Sheet | Detecon

Industrial detectors
UniVario UV flame detector

FMX5000 UVs Part no.: 907375


UV flame detector for the detection of typical fires.
Designed for use in rough industrial environments.
Designed for operation as a conventional detector.
Expansion for a detector with Loop AP protocol via
KMX5000 AP communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Remote indicator  908499
such as storm lightning or strong sunlight Weather protection MX5000 complete 910134
KMX5000 AP communication module 905883
• A microcontroller monitors the functionality
Relay module KMX5000 RK 906361
and analyses the recorded data. Faults can be
Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory
• Connection of external signal indication possible Not included in delivery
Base UniVario MX5000 904701
Bracket MX5000 904757
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method UV sensor Connection / mounting
Sensitivity class 1 Connection cable standard detector 2-wire
Additional fault line connection 2-wire
Viewing angle 90°
External indication  2-wire
Operating voltage 7.6 V - 30 V DC Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Quiescent current approx. 0.25 mA Conductor cross-section max. 2.5 mm2 (AWG 13)
Alarm current approx. 15 mA
Alarm indication 1 red LED Approvals / marking
Fault indication current approx. 15 mA
G 206132 0786-CPR-20286
Fault indication 1 yellow LED
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 67


Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)
312-310_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 9
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, standard

WMX5000 Part no.: 905441


The WMX5000 heat detectors are designed to detect
open fires with rapid rise of temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
They are designed specifically for operation in polluted
industrial environments, both indoors and outdoors. In
addition to static temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat sensor, Remote indicator  908499
resistant against impact and vibration Weather protection MX5000 complete 910134
KMX5000 AP communication module 905883
• Freely configurable response temperatures and classes in Relay module KMX5000 RK 906361
accordance with EN 54-5, along with rate-of-rise and static Silicone-free design
responses. Configuration via DIP switches on the detector
• Service interface, history memory
Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Bracket MX5000 904757
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method NTC sensor
Connection / mounting
Connection cable standard detector 2-wire
Response classes A1, A2, B, C, indices S, R
Additional fault line connection 2-wire
0 °C to +90 °C Remote indication  2-wire
Response temperatures
(+32 °F to +194 °F) Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch)
Operating voltage 7.6 V - 30 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Quiescent current approx. 0.15 mA
Alarm current consumption approx. 15 mA Approvals / marking
Alarm indication 1 red LED
Normal operation indication 1 green LED, flashing G 207090 0786-CPR-20280
Fault indication current approx. 15 mA
Fault indication 1 yellow LED (2nd line)
-20 °C to +80 °C
The contents of this publication are subject to modifications without notice. All rights reserved.

Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 520 g (1.2 lbs)
130 x 84 mm (dia. x H)
Dimensions
5.1 x 3.3 inch (dia. x H)
312-110_001 / AI01_2016en

WMX5000 CN Part no.: 909375


Version China Approvals / marking
Technical data see part no. 905441

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 10
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, standard

UniVario WMX5000 single hole Part no.: 905847


The single hole mounted WMX5000 heat detectors are
specifically designed for use in dryer and ventilation ducts for
the detection of fires with rapid rise in temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
In addition to fixed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat sensor, Remote indicator  908499
resistant to impact and vibration Weather protection MX5000 complete 910134
KMX5000 AP communication module 905883
• Freely configurable response temperatures and classes in Relay module KMX5000 RK 906361
accordance with EN 54-5, along with rate-of-rise and static Silicone-free design
responses. Configuration via DIP switches on the detector
• Service interface, history memory
Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Single hole mounting fixture 800034
Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method NTC sensor
Connection / mounting
Response classes A1, A2, B, C, D indices S, R
Connection cable standard detector 2-wire
0 °C to +105 °C
Response temperatures Additional fault line connection 2-wire
(+32 °F to +221 °F)
Remote indication  2-wire
Operating voltage 7.6 V - 30 V DC Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Quiescent current approx. 0.15 mA Conductor cross-section max. 2.5 mm2 (AWG 13)
Alarm current consumption approx. 15 mA
Alarm indication 1 red LED Approvals / marking
Normal operation indication 1 green LED, flashing
Fault indication current approx. 15 mA
G 207090 0786-CPR-20280
Fault indication 1 yellow LED (2nd line)
-20 °C to +80 °C
The contents of this publication are subject to modifications without notice. All rights reserved.

Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 580 g (1.3 lbs)
130 x 133 mm (dia. x H)
Dimensions
5.1 x 5.2 inch (dia. x H)
312-110_002 / AI01_2016en

WMX5000 single hole CN Part no.: 909376


Version China Approvals / marking
Technical data see part no. 905847

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 11
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS

WMX5000 FS 400°C (752 °F) Part no.: 905505


The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area.
For example in exhaust ducts, engine test stands or machine
tools. In addition to fixed temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat rod sensor Remote indicator  908499
• Freely configurable response temperatures and KMX5000 AP communication module 905883
classes in accordance with EN 54-5, along with Relay module KMX5000 RK 906361
rate-of-rise and static responses. Configuration Silicone-free design
via DIP switches on the detector
• Service interface, history memory Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Single hole mounting fixture 800034
Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method PT1000 sensor Connection / mounting
A1, A2, B, C, D, E, F, G, Connection cable standard detector 2-wire
Response classes
indices S, R Additional fault line connection 2-wire
0 °C to +400 °C Remote indication  2-wire
Response temperatures
(+32 °F to +752 °F) Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Operating voltage 7.6 V - 30 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Quiescent current approx. 0.25 mA
Alarm current consumption approx. 15 mA Note
Alarm indication 1 red LED The desired length of the sensor rod must be specified in
Normal operation indication 1 green LED, flashing millimetres at the time of placing the order. Alternatively,
fixed standard rod lengths are available to choose from.
Fault indication current approx. 15 mA
Fault indication 1 yellow LED (2nd line)
Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67 G 207091 0786-CPR-20281
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
Dimensions
5.1 x 5.9 x 59.1 inch (dia. x H)
312-130_001 / AI01_2016en

WMX5000 FS 400 °C (752 °F) CN Part no.: 909378


Version China Approvals / marking
Otherwise like part no. 905505

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 12
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS

WMX5000 FS 400 °C 200 mm Part no.: 906401


(752 °F 7.9 inch)
Version with fixed rod length of 200 mm (7.9 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 905505
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x 260 mm (dia. x H)
Dimensions
5.1 x 10.2 inch (dia. x H)

WMX5000 FS 400 °C 400 mm Part no.: 906402


(752 °F 15.8 inch)
Version with fixed rod length of 400 mm (15.8 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 905505
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x 460 mm (dia. x H)
Dimensions
5.1 x 18.1 inch (dia. x H)
The contents of this publication are subject to modifications without notice. All rights reserved.

WMX5000 FS 400 °C 600 mm Part no.: 906403


(752 °F 23.6 inch)
Version with fixed rod length of 600 mm (33.6 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 905505
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
Dimensions
312-130_001 / AI01_2016en

5.1 x 26 inch (dia. x H)

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 13
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS

WMX5000 FS 850°C (1562 °F) Part no.: 906454


The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to fixed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat rod sensor Remote indicator  908499
• Freely configurable response temperatures and KMX5000 AP communication module 905883
classes in accordance with EN 54-5, along with Relay module KMX5000 RK 906361
rate-of-rise and static responses. Configuration Silicone-free design
via DIP switches on the detector
• Service interface, history memory Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Single hole mounting fixture 800034
Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method PT1000 sensor Connection / mounting
A1, A2, B, C, D, E, F, G, Connection cable standard detector 2-wire
Response classes
indices S, R Additional fault line connection 2-wire
0 °C to +840 °C Remote indication  2-wire
Response temperatures
(+32 °F to +1544 °F) Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Operating voltage 7.6 V - 30 V DC
Conductor cross-section max. 2.5 mm2 (AWG 13)

Quiescent current approx. 0.35 mA


Note
Alarm current consumption approx. 15 mA
The desired length of the sensor rod must be specified
Alarm indication 1 red LED in millimetres at the time of placing the order.
Normal operation indication 1 green LED, flashing
Fault indication current approx. 15 mA Approvals / marking
1 yellow LED (2nd line)
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
Dimensions
5.1 x 5.9 x 59.1 inch (dia. x H)
312-130_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 14
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex

WMX5000 FS Flex 400°C (752 °F) Part no.: 906176


The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area.
For example in exhaust ducts, engine test stands or machine
tools. In addition to fixed temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via KMX5000 AP communication module.

Product features Optional accessories


• Robust flexible stainless steel heat sensor Remote indicator  908499
• Freely configurable response temperatures KMX5000 AP communication module 905883
and classes in accordance with EN 54-5, along Relay module KMX5000 RK 906361
with rate-of-rise and static responses. Configuration Silicone-free design
via DIP switches on the detector
• Service interface, history memory Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Holder WMX FS, from
250 °C (482 °F) to 600 °C (1112 °F) 894679
Terminating resistor 1.8 K / 0.5 W  675235
Technical specifications
Detection method PT1000 sensor Connection / mounting
A1, A2, B, C, D, E, F, G, Connection cable standard detector 2-wire
Response classes
indices S, R Additional fault line connection 2-wire
0 °C to +400 °C Remote indication  2-wire
Response temperatures
(+32 °F to +752 °F) Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Operating voltage 7.6 V - 30 V DC
Conductor cross-section max. 2.5 mm2 (AWG 13)

Quiescent current approx. 0.25 mA


Alarm current consumption approx. 15 mA
Note
The desired length of the flexible sensor rod must be
Alarm indication 1 red LED specified in metres at the time of placing the order.
Normal operation indication 1 green LED, flashing The sensor rod holder is designed for application
Fault indication current approx. 15 mA temperatures of up to 250 °C (482 °F). In case of higher
application temperatures, the holder WMX FS from 250 °C
1 yellow LED (2nd line)
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication (482 °F) to 600°C (1112 °F) Part no. 804679 is to be used.
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Approvals / marking
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
G 207091 0786-CPR-20281
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
Dimensions
5.1 x 78.7 x 354.3 inch (dia. x H)
312-150_001 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 15
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex

WMX5000 FS Flex 400 °C 2 m Part no.: 906404


(752 °F 79 inch)
Version with flexible hose of 2 m length (79 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 906176
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
Dimensions
5.1 x up to 78.73 inch (dia. x H)

WMX5000 FS Flex 400 °C 6 m Part no.: 906405


(752 °F 236 inch)
Version with flexible hose of 6 m length (236 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 906176
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
Dimensions
5.1 x up to 236.2 inch (dia. x H)

WMX5000 FS Flex 400 °C 9 m Part no.: 906406


The contents of this publication are subject to modifications without notice. All rights reserved.

(752 °F 354 inch)


Version with flexible hose of 9 m length (354 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 906176
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
312-150_001 / AI01_2016en

Dimensions
5.1 x up to 354.3 inch (dia. x H)

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 16
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex

WMX5000 FS Flex 850°C (1562 °F) Part no.: 906455


The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area.
For example in exhaust ducts, engine test stands or
machine tools. In addition to fixed temperature detection,
rapid rises in temperature can also be registered by the
rate-of-rise method, for early fire detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via
KMX5000 AP communication module.

Product features Optional accessories


• Robust flexible stainless steel heat sensor Remote indicator  908499
• Freely configurable response temperatures KMX5000 AP communication module 905883
and classes in accordance with EN 54-5, Relay module KMX5000 RK 906361
along with rate-of-rise and static responses. Silicone-free design
Configuration via DIP switches on the detector
• Service interface, history memory Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 904701
Terminating resistor 1.8 K / 0.5 W 675235

Technical specifications Connection / mounting


Connection cable standard detector 2-wire
Detection method PT1000 sensor Additional fault line connection 2-wire
A1, A2, B, C, D, E, F, G, Remote indication  2-wire
Response classes
indices S, R Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
0 °C to +840 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Response temperatures
(+32 °F to +1544 °F)
Operating voltage 7.6 V - 30 V DC Note
Quiescent current approx. 0.35 mA The desired length of the flexible sensor rod must be
specified in metres at the time of placing the order.
Alarm current consumption approx. 15 mA
Alarm indication 1 red LED
Approvals / marking
Normal operation indication 1 green LED, flashing
Fault indication current approx. 15 mA
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication 1 yellow LED (2nd line)


-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
Dimensions
5.1 x 78.7 x 354.3 inch (dia. x H)
312-150_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 17
Product Sheet | Detecon

Industrial detectors
UniVario IR flame detector, Ex

UniVario FMX5000 IR 3GD Part no.: 909481


Triple IR flame detector for the detection of typcal fires.
Including 3 channel optic test monitoring all functionalties
of detector. ATEX-approved for category 3, Gas and Dust,
suitable for use in Ex zones 2 and 22. The detector must not
connected with a safety barrier and a blue fire alarm cable.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via
KMX5000 AP communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Parallel indicator LMX5000  908499
e.g. from hot surfaces or sunlight KMX5000 AP communication module 905883
• A microcontroller monitors the functionality Weather protection MX5000 complete 910134
and analyses the recorded data. Faults can be Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory Not included in delivery
Base UniVario MX5000 Ex 912082
• Connection of remote indicator possible
Bracket MX5000 904757
• 3-channel optic test Terminating resistor 1.8 K / 0.5 W 675235
• For use in Ex zones 2 and 22,
ATEX category 3 Gas/Dust Connection / mounting
Connection cable standard detector 2-wire
Additional fault line connection 2-wire
External indication  2-wire
Technical specifications
Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Detection method 3 IR Sensors Conductor cross-section max. 2.5 mm2 (AWG 13)
adjustable x (50 m (164 ft))
Sensitivity class
1, 2, 3
Approvals / marking
Viewing angle 90° Ex conformity in acc. with 94/9/EG:
Operating voltage 7.6 V - 30 V DC x II 3G Ex nAc IIC T4
Quiescent current 2.3 mA x II 3D Ex tc IIIC T110°C IP 65
Type examination certificate: BVS 11 ATEX E135
Alarm current approx. 15 mA
Ex conformity Russia in acc. with TP TC 012/2011:
Alarm indication 1 LED red 1Ex ia IIC T6/T4 Gb
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA 0Ex ia IIC T6/T4 Ga


Ex ia IIIC T95°C Da
Fault indication 1 LED yellow
-20 °C to +80 °C
Operating temperature G 209141 0786-CPR-20784
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
312-340_001 / AI01_2016en

100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 18
Product Sheet | Detecon

Industrial detectors
UniVario IR flame detector, Ex

FMX5000 IR Ex Part no.: 911674


Triple IR flame detector for the detection of typical fires.
Including 3 channel optic test monitoring all functionalties of
detector. ATEX and IECEx approved for category 2 Gas
and 1, 2 Dust, suitable for use in Ex zones 1, 20 and 21.
The detectors must be connected via a safety barrier.
Designed for use in tough industrial environments.
Equipped for operation as a conventional detector.
Extension to a detector with Loop AP protocol via the
KMX5000 AP Ex. communication module.

Product features Optional accessories


• High degree of immunity against false alarms, Safety barrier IS conventional 9 V  904991
e.g. from hot surfaces or sunlight Safety barrier IS addressable 24 V 901324
KMX5000 AP Ex communication module 912086
• A microcontroller monitors the functionality
Weather protection MX5000 complete  910134
and analyses the recorded data. Faults can be
Silicone-free design
indicated on the detector or on a separate line
• Service interface, history memory
Not included in delivery
• Connection of remote indicator possible
Base UniVario MX5000 Ex 912082
• 3-channel optic test Bracket MX5000 904757
• For use in Ex zones 1, 20 and 21, Terminating resistor 1.8 K / 0.5 W 675235
ATEX category 2 Gas/1, 2 Dust
Connection / mounting
Connection cable standard detector 2-wire
Technical specifications Additional fault line connection 2-wire
External indication 2-wire
Detection method 3 IR Sensors Recommended cable JE-Y (St) Y 2x2x0.8 mm (0.03 inch)
adjustable x (50 m (164 ft)) Conductor cross-section max. 2.5 mm2 (AWG 13)
Sensitivity class
1, 2, 3
Viewing angle 90° Approvals / marking
Operating voltage 7.6 V - 30 V DC Ex conformity in acc. with 94/9/EG:
Quiescent current 4.5 mA x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
Alarm current approx. 15 mA
Type examination certificate: BVS 12 ATEX E088
Alarm indication 1 LED red IECEx conformity: IECEx BVS 12.0056
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA Ex conformity Russia in acc. with TP TC 012/2011:


1Ex ia IIC T6/T4 Gb
Fault indication 1 LED yellow
0Ex ia IIC T6/T4 Ga
-25 °C to +80 °C Ex ia IIIC T95°C Da
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 67
G 209141 0786-CPR-20784
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 860 g (1.9 lbs)
312-340_002 / AI01_2016en

100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 19
Product Sheet | Detecon

Industrial detectors
UniVario IR flame detector, Ex

FMX5000 IR Ex ST Part no.: 916255


Triple IR flame detector for the detection of typical fires.
Including 3 channel optic test monitoring all functionalties of
detector. ATEX and IECEx approved for category 1, 2, 3 Gas
and 1, 2, 3 Dust, suitable for use in Ex zones 0, 1, 20, 21
and 22.The detectors must be connected via a safety barrier.
Designed for use in tough industrial environments and
Off-shore applications. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP Ex. communication module.

Product features Optional accessories


• Stainless steel version V4A Safety barrier IS conventional 9 V  904991
• High degree of immunity against false alarms, Safety barrier IS addressable 24 V 901324
e.g. from hot surfaces or sunlight KMX5000 AP Ex communication module 912086
Weather protection MX5000 complete  910134
• A microcontroller monitors the functionality Silicone-free design
and analyses the recorded data. Faults can be
indicated on the detector or on a separate line
Not included in delivery
• Service interface, history memory
Base UniVario MX5000 ST 916173
• 3-channel optic test Mounting bracket MX5000 ST 914914
• For use in Ex zones 0, 1, 20, 21 and 22, Terminating resistor 1.8 K / 0.5 W 675235
ATEX category 1, 2, 3 Gas/1, 2, 3 Dust
Connection / mounting
Connection cable standard detector  2-wire
Technical specifications Additional fault line connection 2-wire
Remote indication  2-wire
Detection method 3 IR Sensors Recommended cable  JE-Y(St)Y 2x2x0.8 mm (0.03 inch), blue Ex
adjustable x (50 m (164 ft)) Conductor cross-section  max. 2.5 mm2 (AWG 13)
Sensitivity class
1, 2, 3
Viewing angle 90° Approvals / marking
Operating voltage 7.6 V - 30 V DC Ex conformity in acc. with 94/9/EG:
Quiescent current 4.5 mA x II 1G Ex ia IIC T6/T4 Ga
Alarm current approx. 15 mA x II 1D Ex ia IIIC T95°C Da
Type examination certificate: BVS 12 ATEX E 088
Alarm indication 1 LED red IECEx conformity: IECEx BVS 12.0056
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA


Fault indication 1 LED yellow
G 209141 0786-CPR-20784
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Stainless steel (saltwater-proof)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 1000 g (2.2 lbs)
312-340_003 / AI01_2016en

130 x 50 mm (dia. x H)
Dimensions
5.1 x 2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 20
Product Sheet | Detecon

Industrial detectors
UniVario UV flame detector, Ex

FMX5000 UV 3GD Part no.: 907267


UV flame detector for detection of typical fires. Designed
for use in harsh industrial environments. Fitted for use as
a conventional detector. The FMX5000 UV 3GD UV flame
detectors are Atex approved for Category 3 gas and dust
and are intended for use in Ex Zones 2 and 22. Expansion
to a detector with Loop AP protocol via the KMX5000 AP
communications module. The flame detector features a
built-in optical channel function test.

Product features Optional accessories


• High degree of immunity against false alarms, Remote indicator LMX5000 908499
such as storm lightning or strong sunlight KMX5000 AP communication module 905883
Weather protection MX5000 complete 910134
• Function monitoring and evaluation of measured
Silicone-free design
values by microcontroller, faults can be displayed
on the detector or a separate line
• Service interface, history memory Not included in delivery
• Connection of external display possible Base UniVario MX5000 Ex 912082
Bracket MX5000 904757
• Use in Ex Zones 2 and 22 Atex Categorie 3 gas/dust Terminating resistor 1,8 K / 0,5 W 675235

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Detection method UV-Sensor Additional fault line connection 2-wire
Remote indication  2-wire
Sensitivity class 1
Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Viewing angle 90° Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 7.6 V - 30 V DC
Quiscent current approx. 0.25 mA Approvals / marking
Alarm current approx. 15 mA Ex conformity in acc. with 94/9/EG:
Alarm indication 1 LED red
x II 3G Ex nAc IIC T4
x II 3D Ex tc IIIC T110°C IP65
Fault indication current approx. 15 mA EC type approval certificate: BVS 11 ATEX E137
Fault indication 1 LED yellow Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
The contents of this publication are subject to modifications without notice. All rights reserved.

-20 °C to +80 °C
Operating temperature Ex tc IIIC T110°C IP65
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
G 206132 0786-CPR-20286
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 10
Weight 820 g (1.8 lbs)
100 x 50 mm (dia. x H)
Dimensions
3.9 x 2 inch (dia. x H)
312-320_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 21
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 3GD Part no.: 907268


The WMX5000 3GD heat detectors are ATEX-approved
for category 3, gas and dust, and are suitable for use in
Ex zones 2 and 22. They are designed to detect open fires
with rapid rise of temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
They are designed specifically for operation in dirty industrial
environments, both indoors and outdoors. In addition to
stated temperature detection, rapid rises in temperature can
also be registered by the rate-of-rise method, for early fire
detection. Equipped for operation as a conventional detector.
Extension to a detector with Loop AP protocol via the
KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat sensor Remote indicator  908499
• Freely configurable response temperatures and KMX5000 AP communication module 905883
classes in accordance with EN 54-5, along with Silicone-free design
rate-of-rise and static responses. Setting via DIP
switches on the detector or SMX5000 service device Not included in delivery
• Service interface, history memory Base UniVario MX5000 Ex 912082
• Connection of remote indicator possible Bracket MX5000 904757
• For use in Ex zones 2 and 22, Terminating resistor 1.8 K / 0.5 W 675235
ATEX category 3 Gas/Dust
Connection / mounting
Connection cable standard detector 2-wire
Technical specifications Additional fault line connection 2-wire
Remote indication  2-wire
Detection method NTC sensor Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Response classes A1, A2, B, C, indices S, R Conductor cross-section max. 2.5 mm2 (AWG 13)
0 °C to +90 °C
Response temperatures
(+32 °F to +194 °F) Approvals / marking
Operating voltage 7.6 V - 30 V DC Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4
Quiescent current approx. 0.15 mA x II 3D Ex tD A22 IP 65 T110°C
Type examination certificate: BVS 07 ATEX E 156
Alarm current consumption
approx. 15 mA Ex conformity Russia in acc. with TP TC 012/2011:
(without quiescent current)
2Ex nAc IIC T4
Alarm indication 1 red LED Ex tc IIIC T110°C IP 65
The contents of this publication are subject to modifications without notice. All rights reserved.

Normal operation indication 1 green LED, flashing


Fault indication current approx. 15 mA G 207090 0786-CPR-20280
Fault indication 1 yellow LED (2nd line)
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
312-120_001 / AI01_2016en

Weight 520 g (1.2 lbs)


130 x 84 mm (dia. x H)
Dimensions
5.1 x 3.3 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 22
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 Ex Part no.: 912117


The WMX5000 Ex heat detectors are ATEX and IECEx
approved for category 2 gas and 1,2 dust, and are suitable
for use in Ex zones 1, 20 and 21. They are designed to
detect open fires with rapid rise of temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
They are designed specifically for operation in dirty industrial
environments, both indoors and outdoors. In addition to
stated temperature detection, rapid rises in temperature can
also be registered by the rate-of-rise method, for early fire
detection. Equipped for operation as a conventional detector.
Extension to a detector with Loop AP protocol via the
KMX5000 AP Ex communication module.

Product features Optional accessories


• Robust stainless steel heat sensor Safety barrier IS conventional 9 V  904991
• Freely configurable response temperatures and Safety barrier IS addressable 24 V 901324
classes in accordance with EN 54-5, along with KMX5000 AP Ex communication module 912086
rate-of-rise and static responses. Setting via DIP Weather protection MX5000 complete  910134
switches on the detector or SMX5000 service device Silicone-free design
• Service interface, history memory
• Connection of remote indicator possible Not included in delivery
• For use in Ex zones 1, 20 and 21, Base UniVario MX5000 Ex 912082
ATEX category 2 Gas/1, 2Dust Bracket MX5000 904757
Terminating resistor 1.8 K / 0.5 W 675235

Connection / mounting
Technical specifications
Connection cable standard detector 2-wire
Detection method NTC sensor Additional fault line connection 2-wire
Response classes A1, A2, B, C, indices S, R Remote indication  2-wire
Recommended cable  JE-Y (St) Y 2x2x0.8 mm (0.03 inch)
0 °C to +90 °C
Response temperatures Conductor cross-section max. 2.5 mm2 (AWG 13)
(+32 °F to +194 °F)
Operating voltage 7.6 V - 30 V DC
Approvals / marking
Quiescent current approx. 2.8 mA
Ex conformity in acc. with 94/9/EG:
Alarm current consumption x II 2G Ex ia IIC T6/T4 Gb
approx. 15 mA
(without quiescent current)
x II 1D Ex ia IIIC T95°C Da
Alarm indication 1 red LED Type examination certificate: BVS 12 ATEX E121
The contents of this publication are subject to modifications without notice. All rights reserved.

Normal operation indication 1 green LED, flashing IECEx conformity: IECEx BVS 12.0074
Ex conformity Russia in acc. with TP TC 012/2011:
Fault indication current approx. 15 mA
1Ex ia IIC T6/T4 Gb
Fault indication 1 yellow LED (2nd line) 0Ex ia IIC T6/T4 Ga
-25 °C to +80 °C Ex ia IIIC T95°C Da
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 67
G 207090 0786-CPR-20280
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
312-120_002 / AI01_2016en

Weight 520 g (1.2 lbs)


130 x 84 mm (dia. x H)
Dimensions
5.1 x 3.3 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 23
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 Ex ST NEW Part no.: 916171


The WMX5000 Ex ST heat detectors are ATEX and IECEx
approved for category 1, 2, 3 Gas and 1, 2, 3 Dust, and are
suitable for use in Ex zones 0, 1, 20, 21 and 22. They are
designed to detect open fires with rapid rise of temperature,
e.g.:
– Flammable liquids and gases
– Highly flammable plastics
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection.
The detectors must be connected via a safety barrier.
Designed for use in tough industrial environments and
Off-shore applications. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP Ex communication module.
Product features
• Stainless steel version V4A
• Robust stainless steel heat sensor
Optional accessories
Safety barrier IS conventional 9 V  904991
• Freely configurable response temperatures and
Safety barrier IS addressable 24 V 901324
classes in accordance with EN 54-5, along with
KMX5000 AP Ex communication module 912086
rate-of-rise and static responses. Setting via DIP
Silicone-free design
switches on the detector or SMX5000 service device
• Service interface, history memory
• Connection of remote indicator possible Not included in delivery
• For use in Ex zones 0, 1, 20, 21 and 22, Base UniVario MX5000 ST 916173
ATEX category 1, 2, 3 Gas/1, 2, 3 Dust Mounting bracket MX5000 ST 914914
Terminating resistor 1.8 K / 0.5 W 675235

Connection / mounting
Technical specifications Connection cable standard detector  2-wire
Detection method NTC sensor Additional fault line connection 2-wire
Remote indication  2-wire
Response classes A1, A2, B, C, indices S, R
Recommended cable JE-Y(St)Y 2x2x0.8 mm (0.03 inch), blue Ex
0 °C to +90 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Response temperatures
(+32 °F to +194 °F)
Operating voltage 7.6 V - 28 V DC
Approvals / marking
Quiescent current approx. 2.8 mA Ex conformity in acc. with 94/9/EG:
Alarm current consumption x II 1G Ex ia IIC T6/T4 Ga
approx. 15 mA
(without quiescent current) x II 1D Ex ia IIIC T95°C Da
The contents of this publication are subject to modifications without notice. All rights reserved.

Alarm indication 1 red LED Type examination certificate: BVS 12 ATEX E 121
Normal operation indication 1 green LED, flashing IECEx conformity: IECEx BVS 12.0074
Current indication
approx. 15 mA
Fault indication G 207090 0786-CPR-20280
Fault indication 1 yellow LED (2nd line)
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Stainless steel (saltwater-proof)
Relative humidity 0 to 95%
312-120_005 / AI00_2016en

(IEC 721-3-3) no condensation


Specification according to EN 54 Part 5
Weight approx. 1000 g (2.2 lbs)
130 x 84 mm (dia. x H)
Dimensions
5.1 x 3.3 inch (dia. x H)
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 24
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 3GD single hole Part no.: 907269


The single hole mounted WMX5000 3GD heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They are specifically
suited for use in dryer and ventilation ducts for the detection
of fires with rapid rise in temperature, e.g.:
– Flammable liquids and gases
– Highly flammable plastics
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat sensor, Remote indicator  908499
resistant against impact and vibration Weather protection MX5000 complete 910134
• Freely configurable response temperatures KMX5000 AP communication module 905883
and classes in accordance with EN 54-5, along with Silicone-free design
rate-of-rise and static responses. Configuration via DIP
switches on the detector or SMX5000 service device Not included in delivery
• Service interface, history memory Base UniVario MX5000 Ex 912082
• Connection of remote indicator possible Single hole mounting fixture 800034
• For use in Ex zones 2 and 22, Single hole mounting tool 800388
ATEX category 3, Gas/Dust Terminating resistor 1.8 K / 0.5 W 675235

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Additional fault line connection 2-wire
Detection method NTC sensor Remote indication  2-wire
Response classes A1, A2, B, C, D, indices S, R Recommended cable JY (St) Y 2x2x0.8 mm (0.03 inch)
Line cross-section  max. 2.5 mm2 (AWG 13)
0 °C to +105 °C
Response temperatures
(+32 °F to +221 °F)
Operating voltage 7.6 V - 30 V DC Approvals / marking
Quiescent current approx. 0.15 mA Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4
Alarm current consumption
x II 3D Ex tD A22 IP 65 T110°C
approx. 15 mA Type examination certificate: BVS 07 ATEX E 156
(without quiescent current)
Ex conformity Russia in acc. with TP TC 012/2011:
Alarm indication 1 red LED 2Ex nAc IIC T4
The contents of this publication are subject to modifications without notice. All rights reserved.

Normal operation indication 1 green LED, flashing Ex tc IIIC T110°C IP 65


Fault indication current approx. 15 mA
Fault indication 1 yellow LED (2nd line) G 297090 0786-CPR-20280
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
312-120_003 / AI01_2016en

Weight 580 g (1.3 lbs)


130 x 133 mm (dia. x H)
Dimensions
5.1 x 5.2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 25
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 Ex single hole Part no.: 912118


The single hole mounted WMX5000 Ex heat detectors
are ATEX-approved for category 2, gas and 1, 2 dust, and
are suitable for use in Ex zones 1, 20 and 21. They are
specifically suited for use in dryer and ventilation ducts for the
detection of fires with rapid rise in temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP Ex communication module.

Product features Optional accessories


• Robust stainless steel heat sensor, Safety barrier IS conventional 9 V  904991
resistant against impact and vibration Safety barrier IS addressable 24 V 901324
• Freely configurable response temperatures KMX5000 AP Ex communication module 912086
and classes in accordance with EN 54-5, along with Silicone-free design
rate-of-rise and static responses. Configuration via DIP
switches on the detector or SMX5000 service device Not included in delivery
• Service interface, history memory Base UniVario MX5000 Ex 912082
• Connection of remote indicator possible Single hole mounting fixture 800034
• For use in Ex zones 1, 20 and 21, Single hole mounting tool 800388
ATEX category 2, Gas/ 1, 2 Dust Terminating resistor 1.8 K / 0.5 W 675235

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Additional fault line connection 2-wire
Detection method NTC sensor Remote indication  2-wire
Response classes A1, A2, B, C, D, indices S, R Recommended cable JE-Y (St) Y 2x2x0.8 mm (0.03 inch)
Line cross-section  max. 2.5 mm2 (AWG 13)
0 °C to +105 °C
Response temperatures
(+32 °F to +221 °F)
Operating voltage 7.6 V - 28 V DC Approvals / marking
Quiescent current approx. 3.0 mA Ex conformity in acc. with 94/9/EG:
x II 2G Ex ia IIC T6/T4 Gb
Alarm current consumption
approx. 15 mA x II 1D Ex ia IIIC T95°C Da
(without quiescent current)
Type examination certificate: BVS 12 ATEX E121
Alarm indication 1 red LED IECEx conformity: IECEx BVS 12.0074
The contents of this publication are subject to modifications without notice. All rights reserved.

Normal operation indication 1 green LED, flashing Ex conformity Russia in acc. with TP TC 012/2011:
Fault indication current approx. 15 mA 1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Fault indication 1 yellow LED (2nd line) Ex ia IIIC T95°C Da
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F) G 207090 0786-CPR-20280
IP rating (EN 60529) IP 67
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
312-120_004 / AI01_2016en

Weight 580 g (1.3 lbs)


130 x 133 mm (dia. x H)
Dimensions
5.1 x 5.2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 26
Product Sheet | Detecon

Industrial detectors
UniVario Heat detectors, Ex standard

WMX5000 Ex ST single hole NEW Part no.: 916172


The single hole mounted WMX5000 Ex ST heat detectors
are ATEX and IECEx approved for category 1, 2, 3 Gas and
1, 2, 3 Dust, and are suitable for use in Ex zones 0, 1, 20,
21 and 22. They are specifically suited for use in dryer and
ventilation ducts for the detection of fires with rapid rise in
temperature, e.g.:
- Flammable liquids and gases
- Highly flammable plastics
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection.
The detectors must be connected via a safety barrier.
Designed for use in tough industrial environments and
Product features Off-shore applications. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
• Stainless steel version V4A
protocol via the KMX5000 AP Ex communication module.
• Robust stainless steel heat sensor,
resistant against impact and vibration
• Freely configurable response temperatures Optional accessories
and classes in accordance with EN 54-5, along with Safety barrier IS conventional 9 V  904991
rate-of-rise and static responses. Configuration via DIP Safety barrier IS addressable 24 V 901324
switches on the detector or SMX5000 service device KMX5000 AP Ex communication module 912086
• Service interface, history memory Silicone-free design
• Connection of remote indicator possible
• For use in Ex zones 0, 1, 20, 21 and 22, Not included in delivery
ATEX category 1, 2, 3 Gas/1, 2, 3 Dust Base UniVario MX5000 ST 916173
Single hole mounting fixture 800034
Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235
Technical specifications
Detection method NTC sensor
Connection / mounting
Response classes A1, A2, B, C, D, indices S, R
Connection cable standard detector  2-wire
0 °C to +105 °C Additional fault line connection 2-wire
Response temperatures
(+32 °F to +221 °F) Remote indication  2-wire
Operating voltage 7.6 V - 28 V DC Recommended cable JE-Y(St)Y 2x2x0.8 mm (0.03 inch), blue Ex
Line cross-section  max. 2.5 mm2 (AWG 13)
Quiescent current approx. 3.0 mA
Alarm current consumption
approx. 15 mA Approvals / marking
(without quiescent current)
Ex conformity in acc. with 94/9/EG:
The contents of this publication are subject to modifications without notice. All rights reserved.

