Вы находитесь на странице: 1из 32

Reduced Voltage Motor Starters 1

October 2008

Reduced Voltage Contents

Motor Starters
Description Page
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Instructional Leaflets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Note: Supplement to Publication No. CA08102001E — Tab 39.

MV811 Open Soft Starter

CA03902002E For more information visit: www.eaton.com


2 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Contents Application Description


Description Page
The MV811 line of IT. Soft Starters is ONLN SS OXFDO1 H STOP

Type MV811, Intelligent Technologies designed to work with three-phase Monitoring

(IT.) Medium Voltage Soft Starters center grounded star (WYE) source PREV NEXT ENTER

Operation . . . . . . . . . . . . . . . 7 and medium voltage motors in a WYE


Catalog Number or Delta (3-lead) configuration. The
Selection . . . . . . . . . . . . . . . 8 starter uses Silicon Controlled Rectifiers
(SCRs) to control the voltage to soft
Product Selection . . . . . . . . . 9 start and soft stop the motor. After the
Options . . . . . . . . . . . . . . . . . 16 motor is started, internal run bypass ESC

Accessories . . . . . . . . . . . . . . 17 contactors close resulting in the motor


Renewal Parts . . . . . . . . . . . . 19 running across the line. The built-in Figure 1. Digital Interface Module (DIM)
Standards and solid-state overload protects the
Certifications . . . . . . . . . . . . 19 motor from overload conditions with The DIM can be removed from the
Instructional Leaflets . . . . . . 19 sophisticated algorithms that model MV811 and remote mounted. Kits are
true motor heating, resulting in better available to door mount the DIM,
Technical Data and enabling users to safely configure,
motor protection and fewer nuisance
Specifications . . . . . . . . . . . 20 commission, monitor and trouble-
trips. Advanced protective and diag-
Dimensions . . . . . . . . . . . . . . 23 nostic features reduce downtime. shoot the system at the electrical panel
without opening the enclosure door.
The MV811 has a unique inclusive This will help eliminate the possibility
design encasing the SCRs, power of an arc flash incident.
circuitry, run bypass contactors and
overload protection, minimizing Communications
required mounting space and installa-
tion time. The separate control module The MV811 has built-in communica-
provides mounting flexibility. tion capabilities through QC (Quick
Connect) Port. QCPort enables the
Each MV811 power pole is rated at up soft starter to be connected to a
to 420 amps at 2.5 kV. Two units wired variety of networks, including
in series provide ratings up to 420 DeviceNet™, EtherNet/Modbus,
Type MV811 Soft Starter amps at 5 kV; three units wired in EtherNet/IP and PROFIBUS. The
series provide ratings up to 420 advantage of QCPort is that multiple
amperes at 7.5 kV. A voltage ramp control components can be connected
Product Description start or current limit start is available. to one Cutler-Hammer IT. D77D gate-
The Cutler-Hammer® Intelligent Tech- Kick-start is available in either starting way. The gateway concentrates data
nologies (IT.) MV811 Line of Reduced mode. The soft stop option allows for from the devices into a single node.
Voltage Soft Starters from Eaton’s a ramp stop time that is longer than Configuration is simple — a single
electrical business is very compact, the coast to stop time. The pump press of the gateway’s Auto Configura-
multi-functional, easy to install and control option provides a smooth tion button sets the system up for
easy to program. Designed to control transition for starting and stopping a default operation. This automatically
the acceleration and deceleration of motor and eliminating the “water- configures the I/O assemblies to the
three-phase medium voltage motors hammer” effect that can damage QCPort system devices. The data from
up to 7.5 kV. The line is available from pipes, valves and pumps. these devices are then assembled into
11 amp through 420 amp applications single input and output messages.
The MV811 offers an impressive array of
as an open unit or in the Ampgard ® IT. advanced protective features. Not only The MV811 communication parame-
starter assembly. This product is are the protective features selectable, ters can be configured with the DIM or
perfect for the EOEM who wants to but many offer variable settings allow- through the fieldbus using CH Studio
add value by installing the MV811 in ing the user to fine tune the starter to Component Manager. Advanced
their own structure design. The MV811 meet specific system requirements. communication configuration settings
can easily fit in the space where an provide the system integrator with
existing Reduced Voltage Auto The MV811 has an easy-to-use Digital
powerful tools to facilitate system
Transformer was. Interface Module (DIM) that allows the
optimization.
user to configure the device and to
The IT. MV811 Line of Reduced Voltage read system parameters. The DIM
Soft Starters comes standard with the includes an LCD display and keypad to
following: scroll through the various menus. The
■ Control Module DIM allows the user to modify control
parameters, enable or disable protec-
■ Digital Interface Module
tions, set communication variables,
monitor system parameters such as
line voltages and currents, and access
the fault queue.

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 3
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

■ Provides accurate current measure-


ment and trip settings. Sophisti-
24V DC
Power cated algorithms solve a series of
FieldBus Supply differential equations that model
true motor heating and cooling
resulting in superior motor overload
protection while minimizing nui-
sance trips. Advanced selectable
protective features safeguard the
motor and system against a variety
of system faults.
■ Eliminate the need for additional
Network Terminator
devices, thereby reducing enclo-
Adapter & sure sizes, minimizing installation
(Gateway) Power Tap and wiring time, and reducing
DIM enclosure sizes, minimizing installa-
tion and wiring time, and reducing
overall assembly size and cost.
■ Provide unlimited starting configu-
rations allowing for maximum
application flexibility.
IT. MV811 Soft Starter ■ Enables soft starting of high
DIN Rail friction loads.
+– 1 0 Communications
Backplane ■ Allows for wide application range
while offering users the flexibility to
fine tune the starter to match their
specific application requirements.
Figure 2. MV811 Connection Diagram
■ Sophisticated pump algorithm on
Table 1. Communications Reference both starting and stopping minimize
the pressure surges that cause
Description Part Catalog
Number Page 
water hammer. The pump control
option will maximize the life of the
DeviceNet Network Adapter D77D-DNA 50-40 pump and piping systems while
EtherNet Modbus Network Adapter D77D-EMA 50-42 minimizing the downtime caused
EtherNet/IP Network Adapter D77D-EIP 50-44 by system failure.
PROFIBUS Network Adapter D77D-PNA 50-46 ■ Control all three phases
Terminator and Power Tap D77E-QPLR 50-35
providing smooth acceleration
and deceleration.
DIN Rail Communications Backplane, 7-position D77E-BP7 50-35
■ Reduces wear on belts, gears,
DIN Rail Communications Backplane, 12-position D77E-BP12 50-35
chains, clutches, shafts and
2.5 kV Power Supply (110 — 240V AC Input) PSS300E  44-65 bearings.
2.5 kV Power Supply (380 — 480V AC Input) PSS600C  44-65 ■ Enhances personnel and equipment
5 kV Power Supply (380 — 480V AC Input) PSS600C  44-65 safety.
7.2 kV Power Supply (380 — 480V AC Input) PSS600C  44-65 ■ Reduce the peak inrush current's
 Catalog page numbers refer to the Control products catalog, CA08102001E. stress on the power system.
 A minimum wire size of 14 AWG (2.5 mm2) should be used between the power supply and the ■ Provides control for applications
24V DC +/- terminals.
where an abrupt stop of the load is
not acceptable.
Features and Benefits ■ System operating parameters
■ Minimize peak starting torque to
can be monitored enterprise-wide
diminish mechanical system wear
■ DIM provides an intuitive, easy-to- through a communications network.
and damage.
use human interface with powerful Increase uptime by providing data
configuration capabilities to maxi- for process management and ■ Removable, lockable control termi-
mize system performance. preventive diagnostics. nal block reduces maintenance
costs. Also provides the opportunity
■ Door or device mounted DIM ■ Significantly reduces the heat
for OEMs to reduce assembly and
enables users to safely configure, generated by the starter, minimizing
test costs by utilizing pre-assembled
commission, monitor and trouble- enclosure sizes and costs. Run
wire harnesses.
shoot the system at the electrical bypass mode greatly reduces inter-
panel without opening the enclo- nal heating created by the SCRs,
sure door, eliminating the possibility while the bypass contractor directly
of an arc flash incident. connects the motor to the line and
improves system efficiency by
reducing internal power losses.

