Вы находитесь на странице: 1из 8

PROJECT :

CLIENT :
JOB NO. : DATE :
Wood Joist Design Based on NDS 2018, ICC PFC-4354 & PFC-5803

INPUT DATA & DESIGN SUMMARY AVAILABLE MINIMUM Dou


JOIST SPAN L= 35 ft
DEAD LOAD DL = 22 psf, (w/o self Wt) AVAILABLE MINIMUM TJI
LIVE LOAD / SNOW LL = 16 psf
JOIST SPACING S= 24 in o.c. AVAILABLE MINIMUM SSI
DURATION FACTOR CD = 1.25 (NDS Tab. 2.3.2)
REPETITIVE FACTOR Cr = 1.15 (NDS 4.3.9. For DSA, 1.0)
DEFLECTION LIMIT OF LIVE LOAD DLL = L / 360 ( L / 360 , 1.2 in )
DEFLECTION LIMIT OF LONG-TERM LOAD D1.5(DL+0.33LL) = L / 480 ( L / 480 , 0.9 in )
DEFLECTION LIMIT OF TOTAL LOAD D(DL+LL) = L / 240 ( L / 240 , 1.8 in )

ANALYSIS
JOIST PROPERTIES & ALLOWABLE MOMENT & SHEAR
2x No. 2, Douglas Fir-Larch ( ASD Supplements, Tab. 5.4a) 2x No. 1, Douglas Fir-Larch (f
Deep (in) Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106 Deep (in)
(CF included) (in2-lbs)
4 1.00 344 630 9 4
6 2.00 738 990 33 6
8 2.00 1183 1310 76 8
10 3.00 1767 1670 158 10
12 4.00 2375 2030 285 12

2x Structural, Douglas Fir-Larch (ASD Supplements, Tab. 5.4a)


Deep (in) Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106
(CF included) (in2-lbs) Where:
4 1.00 574 630 10 1. ASD Supplements, Tab. 5.4
6 2.00 1225 990 40 2. Assume that the joist top is
8 2.00 1975 1310 91 3. WoodBeam.xls is at www.
10 3.00 2942 1670 188
12 4.00 3958 2030 338

TJI/L65 ( from Trusjoist # 1062, page 5) SSI 32MX ( from ICC PFC-5803
Deep (in) Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 10 6
Deep (in)
(in2-lbs)
11 7/8 3.30 6750 1925 450 11 7/8
14 3.60 8030 2125 666 14
16 3.90 9210 2330 913 16
18 4.20 10380 2535 1205 18
20 4.40 11540 2740 1545 20
22 4.70 12690 2935 1934 22
24 5.00 13830 3060 2374 24
26 5.30 14960 2900 2868 26
28 5.50 16085 2900 3417 28
30 5.80 17205 2900 4025 30

TJI/L90 ( from Trusjoist # 1062, page 5) SSI 42MX ( from ICC PFC-5803
Deep (in) Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 10 6
Deep (in)
(in2-lbs)
11 7/8 4.20 9605 1925 621 11 7/8
14 4.50 11430 2125 913 14
16 4.70 13115 2330 1246 16
18 5.00 14785 2535 1635 18
20 5.30 16435 2740 2085 20
22 5.60 18075 2935 2597 22
24 5.80 19700 3060 3172 24
26 6.10 21315 2900 3814 26
28 6.40 22915 2900 4525 28
30 6.60 24510 2900 5306 30

TJI/H90 ( from Trusjoist # 1062, page 5) SSI 43L ( from ICC PFC-5803,
Deep (in) Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 10 6
Deep (in)
(in2-lbs)
11 7/8 4.60 10960 1925 687 11 7/8
14 4.90 13090 2125 1015 14
16 5.20 15065 2330 1389 16
18 5.40 17010 2535 1827 18
20 5.70 18945 2740 2331 20
22 6.00 20855 2935 2904 22
24 6.30 22755 3060 3549 24
26 6.50 24645 2900 4266 26
28 6.80 26520 2900 5059 28
30 7.10 28380 2900 5930 30
DESIGN EQUATIONS

wL2 wL 5w L 4
M  V  D DFL 
8C D C r 2C D C r 384 EI
( from Trusjoist # 1062, page 21)
22.5w L 4 2.26w L 2
D TJI  
EI d  105
( from ICC PFC-5803, page 2)

