Вы находитесь на странице: 1из 27

Aquaflair

Technical Cooling Chillers


Aquaflair
Technical Cooling Chillers

Schneider Electric policy is one of continuous technological innovation and the Company therefore reserves the right to amend any data herein without
prior notice. The images shown in this catalogue are for descriptive purposes only. They may therefore differ from specific models which are selected.
Some of the features described may be available only for some models or configurations. Please refer to the specific technical literature for further details.
AQUAFLAIR Cooling portfolio 4 5

Small Medium Large Extra-Large

Uniflair ERAC Uniflair BREC


Page 8 - 9 Page 14 - 15

Uniflair LRAC Uniflair ARAC
Cooling only Page 6 - 7 Page 12 - 13
Uniflair ISAC Uniflair BCEC
Page 10 - 11 Page 16 - 17

Air-cooled
units
Uniflair ERAH
Page 8 - 9

Uniflair LRAH Uniflair ARAH
Heat pumps Page 6 - 7 Page 12 - 13
Uniflair ISAH
Page 10 - 11

Uniflair ERAF Uniflair BREF


Page 18 - 19 Page 24 - 25

Free-cooling Uniflair ARAF
units Cooling only Page 22 - 23
Uniflair ISAF Uniflair BCEF
Page 20 - 21 Page 26 - 27

Uniflair BRWC
Page 28 - 29

Cooling only
Uniflair BCWC
Page 30 - 31
Water-cooled
and
condenserless
units Heat pumps Uniflair BRWH
Page 28 - 29

Uniflair BRRC
Condenserless Page 32 - 33

Uniflair ERCC
Page 34 - 35

Cooling only
Uniflair ISCC
Page 36 - 37

Uniflair ERCH
Page 34 - 35

Units with
Heat pumps
ducted fans
Uniflair ISCH
Page 36 - 37

Uniflair ERCF
Page 38 - 39

Free-cooling
Uniflair ISCF
Page 40 - 41

Uniflair UTAT
Fan-coil
Units for Page 42- 43
Underfloor Scroll Compressors Screw compressors
comfort
terminal units
applications Uniflair UTCT
Fan unit Oil free compressors Variable speed drive compressors
Page 44 - 45
6 7

Why Uniflair
Efficiency and Reliability Optimized management

The issue of energy continues to play an extremely important role regarding operating costs for modern systems. Management of the whole system allows energy consumption to be optimized and strategies of integrated control to
Uniflair’s range of products makes it possible to guarantee maximum service reliability while cutting energy be implemented which would otherwise not be possible.
consumption to a minimum:
Uniflair ‘s precision air conditioning units, Active Floor modules and chillers can be linked together by a LAN,
maximising the operating parameters and the real needs of the system.
Particular attention has been paid to the management logic which is aimed at reducing the energy requirement by
means of a “tracking logic” for the current thermal load.
Indirect free-cooling High efficiency refrigerants
The temperature of the chilled water varies dynamically in such a way as to minimize compressor consumption and
the use of free-cooling, maintaining the desired temperature within the room.

“Oil-free” centrifugal
Efficiency at partial loads compressors with 7.0
magnetic bearings 25
(tandem) 6.0 EER
20 Chilled water temperature

Water temperature [°C]


5.0

Energy Efficiency [%]


Modularity and flexibility 15
4.0

3.0
10
Inverter driven 2.0
compressors 5
Optimized set-point 1.0

0 0
Min. Load Medium Medium Max Load
Load Load

Number of operating units


Double screw
Less CO2
compressors

Advanced controls Acoustic Impact

Uniflair produces the software for its units internally. This enables the company to equip each machine with a “tailor Reduction in sound pollution is one of the most critical factors designers are called on to solve when choosing plant
made” control which manages all aspects of the unit. systems.

Absolute control means: Uniflair chillers offer low-noise solutions with extremely low acoustic impact thanks to:

• Acousti-composite fans with high efficiency and low acoustic impact


Precision: the units use advanced algorithms to accurately control the temperature of the • Fans with electronically commutated motor (EC) to reduce the acoustic impact at all load conditions
chilled water • Extra-large air side exchangers
• Specially devised and implemented algorithms which control the rotation speed of the fans
• Tested, optimised compressor insulation and housing
Reliability: each component is continuously monitored to guarantee it is always used
within operating limits and will signal any faults before breakdown occurs
74 Uniflair unit comparision (blue
72 line) with its main competitors
70
Local Area Network: Aquaflair chillers can “talk” to each other, resulting in excellent control

Noise pressure level [db(A)]


68
of multi-unit systems, managing all the cooling resources and units on stand-by (either on a
66 Acoustic levels for a basic high
time basis or alarm) capacity unit, Tambient: 35°C,
64
Twater in/out: 12/7°C, distance
Connectivity: Uniflair microprocessor controls can “talk” to the most common supervision 62
10 m, Q=2,condensing coil side
systems (Building Management Systems) including: Modbus, Bacnet, LonWorks, Trend, 60
Metasys, TCP/IP and SNMP 58
56
400 500 600 700 800 900 1000 1100 kW
8 9

Free-cooling Intelligent Free-cooling

When a system is used for technological or industrial Direct expansion mode The need to install a stand-by unit can be exploited
processes which operate all year round, it is important to increase the free-cooling capacity.
in terms of energy saving to use solutions which exploit By interconnecting the circuits of the free-cooling units
these conditions. Chillers equipped with free-cooling it is possible to make the water flow through all of the
Free-cooling coil
devices not only reduce energy consumption compared available exchangers therefore further decreasing energy
to traditional systems but also limit CO2 emissions into consumption.
the atmosphere, contributing therefore to reducing global
pump
Free-cooling pump warming. Additional annual energy saving
When the external temperature is low enough, the free- • Compared to traditional Free-cooling: up to 7%
evaporator cooling system produces chilled water using external air depending on the climate
only, significantly reducing energy consumption since it is • Compared to a traditional system: up to 50%
pump
limited to the fans. Mixed Mode

