Вы находитесь на странице: 1из 4

GREASE-LINE

FLOW MAINTENANCE SYSTEM


THERMAL BUILDING SOLUTIONS WWW.PENTAIRTHERMAL.COM
RAYCHEM GREASE-LINE The Raychem self-regulating heating cable keeps
total operating costs down by adjusting power
FLOW MAINTENANCE SYSTEM output in response to ambient temperatures.
The cable’s output is
KEEPS LINES FREE FLOWING reduced automatically
as the pipe warms, so
there is no possibility
Greasy waste lines are pipes used for the disposal of failure due to
of waste oils and fats from kitchens and catering overheating.
facilities. Thermal insulation of the pipes is often
insufficient to keep greasy water free flowing in Our heat-tracing
the lines in many cases. Pentair Thermal Building system includes
Solutions offers the Raychem electric heat-tracing the heating cable, power connection, splices,
system providing flow-maintenance for greasy waste tee connections, controls, contactors, power
lines for both above-ground and buried piping. distribution panels, accessories, and the tools
necessary for a complete installation.

BENEFITS & TECHNOLOGY

• Reliable, Efficient ground or on insulated buried How self-regulation works in Raychem conductive-polymer heaters:
Temperature Control pipes without any risk of over
The line sensing thermostat or under-heating.
RAYSTAT-CONTROL-10 is • Safety
designed to provide user friendly
Pentair requires the use of
measurement and control for
a 30-mA residual current
heating cables. The thermostat
protective device (RCD) to
comes with a 25-A control relay provide maximum safety and Cold Pipe: Warm Pipe: Hot Pipe:
and a 2-A voltage free, alarm relay. protection from fire. In response to cold, the core or In response to warmth, the The core or fiber expands
Parameters and alarm conditions fiber contracts microscopically core or fiber begins to expand enough to disrupt almost
are shown on the display. • Cost Savings opening up electrical paths. microscopically disrupting all of the electrical paths.
the electrical paths.
Installing Raychem heating
• Simple Design cable on greasy waste
Raychem self-regulating heat- disposal lines eliminates Fatty
trace cables can be installed on Oil & Grease (FOG) congealing
metal or plastic pipes and can be on the interior of the piping,
wrapped around valves and heat and avoids costly drain
sinks. They can be installed above cleaning charges.
HOW DOES IT WORK?

Raychem self-regulating heat- Flow maintenance involves heating a The greasy waste lines must exit the
fluid in order to lower its viscosity so building to an exterior grease trap, and
trace cables with modified that it can be moved through a pipe or must be kept at a certain temperature
polyolefin outer jacket maintain a a tank. alonge the entire distance to keep the
FOG from concealing.
wide range of fluid temperatures in A grease-line flow maintenance
system is designed to maintain 40°C Typical applications include:
a variety of applications, including (104°F) fluid temperature to keep the • Greasy waste lines in commercial
greasy waste disposal lines. Fat, Oil and Grease mixture (FOG) in restaurants
suspension from the kitchen to the • Pre-wash stations
grease interceptor. • Floor drains.

Junction
box
RAYSTAT-CONTROL-10
RAYSTAT-CONTROL-10
Electronic controller
Electronic controller

2
16-0
JB660 V
AC 6
IP6

Raychem JB16-02
CE20-01 Wall
End seal Conduit
Insulation Conduit for
temperature
sensor Ground

RTD PT100

JB
AC 16
Raychem JB16-02
IP 66 -0

Water-tight
66 0
V 2

Raychem FS-C-2X insulation


heating cable 16-0
JB660 V
2
AC 6
IP6

Ground Conduit
Raychem JB16-02 CE20-01
Junction box End seal
Raychem FS-C-2X
heating cable

JB
AC 16
IP 66
66 0 -0
V 2

Wall

TYPICAL ABOVE-GROUND PIPING SYSTEM TYPICAL BURIED PIPING SYSTEM

PROVEN TRACK RECORD


Project Name Location Application Details

Wyndam Hotel - Bonnet Creek Orlando, FL, USA Grease line to central interceptor

Disneyland Anaheim, CA, USA Restaurants to central interceptor

Hartsfield International Airport Atlanta, GA, USA Terminal D - Food Court

Niagara Outlet Mall Niagara, ON, USA 1400' piping

National Stadium Warsaw, Poland Grease line from food court to central interceptor

Galeria Katowice Shopping Center Katowice, Poland Grease line from food court to central interceptor

The Galleria, Al Maryah Island Abu Dhabi, UAE Retail food court areas to grease trap

FS-C-2X cables are approved by


APPROVALS BS/VDE/ÖVE/ERFA/CE
WWW.PENTAIRTHERMAL.COM

NORTH AMERICA EUROPE, MIDDLE EAST, AFRICA UAE NOIDA-INDIA MUMBAI-INDIA


Tel: +1.800.545.6258 Tel: +32.16.213.511 Tel: +971.4.378.1700 Tel: +91.120.464.9500 Tel: +91.22.6775.8800/01
Fax: +1.800.527.5703 Fax: +32.16.213.603 Fax: +971.4.378.1777 Fax: +91.120.464.9548 Fax: +91.22.2556.1491
Tel: +1.650.216.1526 thermal.info@pentair.com PTMinfome@pentair.com PTMinfome@pentair.com PTMinfome@pentair.com
Fax: +1.650.474.7711
thermal.info@pentair.com

All Pentair trademarks and logos are owned by Pentair or its global affiliates. Pentair reserves the right to change specifications without prior notice.

© 2014 Pentair.

THERMAL BUILDING SOLUTIONS EN-RaychemGreasyWaste-SB-H80903 10/14

Вам также может понравиться