Вы находитесь на странице: 1из 1

CONCRETE CULVERT DESIGN AND DETAILING MANUAL

2003 03 14 CULVERT DETAILS Page 159

TABLE 8-6 RETAINING WALL DETAILS

300mm UP TO 1.8m HEIGHT


400mm OVER 1.8m HEIGHT 1 A 15006
2 15M @ 300 C/C

75mm Ø WALL DRAIN


100

AT 3000mm C/C A 15007


FORMED W/ NON-METALLIC A 15008
15M @ 250mm
MATERIAL 15M @
LAPS WITH A 005
300mm C/C

0.05m³ OF 19.0mm CLEAR STONE


H

FOR EACH DRAIN IN


300

B ACCORDANCE WITH OPSS 1004,


COMPLETELY WRAPPED WITH
GEOTEXTILE AND SECURELY TIED
A 005
150mm x 50mm KEY A 15002
1200
MIN

600

400 100 25
300

A 15001
A 15003
15M @ 300mm C/C
A 15M @ 300mm C/C
A 15004
15M @ 300mm C/C

H DIMENSIONS REINFORCING BAR DETAILS

(m) A15002 A15003 A15004 A 005 A15006 A15007

A B C/C LGTH LGTH LGTH SIZE C/C B C D LGTH LGTH

1.2 1200 400 250 1100 1100 2000 15 250 1340 470 300 - -
1.8 1600 400 250 1500 1500 1290 15 250 1940 470 300 1750 -
2.4 2100 700 250 2000 2000 1290 20 250 2540 470 300 2350 -
3.0 2600 800 200 2500 2500 1290 15 125 1690 470 300 2950 1990

NOTES: Footing dimensions are based on an allowable


soil capacity of 180 kPa @ SLS and 300 kPa B
@ ULS. R = 300
Reinforcing steel shall be grade 400 unless
otherwise noted.
Clear cover to reinforcing steel is 70 ± 20mm C
unless otherwise noted. D
Dimensions in millimeters, unless otherwise
noted. DETAIL OF BAR TYPE A 005
Designed according to 2000 CHBDC

Вам также может понравиться