Alarm indication 1 red LED


x II 1G Ex ia IIC T6/T4 Ga
Normal operation indication 1 green LED, flashing
x II 1D Ex ia IIIC T95°C Da
Fault indication current approx. 15 mA Type examination certificate: BVS 12 ATEX E121
Fault indication 1 yellow LED (2nd line) IECEx conformity: IECEx BVS 12.0074
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F) G 207090 0786-CPR-20280
IP rating (EN 60529) IP 67
Enclosure material Stainless steel (saltwater-proof)
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
312-120_006 / AI00_2016en

Specification according to EN 54 Part 5


Weight approx. 1000 g (2.2 lbs)
130 x 133 mm (dia. x H)
Dimensions
5.1 x 5.2 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 27
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS, Ex

WMX5000 FS 3GD 400°C (752 °F) Part no.: 907270


The WMX5000 FS 3GD high temperature heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They have been
specially designed for operation in industrial environments with
aggressive media and very high application temperatures in
the monitoring area.
For example in exhaust ducts, engine test stands or machine
tools. In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP communication module.

Product features Optional accessories


• Robust stainless steel heat rod sensor Remote indicator  908499
• Freely configurable response temperatures and KMX5000 AP communication module 905883
classes in accordance with EN 54-5, along with Silicone-free design
rate-of-rise and static responses. Configuration via DIP
switches on the detector or SMX5000 service device Not included in delivery
• Service interface, history memory Base UniVario MX5000 Ex 912082
• Connection of remote indicator possible Single hole mounting fixture 800034
• For use in Ex zones 2 and 22, Atex category 3, Gas/Dust Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235

Technical specifications Connection / mounting


Connection cable standard detector 2-wire
Detection method PT1000 sensor Additional fault line connection 2-wire
A1, A2, B, C, D, E, F, G, Remote indication  2-wire
Response classes
indices S, R Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
0 °C to +400 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Response temperatures
(+32 °F to +752 °F)
Operating voltage 7.6 V - 30 V DC Note
Quiescent current approx. 0.25 mA The desired length of the sensor rod must be specified in
millimetres at the time of placing the order. Alternatively,
Alarm current consumption approx. 15 mA
fixed standard rod lengths are available to choose from.
Alarm indication 1 red LED
Normal operation indication 1 green LED, flashing Approvals / marking
Fault indication current approx. 15 mA Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication 1 yellow LED (2nd line) x II 3D Ex tD A22 IP 65 T110°C


-20 °C to +80 °C Type examination certificate: BVS 07 ATEX E 157
Operating temperature Ex conformity Russia in acc. with TP TC 012/2011:
(-4 °F to +176 °F)
2Ex nAc IIC T4
IP rating (EN 60529) IP 67
Ex tc IIIC T110°C IP 65
Enclosure material Diecast aluminium
Relative humidity 0 to 95%
(IEC 721-3-3) no condensation G 207091 0786-CPR-20281
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
312-140_001 / AI01_2016en

130 x 150 to 1500 mm (dia. x H)


Dimensions
5.1 x 5.9 to 59.1 inch (dia. x H)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 28
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS, Ex

WMX5000 FS 3GD 400 °C 200 mm Part no.: 907281


(752 °F 7.9 inch)
With fixed rod length of 200 mm (7.9 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 907270
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x 260 mm (dia. x H)
Dimensions
5.1 x 10.2 inch (dia. x H)

WMX5000 FS 3GD 400 °C 400 mm Part no.: 907282


(752 °F 15.8 inch)
With fixed rod length of 400 mm (15.8 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 907270
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x 460 mm (dia. x H)
Dimensions
5.1 x 18.1 inch (dia. x H)

WMX5000 FS 3GD 400 °C 600 mm Part no.: 907283


The contents of this publication are subject to modifications without notice. All rights reserved.

(752 °F 23.6 inch)


With fixed rod length of 600 mm (23.6 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 907270
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
Dimensions
5.1 x 26 inch (dia. x H)
312-140_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 29
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS, Ex

WMX5000 FS Ex 400°C Part no.: 912108

The WMX5000 FS Ex high temperature heat detectors


are ATEX- and IEC approved for category 2 gas and
1, 2 dust, and are suitable for use in Ex zones 1, 20 and 21.
They have been specially designed for operation in
industrial environments with aggressive media and very
high application temperatures in the monitoring area.
For example in exhaust ducts, engine test stands or machine
tools. In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Equipped for operation as a
conventional detector. Extension to a detector with Loop AP
protocol via the KMX5000 AP Ex communication module.

Product features Optional accessories


• Robust stainless steel heat rod sensor Safety barrier IS conventional 9 V  904991
• Freely configurable response temperatures and Safety barrier IS addressable 24 V 901324
classes in accordance with EN 54-5, along with KMX5000 AP Ex communication module 912086
rate-of-rise and static responses. Configuration via DIP Weather protection MX5000 complete  910134
switches on the detector or SMX5000 service device Silicone-free design
• Service interface, history memory
• Connection of remote indicator possible Not included in delivery
• For use in Ex zones 1, 20 and 21, Base UniVario MX5000 Ex 912082
Atex category 3 Gas/1, 2 Dust Single hole mounting fixture 800034
Single hole mounting tool 800388
Terminating resistor 1.8 K / 0.5 W 675235

Technical specifications Connection / mounting


Detection method PT1000 sensor Connection cable standard detector 2-wire
A1, A2, B, C, D, E, F, G,
Additional fault line connection 2-wire
Response classes Remote indication  2-wire
indices S, R
Recommended cable  JE-Y (St) Y 2x2x0.8 mm (0.03 inch)
0 °C to +400 °C
Response temperatures Conductor cross-section max. 2.5 mm2 (AWG 13)
(+32 °F to +752 °F)
Operating voltage 7.6 V - 28 V DC
Note
Quiescent current approx. 2.8 mA
The desired length of the sensor rod must be specified in
Alarm current consumption approx. 15 mA millimetres at the time of placing the order. Alternatively,
Alarm indication 1 red LED fixed standard rod lengths are available to choose from.
Normal operation indication 1 green LED, flashing
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA Approvals / marking


Ex conformity in acc. with 94/9/EC:
Fault indication 1 yellow LED (2nd line)
x II 2G Ex ia IIC T6/T4 Gb
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
x II 1D Ex ia IIIC T95°C Da
Type examination certificate: BVS 12 ATEX E120
IP rating (EN 60529) IP 67 IECEx conformity: IECEx BVS 12.0073
Enclosure material Diecast aluminium Ex conformity Russia in acc. with TP TC 012/2011:
Relative humidity 0 to 95%
1Ex ia IIC T6/T4 Gb
(IEC 721-3-3) no condensation 0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
Specification according to EN 54 Part 5
Weight 520 to 1600 g (1.2 to 3.5 lbs)
312-140_001 / AI01_2016en

G 207091 0786-CPR-20281
130 x 150 to 1500 mm (dia. x H)
Dimensions
5.1 x 5.9 to 59.1 inch (dia. x H)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 30
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS, Ex

WMX5000 FS Ex 400 °C 200 mm Part no.: 912110


(752 °F 7.9 inch)
With fixed rod length of 200 mm (7.9 inch)

Technical specifications
Otherwise like part no.: 912108
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x 260 mm (dia. x H)
Dimensions
5.1 x 10.2 inch (dia. x H)

WMX5000 FS Ex 400 °C 400 mm Part no.: 912111


(752 °F 15.8 inch)
With fixed rod length of 400 mm (15.8 inch)

Technical specifications
0 °C to +400 °C
Otherwise like part no.: 912108
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x 460 mm (dia. x H)
Dimensions
5.1 x 18.1 inch (dia. x H)

WMX5000 FS Ex 400 °C 600 mm Part no.: 912112


The contents of this publication are subject to modifications without notice. All rights reserved.

(752 °F 23.6 inch)


With fixed rod length of 600 mm (23.6 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 912108
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
Dimensions
5.1 x 26 inch (dia. x H)
312-140_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 31
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS, Ex

WMX5000 FS Ex ST NEW Part no.: 916179

The WMX5000 FS Ex ST high temperature heat detectors


are ATEX- and IECEx approved for category 1, 2, 3 Gas and
1, 2, 3 Dust, and are suitable for use in Ex zones 0, 1, 20, 21
and 22. The detectors must be connected via a safety barrier.
They have been specially designed for use in tough industrial
environments with aggressive media up to
Off-shore applications and very high application temperatures
in the monitoring area. In addition to stated temperature
detection, rapid rises in temperature can also be registered
by the rate-of-rise method, for early fire detection. Equipped
for operation as a conventional detector. Extension to a
detector with Loop AP protocol via the KMX5000 AP Ex
communication module.
Product features
• Stainless steel version V4A Optional accessories
• Robust stainless steel heat rod sensor Safety barrier IS conventional 9 V  904991
Safety barrier IS addressable 24 V 901324
• Freely configurable response temperatures and
KMX5000 AP Ex communication module 912086
classes in accordance with EN 54-5, along with
Silicone-free design
rate-of-rise and static responses. Configuration via DIP
switches on the detector or SMX5000 service device
• Service interface, history memory Not included in delivery
• Connection of remote indicator possible Base UniVario MX5000 Ex ST 916173
Single hole mounting fixture 800034
• For use in Ex zones 0, 1, 20, 21 and 22,
Single hole mounting tool 800388
ATEX category 1, 2, 3 Gas/1, 2, 3 Dust
Terminating resistor 1.8 K / 0.5 W 675235

Connection / mounting
Technical specifications Connection cable standard detector  2-wire
Detection method PT1000 sensor Additional fault line connection 2-wire
Remote indication  2-wire
A1, A2, B, C, D, E, F, G,
Response classes
indices S, R
Recommended cable JE-Y(St)Y 2x2x0.8 mm (0.03 inch), blue Ex
Conductor cross-section  max. 2.5 mm2 (AWG 13)
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Operating voltage 7.6 V - 28 V DC
Note
The desired length of the sensor rod must be specified in
Quiescent current approx. 2.8 mA
millimetres at the time of placing the order.
Alarm current consumption approx. 15 mA
Alarm indication 1 red LED Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

Normal operation indication 1 green LED, flashing Ex conformity in acc. with 94/9/EC:
Current consumption x II 1G Ex ia IIC T6/T4 Ga
approx. 15 mA
Fault indication x II 1D Ex ia IIIC T95°C Da
Fault indication 1 yellow LED (2nd line) Type examination certificate: BVS 12 ATEX E 120
IECEx conformity: IECEx BVS 12.0073
-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 67 G 207091 0786-CPR-20281

Enclosure material Stainless steel (saltwater-proof)


Relative humidity 0 to 95%
(IEC 721-3-3) no condensation
312-140_003 / AI00_2016en

Specification according to EN 54 Part 5


Weight approx. 1 to 2.1 kg (2.2 to 4.6 lbs)
130 x 150 to 1500 mm (dia. x H)
Dimensions
5.1 x 5.9 to 59.1 inch (dia. x H)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 32
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex, Ex

WMX5000 FS Flex 3GD 400°C (752 °F) Part no.: 907284


The WMX5000 FS 3GD high temperature heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They have been
specially designed for operation in industrial environments
with aggressive media and very high application
temperatures in the monitoring area. For example in exhaust
ducts, engine test stands or machine tools. In addition to
stated temperature detection, rapid rises in temperature can
also be registered by the rate-of-rise method, for early fire
detection. Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via the
KMX5000 AP communications module.

Product features Optional accessories


• Robust flexible stainless steel heat sensor Remote indicator  908499
KMX5000 AP communication module 905883
• Freely configurable response temperatures and
Silicone-free design
classes in accordance with EN 54-5, along with
rate-of-rise and static responses. Configuration via DIP
switches on the detector or SMX5000 service device Not included in delivery
• Service interface, history memory Base UniVario MX5000 Ex 912082
Holder WMX FS, from
• Connection of remote indicator possible 250 °C (482 °F) to 600 °C (1112 °F) 894679
• For use in Ex zones 2 and 22, Atex category 3, Gas/Dust Terminating resistor 1.8 K / 0.5 W  675235

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Additional fault line connection 2-wire
Detection method PT1000 sensor Remote indication  2-wire
A1, A2, B, C, D, E, F, G, Recommended cable  JY (St) Y 2x2x0.8 mm (0.03 inch)
Response classes
indices S, R Conductor cross-section max. 2.5 mm2 (AWG 13)
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Note
Operating voltage 7.6 V - 30 V DC The desired length of the flexible sensor must be
Quiescent current approx. 0.25 mA specified in metres at the time of placing the order.
Alarm current consumption approx. 15 mA
The sensor rod holder is designed for operation temperatures
of up to 250 °C (482 °F). For higher operation temperatures,
Alarm indication 1 red LED the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F)
Normal operation indication 1 green LED, flashing Part no. 894679 is to be used.
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA


Fault indication 1 yellow LED (2nd line) Approvals / marking
-20 °C to +80 °C Ex conformity in acc. with 94/9/EC: x II 3G Ex nA II T4
Operating temperature
(-4 °F to +176 °F) x II 3D Ex tD A22 IP 65 T110°C
IP rating (EN 60529) IP 67 Type examination certificate: BVS 07 ATEX E 157
Ex conformity Russia in acc. with TP TC 012/2011:
Enclosure material Diecast aluminium 2Ex nAc IIC T4
Relative humidity 0 to 95% Ex tc IIIC T110°C IP 65
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 5
G 207091 0786-CPR-20281
Weight 520 to 1600 g (1.2 to7.5 lbs)
312-160_001 / AI01_2016en

130 x 2000 to 9000 mm (dia. x H)


Dimensions
5.1 x 78.7 x 354.3 inch (dia. x H)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 33
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex, Ex

WMX5000 FS Flex 3GD 400 °C 2 m Part no.: 907285


(752 °F 79 inch)
Version with flexible hose of 2 m length (79 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 907284
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
Dimensions
5.1 x up to 78.73 inch (dia. x H)

WMX5000 FS Flex 3GD 400 °C 6 m Part no.: 907286


(752 °F 236 inch)
Version with flexible hose of 6 m length (236 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 907284
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
Dimensions
5.1 x up to 236.2 inch (dia. x H)

WMX5000 FS Flex 3GD 400 °C 9 m Part no.: 907287


The contents of this publication are subject to modifications without notice. All rights reserved.

(752 °F 354 inch)


Version with flexible hose of 9 m length (354 inch)

Technical specifications
Otherwise like part no.: 907284
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
Dimensions
5.1 x up to 354.3 inch (dia. x H)
312-160_001 / AI01_2016en

WMX5000 FS Flex 3GD 400 °C Part no.: 909387


(752 °F) CN Approvals / marking
Version China

Otherwise like part no.: 907284


2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 34
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex, Ex

WMX5000 FS Flex Ex 400°C Part no.: 912113


The WMX5000 FS Ex high temperature heat detectors
are ATEX and IEC approved for category 2 gas and
1, 2 dust, and are suitable for use in Ex zones 1, 20 and 21.
They have been specially designed for operation in
industrial environments with aggressive media and very
high application temperatures in the monitoring area.
For example in exhaust ducts, engine test stands or machine
tools. In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early fire detection. Designed for operation as a
conventional detector. Expansion to a detector with Loop AP
protocol via the KMX5000 AP Ex communications module.

Product features Optional accessories


• Robust flexible stainless steel heat sensor Safety barrier IS conventional 9 V  904991
Safety barrier IS addressable 24 V 901324
• Freely configurable response temperatures and
KMX5000 AP Ex communication module 912086
classes in accordance with EN 54-5, along with
Weather protection MX5000 complete  910134
rate-of-rise and static responses. Configuration via DIP
Silicone-free design
switches on the detector or SMX5000 service device
• Service interface, history memory Not included in delivery
• For use in Ex zones 1, 20 and 21, Base UniVario MX5000 Ex 912082
Atex category 2, Gas/1,2 Dust Holder WMX FS, from
250 °C (482 °F) to 600 °C (1112 °F) 894679
Terminating resistor 1.8 K / 0.5 W  675235

Technical specifications Connection / mounting


Detection method PT1000 sensor Connection cable standard detector 2-wire
Additional fault line connection 2-wire
A1, A2, B, C, D, E, F, G,
Response classes Remote indication  2-wire
indices S, R
Recommended cable  JE-Y (St) Y 2x2x0.8 mm (0.03 inch)
0 °C to +400 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Response temperatures
(+32 °F to +752 °F)
Operating voltage 7.6 V - 28 V DC Note
Quiescent current approx. 2.8 mA The desired length of the flexible sensor must be
Alarm current consumption approx. 15 mA specified in metres at the time of placing the order.
The sensor rod holder is designed for operation temperatures
Alarm indication 1 red LED of up to 250 °C (482 °F). For higher operation temperatures,
Normal operation indication 1 green LED, flashing the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F)
Part no. 894679 is to be used.
The contents of this publication are subject to modifications without notice. All rights reserved.

Fault indication current approx. 15 mA


Fault indication 1 yellow LED (2nd line)
Approvals / marking
-25 °C to +80 °C Ex conformity in acc. with 94/9/EG:
Operating temperature
(-13 °F to +176 °F)
x II 2G Ex ia IIC T6/T4 Gb
IP rating (EN 60529) IP 67 x II 1D Ex ia IIIC T95°C Da
Enclosure material Diecast aluminium Type examination certificate: BVS 12 ATEX E120
Relative humidity 0 to 95% IECEx conformity: IECEx BVS 12.0073
(IEC 721-3-3) no condensation Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Specification according to EN 54 Part 5
0Ex ia IIC T6/T4 Ga
Weight 520 to 1600 g (1.2 to7.5 lbs) Ex ia IIIC T95°C Da
312-160_002 / AI01_2016en

130 x 2000 to 9000 mm (dia. x H)


Dimensions
5.1 x 78.7 x 354.3 inch (dia. x H) 0786-CPR-20281
G 207091

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 35
Product Sheet | Detecon

Industrial detectors
UniVario High temperature heat detector FS Flex, Ex

WMX5000 FS Flex Ex 400 °C 2 m Part no.: 912114


(752 °F 79 inch)
Version with flexible hose of 2 m length (79 inch)

Technical specifications
Otherwise like part no.: 912113
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Weight 680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
Dimensions
5.1 x up to 78.73 inch (dia. x H)

WMX5000 FS Flex Ex 400 °C 6 m Part no.: 912115


(752 °F 236 inch)
Version with flexible hose of 6 m length (236 inch)

Technical specifications
Otherwise like part no.: 912113
0 °C to +400 °C
Response temperatures
(+32 °F to +752 °F)
Weight 840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
Dimensions
5.1 x up to 236.2 inch (dia. x H)

WMX5000 FS Flex Ex 400 °C 9 m Part no.: 912116


The contents of this publication are subject to modifications without notice. All rights reserved.

(752 °F 354 inch)


Version with flexible hose of 9 m length (354 inch)

Technical specifications
0 °C to +400 °C Otherwise like part no.: 912113
Response temperatures
(+32 °F to +752 °F)
Weight 1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
Dimensions
5.1 x up to 354.3 inch (dia. x H)
312-160_002 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 36
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

KMX5000 AP communication module Part no.: 905883

Communication module for the operation of UniVario


detectors on fire alarm panels with Loop AP protocol.
By simply plugging the module into the detector, a
conventional detector is turned into an analogue
addressable detector. The detector address is set
via a DIP switch. Power supply and communications
are connected via the ring bus; no additional power supply
is required. The KMX5000 AP communication module is
designed for integration into UniVario series detectors
and must not be used in hazard areas.

Product features Included in delivery


• Communication module for constant 1 KMX5000 AP communication module
signalling of operating condition, alarms Pan-head screw and Spacer
and faults via Loop AP protocol
• Ring bus connection, no additional power supply Connection / mounting
• Integration in UniVario series detectors Plug-in module in UniVario series detectors

Approvals / marking
Technical specifications
G 207032 0786-CPR-20315
10 spring contacts
Connection
(module/detector)
Operating voltage 17 V - 28 V DC
Operating current approx. 0,3 mA
Communication protocol Loop AP
Addressing 8 position DIP switch
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Relative humidity 5 to 85%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 18
Weight 15 g (0.03 lbs)
54 x 28 x 19.5 mm (LxWxH)
Dimensions
2.1 x 1.1 x 0.8 inch (LxWxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 37
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

KMX5000 AP Ex communication module Part no.: 912086


Communication module for the operation of UniVario
detectors on fire alarm panels with Loop AP protocol.
By simply plugging the module into the detector,
a conventional detector is turned into an analogue
addressable detector. The detector address is set
via a DIP switch. Power supply and communications are
connected via the ring bus; no additional power supply is
required. The KMX5000 AP Ex communication module is
designed for integration into UniVario series detectors and
may be used in hazard areas.

Product features Included in delivery


• Communication module for constant 1 KMX5000 AP Ex communication module
signalling of operating condition, alarms Pan-head screw and Spacer
and faults via Loop AP protocol
• Ring bus connection, no additional power supply Connection / mounting
• Integration in UniVario Ex series detectors Plug-in module in UniVario Ex series detectors

Approvals / marking
Technical specifications Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T5/T4 Gb
10 spring contacts
Connection
(module/detector)
Operating voltage 14 V - 22 V DC G 207032 0786-CPR-20315

Operating current approx. 0,3 mA


Communication protocol Loop AP
Addressing 8 position DIP switch
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Relative humidity 5 to 85%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 18
Weight 15 g (0.03 lbs)
54 x 28 x 19.5 mm (LxWxH)
Dimensions
2.1 x 1.1 x 0.8 inch (LxWxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_002 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 38
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Relay module KMX5000 RK Part no.: 906361


Communication module for the operation of UniVario
detectors, independent of any fire detection system.
Dry contacts for alarm and fault signalling allow the detectors
to be used as stand-alone units, in any fire and hazard
detection system or in building management and control
systems. The KMX5000 RK communication module is
designed to be integrated into the UniVario detector base
MX5000 and must not be used in hazardous areas.

Product features Included in delivery


• Dry changeover contacts for alarm and fault signalling Relay module KMX5000 RK
• Integration into MX5000 detector base Jumper
Installation material

Connection / mounting
Technical specifications
Conductor cross-section  min. 0.5 mm2 (AWG 20)
Connection 6-conductor ribbon cable max. 2.5 mm2 (AWG 13)
Operating voltage 24 V (14 V - 29 V) DC
Quiescent current approx. 7 mA Approvals / marking
Current consumption with
approx. 20 mA
alarm relay active G 208058 0786-CPD-20314
Current consumption with
alarm relay and fault relay approx. 30 mA
active
Voltage load, contacts max. 60 V DC, 25 V AC
Current load, contacts max. 1 A
Fault indication 1 yellow LED (2nd line)
-20 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
Relative humidity 5 to 85%
(IEC 721-3-3) no condensation
Specification according to EN 54 Part 18
Weight
The contents of this publication are subject to modifications without notice. All rights reserved.

50 g (0.1 lbs)
64 x 24 x 57 mm (LxWxH)
Dimensions
2.5 x 0.9 x 2.2 inch (LxWxH)
312-810_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 39
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Base MX5000 Part no.: 904701


Retaining base for all UniVario industrial fire detectors.
Contains cable entries, EMC and environmental seals,
connecting terminals and space for the optional relay
module KMX5000 RK. Enables replacement of a detector
without any terminal work.

Not included in delivery


End of line resistor 1.8 K / 0.5 W 675235

Spare parts
Seal 127 x 2.9 / 1.6 mm 904752
Gland M 16 x 1.5 Ms 901861
Sealing cord 8 mm Vitron 0.036 m 800605
Technical specifications
Material Aluminium Approvals / marking
Relative humidity max. 100 %
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour red
-40 °C to +100 °C
Ambient temperature
(-40 °F to +212 °F)
Weight 310 g (0.7 lbs)

Base MX5000 SF Part no.: 914235


Silicon free base Otherwise like part no. 904701

Base MX5000 3M16 Part no.: 907011


Retaining base for all UniVario industrial fire detectors.
Contains cable entries, EMC and environmental seals,
connecting terminals and space for the optional relay module
KMX5000 RK. The third cable gland allows the interface
connection with detector remote indicators or similar devices.

Not included in delivery


End of line resistor 1.8 K / 0.5 W 675235
The contents of this publication are subject to modifications without notice. All rights reserved.

Spare parts
Seal 127 x 2.9 / 1.6 mm 904752
Gland M 16 x 1.5 Ms 901861
Technical specifications Sealing cord 8 mm Vitron 0.036 m 800605
Material Aluminium
Relative humidity max. 100 % Approvals / marking
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour red
312-810_001 / AI00_2015en

-40 °C to +100 °C
Ambient temperature
(-40 °F to +212 °F)
Weight 350 g (0.8 lbs)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 40
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Base MX5000 LCD Part no.: 906127


Base for displaying status and signal messages
from industrial fire alarms of the UniVario series.
The LCD display gives information about sensor
temperature, alarms or other operating states, depending
on the detector type. Includes cable entries, EMC and
environmental seals and connecting terminals. Enables
replacement of a detector without any terminal work.
The LCD base must not be used in hazard areas.

Not included in delivery


End of line resistor 1.8 K / 0.5 W 675235

Spare parts
Technical specifications Seal 127 x 2.9 / 1.6 mm 904752
Gland M 16 x 1.5 Ms 901861
Operating voltage by means of the detector
Sealing cord 8 mm Vitron 0.036 m 800605
Operating current 0.3 mA
Material Aluminium Approvals / marking
Relative humidity max. 100 %
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour red
-20 °C to +70 °C
Ambient temperature
(-4 °F to +158 °F)
Weight 350 g (0.8 lbs)

Base MX5000-I Part no.: 912493

Detector base for installation of the UniVario industrial fire


detectors in the LoopAP ringbus. Contains cable glands,
EMC and environmental sealing as well as terminals.
Not suitable for use in hazardous explosive areas.
The installed dual isolator increases the operational safety
of the LoopAP ringbus in the event of a short-circuit.

Spare parts
Seal 127 x 2.9 / 1.6 mm 904752
The contents of this publication are subject to modifications without notice. All rights reserved.

Gland M 16 x 1.5 Ms Ex 904652


Sealing cord 8 mm Vitron 0.036 m 800605

Approvals / marking
Technical specifications
Material Aluminium
Relative humidity max. 100 %
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour red
-20 °C to +80 °C
312-810_001 / AI00_2015en

Ambient temperature
(-4 °F to +176 °F)
Weight 530 g (1.2 lbs)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 41
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Base MX5000 Ex Part no.: 912082


Detector base for installation of the UniVario industrial fire de-
tectors of the 3GD and Ex series. Contains cable inlets, EMC
and environmental sealing as well as terminals. In this way,
detectors can be replaced without requiring connecting work.

Not included in delivery


End of line resistor 1.8 K / 0.5 W 675235

Spare parts
Seal 127 x 2.9 / 1.6 mm 904752
Gland M 16 x 1.5 Ms Ex 904652
Sealing cord 8 mm Vitron 0.036 m 800605

Technical specifications
Approvals / marking
Material Aluminium Ex conformity Russia in acc. with TP TC 012/2011:
Relative humidity max. 100 % 1Ex ib IIC T5/T4 Gb
Conductor cross-section max. 2.5 mm2 (AWG 13)
Colour red
-40 °C to +100 °C
Ambient temperature
(-40 °F to +212 °F)
Weight 530 g (1.2 lbs)

Bracket MX5000 Part no.: 904757


Mounting bracket for UniVario MX5000 base

Included in delivery
1 Bracket UniVario MX5000
2 Screws M8, hex socket size 5 mm (0.2 inch)

Not included in delivery


Mounting screws for wall/ceiling-mounted installation.

Spare parts
Technical specifications Screw M 8  904355
The contents of this publication are subject to modifications without notice. All rights reserved.

Stainless steel, 2 mm
Material
(0.08 inch) thick
Bracket retention Plastic (POM), black
Weight 110 g (0.2 lbs)

Bracket MX5000 SF Part no.: 914234


Silicon free bracket Otherwise like part no. 904757
312-810_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 42
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Base MX5000 ST Part no.: 916173

Detector base for installation of the UniVario industrial


fire detectors of the ST (stainless steel) series. Contains
cable inlets, EMC and environmental sealing as well as
terminals. In this way, detectors can be replaced without
requiring connecting work.

Included in delivery
2 Gland M20 x 1,5 Ex-d A4  920793

Not included in delivery


End of line resistor 1.8 K / 0.5 W 675235

Technical specifications
Material Stainless steel (saltwater-proof)
Relative humidity max. 100 %
Conductor cross-section max. 2.5 mm2 (AWG 13)
-25 °C to +80 °C
Ambient temperature
(-13 °F to +176 °F)
Weight 800 g (1.7 lbs

Mounting bracket MX5000 ST Part no.: 914914


Mounting bracket for Base UniVario MX5000 ST

Included in delivery
1 Mounting bracket MX5000
2 Screw M8 hex socket size 5 mm (0.2 inch)

Not included in delivery


Mounting screws for wall/ceiling-mounted installation

Spare parts
Screw M8 x 12 St 917707
Technical specifications
The contents of this publication are subject to modifications without notice. All rights reserved.

Material Stainless steel (saltwater-proof)


Weight 4.25 kg (9.4 lbs)
312-810_006 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 43
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Isolator ISX 284 3GD Part no.: 915864

Isolator XP and DIS for the separation of individual line


sections in the event of short circuits in ringbus operation
with approval for ATEX category 3 gas and dust.
Are suitable for use in Ex zones 2 and 22.

Approvals / marking
Technical specifications
Ex conformity in acc. with 94/9/EG:
Material Aluminium x II 2G Ex d IIB T6 Gb
Fault indication inside yellow LED x II 2D Ex tb IIIC T80°C Db
IP rating (EN 60529) IP 66 EC type approval certificate: BVS 11 ATEX E114
Colour grey
-20 °C to +60 °C
Ambient temperature
(-4 °F to +140 °F)
1.2 kg
Weight
(2.6 lbs)
90 mm (dia.)
Dimensions
3.5 inch (dia.)

Air shield MX5000 Part no.: 914322


The air shield is only intended for use with UniVario flame
detectors. It is used to prevent contamination of the optic
and reflector of the detector. Only use in dry dusty or
powder-containing environments.

Note
Image shows air shield complete mounted to detector
The contents of this publication are subject to modifications without notice. All rights reserved.

Included in delivery
Air shield with gland G1/4“-6 (6 mm hose), without detector

Not included in delivery


Technical specifications Hose 6x4 PUN  914329
Hose 6x4 PUN ANTISTAT (Ex) 919559
Material Aluminium
optional:
Compressed air operation min. 0.01 MPa (1.5 psi)
Gland G1/4“-8 (8 mm hose) 918670
Flow rate min. 1 m3/h (35 ft3/h) Hose 8x6 PA FL 845956
Hose connection 6 mm (0.24 inch) Hose 8x6 PUN ANTISTAT (Ex) 919560
Weight 0.47 kg (1.0 lbs)
312-810_007 / AI01_2016en

Approvals / marking

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 44
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Air shield MX5000 pulse Part no.: 919551


The air shield pulse is only intended for use with UniVario
flame detectors. In combination with the pulse air purging
unit the air shield pulse is preventing contamination on the
lens and the reflector of the detector. Only use in dry dusty
or powder-containing environments. By the pulse mode, the
energy costs are significantly reduced.

Included in delivery
Air shield pulse with gland G1/4“-8 (8 mm hose), without
detector

Not included in delivery


Technical specifications Pulse air purging unit 919510
Material Aluminium Hose 8x6 PA FL 845956
Hose 8x6 PUN ANTISTAT (Ex) 919560
0.1 MPa to 0.5 MPa
Compressed air operation
(14.5 psi to 72.5 psi) optional:
Flow rate depending setting Gland G1/4“-6 (6 mm hose) 918669
Hose 6x4 PUN  914329
Hose connection 8 mm (0.31 inch)
Hose 6x4 PUN ANTISTAT (Ex) 919559
Weight 0.47 kg (1.0 lbs)

Approvals / marking
Note
Image presentation air shield complete mounted to detector

Pulse air purging unit Part no.: 919510


The pulse purging unit is used for optical flame and spark
detectors. The unit supplies air purging attachments with
compressed air. The unit ensures short compressed air blasts
by a time-controlled magnetic valve. The cleaning effect of
the air purging attachment is increased. The consumption
of compressed air is decreased. Only dry dust and powdery
soiling can be removed effectively.

Not included in delivery


Compressed air inlet:
Technical specifications Fitting IQSG-G1/2“-8 (8 mm hose) 919554
The contents of this publication are subject to modifications without notice. All rights reserved.

Coupling connector NW7,2 G1/2“ 919555


Material Aluminium
Hose 8x6 PA FL 845956
min. 0.5 MPa, max. 1.0 MPa Hose 8x6 PUN ANTISTAT (Ex) 919560
Compressed air at the inlet
(5 bar to 10 bar)
min. 0.1 MPa, max. 0.5 MPa Compressed air outlet:
Compressed air at the outlet
(1 bar to 5 bar), adjustable Fitting IQSG-G1/2“-8 (8 mm hose) 919554
Purity classes of compressed Coupling connector IQSLV2-G1/2“-8 (8 mm hose) 919556
air Coupling connector IQSLV3-G1/2“-8 (8 mm hose) 919557
according to ISO 8573-1:
1-2 Coupling connector IQSLV4-G1/2“-8 (8 mm hose) 919558
Class oil aerosol content
4
Class humidity
1-2
Class solid particle content
Connectable air purging Approvals / marking
312-810_008 / AI01_2016en

max. 4
attachment
0 °C to +50 °C
Ambient temperature
(+32 °F to +122 °F)
Power supply 230 V AC, 10 W
Hose connection 8 mm (0.31 inch)
Weight 4.3 kg (9.5 lbs)
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 45
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Console MX5000 Flame detector Part no.: 904758


Console for the installation of UniVario flame detectors
outside of monitored areas, e.g. air ducts, machine tools,
containers or silos. Easy access to the detector. Bayonet
socket for reliable, vibration-proof hold. Antistatic material for
use in hazard areas up to zones 1 and 21.

Included in delivery
Mount with flat sealing and springs 906148
Screw M5  904341
Self-tapping screw 765233
Blind rivets  885078
O-ring 904759
Installation drawing 906970

Technical specifications
Material PA6 99/0701 EC
138 x 15 mm (WxH)
Dimensions
6.6 x 0.6 inch (WxH)
Colour black
-20 °C to +100 °C
Ambient temperature
(-4 °F to +212 °F)
Weight 145 g (0.3 lbs)

Console MX5000 Heat detector Part no.: 906969

Console for the installation of UniVario heat detectors


on e.g. air ducts, dryers or machine tools. Easy access
to the detector. Bayonet socket for reliable, vibration-proof
hold.Antistatic material for use in hazard areas up to zones
1 and 21.

Included in delivery
Console with flat sealing and springs 906148
Screw M5  904341
Self-tapping screw 765233
Blind rivets  885078
O-ring 904759
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Material PA6 99/07001 EC
138 x 16.2 mm (WxH)
Dimensions
5.4 x 0.6 inch (WxH)
Colour black
-20 °C to +100 °C
Ambient temperature
(-4 °F to +212 °F)
Weight 145 g (0.3 lbs)
312-810_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 46
Product Sheet | Detecon

Industrial detectors
UniVario Detector accessories

Weather protection MX5000 complete Part no.: 910134


Additional equipment – weather protection for flame
detectors of the Uni Vario series for use in case of increased
solar radiation or exposure to harsh weather conditions.

Connection / mounting
Fasten the weather protection to the detector

Technical specifications
Stainless steel, 0.5 mm
Material
(0.02 inch) thick
140 x 110 x 220 mm (WxHxL)
Dimensions
5.5 x 4.3 x 8.7 inch (WxHxL)
Colour internally black
Weight 300 g (0.67 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 47
Product Sheet | Detecon

Industrial detectors
UniVario Test equipment

Service device SMX5000 Part no.: 906136


The service device is for the simplified configuration,
diagnostics and function testing of the UniVario detectors,
and for indicating events from the history memory.
The SMX5000 can be used on UniVario detectors
with software version V01 Exx or higher.
An RS-232 interface can be used to transmit data from
the history memory to the UniVario View software.