CA03902002E For more information visit: www.eaton.com


4 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

■ Provides OEM customers with The trip current is adjusted to match Pole Over Temperature
design flexibility. This feature the specific application requirements High ambient temperatures, extended
results in the control circuitry by entering the motor nameplate full ramp times and high duty cycle condi-
operating at lower temperatures, load current rating and trip class. The tions may cause the MV811 power
maximizing the life of the electron- FLA adjustment includes a 3 to 1 pole conductors to reach a tempera-
ics components. Electromagnetic adjustment range. The overload trip ture that exceeds their thermal rating.
interference from the power circuit class is adjustable from class 5 The MV811 is equipped with sensors
is also minimized. through class 30. The overload is that monitor the temperature of the
■ Encases the SCRs, power circuitry, ambient temperature compensated — power poles. Over temperature protec-
run bypass contactors and overload meaning its trip characteristics will not tion occurs if the device’s thermal
protection. This uncluttered design vary with changes in ambient temper- capacity is exceeded. The soft starter
simplifies installation and is the ature. The overload protection can be will trip in over temperature condi-
perfect product solution for enabled, disabled, or disabled on start. tions, preventing device failure.
electrical original equipment
Short Circuit The device pole temperature value
manufacturers (EOEMs).
The use of a short circuit protective can be monitored through the DIM or
Protective Features device in coordination with the MV811 the communications network. This
is required in branch motor circuits by feature can be of use in determining
All protective features can be most electrical codes. Short circuit an impending over temperature trip
configured, enabled or disabled coordination ratings with both fuses condition. Alarms can be implemented
with the DIM or through the and Cutler-Hammer molded case cir- in the process monitoring system
communications network. cuit breakers are available providing warning of an impending trip before a
Motor Overload customers with design flexibility. The trip occurs, halting the process. Costly
MV811 has short circuit coordination system shutdown can be avoided.
The MV811 includes electronic over- ratings as an open component, an
load protection as standard. The over- enclosed starter, and in a motor Phase Loss
load meets applicable requirements control center. Loss of a phase can cause a significant
for a motor overload protective device. increase in the current drawn in the
The overload protects the motor from Jam remaining two phases. Phase loss can
over heat conditions with the use of Excessive current and torque up to lead to motor damage before an even-
sophisticated algorithms that model locked rotor levels can occur in a jam tual overload trip occurs. Phase loss is
true motor heating, resulting in condition. The condition can result in typically an indication of a failure in
superior motor protection and fewer stress and damage to the motor, load, the electrical distribution system. The
nuisance trips. mechanical system, and the electrical MV811 will detect a phase loss and trip
The MV811 calculates a thermal mem- distribution system. Jam protection if any phase current drops below a
ory value. A 100% value represents the prevents the stress and damage from preset value. The phase loss trip level
maximum safe temperature of the a jam during normal run. After the is adjustable from 0% to 100% of the
motor. When the thermal memory motor is started, a current greater than average of the other two phase levels
value reaches 100%, an overload trip 300% FLA setting will cause the starter with an adjustable trip delay of 0.1 to
will occur removing power to the to trip on a jam fault. 60 seconds.
motor. Upon trip, the MV811 stores the Stall Phase Imbalance
calculated motor heating value and
Excessive current and torque up to Phase current or voltage imbalance
will not allow a motor re-start until the
locked rotor levels can occur in a stall can cause a significant increase in the
motor has sufficiently cooled. This
condition. The condition can lead to an current drawn in the remaining two
feature ensures the motor will not be
overload trip and result in stress and phases. Phase imbalance can lead to
damaged by repeated overload trip,
damage to the motor, load, mechani- motor damage before an eventual
reset and re-start cycles.
cal system, and the electrical distribu- overload trip. Phase imbalance is
The thermal memory value can be tion system. Stall protection prevents typically an indication of a failure in
monitored through the DIM or the stress and damage to a motor that has the electrical distribution system or
communications network. The thermal not come up to speed, or stalled after the motor. The MV811 will detect both
memory value can be of great use in the soft start time. The MV811 will trip current and voltage phase imbalances
determining an impending overload to protect the system in the event that and trip if any phase becomes imbal-
trip condition. Alarms can be imple- the motor did not get to the rated anced as compared to the average of
mented in the process monitoring speed in the defined soft start period. the other two phases.
system warning of an impending A current greater than 200% FLA at the
end of the soft start period will cause The phase current imbalance trip level
trip before a trip occurs halting the
the starter to trip on a stall fault. is adjustable from 0% to 100% of the
process. Costly system downtime
average of the current in the other two
can be avoided.
phases with an adjustable trip delay of
0.1 to 60 seconds.
The phase voltage imbalance trip level
is adjustable from 0% to 100% of the
average of the voltage in the other two
phases with an adjustable trip delay of
0.1 to 60 seconds.

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 5
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Reset Mode Low Voltage Average Line Current


The MV811 can be set up for automatic Low voltage conditions can result from Provides the average of the three-
or manual reset on trip. The manual disturbances in the electrical power phase RMS line currents in amps,
reset mode requires the operator to distribution system. Low voltage accurate to within 2%. Current data
physically press the RESET button conditions can cause a malfunction can be used to indicate a need for
located on the soft starter. The over- and damage to electrical equipment. maintenance. Increased currents in a
load can be manually reset through The MV811 has low voltage protection fixed load application can indicate a
the DIM or through the communica- that will trip if the average RMS volt- reduction in system efficiencies and
tions network. The overload can also age falls below a preset value. The performance, signifying system
be electrically reset by energizing low voltage protection can be pro- maintenance is due.
a 24V DC input on the control grammed as a percent of nominal
terminal block. voltage from 1% to 99% with a Average Pole Current
trip delay of 0.1 to 60 seconds. Provides the average of the three-
The automatic reset mode allows the phase RMS pole currents in amps,
soft starter to be automatically reset as High Voltage accurate to within 2%. The pole cur-
soon as the trip condition is no longer High voltage conditions can result rent is the current through the soft
present. With the automatic reset from disturbances in the electrical starter. The line and pole current will
mode, after the fault is no longer power distribution system. High volt- be identical in in-line applications,
present, the motor will be restarted as age conditions can cause malfunctions and will differ in inside-the-delta
soon as a valid start signal is present. or failures of electrical equipment. The applications.
Phase Reversal MV811 has high voltage protection
that will trip if the average RMS volt- Average line current as a % FLA
The MV811 can determine if the age is greater than a preset value. The Provides the average RMS line current
proper line phase sequence is present high voltage protection can be pro- as a percentage of the MV811 FLA
by default. The device will trip if the grammed as a percent of nominal setting.
line phase sequence is something voltage from 101% to 120% with a
other than A-B-C. The S811 can be trip delay of 0.1 to 60 seconds. Three-Phase Line Currents
configured to operate under reversed Provides three RMS phase line
phase conditions (A-C-B). Monitoring Capabilities currents in amps, accurate to within
2%. Imbalances or changes in the
Shorted SCR Detection The MV811 has an impressive array of relative phase current to one another
The MV811 monitors the operation of system monitoring capabilities that can indicate anomalies in the motor
the power poles and will trip under a allow users to access real time process or electrical distribution system.
shorted SCR condition. and diagnostic data. This data can be
viewed at the device with the DIM or Three-Phase Pole Currents
Open SCR Detection through a communications network. Provides three RMS phase pole
The MV811 monitors the operation of Data over a communications network currents in amps, accurate to within
the power poles and will trip under an can provide valuable insight into the 2%. The pole current is the current
open SCR condition. condition of the equipment and pro- through the soft starter. The line and
cesses. Maintenance and production pole current will be identical in in-line
Low Current personnel can monitor critical opera- applications, and will differ in inside-
Low current conditions can be a result tional and maintenance data from a the-delta applications.
of a loss of load or a failure in the central control station that can be
mechanical system. The MV811 has located far away from the production Three-Phase Line Voltages
low current protection that will trip if facility. Process data can be monitored Provides the individual RMS three-
the average RMS current falls below a to determine system anomalies that phase line voltages. Imbalances or
preset value. The low current protec- may indicate a need for preventive changes in the relative phase voltage
tion can be programmed as a percent maintenance or an impeding failure. to one another can indicate anomalies
of motor FLA from 0% to 100%. Adjustments made through the com- in the motor or electrical distribution
munications network can reduce costs system. Voltage can be used to moni-
by minimizing the time traveling to the tor electrical distribution system per-
location where the motor controls are formance. Warnings, alarms and
located. When faults do occur, real system actions to low or high voltage
time fault data can assist maintenance conditions can be implemented.
in troubleshooting and planning repair
resources. Remote reset signals can be
given to tripped devices without the
need for manual intervention by main-
tenance personnel.