Annual energy saving

Traditional Free-Cooling Uniflair Free-Cooling Uniflair Free-cooling Vs


Uniflair Intelligent
Free-cooling
Energy saving [kWh] Economic saving

Frankfurt 34.560 -5%

Milan 29.132 -4%


Free-cooling mode
Paris 36.954 -4%

Amsterdam 42.558 -7%

Madrid 36.743 -4%

Berlin 31.525 -4%

London 46.018 -6%

Limits Benefits
• Pumps sized 24/7 to overcome resistance of Free-cooling • Main Pumps sized only to overcome resistance of
coil and the 3-way valve standard evaporator
• 3-way valve low reliability • Extremely reliable free-cooling pump
• No 3-way valve
Glycol-free
• Capacity with in-built free-cooling up to 1450 kW

Annual Standard Traditional Uniflair


1600
energy chiller Free- Free-
Annual Absorbed Power [MWh]

1400 saving cooling cooling Created for applications where the use of anti-
- 41% freeze solutions are not permitted, this solution,
Energy
1200 thanks to an intermediate heat exchanger,
absorbed MWh 1370445 994434 969760
- 6% Free-cooling coil isolates the principal hydraulic circuit from the
(yearly)
Standard Chiller

1000 free-cooling circuit.


Free-cooling

Free-cooling

Energy
Careful selection of the intermediate heat
Traditional

pump
saving % 0 38% 41%
exchanger allows the delta T to be limited to
Uniflair

800 (yearly)
Free-cooling pump only 2°C, reducing therefore the energy drops
600 Annual saving € €0 - € 41361 - € 44075 which are intrinsic to this system.

Typical IT Installation - London 24 hours, 7 days per week pump


operation / 10°C/15°C chilled water
evaporator
Payback period 8 months
Air-cooled water chillers and heat pumps with axial fans designed for outdoor installation 10 LRAC-LRAH 11

Uniflair LRAC-LRAH

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 6 ÷ 40 kW LRAC/LRAH MODELS 023B 032B 041B 054A 067A 090A 120A 137A 180A
12/7°C; external temperature
Heating capacity: 7 ÷ 43 kW Power supply V/ph/Hz 230 / 1 / 50 400 / 3 + N / 50
35°C; R410A refrigerant
Cooling capacity (1) kW 6 8 10 14 17 19 27 33 39
Available versions 2. Data refer to nominal
Absorbed power (1) kW 1,5 2,2 2,9 4,4 4,9 6,0 8,7 10,0 12,0
conditions: water temperature
- low noise C.O.P. (1) 4,0 3,6 3,5 3,2 3,5 3,3 3,1 3,2 3,2
40/45°C; external temperature
- Top Operating Performance Heating capacity (2) kW 6,7 9,0 10,9 15,5 18,9 22,1 30,2 36,7 43,5 7°C d.b. 6°C w.b.; R410A
- condensing version (*) Absorbed power (2) kW 1,7 2,3 2,8 3,9 4,7 5,5 8,5 10,0 11,9 refrigerant

Refrigerant R-410A Noise pressure level (3) dB(A) 34 34 34 35 37 38 38 40 41


3. Measured in free field at 10
Scroll Compressor/s Fans / poles nr. 1/6 1/6 1/6 1/6 2/6 2/6 2/6 3/6 4/6 mt. (Q=2, front) from the unit
Circuits / compressors nr. 1/1 1/1 1/1 1/1 1/1 1/1 1/2 1/2 1/2 running in nominal conditions
Compressor type Scroll
4. Data refer to empty unit
Evaporator Plate
Water tank l 25 25 25 50 50 50 100 100 100
DIMENSIONS AND WEIGHT
Height mm 650 650 650 1271 1271 1271 1271 1271 1271
Depth mm 458 458 458 458 458 458 615 615 615
Standard Features • Predisposition for cooling / heating systems with heating
Width mm 1274 1274 1274 1273 1273 1273 2054 2054 2054
• Designed with a minimal footprint panels
Weight (without hydronic kit) kg 100 101 103 152 160 162 262 272 282
• Self-supporting frame in galvanised steel (colour • Rubber anti-vibration feet
Weight (version with pump) kg 104 105 107 159 167 169 273 281 291
RAL7037) with panels varnished with epoxy powders in   
Weight (version with water
compliance with the ASTM B117 norm kg 116 117 119 179 187 189 300 308 318
tank and pump) (4)
• Between 1 to 2 hermetic Scroll compressors with Total Operating Performance
internal thermal protection and anti-vibration feet • Electronic expansion valve driven by the
• Crankcase heaters (*) microprocessor control
• Ecological refrigerant: R410A • Advanced UPCOxs microprocessor control system
• Refrigerant circuit in compliance with EC norms (PED with specific algorithm to:
97/23/ EC directive) in copper tubes mainly including - Outlet water temperature regulation
a filter dryer, water flow switch, thermostatic valve with - Advanced management of compressors run
external equalisation (stainless steel made) and high and through automatic set-point sensitivity regulation
low pressure switches - Advanced management of the de-frosting function
• Metal grille panel to protect the air side heat exchanger to minimise cycle inversions (*)
• Cycle inversion on the refrigerant side with 4-way - Advanced anti-freeze protection on evaporator
reversing valve (*) - Integrated LAN card for local network connection
• Stainless steel, brazed plate heat exchanger insulated of a group of chillers (up to 10 units, with 1 or 2
with closed-cell, expanded polyurethane stand-by units)
• Anti-freeze heater on evaporator (*) • Moreover, the microprocessor control system Construction Options Options
• Air side heat exchanger with aluminium fins and enables: • On-board water tank and pump • Remote user terminal for:
mechanicallyexpanded copper tubes - Remote cycle inversion (*) • High head pressure pump (*) - display / entering of commands
• Axial fans, statically and dynamically balanced, with - The set point adjustment by a 0-10V external • Condensing Unit (*) - display unit status and alarms
sickleblades and with safety protection grilles signal • Unit works down to - 20°C • Chilled / hot water piping filter
• Sound-proofing polymeric impeller for each fan - The management and selection of double set-point • Production of glycol water mixture at low temperatures
• Condensation control including continuous regulation of - Free contact for general alarm and 2 addressable option (down to - 10 °C)
fan speed alarms • Anti-freeze protection on evaporator, water tank and
• Electric panel conforming to EC Directive 2006 / 95 / EC - Remote ON-OFF control pump
and Directive EMC 2004/108/EC with auxiliary 12V circuit, - The ability to interface with main external • RS485 serial adaptor used to communicate with Uniflair
general cut-off switch, magneto-thermal protection cut-off communications protocols: Modbus, Bacnet, supervisory system or to interface with external BMS
switches • LON FTT10 serial adaptor used to communicate with