Product features Included in delivery


• Display with 3 rows of 12 characters each 1 Service device SMX5000
• Simple operation with clear menu structure 1 Connection cable, 30-pin
2 1.5 V batteries, type AA (LR6)
• Operation and fault indication

Accessories
Battery 1.5 V Mignon, type AA (LR6) 906751
Technical specifications Connection cable, 30-pin 906198
LCD display 3 rows of 12 characters each
approx. 80 mA at 3 V Not included in delivery
(with background lighting) UniVario View software
Operating current approx. 25 mA at 3 V
(depends on the detector type) (without background lighting)
approx. 5 mA at 3 V
(in detector mode) Approvals / marking
approx. 25 hrs
(with background lighting)
Operation time
approx. 80 hrs
(depends on the detector
(without background lighting)
and battery types)
approx. 400 hrs
(in detector mode)
Batteries required 2 x 1.5 V Mignon, type AA (LR6)
IP rating IP 20
Enclosure material ABS plastic, RAL 7038 grey
0 °C to +50 °C
Operating temperature
(-32 °F to +122 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity 5 to 85%


(IEC 721-3-3) no condensation
EN 55022/CISPR22 CL. B,
Specification according to EN 55024, EN 61000-6-3,
EN 61000-4-2, EN 61000-4-3,
Weight 26 g (0.1 lbs)
165 x 92 x 30 mm (LxWxH)
Dimensions
6.5 x 3.6 x 1.2 inch (LxWxH)
312-911_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 48
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 Part no.: 801618


Double infrared flame detector FMX3511 for the detection
of open flames. Optic test monitors the functionality of the
detector. Designed for use in raugh industrial environments.
Equipped for operation as a conventional detector.

Product features Not included in delivery


• High degree of immunity against false alarms, Mounting device bracket with insulation 801284
e.g. from hot surfaces Mounting device console 125x80Ø60 801280
End of line-resistor 1.8 K / 0.5 W  675235
• A microcontroller monitors the functionality. Faults can
Sun screen  801277
be indicated on the detector or on a separate line
Remote indicator LMX5000  908499
• Connection of remote indicator possible Plug for the pollution test  801079
• Single optic test
Connection / mounting
Connection cable standard detector 2-wire
Recommended cable LiYCY 5x0.5 mm2 (AWG 20)
Technical specifications
Cable gland  M16x1.5, Brass nickel-plated, EMV
Detection method 2 IR Sensors
Sensitivity class 3
Approvals / marking
Viewing angle 60 °
Operating voltage 7.6 V - 15 V DC G 296016 0786-CPD-20312
Quiescent current approx. 3 mA
Alarm current approx. 18 mA
Alarm indication 1 LED red
Fault indication current approx. 7 mA
Fault indication 1 LED yellow
Number of detectors per line max. 4
Electrostatic shielding required
The contents of this publication are subject to modifications without notice. All rights reserved.

-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at + 35 °C (+95 °F)
(IEC 721-3-3)
Specification according to EN 54 Part 10
Weight 600 g (1.3 lbs)
127 x 125 x 70 mm (WxHxD)
Dimensions
5 x 4.9 x 2.8 inch (WxHxD)
312-330_003 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 49
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 SF Part no.: 801619


Silicone-free flame detector

FMX3511 0.2 sec Part no.: 902532


Flame detectors with fast response within range
of milsecounds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity

FMX3511 0.2 sec SF Part no.: 902767


Silicone-free flame detector
The contents of this publication are subject to modifications without notice. All rights reserved.
312-330_003 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 50
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 BG Part no.: 891319


Double infrared flame detector FMX3511 for the detection
of open flames. Optic test monitors the functionality of the
detector. Designed for use in raugh industrial environments.
Equipped for operation as a conventional detector.

Product features Not included in delivery


• High degree of immunity against false alarms, End of line-resistor 1.8 K / 0.5 W 675235
e.g. from hot surfaces Sun screen  801277
Remote indicator LMX5000  908499
• A microcontroller monitors the functionality. Faults can
Plug for the pollution test 801079
be indicated on the detector or on a separate line
• Connection of remote indicator possible
Connection /mounting
• Single optic test Connection cable standard detector 2-wire
Recommended cable LiYCY 5x0.5 mm2 (AWG 20)
Cable gland  M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method 2 IR Sensors Approvals / marking
Sensitivity class 3
G 296016 0786-CPD-20312
Viewing angle 60 °
Operating voltage 7.6 V - 15 V DC
Quiescent current approx. 3 mA
Alarm current approx. 18 mA
Alarm indication 1 LED red
Fault indication current approx. 7 mA
Fault indication 1 LED yellow
Number of detectors per line max. 4
Electrostatic shielding required
The contents of this publication are subject to modifications without notice. All rights reserved.

-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at + 35 °C (+95 °F)
(IEC 721-3-3)
Specification according to EN 54 Part 10
Weight 750 g (1.7 lbs)
127 x 155 x 92 mm (WxHxD)
Dimensions
5 x 6.1 x 3.6 inch (WxHxD)
312-330_004/ AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 51
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 BG SF Part no.: 800029


Silicone-free flame detector

FMX3511 BG 0.2 sec Part no.: 902533


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity

FMX3511 BG 0.2 sec SF Part no.: 902768


Silicone-free flame detector
The contents of this publication are subject to modifications without notice. All rights reserved.
312-330_004/ AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 52
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 Console Part no.: 801609


Double infrared flame detector FMX3511 for the detection
of open flames. Optic test monitors the functionality of the
detector. Version Brachet mounting. Designed for use in
rough industrial environments. Equipped for operation as
a conventional detector.

Product features Not included in delivery


• High degree of immunity against false alarms, Mounting device bracket with insulation 801284
e.g. from hot surfaces End of line-resistor 1.8 K / 0.5 W  675235
Sun screen  801277
• A microcontroller monitors the functionality. Faults can
Remote indicator LMX5000  908499
be indicated on the detector or on a separate line
Plug for the pollution test  801079
• Connection of remote indicator possible
• Single optic test Connection / mounting
Connection cable standard detector 2-wire
Recommended cable LiYCY 5x0.5 mm2 (AWG 20)
Cable gland  M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method 2 IR Sensors
Approvals / marking
Sensitivity class 3
Viewing angle 60 ° G 296016 0786-CPD-20312
Operating voltage 7.6 V - 15 V DC
Quiescent current approx. 3 mA
Alarm current approx. 18 mA
Alarm indication 1 LED red
Fault indication current approx. 7 mA
Fault indication 1 LED yellow
Number of detectors per line max. 4
Electrostatic shielding required
The contents of this publication are subject to modifications without notice. All rights reserved.

-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at + 35 °C (+95 °F)
(IEC 721-3-3)
Specification according to EN 54 Part 10
Weight 950 g (2.1 lbs)
127 x 150 x 75 mm (WxHxD)
Dimensions
5 x 5.9 x 3 inch (WxHxD)
312-330_005 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 53
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 Console 0.2 sec Part no.: 902534


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity
The contents of this publication are subject to modifications without notice. All rights reserved.
312-330_005 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 54
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 Console LSP Part no.: 801610


Double infrared flame detector FMX3511 for the detection
of open flames. Optic test monitors the functionality of the
detector. Version Brachet mounting and air flushing function.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.

Product features Not included in delivery


• High degree of immunity against false alarms, Mounting device bracket with insulation 801284
e.g. from hot surfaces End of line-resistor 1.8 K / 0.5 W  675235
Sun screen  801277
• A microcontroller monitors the functionality. Faults can
Remote indicator LMX5000  908499
be indicated on the detector or on a separate line
Plug for the pollution test  801079
• Connection of remote indicator possible Compressed air supply
• Single optic test Hose 6x4 PUN  914329
Hose 6x4 PUN ANTISTAT (Ex) 919559

Connection / mounting
Technical specifications
Connection cable standard detector 2-wire
Detection method 2 IR Sensors Recommended cable LiYCY 5x0.5 mm2 (AWG 20)
Sensitivity class 3 Cable gland  M16x1.5, brass nickel-plated, EMV
Viewing angle 60 °
Operating voltage 7.6 V - 15 V DC Approvals / marking
Quiescent current approx. 3 mA
Alarm current approx. 18 mA G 296016 0786-CPD-20312

Alarm indication 1 LED red


Fault indication current approx. 7 mA
Fault indication 1 LED yellow
Number of detectors per line max. 4
Electrostatic shielding required
The contents of this publication are subject to modifications without notice. All rights reserved.

-25 °C to +80 °C
Operating temperature
(-13 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at +35 °C (+95 °F)
(IEC 721-3-3)
Specification according to EN 54 Part 10
Compressed air supply on site Pressure range 0.8 - 1.5 bar
Hose connection internal 6 mm (0.24 inch)
312-330_006 / AI01_2016en

Weight 970 g (2.1 lbs)


141 x 150 x 75 mm (WxHxD)
Dimensions
5.6 x 5.9 x 3 inch (WxHxD)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 55
Product Sheet | Detecon

Industrial detectors
IR flame detector

FMX3511 Console LSP 0.2 sec Part no.: 902535


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity
The contents of this publication are subject to modifications without notice. All rights reserved.
312-330_006 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 56
Product Sheet | Detecon

Industrial detectors
IR flame detector, Ex

FMX3501 Ex Part no.: 903133


Infrared flame detector FMX3501 Ex for the detection
of open flames. Optic test monitors the functionality of the
detector. Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
Infrared flame detector FMX3501 Ex are ATEX-approved
for category 2 gas and 3 dust and are suitable for use
in Ex zones 1 and 22. Intrinsically safe flame detectors must
be connected by correspondingly marked cables to explosion
hazard barriers.

Product features Not included in delivery


• High degree of immunity against false alarms, Mounting device bracket with insulation 801284
e.g. from hot surfaces Safety barrier IS conventional 9 V 904991
End of line-resistor 1.8 K / 0.5 W 675235
• A microcontroller monitors the functionality. Faults
Sun screen 801277
can be indicated on the detector or on a separate line
Plug for the pollution test 801079
• Connection of remote indicator possible
• Single optic test Connection / mounting
Connection cable standard detector 2-wire
Recommended cable OB-BL-PAAR-CY 2x2x0.5 mm2
(AWG 20)
Technical specifications Cable gland M16x1.5, Brass nickel-plated, EMV

Detection method 2 IR Sensors


Sensitivity class 3
Approvals / marking
Ex conformity in acc. with 94/9/EG:
Viewing angle 60 °
x II 2G 3D Ex ib IIC T6/T4
Operating voltage 7.6 V - 15 V DC Type examination certificate: DMT 02 ATEX E224
Quiescent current approx. 3 mA Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T6/T4 Gb
Alarm current approx. 18 mA
Alarm indication 1 LED red
Fault indication current approx. 7 mA G 296016 0786-CPD-20312

Fault indication 1 LED yellow


Number of detectors per line max. 4
The contents of this publication are subject to modifications without notice. All rights reserved.

Electrostatic shielding required


-25 °C to +80 °C
Operating temperatur
(-4 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at +35 °C (+95 °F)
(IEC 721-3-3)
Weight 600 g (1.3 lbs)
127 x 125 x 70 mm (WxHxD)
Dimensions 5 x 4.9 x 2.8 inch (WxHxD)
312-340_002 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 57
Product Sheet | Detecon

Industrial detectors
IR flame detector, Ex

FMX3501 Ex SF Part no.: 903134


Silicone-free flame detector

FMX3501 Ex 0.2 sec Part no.: 903135


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity

FMX3501 Ex 0.2 sec SF Part no.: 903136


Silicone-free flame detector

FMX3501 Ex T Part no.: 903137


Flame detector with non-latching alarm

FMX3501 Ex T SF Part no.: 903138


Silicone-free flame detector
The contents of this publication are subject to modifications without notice. All rights reserved.

FMX3501 Ex T 0.2 sec Part no.: 903139


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity
312-340_002 / AI00_2015en

FMX3501 Ex T 0.2 sec SF Part no.: 903140


Silicone-free flame detector

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 58
Product Sheet | Detecon

Industrial detectors
IR flame detector, Ex

FMX3501 Ex BG Part no.: 800000


Infrared flame detector FMX3501 Ex for the
detection of open flames. Optic test monitors
the functionality of the detector.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
Infrared flame detector FMX3501 Ex are ATEX-approved
for category 2 gas and 3 dust and are suitable for use
in Ex zones 1 and 22.
Intrinsically safe flame detectors must be connected by
correspondingly marked cables to explosion hazard barriers.

Product features Not included in delivery


• High degree of immunity against false alarms, Safety barrier IS conventional 9 V 904991
e.g. from hot surfaces End of line-resistor 1.8 K / 0.5 W 675235
Sun screen 801277
• A microcontroller monitors the functionality. Faults
Plug for the pollution test 801079
can be indicated on the detector or on a separate line
• Connection of remote indicator possible
Connection / mounting
• Single optic test Connection cable standard detector 2-wire
Recommended cable OB-BL-PAAR-CY 2x2x0.5 mm2
(AWG 20)
Cable gland M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method 2 IR Sensors
Approvals / marking
Sensitivity class 3
Ex Conformity in acc. with 94/9/EG:
Viewing angle 60 ° x II 2G 3D Ex ib IIC T6/T4
Operating voltage 7.6 V - 15 V DC Type examination certificate: DMT 02 ATEX E224
Ex conformity Russia in acc. with TP TC 012/2011:
Quiescent current approx. 3 mA
1Ex ib IIC T6/T4 Gb
Alarm current approx. 18 mA
Alarm inducation 1 LED red
Fault indication current approx. 7 mA G 296016 0786-CPD-20312

Fault indication 1 LED yellow


Number of detektors per line max. 4
Electrostatic shielding required
The contents of this publication are subject to modifications without notice. All rights reserved.

-25 °C to +80 °C
Operating temperature
(-4 °F to +176 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009-blue
Relative humidity
max. 100% at +35 °C (+95 °F)
(IEC 721-3-3)
Weight 750 g (1.6 lbs)
127 x 155 x 92 mm (WxHxD)
Dimensions
5 x 6.1 x 3.6 inch (WxHxD)
250-111_003 / AI00_2015en

FMX3501 Ex BG CN Part no.: 907436


Version China Approvals / marking
Otherwise like part no. 800000

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 59
Product Sheet | Detecon

Industrial detectors
IR flame detector, Ex

FMX3501 Ex SF BG Part no.: 902769


Silicone-free flame detector

FMX3501 Ex 0.2 sec BG Part no.: 902721


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity

FMX3501 Ex 0.2 sec SF BG Part no.: 902770


Silicone-free flame detector

FMX3501 Ex T BG Part no.: 903141


Flame detector with non-latching alarm

FMX3501 Ex T SF BG Part no.: 903142


Silicone-free flame detector
The contents of this publication are subject to modifications without notice. All rights reserved.

FMX3501 Ex T 0.2 sec BG Part no.: 903143


Flame detectors with fast response within range
of miliseconds are used for object monitoring
(e.g. tooling machine)

Technical specifications
Criterion of detection change of intensity
250-111_003 / AI00_2015en

FMX3501 Ex T 0.2 sec SF BG Part no.: 903151


Silicone-free flame detector Otherwise like part no. 800000

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 60
Product Sheet | Detecon

Industrial detectors
UV flame detector, Ex

UMX3001 Ex Part no.: 903802


UV flame detector for the detection of open flames.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
The UMX3001 Ex flame detectors are ATEX-approved for
category 2 gas and dust and are suitable for use in Ex zones
1 and 21. The UMX3001 Ex has a pressure resistant casing.

Product features Not included in delivery


• Wide field of view End of line-resistor 1.8 K / 0.5 W 675235
• Fast flame response
• High water and dust protection (IP 67) Connection / mounting
Connection cable standard detector2-wire
Additional connection latching indication 1-wire
Recommended cable  LIYCY grey 5x0.5 mm2
Technical specifications (AWG 20)
Conductor cross-section max. 2.5 mm2 (AWG 13)
Detections method UV-Sensor
Conducting cable diameter 5 mm to 9 mm (0.20 to 0.35 inch)
Viewing angle 110 ° Cable gland metal, EMV, Ex M16x1.5
Number of detectors per line max. 4
Operating voltage 7.6 V - 13.2 V DC Approvals / marking
Quiescent cuttent approx. 1 mA Ex conformity in acc. with 94/9/EG: x II 2G Ex d e IIC T6
Alarm current approx. 20 mA x II 2D Ex tD A21 IP67 T80°C
Type examination certificate: BVS 04 ATEX E 168 X
Alarm indication 1 LED red
Electrostatic shielding requiered
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 67
Diecast aluminium,
Enclosure material
silver grey
Relative humidity
max. 95% to +35 °C (95 °F)
(IEC 721-3-3)
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 3 kg (6.6 lbs)


88 x 190 mm (dia. x H)
Dimensions
3.5 x 7.5 inch (dia. x H)
312-320_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 61
Product Sheet | Detecon

Industrial detectors
Detector accessories

Mounting device console 80x75 Ø54 Part no.: 902898


(3.1x2.9 Ø 2.1 inch) Mounting device to support gas emission detectors
GMX1001CO I.

Included in delivery
1 Mounting device console 80x75 Ø54 complete 902896
2 Countersunk screw DIN923-M5x10 St  835703
5 Self-taping screw DIN7981 C4.2x16  885080
5 Blind rivet 3.2x16 alu  885078
1 O-ring 60x3 Viton  132587
2 Hex screw DIN933-M8x20-A2  772552
2 Spring washer DIN127 B8-1.4310  820707

Not included in delivery


Technical specifications Adhesive LoctiteAVX 586, 50 ml 886226
Material Plastic POM
Colour black Note
Do not install the mounting device console in
Weight 160 g (0.4 lbs)
explosion-hazard zone 1
112 x 112 mm (LxW)
Dimensions
(4.4 x 4.4 inch (LxW)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 62
Product Sheet | Detecon

Industrial detectors
Detector accessories

Mounting device console 125x80 Ø60 Part no.: 801280


(4.9x3.1 Ø 2.3 inch) Mounting device to support flame detector FMX3511.

Included in delivery
1 Mounting device console 125x80 Ø60 801069
2 Countersunk screw DIN923-M5x10 St 835703
5 Self-taping screw DIN7981 C4.2x16  885080
5 Blind rivet 3.2x16 alu  885078
1 O-ring 70x3 Viton 70°SH  800774
2 Hex screw DIN933-M8x20-A2  772552
2 Spring washer DIN127 B8-1.4310  820707

Not included in delivery


Adhesive LoctiteAVX 586, 50 ml 886226
Technical specifications
Material Plastic PETP Note
Colour black Do not install the mounting device console in
Weight 350 g (0.8 lbs) explosion-hazard zone 1
120 x 150 mm (LxW)
Dimensions
(4.7 x 5.9 inch (LxW)

Mounting device console 125x80 Ø60 Part no.: 801281


(4.9x3.1 Ø 2.3 inch) LSP Mounting device with air flushing to support and preventive
cleaning of the detector optics of flame detectors FMX3511.

Included in delivery
1 Mounting device console 125x80 Ø60 LSP 801298
2 Countersunk screw DIN923-M5x10 St  835703
5 Self-taping screw DIN7981 C4.2x16  885080
5 Blind rivet 3.2x16 alu  885078
1 O-ring 60x3 Viton 70°SH 800774
2 Hex screw DIN933-M8x20-A2  772552
2 Spring washer DIN127 B8-1.4310  820707

Not included in delivery


Adhesive Loctite AVX 586, 50 ml 886226
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications Hose 6x4 PUN  914329


Medium Compressed air Hose 6x4 PUN ANTISTAT (Ex) 919559
Pressure range 0.8 - 1.5 bar Air flushing has to be supplied with compressed air on site
Connection thread G1/8“, DIN ISO228
Material Plastic PEPT
Note
Colour black Do not install the mounting device console in
Hose connection 6 mm (0.24 inch) explosion-hazard zone 1
Weight 370 g (0.8 lbs)
120 x 150 mm (LxW)
Dimensions
(4.7 x 5.9 inch (LxW)
312-810_013 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 63
Product Sheet | Detecon

Industrial detectors
Detector accessories

Mounting device bracket with insulation Part no.: 801284


Mounting device to support gas emission detectors, flame
detectors, spark detectors and spark test light detectors.

Included in delivery
1 Mounting device complete with 2 oval-head screw M8x12
for fixing the detector on the bracket

Not included in delivery


Clamping screw for wall/ceiling mounting

Spare parts
Oval-head screw M8x12-1.4301  800596
Technical specifications Hex. nut DIN934-M8-A2/A4  820781
Spring washer DIN127 B8-1.4310 820707
Stainless steel, 2 mm
Material bracket
(0.08 inch) thick
Stainless steel, 1.5 mm
Material clamp
(0.06 inch) thick
Insulating Plastic POM
Weight 160 g (0.4 lbs)
81.5 x 86 x 31 mm (LxWxH)
Dimensions
(3.2 x 3.4 x1.2 inch (LxWxH)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 64
Product Sheet | Detecon

Industrial detectors
Detector accessories

Set disk mounting 90 °C (194 °F) Part no.: 891848


Quick installation device to support detectors
with single-hole. The installation is allowed up to
a wall thickness of 8 mm (0.3 inch).

Technical specifications
Enclosure material
- mounting coupling Stainless steel
- hex. nut Brass
- oval washer Stainless steel
- tapered block Polyamid PA12, black
Operating temperature to +90 °C (+194 °F)
Weight 120 g (0.3 lbs)

Set disk mounting 250 °C (482 °F) Part no.: 800034


Quick installation device to support detectors
with single-hole and fibre options

Technical specifications
Enclosure material
Peck / Mod, black
tapered block 250 °C (482 °F)
Operating temperature to +250 °C (+482 °F)

Otherwise like part no. 891848

Flushing air device Part no.: 907822


Quick installation device to support detectors
with single-hole and air flushing

Not included in delivery


Hose 6x4 PUN  914329
Hose 6x4 PUN ANTISTAT (Ex) 919559
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Enclosure material V2A and PA 12
-10 °C to +60 °C
Operating temperature
(-14 °F to +140 °F)
Operating pressure 0.2 to 10 bar
Hose connection 6 mm (0.24 inch)
Weight 200 g (0.4 lbs)
55 x 48 mm (DxL)
Dimensions
2.2 x 1.9 inch (DxL)
312-810_002 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 65
Product Sheet | Detecon

Industrial detectors
Detector accessories

Mounting tool disk mounting - F180 Part no.: 843474

Technical specifications
Enclosure material Stainless spring band steel
Weight 90 g (0.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-810_002 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 66
Product Sheet | Detecon

Industrial detectors
Flame detector accessories

Sun screen FMX3511/FMX3501 Ex Part no.: 801277

Protection against unwanted radiation


(e.g. sunlight of outdoor applications) for the
flame detector FMX3511 and FMX3501 Ex.

Connection / mounting
Plug sun screen onto detector optic.

Note
After mounting the sunscreen can not be removed

Technical specifications
Stainless steel, 2.5 mm
Material
(0.09 inch) thick
62.5 x 53 mm (WxH)
Dimensions
2.5 x 2.1 inch (WxH)
Colour internally black
Weight 90 g (0.2 lbs)

Cleaning kit optic Part no.: 916644


To clean the optic and reflective surface of flame detectors.

Included in delivery
1 packaging unit
(20 cleaning cloth and 10 cleaning sponge)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-391_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 67
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO I Part no.: 900960


Multi sensor fire gas detector GMX1001CO I for the early
detection of smoldering fires. Designed for use in rough
industrial environments (e.g. silos, chip bunkers).
The GMX1001CO I detects the burning characteristic
substance carbon monoxide and temperature.
False alarms are nearly impossible. Equipped for
operation as a conventional detector.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device bracket with insulation 801284
Mounting device console 80x75 Ø54 902898
• Multi sensor carbon monoxide and temperature
End of line-resistor 1.8 K / 0,5 W  675235
• Connection of remote indicator possible Test device smoke generator RG2000  902671
Remote indicator LMX5000  908499

Technical specifications Connection / mounting


Connection cable standard detector 2-wire
CO (carbon monoxide)
Detection method Conductor cross-section  max. 2.5 mm2 (AWG 13)
and temperature
Fire detection cable with static shield 606061
Alarm threshold: LIYCY grey 5x0.5 mm2 (AWG 20)
≥ 40 ppm Cable gland M16x1.5, Brass nickel-plated, EMV
- Carbon monoxide
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T
- Rate of rise measurement
> 36 °C (96,8 °F) Spare parts
Operating voltage 7,6 V - 40 V DC Screwed mounting GMX1001COI complete 902923
Quiescent current approx. 0.15 mA Sensor GMX1002CO  900968
Alarm current approx. 18 mA
Alarm indication 1 LED red
Note
Simple one man calibration
Electrostatic shielding required
-20 °C to +50 °C
Operating temperature Approvals / marking
(-4 °F to +122 °F)
IP rating (EN 60529) IP 65
G 204121 0786-CPD-20135
Diecast aluminium,
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material
RAL 5009-blue
Relative humidity max. 15 to +90 %
(IEC 721-3-3) no condensation
Specification according to EN 54-5
Weight 480 g (1.1 lbs)
122 x 80 x 69 mm (WxHxD)
Dimensions
4.8 x 3.2 x 2.7 inch (WxHxD)
312-610_001 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 68
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO 300ppm Part no.: 909139


Special detector for application in areas with emissions of
carbon monoxide increased due to operating conditions.

Technical specifications Approvals / marking

Response monoxide
≥ 300 ppm
- Carbon monoxide
> 100 °C (212 °F)
- Temperature
dT > 3 °C/min. at T
- Differential measurement
> 80 °C (176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-610_001 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 69
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO I BG Part no.: 902891


Multi sensor fire gas detector GMX1001CO I BG
for the early detection of smoldering fires.
Designed for use in rough industrial environments
(e.g. silos, chip bunkers). The GMX1001CO I detects
the burning characteristic substance carbon monoxide
and temperature. False alarms are nearly impossible.
Designed for operation as a conventional detector.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device console 80x75 Ø54 902898
End of line-resistor 1.8 K / 0.5 W  675235
• Multi sensor carbon monoxide and temperature
Test device smoke generator RG2000 902671
• Connection of remote indicator possible Remote indicator LMX5000  908499

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
CO (carbon monoxide)
Detection method Fire detection cable with static shield 606061
and temperature
LIYCY grey, 5x0.5 mm2 (AWG 20)
Alarm threshold: Cable gland M16x1.5, Brass nickel-plated, EMV
≥ 40 ppm
- Carbon monoxide
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T Spare parts
- Rate of rise measurement
> 36 °C (96,8 °F) Screwed mounting GMX1001COI complete 902923
Operating voltage 7.6 V - 40 V DC Sensor GMX1002CO  900968
Quiescent current approx. 0.15 mA
Alarm current approx. 18 mA Note
Alarm indication 1 LED red Simple one man calibration
Electrostatic shielding required
-20 °C to +50 °C Approvals / marking
Operating temperature
(-4 °F to +122 °F)
IP rating (EN 60529) IP 65 G 204121 0786-CPD-20135
Diecast aluminium,
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material
RAL 5009-blue
Relative humidity max. 15 to +90 %
(IEC 721-3-3) no condensation
Specification according to EN 54-5
Weight 600 g (1.3 lbs)
122 x 106 x 88 mm (WxHxD)
Dimensions
4.8 x 4.2 x 3.5 inch (WxHxD)
312-610_002 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 70
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO 300ppm BG Part no.: 909161


Special detector for application in areas with emissions of
carbon monoxide increased due to operating conditions.

Technical specifications Approvals / marking

Response values
≥ 300 ppm
- Carbon monoxide
> 100 °C (212 °F)
- Temperature
dT > 3 °C/min. at T
- Differential measurement
> 80 °C (176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-610_002 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 71
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO I Console Part no.: 902893


Multi sensor fire gas detector GMX1001CO I Console
for the early detection of smoldering fires. Designed for use
in rough industrial environments (e.g. silos, chip bunkers).
Version bracket mount. The GMX1001CO I detects the
burning characteristic substance carbon monoxide and
temperature. False alarms are nearly impossible.
Designed for operation as a conventional detector.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device bracket with insulation 801284
End of line-resistor 1.8 K / 0.5 W  675235
• Multi sensor carbon monoxide and temperature
Test device smoke detector RG2000  902671
• Connection of remote indicator possible Remote indicator LMX5000  908499

Connection / mounting
Technical specifications Connection cable standard detector 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
CO (carbon monoxide)
Detection method Fire detection cable with static shield 606061
and temperature
LIYCY grey, 5x0.5 mm2 (AWG 20)
Alarm threshold: Cable gland M16x1.5, Brass nickel-plated, EMV
≥ 40 ppm
- Carbon monoxid
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T Spare parts
- Rate of rise measurement
> 36 °C (96.8 °F) Screwed mounting GMX1001COI complete 902923
Operating voltage 7.6 V - 40 V DC Sensor GMX1002CO  900968
Quiescent current approx. 0.15 mA
Alarm current approx. 18 mA Note
Alarm indication 1 LED red Simple one man calibration
Electrostatic shielding required
-20 °C to +50 °C Approvals / marking
Operating temperature
(-4 °F to +122 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material
RAL 5009-blue
Relative humidity max. 15 at +90 %
(IEC 721-3-3) no condensation
Weight 600 g (1.3 lbs)
122 x 112 x 75 mm (WxHxD)
Dimensions
4.8 x 4.4 x 3 inch (WxHxD)
312-610_003 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 72
Product Sheet | Detecon

Industrial detectors
Gas emission detector

GMX1001CO 300ppm Console Part no.: 909162


Special detector for application in areas with emissons of
carbon monoxide increased due to operating conditions.

Technical specifications Approvals / marking

Response values
≥ 300 ppm
- Carbon monoxide
> 100 °C (212 °F)
- Temperature
dT > 3 °C/min. at T
- Differential measurement
> 80 °C (176 °F)
The contents of this publication are subject to modifications without notice. All rights reserved.
312-610_003 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 73
Product Sheet | Detecon

Industrial detectors
Gas emission detector, Ex

GMX1001CO Ex Dust Part no.: 905642


Multi sensor fire gas detector GMX1001CO Ex Dust
for the early detection of smoldering fires. Designed for use
in raugh industrial environments (e.g. silos, chip bunkers).
The GMX1001CO I detects the burning characteristic
substance carbon monoxide and temperature.
False alarms are nearly impossible. Designed for operation
as a conventional detector. The GMX1001CO Ex Dust gas
detectors are ATEX-approved for category 1 and 2 dust and
are suitable for use in Ex zone 20 and 21.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device bracket with insulation 801284
Mounting device console 80x75Ø54 902898
• Multi sensor carbon monoxide and temperature
End of line-resistor 1.8 K / 0.5 W  675235
• Connection of remote indicator possible Test device smoke generator RG2000  902671
Remote indicator LMX5000  908499

Technical specifications Connection / mounting


Connection cable standard detector  2-wire
CO (carbon monoxide)
Detection method Conductor cross-section  max. 2.5 mm2 (AWG 13)
and temperature
Fire detection cable with static shield 606061
Alarm threshold LIYCY grey, 5x0.5 mm2 (AWG 20)
≥ 40 ppm Cable gland M16x1.5, Brass nickel-plated, EMV, Ex
- Carbon monoxide
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T
- Rate of rise measurement
> 36 °C (96.8 °F) Spare parts
Number of detectors per line max. 32 Screwed GMX1001COI complete 902923
Operating voltage 7.6 V - 40 V DC Sensor GMX1002CO  900968
Quiescent current approx. 0.15 mA
Alarm current approx. 18 mA
Note
Simple one man calibration
Alarm indication 1 LED red
Electrostatic shielding required
Approvals
-20 °C to +50 °C Ex conformity in acc. with 94/9/EG:
Operating temperature
(-4 °F to +122 °F)
x II 1/2D Ex tD A20/21 IP65 T136°C
IP rating (EN 60529) IP 65
The contents of this publication are subject to modifications without notice. All rights reserved.

x II 1D Ex tD A20 IP65 T136°C


Enclosure material
Diecast aluminium, Type examination certificate: BVS 05 ATEX E179
RAL 5009-blue
Relative humidity max. 15 at + 90 %
(IEC 721-3-3) no condensation
Approvals / marking
Specification according to EN 54-5
G 204121 0786-CPD-20135
Weight 480 g (1.1 lbs)
122 x 80 x 69 mm (WxHxD)
Dimensions
4.8 x 3.2 x 2.7 inch (WxHxD)
312-620_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 74
Product Sheet | Detecon

Industrial detectors
Gas emission detector, Ex

GMX1001CO Ex Dust BG Part no.: 905643


Multi sensor fire gas detector GMX1001CO Ex Dust BG
for the early detection of smoldering fires. Designed for use
in raugh industrial environments (e.g. silos, chip bunkers).
The GMX1001CO I detects the burning characteristic
substance carbon monoxide and temperature.
False alarms are nearly impossible. Designed for operation
as a conventional detector. The GMX1001CO Ex Dust BG
gas detectors are ATEX-approved for category 1 and 2 dust
and are suitable for use in Ex zone 20 and 21.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device console 80x75Ø54 902898
End of line-resistor 1.8 K / 0.5 W  675235
• Multi sensor carbon monoxide and temperature
Test device smoke generator RG2000  902671
• Connection of remote indicator possible Remote indicator LMX5000  908499

Connection / mounting
Technical specifications Connection cable standard detector  2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
CO (carbon monoxide)
Detection method Fire detection cable with static shield  606061
and temperature
LIYCY grey, 5x0.5 mm2 (AWG 20)
Alarm threshold Cable gland  M16x1.5, Brass nickel-plated, EMV, Ex
≥ 40 ppm
- Carbon monoxide
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T Spare parts
- Rate of rise measurement
> 36 °C (96.8 °F) Screwed GMX1001COI complete  902923
Operating voltage 7.6 V - 40 V DC Sensor GMX1002CO  900968
Quiescent current approx. 0.15 mA
Alarm current approx. 18 mA Note
Alarm indication 1 LED red Simple one man calibration
Electrostatic shielding required
-20 °C to +50 °C
Approvals / marking
Operating temperature Ex conformity in acc. with 94/9/EG:
(-4 °F to +122 °F)
IP rating (EN 60529) IP 65
 x II 1/2D Ex tD A20/21 IP65 T136°C
 x II 1D Ex tD A20 IP65 T136°C
Diecast aluminium,
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material Type examination certificate: BVS 05 ATEX E179


RAL 5009-blue
Relative humidity max. 15 to + 90 %
(IEC 721-3-3) no condensation G 204121 0786-CPD-20135
Specification according to EN 54-5
Weight 600 g (1.3 lbs)
122 x 106 x 88 mm (WxHxD)
Dimensions
4.8 x 4.2 x 3.5 inch (WxHxD)
312-620_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 75
Product Sheet | Detecon

Industrial detectors
Gas emission detector, Ex

GMX1001CO Ex Dust Console Part no.: 905644


Multi sensor fire gas detector GMX1001CO Ex Dust Console
for the early detection of smoldering fires. Designed for use
in rough industrial environments (e.g. silos, chip bunkers).
Version bracket mount. The GMX1001CO I detects the
burning characteristic substance carbon monoxide and
temperature. False alarms are nearly impossible.
Equipped for operation as a conventional detector.
The GMX1001CO Ex Dust Console gas detectors are
ATEX-approved for category 1 and 2 dust and are suitable
for use in Ex zone 20 and 21.