CA03902002E For more information visit: www.eaton.com


6 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Percent Thermal Memory Device Temperature Control Status


Provides the real time calculated An increase in device temperature is a The MV811 provides data that repre-
thermal memory value. The MV811 strong indication of an increase in sents system conditions that can be
calculates thermal memory value. A ambient temperature. High ambient read through the DIM or the communi-
100% value represents the maximum temperature operation can be identi- cations network. This data identifies
safe temperature of the motor. When fied with the Device Temperature data. the status of the system and the con-
the thermal memory value reaches Ambient temperature increases can be trol commands the system is request-
100%, an overload trip will occur, due to loss of enclosure cooling fans ing of the MV811. This can be used for
removing power to the motor. or blocked venting. High ambient advanced troubleshooting and
temperatures will reduce the life of all system integration activities.
The thermal memory value can be of electrical equipment in the enclosure.
great use in determining an impending Breaker Status
overload trip condition. Alarms can be Start Count The MV811 has provisions to read and
implemented in the process monitor- Start count data can be used to display circuit breaker status. Cutler-
ing system warning of an impending monitor system output, schedule Hammer communicating Cover
trip before a trip occurs, halting the preventative maintenance, identify Control or other communicating
process. Costly system downtime can system anomalies and identify protective device is required to take
be avoided. changes in system operation. advantage of this feature.
DC Control Voltage
Diagnostics
Monitors level of the 24V DC control
voltage. Fluctuations in control voltage Fault Queue
can cause component malfunction and
Current fault and a fault queue con-
failure. System control voltage data
taining the last nine system faults can
can be used to implement warnings,
be read through the DIM or communi-
alarms and system actions to low or
cations network. Fault identification
high voltage conditions.
can minimize troubleshooting time
Pole Temperature and cost and prevent arc flash inci-
Increases in pole temperature are dents. The fault queue can be remotely
caused by increases in ambient tem- accessed through a communications
perature, start/stop times and start network to assist in planning mainte-
duty cycles. Changes in pole tempera- nance resources. 30 different faults
tures represent a change in system can be identified by the MV811.
operating conditions. Identifying
unexpected operating conditions or
changes can prompt maintenance and
aid in process evaluation activities.

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 7
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Operation

Locked Rotor Torque


Starting and Stopping Modes 100%
The MV811 has a variety of starting
and stopping methods to provide
superior performance in the most Run (FLA)
demanding applications. The motor
Initial
can be started in either Voltage Ramp Torque
Start or Current Limit Start mode. Kick
Start and Soft Stop are available
within both starting modes. Time (Seconds)

Voltage Ramp Start


Figure 3. Starting Characteristics — Ramp Start
Provides a voltage ramp to the motor
resulting in a constant torque increase.
The most commonly used form of soft
start, this start mode allows you to
set the initial torque value and the Max.
duration of the ramp to full voltage Allowed
Current

conditions. Bypass contactors close


after ramp time. Run
100%
■ Adjustable initial torque 0 – 85% FLA
of locked rotor torque.
■ Adjustable ramp time 0.5 – 180
seconds (can be extended with Time (Seconds)
factory modification).
Current Limit Start Figure 4. Starting Characteristics — Current Limit Start
Limits the maximum current available
to the motor during the start phase.
100%
This mode of soft starting is used when
it becomes necessary to limit the maxi-
mum starting current due to long start
Locked Rotor Torque

times or to protect the motor. This start


mode allows you to set the maximum
starting current as a percentage of
locked rotor current and the duration of
the current limit. Bypass contactors
close after current limit time. Run (FLA)
■ Maximum current of 0 – 85% locked
rotor current.
■ Adjustable ramp time 0.5 – 180
seconds (can be extended with Kick
Start Ramp
factory modification).
Time (Seconds)
Kick Start
Selectable feature in both Voltage Figure 5. Starting Characteristics — Kick Start
Ramp Start and Current Limit Start
modes. Provides a current and torque
“kick” for 0 to 2.0 seconds. This pro-
vides greater initial current to develop Run
additional torque to breakaway a high
friction load.
■ 0 – 85% of locked rotor torque
■ 0 – 2.0 seconds duration
Soft Stop
Allows for a controlled stopping of a
load. Used when a stop-time that is Ramp
greater than the coast-to-stop time is Time (Seconds)
desired. Often used with high friction
loads where a sudden stop may cause Figure 6. Starting Characteristics — Soft Stop
system or load damage.
■ Stop time = 0 – 60 seconds.

CA03902002E For more information visit: www.eaton.com


8 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Component Identification
MV811 Soft Starter Assembly

Power Module
Assembly (3-Phase)

Control Module

Control Interface
Module

Power Pole Assembly Wiring Harness


(1-Phase)

Figure 7. Component Identification — MV811 Soft Starter Assembly

Catalog Number Selection


Table 2. MV811 Open Soft Starters Catalog Numbering System

SMV 811 A 42 N 3 S
Line Style
SMV = IT. MV Soft Starter S = Standard Soft Starter
AMV = Ampgard IT. MV Soft Starter L = Extended Ramp Start
C = Forced Air Cooling

Model
Number of Poles
811 = Non-combination Soft Starter
3 = 3-Pole Device

Frame Size
Options
A = 2,500V
B = 5,000V N = No Options
C = 7,500V P = Pump Control

Ampacity Rating
37 = 37 amps 24 = 240 amps
66 = 66 amps 30 = 300 amps
10 = 105 amps 36 = 360 amps
13 = 135 amps 42 = 420 amps
18 = 180 amps

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 9
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Product Selection
Horsepower and kW Ratings
Based on standard duty ratings.
Table 3. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 37 125 — — — — — 125 — — — — — SMV811A37N3S 21,516.00


B 37 125 163 200 219 253 261 125 150 200 200 250 300 SMV811B37N3S 33,594.00
A 66 223 — — — 391 — — 250 — — — — — SMV811A66N3S 21,813.00
B 66 223 291 320 451 521 250 350 400 400 450 500 SMV811B66N3S 34,188.00
A 105 355 — — — — — 400 — — — — — SMV811A10N3S 22,990.00
B 105 355 463 510 621 718 828 400 500 600 600 700 800 SMV811B10N3S 36,542.00
A 135 457 — — — 799 — —1065 500 — — — — — SMV811A13N3S 23,287.00
B 135 457 596 655 923 500 700 800 800 900 1000 SMV811B13N3S 37,136.00
A 180 609 — — — — — 700 — — — — — SMV811A18N3S 27,115.00
B 180 609 794 873 1065 1231 1420 700 1000 1000 1100 1200 1400 SMV811B18N3S 40,656.00
A 240 812 — — — — — 900 — — — — — SMV811A24N3S 27,709.00
B 240 812 1059 1165 1420 1641 1893 900 1300 1400 1500 1600 1800 SMV811B24N3S 41,250.00
A 304 1028 — — — — — 1200 — — — — — SMV811A30N3S 28,281.00
B 304 1028 1341 1475 1799 2087 2398 1200 1600 1800 2000 2000 2300 SMV811B30N3S 41,844.00
A 360 1218 — — — — — 1300 — — — — — SMV811A36N3S 28,875.00
B 360 1218 1588 1747 2130 2461 2840 1300 2000 2100 2300 2400 2800 SMV811B36N3S 42,427.00
A 420 1421 — — — — — 1600 — — — — — SMV811A42N3S 29,469.00
B 420 1421 1853 2038 2485 2872 3313 1600 2300 2500 2700 2800 3300 SMV811B42N3S 43,021.00

Table 4. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

37 299 326 343 359 375 392 300 350 350 400 400 400 SMV811C37N3S 48,711.30
66 534 582 611 641 670 699 500 600 600 700 700 700 SMV811C66N3S 49,572.60
105 849 926 973 1019 1065 1112 900 1000 1000 1100 1100 1250 SMV811C10N3S 52,985.90
135 1092 1191 1251 1310 1370 1429 1200 1300 1300 1400 1500 1600 SMV811C13N3S 53,847.20
180 1456 1588 1668 1747 1862 1906 1600 1700 1800 1900 2000 2100 SMV811C18N3S 58,951.20
240 1941 2118 2223 2329 2435 2541 2100 2300 2400 2500 2700 2800 SMV811C24N3S 59,812.50
304 2459 2682 2816 2950 3085 3219 2700 2900 3100 3200 3400 3600 SMV811C30N3S 60,673.80
360 2912 3176 3335 3494 3653 3812 3200 3500 3700 3800 4000 4200 SMV811C36N3S 61,519.15
420 3397 3706 3891 4076 4262 4447 3700 4100 4300 4500 4700 5000 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


10 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 5. 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 34 115 — — — — — 125 — — — — — SMV811A37N3S 21,516.00


B 34 115 150 165 180 208 240 125 150 150 200 200 250 SMV811B37N3S 33,594.00
A 63 213 — — — — — 200 — — — — — SMV811A66N3S 21,813.00
B 63 213 278 306 334 385 445 200 300 300 350 400 500 SMV811B66N3S 34,188.00
A 96 325 — — — — — 350 — — — — — SMV811A10N3S 22,990.00
B 96 325 424 466 508 587 678 350 450 500 500 600 700 SMV811B10N3S 36,542.00
A 120 406 — — — — — 450 — — — — — SMV811A13N3S 23,287.00
B 120 406 534 582 635 734 847 450 600 600 700 800 900 SMV811B13N3S 37,136.00
A 150 507 — — — — — 500 — — — — — SMV811A18N3S 27,115.00
B 150 507 662 728 794 918 1059 500 700 800 800 1000 1100 SMV811B18N3S 40,656.00
A 215 727 — — — — — 800 — — — — — SMV811A24N3S 27,709.00
B 215 727 948 1043 1138 1315 1518 800 1000 1100 1250 1400 1600 SMV811B24N3S 41,250.00
A 278 940 — — — — — 1000 — — — — — SMV811A30N3S 28,281.00
B 278 940 1226 1349 1472 1701 1962 1000 1300 1500 1600 1900 2100 SMV811B30N3S 41,844.00
A 320 1082 — — — — — 1200 — — — — — SMV811A36N3S 28,875.00
B 320 1082 1412 1553 1694 1958 2259 1200 1700 1700 1800 2200 2500 SMV811B36N3S 42,427.00
A 380 1285 — — — — — 1400 — — — — — SMV811A42N3S 29,469.00
B 380 1285 1676 1844 2012 2325 2682 1400 2000 2000 2200 2600 2900 SMV811B42N3S 43,021.00