5w L 4 wL2
D SSI  
384 EI & DEFLECTIONS
CHECK JOIST CAPACITIES C

2x No. 2, Douglas Fir-Larch 2x No. 1, Douglas Fir-Larch


Deep (in) M (ft-lbs) V (lbs) DLL DLT DD+L CHECK Deep (in)
(in) (in) (in)
4 8202 937 120.05 312.66 288.87 N.G. 4
6 8309 950 32.74 86.80 79.81 N.G. 6
8 8309 950 14.22 37.69 34.65 N.G. 8
10 8415 962 6.84 18.45 16.88 N.G. 10
12 8522 974 3.79 10.41 9.48 N.G. 12

2x Structural, Douglas Fir-Larch


Deep (in) M (ft-lbs) V (lbs) DLL DLT DD+L CHECK
(in) (in) (in)
4 8202 937 108.05 281.39 259.98 N.G.
6 8309 950 27.01 71.61 65.84 N.G.
8 8309 950 11.87 31.48 28.94 N.G.
10 8415 962 5.75 15.51 14.19 N.G.
12 8522 974 3.20 8.77 7.99 N.G.

TJI/L65 SSI 32MX


Deep (in) M (ft-lbs) V (lbs) DLL DLT DD+L CHECK Deep (in)
(in) (in) (in)
11 7/8 8447 965 2.48 6.71 6.13 N.G. 11 7/8
14 8479 969 1.69 4.60 4.19 N.G. 14
16 8511 973 1.24 3.39 3.09 N.G. 16
18 8543 976 0.95 2.61 2.37 N.G. 18
20 8564 979 0.74 2.06 1.87 N.G. 20
22 8596 982 0.60 1.66 1.51 N.G. 22
24 8628 986 0.49 1.37 1.25 N.G. 24
26 8660 990 0.41 1.15 1.04 N.G. 26
28 8682 992 0.35 0.98 0.89 N.G. 28
30 8713 996 0.30 0.84 0.76 o.k. 30

TJI/L90 SSI 42MX


Deep (in) M (ft-lbs) V (lbs) DLL DLT DD+L CHECK Deep (in)
(in) (in) (in)
11 7/8 8543 976 1.81 5.00 4.55 N.G. 11 7/8
14 8575 980 1.25 3.45 3.14 N.G. 14
16 8596 982 0.92 2.56 2.33 N.G. 16
18 8628 986 0.71 1.98 1.80 N.G. 18
20 8660 990 0.56 1.58 1.43 N.G. 20
22 8692 993 0.46 1.29 1.16 N.G. 22
24 8713 996 0.38 1.07 0.97 N.G. 24
26 8745 999 0.32 0.90 0.81 N.G. 26
28 8777 1003 0.27 0.77 0.70 o.k. 28
30 8799 1006 0.23 0.67 0.60 o.k. 30

TJI/H90 SSI 43L


Deep (in) M (ft-lbs) V (lbs) DLL DLT DD+L CHECK Deep (in)
(in) (in) (in)
11 7/8 8586 981 1.65 4.57 4.15 N.G. 11 7/8
14 8618 985 1.13 3.14 2.85 N.G. 14
16 8650 989 0.83 2.33 2.11 N.G. 16
18 8671 991 0.64 1.80 1.63 N.G. 18
20 8703 995 0.51 1.43 1.30 N.G. 20
22 8735 998 0.41 1.17 1.06 N.G. 22
24 8767 1002 0.34 0.97 0.88 N.G. 24
26 8788 1004 0.29 0.82 0.74 o.k. 26
28 8820 1008 0.25 0.71 0.63 o.k. 28
30 8852 1012 0.21 0.61 0.55 o.k. 30
PAGE :
DESIGN BY :
REVIEW BY :

AVAILABLE MINIMUM Douglas Fir-Larch SIZES

AVAILABLE MINIMUM TJI SIZES


30" TJI/L65 28" TJI/L90 26" TJI/H90
AVAILABLE MINIMUM SSI SIZES
28" SSI 42MX 26" SSI 43LX

( L / 360 , 1.2 in )
( L / 480 , 0.9 in )
( L / 240 , 1.8 in )

2x No. 1, Douglas Fir-Larch (from WoodBeam.xls)


Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106
(CF included) (in2-lbs)
1.00 383 630 9
2.00 819 990 35
2.00 1314 1305 81
3.00 1961 1665 168
4.00 2637 2025 303

ASD Supplements, Tab. 5.4a is from American Wood Council, 2015.