Product features Not included in delivery


• A microcontroller monitors the functionality and values Mounting device bracket with insulation 801284
End of line-resistor 1.8 K / 0.5 W  675235
• Multi sensor carbon monoxide and temperature
Test device smoke generator RG2000  902671
• Connection of remote indicator possible Remote indicator LMX5000  908499

Connection / mounting
Technical specifications Connection cable standard detector  2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
CO (carbon monoxide)
Detection method Fire detection cable with static shield  606061
and temperature
LIYCY grey, 5x0.5 mm2 (AWG 20)
Alarm threshold Cable gland  M16x1.5, Brass nickel-plated, EMV, Ex
≥ 40 ppm
- Carbon monoxide
> 60 °C (140 °F)
- Temperature
dT > 3 °C/min. at T Spare parts
- Rate of rise measurement
> 36 °C (96.8 °F) Screwed GMX1001COI complete 902923
Operating voltage 7.6 V - 40 V DC Sensor GMX1002CO  900968
Quiescent current approx. 0.15 mA
Alarm current approx. 18 mA Note
Alarm indication 1 LED red Simple one man calibration
Electrostatic shielding required
-20 °C to +50 °C
Approvals / marking
Operating temperature Ex conformity in acc. with 94/9/EG:
(-4 °F to +122 °F)
IP rating (EN 60529) IP 65
 x II 1/2D Ex tD A20/21 IP65 T136°C
 x II 1D Ex tD A20 IP65 T136°C
Diecast aluminium,
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure material Type examination certificate: BVS 05 ATEX E179


RAL 5009-blau
Relative humidity max. 15 to + 90 %
(IEC 721-3-3) no condensation 0786-CPD-20135
Weight 600 g (1.3 lbs)
122 x 112 x 75 mm (WxHxD)
Dimensions
4.8 x 4.4 x 3 inch (WxHxD)
312-620_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 6 - 76
Product Sheet | Detecon

Aspirating smoke detectors


AMX4004, basic devices

AMX4004 Part no.: 909244


The aspirating smoke detector AMX4004 is an active
smoke detection system that can be individually tuned to
the application area with up to three different detector heads.
Up to 12 suction holes with a 100 m (328 ft) pipe system
are possible thanks to the powerful fan.

Product features Application


• Up to three combined sensors can be used for different Aspirating smoke detector for the detection of smoke
application areas (scattered light smoke sensor, particles and/or fire gases in aspirated air samples.
ionisation smoke sensor, carbon monoxide gas sensor) The system actively draws air samples from the monitored
area via a pipe system.
• High aspiration capacity
• Scattered light smoke sensors for different Typical application areas are:
sensitivity ranges, with pollution compensation - Equipment monitoring: computer rooms, warehouses,
for use in critical environments high rack storage areas, hollow floors.
- cultural assets protection, transformer stations, etc.
• Ionisation smoke sensor for detecting
very small and dark smoke particles
Included in delivery
• Carbon monoxide gas sensor for earliest
1 Aspirating smoke detector AMX4004 909244
fire detection (40 ppm CO)
• Integrated LC display for indicating status information
Not included in delivery
• Configurable without accessories (menu-controlled)
Detector heads:
Optical smoke detector OMX1002C 1HU,
2.73 % / m (0.83 % / ft) 906323
Technical specifications Optical smoke detector OMX1002C HS 1HU,
0.34 % / m (0.10 % / ft) 906324
Operating voltage 18 V - 30 V DC Optical smoke detector OMX1002C VHS 1HU,
Rated voltage 24 V DC 0.11 % / m (0.04 % / ft) 910389
Ionisation smoke detector IMX1002E 1HU, y=0.8 909491
Measuring principle dependent on detector heads
Carbon monoxide gas detector
Max. current consumption Detector approx. 400 mA GMX1002CO 1HU, 40 ppm 909492
Max. contact load 60 V DC, 1 A
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating IP 54 Note
-20 °C to +50 °C The AMX4004 uses three conventional lines for three alarms
Ambient temperature as well as one fault line for connection to the fire alarm panel
(-4 °F to +122 °F)
FMZ 5000. In addition floating contacts for three alarms as
Sampling pipe 25 mm (0.98 inch)
well as fault are available.
max. overall length 100 m (328 ft)
Sampling pipe length
max. 50 m (164 ft) as single strand
max. 95 %, Approvals / marking
Relative humidity
at 35 °C (+95 °F), no condensation
Enclosure material Die cast aluminium G 212001 0786-CPD-21095
4 x M16, clamping range 5-9 mm
Cable gland
(0.19 - 0.35 inch)
313-110_001 / AI01_2016en

Weight without detector head 3.4 kg (7.5 lbs)


Dimensions 280 x 170 x 90 mm (WxHxD)
without cable gland 11.02 x 6.7 x 3.5 inch (WxHxD)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 1
Product Sheet | Detecon

Aspirating smoke detectors


AMX4004, basic devices

AMX4004 IT AP NEW Part no.: 921108

Complete device especially for use in IT facilities. Included in delivery


Integrated optical smoke detector OMX1002C HS 1HE and 1 Aspirating smoke detector AMX4004 909244
optical smoke detector OMX1002C VHS 1HE. 1 Input module IUX 760 M-I 908531
Prepared to connect to analogue addressable Loop AP by Detector heads:
integrated modul with dual isolator. 1 Optical smoke detector OMX1002C HS 1HU 906324
1 Optical smoke detector OMX1002C VHS 1HU 910389

Technical specifications
Weight 3.7 kg (8.2 lbs) Otherwise like part no.: 909244

AMX4004 WEA Part no.: 909043


Basic device especially for use in wind turbines
(with integrated controlled heating)

Technical specifications
Max. current consumption Heating approx. 1.4 A Otherwise like part no.: 909244
The contents of this publication are subject to modifications without notice. All rights reserved.
313-110_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 2
Product Sheet | Detecon

Aspirating smoke detectors


AMX4004, detector heads

Optical smoke detector OMX1002C 1HU Part no.: 906323

Technical specifications
Sensitivity 2.73 % / m (0.83 % / ft)
Weight 0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
Dimensions
2.16 x 1.57 inch (DxH)

Optical smoke detector OMX1002C HS Part no.: 906324


1HU
Technical specifications
Sensitivity 0.34 % / m (0.10 % / ft)
Weight 0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
Dimensions
2.16 x 1.57 inch (DxH)

Optical smoke detector OMX1002C VHS Part no.: 910389


1HU
Technical specifications
Sensitivity 0.11 % / m (0.04 % / ft)
Weight 0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
Dimensions
2.16 x 1.57 inch (DxH)

Ionisation smoke detector IMX1002E 1HU Part no.: 909491

Technical specifications
Sensitivity y = 0.8
Weight 0.1 kg (0.02 lbs)
55 x 40 mm (DxH)
Dimensions
2.16 x 1.57 inch (DxH)
The contents of this publication are subject to modifications without notice. All rights reserved.

Carbon monoxide gas detector GMX1002 Part no.: 909492


CO 1HU
Technical specifications
Trigger value
40 ppm
carbon monoxide
Weight 0.05 kg (0.05 lbs)
55 x 40 mm (DxH)
Dimensions
2.16 x 1.57 inch (DxH)
313-120_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 3
Product Sheet | Detecon

Aspirating smoke detectors


HELIOS AMX5000, basic devices

AMX5001 Part no.: 908095


The HELIOS AMX5000 aspirating smoke detector is a
highly sensitive active smoke detection system of the latest
generation. In addition to monitoring advance signals and
contamination, it also provides the option of the user-specific
adjustment of the sensitivity. The powerful fan enables up
to 50 sampling holes with 300 m (984 ft) pipe system per
smoke sensor. The HELIOS AMX5000 is even able to detect
the smallest smoldering fires and can be used practically
everywhere. Version AMX5001: basic device with simple
display. For 1 sampling pipe and 1 smoke sensor.

Product features Application


• Autolearning function Aspirating smoke detector for the detection of smoke
• Separate airflow monitoring with one or two aspiration lines particles by air sampling. The system takes on air sampling
probe in from the monitoring area via a pipe system.
• Adjustable sensitivity of 0.002 - 10 % / m
(0.0006 - 3.049 % / ft) Typical applications
• High sampling power (high negative pressure of 400 Pa) - Equipment monitoring:
• Highly sensitive smoke sensors with contamination IT systems, electrical distributors, switch cabinets, etc.
compensation for use in critical environments - Room monitoring: IT rooms, clean rooms, warehouses,
high rack storage areas, hollow floors, protection of objects
• Full integration into the Minimax fire alarm system
of cultural value, transformer stations, etc.
FMZ 5000
Included in delivery
1 Aspirating smoke detector AMX5001 908095
Technical specifications
Not included in delivery
Operating voltage 10.5 - 30 V DC
Smoke sensor OMX5005,
Rated voltage 24 V DC
0.5 % /m - 10 % / m (0.152 % / ft - 3.049 % / ft) 908099
0.02 % / m - 10 % / m
Alarm sensitivity
(0.006 % / ft - 3.049 % / ft)
Smoke sensor OMX5010,
0.1 % / m - 10 % / m (0.030 % / ft - 3.049 % / ft) 908100
0.002 - 10 % / m
Pre-Alarm signals 1,2,3 (0.0006 % / ft - 3.049 % / ft, Smoke sensor OMX5020,
programmable in increments of 10 % 0.02 % / m - 10 % / m (0.006 % / ft - 3.049 % / ft) 908101
Inactive/fault approx. 340 mA Relay module KMX5005 RK 908103
Max. current consumption Memory module MMX5005 908104
Alarm I approx. 390 mA
Number of relays 3 Configuration software HELIOS Config 908105
Max. contact load 50 V DC, 1 A Project planning software HELIOS PipeCalc 908106
IP rating IP 54
-30 °C to +60 °C
Spare parts
Ambient temperature
The contents of this publication are subject to modifications without notice. All rights reserved.

(-22 °F to +140 °F) Case fastener (4 pieces) 909434


Intake pressure > 400 Pa (power level 5) Air flow sensor HELIOS AMX5000 917702
Suction noise at fan level 3
43 dB (A)
(standard) Note
Number of installation spaces
4
The HELIOS AMX5000 can be connected to a higher-level
for add-on modules fire alarm panel via dry changeover contacts. The HELIOS
Sampling pipe Plug-in system 25 mm (0.98 inch) AMX5000 can be integrated into the FMZ5000 fire alarm
max. 95 %, system with LoopAP via modules. Indication and operation
Relative humidity temporarily without condensation are thus possible at the fire alarm panel.
70 %, constantly
Enclosure material ABS-Blend, UL 94-V0 Approvals / marking
Specification according to EN 54-20, classes A, B and C
313-310_001 / AI01_2016en

Weight 3.85 kg (8.5 lbs)


G 208193 0786-CPD-20637
265 x 397 x 146 mm (WxHxD)
Dimensions
10.4 x 15.6 x 5.8 inch (WxHxD)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 4
Product Sheet | Detecon

Aspirating smoke detectors


HELIOS AMX5000, basic devices

AMX5002 Part no.: 908096


Basic device with simple display.
For 2 aspiration tubes and 2 smoke sensors.

Technical specifications
Inactive/fault approx. 380 mA
Max. current consumption
Alarm I approx. 450 mA

AMX5101 Part no.: 908097

Basic device with 10-LED display.


For 1 aspiration tube and 1 smoke sensor.

Technical specifications
Inactive/fault approx. 340 mA
Max. current consumption
Alarm I approx. 405 mA

AMX5102 Part no.: 908098


Basic device with 10-LED display.
For 2 aspiration tubes and 2 smoke sensors.

Technical specifications
Inactive/fault approx. 380 mA
Max. current consumption
The contents of this publication are subject to modifications without notice. All rights reserved.

Alarm I approx. 490 mA


313-310_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 5
Product Sheet | Detecon

Aspirating smoke detectors


HELIOS AMX5000, detector heads

Smoke sensor OMX5005 Part no.: 908099

Technical specifications
0.05 % / m - 10 % / m
Sensitivity
(0.152 % / ft - 3.049 % / ft)
Weight 0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
Dimensions
5.90 x 4.92 x 3.74 inch (WxHxD)

Smoke sensor OMX5010 Part no.: 908100

Technical specifications
0.01 % / m - 10 % / m
Sensitivity
(0.030 % / ft - 3.049 % / ft)
Weight 0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
Dimensions
5.90 x 4.92 x 3.74 inch (WxHxD)

Smoke sensor OMX5020 Part no.: 908101

Technical specifications
0.002 % / m - 10 % / m
Sensitivity
(0.006 % / ft - 3.049 % / ft)
Weight 0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
Dimensions
5.90 x 4.92 x 3.74 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
313-320_001 / AI01_2016en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 6
Product Sheet | Detecon

Aspirating smoke detectors


HELIOS AMX5000, detector heads

Detector interface AMX1002 IF Part no.: 908102


Detector can be used to insert up to two detector heads.
Detection of pre-alarm and main alarm via the HELIOS
AMX5000.

Technical specifications
Weight 0.26 kg (0.56 lbs)
150 x 115 x 95 mm (WxHxD)
Dimensions
5.90 x 4.52 x 3.74 inch (WxHxD)

Optical smoke detector OMX1002 C Part no.: 801226


Detector head for use in the HELIOS AMX5000 via the
detector interface AMX1002 IF

Technical specifications
Sensitivity 2.73 % / m (0.83 % / ft)
Weight 0.07 kg (0.56 lbs)
55 x 55 mm (DxH)
Dimensions
2.16 x 2.16 inch (DxH)

Optical smoke detector OMX1002C HS Part no.: 904639


Detector head with increased sensitivity for use in the
HELIOS AMX5000 via the detector interface AMX1002 IF

Technical specifications
Sensitivity 0.34 % / m (0.10 % / ft)
Weight 0.07 kg (0.56 lbs)
55 x 55 mm (DxH)
Dimensions
2.16 x 2.16 inch (DxH)

Ionisation smoke detector IMX1002E Part no.: 797144


The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Sensitivity y = 0,8
Weight 0.06 kg (0.13 lbs)
55 x 55 mm (DxH)
Dimensions
2.16 x 2.16 inch (DxH)

Carbon monoxide gas detector Part no.: 900959


GMX1002 CO
Technical specifications
313-320_001 / AI01_2016en

Trigger value
40 ppm
carbon monoxide
Weight 0.06 kg (0.13 lbs)
55 x 35 mm (DxH)
Dimensions
2.16 x 1.37 inch (DxH)

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 7
Product Sheet | Detecon

Aspirating smoke detectors


HELIOS AMX5000, accessories

Accessories HELIOS AMX5x01 US Part no.: 910977


For use with aspirating smoke detector HELIOS AMX5001
and AMX5101 (1 aspiration tube) for „CPVC“ tubes.

Included in delivery
1 PVC pipe 25 x 1,5
1 Flexible hose
3 Adapter M20 x 1,5 - NPT 1/2“
1 Adapter M25 x 1,5 - NPT 3/4“

Accessories HELIOS AMX5x02 US Part no.: 911660


For use with aspirating smoke detector
HELIOS AMX5002 and AMX5102
(2 aspiration tubes) for „CPVC“ tubes.

Otherwise like part no.: 910977

Included in delivery
2 PVC pipes 25 x 1,5
1 Flexible hose
3 Adapter M20 x 1,5 - NPT 1/2“
1 Adapter M25 x 1,5 - NPT 3/4“
The contents of this publication are subject to modifications without notice. All rights reserved.
313-340_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 8
Product Sheet | Detecon

Aspirating smoke detectors


Vesda laser, basic devices

LaserFocus VLF-250 Part no.: 908495


The LaserFocus VLF-250 is designed to ensure extremely
early smoke detection for small and operationally critical
areas. The detector constantly takes air samples through
inlets to a pipe network where the air is filtered and sent
to a collection chamber. Using light dispersion technology,
the presence of even the smallest amounts of smoke
can be identified. An immediate airflow rate measuring
value display on the air inlet pipe presents the ultrasound
airflow rate reading. The system is resistant to changes in
air temperature and air pressure and is not damaged by
impurities.

Product features Included in delivery


• Two-leval air filtering 1 LaserFocus VLF-250
• AutoLearn alarm thresholds and air flow rate
• Ultrasonic airflow rate reading Not included in delivery
• Laser-based, absolute smoke identification Mounting hardware

• Programmable alarm threshold values


• Pre-set pipe network constructions
Approvals / marking
• Installation and start-up can be carried out
G 205060 0832-CPD-0771
in delivered condition

Technical specifications
Sensitivity range 0.025 - 20 %/m (39 inch)
0 °C to +40 °C
Ambient temperature
(32 °F to +104 °F)
Temperature 0 °C to +40 °C
of the aspirated air (32 °F to +104 °F)
Operating voltage 18 - 30 V DC
Rated voltage 24 V DC
Quiescent current 220 mA
Alarm current 295 mA
Rated output 5.2 W
The contents of this publication are subject to modifications without notice. All rights reserved.

Rated output for alarm 7.0 W


Areas of coverage max. 250 m (2691 square foot)
2

IP rating IP 30
1 x 25 m (984 inch),
Maximum pipe length
2 x 15 m (590 inch)
Event memory max. 18000 entries
Aspiration tube Plug-in system 25 mm (0.98 inch)
5 - 95 %,
Relative humidity
no condensation
313-410_001 / AI00_2015en

Colour of enclosure light grey


Specification according to EN 54-20
Weight 2.0 kg (4.4 lbs)
255 x 185 x 90 mm (WxHxD)
Dimensions
8.9 x7.3 x 3.5 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 9
Product Sheet | Detecon

Aspirating smoke detectors


Vesda laser, basic devices

LaserCompact VLC-400 AP Part no.: 908494


The LaserCompact detector VLC-400 AP is designed for
use with FMZ 5000 fire detection control panel with Loop
AP communication protocol. The VLC-400 AP is equipped
with an integrated loop isolator on the main processor card.
The detector units all the advantages of aspiration smoke
detection, including early warning in small areas. Via a simple
pipe network, a high-performance aspirator continuously
sucks air into a central detector. On the first level, dust
and dirt are filtered before the air reaches the early smoke
detector in the detector chamber. In order to guarantee
optimal response to a large variety of smoke types, a highly
effective laser light source and a sensor configuration are
used in the detector chamber.

Product features Included in delivery


• Large sensitivity range 1 LaserCompact VLC-400 AP
• AutoLearn
• Airflow monitoring Not included in delivery
• Absolute smoke detection Mounting hardware
• Compatible with Loop AP technology

Approvals / marking

Technical specifications G 203025 0832-CPD-0770


Sensitivity range 0.005 - 20 %/m (39 inch)
-10 °C to +39 °C
Ambient temperature
(+14 °F to +102.2 °F)
Temperature -20 °C to +60 °C
of the aspirated air (-4 °F to +140 °F)
Communication protocol Loop AP
Number of detectors per loop max. 126
Isolators 1 loop isolator
Operating voltage 18 - 30 V DC
Rated voltage 24 V DC
Quiescent current 225 mA
Alarm current 245 mA
Rated output 5.4 W
The contents of this publication are subject to modifications without notice. All rights reserved.

Rated output for alarm 5.9 W


Areas of coverage max. 800 m (8611 square feet)
2

IP rating IP 30
1 x 80 m (3150 inch),
Maximum pipe length
2 x 50 m (1968 inch)
Event memory max. 10240 entries
Aspiration tube Plug-in system 25 mm (0.98 inch)
10 - 95 %,
Relative humidity
mo condensation
Colour of enclosure light grey
313-410_002 / AI00_2015en

Weight 1900 g (4.2 lbs)


225 x 225 x 85 mm (WxHxD)
Dimensions
8.9 x 8.9 x 3.9 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 10
Product Sheet | Detecon

Aspirating smoke detectors


Vesda laser, basic devices

LaserCompact VLC-500 Part no.: 908492


The LaserCompact detector VLC-500 unites all the
advantages of aspirating smoke detection, including early
warning in small areas where space is of upmost importance.
Via a simple pipe network, a high-performance aspirator
continuously sucks air into a central detector. On the first
level, dust and dirt are filtered before the air reaches the
early smoke detector in the detector chamber. In order to
guarantee optimal response to a large variety of smoke
types, a highly effective laser light source and a sensor
configuration are used in the detector chamber. The status
of all detectors, alarms, maintenance and fault notifications
are monitored and saved with time and date stamps.

Product features Included in delivery


• Large sensitivity range 1 LaserCompact VLC-500
• Two-level dust filter
• AutoLearn Not included in delivery
• Airflow monitoring Mounting hardware
• Absolute smoke detection
• Three alarm settings Approvals / marking
(information, pre-alarm and main alarm)
• Three programmable relays G 298024 0832-CPD-0770
• Single pipe inlet
• Simple built-in construction

Technical specifications
Sensitivity range 0.005 - 20 %/m (39 inch)
-10 °C to +39 °C
Ambient temperature
(+14 °F to +102.2 °F)
Temperature -20 °C to +60 °C
of the aspirated air (-4 °F to +140 °F)
Operating voltage 18 - 30 V DC
Rated voltage 24 V DC
Quiescent current 225 mA
Alarm current 245 mA
The contents of this publication are subject to modifications without notice. All rights reserved.

Rated output 5.4 W


Rated output for alarm 5.9 W
Areas of coverage max. 800 m2 (8611 square feet)
IP rating IP 30
1 x 80 m (3150 inch),
Maximum pipe length
2 x 50 m (1968 inch)
Event memory max. 12000 entries
Aspiration tube Plug-in system 25 mm (0.98 inch)
10 - 95 %,
Relative humidity
313-410_003 / AI00_2015en

no condensation
Colour of enclosure light grey
Weight 1900 g (4.2 lbs)
225 x 225 x 85 mm (WxHxD)
Dimensions
8.9 x 8.9 x 3.4 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 11
Product Sheet | Detecon

Aspirating smoke detectors


Sampling pipes

Pipe 25 x 1.5 mm (98 x 0.06 inch) Part no.: 905253

Technical specifications
Material PVC pressure pipe, grey, 10 bar
Weight 1.0 kg (2.2 lbs)
Length 5000 mm (196.9 inch)

Sleeve 25 mm (98 inch) Part no.: 905264

Technical specifications
Material PVC, grey, 16 bar
Weight 0.01 kg (0.02 lbs)

Adhesive cap 25 mm (98 inch) Part no.: 905263

Technical specifications
Material PVC, grey, 16 bar
Weight 0.01 kg (0.02 lbs)

Elbow 90° 25 x 13.5 mm (98 x 0.53 inch) Part no.: 905255

Technical specifications
Material PVC, grey, 16 bar
Weight 0.03 kg (0.07 lbs)

Bend 90° 25 x 37.5 mm (98 x 1.37 inch) Part no.: 905254

Technical specifications
Material PVC, grey, 16 bar
Weight 0.05 kg (0.1 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Elbow 45° 25 x 6 mm (98 x 0.23 inch) Part no.: 905256

Technical specifications
Material PVC, grey, 16 bar
Weight 0.03 kg (0.07 lbs)

T-piece 90° 3 x 25 mm (0.11 x 98 inch) Part no.: 905262


313-810_001 / AI01_2016en

Technical specifications
Material PVC, grey, 16 bar
Weight 0.03 kg (0.07 lbs)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 12
Product Sheet | Detecon

Aspirating smoke detectors


Sampling pipes

Coupling 25 mm (98 inch) Part no.: 905265

Technical specifications
Material PVC, grey, 16 bar
Weight 0.06 kg (0.1 lbs)

Hose piece for active detector Part no.: 904393

Technical specifications
Material PVC hose with steel reel
Weight 0.15 kg (0.33 lbs)
Length 350 mm (0.3 inch)

Hose flexible D21 grey Part no.: 834784

Technical specifications
Material PVC hose flexible
Weight 2.5 kg (5.5 lbs)
Length cable roll to 10 m (394 inch)

Ceiling duct set, PVC, d=21.2 Part no.: 908699


Complete suction set for installation in the PVC sensor pipe
system d=25 mm (0.98 inch), e.g. for suspended ceilings, for
taking air samples from a room. Length: 0.8 m (31.5 inch).

Air duct set ASD NEW Part no.: 916325

Air duct set ASD for quick and easy installation of the suction-
pipe in the air duct.
Application with set disk mounting.
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
PVC grey 16 bar
Material
Stainless steel/Brass/PA12
Weight 0.29 kg (0.64 lbs)
313-810_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 13
Product Sheet | Detecon

Aspirating smoke detectors


Aspirating pipes - connections/accessories

Pipe clamp 25 - 28 mm (0.98 - 1.10 inch) Part no.: 905266

Technical specifications
Material PP grey
Weight 0.01 kg (0.02 lbs)

Sampling hole clip d=2.0 mm (0.08 inch) red Part no.: 908331

Sampling hole clip d=2.5 mm (0.09 inch) red Part no.: 908332

Sampling hole clip d=3.0 mm (0.11 inch) red Part no.: 908333

Sampling hole clip d=3.5 mm (0.14 inch) red Part no.: 908334

Sampling hole clip d=4.0 mm (0.16 inch) red Part no.: 908335

Sampling hole clip d=4.5 mm (0.18 inch) red Part no.: 908336

Sampling hole clip d=5.0 mm (0.19 inch) red Part no.: 908337

Sampling hole clip d=5.5 mm (0.22 inch) red Part no.: 908338
The contents of this publication are subject to modifications without notice. All rights reserved.

Sampling hole clip d=6.0 mm (0.24 inch) red Part no.: 908339

Sampling hole clip d=6.5 mm (0.26 inch) red Part no.: 908340

Sampling hole clip d=7.0 mm (0.28 inch) red Part no.: 908341
313-840_001 / AI00_2015en

Sampling hole revision red Part no.: 908342

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 14
Product Sheet | Detecon

Aspirating smoke detectors


Aspiration tube system, mounting accessories

Adhesive: PVC glue Part no.: 905267

Technical specifications
Container 500 ml (0.13 gallone) can with brush
Weight 0.8 kg (1.76 lbs)

Adhesive: PVC glue NEW Part no.: 922714

Technical specifications
Container 125 ml (0.033 gallone) tube
Weight 0.2 kg (0.44 lbs)

PVC cleaner Part no.: 905269

Technical specifications
Container 1000 ml (0.26 gallone) funnel bottle
Weight 1.1 kg (2.42 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
313-850_001 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 15
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Pipe cutter plastic pipe + hose Part no.: 905281


For plastic pipes and hoses of 6 - 35 mm (0,23 to 1.38 inch)

Three-way ball valve, d=25 mm (0.98 inch) Part no.: 908548


For connecting compressed air to blow the sensor pipework
clean

Pipe blow-valve, PVC, automatic Part no.: 908721


Included in delivery
1 PVC sleeve d=40 mm (1.57 inch)
1 PVC reducer d=40/25 mm (1.57/0.98 inch)
1 Backflow preventer

Compressed-air connection for PVC-DWK Part no.: 908722


d=25 mm (0.98 inch) Included in delivery
1 PVC adapter sleeve
1 Brass reducing adapter
1 Compressed-air coupling

Sampling fitting set with heater, PVC, red Part no.: 908723
For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d = 5.7 mm (0.22 inch), colour coding: red

Sampling fitting set with heater, PVC, Part no.: 908724


The contents of this publication are subject to modifications without notice. All rights reserved.

yellow For creating the pipe system at temperatures down to


- 30°C (-11 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d = 5.9 mm (0.23 inch), colour coding: yellow

Sampling fitting set with heater, PVC, blue Part no.: 908725
For creating the pipe system at temperatures down to
- 30°C (-22 °F)
313-820_001 / AI00_2015en

Included in delivery
1 PVC T-piece including heating resistor and
suction port d = 6.1 mm (0.24 inch), colour coding: blue

1/4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 16
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Sampling fitting set with heater, PVC, Part no.: 908726


green For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.3 mm (0.25 inch), colour coding: green

Sampling fitting set with heater, PVC, Part no.: 908727


white For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.5 mm (0.26 inch), colour coding: white

Sampling fitting set with heater, PVC, Part no.: 908728


black For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.7 mm (0.26 inch), colour coding: black

Sampling fitting set with heater, PVC, Part no.: 908729


violet For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.9 mm (0.27 inch), colour coding: violet

Sampling fitting set with heater, PVC, Part no.: 908730


brown For creating the pipe system at temperatures down to
- 30°C (-22 °F)

Included in delivery
1 PVC T-piece including heating resistor and
The contents of this publication are subject to modifications without notice. All rights reserved.

suction port d=7.1 mm (0.28 inch), colour coding: brown

Cable connector set, PVC Part no.: 908731


For creating the pipe system in refrigerated warehouses

Silicone wire, black Part no.: 908732


313-820_001 / AI00_2015en

For connecting the heaters, single-lead

Included in delivery
1 packaging unit with 100 m (3937 inch)

2/4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 17
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Silicone wire, white Part no.: 908733


For connecting the heaters, single-lead

Included in delivery
1 packaging unit with 100 m (3937 inch)

Filter box (small), d=25 mm (0.98 inch) Part no.: 908734


For use in rooms with low temperatures and high dust levels

Included in delivery
1 Filter box with built- in filter
2 Glands

Technical specifications
Enclosure PVC grey
Temperature range down to -30 °C (-22 °F)
80 x 82 x 85 mm (HxWxD)
Dimensions
3.2 x 3.2 x 0.8 inch (HxWxD)

Filter box (small) Part no.: 908740


For use in the filter box (small)

Technical specifications
Temperature range down to -30 °C (-22 °F)
80 x 80 x 20 mm (HxWxD)
Dimensions
3.2 x 3.2 x 0.8 inch (HxWxD)

Filter box (large) d=25 Part no.: 908735


For use in rooms with high dust levels
The contents of this publication are subject to modifications without notice. All rights reserved.

Included in delivery
1 Filter box with filter mat block, fine stage
2 Glands

Technical specifications
Enclosure PVC grey
Temperature range normal
120 x 122 x 85 mm (HxWxD)
Dimensions
4.7 x 4.8 x 3.4 inch (HxWxD)
313-820_001 / AI00_2015en

3/4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 18
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Filter mat block fine stage Part no.: 908741


For use in the filter box (large)

Technical specifications
Temperature range normal
117 x 80 x 80 mm (HxWxD)
Dimensions
4.6 x 3.2 x 3.2 inch (HxWxD)

Filter active detector Part no.: 900341


Air filter for use in Minimax aspirating fire detection systems
in case of polluted ambient air.

Spare parts
Replacement kit filter active detector 902471
consisting of 1 coarse filter mat, 1 fine filter and
1 Infusion filter 5 µm (for AMX detectors only)

Technical specifications
Enclosure Polycarbonate, RAL 7035 - light grey
-5 °C to +65 °C
Temperature range
(+23 °F to +149 °F)
Relative humidity max. 98 %, condensation on the
(IEC 721-3-3) filter mats must be ruled out
IP rating (EN 60529) IP 65
Weight 370 g (0.8 lbs)
122 x 190 x 85 mm (HxWxD)
Dimensions
4.8 x 7.5 x 3.4 inch (HxWxD)

Part no.: 908736


Dust trap box d=25 mm (0.98 inch)
For use in rooms with high dust levels

Included in delivery
1 Dust trap
2 Glands
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Enclosure PVC grey
240 x 250 x 90 mm (HxWxD)
Dimensions
9.5 x 9.8 x 3.5 inch (HxWxD)
313-820_001 / AI00_2015en

4/4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 19
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Dust separator, cyklone d=25 mm Part no.: 908737


(0.98 inch) For use in rooms with high dust levels. Smoke and
water separator for aspirating smoke detectors.
Filterless separation of granular foreign matter with a
particle size exceeding 100 μ or liquid aerosols.

Included in delivery
1 Dust and cyclone separator with adapters for installation in
sensor pipe systems d = 25 mm (0.98 inch)

Technical specifications
Enclosure PVC grey

Automatic blow-out device ADB 01A Part no.: 908700


For aspirating smoke detectors for use in rooms with very
high dust levels. For the automatic cleaning (blowing out) of
the sensor pipe system using compressed air.

Technical specifications
Operating voltage 15 - 30 V DC
Compressed-air port Constant, approx. 4 bar

Water retaining box, standard Part no.: 908738


For use with aspirating smoke detectors in rooms with
high humidity

Included in delivery
1 Water retaining box, standard
1 Gland
1 T-piece for connection to the sensor pipe
d = 25 mm (0.98 inch)

Technical specifications
The contents of this publication are subject to modifications without notice. All rights reserved.

Enclosure PVC grey


390 x 250 x 90 mm (HxWxD)
Dimensions
15.4 x 9.8 x 3.5 inch (HxWxD)
313-820_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 20
Product Sheet | Detecon

Aspirating smoke detectors


Fittings

Detonation flame arrester Part no.: 908739


For detection in hazard areas zone 1 (category 2G)
and zone 2 (category 3G) in accordance with the
Directive 94/9/EC (ATEX 100a). BAM and TÜV-certified
(TÜV = German Inspection Authority) and approved for
products of explosion group IIC, up to a permissible standard
gap width of >= 0.29 mm (1.14 inch). The aspirating smoke
detector needs to be mounted outside the potentially
explosive area.

Included in delivery
1 Explosion and detonation arrester
2 Glands

Technical specifications
Enclosure PVC grey
390 x 250 x 90 mm (HxWxD)
Dimensions
15.4 x 9.8 x 3.5 inch (HxWxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
313-820_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 21
Product Sheet | Detecon

Aspirating smoke detectors


OneU®

OneU® active extinguishing system Part no.: 915948


The OneU® active extinguishing system, which is
intended for installation in closed switch cabinet systems,
is a stand-alone, compact unit that is able to detect and
extinguish fires. NovecTM 1230 by 3MTM is used as the
extinguishing agent which vaporizes at the discharge
nozzle and spreads evenly across the extinguishing zone.
This extinguishes the fire by extracting heat energy from the
flames. Fire detection occurs by means of 2 fire detectors.
Alarms and failures can be transmitted to a superordinate
position (monitoring and/or control equipment) via
potential-free contacts or via the Monitoring System
CMC III (a Rittal product).
The compact system with a space requirement of only
Product features 1 height unit is intended for installation in the upper third
• Compact and space-efficient design of the closed switch cabinet system to be protected.
• Fire detection and fire fighting by one device
directly on and in the protected site
• Expandable by networking with slave extinguishing
Application / Function
modules for protecting up to four other sites The ideal area of application for the OneU® are spaces
with a self-contained atmosphere, as found in server,
• Residue-free extinguishing agent network, modem and IT cabinets, modem and machine
Novec™ 1230 from 3M™ control cabinets, high- and low-voltage cabinets, and
• Minimal maintenance required telephone distribution cabinets. The smoke aspiration
system takes air samples from the entire cabinet volume
and conveys them past the two sensitive smoke detectors.
Technical specifications When the pre-alarm threshold is reached, shutdown
measures can be initiated. If the smoke concentration
Detection method 2 optical smoke detectors continues to rise, the extinguishant container is triggered
Rated voltage 100 - 240 V AC, 50/60 Hz by the fire alarm threshold. The extinguishing agent is
Emergency power supply approx. 4 h
discharged, gasified at the discharge nozzle and distributed
effectively in the cabinet.
IP rating IP 30
+10 °C to +40 °C (Operating)
Ambient temperature +50 °F to +104 °F (Operating)
Included in delivery
with batteries -20 °C to +65 °C (Storage) OneU® active extinguishing system 915948
-4 °F to +149 °F (Storage)
Humidity up to 96 %, no condensation Not included in delivery
4 dry changeover contacts Aspiration tube system 907061
Ports Pre-alarm, fire, extinguishing,
group fault, for 24 V 0.5 A
Optional accessories
1 LCD with text display
The contents of this publication are subject to modifications without notice. All rights reserved.