Table 6. 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

34 275 300 315 330 345 360 300 300 350 350 350 400 SMV811C37N3S 48,711.30
63 510 556 584 611 639 667 500 600 600 600 700 700 SMV811C66N3S 49,572.60
96 776 847 889 932 974 1016 800 900 900 1000 1000 1100 SMV811C10N3S 52,985.90
120 971 1059 1112 1165 1218 1271 1000 1100 1200 1300 1300 1400 SMV811C13N3S 53,847.20
150 1213 1323 1390 1456 1522 1588 1300 1400 1500 1600 1600 1700 SMV811C18N3S 58,951.20
215 1739 1897 1992 2087 2181 2276 1900 2100 2200 2300 2400 2500 SMV811C24N3S 59,812.50
278 2248 2453 2575 2698 2821 2943 2500 2700 2800 3000 3100 3300 SMV811C30N3S 60,673.80
320 2588 2823 2965 3106 3247 3388 2800 3100 3300 3400 3600 3800 SMV811C36N3S 61,519.15
380 3073 3353 3520 3688 2856 4023 3400 3700 3900 4100 4200 4500 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 11
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 7. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 34 115 — — — — — 125 — — — — — SMV811A37N3S 21,516.00


B 34 115 150 165 180 180 240 125 150 150 200 200 250 SMV811B37N3S 33,594.00
A 63 213 — — — — — 200 — — — — — SMV811A66N3S 21,813.00
B 63 213 278 306 334 334 445 200 300 300 350 350 500 SMV811B66N3S 34,188.00
A 96 325 — — — — — 350 — — — — — SMV811A10N3S 22,990.00
B 96 325 424 466 508 508 678 350 450 500 500 500 700 SMV811B10N3S 36,542.00
A 120 406 — — — — — 450 — — — — — SMV811A13N3S 23,287.00
B 120 406 529 582 635 635 847 450 600 600 700 700 900 SMV811B13N3S 37,136.00
A 150 507 — — — — — 500 — — — — — SMV811A18N3S 27,115.00
B 150 507 662 728 794 794 1059 500 700 800 800 800 1100 SMV811B18N3S 40,656.00
A 215 727 — — — — — 800 — — — — — SMV811A24N3S 27,709.00
B 215 727 948 1043 1138 1138 1518 800 1000 1100 1250 1250 1600 SMV811B24N3S 41,250.00
A 278 940 — — — — — 1000 — — — — — SMV811A30N3S 28,281.00
B 278 940 1226 1349 1472 1472 1962 1000 1300 1500 1600 1600 2100 SMV811B30N3S 41,844.00
A 320 1082 — — — — — 1200 — — — — — SMV811A36N3S 28,875.00
B 320 1082 1412 1553 1694 1694 2259 1200 1500 1700 1800 1800 2500 SMV811B36N3S 42,427.00
A 380 1285 — — — — — 1400 — — — — — SMV811A42N3S 29,469.00
B 380 1285 1676 1844 2012 2012 2682 1400 1800 2000 2200 2200 2900 SMV811B42N3S 43,021.00

Table 8. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

34 257 300 315 330 345 360 300 300 350 350 350 400 SMV811C37N3S 48,711.30
63 510 556 584 611 639 667 500 600 600 600 700 700 SMV811C66N3S 49,572.60
96 776 847 889 932 974 1016 800 900 900 1000 1000 1100 SMV811C10N3S 52,985.90
120 971 1059 1112 1165 1218 1271 1000 1100 1200 1300 1300 1400 SMV811C13N3S 53,847.20
150 1213 1323 1390 1456 1522 1588 1300 1400 1500 1600 1600 1700 SMV811C18N3S 58,951.20
215 1739 1897 1992 2087 2181 2276 1900 2100 2200 2300 2400 2500 SMV811C24N3S 59,812.50
278 2248 2453 2575 2698 2821 2943 2500 2700 2800 3000 3100 3300 SMV811C30N3S 60,673.80
320 2588 2823 2965 3106 3247 3388 2800 3100 3300 3400 3600 3800 SMV811C36N3S 61,519.15
380 3073 3353 3520 3688 3856 4023 3400 3700 3900 4100 4200 4500 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


12 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 9. 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 21 — — — — — — — — — — — — SMV811A37N3S 21,516.00
B 21 — — — 111 128 148 — — — 125 125 150 SMV811B37N3S 33,594.00
A 42 142 — — — — — 150 — — — — — SMV811A66N3S 21,813.00
B 42 142 185 204 222 257 296 150 200 200 250 250 300 SMV811B66N3S 34,188.00
A 60 203 — — — — — 250 — — — — — SMV811A10N3S 22,990.00
B 60 203 265 291 318 367 424 250 300 300 350 400 450 SMV811B10N3S 36,542.00
A 80 271 — — — — — 300 — — — — — SMV811A13N3S 23,287.00
B 80 271 353 388 424 489 565 300 400 400 450 500 600 SMV811B13N3S 37,136.00
A 115 389 — — — — — 400 — — — — — SMV811A18N3S 27,115.00
B 115 389 507 558 609 703 812 400 500 600 600 800 900 SMV811B18N3S 40,656.00
A 150 507 — — — — — 500 — — — — — SMV811A24N3S 27,709.00
B 150 507 662 728 794 918 1059 500 700 800 800 1000 1100 SMV811B24N3S 41,250.00
A 192 649 — — — — — 700 — — — — — SMV811A30N3S 28,281.00
B 192 649 847 935 1016 1175 1355 700 900 1000 1100 1300 1500 SMV811B30N3S 41,844.00
A 280 947 — — — — — 1000 — — — — — SMV811A36N3S 28,875.00
B 280 947 1235 1359 1482 1713 1976 1000 1300 1500 1600 1900 2200 SMV811B36N3S 42,427.00
A 340 1150 — — — — — 1300 — — — — — SMV811A42N3S 29,469.00
B 340 1150 1500 1650 1800 2080 2400 1300 1600 1800 2000 2300 2600 SMV811B42N3S 43,021.00

Table 10. 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

21 170 185 195 204 213 222 150 200 200 200 200 250 SMV811C37N3S 48,711.30
42 340 371 389 408 426 445 350 400 400 450 450 500 SMV811C66N3S 49,572.60
60 485 529 556 582 609 635 500 500 600 600 600 700 SMV811C10N3S 52,985.90
80 647 706 741 776 812 847 700 700 800 800 900 900 SMV811C13N3S 53,847.20
115 930 1015 1065 1116 1167 1218 1000 1100 1100 1200 1300 1300 SMV811C18N3S 58,951.20
150 1213 1323 1390 1456 1522 1588 1300 1400 1500 1600 1600 1700 SMV811C24N3S 59,812.50
192 1553 1694 1779 1863 1948 2033 1700 1800 1900 2000 2100 2200 SMV811C30N3S 60,673.80
280 2265 2470 2594 2717 2841 2965 2500 2700 2800 3000 3100 3300 SMV811C36N3S 61,519.15
340 2750 3000 3150 3300 3450 3600 3000 3300 3500 3600 3800 4000 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 13
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 11. 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 29 — — — — — — — — — — — — SMV811A37N3S 21,516.00
B 29 — 128 141 154 177 205 — 150 150 150 200 200 SMV811B37N3S 33,594.00
A 49 166 — — — — — 150 — — — — — SMV811A66N3S 21,813.00
B 49 166 216 238 259 300 346 150 250 250 250 300 350 SMV811B66N3S 34,188.00
A 73 247 — — — — — 250 — — — — — SMV811A10N3S 22,990.00
B 73 247 322 359 386 447 515 250 350 400 400 500 500 SMV811B10N3S 36,542.00
A 94 318 — — — — — 350 — — — — — SMV811A13N3S 23,287.00
B 94 318 415 456 498 575 663 350 450 500 500 600 700 SMV811B13N3S 37,136.00
A 155 524 — — — — — 500 — — — — — SMV811A18N3S 27,115.00
B 155 524 684 752 821 948 1094 500 700 800 900 1000 1200 SMV811B18N3S 40,656.00
A 219 741 — — — — — 800 — — — — — SMV811A24N3S 27,709.00
B 219 741 966 1063 1159 1340 1546 800 1000 1100 1250 1500 1700 SMV811B24N3S 41,250.00
A 280 947 — — — — — 1000 — — — — — SMV811A30N3S 28,281.00
B 280 947 1235 1359 1482 1713 1976 1000 1300 1500 1600 1900 2200 SMV811B30N3S 41,844.00
A 345 1167 — — — — — 1300 — — — — — SMV811A36N3S 28,875.00
B 345 1167 1522 1674 1826 2110 2435 1300 1700 1800 2000 2300 2700 SMV811B36N3S 42,427.00
A 405 1370 — — — — — 1500 — — — — — SMV811A42N3S 29,469.00
B 405 1370 1787 1965 2144 2477 2859 1500 2000 2100 2300 2800 3100 SMV811B42N3S 43,021.00