© 2012 Schneider Electric. All rights reserved.


Lonworks, Metasys, TCP/IP and SNMP
• UTS microprocessor control system with local user external BMS managed with LON protocol
control and monitoring terminal with LCD display and LED • Hot gas by-pass disposal for a constant outlet water
signals for all working parameters: chilled/hot (*) water temperature, even with 0 to 100% charge variation
(*) Optional for LRAC, when possible
temperature regulation, anti-freeze (optional; only LRAC)
protection, compressor timing and protection, fan speed • TCP/IP serial adaptor used to interface with external BMS
regulation, alarm code signalling, centralization for general • Condensing coils equipped with safety grilles and filter
alarm control and remote ON-OFF switch and remote
cycle inversion (*) (*) on request
• Water flow differential pressure switch

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
LRAC-LRAH 06/12
Air-cooled water chillers and heat pumps with axial fans for outdoor installations 12 ERAC - ERAH 13

Uniflair ERAC - ERAH

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 50 ÷ 110 kW ERAC/ERAH MODELS 0521A 0621A 0721A 0821A 0921A 0922A 1021A 1022A 1221A 1222A
12/7°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 0%; R410A
Refrigerant circuits nr. 1 1 1 1 1 2 1 2 1 2 refrigerant
- low noise Compressors nr. x mod 2 x Scroll
2. Data refer to the total
- ultra low noise Fans nr. 2 2 2 3 3 3 3 3 4 4
absorbed power (compressors
Evaporator nr. 1 1 1 1 1 2 1 2 1 2
Refrigerant R410A and fans)
Scroll Compressors Evaporator mod plate
3. Data refer to nominal
ERAC - Low noise version
conditions: water temperature
Cooling capacity (1) kW 47 56 65 75 83 83 96 95 111 111 40/45°C, external temperature
Absorbed power (1) kW 13,8 17,6 19,7 21,9 25,9 25,9 30,2 30,2 35,1 35,2 7°C dry bulb, 6°C wet bulb;
E.E.R. (2) 3,41 3,16 3,30 3,43 3,20 3,21 3,17 3,16 3,16 3,16 R410A refrigerant
E.S.E.E.R. (5) 5,23 5,16 5,40 5,44 5,26 5,10 5,49 5,28 5,38 5,37 4. Data measured in free
ERAH - Low noise version field at 10 metres from the
Heating capacity (3) kW 54 64 74 85 95 n.a. 111 n.a. 128 n.a. unit operating at nominal
Absorbed power (3) kW 14,6 17,6 19,8 22,8 26,0 n.a. 30,7 n.a. 35,8 n.a. conditions, coil side, Q=2
directional factor
C.O.P. (2) 3,71 3,64 3,74 3,73 3,64 n.a. 3,61 n.a. 3,58 n.a.
Standard Features discharge Noise pressure level (4) dB(A) 42,6 43,5 44,0 44,3 44,3 44,3 53,4 53,4 54,7 54,7 5. European Seasonal Energy
• Self supporting frame in galvanised steel with panels - Production of chilled water to -15°C ERAC - Ultra low noise version Efficiency Ratio
varnished with epoxy powders (colour RAL7037) - Anti-freeze protection Cooling capacity (1) kW 46 53 62 73 80 80 91 92 106 107 6. Data refer to an empty unit
• Access panel to the unit equipped with handles and fast - Compressor timing and protection Absorbed power (1) kW 14,2 18,4 20,7 22,8 27,2 27,2 31,9 31,9 36,9 37,0 without pump and water tank
screws - Compressor rotation based on FIFO logic E.E.R. (2) 3,20 2,90 3,01 3,19 2,93 2,93 2,87 2,87 2,89 2,90
• Two hermetic scroll compressors with internal thermal - Pump rotation on a timed basis for equal operation and E.S.E.E.R. (5) 5,21 5,07 5,25 5,38 5,16 4,99 5,39 5,12 5,29 5,22
protection, anti-vibration supports and crankcase heaters start-up of the stand-by pump (with alarm signal) in the ERAH - Ultra low noise version
(ERAH and low ambient temperatures version) event of a breakdown Heating capacity (3) kW 52 62 71 82 91 n.a. 107 n.a. 124 n.a.
• Single refrigerant circuit (*) conforming to EC Directives - Display of compressor operating hours Absorbed power (3) kW 14,8 17,9 20,7 23,3 26,4 n.a. 31,1 n.a. 35,7 n.a.
(PED 97/23/CE) in copper tubing including filter dryer, - Alarm code signal C.O.P. (2) 3,53 3,45 3,43 3,53 3,46 n.a. 3,43 n.a. 3,47 n.a.
liquid sight glass, dual flow thermostatic valve with - General alarm with clean signal contact Noise pressure level (4) dB(A) 39,1 39,8 40,3 40,1 40,1 40,1 49,6 49,6 51 51
external equalisation, high and low pressure switches and - ON-OFF remote control Dimensions and weights