1 LED green „Operation“ OneU® ED extinguishing system 915949


1 LED yellow „Shutdown“ LMC III Monitoring system (Rittal)
1 LED red „Extinguishing System SNMP V3
Display features acc.
system triggered“
DIN 14497
1 LED red „Extinguishing
system released“ Note
1 LED yellow „Blocked“ Door contact switches 889337 with retainers
1 LED yellow „ Failure“ are to be provided by the customer.
Aspiration tube Plug-in system 22 mm (0.86 inch) OneU® can perform fire detection monitoring
for up to five server cabinets, but not selectively.
approx. +/- 10 % volumetic flow
Airflow monitoring One OneU® active extinguishing system can
rate, adjustable
control up to 4 more extinguishing modules.
Extinguishing agent approx. 1.8 l NovecTM 1230
250-111_001 / AI00_2015en

Protected volume
max. 2.8 m3 (33 lbs) Approvals / marking
Cabinet volume
approx. 15.5 kg (34.2 lbs) S 614001
Weight
with extinguishing agent
Enclosure dimensions 19“, 1 U, 660 mm (26 inch) deep

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 22
Product Sheet | Detecon

Aspirating smoke detectors


OneU®

OneU® DD aspirating smoke detection Part no.: 915947


system The OneU® DD aspirating smoke detection system,
which is intended for installation in closed switch cabinet
systems, is a stand-alone, compact unit that is able to
detect fires. Alarms and failures can be transmitted to a
superordinate position (monitoring and/or control equipment)
via potential-free contacts or via the Monitoring System
CMC III (a Rittal product).
The compact system with a space requirement of only
1 height unit is intended for installation in the upper third of
the closed switch cabinet system to be protected.

Application / Function
Product features The ideal area of application for the OneU® are spaces
• Compact and space-efficient design with a self-contained atmosphere, as found in server,
• Fire detection directly on and in the protected site network, modem and IT cabinets, modem and machine
control cabinets, high- and low-voltage cabinets, and
• Expandable by networking with OneU® ED
telephone distribution cabinets. The smoke aspiration
(slave extinguishing system) for protecting
system takes air samples from the entire cabinet volume
up to four other sites
and conveys them past the two sensitive smoke detectors.
• Easy to mount due to use of international When the pre-alarm threshold is reached, shutdown
standard 19” technology measures can be initiated. If the smoke concentration
• Minimal maintenance required continues to rise, the extinguishant container is triggered
by the fire alarm threshold. The extinguishing agent is
discharged, gasified at the discharge nozzle and distributed
effectively in the cabinet.
Technical specifications
Detection method 2 optical smoke detectors Included in delivery
Rated voltage 100 - 240 V AC, 50/60 Hz OneU® DD aspirating smoke detection system 915947
Operating voltage 24 V DC
Emergency power supply approx. 4 h Not included in delivery
IP rating IP 30 Aspiration tube system 907061

+10 °C to +40 °C (Operating)


Ambient temperature +50 °F to +104 °F (Operating) Optional accessories
with batteries -20 °C to +65 °C (Storage) OneU® ED extinguishing system 915949
-4 °F to +149 °F (Storage) LMC III Monitoring system (Rittal)
Humidity up to 96 %, no condensation System SNMP V3
4 dry changeover contacts
Ports Pre-alarm, fire, extinguishing, Note
The contents of this publication are subject to modifications without notice. All rights reserved.

group fault, for 24 V 0.5 A


Door contact switches 889337 with retainers
1 LCD with text display are to be provided by the customer.
1 LED green „Operation“ OneU can perform fire detection monitoring
1 LED yellow „Shutdown“
for up to five server cabinets, but not selectively.
1 LED red „Extinguishing
Display features acc. One OneU® DD can control up to 5 OneU® ED modules.
system triggered“
DIN 14497
1 LED red „Extinguishing
system released“ Approvals / marking
1 LED yellow „Blocked“
1 LED yellow „ Failure“
S 614001
Aspiration tube Plug-in system 22 mm (0.86 inch)
approx. +/- 10 %
Air flow monitoring
of the total air flow current
250-111_002 / AI00_2015en

Weight approx. 9.6 kg (21.2 lbs)


Enclosure dimensions 19“, 1 U, 490 mm (19.3 inch) deep

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 7 - 23
Product Sheet | Detecon

Aspirating smoke detectors


OneU®

OneU® ED extinguishing system Part no.: 915949


The OneU® ED extinguishing system, which is intended
for installation in closed switch cabinet systems, is a compact
unit that is able to extinguish fires. A superordinate system
(Active extinguishing system OneU® or aspirating smoke
detection system OneU® DD) is to be in place in order to
activate this unit. NovecTM 1230 by 3MTM is used as the
extinguishing agent which vaporizes at the discharge
nozzle and spreads evenly across the extinguishing zone.
This extinguishes the fire by extracting heat energy from
the flames. Alarms and failures can be transmitted to a
superordinate position (monitoring and/or control equipment)
via potential-free contacts or via the Monitoring System
CMC III (a Rittal product).
Product features The compact system with a space requirement of only
• Compact and space-efficient design 1 heigt unit is intended for installation in the upper third
• Fire detection directly on and in the protected site of the closed switch cabinet system to be protected.
• Can be expanded by networking with
up to 4 OneU® ED extinguishing systems Application / Function
• Easy to mount due to use of The OneU® ED is part of the OneU® fire protection
international standard 19” technology device series, acting as an additional extinguishing system
• Minimal maintenance required for expanding the extinguishing capacity by 2.8 m³
(98.9 cubic foot). Smoke detection is always performed by
the master device.

Technical specifications
Included in delivery
approx. 1.8 l (0.48 gallone) OneU® ED extinguishing system 915949
Extinguishing agent
NovecTM 1230
Rated voltage 24 V DC
Optional accessories
Operating voltage 24 V DC -3/+5 V
OneU® active extinguishing system 915948
Emergency power supply approx. 4 h via master device OneU® DD aspirating smoke detection system 915947
IP rating IP 30 LMC III Monitoring system (Rittal)
+10 °C to +35 °C (Operating)
System SNMP V3
Ambient temperature +50 °F to +95 °F (Operating)
with batteries -20 °C to +65 °C (Storage) Note
-4 °F to +149 °F (Storage)
Door contact switches 889337 with retainers
Humidity up to 96 %, no condensation are to be provided by the customer.
4 dry changeover contacts The OneU® ED can only be operated together with a OneU®
Ports Pre-alarm, fire, extinguishing, active extinguishing system or a OneU® DD, see manual.
group fault, for 24 V 1 A
The contents of this publication are subject to modifications without notice. All rights reserved.

exclusive via master divce Approvals / marking


Display features
(OneU® or OneU® DD)
Fire detection via master device S 614001
Actuation extinguishing
via master device
system
max. 2.8 m3 (33 lbs)
Protected volume
Cabinet volume
approx. 12.5 kg (27.6 lbs)
Weight
with extinguishing agent
Enclosure dimensions 19“, 1 U, 660 mm (26 inch) deep
250-111_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 1 - 24
Product Sheet | Detecon

Special detectors
Linear smoke detectors

FireRay 5000 Part no.: 908458


The FireRay 5000 is a motorised, linear smoke detector
with automatic alignment and optical rays. The FireRay
5000 consists of an infrared transmitter and an infrared
receiver within the same device. It functions by conducting
a clearly distinguished ray to a reflective prism. If the ray
meets smoke, a decrease in performance is recorded and
an alarm signal is triggered soon as this drops below a
pre-programmed limit value. As soon as the laser is used to
roughly align the ray, the Auto-Align takes over to move the
ray into the optimal position. This is an ideal solution for
the protection of wide areas in which the use of standard
Product features detector technology would pose significant costs.
• Integrated laser
• One system controller unit can be used to control
and monitor up to two detector heads
• Monitored area min. 8 m (315 inch) to max. 100 m
(3937 inch) depends on the used number of prism reflectors
• Auto-Align: automatic ray alignment
• Auto-Optimise: adjustment to compensate
for building movement and impurities
• 2-wire interface between system control device and detector
• Integrated event log for 50 events per detector head

Included in delivery
Technical specifications 1 System controller unit
1 Detector head
Optical wavelength 850 nm 1 Reflector
-10 °C to +55 °C
Ambient temperature
(+14 °F to +131 °F)
- 40 °C to + 85 °C Approvals / marking
Storage temperature
(- 40 °F to +185 °F)
max. 93 %, G 208017 0832-CPD-0565
Relative humidity
no condensation
Operating voltage 14 - 36 V DC
Rated voltage 24 V DC
Rated current consumption
5 - 6 mA
with 1 detector head
Rated current consumption
7.5 - 8.5 mA
with 2 detector heads
Current consumption
The contents of this publication are subject to modifications without notice. All rights reserved.

35 - 37 mA
alignment mode
2 alarm relays
Outputs
2 fault relays
Relay contact voltage 30 V DC
Relay contact current 100 mA
Response sensitivity adjustable 10 - 60 %
IP rating IP 54
Specification according to EN 54-12
Weight (system control) 1000 g (2.2 lbs)
Dimensions 202 x 230 x 87 mm (WxHxD)
(system control) 7.95 x 9.05 x 3.42 inch (WxHxD)
314-101_001 / AI01_2016en

Weight (detector head) 500 g (1.1 lbs)


134 x 131 x 134 mm (WxHxD)
Dimensions detector head
5.27 x 5.16 x 5.27 inch (WxHxD)
100 x 100 x 10 mm (WxHxD)
Dimensions prism reflectors
3.9 x 3.9 x 0.4 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 1
Product Sheet | Detecon

Special detectors
Linear smoke detectors, accessories

Universal mounting bracket Part no.: 908460


Bracket pivots for accurate alignment of FireRay 5000
smoke detector or reflector

Technical specifications
Weight 200 g (0.4 lbs)
135 x 135 x 71 mm (WxHxD)
Dimensions
5.3 x 5.3 x 2.8 inch (WxHxD)

Long range reflector kit (3 prisms) Part no.: 908459


3 additional reflectors for use when the installation is between
50 and 100 m (1968 and 3937 inch) from detector head

Technical specifications
Weight (1 reflector) 100 g (0.2 lbs)
100 x 100 x 10 mm (WxHxD)
Dimensions (1 reflector)
3.9 x 3.9 x 0.4 inch (WxHxD)

Detector head Part no.: 908661


Additional detector head with reflector for the FireRay 5000

Obscuration filter Part no.: 908461


Obscuration test filter to perform the sensitivity test
The contents of this publication are subject to modifications without notice. All rights reserved.

Single reflector alignment adapter Part no.: 908662


Comes pre-drilled to mount 1 reflector.
Designed to mount on the universal mounting bracket
314-104_001 / AI01_2015en

Not included in delivery


Universal holder and reflector

1/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 2
Product Sheet | Detecon

Special detectors
Linear smoke detectors, accessories

4 reflectors alignment adapter Part no.: 908663


Comes pre-drilled to mount 4 reflectors.
Designed to mount on the universal mounting bracket

Not included in delivery


Universal holder and reflectors

Reflector wall bracket Part no.: 908664


Comes pre-drilled to mount (1 up to 50 m (1968 inch))
or 4 (from 50 m (1968 inch) to 100 m (3937 inch)) reflectors.
Hole pattern on side mounting flange similar to unistrut.

System controller back box Part no.: 908665


Includes conduit knock-outs on top and bottom.
Surface or flush mount. Will mount to single gang,
double gang or 4 square box.

Note
Is intended for use on the US market

System controller semi flush trim plate Part no.: 908666


Mounts on system controller back box for semi flush
installation

Note
The contents of this publication are subject to modifications without notice. All rights reserved.

Is intended for use on the US market

Detector head back box Part no.: 908667


Back box includes knock-outs on all four sides.
Will mount over single gang, double gang or 4 square box.

Note
314-104_001 / AI01_2015en

Is intended for use on the US market

2/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 3
Product Sheet | Detecon

Special detectors
Linear smoke detectors, accessories

Detector head cover plate Part no.: 908668


Use with detector head back box. Pre-drilled to mount the
detector head

Not included in delivery


Flush-mounted enclosure for detector

Note
Is intended for use on the US market

Ceiling pendant mount bracket Part no.: 908669


Comes pre-drilled to mount detector head.
Can be used for single or bidirectional applications.
Includes 2 mounting plates and 1 blank cover.
The contents of this publication are subject to modifications without notice. All rights reserved.
314-104_001 / AI01_2015en

3/3
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 4
Product Sheet | Detecon

Special detectors
Cyklone monitoring

VMX 3001-S Part no.: 903121


VMX 3001-E Part no.: 903122
In the timber industry and in milling plants, especially
in the chipboard industry, frequent clogging of cyclones
occurs due to material deposits which result in a sudden
emission of material on the clean air side. In order to
detect this material accumulation in the initial stage, thus
preventing breakdowns and pollutant emissions, special
sensors are installed in the conical section of the cyclone.
Monitoring occurs according to the light barrier principle
with one infrared emitter VMX 3001-S and on the opposite
side one receiver VMX 3001-E.

Product features Not included in delivery


• Unproblematic alignment of the detectors Support ball mounting 903123
by means of a spherical joint Fitting tool 843774
Support adapter assembly with washer 891848
Support adapter assembly with washer
250 °C (482 °F) 800034
Technical specifications Air flushing single hole 907822
Infrared light barrier according to
Detection method
the transmitted light method Connection / mounting
Viewing angle 60 ° in case of air flushing Connection cable standard detector 2-wire
Spectral sensitivity 950 nm Conductor cross-section max. 2.5 mm2 (AWG 13)
Recommended cable with shielding braid 606061
24 V DC (VMX 3001-S)
Operating voltage LIYCY grey, 5x0.5 mm2 (AWG 20)
7.6-13.2 V DC (VMX 3001-E)
Cable gland M16x1.5, brass galv. nickel-plated, EMV
25 mA (VMX 3001-S)
Alarm current consumption
approx. 18 mA (VMX 3001-E)
Alarm indication 1 LED red
Approvals / marking
Electrostatic shielding required
G 208191
-20 °C to +70 °C
Operating temperature
(-4 °F to +158 °F)
IP rating (EN 60529) IP 65
Diecast aluminium,
Enclosure material
RAL 5009, blue
Relative humididy max. 95 % at 35 °C (+95 °F)
(IEC 721-3-3) no condensation
The contents of this publication are subject to modifications without notice. All rights reserved.

650 g (1.4 lbs) VMX 3001-S


Weight
900 g (2 lbs) VMX 3001-E
80 x 75 x 57 mm (WxHxD)
3.2 x 3 x 2.2 inch (WxHxD)
VMX 3001-S
Dimensions
125 x 80 x 57 mm (WxHxD)
4.9 x 3.2 x 2.2 inch (WxHxD)
VMX 3001-E
314-801_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 5
Product Sheet | Detecon

Special detectors
Cyklone monitoring, Ex

VMX 3001-S Ex Dust Part no.: 907434


VMX 3001-E Ex Dust Part no.: 907433
In the timber industry and in milling plants, especially
in the chipboard industry, frequent clogging of cyclones
occurs due to material deposits which result in a sudden
emission of material on the clean air side. In order to
detect this material accumulation in the initial stage, thus
preventing breakdowns and pollutant emissions, special
sensors are installed in the conical section of the cyclone.
These detector versions are suitable as category 1D/3D
devices for use in areas of the zones 20, 21 and 22 where
there is risk of dust explosion.

Product features Not included in delivery


• Easy alignment of the detectors Support ball mounting 903123
by means of a spherical joint Fitting tool 843774
Support adapter assembly with washer 891848
Support adapter assembly with washer
250 °C (482 °F) 800034
Technical specifications Air flushing single hole 907822
Infrared light barrier according to
Detection method
the transmitted light method Connection / mounting
Viewing angle 60 ° in case of air flushing Connecting cable standard detector 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
Spectral sensitivity 950 nm
Recommended cable with shielding braid 606061
24 V DC (VMX 3001-S) LIYCY grey, 5x0.5 mm2 (AWG 20)
Operating voltage
7,6-13,2 V DC (VMX 3001-E) Cable gland M16x1.5, brass galv. nickel-plated, EMV, Ex
25 mA (VMX 3001-S)
Alarm current consumption
approx. 18 mA (VMX 3001-E)
Approvals / marking
Alarm indication 1 LED red
Ex conformity in acc. with 94/9/EG:
Electrostatic shielding required x II 1/3D Ex tD A20/22 IP 65 T100°C (-E)
Operating temperature
-20 °C to +70 °C x II 1/3D Ex tD A20/22 IP 65 T136°C (-S)
(-4 °F to +158 °F) Type examination certificate: BVS 09 ATEX E025
IP rating (EN 60529) IP 65
Diecast aluminium, G 208191
Enclosure material
RAL 5009, blue
Relative humididy max. 95 % at 35 °C (+95 °F)
(IEC 721-3-3) no condensation
The contents of this publication are subject to modifications without notice. All rights reserved.

650 g (1.4 lbs) VMX 3001-S


Weight
900 g (2 lbs) VMX 3001-E
80 x 75 x 57 mm (WxHxD)
3.2 x 3 x 2.2 inch (WxHxD)
VMX 3001-S
Dimensions
125 x 80 x 57 mm (WxHxD)
4.9 x 3.2 x 2.2 inch (WxHxD)
VMX 3001-E
314-802_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 8 - 6
Product Sheet | Detecon

Notification devices
Audible

Sounder ROLP MX Part no.: 908631


Audible notification device for signalling fire hazards,
approved according EN 54-3 and VdS. The alarm signalling
device offers a selection of 32 tones and the configuration
is carried out via a five-pin DIP switch. Up to two different
acoustic signals can be configured via wiring. The volume
can be adjusted via a DIP-switch.

Technical specifications Included in delivery


1 Sounder ROLP MX
Enclosure material ABS, red
IP rating IP 65
Not included in delivery
Rated voltage 24 V DC
Mounting hardware
Operating voltage 9 V - 28 V DC Cable glands
Rated current consumption 32 mA
Tones 32 Connection / mounting
Tone stages 2 Recommended cable 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
-25 °C to +70 °C
Ambient temperature
(-13 °F to +158 °F)
Relative humididy max. 95 % Note
The sounder can be operated via the voltage increase
Sound pressure up to 102 dB (A) 1 m
function as well as via the voltage reversal function at the
Weight 250 g (0.6 lbs) FMZ 5000 and FMZ 5000 mod S control panels. The device
93 x 93 mm (WxH) has an integrated reverse polarity protection diode.
Dimensions
3.7 x 3.7 inch (WxH)
Approvals / marking

G 206019 0832-CPD-0128
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 1
Product Sheet | Detecon

Notification devices
Audible

Sounder YO4 MX Part no.: 893559


Audible notification device for signalling fire hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Technical specifications Included in delivery


1 Sounder YO4 MX
Enclosure material ABS, red
IP rating IP 54
Not included in delivery
-25 °C to +55 °C
Ambient temperature Mounting hardware
(-13 °F to +131 °F)
Cable glands
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F)
Relative humidity max. 90 %
Connection / mounting
Recommended cable 2-wire
Rated voltage 24 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 18 V - 30 V DC
Rated current consumption 110 mA Note
Duty cycle 100 % The sounder can be operated via the voltage increase
Tones 32 function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
Sound pressure up to 106 dB (A) 1 m has an integrated reverse polarity protection diode.
approx. 1300 m2
Sound range (13993 square foot),
Ø 40 m (1575 inch)
Approvals / marking
Weight 240 g (0.5 lbs)
G 209134 0086-CPD-96705
88 x 88 x 81 mm (WxHxD)
Dimensions
3.5 x 3.5 x 3.2 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 2
Product Sheet | Detecon

Notification devices
Audible

Sounder YO5 MX Part no.: 893547


Audible notification device for signalling fire hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Technical specifications Included in delivery


1 Sounder YO5 MX
Enclosure material ABS, red
IP rating IP 54
Not included in delivery
-25 °C to +55 °C Mounting hardware
Ambient temperature
(-13 °F to +131 °F)
Cable glands
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F)
Connection / mounting
Relative humidity max. 90 %
Recommended cable 2-wire
Rated voltage 24 V DC Conductor cross-section max. 1.5 mm2 (AWG 13)
Operating voltage 18 V - 30 V DC
Rated current consumption 90 mA Note
Duty cycle 100 % The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
Tones 32 FMZ 5000 and FMZ 5000 mod S control panels. The device
Sound pressure up to 110 dB (A) 1 m has an integrated reverse polarity protection diode.
approx. 1300 m2
Sound range (13993 square foot), Approvals / marking
Ø 40 m (1575 inch)
Weight 710 g (1.6 lbs) G 209134 0086-CPD-96705
134 x 134 x 128 mm (WxHxD)
Dimensions
5.3 x 5.3 x 5.6 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 3
Product Sheet | Detecon

Notification devices
Audible

Sounder PA 1 Part no.: 917456


Audible notification device for signaling fire hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes, simple electrical connection on the
bottom of the casing. A potentiometer can be used to adjust
the volume.

Technical specifications Included in delivery


1 Sounder PA 1
Enclosure material PC/ABS Blend, red
IP rating IP 66
Not included in delivery
-40 °C to +55 °C
Ambient temperature Mounting hardware
(-40 °F to +131 °F)
Cable glands
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F)
Relative humidity max. 90 %
Connection / mounting
Recommended cable 2-wire
Rated voltage 24 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 10 V - 57 V DC
Rated current consumption at 24 V DC 50 mA Note
Tones 80 The sounder has three pre-cut M20 cable openings.
Tone stages 3 additional externally selectable It can only be operated via the voltage reversal function
at the FMZ 5000 and FMZ 5000 mod S control panels. The
Sound pressure up to 100 dB (A) 1 m device has an integrated reverse polarity protection diode.
Weight 270 g (0.59 lbs)
109.5 x 86 x 80.6 mm (WxHxD) Approvals / marking
Dimensions
4.3 x 3.4 x 3.2 inch (WxHxD)
G 212115 0786-CPD-21182
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 4
Product Sheet | Detecon

Notification devices
Audible

Sounder PA 5 Part no.: 917457


Audible notification device for signaling fire hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes, simple electrical connection on the
bottom of the casing. A potentiometer can be used to adjust
the volume.

Technical specifications Included in delivery


1 Sounder PA 5
Enclosure material PC/ABS Blend, red
IP rating IP 66
Not included in delivery
-40 °C to +55 °C
Ambient temperature Mounting hardware
(-40 °F to +131 °F)
Cable glands
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F)
Relative humidity max. 90 %
Connection / mounting
Recommended cable 2-wire
Rated voltage 24 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 10 V - 57 V DC
Rated current consumption at 24 V DC 50 mA Note
Tones 80 The sounder has three pre-cut M20 cable openings. It can
Tone stages 3 additional externally selectable only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
Sound pressure up to 105 dB (A) 1 m has an integrated reverse polarity protection diode.
Weight 643 g (1.41 lbs)
143 x 135 x 132 mm (WxHxD) Approvals / marking
Dimensions
5.6 x 5.3 x 5.2 inch (WxHxD)
G 212115 0786-CPD-21182
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_005 / AI01_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 5
Product Sheet | Detecon

Notification devices
Audible

Sounder A105N Part no.: 917458


Audible notification device for signaling fire hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes. A potentiometer can be used to adjust
the volume.

Technical specifications Included in delivery


1 Sounder A105N
Enclosure material ABS, red
2 Blanking plugs M 20
IP rating IP 66
-25 °C to +55 °C Not included in delivery
Ambient temperature
(-13 °F to +131 °F)
Mounting hardware
-40 °C to +70 °C Cable glands
Storage temperature
(-40 °F to +158 °F)
Relative humidity at 20 °C max. 90 %
Connection / mounting
Rated voltage 24 V DC Recommended cable 2-wire
Operating voltage 10 V - 30 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Rated current consumption at 24 V DC 25 mA
Tones 32 Note
Tone stages 3 The sounder has two M20 cable openings. It can only be
operated via the voltage reversal function at the FMZ 5000
Sound pressure up to 112 dB (A) 1 m and FMZ 5000 mod S control panels. The device has
Weight 750 g (1.65 lbs) an integrated reverse polarity protection diode.
144 x 130 x 133.5 mm (WxHxD)
Dimensions
5.7 x 5.1 x 5.2 inch (WxHxD) Approvals / marking

G 205121 0786-CPD-20257
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 6
Product Sheet | Detecon

Notification devices
Audible

Sounder Symphoni HO WP Part no.: 917459


Audible notification device for signaling fire hazards,
approved according EN 54-3 and VdS.
A potentiometer can be used to adjust the volume.

Technical specifications Included in delivery


1 Sounder Symphoni HO WP
Enclosure material ABS, red
IP rating IP 66
Not included in delivery
-25 °C to +70 °C
Ambient temperature Mounting hardware
(-13 °F to +158 °F)
Cable glands
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F)
Relative humidity max. 90 %
Connection / mounting
Recommended cable 2-wire
Rated voltage 24 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 18 V - 28 V DC
Rated current consumption 260 mA Note
Tones 32 The sounder can only be operated via the voltage reversal
Tone stages 2 function at the FMZ 5000 and FMZ 5000 mod S control
panels. The device has an integrated reverse polarity
Sound pressure up to 120 dB (A) 1 m protection diode.
Weight 680 g (1.5 lbs)
110 x 110 x 105 mm (WxHxD) Approvals / marking
Dimensions
4.3 x 4.3 x 4.1 inch (WxHxD)
G 206027 0832-CPD-0142
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_007 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 7
Product Sheet | Detecon

Notification devices
Audible

Sounder DS10 MX Part no.: 801175


Audible notification device for signalling fire hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Technical specifications Included in delivery


1 Sounder DS10 MX
Enclosure material Diecast aluminium, red
1 Cable gland M20 x 1.5
IP rating IP 67 1 Blanking plug M20
-25 °C to +55 °C
Ambient temperature
(-13 °F to +131 °F)
Not included in delivery
-40 °C to +70 °C Mounting hardware
Storage temperature
(-40 °F to +158 °F)
Relative humidity max. 90 %
Connection / mounting
Rated voltage 24 V DC Recommended cable 2-wire
Operating voltage 19 V - 29 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Rated current consumption approx. 420 mA
Duty cycle 100 % Note
Tones 32 The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
Sound pressure up to 110 dB (A) 1 m FMZ 5000 and FMZ 5000 mod S control panels. The device
Sound range
approx. 10000 m2 (6.2 miles), has an integrated reverse polarity protection diode.
Ø 116 m (4567 inch)
Weight 2200 g (4.9 lbs)
Approvals / marking
134 x 134 x 143 mm (WxHxD)
Dimensions
5.3 x 5.3 x 5.6 inch (WxHxD)
G 204031 0786-CPD-20005
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 8
Product Sheet | Detecon

Notification devices
Audible

Sounder DS10 MX ext. tone selection Part no.: 801176


Audible notification device for signalling fire hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Product features Included in delivery


• Sounder with external tone selection 1 Sounder DS10 MX ext. tone selection
1 Cable gland M20 x 1.5
1 Blanking plug M20

Technical specifications
Not included in delivery
Enclosure material Diecast aluminium, red Mounting hardware
IP rating IP 67
-25 °C to +55 °C Connection / mounting
Ambient temperature
(-13 °F to +131 °F) Recommended cable 2-wire
-40 °C to +70 °C with function „ext. tone sel.2 3-wire
Storage temperature
(-40 °F to +158 °F) Conductor cross-section max. 2.5 mm2 (AWG 13)
Relative humidity max. 90 %
Rated voltage 24 V DC Note
Operating voltage 19 V - 29 V DC The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
Rated current consumption approx. 420 mA
FMZ 5000 and FMZ 5000 mod S control panels. The device
Duty cycle 100 % has an integrated reverse polarity protection diode
Tones 32
Sound pressure up to 110 dB (A) 1 m Approvals / marking
approx. 10000 m2 (6.2 miles),
Sound range
Ø 116 m (4567 inch) G 204031 0786-CPD-20005
Weight 2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions
5.3 x 5.3 x 5.6 inch (WxHxD)
320-110_009 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 9
Product Sheet | Detecon

Notification devices
Audible

Sounder HR NEW Part no.: 918424


Audible notification device for signalling fire hazards.
This sounder is listed for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable from tone and volume via rotary switch 1 Sounder HR
• For indoor use
Not included in delivery
Back box
Mounting hardware
Technical specifications
Enclosure material PC/ABS Blend, red Connecting / mounting
Rated voltage 24 V DC Recommended cable 2-wire
Operating voltage 8 - 33 V DC Conductor cross-section  max. 3.3 mm² (AWG12)
approx. 70 mA
Rated current consumption depending on sound Note
setting and candela Applicable for operation with the fire alarm panel
Tones 3 FMZ 5000 mod S CA (918493).
0°C to +49°C
Operating temperature
(+32 °F to +120.2 °F)
10 to 93%
Approvals / marking
Relative humidity
no condensation
Sound pressure up to 101 dB
Weight 205 g (0.5 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD) 
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 10
Product Sheet | Detecon

Notification devices
Audible

Sounder HRK NEW Part no.: 918425


Audible notification device for signalling fire hazards.
This sounder is listed for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable from tone and volume via rotary switch 1 Sounder HRK
1 Weatherproof back box
• For outdoor use

Not included in delivery


Mounting hardware
Technical specifications
Enclosure material PC, red Connecting / mounting
IP rating IP 56 Recommended cable 2-wire
IP rating Conductor cross-section  max. 3.3 mm² (AWG 12)
(American NEMA Standard Publ. 250)
NEMA 4X

Rated voltage 24 V DC Note


Operating voltage 8 - 33 V DC Applicable for operation with the fire alarm panel
approx. 70 mA FMZ 5000 mod S CA (918493).
Rated current consumption depending on sound
setting and candela
Tones 3 Approvals / marking
-40°C bis +66°C
Operating temperature
(-40 °F to +150.8 °F)
10 to 93%
Relative humidity
no condensation
Sound pressure up to 101 dB
Weight 460 g (1.0 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

119 x 142 x 33 mm (WxHxD) 


Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD) 
320-110_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 11
Product Sheet | Detecon

Notification devices
Audible, addressable

Loop sounder LSX 278r Part no.: 905805


Loop sounder for audible alarm notification, approved
according EN 54-3 in red colour. Addressing via built-in
DIP switches. Choice between two different tones,
controlled via the fire alarm panel.

Technical specifications Included in delivery


1 Loop sounder LSX 278r
Material PC
IP rating IP 21C
Not included in delivery
Sound pressure up to 100 dB
Mounting hardware
Colour red
Technology / protocol Loop AP / XP95 Connection / mounting
Integrated isolator no Cable recommendation standard
10 °C to +55 °C J-Y(St)Y -2x2x0.8 mm, red 747180
Ambient temperature Recommended cable 2-wire
(+14 °F to +131 °F)
Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 18 V - 28 V DC
Electrostatic shielding not required
Operating (alarm) current 5 mA
Quiescent current 330 µ A
Approvals / marking
Weight 290 g (0.6 lbs)
105 x 105 x 90 mm (WxHxD) 0832-CPD-0147
Dimensions
4.1 x 4.1 x 3.5 inch (WxHxD)

Loop sounder LSX 279W Part no.: 905806

Colour white
Otherwise like part no. 905805
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_010 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 12
Product Sheet | Detecon

Notification devices
Audible, addressable

Loop sounder LSX 274r WP Part no.: 905807


Loop sounder for audible alarm notification, approved
according EN 54-3 in red colour. Addressing via built-in DIP
switches. For applications in rough environmental conditions
with increased protection rating IP 66. Choice between two
different tones, controlled via the fire alarm panel.

Technical specifications Included in delivery


1 Loop sounder LSX 274r
Enclosure material PC, red
IP rating IP 66
Not included in delivery
Colour red
Mounting hardware
Technology / protocol Loop AP / XP95
Integrated isolator no Connection / mounting
-20 °C to +70 °C Cable recommendation standard
Ambient temperature
(-4 °F to +158 °F) J-Y(St)Y -2x2x0.8 mm, red 747180
Operating voltage 18 V - 28 V DC Recommended cable 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating (alarm) current 5 mA
Electrostatic shielding not required
Quiescent current 330 µA
Sound pressure up to 100 dB Approvals / marking
Weight 294 g (0.6 lbs)
110 x 110 x 113 mm (WxHxD) 0832-CPD-0147
Dimensions
4.3 x 4.3 x 4.5 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_011 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 13
Product Sheet | Detecon

Notification devices
Audible, addressable

Loop sounder LSX 001r Part no.: 916281


Loop sounder for audible alarm notification, approved
according EN 54-3 and VdS with an integrated dual isolator
in red colour. Addressing via built-in DIP switches.
Choice between two different tones, controlled via the
fire alarm panel.

Technical specifications Included in delivery


1 Loop sounder LSX 001r
Material PC
IP rating IP 65
Not included in delivery
Sound pressure up to 100 dB
Mounting hardware
Colour red
Technology / protocol Loop AP / XP95
Connection / mounting
Integrated isolator yes
Cable recommendation standard
Tones 3 J-Y(St)Y -2x2x0.8 mm, red 747180
-25 °C to +70 °C Recommended cable 2-wire
Ambient temperature
(-13 °F to +158 °F) Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 17 V - 28 V DC Electrostatic shielding not required
Operating (alarm) current 5 mA
Quiescent current 333 µA Approvals / marking
Weight 225 g (0.5 lbs)
97.5 x 104 mm (dia. x H) G 212187 0832-CPD-1050
Dimensions
3.8 x 4.1 inch (dia. x H)

Loop sounder LSX 002w Part no.: 916282


Colour white
Otherwise like part no. 916281
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_012 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 14
Product Sheet | Detecon

Notification devices
Audible, addressable

Base sounder BSX 300 Part no.: 901313


Base sounder for analogue addressable detectors for
acoustic alarm generation approved according EN 54-3 and
VdS with dual isolator, in white. Addressing via built-in DIP
switch. Simple mounting and easy insertion of detectors
by clockwork rotation with subsequent locking.
Cover available in red or white for use without detector.

Technical specifications Included in delivery


1 Base sounder BSX 300
Enclosure material white polycarbonate 1 Address card
Technology / protocol Loop AP / XP95
Integrated isolator yes Not included in delivery
IP rating IP 21D Cover red 912575
Cover white 912576
0 to 95 %
Relative humidity
no condensation
-20 °C to +60 °C Connection / mounting
Operating temperature
(-4 °F to +140 °F) Cable recommendation standard
Operating voltage 17 V - 28 V DC
J-Y(St)Y -2x2x0.8 mm, red 747180
Recommended cable 2-wire
Rated current consumption 200 µA Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating pressure 5 mA Electrostatic shielding not required
Sound pressure up to 91 dB
Weight 140 g (0.3 lbs)
Approvals / marking
115 x 38 mm (dia. x H)
Dimensions G 207009 0832-CPD-0373
4.5 x 1.5 inch (dia. x H)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-110_013 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 15
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder DS10 MX Ex Part no.: 900282


Audible notification device for the signaling of fire hazards,
approved according EN 54-3 and VdS. The sounder is
especially suitable for use in industrial environments with
hazard areas in zone 2 as well as 22. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Product features Included in delivery


• For use in Ex zones 2 and 22 1 Sounder DS10 MX Ex
1 Cable gland M20 x 1.5
1 Blanking plug M20

Technical specifications
Not included in delivery
Enclosure material Diecast aluminium, red Mounting hardware
IP rating IP 67
-25 °C to +55 °C (T4) Connection / mounting
-13 °F to +131 °F (T4)
Ambient temperature Recommended cable 2-wire
-25 °C to +60 °C (T3)
-13 °F to +140 °F (T3) Conductor cross-section max. 2.5 mm2 (AWG 13)
-40 °C to +70 °C
Storage temperature
-40 °F to +158 °F Note
Relative humidity max. 90 % The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
Rated voltage 24 V DC
FMZ 5000 and FMZ 5000 mod S control panels. The device
Operating voltage 19 V - 29 V DC has an integrated reverse polarity protection diode.
Rated current consumption 420 mA
Duty cycle 100 % Approvals / marking
Tones 32 Ex classification: x II 3G Ex nAc IIC T4 -25°C ≤ Ta ≤ +55°C
Sound pressure up to 110 dB (A) 1 m x II 3G Ex nAc IIC T3 -25°C ≤ Ta ≤ +60°C
approx. 10000 m2 x II 3D Ex tc IIIB T135°C IP 67 -25°C ≤ Ta ≤ +60°C
Sound range (107639 square foot),
Ø 116 m (4566 inch) Ex conformity Russia in acc. with TP TC 012/2011:
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 2200 g (4.9 lbs) 2Ex nAc IIC T3/T4


Ex tc IIIB T135°C IP 65
134 x 134 x 143 mm (WxHxD)
Dimensions
5.3 x 5.3 x 5.6 inch (WxHxD)
G 204031 0786-CPD-20005
320-120_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 16
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder DS10 MX Ex, ext. tone selection Part no.: 900283


Audible notification device for the signaling of fire hazards
approved according EN 54-3 and VdS. The sounder is
especially suitable for use in industrial environments with
hazard areas in zone 2 as well as 22. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.