Table 12. 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

29 235 256 269 281 294 307 250 250 300 300 300 350 SMV811C37N3S 48,711.30
49 396 432 454 476 497 519 400 450 500 500 500 500 SMV811C66N3S 49,572.60
73 590 644 676 708 741 773 600 700 700 700 800 800 SMV811C10N3S 52,985.90
94 760 829 871 912 954 995 800 900 900 1000 1000 1100 SMV811C13N3S 53,847.20
155 1254 1368 1436 1504 1573 1641 1300 1500 1600 1600 1600 1800 SMV811C18N3S 58,951.20
219 1771 1932 2029 2125 2222 [?] 1900 2100 2200 2300 2400 2600 SMV811C24N3S 59,812.50
280 2265 2470 2594 2717 2841 3300 2500 2700 2800 3000 3100 3300 SMV811C30N3S 60,673.80
345 2790 3044 3196 3348 3501 4100 3100 3300 3500 3700 3800 4100 SMV811C36N3S 61,519.15
405 3276 3573 4100 3931 4109 4800 3600 3900 4100 4300 4500 4800 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


14 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 13. 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 21 — — — — — — — — — — — — SMV811A37N3S 21,516.00
B 21 — — — 111 128 148 — — — 125 125 150 SMV811B37N3S 33,594.00
A 40 135 — — — — — 150 — — — — — SMV811A66N3S 21,813.00
B 40 135 176 194 212 245 282 150 200 200 200 250 300 SMV811B66N3S 34,188.00
A 55 186 — — — — — 200 — — — — — SMV811A10N3S 22,990.00
B 55 186 243 267 291 336 388 200 250 300 300 350 400 SMV811B10N3S 36,542.00
A 75 254 — — — — — 250 — — — — — SMV811A13N3S 23,287.00
B 75 254 331 364 397 459 529 250 350 400 450 500 600 SMV811B13N3S 37,136.00
A 151 511 — — — — — 500 — — — — — SMV811A18N3S 27,115.00
B 151 511 666 733 799 924 1066 500 700 800 800 1000 1100 SMV811B18N3S 40,656.00
A 215 727 — — — — — 800 — — — — — SMV811A24N3S 27,709.00
B 215 727 948 1043 1138 1315 1518 800 1000 1100 1250 1400 1600 SMV811B24N3S 41,250.00
A 264 893 — — — — — 1000 — — — — — SMV811A30N3S 28,281.00
B 264 893 1165 1281 1398 1615 1863 1000 1300 1400 1500 1800 2000 SMV811B30N3S 41,844.00
A 300 1015 — — — — — 1100 — — — — — SMV811A36N3S 28,875.00
B 300 1015 1323 1456 1588 1835 2118 1100 1400 1600 1700 2000 2300 SMV811B36N3S 42,427.00
A 340 1150 — — — — — 1300 — — — — — SMV811A42N3S 29,469.00
B 340 1150 1500 1650 1800 2080 2400 1300 1600 1800 2000 2300 2600 SMV811B42N3S 43,021.00

Table 14. 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

21 170 185 195 204 213 213 150 200 200 200 200 200 SMV811C37N3S 48,711.30
40 324 353 371 388 406 406 350 350 400 400 450 450 SMV811C66N3S 49,572.60
55 445 485 510 534 558 558 450 500 500 500 600 600 SMV811C10N3S 52,985.90
75 607 662 695 728 761 761 600 700 700 800 800 800 SMV811C13N3S 53,847.20
151 1221 1332 1399 1466 1532 1532 1300 1400 1500 1600 1700 1700 SMV811C18N3S 58,951.20
215 1739 1897 1992 2087 2181 2181 1900 2100 2200 2300 2400 2400 SMV811C24N3S 59,812.50
264 2135 2329 2446 2563 2679 2679 2300 2500 2700 2800 2900 2900 SMV811C30N3S 60,673.80
300 2426 2647 2779 2912 3044 3044 2700 2900 3000 3200 3300 3300 SMV811C36N3S 61,519.15
340 2750 3000 3150 3300 3450 3450 3000 3300 3500 3600 3800 3800 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 15
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 15. >30 Second Ramp, >4 Starts per Hour or >300% Current Limit — Frames A and B
Frame Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

2300 3000 3300 3600 4160 4800 2300V 3000V 3300V 3600V 4160V 4800V
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

A 22 — — — — — — — — — — — — SMV811A37N3S 21,516.00
B 22 — — 107 116 135 155 — — 125 125 150 150 SMV811B37N3S 33,594.00
A 42 142 — — — — — 150 — — — — — SMV811A66N3S 21,813.00
B 42 142 185 204 222 257 296 150 200 200 200 250 300 SMV811B66N3S 34,188.00
A 65 220 — — — — — 250 — — — — — SMV811A10N3S 22,990.00
B 65 220 278 315 344 398 495 250 300 350 350 400 500 SMV811B10N3S 36,542.00
A 80 271 — — — — — 300 — — — — — SMV811A13N3S 23,287.00
B 80 271 353 388 424 489 565 300 400 400 450 500 600 SMV811B13N3S 37,136.00
A 115 389 — — — — — 400 — — — — — SMV811A18N3S 27,115.00
B 115 389 507 558 609 703 812 400 500 600 600 800 900 SMV811B18N3S 40,656.00
A 150 507 — — — — — 500 — — — — — SMV811A24N3S 27,709.00
B 150 507 662 728 794 918 1059 500 700 800 800 1000 1100 SMV811B24N3S 41,250.00
A 192 649 — — — — — 700 — — — — — SMV811A30N3S 28,281.00
B 192 649 847 932 1016 1175 1355 700 900 1000 1100 1300 1500 SMV811B30N3S 41,844.00
A 240 812 — — — — — 900 — — — — — SMV811A36N3S 28,875.00
B 240 812 1059 1165 1271 1468 1694 900 1200 1300 1400 1600 1800 SMV811B36N3S 42,427.00
A 305 1032 — — — — — 1100 — — — — — SMV811A42N3S 29,469.00
B 305 1032 1346 1480 1615 1866 2153 1100 1500 1600 1800 2100 2400 SMV811B42N3S 43,021.00

Table 16. >30 Second Ramp, >4 Starts per Hour or >300% Current Limit — Frame C
Max Three-Phase Motor Catalog Price
Current kW Rating (50 – 60 Hertz) hp Rating (50 – 60 Hertz) Number U.S. $

5500 6000 6300 6600 6900 7200 5500 6000 6300 6600 6900 7200
Volt Volt Volt Volt Volt Volt 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF 1.15SF

22 178 194 204 214 223 233 200 200 200 200 250 250 SMV811C37N3S 48,711.30
42 340 371 389 408 426 445 350 400 400 450 450 500 SMV811C66N3S 49,572.60
65 526 573 602 631 660 688 500 600 600 700 700 700 SMV811C10N3S 52,985.90
80 647 705 741 776 812 847 600 700 800 800 900 900 SMV811C13N3S 53,847.20
115 930 1015 1065 1116 1167 1218 1000 1100 1100 1200 1300 1300 SMV811C18N3S 58,951.20
150 1213 1323 1390 1456 1522 1588 1300 1400 1500 1600 1600 1700 SMV811C24N3S 59,812.50
192 1553 1694 1779 1863 1948 2033 1700 1800 1900 2000 2100 2200 SMV811C30N3S 60,673.80
240 1941 2118 2223 2329 2435 2541 2100 2300 2400 2500 2700 2800 SMV811C36N3S 61,519.15
305 2467 2691 2826 3200 3096 3229 2700 2900 3100 3200 3400 3600 SMV811C42N3S 62,380.45