high pressure transducers Height mm 1560 1560 1560 1560 1560 1560 1875 1875 1875 1875
• Environmentally friendly refrigerant R410A Depth mm 1190 1190 1190 1190 1190 1190 1190 1190 1190 1190
• Water side brazed plate heat exchanger in stainless Width mm 2010 2010 2805 2805 2805 2805 3075 3075 3075 3075
steel insulated with closed cell expanded polyurethane Total Operating Performance
Weight ERAC basic (6) kg 607 612 730 760 766 777 975 974 1003 1003
• Water flow differential pressure switch • Electronic expansion valve directly controlled by the
Weight ERAH basic (6) kg 632 637 760 790 797 n.a. 1019 n.a. 1047 n.a.
• Air side exchange coil with aluminium fins and unit microprocessor control
mechanicallyexpanded copper tubes • Advanced UpCO1m control for:
• Refrigerant side cycle inversion with 4-way inversion - Discharge water temperature regulation
valve (ERAH) - Management of the electronic thermostatic valve
• Acousti-composite fans: Sickle-blade axial fans, - Monitoring of the refrigerant load
statically and dynamically balanced and made from - Self-adjustment of the set-point regulation
composite materials for high efficiency and low acoustic - Advanced defrost operation management (ERAH) Construction Options heaters
impact with internal and external safety protection grilles - Integrated LAN card • Ultra low noise version via a specific algorithm and • Modification of the set point by external 0-10V signal
• Modulating condensation control based on the - Compatibility with the most common external BMS soundproofing of the compressors • Condensing unit (*)
condensation pressure systems and with the Modbus protocol using only • Partial / total condensation heat recovery
• Electrical panel conforming to EC Directives (2006/95/ the RS485 card • Integrated hydraulic module with one or two pumps (1 (*) on request
EC and EMC 2004/108/EC) protection grade IP54 with + 1 stand-by) with heat-protected circulation, expansion
auxiliary transformer, lockable general cut off switch, (*) ERAC models with **22A suffix are available with two vessel and safety valve Options
magneto-thermal cut off switches and remote control compressors on two circuits • Internal water tank • Remote user terminal

© 2012 Schneider Electric. All rights reserved.


• Sequence phase control • Internal water tank including a pump to manage the • Clock card
• Anti-condensation heaters for the electrical panel (ERAH primary circuit • RS485 serial card, FTT10 or TCP/IP for connection to
and low ambient temperature versions) • Power factor improvement compressors the Uniflair supervision system or an external BMS
• Microprocessor control system including: • Compressor Softstart • Metal filters and protection grilles for the condensing
- Local user terminal externally visible and accessible via • Cataphoresis treatment for the condensing coils coils
an access hatch • Shut off taps on the compressor discharge • Rubber or spring anti-vibration supports
- Chilled/hot water temperature regulation (ERAH) on the • Evaporator, water tank and pump group anti-freeze

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ERAC-ERAH 06/12
Air cooled modulating water chillers and heat pumps for outdoor installation 14 ISAC - ISAH 15

Uniflair ISAC - ISAH

Range Technical Data 1. Data refer to nominal


conditions: Inlet/outlet water
Cooling capacity: 60 ÷ 120 kW ISAC/ISAH MODELS 0621A 0921A 1221A
temperature: 12/7°C; external
Heating capacity: 66 ÷ 130 kW Power supply V/ph/Hz 400 / 3 / 50
temperature 35°C; glycol 0%;
Refrigerant circuits nr. 1 1 1 inverter compressor at 90rps
Available versions
Compressors nr. 1 ON/OFF + 1 inverter driven (Scroll) R410A refrigerant
- low noise Fans nr. 2 3 4
2. Data refer to total absorbed
Evaporator nr. 1 1 1
Refrigerant R-410A power (compressors and fans)
Inverter driven Scroll compressors Evaporator mod piastre
3. Data refer to nominal
ISAC – LOW NOISE VERSION
conditions: water 40/45°C,
Cooling capacity (1) kW 59 87 115 external temperature dry bulb:
Absorbed power (1)(2) kW 18,7 26,6 35,9 7°C, wet bulb: 6°C; inverter
E.S.E.E.R. (4) 5,66 5,71 5,72 compressor at 90rps R410A
I.P.L.V. (5) 6,19 6,27 6,22 refrigerant