Product features Included in delivery


• For use in Ex zones 2 and 22 1 Sounder DS10 MX Ex, ext. tone selection
• Sounder with external tone selection 1 Cable gland M20 x 1.5
1 Blanking plug M20

Not included in delivery


Technical specifications
Mounting hardware
Enclosure material Diecast aluminium, red
IP rating IP 67 Connection / mounting
-25 °C to +55 °C (T4) Recommended cable 2-wire
-13 °F to +131 °F (T4) with function „ext. tone sel.“ 3-wire
Ambient temperature
-25 °C to +60 °C (T3) Conductor cross-section max. 2.5 mm2 (AWG 13)
-13 °F to +140 °F (T3)
-40 °C to +70 °C
Storage temperature Note
-40 °F to +158 °F
The sounder can be operated via the voltage increase
Relative humidity max. 90 %
function as well as via the voltage reversal function at the
Rated voltage 24 V DC FMZ 5000 and FMZ 5000 mod S control panels. The device
Operating voltage 19 V - 29 V DC has an integrated reverse polarity protection diode.
Rated current consumption approx. 420 mA
Duty cycle 100 % Approvals / marking
Tones 32 Ex classification: x II 3G Ex nAc IIC T4 -25°C ≤ Ta ≤ +55°C
Sound pressure up to 110 dB (A) 1 m x II 3G Ex nAc IIC T3 -25°C ≤ Ta ≤ +60°C
x II 3D Ex tc IIIB T135°C IP 67 -25°C ≤ Ta ≤ +60°C
approx. 10000 m2
Sound range (107639 square foot),
The contents of this publication are subject to modifications without notice. All rights reserved.

Ø 116 m (4566 inch) G 204031 0786-CPD-20005


Weight 2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
Dimensions
5.3 x 5.3 x 5.6 inch (WxHxD)
320-120_002 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 17
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder BExS110E MX Part no.: 900876


Audible notification device for signalling fire hazards.
The sounder is especially suitable for use in industrial
environments with hazard areas in zone 1. Equipped with
an electronic module for operation directly on a primary
control group of the fire alarm panel via a voltage increase.

Product features Included in delivery


• Explosion-protected device for hazardous zone 1 1 Sounder BExS110E MX
• Sounder with flameproof enclosure
• Terminal compartment compliant with protection rating Not included in delivery
"Increased safety Ex e" Mounting hardware
Cable glands

Technical specifications Connection / mounting


Recommended cable 2-wire
Enclosure material Diecast aluminium, red
Conductor cross-section max. 4 mm2 (AWG 11)
Horn material ABS, red
IP rating IP 67 Note
Ex de IIC T4 (-50 °C to +55 °C) The sounder can be operated via the voltage increase
(-58 °F to +131 °F) function as well as via the voltage reversal function at the
Ambient temperature
Ex de IIB T4 (-50 °C to +70 °C) FMZ 5000 and FMZ 5000 mod S control panels. The device
(-58 °F to +158 °F)
has an integrated reverse polarity protection diode.
-50 °C to +70 °C
Storage temperature
(-58 °F to +158 °F)
Relative humidity max. 90 %
Approvals / marking
Rated voltage 24 V DC Ex classification: x II 2G Ex de IIC T4
x II 2G Ex de IIB T4
Operating voltage 18 V - 30 V DC
Rated current consumption approx. 265 mA
Duty cycle 100 %
Tones 32
The contents of this publication are subject to modifications without notice. All rights reserved.

Sound pressure up to 107.5 dB (A) 1 m


approx. 5500 m2
Sound range (59201 square foot),
Ø 85 m (3346 inch)
Weight 3400 g (7.5 lbs)
181 x 275 mm (dia. x W)
Dimensions
7.1 x 10.8 inch (dia. x W)
320-120_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 18
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder BExS120E MX Part no.: 902254


Audible notification device for signalling fire hazards.
The sounder is especially suitable for use in industrial
environments with hazard areas in zone 1. Equipped with
an electronic module for operation directly on a primary
control group of the fire alarm panel via a voltage increase.

Product features Included in delivery


• Explosion-protected device for hazardous zone 1 1 Sounder BExS120E MX
• Sounder with flameproof enclosure
• Terminal compartment compliant with protection rating Not included in delivery
"Increased safety Ex e" Mounting hardware
Cable glands

Technical specifications Connection / mounting


Recommended cable 2-wire
Enclosure material Diecast aluminium, red
Conductor cross-section max. 4 mm2 (AWG 11)
Horn material ABS, red
IP rating IP 67
Note
Ex de IIC T4 (-50 °C to +55 °C) The sounder can be operated via the voltage increase
(-58 °F to +131 °F) function as well as via the voltage reversal function at the
Ambient temperature
Ex de IIB T4 (-50 °C to +70 °C)
FMZ 5000 and FMZ 5000 mod S control panels. The device
(-58 °F to +158 °F)
has an integrated reverse polarity protection diode.
-50 °C to +70 °C
Storage temperature
(-58 °F to +158 °F)
Relative humidity max. 90 %
Approvals / marking
Rated voltage 24 V DC
Ex classification: x II 2G Ex de IIC T4
x II 2G Ex de IIB T4
Operating voltage 18 V - 30 V DC
Rated current consumption approx. 900 mA
Duty cycle 100 %
Tones 32
The contents of this publication are subject to modifications without notice. All rights reserved.

Sound pressure up to115.2 dB (A) 1 m


approx. 30000 m2
Sound range (322917 square foot),
Ø 200 m (7874 inch)
Weight 3700 g (8.2 lbs)
220 x 326 mm (dia. x W)
Dimensions
8.7 x 12.8 inch (dia. x W)
320-120_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 19
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder YA90 MX Ex Part no.: 910654


Audible alarm device for signalling danger of fire that is
especially suitable for use in industrial environments with
hazard areas in zone 1 as well as 21. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.
The robust fibreglass-reinforced polyester (FRP) housing
is resistant to environmental effects and chemicals.

Product features Included in delivery


• Explosion-proof device for 1 Sounder YA90 MX Ex
hazardous zone 1 as well as 21 1 Dust cover
• High volume up to 115 dB (A) / 1 m (39 inch) 1 Blanking plug M20
• 32 standardised tone sequences selectable
• 2-stage alarm, independently selectable 2nd stage Not included in delivery
• Tone selection via 5-way DIL switch Mounting hardware

Connection / mounting
Technical specifications Recommended cable 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
Enclosure material Fibreglass-reinforced polyester, red
Horn material ABS, red
Note
IP rating IP 66 The sounder can be operated via the voltage increase
-60 °C to +60 °C function as well as via the voltage reversal function at the
Operating temperature
(-76 °F to +140 °F) FMZ 5000 and FMZ 5000 mod S control panels. The device
-60 °C to +70 °C has an integrated reverse polarity protection diode.
Storage temperature
(-76 °F to +158 °F)
Relative humidity max. 95 % Approvals / marking
Rated voltage 24 V DC Ex classification: x II 2G Ex d IIC T6 Ta -60°C to +60°C Gb
Operating voltage 18 V - 30 V DC x II 2D Ex tb IIIC T85°C Ta -60°C to +60°C Db IP 66
Rated current consumption 300 mA
Tones 32
The contents of this publication are subject to modifications without notice. All rights reserved.

Sound pressure up to 115 dB (A) 1 m


Weight 4500 g (9.9 lbs)
210 x 210 x 316 mm (WxHxD)
Dimensions
8.3 x 8.3 x 12.4 inch (WxHxD)
320-120_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 20
Product Sheet | Detecon

Notification devices
Audible, Ex

Sounder YA60 MX Ex Part no.: 910655


Audible alarm device for signalling danger of fire that is
especially suitable for use in industrial enviroments with
hazard areas in zone 1 as well as 21. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.
The robust aluminium housing is resistant to sea water,
environmental effects and chemicals.

Product features Included in delivery


• Explosion-proof device for 1 Sounder YA60 MX Ex
hazardous zone 1 as well as 21 1 Dust cover
• Max. 110 dB (A) / 1 m omnidirectional sound output 1 Blanking plug M20
• 32 standardised tone sequences selectable
• 2-stage alarm, independently selectable 2nd stage Not included in delivery
• Tone selection via DIL switch Mounting hardware

Connection / mounting
Recommended cable 2-wire
Technical specifications Conductor cross-section max. 2.5 mm2 (AWG 13)
Enclosure material Diecast aluminium, red
Horn material ABS, red Note
IP rating IP 66 The sounder can be operated via the voltage increase
-35 °C to +60 °C (T4 / T135°C)
function as well as via the voltage reversal function at the
(-31 °F to +140 °F (T4 / T135°C)) FMZ 5000 and FMZ 5000 mod S control panels. The device
Operating temperature has an integrated reverse polarity protection diode.
-35 °C to +40 °C (T6 / T85°C)
(-31 °F to +140 °F (T6 / T85°C))
-35 °C to +60 °C Approvals / marking
Storage temperature
(-31 °F to +140 °F)
Ex classification: x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
Relative humidity max. 95 %
x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
Rated voltage 24 V DC x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP 66
Operating voltage 18 V - 30 V DC x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP 66
Rated current consumption 350 mA
The contents of this publication are subject to modifications without notice. All rights reserved.

Tones 32
Sound pressure up to 110 dB (A) 1 m
Weight 5400 g (11.9 lbs)
288 x 145 mm (HxD)
Dimensions
11.3 x 5.7 inch (HxD)
320-120_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 21
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC red Part no.: 914142


Visual notification device in red colour for signalling
fire hazards, approved according EN 54-23 and VdS.
The beacon is impressive due to its safe and simple
mounting with external lugs or internal holes, simple
electrical connection on the bottom of the casing.
Impact-proof lens. Equipped with an electronic soft start
module for operation directly on a primary control group of
the fire alarm panel via a voltage increase.

Technical specifications Included in delivery


1 Beacon PY X-S-05-SSM 24 DC red
Dome material PC, red
Enclosure material PC / ABS Blend, red
Not included in delivery
Approved category
O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour red
Connection / mounting
IP rating IP 66 Recommended cable 2-wire
-40 °C to +55 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating temperature
(-40 °F to +131 °F)
Relative humidity max. 90 % Note
Operating voltage 18 V to 30 V DC The beacon has three pre-cut cable openings. The device
Rated current consumption 300 mA can be operated via the voltage increase function as well as
via the voltage reversal function at the FMZ 5000 and FMZ
Power consumption approx. 7.2 W 5000 mod S control panels. The device has an integrated
Luminous intensity 13 cd reverse polarity protection diode.
Flash energy 5 Joule
Flash rate 1 Hz = 60 flashes / min. Approvals / marking
Weight 200 g (0.44 lbs)
109.5 x 86 x 80.6 mm (WxHxD) G 212186 0786-CPD-21219
Dimensions
4.31 x 3.39 x 3.17 inch (WxHxD)

Design parameters
The contents of this publication are subject to modifications without notice. All rights reserved.

See next page

Beacon PY X-S-05-MX 24 DC red NEW Part no.: 920565


Otherwise like part no. 914142

Note
The device can be operated only via the voltage reversal
function at the FMZ 5000 and FMZ 5000 mod S control panels.
320-310_001 / AI01_2016en

Approvals / marking

G 214121 0786-CPR-21435

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 22
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC red

Design parameters
(optimal mounting alignment)

Category O
O - 4.1 - 2.2 - 3.2 / V = 28.9 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
4.1 = max. edge length in m (Hg)
2.2 = max. edge length in m (Y)
3.2 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)

Category W (derived from category O)


W - 2.4 - 2.2 / V = 11.6 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
2.4 = max. mounting height in m (H)
2.2 = max. cube edge length in m (Y)

Category C (derived from category O)


C - 3.15 - 3.6 / V = 32 m3
Category C is designed as a cylinder.
The contents of this publication are subject to modifications without notice. All rights reserved.

Design legend:
C = ceiling mounting
3.15 = max. mounting height in m (H)
3.6 = max. cylinder diameter in m (Y)
320-310_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 23
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC clear Part no.: 914143


Visual notification device in clear colour for signalling
fire hazards, approved according EN 54-23 and VdS.
The beacon is impressive due to its safe and simple
mounting with external lugs or internal holes, simple
electrical connection on the bottom of the casing.
Impact-proof lens. Equipped with an electronic soft start
module for operation directly on a primary control group
of the fire alarm panel via a voltage increase.

Technical specifications Included in delivery


1 Beacon PY X-S-05-SSM 24 DC clear
Dome material PC, clear
Enclosure material PC / ABS Blend, red
Not included in delivery
Approved category
O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour clear
Connection / mounting
IP rating IP 66 Recommended cable 2-wire
-40 °C to +55 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating temperature
(-40 °F to +131 °F)
Relative humidity max. 90 % Note
Operating voltage 18 V to 30 V DC The beacon has three pre-cut cable openings. The device
Rated current consumption 300 mA can be operated via the voltage increase function as well as
via the voltage reversal function at the FMZ 5000 and FMZ
Power consumption approx. 7.2 W 5000 mod S control panels. The device has an integrated
Luminous intensity 55 cd reverse polarity protection diode.
Flash energy 5 Joule
Flash rate 1 Hz = 60 flashes / min. Approvals / marking
Weight 200 g (0.44 lbs)
G 212186 0786-CPD-21219
109.5 x 86 x 80.6 mm (WxHxD)
Dimensions
4.31 x 3.39 x 3.17 inch (WxHxD)
Design parameters
See next page
The contents of this publication are subject to modifications without notice. All rights reserved.

Beacon PY X-S-05-MX 24 DC clear NEW Part no.: 920566


Otherwise like part no. 914143

Note
The device can be operated only via the voltage reversal
function at the FMZ 5000 and FMZ 5000 mod S control panels.
320-310_002 / AI01_2016en

Approvals / marking

G 214121 0786-CPR-21435

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 24
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC clear

Design parameters
(optimal mounting alignment)

Category O
O - 11.1 - 8.4 - 6.3 / V = 587.4 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
11.1 = max. edge length in m (Hg)
8.4 = max. edge length in m (Y)
6.3 = max. edge length in m (X)
HM = max. 6.6 m (wall mounting only)

Category W (derived from category O)


W - 5.9 - 7.6 / V = 340 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
5.9 = max. mounting height in m (H)
7.6 = max. cube edge length in m (Y)

Category C (derived from category O)


C - 6.8 - 10.6 / V = 600 m3
Category C is designed as a cylinder.
The contents of this publication are subject to modifications without notice. All rights reserved.

Design legend:
C = ceiling mounting
6.8 = max. mounting height in m (H)
10.6 = max. cylinder diameter in m (Y)
320-310_002 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 25
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC yellow Part no.: 916318


Visual notification device in yellow colour. The beacon
is impressive due to its safe and simple mounting with
external lugs or internal holes, simple electrical
connection on the bottom of the casing. Impact-proof lens.
Equipped with an electronic soft start module for monitoring
of open and short circuits via the fire alarm panel.

Technical specifications Included in delivery


1 Beacon PY X-S-05-SSM 24 DC yellow
Dome material PC, yellow
Enclosure material PC / ABS Blend, grey
Not included in delivery
Flash technology Xenon
Mounting hardware
Flash colour yellow Cable glands
IP rating IP 66

Operating temperature
-40 °C to +55 °C Connection / mounting
(-40 °F to +131 °F) Recommended cable 2-wire
Relative humidity max. 90 % Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 18 V to 30 V DC
Rated current consumption 300 mA Note
The beacon has three pre-cut cable openings. The device
Power consumption approx. 7.2 W
can be operated via the voltage increase function as well as
Luminous intensity 51 cd via the voltage reversal function at the FMZ 5000 and FMZ
Flash energy 5 Joule 5000 mod S control panels. The device has an integrated
Flash rate 1 Hz = 60 flashes / min.
reverse polarity protection diode.

Weight 200 g (0.44 lbs)


Approvals / marking
109.5 x 86 x 80.6 mm (WxHxD)
Dimensions
4.31 x 3.39 x 3.17 inch (WxHxD)
applied for
The contents of this publication are subject to modifications without notice. All rights reserved.

Notice!
No approval according to EN 54-23.
320-310_003 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 26
Product Sheet | Detecon

Notification devices
Visual

Beacon PY X-S-05-SSM 24 DC blue Part no.: 916319

Technical specifications
Dome material PC, blue Otherwise like part no. 916318
Flash colour blue
Luminous intensity 13 cd

Beacon PY X-S-05-SSM 24 DC green Part no.: 916320

Technical specifications
Dome material PC, green Otherwise like part no. 916318
Flash colour green
Luminous intensity 14 cd
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_003 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 27
Product Sheet | Detecon

Notification devices
Visual

Beacon L101X red Part no.: 917444


Optical notification device for signaling fire hazards,
approved according EN 54-23 in categories C and O
and VdS. The beacon can be mounted using external
lugs or internal holes.

Technical specifications Included in delivery


1 Beacon L101X red
Dome material PC, red
Enclosure material ABS, red
Not included in delivery
Approved categories
C, O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour red
Connection / mounting
IP rating IP 66 Recommended cable 2-wire
-25 °C to +55 °C Conductor cross-section max. 1.5 mm2 (AWG 15)
Operating temperature
(-13 °F to +131 °F)
-40 °C to +70 °C Note
Storage temperature
(-40 °F to +158 °F)
The beacon has two pre-cut M20 cable openings. The device
Rated voltage 24 V DC can only be operated via the voltage reversal function at the
Operating voltage 20 V to 28 V DC FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Rated current consumption approx. 275 mA
Power consumption 6W
Approvals / marking
Flash energy 5 Joule
Flash rate 1 Hz = 60 flashes / min. G 211077 0786-CPD-21247
Weight 200 g (0.4 lbs)
114.6 x 86.4 x 83.3 mm (WxHxD) Note approvals
Dimensions
4.5 x 3.4 x 3.3 inch (WxHxD) This beacon cannot be included in the VdS system
approval of the FMZ 5000, due to its technical parameters
The contents of this publication are subject to modifications without notice. All rights reserved.

(minimum operation voltage)

Design parameters
See next page
320-310_004 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 28
Product Sheet | Detecon

Notification devices
Visual

Beacon L101X red

Design parameters

Category O
O - 1.9 - 3.6 / V = 13.0 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
1.9 = max. edge length in m (Hg and Y)
3.6 = max. edge length in m (X)

Category C
C - 3 - 2.6 / V = 15.9 m3
Category C is designed as a cylinder.
Design legend:
C = ceiling mounting
3 = max. mounting height in m (H)
2.6 = max. cylinder diameter in m (Y)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_004 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 29
Product Sheet | Detecon

Notification devices
Visual

Beacon L101X clear Part no.: 917443


Optical notification device for signaling fire hazards,
approved according EN 54-23 for categories C, W, O
and VdS The beacon can be mounted using external lugs
or internal holes.

Technical specifications Included in delivery


1 Beacon L101X clear
Dome material PC, clear
Enclosure material ABS, red
Not included in delivery
Approved categories
C, W, O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour clear
Connection / mounting
IP rating IP 66 Recommended cable 2-wire
-25 °C to +55 °C Conductor cross-section max. 1.5 mm2 (AWG 15)
Operating temperature
(-13 °F to +131 °F)
-40 °C to +70 °C Note
Storage temperature
(-40 °F to +158 °F)
The beacon has two pre-cut M20 cable openings. The device
Rated voltage 24 V DC can only be operated via the voltage reversal function at the
Operating voltage 20 V to 28 V DC FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Rated current consumption approx. 275 mA
Power consumption 6W
Approvals / marking
Flash energy 5 Joule
Flash rate 1 Hz = 60 flashes / min. G 211077 0786-CPD-21247
Weight 200 g (0.4 lbs)
114.6 x 86.4 x 83.3 mm (WxHxD) Note approvals
Dimensions
4.5 x 3.4 x 3.3 inch (WxHxD)
This beacon cannot be included in the VdS system approval
of the FMZ 5000, due to its technical parameters (minimum
The contents of this publication are subject to modifications without notice. All rights reserved.

operation voltage)

Design parameters
See next page
320-310_005 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 30
Product Sheet | Detecon

Notification devices
Visual

Beacon L101X clear

Design parameters

Category O
O - 4.8 - 10 / V = 230.4 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
4.8 = max. edge length in m (Hg und Y)
10 = max. edge length in m (X)

Category W
W - 2.4 - 4.8 / V = 55.3 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
2.4 = max. mounting height in m (H)
4.8 = max. cube edge length in m (Y)

Category C
C - 9 - 6,8 / V = 326.9 m3
Category C is designed as a cylinder.
Design legend:
The contents of this publication are subject to modifications without notice. All rights reserved.

C = ceiling mounting
9 = max. mounting height in m (H)
6,8 = max. cylinder diameter in m (Y)
320-310_005 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 31
Product Sheet | Detecon

Notification devices
Visual

Beacon Solista LX Wall red Part no.: 917446


Optical notification device for signaling fire hazards,
approved according EN 54-23 for category W.
The flash rate and the high power or lower power
application can be set using the DIP switches.

Technical specifications Included in delivery


1 Beacon Solista LX Wall red
Enclosure material ABS, red
Approved categories
according EN 54-23
W Not included in delivery
Mounting hardware
Flash technology LED
Cable glands
Flash colour red
IP rating IP 65
Connection / mounting
-25 °C to +70 °C Recommended cable 2-wire
Operating temperature
(-13 °F to +158 °F) Conductor cross-section max. 2.5 mm2 (AWG 13)
-25 °C to +70 °C
Storage temperature
(-13 °F to +158 °F)
Note
Rated voltage 24 V DC
The beacon has two pre-cut M20 cable openings. The device
Operating voltage 9 V to 60 V DC can only be operated via the voltage reversal function at the
High Power 1 Hz: 25 mA FMZ 5000 and FMZ 5000 mod S control panels. The device
Rated current consumption High Power 0,5 Hz: 16 mA has an integrated reverse polarity protection diode.
at 24 V DC Low Power 1 Hz: 16 mA
Low Power 0,5 Hz: 10 mA
Approvals / marking
Surge current < 120 % for 10 ms
Power consumption max. 1,5 W G 214067 0333-CPD-075441
0.5 Hz = 30 flashes / min.
Flash rate adjustable
1 Hz = 60 flashes / min.
Weight 100 g (0.2 lbs)
93 x 66 mm (dia.xH)
The contents of this publication are subject to modifications without notice. All rights reserved.

Dimensions
3.6 x 2.6 inch (dia.xH)

Design parameters

Category W
W - 2.4 - 7.5 / V = 135 m3 (high power)
W - 2.4 - 2.5 / V = 15 m3 (low power)
Category W is designed as a cube.
Design legend:
320-310_006 / AI00_2015en

W = wall mounting
2.4 = max. mounting height in m (H)
7.5/2.5 = max. cube edge length in m (Y)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 32
Product Sheet | Detecon

Notification devices
Visual

Beacon Solista LX Wall clear Part no.: 917445


Otherwise like part no. 917446

Technical specifications
Flash colour clear
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_006 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 33
Product Sheet | Detecon

Notification devices
Visual

Beacon LX Ceiling red Part no.: 917448


Optical notification device for signaling fire hazards,
approved according EN 54-23 for category C.
The flash rate and the high power or lower power
application can be set using the DIP switches.

Technical specifications Included in delivery


1 Beacon Solista LX Ceiling red
Enclosure material ABS, white
Approved categories
according EN 54-23
C Not included in delivery
Mounting hardware
Flash technology LED
Cable glands
Flash colour red
IP 33
IP rating IP 65 with extension base
Connection / mounting
(917449) Recommended cable 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
-25 °C to +70 °C
Operating temperature
(-13 °F to +158 °F)
-25 °C to +70 °C Note
Storage temperature
(-13 °F to +158 °F) The device can only be operated via the voltage reversal
Rated voltage 24 V DC function at the FMZ 5000 and FMZ 5000 mod S control
panels. The device has an integrated reverse polarity
Operating voltage 9 V to 60 V DC protection diode. The Extension base Solista Ceiling
High Power 1 Hz: 25 mA IP 65 (917449) must be additionally ordered to increase
Rated current consumption High Power 0.5 Hz: 16 mA the IP rating to IP 65.
at 24 V DC Low Power 1 Hz: 16 mA
Low Power 0.5 Hz: 10 mA
Approvals / marking
Surge current < 120 % for 10 ms
Power consumtion max. 1.5 W G 214069 0333-CPD-075443
0.5 Hz = 30 flashes / min.
Flash rate adjustable
1 Hz = 60 flashes / min.
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 100 g (0.2 lbs)


93 x 38 mm (dia.xH)
Dimensions
3.6 x 2.6 inch (dia.xH)

Design parameters

Category C
C - 3 - 7.5 / V = 132 m3 (high power)
C - 3 - 3 / V = 21.2 m3 (low power)
Category C is designed as a cylinder.
Design legend:
320-310_007 / AI00_2015en

C = ceiling mounting
3 = max. mounting height in m (H)
7.5/3 = max. cylinder diameter in m (Y)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 34
Product Sheet | Detecon

Notification devices
Visual

Beacon Solista LX Ceiling clear Part no.: 917447


Otherwise like part no. 917448

Technical specifications
Flash colour clear

Design parameters

Category C
C - 3 - 7.5 / V = 132 m3 (high power)
C - 3 - 5 / V = 58.9 m3 (low power)
Category C is designed as a cylinder.
Design legend:
C = ceiling mounting
3 = max. mounting height in m (H)
7.5/5 = max. cylinder diameter in m (Y)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_007 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 35
Product Sheet | Detecon

Notification devices
Visual

Beacon Solex MX Part no.: 908632


Optical notification device for signalling fire hazards.

Technical specifications Included in delivery


1 Beacon Solex MX
Dome material PC, red
Enclosure material ABS, red
Not included in delivery
IP rating IP 65
Mounting hardware
-25 °C to +70 °C Cable glands
Ambient temperature
(-13 °F to +158 °F)
Rated voltage 24 V DC
Note
Operating voltage 10 V - 60 V DC The beacon can only be operated via the voltage reversal
Rated current consumption 100 mA function at the FMZ 5000 and FMZ 5000 mod S control
panels. The device has an integrated reverse polarity
Power consumption 2.4 W
protection diode.
Luminous intensity 10 cd
Flash rate 1 Hz = 60 flashes / min. Approvals / marking
Weight 180 g (0.4 lbs)
93 x 121 mm (WxH)
Dimensions
3.7 x 4.8 inch (WxH)

Notice!
This beacon must not be used for alerting and evacuation
of people in fire alarm or gas extinguishing systems.
The contents of this publication are subject to modifications without notice. All rights reserved.

The device is not EN 54-23 or VdS approved.


320-310_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 36
Product Sheet | Detecon

Notification devices
Visual

Beacon SR Part no.: 918426


Visual notification device for signalling fire hazards.
This beacon is listed for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable candela settings via slide switch 1 Beacon SR
(15, 15/75, 30, 75, 95, 110, 115 cd)
• For indoor use Not included in delivery
Back box
Mounting hardware

Technical specifications
Connecting / mounting
Enclosure material PC/ABS Blend, red
Connection cable 2-wire
Flash technology Xenon Conductor cross-section max. 3.3 mm2 (AWG 12)
Flash colour white
0 °C to +49 °C Note
Operating temperature
(+32 °F to +120.2 °F)
Applicable for operation with the fire alarm panel
Rated voltage 24 V DC FMZ 5000 mod S CA (918493).
Operating voltage 8 - 33 V DC
66 to 210 mA
Rated current consumption Approvals / marking
depending on candela setting
Flash rate 1 Hz = 60 flashes / min.
Weight 240 g (0.5 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_013 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 37
Product Sheet | Detecon

Notification devices
Visual

Beacon SRK Part no.: 918427


Visual notification device for signalling fire hazards.
This beacon is listed for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable candela settings via slide switch 1 Beacon SRK
(15, 15/75, 30, 75, 95, 110, 115 cd) 1 Weatherproof back box

• For outdoor use


Not included in delivery
Mounting hardware

Technical specifications
Connecting / mounting
Enclosure material PC Connection cable 2-wire
Flash technology Xenon Conductor cross-section max. 3.3 mm2 (AWG 12)
Flash colour white
IP rating IP 56 Note
Applicable for operation with the fire alarm panel
IP rating NEMA 4X
(American NEMA Standard Publ. 250) FMZ 5000 mod S CA (918493).
-40 °C to +66 °C
Operating temperature
(-40 °F to +150.8 °F) Approvals / marking
Rated voltage 24 V DC
Operating voltage 8 - 33 V DC
66 to 210 mA
Rated current consumption
depending on candela setting
Flash rate 1 Hz = 60 flashes / min.
Weight 500 g (1.1 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
The contents of this publication are subject to modifications without notice. All rights reserved.

4.7 x 5.6 x 1.3 inch (WxHxD)


320-310_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 38
Product Sheet | Detecon

Notification devices
Visual

Beacon High Candela SRH Part no.: 918428


Visual notification device for signaling fire hazards.
This beacon is listed for ceiling or wall mounting.

Product features Included in delivery


1 Beacon High Candela SRH
• High candela range
• Field-selectable candela settings via slide switch
(135, 150, 177 or 185 cd)
Not included in delivery
Back box
• For indoor use Mounting hardware

Connecting / mounting
Technical specifications Recommended cable 2-wire
Conductor cross-section  max. 3.3 mm² (AWG 12)
Enclosure material PC/ABS Blend, red
Flash technology Xenon
Note
Flash colour white
Applicable for operation with the fire alarm panel
0°C to +49°C FMZ 5000 mod S CA (918493).
Operating temperature
(+32 °F to +120.2 °F)
Rated voltage 24 V DC
Operating voltage 16 - 33 V DC Approvals / marking
228 - 286 mA
Rated current consumption
depending on candela setting
Flash rate 1 Hz = 60 flashes / min.
Weight 240 g (0.5 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_015 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 39
Product Sheet | Detecon

Notification devices
Visual

Beacon High Candela SRHK Art.-Nr.: 918429


Visual notification device for signaling fire hazards.
This beacon is listed for ceiling or wall mounting.

Product features Included in delivery


• High candela range 1 Beacon High Candela SRHK
1 Weatherproof back box
• Field-selectable candela settings via slide switch
(135, 150, 177 or 185 cd).
Not included in delivery
• For outdoor use Mounting hardware

Connecting / mounting
Technical specifications Recommended cable 2-wire
Conductor cross-section  max. 3.3 mm² (AWG 12)
Enclosure material PC, red
Flash technology Xenon
Note
Flash colour white
Applicable for operation with the fire alarm panel
IP rating IP 56 FMZ 5000 mod S CA (918493).
IP rating NEMA 4X
(American NEMA Standard Publ. 250)

Operating temperature
-40°C to +66°C Approvals / marking
(-40 °F to +150.8 °F)
Rated voltage 24 V DC
Operating voltage 16 - 33 V DC
228 - 286 mA
Rated current consumption
depending on candela setting
Flash rate 1 Hz = 60 flashes / min.
Weight 500 g (1.1 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

119 x 142 x 33 mm (WxHxD)


Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
320-310_016 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 40
Product Sheet | Detecon

Notification devices
Visual

Rotating beacon R401-61 red Part no.: 917450


Optical notification device for signaling fire hazards.
360° rotating beacon with parabola reflector. The connection
cable can be inserted via an M20 cable opening or through
the base of the rotating beacon.

Included in delivery
Technical specifications
1 Rotating beacon R401-61 red
Dome material PC, red 1 Foam rubber disk
Base material ABS, black
IP rating IP 65 Not included in delivery
-10 °C to +55 °C Mounting hardware
Operating temperature
(14 °F to +131 °F) Cable glands
-10 °C to +55 °C
Storage temperature
(14 °F to +131 °F) Connection / mounting
Rated voltage 24 V DC Recommended cable 2-wire
Operating voltage 20 V - 28 V DC Conducter cross-section max. 2.5 mm2 (AWG 13)
Rated current consumption 0.95 A
Power consumption 21 W
Note
The rotating beacon has a pre-cut M20 cable opening.
Weight 980 g (2.2 lbs)
The device can only be triggered via relay contacts.
150 x 205 mm (DxH)
Dimensions
5.9 x 8.1 inch (DxH)
Approvals / marking

Rotating beacon R401-61 amber Part no.: 917451


Otherwise like Part no. 917450
The contents of this publication are subject to modifications without notice. All rights reserved.
320-310_009 / AI00_2015en

Technical specifications
Dome material PC, amber

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 41
Product Sheet | Detecon

Notification devices
Visual, addressable

Loop Beacon LBX 877r Part no.: 905820


Loop Beacon for optical signalling in red.
The beacon can be fitted to any Loop AP detector base.
Addressing is done via an integrated address card.

Included in delivery
Technical specifications
1 Loop Beacon LBX 877r
Enclosure material PC
IP rating IP 23D Not included in delivery
Technology / protocol Loop AP / XP95 Mounting hardware
Enclosure colour white Detector base for Loop AP
Spherical cup colour red
Integrated isolator no Connection / mounting
Cable recommendation standard
-20 °C to +60 °C
Operating temperature
(-4 °F to +140 °F) J-Y(St)Y -2x2x0.8 mm, red 747180
Recommended cable 2-wire
Operating voltage 17 V - 28 V DC Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating current siren 3 mA Electrostatic shielding not required
Rated current consumption 150 µA
0 - 95 % Approvals / marking
Relative humidity
no condensation
Weight 140 g (0.30 lbs)
115 x 38 mm (dia.xH)
Dimensions
4.52 x 1.49 inch (dia.xH)

Notice!
This beacon must not be used for alerting and evacuation
of people in fire alarm or gas extinguishing systems.
The contents of this publication are subject to modifications without notice. All rights reserved.

The device is not EN 54-23 or VdS approved.


320-310_010 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 42
Product Sheet | Detecon

Notification devices
Visual, addressable

Loop Beacon LBX 009r WP Part no.: 912569


Loop beacon for the LoopAP for optical signalling
with integrated dual isolator in red. Addressing is
done via integrated DIP switches.

Included in delivery
Technical specifications
1 Loop Beacon LBX 009r WP
Enclosure material PC
IP rating IP 65 Not included in delivery
Technology / protocol Loop AP / XP95 Mounting hardware
Enclosure colour red
Spherical cup colour red Connection / mounting
Integrated isolator yes Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red 747180
-10 °C to +55 °C
Operating temperature
(-14 °F to +131 °F) Recommended cable 2-wire
Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating voltage 17 V - 28 V DC Electrostatic shielding not required
Operating current siren 3.1 mA
Rated current consumption 330 µA
Approvals / marking
Weight 205 g (0.45 lbs)
104 x 97.5 mm (dia.xH)
Dimensions
4.09 x 3.83 inch (dia.xH)

Notice!
This beacon must not be used for alerting and evacuation
of people in fire alarm or gas extinguishing systems.
The contents of this publication are subject to modifications without notice. All rights reserved.

The device is not EN 54-23 or VdS approved.


320-310_011 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 43
Product Sheet | Detecon

Notification devices
Visual, Ex

Beacon Quadro-LED Flex-3GD-MX Part no.: 908035


Visual notification device for signalling fire hazards in
potentially explosive atmospheres in zone 2 and 22.
Fitted with an electronic module for operation directly
on a primary control group of the fire alarm panel via a
voltage increase.