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


16 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Options Pump Control


For a pump control option, change the 10th digit in the
Extended Ramp Catalog Number from Page 8 to P (i.e. SMV811A42P3S).
For a longer ramp acceleration time of 1.0 – 360 seconds, Table 18. Pump Control
change the 12th digit in the Catalog Number from
Max. Max. Current Catalog Price
Page 8 to L (i.e. SMV811A42N3L). Voltage Rating Number U.S. $
Table 17. Extended Ramp A-Frame
Max. Max. Current Catalog Price 2,500 37 SMV811A37P3S 23,667.60
Voltage Rating Number U.S. $ 66 SMV811A66P3S 23,994.30
105 SMV811A10P3S 25,289.00
A-Frame 135 SMV811A13P3S 25,615.70
2,500 37 SMV811A37N3L 22,591.80 180 SMV811A18P3S 29,826.50
66 SMV811A66N3L 22,903.65 240 SMV811A24P3S 30,479.90
105 SMV811A10N3L 24,139.50
304 SMV811A30P3S 31,109.10
135 SMV811A13N3L 24,451.35
360 SMV811A36P3S 31,762.50
180 SMV811A18N3L 28,470.75
420 SMV811A42P3S 32,415.90
240 SMV811A24N3L 29,094.45
B-Frame
304 SMV811A30N3L 29,695.05
360 SMV811A36N3L 30,318.75 5,000 37 SMV811B37P3S 36,953.40
420 SMV811A42N3L 30,942.45 66 SMV811B66P3S 37,606.80
105 SMV811B10P3S 40,196.20
B-Frame 135 SMV811B13P3S 40,849.60
5,000 37 SMV811B37N3L 35,273.70 180 SMV811B18P3S 44,721.60
66 SMV811B66N3L 35,897.40
240 SMV811B24P3S 45,375.00
105 SMV811B10N3L 38,369.10
304 SMV811B30P3S 46,028.40
135 SMV811B13N3L 38,992.80
360 SMV811B36P3S 46,669.70
180 SMV811B18N3L 42,688.80
420 SMV811B42P3S 47,323.10
240 SMV811B24N3L 43,312.50
C-Frame
304 SMV811B30N3L 43,936.20
360 SMV811B36N3L 44,548.35 7,500 37 SMV811C37P3S 53,582.43
420 SMV811B42N3L 45,172.05 66 SMV811C66P3S 54,529.86
105 SMV811C10P3S 58,284.49
C-Frame 135 SMV811C13P3S 59,231.92
7,500 37 SMV811C37N3L 51,146.87 180 SMV811C18P3S 64,846.32
66 SMV811C66N3L 52,051.23
240 SMV811C24P3S 65,793.75
105 SMV811C10N3L 55,635.20
304 SMV811C30P3S 66,741.18
135 SMV811C13N3L 56,539.56
360 SMV811C36P3S 67,671.07
180 SMV811C18N3L 61,898.76
420 SMV811C42P3S 68,618.50
240 SMV811C24N3L 62,803.13
304 SMV811C30N3L 63,707.49
360 SMV811C36N3L 64,595.11
420 SMV811C42N3L 65,499.47

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 17
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Power Pole Forced Air Cooling Accessories


Power pole forced air cooling option includes internal fans
to cool power poles. For use in high ambient temperature, User Manual
high duty cycle, and/or long ramp applications. For power Comprehensive instruction manual. This publication can be
pole forced air cooling, change the 12th digit in the Catalog downloaded for free from www.eaton.com by performing a
Number from Page 8 to a C (i.e. SMV811A42N3C). “Document Search” for MN03902010E.
Table 19. Forced Air Cooling
Max. Max. Current Catalog Price
Roll Out Truck
Voltage Rating Number U.S. $ Provide horizontal mounting for up to
A-Frame 2 power pole assemblies (4,160V). Line
2,500 37 SMV811A37N3C 23,022.12
and load stabs provide easy power
66 SMV811A66N3C 23,339.91 wiring connections to Ampgard bus.
105 SMV811A10N3C 24,599.30 Consult factory for more information.
135 SMV811A13N3C 24,917.09
180 SMV811A18N3C 29,013.05
240 SMV811A24N3C 29,648.63 Roll Out Truck
304 SMV811A30N3C 30,260.67
360 SMV811A36N3C 30,896.25 Power Pole Cooling Kit
420 SMV811A42N3C 31,531.83
Optional lug covers with two internal fans per pole allow
B-Frame force air cooling of power poles. For use in high ambient
5,000 37 SMV811B37N3C 35,945.58 temperature, high duty cycle and/or long ramp applications.
66 SMV811B66N3C 36,581.16
105 SMV811B10N3C 39,099.94 Table 20. Power Pole Cooling Kit
135 SMV811B13N3C 39,735.52
Description Catalog Price
180 SMV811B18N3C 43,501.92
Number U.S. $
240 SMV811B24N3C 44,137.50
304 SMV811B30N3C 44,773.08 Cooling Kit MW02A 830.00
360 SMV811B36N3C 45,396.89
420 SMV811B42N3C 46,032.47
C-Frame
7,500 37 SMV811C37N3C 52,121.09
66 SMV811C66N3C 53,042.68
105 SMV811C10N3C 56,694.91
135 SMV811C13N3C 57,616.50
180 SMV811C18N3C 63,077.78
240 SMV811C24N3C 63,999.38
304 SMV811C30N3C 64,920.97
360 SMV811C36N3C 65,825.49
420 SMV811C42N3C 66,747.08

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


18 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Terminal Pad Kits Remote DIM (Digital Interface Module) Mounting Kit
The soft starter power modules are supplied without terminal Used to door mount the control interface module. Does not
pads. Terminal pads are fastened to the soft starter power include the DIM.
bus and provide a threaded hole for customer connection.
Kits are available to accept either a bus bar or a ring terminal Table 22. Remote DIM Mounting Kit
connection. Each kit includes instructions, three terminal Description Catalog Price
pads, hardware to fasten to either the line or line side power Number U.S. $
bus, and hardware for customer connections. Remote mounting kit with 3 ft. cable EMA69A 196.00
Remote mounting kit with 5 ft. cable EMA69B 221.00
Remote mounting kit with 8 ft. cable EMA69C 245.00
Remote mounting kit with 10 ft. cable EMA69D 271.00

Table 23. MV811 Accessory Kits


Common Notes Catalog Price
Name Number U.S. $

Arrestor Kit 2.5 kV (contains 3 Arrestors with MW03A 672.65


Mounting bracket and hardware)
5 kV (contains 3 Arrestors with MW03B 707.29
Terminal Pad Kit Mounting bracket and hardware)
7.2 kV (contains 3 Arrestors with MW03C 1357.23
Mounting bracket and hardware)
Power 2.5 kV (110 — 240V AC Input) PSS300E  631.00
Supply 2.5 kV (380 — 480V AC Input) PSS600C  1054.00
5 kV (380 — 480V AC Input) PSS600C  1054.00
7.2 kV (380 — 480V AC Input) PSS600C  1054.00
Lifting Kit Used to lift device out of MW04A 26.00
packaging box.
MW01A MW01B MW01C MW01D
 A minimum wire size of 14 AWG (2.5 mm2) should be used between
Terminal Pad Terminal Pad Terminal Pad Terminal Pad
the power supply and the 24V DC +/- terminals.
Table 21. Terminal Pad Kits
Description Conductor Catalog Price
Type Number U.S. $

Terminal pad kit to accept 3/8-16 bolt, Ring lug MW01A 665.00
1.12 inch max ring tang (28.5 mm)
Terminal pad kit to accept 3/8-16 bolt, 2.0 Bus bar MW01B 665.00
inch max width bus bar (50.8 mm) horizontal
Terminal pad kit to accept 3/8-16 bolt, 1.5 Bus bar MW01C 665.00
inch max width bus bar (38.1 mm) vertical
Terminal pad kit to accept 1/2-13 bolt, 2.0 Bus bar MW01D 665.00
inch max width bus bar (50.8 mm) horizontal

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 19
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Renewal Parts Standards and Certifications


