Technical Compliance Statement

Two Pen Mechanical Chart Recorder


Two Pen Mechanical Chart Recorder to be used or Recording Static Pressure and
Temperature of Natural Gas having Sp. Gr.: 0.60 (Air=1). Detail Technical Specifications
are as follows:
Request Quotation from Silver Automation Instruments for Paper Recorder

S.L Description Manufacturer’s Reply


No.
Item Required Specifications
a. Case Die Cast Aluminium or Forged Steel
with a glass hinged door.
b. Type of Protection Weather Proof for outdoor
Installation
c. Chart Drive Mechanical Spring Wounded
d. Rotation 24 Hour and 7Days dual option.
Selectable switch
e. Chart Type 10” to 12” Circular, 100 Uniform
linear division chart
f. Pen Type Fiber tip disposable Pen
g. Static Pressure Helical Bourdon Tube. Connected
System through tubing to system piping
Material: Stainless Steel
h. Thermal System Consists of a spiral wound tube, a
capillary & a stainless steel bulb.

The bulb diameter should be 11/16”


or less

Connection Size: ¾” NPT Male


i. Mounting 2” DN pipe mounting arrangement
at the rear side.
j. Accuracy Static Pressure element: ± 1%
Temperature element: ± 1%
k. Static Pressure ¼” NPT Female or ½” NPT Female
Connection
l. Coating Standard
m. Cleaning Class Standard
Three Pen Recorder
Three Pen Recorder with the under mentioned accessories to be used for recording
differential pressure, static pressure and temperature of Natural Gas having Sp. Gr. : 0.60
(Air= 1). Other details are as follows:

S.L Description Manufacturer’s Reply


No.
Item Required Specifications
a. Case Die Cast Aluminium or Forged Steel
with a glass hinged door.
b. Type of Protection Weather Proof for outdoor
Installation
c. Chart Drive Mechanical Spring Wounded
d. Rotation 24 Hour
e. Chart Type 10” to 12” Circular, 100 Uniform
linear division chart
f. Pen Type Fiber tip disposable Pen
g. Static Pressure Helical Bourdon Tube. Connected
System through tubing to system piping
Material: Stainless Steel
h. Differential Pressure Bellows Type
System
i. Thermal System Consists of a spiral wound tube, a
capillary & a stainless steel bulb.
The bulb diameter should be 11/16”
or less
Connection Size: ¾” NPT Male
j. Mounting 2” DN pipe mounting arrangement
at the rear side.
k. Accuracy Static Pressure element: ± 1%
Temperature element: ± 1%
Bellows element: ± 0.5%
l. Static Pressure ¼” NPT Female or ½” NPT Female
Connection
m. Coating Standard
n. Bellows element ¼” NPT Female X ½” NPT Female
Connection Size: OR
½” NPT Female X ½” NPT Female
o. Cleaning Class Standard