Product features Included in delivery


• Explosion-protected equipment 1 Beacon Quadro-LED Flex-3GD-MX
• Choice of operating modes for 4 different alarm signals:
steady light, flashing light, strobe light and rotating light Not included in delivery
• Applications: industrial presses Mounting hardware

Connection / mounting
Technical specifications Recommended cable 2-wire
Conductor cross-section 0.2 mm2 to 6 mm2
Dome material PC, red
(AWG 23 to AWG 9)
Enclosure material PC, grey
Light source 16 LEDs Note
-20 °C to +50 °C (T6) The beacon can be operated via the voltage increase
-4 °F to +122 °F (T6) function as well as via the voltage reversal function at the
Ambient temperatures
-20 °C to +55 °C (T5) FMZ 5000 and FMZ 5000 mod S control panels. The device
-4 °F to +131 °F (T5)
has an integrated reverse polarity protection diode.
Relative humidity max. 90 %
Rated voltage 24 V DC
Approvals / marking
Flashing light 1 Hz = 60 flashes / min.
Ex classification:  x II 3G Ex nRc IIC T6 -20°C ≤ Ta ≤ +50°C
Strobe light 1.5 Hz = 90 flashes / min. x II 3G Ex nRc IIC T5 -20°C ≤ Ta ≤ +55°C
Rotating light 2.5 Hz = 150 flashes / min. x II 3D Ex tc IIIB T90°C IP 66 -20°C ≤ TA ≤ +55°C
Operating voltage 15 V - 30 V DC
Rated current consumption approx. 300 mA
The contents of this publication are subject to modifications without notice. All rights reserved.

Power consumption 7.2 W


Luminous intensity 6.1 cd with steady light
IP rating (EN 60529) IP 66
Service life of beacon > 50000 hrs
Duty cycle 100 %
Weight 500 g (1.1 lbs)
130 x 130 x 130 mm (WxHxD)
Dimensions
5.1 x 5.1 x 5.1 inch (WxHxD)
320-320_001 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 44
Product Sheet | Detecon

Notification devices
Visual, Ex

Beacon CWB-ATEX-MX Ex Part no.: 903761


Visual notification device for signalling fire hazards in
potentially explosive atmospheres in zone 1 as well as
zones 21. Fitted with an electronic module for monitoring
directly on a primary control group of the fire alarm panel
via a voltage increase.

Product features Included in delivery


• Explosion-protected equipment 1 Beacon CWB-ATEX-MX Ex complete with mounting bracket
• Aluminium enclosure
• Applications: chemical and petrochemical facilities Not included in delivery
and offshore facilities Mounting hardware

Connection / mounting
Technical specifications Recommended cable 2-wire
Dome material PC, red Conductor cross-section:
Enclosure material Aluminium alloy, yellow/black - power supply max. 2.5 mm2 (AWG 13)
- protective earth terminal
Flash energy 5 joules outside max. 6 mm2 (AWG 9)
-40 °C to +40 °C (T6 / T85°C) inside max. 2.5 mm2 (AWG 13)
(-40 °F to +104 °F (T6 / T85°C))
Ambient temperatures
-40 °C to +50 °C (T5 / T100°C)
(-40 °F to +122 °F (T5 / T100°C)) Note
-40 °C to +80 °C The beacon can be operated via the voltage increase
Storage temperature function as well as via the voltage reversal function at the
(-40 °F to +140 °F)
FMZ 5000 and FMZ 5000 mod S control panels. The device
Relative humidity max. 90 %
has an integrated reverse polarity protection diode.
Rated voltage 24 V DC
Operating voltage 18 V - 30 V DC Approvals / marking
Rated current consumption 400 mA
Ex classification: x II 2G Ex de IIC T6/T5 Gb
Power consumption 9.6 W x II 2D Ex tb IIIC T85°C/T100°C Db IP66
Luminous intensity 9 cd
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 66


Flash rate 1 Hz = 60 flashes / min.
Service life of beacon approx. 5800 hrs
Duty cycle 100 %
Weight 1240 g (7.73 lbs)
70 x 260 mm (dia. x H)
Dimensions
2.8 x 10.2 inch (dia. x H)
320-320_002 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 45
Product Sheet | Detecon

Notification devices
Visual, Ex

Beacon CWB-ATEX-MX Ex Part no.: 905344


Otherwise like part no. 903761

Technical specifications
Dome material PC, yellow

Beacon CWB-ATEX-MX Ex Part no.: 905343


Otherwise like part no. 903761

Technical specifications
Dome material PC, blue
The contents of this publication are subject to modifications without notice. All rights reserved.
320-320_002 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 46
Product Sheet | Detecon

Notification devices
Visual, Ex

Beacon FL60 MX Ex Part no.: 910656


Optical alarm device for signalling danger of fire that is
especially suitable for use in industrial environments with
hazard areas in zone 1 as well as 21. Equipped with an
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.
The robust aluminium housing is resistant to sea water,
environmental effects and chemicals.

Product features Included in delivery


• Explosion-proof device for 1 Beacon FL60 MX Ex
hazardous zone 1 as well as 21 1 Blanking plug
• Fitted as standard with protective cage
Not included in delivery
Mounting hardware
Technical specifications
Horn material PC, red Connection / mounting
Recommended cable 2-wire
Enclosure material Diecast aluminium, red
Conductor cross-section: 2.5 mm2 (AWG 13)
-35 °C to +60 °C (T4 / T135°C)
(-31 °F to +140 °F (T4 / T135°F))
Operating temperature Note
-35 °C to +40 °C (T6 / T85°C)
(-31 °F to +104 °F (T6 / T85°F)) The beacon can be operated via the voltage increase
-35 °C to +60 °C) function as well as via the voltage reversal function at the
Storage temperature
(-31 °F to +140 °F) FMZ 5000 and FMZ 5000 mod S control panels. The device
Relative humidity max. 95 %
has an integrated reverse polarity protection diode.

Rated voltage 24 V DC
Flash rate 1 Hz = 60 flashes / min.
Approvals / marking
Flash energy 5J Ex classification: x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
Operating voltage 18 V - 30 V DC
x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP 66
Rated current consumption approx. 220 mA x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP 66
Power consumption 5.3 W
Luminous itensity 6.1 cd with continous light
The contents of this publication are subject to modifications without notice. All rights reserved.

IP rating (EN 60529) IP 66


Weight 5080 g (11.2 lbs)
276 x 145 mm (HxD)
Dimensions
10.9 x 5.7 inch (HxD)
320-320_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 47
Product Sheet | Detecon

Notification devices
Visual, Ex

Beacon BExBG05E MX Ex Part no.: 913425


Optical alarm device for signalling danger of fire that is
especially suitable for use in industrial environments
with hazard areas in zone 1 as well as 21. Equipped with
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.
The robust aluminium housing is resistant to sea water,
environmental effects and chemicals.

Product features Included in delivery


• Explosion-proof equipment for 1 Beacon BExBG05E MX Ex with mounting bracket
Ex zone 1 as well as 21
• Fitted as standard with protective cage Not included in delivery
Mounting hardware

Technical specifications Connection / mounting


Spherical calotte material Borosilicate glass, red Recommended cable 2-wire
Conductor cross-section: 0.5 mm2 to 4 mm2
Enclosure material Aluminium, red
(AWG 20 to AWG 11)
-50 °C to +70 °C (T4)
-58 °F to +158 °F (T4)
-50 °C to +55 °C (T5) Note
Operating temperature 2G
-58 °F to +131 °F (T5) The beacon can be operated via the voltage increase
-50 °C to +40 °C (T6) function as well as via the voltage reversal function at the
-58 °F to +104 °F (T6) FMZ 5000 and FMZ 5000 mod S control panels. The device
Rated voltage 24 V DC has an integrated reverse polarity protection diode.
Flash rate 1 Hz = 60 flashes / min.
Flash energy 5J Approvals / marking
Operating voltage 20 V - 28 V DC Ex classification: x II 2G Ex de IIC T4 Ta.-50°C to +70°C
Rated current consumption approx. 300 mA x II 2G Ex de IIC T5 Ta.-50°C to +55°C
Power consumption 7.2 W
x II 2G Ex de IIC T6 Ta.-50°C to +40°C
x II 2D tD A21 IP 66 T115°C
IP rating (EN 60529) IP 66
Weight 2450 g (5.4 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

295 x 154 mm (HxD)


Dimensions 11.61 x 6.06 inch (HxD)
(without mounting bracket)
320-320_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 48
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon PA X-1-05-SSM 24 DC red Part no.: 914144


Audible/visual notification device in red colour for signalling
fire hazards, approved according EN 54-3, EN 54-23 and
VdS. The sounder/beacon is impressive due to its safe
and simple mounting with external lugs or internal holes,
simple electrical connection on the bottom of the casing.
The sounder/beacon is impact-proof.
Equipped with an electronic soft start module for operation
directly on a primary control group of the fire alarm panel
via a voltage increase.

Technical specifications Included in delivery


1 Sounder / Beacon PA X-1-05-SSM 24 DC red
Dome material PC, red
Enclosure material PC / ABS Blend, red
Not included in delivery
Approved categories
O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash color red
Connection / mounting
IP rating IP 66
Recommended cable 2-wire
-40 °C to +55 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating temperature
(-40 °F to +131 °F)
Relative humidity approx. 90 %
Note
Operating voltage 18 V - 30 V DC
The combination unit has three pre-cut cable openings.
Rated current consumption: The device can be operated via the voltage increase function
Beacon 300 mA as well as via the voltage reversal function at the FMZ 5000
Sounder 38 mA (at 24 V / DIN-Ton) and FMZ 5000 mod S control panels. The device has an
Power consumption approx. 8.1 W integrated reverse polarity protection diode.
Luminous intensity 13 cd
Flash energy 5 Joule Approvals / marking
Flash rate 1 Hz = 60 flashes / min.
G 212188 0786-CPD-21220
Tones 80
Tone stages 3 additional externally selectable
Sound pressure up to 100 dB (A) / 1 m Beacon design parameters
See next page
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 560 g (1.23 lbs)


109.5 x 172.4 x 80.6 mm (WxHxD)
Dimensions
4.31 x 6.79 x 3.17 inch (WxHxD)

Sounder / Beacon PA X-1-05-MX 24 DC red NEW Part no.: 920568


Otherwise like part no. 914144

Note
The device can be operated only via the voltage reversal
320-510_001 / AI01_2016en

function at the FMZ 5000 and FMZ 5000 mod S control panels.

Approvals / marking

G 214120 0786-CPR-21434
1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 49
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon PA X-1-05-SSM 24 DC red

Beacon design parameters


(optimal mounting alignment)

Category O
O - 4.1 - 2.2 - 3.2 / V = 28.9 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
4.1 = max. edge length in m (Hg)
2.2 = max. edge length in m (Y)
3.2 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)

Category W (derived from category O)


W - 2.4 - 2.2 / V = 11.6 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
2.4 = max. mounting height in m (H)
2.2 = max. cube edge length in m (Y)

Category C (derived from category O)


C - 3.15 - 3.6 / V = 32 m3
Category C is designed as a cylinder.
Design legend:
C = ceiling mounting
3.15 = max. mounting height in m (H)
The contents of this publication are subject to modifications without notice. All rights reserved.

3.6 = max. cylinder diameter in m (Y)


320-510_001 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 50
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon PA X-1-05-SSM 24 DC Part no.: 914145


clear Audible/visual notification device in clear colour for signalling
fire hazards, approved according EN 54-3, EN 54-23 and
VdS. The sounder/beacon is impressive due to its safe
and simple mounting with external lugs or internal holes,
simple electrical connection on the bottom of the casing.
The sounder/beacon is impact-proof.
Equipped with an electronic soft start module for operation
directly on a primary control group of the fire alarm panel
via a voltage increase.

Technical specifications Included in delivery


1 Sounder / Beacon PA X-1-05-SSM 24 DC clear
Dome material PC, clear
Enclosure material PC / ABS Blend, red
Not included in delivery
Approved categories
O Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour clear
Connection / mounting
IP rating IP 66 Recommended cable 2-wire
-40 °C to +55 °C Conductor cross-section max. 2.5 mm2 (AWG 13)
Operating temperature
(-40 °F to +131 °F)
Relative humidity approx. 90 % Note
Operating voltage 18 V - 30 V DC The combination unit has three pre-cut cable openings.
Rated current consumption: The device can be operated via the voltage increase function
Beacon 300 mA as well as via the voltage reversal function at the FMZ 5000
Sounder 38 mA (at 24 V / DIN-Ton) and FMZ 5000 mod S control panels. The device has an
Power consumption approx. 8.1 W
integrated reverse polarity protection diode.

Luminous intensity 55 cd
Approvals / marking
Flash energy 5 Joule
Flash rate 1 Hz = 60 flashes / min.
G 212188 0786-CPD-21220
Tones 80
Tone stages 3 additional externally selectable
Beacon design parameters
Sound pressure up to 100 dB (A) / 1 m See next page
The contents of this publication are subject to modifications without notice. All rights reserved.

Weight 560 g (1.23 lbs)


109.5 x 172.4 x 80.6 mm (WxHxD)
Dimensions
4.31 x 6.79 x 3.17 inch (WxHxD)

Sounder / Beacon PA X-1-05-SSM 24 DC NEW Part no.: 920569


clear Otherwise like part no. 914145

Note
The device can be operated only via the voltage reversal
320-510_002 / AI01_2016en

function at the FMZ 5000 and FMZ 5000 mod S control panels.

Approvals / marking

G 214120 0786-CPR-21434
1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 51
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon PA X-1-05-SSM 24 DC


clear

Beacon design parameters


(optimal mounting alignment)

Category O
O - 11.1 - 8.4 - 6.3 / V = 587.4 m3
Category O is designed as a cuboid.
Design legend:
O = open mounting position
11,1 = max. edge length in m (Hg)
8,4 = max. edge length in m (Y)
6,3 = max. edge length in m (X)
HM = max. 6.6 m (wall mounting only)

Category W (derived from category O)


W - 5.9 - 7.6 / V = 340 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
5.9 = max. mounting height in m (H)
7.6 = max. cube edge length in m (Y)

Category C (derived from category O)


The contents of this publication are subject to modifications without notice. All rights reserved.

C - 6.8 - 10.6 / V = 600 m3


Category C is designed as a cylinder.
Design legend:
C = ceiling mounting
6.8 = max. mounting height in m (H)
10.6 = max. cylinder diameter in m (Y)
320-510_002 / AI01_2016en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 52
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon SONFL1X red Part no.: 917453


Optical and audible notification device for signaling
fire hazards. The combination unit can be mounted
using external lugs or internal holes.

Technical specifications Included in delivery


1 Sounder / Beacon SONFL1X red
Dome material PC, red
Enclosure material ABS, red
Not included in delivery
Flash technology Xenon
Mounting hardware
Flash colour red Cable glands
Flash energy 5 Joule
IP rating IP 66 Connection / mounting
-25 °C to +55 °C Recommended cable 2-wires
Operating temperature Conductor cross-section 1.5 mm2 (AWG 15)
(-13 °F to +131 °F)
-40 °C to +70 °C
Storage temperature
(-40 °F to +158 °F) Note
Rated voltage 24 V DC The device has three pre-cut M20 cable openings. The
Operating temperature 20 V - 28 V DC device can only be operated via the voltage reversal function
at the FMZ 5000 and FMZ 5000 mod S control panels. The
Rated current consumption approx. 340 mA device has an integrated reverse polarity protection diode.
Power consumption 8W
Flash rate 1 Hz = 60 flashes / min. Approvals / marking
Duty cycle 100 %
Tones 10
Sound pressure to 100 dB (A) 1 m
Relative humidity max. 90% at 20 °C (68 °F)
Weight 500 g (1.1 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

114.6 x 172 x 84 mm (WxHxD)


Dimensions
4.5 x 6.8 x 3.3 inch (WxHxD)
Notice!
This combination must not be used for alerting and evacuation
of people in fire detection or gas extinguishing systems.
The device is not EN 54-23 or VdS approved.
320-510_003 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 53
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon SONFL1X clear Part no.: 917452


Optical and audible notification device for signaling fire
hazards, approved for EN 54-3, EN 54-23 and VdS in colour
clear. The combination unit can be mounted using external
lugs or internal holes.

Technical specifications Included in delivery


1 Sounder / Beacon SONFL1X clear
Dome material PC, clear
Enclosure material ABS, red
Not included in delivery
Approved categories
W Mounting hardware
according EN 54-23
Cable glands
Flash technology Xenon
Flash colour clear
Connection / mounting
Flash energy 5 Joule Recommended cable 2-wires
IP rating IP 66 Conductor cross-section 1.5 mm2 (AWG 15)
-25 °C to +55 °C
Operating temperature
(-13 °F to +132 °F) Note
-40 °C to +70 °C The device has three pre-cut M20 cable openings. The
Storage temperature
(-40 °F to +158 °F) device can only be operated via the voltage reversal function
Rated voltage 24 V DC at the FMZ 5000 and FMZ 5000 mod S control panels. The
device has an integrated reverse polarity protection diode.
Operating voltage 20 V - 28 V DC
Rated curren consumption approx. 340 mA
Approvals / marking
Power consumption 8W
Flash rate 1 Hz = 60 flashes / min. G 214028 0786-CPR-21348
Duty cycle 100 %
Tones 10 Note approvals
Sound pressure to 100 dB (A) 1 m This Sounder / beacon cannot be included in the VdS system
approval of the FMZ 5000, due to its technical parameters
The contents of this publication are subject to modifications without notice. All rights reserved.

Relative humidity max. 90% at 20 °C (68 °F)


(minimum operation voltage)
Weight 500 g (1.1 lbs)
114.6 x 172 x 84 mm (WxHxD)
Dimensions Beacon design parameters
4.5 x 6.8 x 3.3 inch (WxHxD)
See next page
320-510_004 / AI00_2015en

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 54
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon SONFL1X clear

Beacon design parameters

Category W
W - 2.4 - 4.8 / V = 55.3 m3
Category W is designed as a cube.
Design legend:
W = wall mounting
2.4 = max. mounting height in m (H)
4.8 = max. cube edge length in m (Y)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_004 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 55
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon ROLP LX Wall red Part no.: 917455


Optical and audible notification device for signaling fire
hazards, approved according EN 54-3 and EN 54-23 for
category W. The flash rate and the high power or lower
power application can be set using the DIP switch.
The sounder volume is also set via the DIP switch.

Technical specifications Included in delivery


1 Sounder / Beacon ROLP LX Wall red
Enclosure material ABS, red
Approved categories
according EN 54-23
W Not included in delivery
Mounting hardware
Flash technology LED
Cable glands
Flash colour red
IP rating IP 65
Connection / mounting
-25 °C to +70 °C Recommended cable 2-wires
Operating temperature
(-13 °F to +158 °F) Conductor cross-section 2.5 mm2 (AWG 13)
-25 °C to +70 °C
Store temperature
(-13 °F to +158 °F)
Note
Raed voltage 24 V DC
The device has two pre-cut M20 cable openings. The device
Operating voltage 9 V - 60 V DC can only be operated via the voltage reversal function at the
High Power 1 Hz: 55 mA FMZ 5000 and FMZ 5000 mod S control panels. The device
Raed current consumption High Power 0.5 Hz: 46 mA has an integrated reverse polarity protection diode.
at 24 V DC Low Power 1 Hz: 46 mA
Low Power 0.5 Hz: 40 mA
Approvals / marking
Surge current < 120 % for 10 ms
0.5 Hz = 30 flashes / min. G 214070
Flash sequence adjustable 0333-CPR-075444
1 Hz = 60 flashes / min.
Tones 32
Sound pressure up to 102 dB (A) 1 m
Weight 200 g (0.4 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

135 x 95 x 95 mm (WxHxD)
Dimensions
5.3 x 3.7 x 3.7 inch (WxHxD)

Design parameters

Category W
W - 2.4 - 7.5 / V = 135 m3 (high power)
W - 2.4 - 2.5 / V = 15 m3 (low power)
Category W is designed as a cube.
Design legend:
320-510_005 / AI00_2015en

W = wall mounting
2.4 = max. mounting height in m (H)
2.5/7.5 = max. cube edge length in m (Y)

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 56
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder / Beacon ROLP LX Wall clear Part no.: 917454


Otherwise like part no. 917455

Technical specifications
Flash colour clear
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_005 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 57
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder/Beacon P2R Part no.: 918430


Visual and audible notification device in clear colour
for signalling fire hazards. This sounder/beacon is listed
for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable: 1 Sounder / Beacon P2R
- Horn tone and volume via rotary swich
- Candela setting via slide switch Not included in delivery
(15, 15/75, 30, 75, 95, 110, 115 cd) Back box
• For indoor use Mounting hardware

Connecting / mounting
Connection cable 2-wire
Technical specifications
Conductor cross-section max. 3.3 mm2 (AWG 12)
Enclosure material PC/ABS Blend, red
Flash technology Xenon Note
Flash colour white Applicable for operation with the fire alarm panel
0 °C to +49 °C FMZ 5000 mod S CA (918493).
Operating temperature
(+32 °F to +120.2 °F)
10 to 93% Approvals / marking
Relative humidity
no condensation
Rated voltage 24 V DC
Operating voltage 8 V - 33 V DC
66 - 229 mA
Rated current consumption depending on sound
setting and candela
Luminous intensity up to 115 cd (adjustable)
Flash rate 1 Hz = 60 flashes / min.
The contents of this publication are subject to modifications without notice. All rights reserved.

Tones 3
Tone stages 3
Sound pressure up to 101 dB
Weight 270 g (0.6 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
320-510_014 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 58
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder/Beacon P2RK Part no.: 918431


Visual and audible notification device in clear colour
for signalling fire hazards. This sounder/beacon is listed
for ceiling or wall mounting.

Product features Included in delivery


• Field-selectable: 1 Sounder / Beacon P2RK
- Horn tone and volume via rotary swich 1 Weatherproof back box
- Candela setting via slide switch
(15, 15/75, 30, 75, 95, 110, 115 cd) Not included in delivery
• For outdoor use Mounting hardware

Connecting / mounting
Technical specifications Connection cable 2-wire
Conductor cross-section max. 3.3 mm2 (AWG 12)
Enclosure material PC, red
Flash technology Xenon
Note
Flash colour white
Applicable for operation with the fire alarm panel
IP rating IP 56 FMZ 5000 mod S CA (918493).
IP rating NEMA 4X
(American NEMA Standard Publ. 250)

-40 °C to +66 °C
Approvals / marking
Operating temperature
(-40 °F to +151 °F)
10 to 93%
Relative humidity
no condensation
Rated voltage 24 V DC
Operating voltage 8 V - 33 V DC
66 - 229 mA
Rated current consumption depending on sound
The contents of this publication are subject to modifications without notice. All rights reserved.

setting and candela


Luminous intensity up to 115 cd (adjustable)
Flash rate 1 Hz = 60 flashes / min.
Tones 3
Tone stages 3
Sound pressure up to 101 dB
Weight 525 g (1.2 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
320-510_015 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 59
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder/Beacon High Candela P2RH Part no.: 918432


Visual and audible notification device in clear colour
for signalling fire hazards. This sounder/beacon is listed
for ceiling or wall mounting.

Product features Included in delivery


1 Sounder / Beacon High Candela P2RH
• High candela range
• Field-selectable: Not included in delivery
- Horn tone and volume via rotary switch
Back box
- Candela setting via slide switch
Mounting hardware
(135, 150, 177 or 185 cd)
• For indoor use
Connecting / mounting
Connection cable 2-wire
Conductor cross-section max. 3.3 mm2 (AWG 12)
Technical specifications
Enclosure material PC/ABS Blend, red Note
Flash technology Xenon
Applicable for operation with the fire alarm panel
FMZ 5000 mod S CA (918493).
Flash colour white
0 °C to +49 °C
Operating temperature
(+32 °F to +120.2 °F) Approvals / marking
10 to 93%
Relative humidity
no condensation
Rated voltage 24 V DC
Operating voltage 8 V - 33 V DC
232 - 309 mA
Rated current consumption depending on sound
setting and candela
The contents of this publication are subject to modifications without notice. All rights reserved.

Luminous intensity up to 185 cd (adjustable)


Flash rate 1 Hz = 60 flashes / min.
Tones 3
Tone stages 3
Sound pressure up to 101 dB
Weight 270 g (0.6 lbs)
119 x 142 x 33 mm (WxHxD)
Dimensions
4.7 x 5.6 x 1.3 inch (WxHxD)
320-510_016 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 60
Product Sheet | Detecon

Notification devices
Audible / visual

Sounder/Beacon High Candela P2RHK Part no.: 918433


Visual and audible notification device in clear colour
for signalling fire hazards. This sounder/beacon is listed
for ceiling or wall mounting.

Product features Included in delivery


• High candela range 1 Sounder / Beacon High Candela P2RHK
1 Weatherproof back box
• Field-selectable:
- Horn tone and volume via rotary switch
- Candela setting via slide switch Not included in delivery
(135, 150, 177 or 185 cd) Mounting hardware

• For outdoor use


Connecting / mounting
Connection cable 2-wire
Conductor cross-section max. 3.3 mm2 (AWG 12)
Technical specifications
Enclosure material PC, red Note
Flash technology Xenon Applicable for operation with the fire alarm panel
FMZ 5000 mod S CA (918493).
Flash colour white
IP rating IP 56
IP rating NEMA 4X Approvals / marking
(American NEMA Standard Publ. 250)

-40 °C to +66 °C
Operating temperature
(-40 °F to +150.8 °F)
10 to 93%
Relative humidity
no condensation
Rated voltage 24 V DC
Operating voltage 16 V - 33 V DC
The contents of this publication are subject to modifications without notice. All rights reserved.

232 - 309 mA
Rated current consumption depending on sound
setting and candela
Luminous intensity up to 185 cd (adjustable)
Flash rate 1 Hz = 60 flashes / min.
Tones 3
Tone stages 3
Sound pressure up to 101 dB
Weight 525 g (1.2 lbs)
119 x 142 x 33 mm (WxHxD) 
Dimensions
320-510_017 / AI00_2015en

4.7 x 5.6 x 1.3 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 61
Product Sheet | Detecon

Notification devices
Audible / visual, addressable

Loop Sounder / Beacon LSBX 298r WP Part no.: 912573


Analogue addressable Loop Sounder / Beacon for acoustic
and optical alarms with integrated dual isolator in red.
Addressing is done via integrated DIP switches.

Technical specifications Included in delivery


1 Loop Sounder / Beacon LSBX 298r WP
Enclosure material PC
IP rating IP 66
Not included in delivery
Technology / protocol Loop AP / XP95
Mounting hardware
Sound pressure up to 100 db
Enclosure colour red Connection / mounting
Spherical cup colour red Cable recommendation standard
Integrated isolator yes J-Y(St)Y -2x2x0.8 mm, red 747180
Recommended cable 2-wire
-20 °C to +70 °C
Operating temperature Conductor cross-section max. 2.5 mm2 (AWG 13)
(-4 °F to +158 °F)
Electrostatic shielding not required
Operating voltage 18 V - 28 V DC
Operating current siren 9 mA
Approvals / marking
Rated current consumption 350 µA
Weight 294 g (0.65 lbs) G 210023
110 x 110 x 113 mm (WxHxD)
Dimensions
4.33 x 4.33 x 4.44 inch (WxHxD)

Notice!
This combination must not be used for alerting and evacuation
The contents of this publication are subject to modifications without notice. All rights reserved.

of people in fire detection or gas extinguishing systems.


The device is not EN 54-23 or VdS approved.
The VdS approval is only based on EN 54-3 for sounders.
320-510_006 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 62
Product Sheet | Detecon

Notification devices
Audible / visual, addressable

Loop Sounder / Beacon LSBX 005r WP Part no.: 912574


Analogue addressable Loop Sounder / Beacon for acoustic
and optical alarms with integrated dual isolator in red.
Addressing is done via integrated DIP switches.

Technical specifications Included in delivery


1 Loop Sounder / Beacon LSBX 005r WP
Enclosure material PC
IP rating IP 65
Not included in delivery
Technology / protocol Loop AP / XP95
Mounting hardware
Sound pressure up to 100 db
Enclosure colour red
Connection / mounting
Spherical cup colour red Cable recommendation standard
Integrated isolator yes J-Y(St)Y -2x2x0.8 mm, red 747180
-20 °C to +60 °C Recommended cable 2-wire
Operating temperature Conductor cross-section max. 2.5 mm2 (AWG 13)
(-4 °F to +140 °F)
Electrostatic shielding not required
Operating voltage 17 V - 28 V DC
Operating current siren 8 mA
Approvals / marking
Rated current consumption 333 µA
Weight 260 g (0.57 lbs)
104 x 97.5 mm (dia.xH)
Dimensions
4.09 x 3.84 inch (dia.xH)

Notice!
This combination must not be used for alerting and evacuation
The contents of this publication are subject to modifications without notice. All rights reserved.

of people in fire detection or gas extinguishing systems.


The device is not EN 54-23 or VdS approved.
320-510_007 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 63
Product Sheet | Detecon

Notification devices
Audible / visual, addressable

Base Sounder / Beacon BSBX 334 Part no.: 912584


Detector Base Sounder / Beacon with integrated dual
isolator. Addressing is done via integrated DIP switches.

Included in delivery
Technical specifications
1 Base Sounder / Beacon BSBX 334
Enclosure material PC 1 Addressing card
Sound pressure up to 85 dB
Enclosure colour white Not included in delivery
Flashlight circle colour clear Mounting hardware
Integrated isolator yea
-20 °C to +60 °C Connection / mounting
Operating temperature
(-4 °F to +140 °F) Cable recommendation standard
Operating voltage 17 V - 28 V DC J-Y(St)Y -2x2x0.8 mm, red 747180
Recommended cable 2-wire
Operating current siren 8 mA Conductor cross-section max. 2.5 mm2 (AWG 13)
Rated current consumption 300 µA Electrostatic shielding not required
Weight 160 g (0.35 lbs)
115 x 38 mm (dia.xH) Approvals / marking
Dimensions
4.53 x 1.49 inch (dia.xH)
G 207103

Notice!
No approval according to EN 54-23
VdS approval based only on
The contents of this publication are subject to modifications without notice. All rights reserved.

EN 54-3 for sounders.


320-510_018 / AI00_2016en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 64
Product Sheet | Detecon

Notification devices
Audible / visual

LWA-90 red RNB lighted warning display Part no.: 910178


Illuminated warning display with super bright LEDs in a
profile aluminium housing with RNB standard text on the
reverse side of printed front window and two end caps for
lateral cable insertion. Very bright and homogeneous
illumination of the printed surface via use of a light guide
body and laterally radiating super bright LEDs. The light
display can be configured to flashing or continuous light via
DIP switch and the built-in buzzer turned on or off.t

Technical specifications Product features


• Standard text, „Achtung! Raum nicht betreten
Operating voltage 21 V - 29 V DC
Löschung ausgelöst“ (RNB)
Rated voltage 24 V DC
• The warning display is maintenance-free
75 mA (continuous light)
Rated current consumption 55 mA (flashing) • DIP switch for configuring continuous or flashing light
+10 mA (for buzzer) • Buzzer activation (approx. 70 dB)
Light colour red • Optional relay contact to activate an external signal
240 x 90 mm (WxH) generator
Light surface
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C Included in delivery
Operating temperature
(-40 °F to +104 °F)
1 LWA-90 lighted warning display, red RNB,
Enclosure material Aluminium, black without mounting hardware
IP rating IP 50
Weight 993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
Dimensions
11.8 x 4.7 x 1.4 inch (WxHxD)

LWA-90 IP 54 red RNB lighted warning Part no.: 911746


display IP rating IP 54
Otherwise like part no. 910178
Technical specifications
Weight 1000 g (2.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_008 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 65
Product Sheet | Detecon

Notification devices
Audible / visual

LWA-90 red RV lighted warning display Part no.: 910179


Illuminated warning display with super bright LEDs in a
profile aluminium housing with RV standard text on the
reverse side of printed front window and two end caps
for lateral cable insertion. Very bright and homogeneous
illumination of the printed surface via use of a light guide
body and laterally radiating super bright LEDs. The light
display can be configured to flashing or continuous light
via DIP switch and the built-in buzzer turned on or off.

Technical specifications Product features


• Standard text „Achtung! Raum verlassen
Operating voltage 21 V - 29 V DC
Löschung ausgelöst“ (RV)
Rated voltage 24 V DC
• The warning display is maintenance-free
75 mA (continuous light)
Rated current consumption 55 mA (flashing) • DIP switch for configuring continuous or flashing light
+10 mA (for buzzer) • Buzzer activation (approx. 70 dB)
Light colour red • Optional relay contact to activate an external signal
240 x 90 mm (WxH) generator
Light surface
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C Included in delivery
Operating temperature
(-40 °F to +104 °F)
1 LWA-90 lighted warning display, red RNB,
Enclosure material Aluminium, black
without mounting hardware
IP rating IP 50
Weight 993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
Dimensions
11.8 x 4.7 x 1.4 inch (WxHxD)

LWA-90 IP 54 red RV lighted warning Part no.: 916293


display IP rating IP 54
Otherwise like part no. 910179
Technical specifications
Weight 1000 g (2.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_009 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 66
Product Sheet | Detecon

Notification devices
Audible / visual

LWA-90 red RSV lighted warning display Part no.: 910180


Illuminated warning display with super bright LEDs in a
profile aluminium housing with RSV standard text on the
reverse side of printed front window and two end caps
for lateral cable insertion. Very bright and homogeneous
illumination of the printed surface via use of a light guide
body and laterally radiating super bright LEDs. The light
display can be configured to flashing or continuous light
via DIP switch and the built-in buzzer turned on or off.

Technical specifications Product features


• Standard text „Achtung! Raum sofort verlassen
Operating voltage 21 V - 29 V DC
Löschung ausgelöst“ (RSV)
Rated voltage 24 V DC
• The warning display is maintenance-free
75 mA (continuous light)
Rated current consumption 55 mA (flashing) • DIP switch for configuring continuous or flashing light
+10 mA (for buzzer) • Buzzer activation (approx. 70 dB)
Light colour red • Optional relay contact to activate an external signal
240 x 90 mm (WxH) generator
Light surface
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C Included in delivery
Operating temperature
(-40 °F to +104 °F)
1 LWA-90 lighted warning display, red RSV,
Enclosure material Aluminium, black
without mounting hardware
IP rating IP 50
Weight 993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
Dimensions
11.8 x 4.7 x 1.4 inch (WxHxD)

LWA-90 IP 54 red RSV lighted warning Part no.: 916294


display IP rating IP 54
Otherwise like part no. 910180
Technical specifications
Weight 1000 g (2.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_010 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 67
Product Sheet | Detecon

Notification devices
Audible / visual

LWA-90 red KT lighted warning display Part no.: 910181


Illuminated warning display with super bright LEDs in a
profile aluminium housing with optional custom text on
the reverse side of printed front window and two end caps
for lateral cable insertion. Very bright and homogeneous
illumination of the printed surface via use of a light guide
body and laterally radiating super bright LEDs. The light
display can be configured to flashing or continuous light
via DIP switch and the built-in buzzer turned on or off.