Assume that the joist top is fully lateral supported by diaphragm. (C L = 1.0)
WoodBeam.xls is at www.engineering-international.com

SSI 32MX ( from ICC PFC-5803, page 5 & 6)


Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106 C x 106
(in2-lbs) (in2-lbs)
3.10 5391 2115 460 9.39
3.30 6570 2330 667 10.99
3.60 7684 2530 900 12.50
3.90 8800 2735 1170 14.02
4.10 9918 2935 1478 15.55
4.40 11038 3135 1824 17.08
4.70 12159 3335 2211 18.62
5.00 13279 3540 2638 20.15
5.20 14401 3740 3106 21.68
5.50 15524 3940 3616 23.21

SSI 42MX ( from ICC PFC-5803, page 5 & 6)


Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106 C x 106
(in2-lbs) (in2-lbs)
3.80 7592 2060 637 9.54
4.10 9274 2350 924 11.15
4.30 10863 2620 1246 12.68
4.60 12456 2895 1617 14.22
4.90 14051 3165 2040 15.77
5.10 15649 3440 2514 17.32
5.40 17248 3710 3042 18.87
5.70 18849 3985 3622 20.42
6.00 20450 4255 4257 21.97
6.20 22052 4530 4948 23.53

SSI 43L ( from ICC PFC-5803, page 5 & 6)


Wt (lbs/ft) M (ft-lbs) V (lbs) EI x 106 C x 106
(in2-lbs) (in2-lbs)
4.60 9789 2080 707 6.81
4.90 12081 2260 1031 7.91
5.20 14251 2425 1394 8.97
5.40 16269 2590 1944 10.05
5.70 18419 2755 2454 11.13
5.90 20573 2920 3026 12.21
6.20 22730 3090 3661 13.30
6.40 24889 3255 4358 14.39
6.70 27050 3420 5119 15.47
7.00 29212 3585 5944 16.56
(cont'd)

5w L 4
D DFL 
384 EI

2x No. 1, Douglas Fir-Larch


M (ft-lbs) V (lbs) DLL DLT DD+L CHECK
(in) (in) (in)
8202 937 120.05 312.66 288.87 N.G.
8309 950 30.87 81.84 75.25 N.G.
8309 950 13.34 35.36 32.51 N.G.
8415 962 6.43 17.35 15.88 N.G.
8522 974 3.57 9.79 8.91 N.G.

M (ft-lbs) V (lbs) DLL DLT DD+L CHECK


(in) (in) (in)
8426 963 2.40 6.48 5.93 N.G.
8447 965 1.66 4.51 4.12 N.G.
8479 969 1.24 3.38 3.08 N.G.
8511 973 0.96 2.62 2.39 N.G.
8532 975 0.76 2.09 1.91 N.G.
8564 979 0.62 1.71 1.56 N.G.
8596 982 0.51 1.43 1.30 N.G.
8628 986 0.43 1.21 1.10 N.G.
8650 989 0.37 1.04 0.94 N.G.
8682 992 0.32 0.90 0.81 N.G.
M (ft-lbs) V (lbs) DLL DLT DD+L CHECK
(in) (in) (in)
8500 971 1.75 4.77 4.35 N.G.
8532 975 1.21 3.33 3.03 N.G.
8554 978 0.90 2.49 2.27 N.G.
8586 981 0.70 1.94 1.77 N.G.
8618 985 0.56 1.56 1.41 N.G.
8639 987 0.46 1.28 1.16 N.G.
8671 991 0.38 1.07 0.97 N.G.
8703 995 0.32 0.91 0.82 N.G.
8735 998 0.28 0.78 0.71 o.k.
8756 1001 0.24 0.68 0.61 o.k.

M (ft-lbs) V (lbs) DLL DLT DD+L CHECK


(in) (in) (in)
8586 981 1.60 4.43 4.02 N.G.
8618 985 1.11 3.09 2.80 N.G.
8650 989 0.83 2.32 2.10 N.G.
8671 991 0.60 1.69 1.53 N.G.
8703 995 0.48 1.36 1.23 N.G.
8724 997 0.40 1.12 1.01 N.G.
8756 1001 0.33 0.94 0.85 N.G.
8777 1003 0.28 0.80 0.72 o.k.
8809 1007 0.24 0.69 0.62 o.k.
8841 1010 0.21 0.61 0.55 o.k.

Вам также может понравиться