ISAH – LOW NOISE VERSION 4. European Seasonal Energy


Heating capacity (3) kW 66 97 128 Efficiency Ratio
Absorbed power (3)(2) kW 18,1 26,2 35,9 5. Integrated Partial Load Value
Noise pressure level (6) dB(A) 43,5 44,3 54,7
6. Data measured in free field
Standard Features • Air side exchange coil with aluminium fins and DIMENSIONS AND WEIGHTS conditions at 10m from the
• Self-supporting galvanized sheet steel framework with mechanically expanded copper piping Height mm 1560 1560 1874 unit operating in nominal
panels painted with epoxy powder paints (colour RAL • Acousti-composite fans: Sickle-blade axial fans, Length mm 1190 1190 1192 conditions, coil side, directional
7037) equipped with fast screws for easy and quick statically balanced and made from composite material Width mm 2008 2798 3075 factor Q=2
access ensuring elevated efficiency and low noise, with external Weight ISAC (basic version) (7) Kg 652 810 1047 7. Data refer to an empty unit
• Inverter-driven hermetic Scroll compressor, equipped and internal protection grill Weight ISAH (basic version) (7) Kg 682 840 1092 without pump
with • Modulating condensation control by means of
- Inverter speed control continuous fan speed control
- Oil by-pass valve and line • Electrical panel in accordance with EC standards
- Soft start (directive 73/23/EC and directive EMC 89/336/EC) IP54
- Integrated power factor correction condenser protection grade with auxiliary transformer, minimum and
- Integrated thermal protection maximum temperature control, general door interlock cut
- Anti-vibration supports off switch, protection and remote control switches
• Inverter driver with IP54 protection grade coupled with • Phase sequence control
a specific compressor and positioned in a dedicated • UPC1m microprocessor control including:
housing compartment - Chilled / hot water temperature regulation by means of
• Hermetic Scroll compressor with integrated thermal self adaption of the set point regulation band
protection and anti-vibration feet - Management of the electronic thermostatic valve
• Compressor sound-proofing with noise insulating - Compressor management driven by inverter
jackets and, only for model 1221A, soundproofing of the - Quick start start-up procedure
compressor compartment - Integrated LAN card
• Vibration absorbers on the compressor discharge and - Integrated clock card
suction line (only for model 1221A) - Compatibility with Modbus protocol via RS485
• Single refrigerant circuit in accordance with EC - Compatability with the most common external BMS: Construction Options Options
standards (directive PED 97/23/CE) in copper piping LONworks, BacNET, TCP/IP, Trend • Integrated hydraulic module with one or two pumps • Remote user terminal mP20 II (up to 200 metres) for:
including dehydration filter, liquid sight glass, electronic (1+1 in stand-by) with heat protected circulation, - entering of commands
expansion valve connected to and driven by the unit expansion vessel and safety valve - display unit status and alarms
control, high and low pressure switches and transducers. • Integrated hydraulic module with one or two inverter • RS485 serial adaptor used to communicate with the
The refrigerant circuit features an exclusive patented driven pumps (1+1 in stand-by) with heat protected Uniflair supervisory system or to interface with external
system for optimum lubrification management of the circulation, expansion vessel and safety valve BMS
tandem compressors • Cataphoresis treatment for condensing coils • LON F T T10 serial adaptor used to communicate with

© 2012 Schneider Electric. All rights reserved.


• Continuous operation up to -20°C (only ISAC) • Shut-off taps on the compressor discharge external BMS managed with LON protocol
• Environmentally friendly refrigerant R410A • Power factor correction on compressors • TCP/IP serial adaptor used to communicate with
• Crankcase heaters and inverter with oil heating function • Modification of the set-point by external signal 0-10V external BMS managed with SNMP protocol
• Brazed plate water side heat exchangers in stainless • EC fans • Air side coil protection filters and grills
steel, insulated with closed-cell expanded polyurethane • Rubber or spring anti-vibration supports
and anti-freeze heaters
• Refrigerant side cycle inversion with 4-way inversion
valve (only ISAH)
• Water flow differential pressure switch

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ISAC-ISAH 06/12
Air-cooled water chillers and heat pumps with axial fans for outdoor installations 16 ARAC - ARAH 17