Table 24. MV811 Repair Parts ■ UL 347
Common Name Catalog Number Price U.S. $ ■ UL 508
Driver PCB SMV811-MY05B 785.00 ■ CSA C22.2 no. 14-95 in conjunction with T.I.L no. D-21
Harness board ASSY SMV811-MZ01A 4500.00 issued 2-8-95
Power pole assembly — 2500V; 37 Amp SMV811-MY37A 10,450.00 ■ IEC 68-2-30 (dampheat)
Power pole assembly — 2500V; 66 Amp SMV811-MY66A 10,650.00 ■ Solid-State Starters
Power pole assembly — 2500V; 105 Amp SMV811-MY10A 10,850.00
Power pole assembly — 2500V; 135 Amp SMV811-MY13A 11,050.00 Instructional Leaflets
Power pole assembly — 2500V; 180 Amp SMV811-MY18A 11,250.00
Power pole assembly — 2500V; 240 Amp SMV811-MY24A 11,650.00 MN03902010E User Manual
Power pole assembly — 2500V; 304 Amp SMV811-MY30A 11,850.00
IL03902202E Installation Leaflet
Power pole assembly — 2500V; 360 Amp SMV811-MY36A 12,000.00
Power pole assembly — 2500V; 420 Amp SMV811-MY42A 13,050.00
Power pole assembly — 5000V; 37 Amp SMV811-MY37B 18,000.00
Power pole assembly — 5000V; 66 Amp SMV811-MY66B 18,300.00
Power pole assembly — 5000V; 105 Amp SMV811-MY10B 18,600.00
Power pole assembly — 5000V; 135 Amp SMV811-MY13B 18,900.00
Power pole assembly — 5000V; 180 Amp SMV811-MY18B 19,200.00
Power pole assembly — 5000V; 240 Amp SMV811-MY24B 20,000.00
Power pole assembly — 5000V; 304 Amp SMV811-MY30B 20,400.00
Power pole assembly — 5000V; 360 Amp SMV811-MY36B 20,800.00
Power pole assembly — 5000V; 420 Amp SMV811-MY42B 22,460.00
Power pole assembly — 7200V; 37 Amp SMV811-MY37C 30,750.00
Power pole assembly — 7200V; 66 Amp SMV811-MY66C 31,250.00
Power pole assembly — 7200V; 105 Amp SMV811-MY10C 31,750.00
Power pole assembly — 7200V; 135 Amp SMV811-MY13C 32,250.00
Power pole assembly — 7200V; 180 Amp SMV811-MY18C 32,750.00
Power pole assembly — 7200V; 240 Amp SMV811-MY24C 34,200.00
Power pole assembly — 7200V; 304 Amp SMV811-MY30C 34,800.00
Power pole assembly — 7200V; 360 Amp SMV811-MY36C 35,400.00
Power pole assembly — 7200V; 420 Amp SMV811-MY42C 38,500.00
DIM (Ctrl. User Interface w/SS Spec.) EMA91 332.00
DIM Cable MX02A 290.00
Strain Relief (power pole) MX03A 12.00
Power pole top cover (MV Cover Assy.) SMV811-MZ14B 150.00
Terminal block (Female – 12 pin connector) EMA75L 16.20
Blower  MY14B 201.00
Harness Kits OEM Controller MV811 SMV811-MY03D 1600.00
Harness Kits AG Controller AMV811A SMV811-MY03A 810.00
Harness Kits AG Controller AMV811B SMV811-MY03B 1650.00
Harness Kits AG Controller AMV811C SMV811-MY03C 2070.00
Lug Cover Kit, Line or Load SMV811-MX01B 80.00
 Blower w/hardware and gaskets.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1

CA03902002E For more information visit: www.eaton.com


20 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Technical Data and Specifications


Table 25. A-Frame — 2,500V AC
Soft Starter SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811
(Partial Catalog Number) A37 A66 A10 A13 A18 A24 A30 A36 A42
Ratings
Max. Current 37 66 105 135 180 240 304 360 420
Max. Voltage 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500
FLA Current Range 11 – 37 20 – 66 32 – 105 42 – 135 56 – 180 75 – 240 95 – 304 112 – 360 131 – 420
Horsepower Rating @ 60 hz  125 250 400 500 700 900 1200 1400 1600
Max. kW Rating @ 50 hz  125 223 355 457 609 812 1028 1218 1421
Dimensions — Power Module
Width in Inches (mm) 17.4 (441.2)
Height in Inches (mm) 24.2 (613.8)
Depth in Inches (mm) 9.8 (249.2)
Weight in Lbs. (kg) 150 (68.3)
Dimensions — Control Module
Width in Inches (mm) 4.41 (112.1)
Height in Inches (mm) 7.83 (199.0)
Depth in Inches (mm) 3.41 (86.8)
Weight in Lbs. (kg) 5.8 (2.6)
General Information
Bypass Mechanical Life 10M
Insulating Voltage Ui 2,500
Ramp Time Range .5 – 180 Seconds (.5 -360 Seconds Extended Ramp)
Resistance to Vibration Operational: 1g in each axis per IEC 68-2-6
Non-operational: 2.5g in each axis per IEC 68-2-6
Resistance to Shock Operational: 2.5g in each axis per IEC 68-2-27
Non-operational: 5.5g in each axis per IEC 68-2-27
Electrical Information
Operating Voltage 2300
Operating Frequency 47 – 63 Hz
Overload Setting 30 – 100%
Trip Class 5, 10, 20 & 30
Control Wiring
Wire Sizes in AWG 22 – 12
Number of Conductors (Stranded) 2 (or one 14 AWG)
Torque Requirements in lb-in 3.5
Solid, Stranded or Flexible Max. 4.0 mm2
(Size in mm2)
Control Power Requirements
Voltage Range (24V ± 1%) 21.6 – 26.4
Steady State Current Amps 2.3
Inrush Current Amps 10.5
Ripple 1%
Relays (1) Class A and C
Voltage AC — maximum 240
Voltage DC — maximum 120
Amps — maximum 3
Environment
Temperature — Operating -30 – 40°C (No Derating) Consult factory for operation > 40°C
Temperature — Storage -50 – 70°C
Altitude 2,000 meters (without derating) Consult factory for operation > 2,000 meters
Humidity < 95% non-condensing
Operating Position Any
Pollution Degree IEC947-1 3
Impulse withstand Voltage 60 kV
IEC947-4-1
 Based on 300% max. current, 15 second ramp, 4 starts per hour and 40°C ambient temperature.

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 21
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 26. B-Frame - 5,000V AC


Soft Starter SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811
(Partial Catalog Number) B37 B66 B10 B13 B18 B24 B30 B36 B42
Ratings
Max. Current 37 66 105 135 180 240 304 360 420
Max. Voltage 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000
FLA Current Range 11 – 37 20 – 66 32 – 105 42 – 135 56 – 180 75 – 240 95 – 304 112 – 360 131 – 420
Horsepower Rating @ 60 hz  300 500 900 1,100 1,500 2,100 2,600 3,100 3,600
Max. kW Rating @ 50 hz  292 521 828 1,065 1,420 1,893 3,219 2,840 3,313
Dimensions — Power Module
Width in Inches (mm) 17.4 (441.2)
Height in Inches (mm) 48.4 (1227.6)
Depth in Inches (mm) 9.8 (249.2)
Weight in Lbs. (kg) 300 (136.6)
Dimensions — Control Module
Width in Inches (mm) 4.41 (112.1)
Height in Inches (mm) 7.83 (199.0)
Depth in Inches (mm) 3.41 (86.8)
Weight in Lbs. (kg) 5.8 (2.6)
General Information
Bypass Mechanical Life 10M
Insulating Voltage Ui 5,000
Ramp Time Range .5 – 180 Seconds (.5 -360 Seconds Extended Ramp)
Resistance to Vibration Operational: 1g in each axis per IEC 68-2-6
Non-operational: 2.5g in each axis per IEC 68-2-6
Resistance to Shock Operational: 2.5g in each axis per IEC 68-2-27
Non-operational: 5.5g in each axis per IEC 68-2-27
Electrical Information
Operating Voltage 4,800
Operating Frequency 47 – 63 Hz
Overload Setting 30 – 100%
Trip Class 5, 10, 20 & 30
Control Wiring
Wire Sizes in AWG 22 – 12
Number of Conductors (Stranded) 2 (or one 14 AWG)
Torque Requirements in lb-in 3.5
Solid, Stranded or Flexible Max. 4.0 mm2
(Size in mm2)
Control Power Requirements
Voltage Range (24V ± 1%) 21.6 – 26.4
Steady State Current Amps 4.6
Inrush Current Amps 21
Ripple 1%
Relays (1) Class A and C
Voltage AC — maximum 240
Voltage DC — maximum 120
Amps — maximum 3
Environment
Temperature — Operating -30 – 40°C (No Derating) Consult factory for operation > 40°C
Temperature Storage -50 – 70°C
Altitude 2,000 meters (without derating) Consult factory for operation > 2,000 meters
Humidity < 95% non-condensing
Operating Position Any
Pollution Degree IEC947-1 3
Impulse withstand Voltage 60 kV
IEC947-4-1
 Based on 300% max. current, 15 second ramp, 4 starts per hour and 40°C ambient temperature.

