SOLID SLABS
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC
OUTPUT D&D: Main beam 1st Floor @internal supportFAILS on Min Tension Spacing.
d = 500 - 50 - 12/2 = 444.0 mm
(3.4.4.4) K' = 0.156 < K = 0.162 compression steel required
(3.4.4.4) z = 444.0(0.5 + (0.25 - 0.156/0.893)^½ ) = 345.1 < 421.8 mm
(3.4.4.4) x = (444.0 - 344.1) /0.45 = 222.0 mm
d' = 50 + 12/2 = 56.0 mm .
(Fig 3.3) Gross fsc = 400.0 N/mm² from strain diagram .
(Fig 3.3) net fsc = 400.0 - 0.67 x 25 /1.5 = 388.8 > 0 N/mm²
Excess M = M - Mu = 200.0(0.162 - 0.156) /0.162 = 8.1 kNm
As' = 8.1E6 /388.8 /(444.0 - 56.0) = 53 mm²
PROVIDE 3X12 compression steel = 339 mm² .
(Fig 3.3) fst = 400.0 N/mm² .
As = (8.1E6 /388.0 + 191.9E6 /344.1) /400.0 = 1446 m .
PROVIDE 13X12 tension steel = 1470 mm² .
(Eqn 8) fs = 2/3 x 460 x 1,446 /1,470 = 301.7 N/mm²
(Table 3.11) Comp mod factor = 1 + 0.306 /(3 + 0.306) = 1.092 < 1.5
(Table 3.10) Tens mod factor = 0.55 + (477 - 301.7) /120 /(0.9 + 4.058) = 0.845 < 2
(3.4.6.3) Permissible L/d = 7.0 x 1.092 x 0.845 = 6.459
(3.4.6.1) Actual L/d = 1200 /444.0 = 2.703 ok .
ELEMENT DESIGN to BS 8110:2005
SIMPLE TEE & L BEAMS
Originated from RCC11.xls v4.0 © 2006 - 2010 TCC
Notes
9 Stresses in N/mm2
Compression +ve
7 1
- - - Neutral axis
Disclaimer
All advice or information from MPA-The Concrete Centre is intended for those who will evaluate the significance and limitations of its contents
and take responsibility for its use and application. No liability (including that for negligence) for any loss resulting from such advice or
information is accepted by MPA-The Concrete Centre or its subcontractors, suppliers or advisors. Users should note that all MPA-The Concrete
Centre software and publications are subject to revision from time to time and they should therefore ensure that they are in possession of the
latest version.
This spreadsheet should be used in compliance with the accompanying publication 'User Guide RC Spreadsheets: v4' available from The
Concrete Centre www.concretecentre.com/rcdesign Tel +44 (0)1276 606800
Status of spreadsheet This spreadsheet is shareware but may not be used for commercial purposes until the user has
Public release version. registered with The Concrete Centre using the licence validation form available on The
Concrete Centre website www.concretecentre.com/rcdesign
Revision history RCC11 Element Design.xls
13-May-09 RCC11 v3.6 bf used instead of bw for compression steel modification factor on TEE-BEAM. 328
24-Nov-00 RCC11 v1.3 SHEAR:C19 & C20 reformatted, and lateral link spacing check added (C Braidwood). 185
30-May-00 RCC11 v1.2 R Lawson comments incorporated (gc refs etc). 183