Uniflair ARAC - ARAH

Range Technical Data 1. Data refer to nominal

R407C
conditions: water temperature
Cooling capacity: 120 ÷ 260 kW ARAC / ARAH MODELS 0644A 0744A 0964A 1084A 1204A
12/7°C; external temperature
Heating capacity: 129 ÷ 285 kW Power supply V/ph/Hz 400 / 3 + N / 50
35°C; R407C refrigerant
Circuits / compressors nr. 2/4 2/4 2/4 2/4 2/4
Available versions 2. With pump group
Fans / poles nr. 2/6 3/6 3/6 4/6 4/6
- standard Evaporator type nr. x mod 1 x Shell &Tube 3. Measured in free field
- modulating condensation control Cooling only (ARAC) conditions, coil side, direction
- low-noise factor Q=2, at 10 mt. from the
Cooling capacity (1) kW 135 165 190 230 260
unit (at nominal conditions)
Refrigerant R-407C Absorbed power (1) kW 49 54 73 84 95
Heat pump (ARAH) 4. Data refer to nominal
Scroll Compressors conditions: water temperature
Heating capacity (4) kW 141 179 220 255 285
40/45°C, external temperature
Absorbed power (4) kW 41 64 79 84 85
7°C dry bulb, 6°C wet bulb;
Noise pressure level min/max (3) dB(A) 50 / 57 51 / 58 51 / 58 52 / 59 52 / 59 R407C refrigerant
Low noise version
5. Data refer to nominal
Cooling capacity (1) kW 128 158 180 219 245 conditions: recovery water
Absorbed power (1) kW 52 56 78 88 102 temperature 40/45°C; chilled
Noise pressure level (3) dB(A) 47 48 48 50 50 water temperature 12/7°C;
Standard Features - advanced defrost function (only for ARAH) Partial heat recovery (option) external temperature 35°C;
• Self-supporting frame in galvanised steel (colour - integrated LAN card for local network connection of Exchanger type nr. plate / 2 R407C refrigerant
RAL7037) with panels finished in epoxy powders a group of chillers (up to 10 units with 1or 2 units in Thermal heat recovery (5) kW 48 53 75 76 86 6. Data refer to empty unit
• Four hermetic Scroll compressors with internal thermal stand-by) Water flow l/h 8256 9116 12900 13072 14792
protection and anti-vibration supports • Moreover, the microprocessor control system permits: Total heat recovery (option)
• Two refrigerant circuits conforming to EC norms - an overlapped management of units as a single chiller Exchanger type nr. Shell &Tube / 2
(PED 97/23/CE) in copper tubes mainly including: filter (up to 10) Thermal heat recovery (5) kW 178 207 278 318 350
dryer, flow indicator, thermostatic valves with external - management of double set-point and selection Water flow l/h 30616 35600 47816 54696 60200
equalisation, high and low pressure switches and high - free-contact for general alarm and 2 addressable alarms Dimensions and weight
and low pressure transducer management Height mm 1618 2140 2140 2140 2140
• Compressor crankcase heaters (*) - remote ON-OFF switch Depth mm 3807 4542 4542 5242 5242
• Exchange of the cycle on the refrigerant side with 4-way - abilit y to interface with Modbus protocol directly on Width mm 1193 1344 1344 1344 1344
reversing valve (only for ARAH) RS485 serial card Weight (without hydronic kit) (6) kg 1271 1754 2001 2182 2290
• Shell & tube water/refrigerant heat exchanger with - ability to interface with main external communication Weight (with water tank and 2 pumps) kg 1554 2058 2321 2537 2648
two independent cooling side circuits and one hydraulic protocols: Bacnet, Lonworks, Metasys, TCP/IP and
circuit: the heat exchanger is insulated with closed-cell SNMP
expanded neoprene
• Heat exchanger coil with aluminium fins and (*) Standard only for ARAH
mechanically-expanded copper tubes
• Water flow pressure switch Construction Options supervision system or to interface with external BMS
• Sickle-blade axial fans, statically and dynamically • Standard version with modulating condensation control • Condensing coil cataphoresis treatment
balanced with safety protection grilles (internal and • Low noise version with modulating condensation control • R134a Refrigerant (*)
external) protection grade IP54 through special algorithm and sound-proofing of • Condensing version (*)
• Condensation pressure control switch ON-OFF compressor housing • Electronic expansion valve (*)
• Electric panel conforming to EC (Directive 2006/95/EC • Version for production of glycol water mixture at low
and Directive EMC 2004/108/EC) with anti-condensation temperatures down to - 10 °C (ARAC) (*) on request
heater (*), auxiliary circuit, general cut-off switch, • Partial / total condensation heat recovery
magneto-thermal protection cutoff switches • Integrated hydronic system with 1 or 2 pumps (1 + 1 Options
• Sequence phase control standby), expansion vessel, safety valves, water tank Units can be supplied with the following construction
• Microprocessor control system UPC1m including: • Water tank equipped with pump for primary circuit options:
- local user terminal mP20 II visible on unit with panel management • Remote user terminal mP20 II (up to 200 metres) for:

© 2012 Schneider Electric. All rights reserved.


- outlet chilled water temperature regulation • High and low pressure gauges - entering of commands
- advanced management of compressors run through • Power phase correction capacitors (compressors + fans - display unit status and alarms
automatic set-point sensitivity regulation + pumpgroup) • Spring anti-vibration kit
- compressor rotation with FIFO system (run time, • Anti-freeze protection on evaporator, water tank and • Rubber anti-vibration kit
protection and function) pump group
- pump rotation on a time basis (settable) for equal • Condensing coils equipped with safety grilles and filter
operation and start-up of the stand-by pump (with • Discharge interception valves on compressor
alarm signal) in the event of a breakdown • Sound-proofing of compressor housing
- advanced anti-freeze protection on evaporator (*) • Clock card
• RS485 serial adapter used to communicate with Uniflair

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ARAC-ARAH 06/12
Air-cooled water chillers with axial fans for outdoor installation 18 BREC 19

Uniflair BREC

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 400 ÷ 1200 kW BREC Model 1602A 1802A 2202A 2502A 2802A 3212A 3612A 4212A 481 2A
12/7°C; external temperature
Power Supply V/ph/Hz 400 / 3 / 50
Available versions 35°C; glycol 0%; refrigerant
Compressors/circuits nr x mod 2 x double screw R134a
- low noise Evaporator nr x mod 1 x Shell & Tube
2. Data refer to unit equipped
- ultra low noise Fans nr 6 6 8 8 8 10 10 12 12
with economizer at nominal
Refrigerant R-134a Unit without economizer conditions: water temperature
Double screw compressors Cooling capacity (1) kW 365 458 519 547 666 724 840 945 1077 12/7°C; external temperature
Absorbed power (1) kW 107,7 140,7 155,4 167,5 204,0 222,8 260,9 289,0 326,4 35°C; glycol 0%; refrigerant
E.E.R. 3,39 3,25 3,34 3,27 3,23 3,25 3,22 3,27 3,3 R134a
ETL certified data E.S.E.E.R. 4,11 4,24 4,19 4,21 4,29 4,48 4,77 4,37 4,64 3. Measured in free field
I.P.L.V. 4,68 4,83 4,78 4,82 4,94 5,20 5,50 5,00 5,35 conditions 10 m from the unit,
Unit with economizer coil side (Q = 2)