Technical specifications Product features


• Custom text: Any text or graphic can be chosen!
Operating voltage 21 V - 29 V DC
• The warning display is maintenance-free
Rated voltage 24 V DC
• DIP switch for configuring continuous or flashing light
75 mA (continuous light)
Rated current consumption 55 mA (flashing) • Buzzer activation (approx. 70 dB)
+10 mA (for buzzer) • Optional relay contact to activate an external signal
Light colour red generator
240 x 90 mm (WxH)
Light surface
9.4 x 3.5 inch (WxH)
Included in delivery
-40 °C to +85 °C
Operating temperature 1 LWA-90 lighted warning display, red KT,
(-40 °F to +104 °F)
without mounting hardware
Enclosure material Aluminium, black
IP rating IP 50
Weight 993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
Dimensions
11.8 x 4.7 x 1.4 inch (WxHxD)

LWA-90 IP 54 red KT lighted warning Part no.: 911747


display IP rating IP 54
Otherwise like part no. 910181
Technical specifications
Weight 1000 g (2.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_011 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 68
Product Sheet | Detecon

Notification devices
Audible / visual

LWA-130 red KT lighted warning display Part no.: 910182


Illuminated warning display with super bright LEDs in a
profile aluminium housing with optional custom text on
the reverse side of printed front window and two end caps
for lateral cable insertion. Very bright and homogeneous
illumination of the printed surface via use of a light guide
body and laterally radiating super bright LEDs. The light
display can be configured to flashing or continuous light
via DIP switch and the built-in buzzer turned on or off.

Technical specifications Product features


• Custom text: Any text or graphic can be chosen!
Operating voltage 21 V - 29 V DC
• The warning display is maintenance-free
Rated voltage 24 V DC
• DIP switch for configuring continuous or flashing light
75 mA (continuous light)
Rated current consumption 55 mA (flashing) • Buzzer activation (approx. 90 dB)
+10 mA (for buzzer) • Optional relay contact to activate an external signal
Light colour red generator
240 x 130 mm (WxH)
Light surface
9.4 x 3.5 inch (WxH)
Included in delivery
-40 °C to +85 °C
Operating temperature
(-40 °F to +104 °F)
1 LWA-130 lighted warning display, red KT,
without mounting hardware
Enclosure material Aluminium, black
IP rating IP 50
Weight 1395 g (3.1 lbs)
346 x 166 x 35 mm (WxHxD)
Dimensions
13.6 x 6.5 x 1.4 inch (WxHxD)

LWA-130 IP 54 red KT lighted warning Part no.: 911748


display IP rating IP 54
Otherwise like part no. 910182
Technical specifications
Weight 1403 g (3.09 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_012 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 69
Product Sheet | Detecon

Notification devices
Audible / visual

V2A base for LWA-90/-130 Part no.: 910185


For preassembly of the LWA-90/-130 lighted warning displays.

Included in delivery
Technical specifications
1 Base V2A
Material V2A 3 Countersunk screws and dowels
280 x 110 x 11 mm (WxHxD) 2 Screws M4 x 20 mm
Dimensions
11 x 4.3 x 0.4 inch (WxHxD)

V2A head cover for LWA-90/-130 Part no.: 910184


Weather protection for the LWA-90/-130 lighted warning

Included in delivery
Technical specifications
V2A head cover without mounting hardware
Material V2A
Weight 760 g (1.7 lbs)
340 (cover), 300 (rear panel)
x 120 x 95 mm (WxHxD)
Dimensions
13.4 (cover), 11.5 (rear panel)
x 4.7 x 3.7 inch (WxHxD)

IP 65 LWA-90 weatherproof housing Part no.: 910186


Weatherproof housing of transparent acrylic for use of
LWA-90 lighted warning display. Consisting of rear panel and
housing upper part, preassembled base bottom section for
The contents of this publication are subject to modifications without notice. All rights reserved.

receiving the lighted warning display.

Included in delivery
Technical specifications
IP 65 housing without mounting hardware
Enclosure material Acryl
Weight 1895 g (4.2 lbs) Note
350 x 150 x 65 mm (WxHxD) To obtain an IP 65 rating, the standard illuminated
320-510_013 / AI00_2015en

+ overhang 40 mm warning signals (IP 50) can be used in combination with


Dimensions
13.8 x 5.9 x 2.6 inch (WxHxD)
the weather-proof housing. Illuminated warning signals
+ overhang 1.6 inch
with an IP 54 rating are not necessary in this case.

1/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 70
Product Sheet | Detecon

Notification devices
Audible / visual

IP 65 LWA-130 weatherproof housing Part no.: 910187


Weatherproof housing of transparent acrylic for use of
Technical specifications LWA-130 lighted warning display.
Weight 2459 g (5.4 lbs) Otherwise like part no.: 910186
400 x 200 x 65 mm (WxHxD)
+ overhang 40 mm
Dimensions Note
15.8 x 7.9 x 2.6 inch (WxHxD)
+ overhang 1.6 inch To obtain an IP 65 rating, the standard illuminated
warning signals (IP 50) can be used in combination with
the weather-proof housing. Illuminated warning signals
with an IP 54 rating are not necessary in this case.
The contents of this publication are subject to modifications without notice. All rights reserved.
320-510_013 / AI00_2015en

2/2
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 71
Product Sheet | Detecon

Notification devices
Audible / visual, Ex

Sounder / Beacon YL60 MX Ex Part no.: 910657


Audible and visual alarm device for signalling danger of fire
that is especially suitable for use in industrial environments
with hazard areas in zone 1 as well as 21. Equipped with
electronic module for operation directly on a primary control
group of the fire alarm panel via a voltage increase.
The robust aluminium housing is resistant to sea water,
environmental effects and chemicals.

Product features Included in delivery


• Explosion-proof device for 1 Sounder / Beacon YL60 MX Ex
hazardous zone 1 as well as 21 1 Dust cover
• Max. 110 dB (A) / 1 m omnidirectional sound output 1 Blanking plug
• 32 standardised tone sequences selectable
• 2-stage alarm, independently selectable 2nd stage Not included in delivery
• Tone selection via DIL switch Mounting hardware
• Fitted as standard with protective cage
Connection / mounting
Recommended cable 2-wire
Conductor cross-section: 2.5 mm2 (AWG 13)
Technical specifications
Spherical calotte material PC, red
Note
Horn material ABS, red
The combination unit can be operated via the voltage
Enclosure material Aluminium, red increase function as well as via the voltage reversal function
IP rating IP 66 at the FMZ 5000 and FMZ 5000 mod S control panels. The
device has an integrated reverse polarity protection diode.
-35 °C to +60 °C (T4 / T135°C)
(-31 °F to +140 °F (T4 / T135°C))
Operating temperature
-35 °C to +40 °C (T6 / T85°C) Approvals / marking
(-31 °F to +104 °F (T6 / T85 °C))
Ex classification: x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
-35 °C to +60 °C
Storage temperature x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
(-31 °F to +140 °F)
x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP 66
Rated voltage 24 V DC
x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP 66
Operating voltage 18 V - 30 V DC
The contents of this publication are subject to modifications without notice. All rights reserved.

Rated current consumption approx. 570 mA


Power consumption 13.7 W
Flash energy 5J
Flash rate 1 Hz = 60 flashes / min.
Tones 32
Sound pressure up to 110 dB (A) 1 m
Relative humidity max. 95%
Weight 6000 g (13.2 lbs)
420 x 145 mm (HxD)
Dimensions
320-520_001 / AI00_2015en

16.5 x 5.7 inch (HxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 9 - 72
Product Sheet | Detecon

Door hold - open technique


Door hold - open technique

TSZ 5000 Part no.: 909292


The magnetic door holder panel TSZ 5000 is intended
for the control of classified fire doors, fire gates and fire
dampers by means of hold - open devices.
If a fire detector should detect smoke or if a manual call
point is activated, the TSZ 5000 interrupts the power supply
to the holding solenoids immediately, and the fire doors are
automatically closed by the door closer. Simultaneously, the
relay contact opens and possibly connected signal devices
or controls are activated.

Product features Included in delivery


• Power output for hold-open devices 1 Door lock panel TSZ 5000
• Floating detector contacts for fault and alarm 1 Cable gland M20x1.5
3 Cable glands M16x1.5
• Automatic door locking, opening of smoke dampers, 1 Dummy plug M20x1.5
disconnection of machines 3 Dummy plugs M16x1.5
4 Screws 3.5x35 and dowel pins

Technical specifications Approvals / marking


-10 °C to +40 °C
Operating temperature Z-6.5-2067
(+14 °F to +104 °F)
Operating voltage 100 V - 260 V AC
Rated voltage 24 V DC
Power rating 10 W
Relay contact voltage 30 V DC
IP rating IP 64
Relative humididy max. 95 %
Enclosure material Plastics
Enclosure colour light grey, RAL 7035
Weight 550 g (1.2 lbs)
160 x 130 x 60 mm (WxHxD)
Dimensions
6.3 x 5.1 x 2.4 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.
350-010_001/ AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 10 - 1
Product Sheet | Detecon

Door hold - open technique


Door hold - open technique

Holding solenoid 490 N / base plate Part no.: 909327


The holding solenoid with its base plate can be used
for wall mounting. The standard electric connection
occurs via double-pole terminals.

Product features
• Integrated reverse protection diode and suppressor diode

Technical specifications Approvals / marking


Rated voltage 24 V DC
G 212043 0786-CPD-20249
Rated current 63 mA
Wattage rating 1.5 W
Adhesive force 490 N
0 °C to + 50 °C
Operating temperature
(+32 °F to +122 °F)
-30 °C to +70 °C
Storage temperature
(-22 °F to +158 °F)
Duty cycle 100 %
Holding solenoid diameter 50 mm (2 inch)
IP rating IP 65
Weight 400 g (0.9 lbs)
65 x 93 x 33 mm (WxHxD)
Dimensions
2.6 x 3.7 x 1.3 inch (WxHxD)

Holding solenoid 490 N / housing with Part no.: 909328


pushbutton The holding solenoid with its steel base plate in a closed
housing is a surface-mount design and can be used for
wall mounting. An interrupt button is integrated, and the
electric connection is carried out from the rear side.

Product features
• Incorporated reverse protection diode
and suppressor diode

Approvals / marking
The contents of this publication are subject to modifications without notice. All rights reserved.

Technical specifications
Rated voltage 24 V DC
G 212043 0786-CPD-20249
Rated current 63 mA
Wattage rating 1.5 W
Adhesive force 490 N
0 °C to +50 °C
Operating temperatur
(+32 °F to +122 °F)
-30 °C to +70 °C
Storage temperature
(-22 °F to +158 °F)
Duty cycle 100 %
Holding solenoid diameter 50 mm (2 inch)
350-010_002 / AI00_2015en

IP rating IP 65
Weight 450 g (1 lbs)
85 x 105 x 37,5 mm (WxHxD)
Dimensions
3.4 x 4.1 x 1.5 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 10 - 2
Product Sheet | Detecon

Door hold - open technique


Door hold - open technique

Holding solenoid 490 N / length 185 mm Part no.: 909329


(7.3 inch) Through modification the holding solenoid can be used for
wall, ceiling or floor mounting. The tube can be shortened to
110 and/or 145 mm (floor/wall mounting) so that almost any
kind of distance between door and wall can be bridged.

Product features
• Incorporated reverse protection diode
and suppressor diode

Technical specifications
Approvals / marking
Rated voltage 24 V DC
Rated curren 63 mA
G 212043 0786-CPD-20249
Wattage rating 1.5 W
Adhesive force 490 N
0 °C to +50 °C
Operating temperature
(+32 °F to +122 °F)
-30 °C to +70 °C
Storage temperature
(-22 °F to +158 °F)
Duty cycle 100 %
Holding solenoid diameter 50 mm (2 inch)
IP rating IP 65
Weight 820 g (1.8 lbs)
90 x 185 x 105 mm (WxHxD)
Dimensions
3.5 x 7.3 x 4.1 inch (WxHxD)

Holding solenoid 490 N / length 335 mm Part no.: 909330


(13.2 inch)

Technical specifications
Weight 900 g (2 lbs) Otherwise like part no. 909329
90 x 335 x 105 mm (WxHxD)
Dimensions
3.5 x 13.2 x 4.1 inch (WxHxD)

Anchor plate flexible design Part no.: 909411


Anchor plate with flexible connecting piece for establishing
The contents of this publication are subject to modifications without notice. All rights reserved.

the magnetic connection between fire door and door holding


solenoid. In general, the diameter of the anchor plate is
slightly larger than that of the corresponding holding solenoid.
Thus, mounting imprecision does not have any effect on the
adhesive force.

Product features
Technical specifications • Compensating inclination angle up to 5 °C (+41 °F)
0 °C to +50 °C • With rubber bearing
Operating temperature
(+32 °F to +122 °F)
-30 °C to +70 °C
Storage temperature
350-010_003 / AI00_2015en

(-22 °F to +158 °F)


Plate diameter 55 mm (2.2 inch)
Weight 200 g (0.4 lbs)
55 x 55 x 18 mm (WxHxD)
Dimensions
2.2 x 2.2 x 0.7 inch (WxHxD)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 10 - 3
Product Sheet | Detecon

Door hold - open technique


Door hold - open technique

Anchor plate with hinged joint Part no.: 909412


Anchor plate with flexible connecting piece and hinged joint
for establishing the magnetic connection between fire door
and door holding solenoids. In general, the diameter of the
anchor plate is slightly larger than that of the corresponding
holding solenoid. Thus, mounting imprecision does not have
any effect on the adhesive force.

Product features
• Pivoting in two directions up to 60 °C (+140 °F)
Technical specifications
• Fixable in any position
0 °C to +50 °C
Operating temperature
(+32 °F to +122 °F)
-30 °C to +70 °C
Storage temperature
(-22 °F to +158 °F)
Plate diameter 55 mm (2.2 inch)
Weight 180 g (0.4 lbs)
55 x 55 x 50 mm (WxHxD)
Dimensions
2.2 x 2.2 x 2 inch (WxHxD)

Hand switch for magnetic door holder Part no.: 909413


system, surface-mount Push-button of surface-mount design for manual activation
of locking systems with the inscription „Tür schließen!“.

Note
Only these push-button are suitable for operation in
locking systems according to DiBt

Technical specifications
0°C to +50°C
Operating temperature
(+32 °F to +122 °F)
Enclosure material Plastics
Weight 270 g (0.6 lbs)
62.5 x 62.5 x 37 mm (WxHxD)
Dimensions
2.5 x 2.5 x 1.5 inch (WxHxD)
The contents of this publication are subject to modifications without notice. All rights reserved.

Hand switch for magnetic door holder Part no.: 909414


system, flush mounting Push-button of flush-mounted design for manual activation
of locking systems with the inscription „Tür schließen!“.

Note
Only these push-button are suitable for operation in
locking systems according to DiBt

Technical specifications
350-010_004 / AI00_2015en

0°C to +50°C
Operating temperature
(+32 °F to +122 °F)
Enclosure material Plastics
Weight 200 g (0.4 lbs)
81 x 81 x 45 mm (WxHxD)
Dimensions
3.2 x 3.2 x 1.8 inch (WxHxD)
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 10 - 4
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Fire alarm cable FireLine 750, red Special fire alarm cable (red, halogen-free) for signal
transmission in facilities in dry and moist locations.
For fixed cable installations.

Quantity unit for orders = metres

Included in delivery
Batch size as required: cable coil or cable drum
Technical specifications
Cable shielding Aluminium foil, drain wire Note
This cable type must not be used in areas in where a function
IEC 60654
Halogen-free according
(non-corrosive fire gases)
integrity according to VDE DIN 4102-12/E30 is required.

IEC 60332-1-2
Flame-retardant according
IEC 60332-3-22
Fire-resistant according IEC 60331-21
UV-protected according IEC 60068-2-5
Smoke emission according IEC 61034
during installation R=6xD
Min. bending radius
fixed installation R=4xD
-40 °C up to +70 °C
Temperature range
(+40 °F up to +158 °F)
Min. installation temperature -15 °C (5 °F)
Batch number, cable type / diameter,
Cable identification manufacturing month /-year,
manufacturer name, lenght marking

Number of conductors Weight


Outer diameter Capacity Loop inductance
Designation Part no. & cross-section approx. kg/km
approx. mm (inch) nF / km (0.62 miles) mH / km (0.62 miles)
n x mm2 (AWG) (lbs / 0.62 miles)
906331 2 x 1.0 (AWG 17) 7.5 (0.3) 80 (176.4) 70 0.67
906333 2 x 1.5 (AWG 15) 8.0 (0.3) 95 (209.4) 80 0.68
906335 2 x 2.5 (AWG 13) 9.5 (0.4) 135 (297.6) 87 0.63
906337 3 x 1.0 (AWG 17) 7.9 (0.3) 90 (198.4) 70 0.67
906339 3 x 1.5 (AWG 15) 8.5 (0.3) 110 (242.5) 80 0.68
906341 3 x 2.5 (AWG 13) 9.8 (0.4) 155 (341.7) 87 0.63
906343 4 x 1.0 (AWG 17) 8.5 (0.3) 105 (231.5) 70 0.67
The contents of this publication are subject to modifications without notice. All rights reserved.

906345 4 x 1.5 (AWG 15) 9.2 (0.4) 130 (286.6) 80 0.68


906347 4 x 2.5 (AWG 13) 10.6 (0.4) 185 (407.8) 87 0.63
FireLine 750 906349 7 x 1.0 (AWG 17) 10.0 (0.4) 150 (330.7) 70 0.67
906351 7 x 1.5 (AWG 15) 11.0 (0.4) 195 (429.9) 80 0.68
906493 7 x 2.5 (AWG 13) 12.6 (0.5) 280 (617.3) 87 0.63
907404 12 x 1.0 (AWG 17) 13.0 (0.5) 240 (529.1) 70 0.67
906494 12 x 1.5 (AWG 15) 14.2 (0.6) 305 (672.4) 80 0.68
906495 12 x 2.5 (AWG 13) 16.8 (0.7) 450 (992.1) 87 0.63
907981 19 x 1.0 (AWG 17) 15.5 (0.6) 340 (749.6) 70 0.67
906496 19 x 1.5 (AWG 15) 16.5 (0.6) 450 (992.1) 80 0.68
906497 19 x 2.5 (AWG 13) 20.0 (0.8) 680 (1499.1) 87 0.63
520-010_001 / AI00_2015en

908512 3 x 1.5 S* (AWG 15) 8.5 (0.3) 110 (242.5) 80 0.68


*Special colour code: black, blue, green yellow

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 1
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Fire alarm cable FireLine E 30, red Special fire alarm cable (red, halogen-free) with function
integrity E 30 according EN 50288-7 for signal transmission
in facilities in dry and moist locations.
For fixed cable installations.

Quantity unit for orders = metres

Included in delivery
Technical specifications Batch size as required: cable coil or cable drum

Lead identification DIN VDE 0293-308:01/2003-01


Note
System circuit integrity VDE DIN 4102-12/E30
The function integrity E 30 can be reached in combination
Cabel shielding Aluminium foil, drain wire with suitable assambly materials and correct installation only.
IEC 60654-1
Halogen-free according and IEC 60754-2
(non-corrosive fire gases) Approvals / marking
IEC 60332-1-2
Flame-retardant according
IEC 60332-3-22
Fire-resistant according IEC 60331-21
UV-protected according IEC 60068-2-5
Smoke emission according IEC 61034-2
during installation R=6xD
Min. bending radius
fixed installation R=4xD
-40 °C up to +70 °C
Temperature range
(+40 °F up to +158 °F)
Min. installation temperature -15 °C (+5 °F)
Batch number cable type / diameter,
Cable identification manufacturing month /-year,
manufacturer name, lenght marking

Number of conductors Weight


Outer diameter Capacity Loop inductance
Designation Part no. & cross-section approx. kg/km
approx. mm (inch) nF / km (0.62 miles) mH / km (0.62 miles)
n x mm2 (AWG) (lbs/ 0.62 miles
906332 2 x 1.0 (AWG 17) 7.9 (0.3) 91 (200.6) 70 0.67
906334 2 x 1.5 (AWG 15) 9.3 (0.3) 125 (275.6) 80 0.68
906336 2 x 2.5 (AWG 13) 11.1 (0.4) 180 (396.8) 87 0.63
906338 3 x 1.0 (AWG 17) 9.3 (0.3) 120 (264.5) 70 0.67
906340 3 x 1.5 (AWG 15) 9.8 (0.4) 144 (317.5) 80 0.68
The contents of this publication are subject to modifications without notice. All rights reserved.

917816 3 x 2.5 (AWG 13) 11.8 (0.4) 209 (460.7) 87 0.63


906344 4 x 1.0 (AWG 17) 10.0 (0.4) 139 (306.4) 70 0.67
906346 4 x 1.5 (AWG 15) 10.8 (0.4) 171 (376.9) 80 0.68
906348 4 x 2.5 (AWG 13) 13.0 (0.5) 252 (555.5) 87 0.63
FireLine E30 906350 7 x 1.0 (AWG 17) 12.0 (0.5) 207 (456.3) 70 0.67
906352 7 x 1.5 (AWG 15) 12.8 (0.5) 270 (595.2) 80 0.68
907403 7 x 2.5 (AWG 13) 15.6 (0.6) 382 (842.1) 87 0.63
907405 12 x 1.0 (AWG 17) 15.9 (0.6) 334 (736.3) 70 0.67
907408 12 x 1.5 (AWG 15) 17.1 (0.7) 417 (919.3) 80 0.68
907409 12 x 2.5 (AWG 13) 20.9 (0.8) 603 (1329.4) 87 0.63
520-010_002 / AI00_2015en

910887 19 x 1.0 (AWG 17) 18.7 (0.7) 481 (1060.4) 70 0.67


907410 19 x 1.5 (AWG 15) 20.1 (0.8) 600 (1322.7) 80 0.68
907431 19 x 2.5 (AWG 13) 24.7 (0.9) 919 (2026.0) 87 0.63
906342 3 x 1.5 S* (AWG 15) 9.8 (0.4) 144 (317.5) 80 0.68
*Special colour code: black, blue, green yellow
1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 2
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Cable J-Y(St)Y - 2x2x0.8 mm (0.03 inch) Ø, Part no.: 747180


red Fire alarm cable (red) for signal transmission in facilities
in dry and moist plant locations. For installation inside
and on wall.

Quantity unit for orders = metres

Technical specifications Included in delivery


1 Packaging unit (cable coil 200m (0.12 miles))
Line resistance at 20 °C (68 °F) ≤ 36.6 Ohm / km (0.6 miles)
Isolating resistance
≥ 100 MOhm / km (0.6 miles)
at 20 °C (68 °F)
Operating capacity at 800 Hz ≤ 120 nF / km (0.6 miles)
Capacitive couplings at 800 Hz ≤ 500 pF / km (0.6 miles)
Inductance at 800 Hz approx. 0.7 mH / km (0.6 miles)
≤ 300 V,
Operating voltage
not for high-voltage applications
Temperature range for -30 °C to +70 °C
fixed installation (-22 °F to +158 °F)
Temperature range for -5 °C to +50 °C
flexible installation (+23 °F to +123 °F)
Outer diameter 6 mm (0.2 inch)
Specification according to VDE 0815
Weight approx. 57 g / m (0.1 lbs / 39 inch)

Cable JE-H(St)H - 2x2x0.8 mm (0.03 inch) Ø, Part no.: 907940


orange
Fire alarm cable (orange) with E 30 circuit integrity
for signal transmission in facilities in dry and moist
plant locations. For installation in and on wall.

Fire detection in accordance with VDE 0482 Part 266-2,


DIN EN 50266-2/ IEC 60332-3 (corresponds to
DIN VDE 0472 Part 804 test method C).
Technical specifications E 30: circuit integrity in accordance with DIN 4102 Part 12
Line resistance at 20 °C (68 °F) ≤ 36.6 Ohm / km (0.6 miles)
Leads are only stranded as star quad, not in pairs
Isolating resistance
≥ 100 MOhm / km (0.6 miles)
The contents of this publication are subject to modifications without notice. All rights reserved.

at 20 °C (68 °F)
Quantity unit for orders = metres
Operating capacity at 800 Hz ≤ 120 nF / km (0.6 miles)
Capacitive couplings at 800 Hz ≤ 200 pF / 100m (0.06 miles)
Included in delivery
Inductance at 800 Hz approx. 0.7 mH / km (0.6 miles) 1 Packaging unit (cable coil 100 m (0.06 miles))
≤ 225 V,
Operating voltage
not for high-voltage applications
Temperature range for -30 °C to +70 °C
fixed installation (-22 °F to +158 °F)
Temperature range -5 °C to +50 °C
for flexible installation (+23 °F to +122 °F)
Outer diameter 7.5 mm (0.3 inch)
520-010_003 / AI00_2015en

Minimum bending radius 6 x cables Ø


Specification according to VDE 0815
Weight approx. 74 g / m (0.2 lbs / 39 inch)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 3
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Cable LiYCY - 5 x 0.5 mm2 Part no.: 606061


(AWG 20), shielded Data cable (grey)

Quantity unit for orders = meters

Included in delivery
1 Packaging unit (cable coil 100 m (0.06 miles))
Technical specifications
Line resistance at 20 °C (68 °F) ≤ 39 Ohm / km (0.6 miles)
Isolating resistance
≥ 20 MOhm / cm (0.4 inch)
at 20 °C (68 °F)
Operating capacity
- lead/lead ≤ 120 nF / km (0.6 miles)
- lead/shield ≤ 160 nF / km (0.6 miles)
Inductance approx. 0.65 mH / km (0.6 miles)
≤ 250 V,
Operating voltage
not for high-voltage applications
Temperature range for -30 °C to +80 °C
fixed installation (-22 °F to +176 °F)
Outer diameter 7 mm (0.3 inch)
Specification according to VDE 0812
Weight approx. 68 g / m (0.2 lbs / 39 inch)

Cable JE-Y(St)Y - 2x2x0.8 mm (0.03 inch) Ø, Part no.: 902674


blue Ex Fire alarm cable (blue) for signal transmission in facilities in
dry and moist plant locations. For installation in and on wall.

Quantity unit for orders = meters

Technical specifications Included in delivery


1 Packaging unit (cable coil 200 m (0.12 miles))
Line resistance at 20 °C (68 °F) ≤ 36.6 Ohm / km (0.6 miles)
Isolating resistence
≥ 100 MOhm / km (0.6 miles)
at 20 °C (68 °F)
Operating capacity ≤ 100 nF / km (0.6 miles)
The contents of this publication are subject to modifications without notice. All rights reserved.

≤ 225 V,
Operating voltage
not for high-voltage applications
Temperature range for -30 °C to +70 °C
fixed installation (-22 °F to +158 °F)
Temperature range for -5 °C to +50 °C
flexible installation (-22 °F to +158 °F)
Outer diameter 6.6 mm (0.3 inch)
Minimum bending radius 6 x cables Ø
Specification according to VDE 0815
Weight approx. 60 g / m (0.1 lbs / 39 inch)
520-010_004 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 4
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Cable OB-BL-PAAR-CY 2x2x0.5 mm2 Part no.: 920326


(AWG 20), blue Ex Fire alarm cable (blue) for signal transmission in
hazardous areas facilities in dry and moist plant locations.
For installation in and on wall.

Quantity unit for orders = meters

Technical specifications Included in delivery


1 Packaging unit (1 cable reel a 500 m (1640 foot))
Line resistance at 20 °C (68 °F) ≤ 37.8 Ohm / km (0.6 miles) Other lengths available on request
Isolating resistence
≥ 20 MOhm / km (0.6 miles)
at 20 °C (68 °F)
Operating capacity
- lead/lead ≤ 105 nF / km (0.6 miles)
- lead/shield ≤ 145 nF / km (0.6 miles)
Inductance approx. 0,68 mH / km (0.6 miles)
900 V,
Operating voltage
not for high-voltage applications
Temperature range for -30 °C to +80 °C
fixed installation (-22 °F to +176 °F)
Temperature range for -10 °C to +80 °C
flexible installation (-14 °F to +176 °F)
Outer diameter 7.6 mm (0.3 inch)
flexing R = 10 x D
Minimum bending radius
fixed R = 5 x D
Specification according to VDE 0165
Weight approx. 90 g / m (0.2 lbs / 39 inch)
The contents of this publication are subject to modifications without notice. All rights reserved.
520-010_005 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 5
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Cable gland M16/M20x1.5Ms Part no.: 907096


Easily installed cable gland with large sealing and terminal
connection area for wide cable diameters. Can be used as
EMC cable gland, with integrated strain relief and anti-twist
protection. To replace the standard M16 cable glands on the
UniVario detector base for M20 installations.

Included in delivery
Cable gland M 16 / M 20 x 1,5 MS

Not included in delivery


Cold-shrink tube, silicone, 25 > 6 mm (1 > 0.2 inch) 905337
Gland M 16 x 1.5 Ms  901861

Technical specifications
Brass, nickel-plated
Material
Viton sealing ring and O-ring
Connection thread M16 x 1.5
Terminal connection area 9 - 13 mm (0.4 -0.5 inch)
Protection rating IP 68 (5 bar)
-20 °C to +100 °C
Ambient temperature
(-4 °F to +212 °F)
Weight 34 g (0.1 lbs)

Cold-shrink tube 25 > 6 mm (1 > 0.2 inch) Part no.: 905337


Cold-shrink tube for installation of detectors or electrical
devices in outdoor areas, in shipbuilding or for demanding
sealing requirements, such as in machine tools.
Easy installation, without tools. Reliable, durable sealing
without heat application. Moisture resistance and resistance
to acids, alkalis, ozone and UV. Non-flammable.

Included in delivery
Cold-shrink tube, silicone, 25 > 6 mm (1 > 0.2 inch)
The contents of this publication are subject to modifications without notice. All rights reserved.

Note
Technical specifications
The installation of the shrink tube is irreversible
Material Silicone rubber
Cable diameter 6 to 25 mm (0.2 to 1 inch)
Colour black
-55 °C to +260 °C
Operating temperature
(-67 °F to +500 °F)
Length 125 mm (4.9 inch)
Weight 11 g (0.02 lbs)
520-010_007 / AI00_2015en

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 6
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Cable gland M20x1.5 MS with twin insertion Part no.: 887705

Technical specifications
Material Brass, nickel-plated
Terminal connection area 2 x Ø 6 mm (0.2 inch)
-20 °C to +100 °C
Operating temperature
(-4 °F to +212 °F)
Weight 31 g (0.07 lbs)

Not included in delivery


Gland M 20 x 1.5 PA 801722

Cable gland M20x1.5 Ms with twin insertion Part no.: 908690

Technical specifications
Terminal connection area 2 x Ø 8 mm (0.3 inch)

Otherwise like part no. 887705

Cable gland M20x1.5 PA 6-3 with double Part no.: 886323


insertion
Technical specifications
Material Plastic, PA 6-3
Terminal connection area 2 x Ø 6 mm (0.2 inch)
-20 °C to +100 °C
Operating temperature
(-4 °F to +212 °F)
Weight 10 g (0.01 lbs)

Not included in delivery


Gland M 20 x 1,5 PA 801722

Cable gland M20x1.5 PA 6-3 with twin Part no.: 908751


insertion
Technical specifications
The contents of this publication are subject to modifications without notice. All rights reserved.

Terminal connection area 2 x Ø 8 mm (0.3 inch)

Otherwise like part no. 886323

Cable gland M20x1.5 Ex-d A4 NEW Part no.: 920793

Technical specifications
Material Stainless steel 1.4404
Terminal connection area Ø 7 - 12 mm
-60 °C to +105 °C
520-010_008 / AI01_2016en

Operating temperature
(-76 °F to +221 °F)
Certificate II 2G 1D Ex d IIC
Weight 45 g (0.10 lbs)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 7
Product Sheet | Detecon

Cable/installation material
Cable/installation material

Adapter M16 x1.5Ms Part no.: 908609


Adapter for cable glands

Included in delivery
1 Adapter M 16 x 1.5 MS
1 O-Ring Di 13 x 1.5 Viton

Technical specifications
Brass, nickel-plated
Material
Viton sealing ring and O-ring
Mail thread M16 x 1.5
Female thread NPT 1/2”
-55 °C to +120 °C
Ambient temperature
(-67 °F to +248 °F)
Weight 30 g (0.07 lbs)

Adapter M16 x1.5Ms - NPT 3/4“ Part no.: 908808

Included in delivery
Technical specifications 1 Adapter M 16 x 1.5 - NPT 3/4“ MS gal. Ni
Brass, nickel-plated 1 O-Ring Di 13 x 1.5 Viton
Material
Viton sealing ring and O-ring
Mail thread M16 x 1.5
Female thread NPT 3/4“
Wrench size 27
-55 °C to +120 °C
Ambient temperature
(-67 °F to +248 °F)
Weight 80 g (0.2 lbs)
The contents of this publication are subject to modifications without notice. All rights reserved.

Adapter M16 x1.5Ms - NPT 1“ Part no.: 908810

Technical specifications Included in delivery


1 Adapter M 16 x 1.5 - NPT 1“ MS gal. Ni
Brass, nickel-plated 1 O-Ring Di 13 x 1.5 Viton
Material
Viton sealing ring and O-ring
Mail thread M16 x 1.5
Female thread NPT 1“
Wrench size 32
-55 °C to +120 °C
Ambient temperature
(-67 °F to +248 °F)
520-010_009 / AI00_2015en

Weight 110 g (0.2 lbs)

1/1
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Chapter 11 - 8
Product Sheet | Detecon

Notes
The contents of this publication are subject to modifications without notice. All rights reserved.

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Product Sheet | Detecon

Notes
The contents of this publication are subject to modifications without notice. All rights reserved.

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Product Sheet | Detecon

Notes
The contents of this publication are subject to modifications without notice. All rights reserved.

© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Europe, Middle East & Africa

BENELUX CENTRAL & EASTERN EUROPE FRANCE


Hinmanweg 11d Industriestr. 10/12 Centre d’Affaires CESCOM
NL-7575 BE Oldenzaal D-23843 Bad Oldesloe 4, rue Marconi
The Netherlands Germany BP 25180
Tel.: +31 (0)541 573233 Tel.: +49 (0)4531 803 8087 F-57075 Metz Cedex 03
Fax: +31 (0)541 573234 Fax: +49 (0)4531 803 137 France
vikingnetherlands@viking-emea.com contact@viking-emea.com Tel.: +33 (0)800 10 29 23
Fax: +33 (0)800 88 70 46
vikingfrance@viking-emea.com

IBÉRICA ITALY MIDDLE EAST


Calle Picos de Europa 4A Via Pogliano, 26/a LOB 19 Office #2506
San Fernando de Henares I-20020 Lainate (MI) Post Box No. 17531
E-28830 Madrid Italy Jebel Ali Free Zone, Dubai
Spain Tel.: +39 02 932 851 1 United Arab Emirates
Tel.: +34 91 677 8352 Fax: +39 02 932 851 30 Tel.: +971 (0)4 8895 561
Fax: +34 91 677 8498 vikingitaly@viking-emea.com Fax: +971 (0)4 8895 562
vikingspain@viking-emea.com vikingdubai@viking-emea.com

NORDIC POLAND ROMANIA & BULGARIA


Staffans Väg 5 ul. Płaskowickiej Filipiny 46/33 17-19 Horia, Closca si Crisan St.
S-192 78 Sollentuna PL-02 778 Warsaw RO-075100 Otopeni - Ilfov
Sweden Poland Romania
Tel.: +46 (0)8 594 415 90 Tel.: +48 22 403 57 90 Tel.: +40 21 311 51 48
Fax: +46 (0)8 591 280 18 Fax: +48 22 403 57 69 Fax: +40 21 311 51 41
vikingsweden@viking-emea.com vikingpoland@viking-emea.com maucha@viking-emea.com

TURKEY UK & IRELAND


İnönü Cad. Sümer Sok. Unit 2 - Byram House, Newborn Court
Zitaş İş Merkezi D2 Blok K:5, D:12 Chapel Street
34742 Kozyatağı, Kadıköy, İstanbul Epworth DN9 1HQ
PC1.5.14.1/0316/en | Photo: Cover: Adobe Stock © pichitstocker

Turkey United Kingdom


T: +90 (0)216 403 18 00 Tel.: +44 (0)1427 871 000
F: +90 (0)216 403 18 03 Fax: +44 (0)1427 873 917
vikingturkey@viking-emea.com vikinguk@viking-emea.com

For further information,