CA03902002E For more information visit: www.eaton.com


22 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Table 27. C-Frame - 7,500V AC


Soft Starter SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811 SMV811
(Partial Catalog Number) B37 B66 B10 B13 B18 B24 B30 B36 B42
Ratings
Max. Current 37 66 105 135 180 240 304 360 420
Max. Voltage 7,500 7,500 7,500 7,500 7,500 7,500 7,500 7,500 7,500
FLA Current Range 11 – 37 20 – 66 32 – 105 42 – 135 56 – 180 75 – 240 95 – 304 112 – 360 131 – 420
Horsepower Rating @ 60 hz  400 700 1,250 1,600 2,100 2,800 3,600 4,200 5,000
Max. kW Rating @ 50 hz  392 699 1,112 1,429 1,906 2,541 3,219 3,812 4,447
Dimensions — Power Module
Width in Inches (mm) 17.4 (441.2)
Height in Inches (mm) 72.6 (1841.4)
Depth in Inches (mm) 9.8 (249.2)
Weight in Lbs. (kg) 450 (204.9)
Dimensions — Control Module
Width in Inches (mm) 4.41 (112.1)
Height in Inches (mm) 7.83 (199.0)
Depth in Inches (mm) 3.41 (86.8)
Weight in Lbs. (kg) 5.8 (2.6)
General Information
Bypass Mechanical Life 10M
Insulating Voltage Ui 5,000
Ramp Time Range .5 – 180 Seconds (.5 -360 Seconds Extended Ramp)
Resistance to Vibration Operational: 1g in each axis per IEC 68-2-6
Non-operational: 2.5g in each axis per IEC 68-2-6
Resistance to Shock Operational: 2.5g in each axis per IEC 68-2-27
Non-operational: 5.5g in each axis per IEC 68-2-27
Electrical Information
Operating Voltage Up to 7,500V
Operating Frequency 47 – 63 Hz
Overload Setting 30 – 100%
Trip Class 5, 10, 20 & 30
Control Wiring
Wire Sizes in AWG 22 – 14
Number of Conductors (Stranded) 2 (or one 14 AWG)
Torque Requirements in lb-in 3.5
Solid, Stranded or Flexible Max. 4.0 mm2
(Size in mm2)
Control Power Requirements
Voltage Range (24V ± 1%) 21.6 – 26.4
Steady State Current Amps 6.9
Inrush Current Amps 31.5
Ripple 1%
Relays (1) Class A and C
Voltage AC — maximum 240
Voltage DC — maximum 120
Amps — maximum 3
Environment
Temperature — Operating -30 – 40°C (No Derating) Consult factory for operation > 40°C
Temperature Storage -50 – 70°C
Altitude 2,000 meters (without derating) Consult factory for operation > 2,000 meters
Humidity < 95% non-condensing
Operating Position Any
Pollution Degree IEC947-1 3
Impulse withstand Voltage 60 kV
IEC947-4-1
 Based on 300% max. current, 15 second ramp, 4 starts per hour and 40°C ambient temperature.

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 23
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Dimensions
SMV811A – 2,500V AC
Applies to SMV, TMV and AMV Catalog prefixes.
The SMV811 can be mounted in any orientation except with the power pole cover facing down.

Rad.
12.60 (320.0) .20 (5.0)
16 Places Dia. .37 (9.3)
1.57 (40.0) .40 (10.0) Ref.
Dia. 6.30 (160.0) 13 Places

.61
(15.4)

23.80
(604.5)
20.39
22.00 (517.9)
(358.7)

5.22
(132.5)
Ref.

6.30 (160.0) 1.00 (25.4)


12.60 (320.0)
17.37 (441.2) 7.39 (187.7)
Ref.
8.45 (214.7)
Ref.

9.81
(249.2)

Figure 8. SMV811A — 2,500V AC — Approximate Dimensions in Inches (mm)

CA03902002E For more information visit: www.eaton.com


24 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

SMV811B – 5,000V AC
Applies to SMV, TMV and AMV Catalog prefixes.
The SMV811B consists of two power module assemblies that are wired in series. Unit 1 is always wired on the load side, unit
2 is always wired on the line side. The two power module assemblies can be mounted in a variety of configurations as long as
the minimum spacing between units is observed. Some examples are shown in Figures 9 – 11.
Configuration 1

.20 (5.0) 12.60 (320.0)


Radius .37 (9.3)
(6 Places) 6.30 Ref.
1.57 (40.0)
Dia. (160.0)
.63 (16.0)
Dia.
(3 Places)
.63
(15.9)

22.00 23.88
(558.7) (606.5)

49.75 46.35
(1263.7) (1177.2)

2.00
(50.8)
25.88
(657.3)

20.47
(519.9)

5.22
(132.5)
Ref.

17.37 (441.2) 1.59 (40.5)


Center of Plug
6.60
(167.7)
Ref.
8.53
(216.7)
9.81 Ref.
(249.2)

Figure 9. Configuration 1 of SMV811B — Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 25
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Configuration 2

12.60 .20 (5.0) Radius


(320.0) (6 Places) .37
1.57 6.30 (9.3)
(40.0) (160.0) .63 (16.0) Dia. Ref.
Dia. (3 Places)

.63
(15.9)

23.88
(606.5)

22.00 20.47
(558.7) (519.9)

5.22
(132.5)
Ref.

1.59 (40.5)
17.37 2.00 Center
(441.2) (50.8) of Plug

19.37 6.30 6.60


(492.0) (160.0) (167.7)
Ref. Ref.
36.74 8.53
(933.2) (216.7)
Ref.

9.81
(249.2)

Figure 10. Configuration 2 of SMV811B — Approximate Dimensions in Inches (mm)

CA03902002E For more information visit: www.eaton.com


26 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Configuration 3

.20 (5.0) 12.60


Radius (320.0) .37
(6 Places) 1.57 6.30 (9.3)
(40.0) (160.0) Ref.
.63 (16.0)
Dia. Dia.
(3 Places)

.63
(15.9)

23.88
(606.5)

22.00 20.47
(558.7) (519.9)

5.22
(132.5)
Ref.

1.59 (40.5)
Center 2.00
17.37 (50.8)
(441.2) of Plug

6.60
(167.7)
Ref.
8.53
(216.7)
9.81 Ref.
(249.2)

Figure 11. Configuration 3 of SMV811B — Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 27
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

SMV811C - 7,500V AC
The SMV811C consists of three power module assemblies that are wired in series. The three power module assemblies can be
mounted in a variety of configurations as long as the minimum spacing between units is observed. Some examples are
shown in Figures 12 – 14.
Configuration 1

.20 (5.0) 12.60 (320.0)


Radius .37 (9.3)
(6 Places) 6.30 Ref.
1.57 (40.0)
Dia. (160.0)
.63 (16.0)
Dia.
(3 Places)
.63
(15.9)

22.00 23.88
(558.7) (606.5)

49.75 46.35
(1263.7) (1177.2)

2.00
(50.8)
25.88
(657.3)

20.47
(519.9)

5.22
(132.5)
Ref.

17.37 (441.2) 1.59 (40.5)


6.60 Center of Plug
(167.7)
Ref.
8.53
(216.7)
9.81 Ref.
(249.2)

Figure 12. Configuration 1 of SMV811C — Approximate Dimensions in Inches (mm)

CA03902002E For more information visit: www.eaton.com


28 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Configuration 2

12.60 .20 (5.0) Radius


(320.0) (6 Places) .37
1.57 6.30 (9.3)
(40.0) (160.0) .63 (16.0) Dia. Ref.
Dia. (3 Places)

.63
(15.9)

23.88
(606.5)

22.00 20.47
(558.7) (519.9)

5.22
(132.5)
Ref.

1.59 (40.5)
17.37 2.00 Center
(441.2) (50.8) of Plug

19.37 6.30 6.60


(492.0) (160.0) (167.7)
Ref. Ref.
36.74 8.53
(933.2) (216.7)
Ref.

9.81
(249.2)

Figure 13. Configuration 2 of SMV811C — Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 29
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Configuration 3

.20 (5.0) 12.60


Radius (320.0) .37
(6 Places) 1.57 6.30 (9.3)
(40.0) (160.0) Ref.
.63 (16.0) Dia.
Dia.
(3 Places)

.63
(15.9)

23.88
(606.5)

22.00 20.47
(558.7) (519.9)

5.22
(132.5)
Ref.

1.59 (40.5)
Center 2.00 2.00
17.37 (50.8) (50.8)
(441.2) of Plug

6.60
(167.7)
Ref.
8.53
(216.7)
9.81 Ref.
(249.2)

Figure 14. Configuration 3 of SMV811C — Approximate Dimensions in Inches (mm)

CA03902002E For more information visit: www.eaton.com


30 Reduced Voltage Motor Starters
Solid-State Starters
October 2008
Type MV811, Intelligent Technologies (IT.) Medium Voltage Soft Starters

Control Module

10.68
(271.4) 0.41
8.66 (0.3)
(220.0)
MTG Holes for (4)
M8 or 5/16 Screws

20.47
(520.0)
18.10
(459.7)

11.02 5.12
(280.0) (130.0)

Control Panel Assembly

Figure 15. Control Module — Approximate Dimensions in Inches (mm)

For more information visit: www.eaton.com CA03902002E


Reduced Voltage Motor Starters 31
October 2008

CA03902002E For more information visit: www.eaton.com


Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
PowerChain Management
Eaton.com is a trademark of Eaton
Corporation. All other
trademarks are property
of their respective owners.

© 2008 Eaton Corporation


All Rights Reserved
Printed in USA
Publication No. CA03902002E / Z7590
October 2008

Вам также может понравиться