Cooling capacity (2) kW 392 495 560 592 721 793 909 1020,9 1163
Absorbed power (2) kW 119,2 158,4 173,1 188,4 237,0 258,4 294,7 322,6 362,5
E.E.R. 3,92 3,13 3,23 3,14 3,05 3,07 3,09 3,16 3,21
E.S.E.E.R 4,23 4,31 4,28 4,26 4,38 4,60 4,72 4,40 4,59
Standard Features - Refrigerant charge monitoring I.P.L.V. 4,78 4,91 4,85 4,89 5,00 5,20 5,55 5,05 5,40
• Self-supporting frame in galvanized steel with panels - Monitoring of the absorbed current and checking of Noise pressure levels
finished in epoxy powders (colour RAL7037) possible malfunctions Low noise version (3) 61,0 61,1 61,2 60,1 60,9 62,4 62,6 63,1 63,6
• Two semi-hermetic double screw compressors with - Advanced anti-freeze protection on evaporator Ultra low noise version (3) 55,0 55,2 55,6 54,8 55,0 57,5 57,6 58,0 58,4
internal thermal protection, discharge shut-off valve, oil - Integrated LAN card for local network connection of a Dimensions
heaters and antivibration supports group of chillers Height mm 2525 2525 2525 2525 2525 2525 2525 2525 2525
• Two refrigerant circuits conforming to EC norms (PED - Integrated clock card Length mm 4931 4931 6357 6357 6357 8890 8890 10320 10320
97/23/EC) in copper tubes including: filter dryer, flow - Rotation of pump group setting functioning and start of Width mm 2200 2200 2200 2200 2200 2200 2200 2200 2200
indicator, electronic expansion valve managed by the pump in stand-by in the event of pump breakdown
Uniflair control system, valve on the liquid line, pressure • Microprocessor control system in addition allows:
switches, transducers and manometers of high and low - Management of double set-point from remote control
pressure - Limiting of absorbed current on pre-set value or external
• High efficiency shell & tube single passage evaporator. signal
The heat exchanger is insulated with UV-resistant closed- - Rapid “Quick Start” procedure to reach total cooling
cell expanded neoprene capacity within 3 minutes
• Air side exchange coils with aluminium fins and internally - Free-contact for general alarm and 2 for addressable
grooved copper tubes alarms
• Water flow differential pressure switch - Remote ON-OFF switch
• Acousti-composite fans: Sickle-blade axial fans, - Ability to interface with Modbus protocol directly on Construction Options • Coil manifolds protection panels
statically and dynamically balanced, made from RS485 serial card • Double power supply with automatic integrated • Condensing coil cataphoresis or pre-painting treatment (*)
composite materials for high efficiency and low acoustic - Ability to interface with main external communication management on the active line
impact, with safety protection grilles protocols: Bacnet, Lonworks, Trend, Metasys, TCP/IP • Fans with electronic commutation motors (EC) (*) on request
• Modulating condensation control with fan speed and SNMP • Power phase correction capacitors
regulation • Economizer (increase in both capacity and E.E.R.) Options
• Electrical panel conforming to EC Norms (Directive • Operation possible with external temperature upto 50°C The units can be supplied with the following external
2006/95/EC and EMC 2004/108/EC, IP54) with general at full load accessories:
cut-off switch, electic bars distribution for power supply, • Low external temperature: unit works down to -20°C • Remote user terminal mP20 II (up to 200 metres with
acquisition of absorbed current, maximum internal • Ultra-low noise version with sound-proof casing and shielded cable) for:
temperature control, magnetothermal cut-off switch on mufflers for the compressors - Entering of commands
the fans and auxiliaries, fuses for the compressors • Production of glycol water mixture at low temperatures - Display unit status of alarms
• Sequence phase, minimum and maximum power supply (down to -10°C) • Spring anti-vibration kit

© 2012 Schneider Electric. All rights reserved.


monitoring • Partial condensation heat recovery • Flanged type hydraulic connection
• Microprocessor control system UPC1m including: • Suction shut-off valves on compressor • RS485 serial adaptor used to communicate with the
- Local user terminal with external accessibility • Integrated hydronic system with 1 or 2 circulation Uniflair supervisory system or to interface with external BMS
- Outlet chilled water temperature regulation by means of pumps (1 + 1 stand-by) • LON F T T10 serial adaptor used to communicate with
an exclusive PID algorithm • Integrated hydronic system with 1 or 2 inveter-driven external BMS managed with LON protocol
- Electronic expansion valve managed by the control circulation pumps (1+1 stand-by) (*) • TCP/IP serial adaptor used to communicate with
system • Anti-freeze protection on evaporator and pump group external BMS managed with SNMP protocol
- Advanced control of cooling capacity by automatic set- • Condensing coils equipped with metal safety grilles and
point sensitivity regulation filters

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BREC 06/12
Air-cooled modulating water chillers with axial fans for outdoor installation 20 BCEC 21

Uniflair BCEC

Technical Data 1. Data refer to nominal


Range
conditions: Inlet / outlet water
BCEC Model 0301A 0401A 0532A 0632A 0752A 0903A 1103A
Cooling capacity: 400 ÷ 1100 kW Power Supply V/ph/Hz 400/3/50
temperature: 12 / 7 °C; External
air temperature 35 °C; glycol
Available versions Compressor/s nr x model 1 x oil free 2 x oil free 3 x oil free 0%
Cooling circuits nr 1
- low noise 2. Data refer to total input
Evaporator nr x model 1 x flooded
power.(compressors and fans)
Refrigerant R-134a Fans nr x model 6 6 8 10 12 14 16
“oil-free” centrifugal compressors 3. European Seasonal Energy
Unit with asynchronous motor fans (AC)
Efficiency Ratio
with magnetic bearings Cooling capacity (1) kW 296 391 530 605 750 875 1100
Absorbed power (2) kW 91,6 120,1 158,8 181,3 218,6 261,0 325,3 4. Integrated Partial Load
Value
E.E.R. (2) 3,23 3,25 3,34 3,34 3,43 3,35 3,38
E.S.E.E.R. (3) 5,03 4,92 5,17 5,07 5,37 5,39 5,62 5. Measured in free-field
conditions 10 mt from the unit,
I.P.L.V. (4) 5,92 5,88 5,84 5,58 6,31 6,16 6,56
coil side (Q=2)
Noise pressure level (5) dB(A) 52,1 52,5 53,5 54,0 55,0 55,0 55,5
Max. ambient temperature °C 42
Unit with electronically COMMUTED motor fans (EC)
Cooling capacity (1) kW 300 400 530 630 750 900 1100
Standard Features temperature control, absorbed current control, auxiliary Absorbed power (2) kW 92,2 121,4 155,6 188,8 213,6 265,8 308,2
• Self-supporting frame in galvanized steel with panels transformer, general auxiliary cut-off switch, fuses on the E.E.R. (2) 3,25 3,29 3,41 3,34 3,51 3,39 3,57
finished in epoxy powders (colour RAL9022) compressors and remote control cut-off switches E.S.E.E.R. (3) 5,09 4,99 5,27 5,24 5,51 5,52 5,68
• Between one to three “oil free” centrifugal compressors • Line reactance for each compressor to stabilize the I.P.L.V. (4) 6,08 5,95 5,91 5,84 6,38 6,34 6,61
with magnetic bearings equipped with: power supply Noise pressure level (5) dB(A) 52,1 52,5 53,5 54,0 55,0 55,0 55,5
- internal thermal protection • Phase sequence control and minimum / maximum Max. ambient temperature °C 45
- protection and control of the rotation axis position power supply and voltage Dimensions
- brushless synchronized DC motor • Microprocessor control system including: Height mm 2510 2510 2510 2510 2510 2510 2510
- integrated control system - continuous control of the cooling capacity by means of Length mm 5000 5000 6430 7860 9290 10720 12150
- speed control with inverter an inverter and IGV (Inlet Guide Vane) Depth mm 2200 2200 2200 2200 2200 2200 2200
- soft start start-up - local user terminal with external display
- phase sequence control - outlet chilled water temperature regulation by means of
- pre-rotation valve an exclusive PID algorithm
- temperature and pressure sensors - integrated LAN card for connecting more than one unit
- 2 centrifugal compression stages to the local area network Construction Options Options
- anti-vibration kit - acquisition and management of main electrical data • Double power supply with automatic integrated The units can be supplied with the following external
• Soundproofing enclosures for compressor/s - clock card management on the active line and integrated condenser accessories:
• Single refrigerant circuit conforming to EC standards • Microprocessor control system in addition allows: for control • Remote user terminal PDG (up to 200 meters with
(PED 97/23/ CE) with copper tubing including: filter dryer, - USB card for easy download of the operating • Separate power supply for quick start procedure shielded cable) for:
liquid sight glass, electronic expansion valve controlled parameters • Double power supply with automatic integrated - entering of commands
by a level sensor, discharge and suction taps on the - management of double set-point from remote control management on the active line and additional separate - display unit status of alarms
compressor, pressure switches, high and low pressure - free-contact for general alarm and 2 for addressable power supply for quick start procedure • Spring anti-vibration kit
transducers and gauges alarms • Power meter for a continuous measurement of the unit • Flanged type hydraulic connection
• By-pass line for vacuum start-up with high pressure - remote ON-OFF switch power consumption and communication to the BMS • Additional RS485 serial adaptor used to communicate
ratio - integrated RS485 serial card for direct connection to • Acoustic-composite fans with electronic commutation with the Uniflair supervisory system or to interface with
• Flooded evaporator featuring an integrated de-mister external BMS motors (EC) external BMSs
to prevent the formation of droplets: the exchanger is - direct interface with serial BMSs with Modbus protocol • Low external temperature option: unit can operate down • LON FTT10 serial adaptor used to communicate with
insulated with closed-cell expanded polyurethane - interface with main BMS protocols, such as Bacnet, to -20°C external temperature external BMSs managed with LON protocol
• Air side exchange coil with aluminium fins and internally Lonworks, Trend, Metasys, SNMP/TCP-IP and KNX • Integrated hydronic system with 1 or 2 circulation • TCP/IP serial adaptor used to communicate with
grooved copper tubes pumps external BMSs managed with SNMP protocol
• Differential water pressure switch • Integrated hydronic system with 1 or 2 inverter-driven • Lifting kit

© 2012 Schneider Electric. All rights reserved.


• Acoustic-composite fans: Sickle-blade axial fans, circulation pumps and pressure transducers (1 + 1 stand-by)
statically and dynamically balanced, made from • Anti-freeze protection on evaporator and pump/s group
composite materials for high efficiency and low acoustic • Condensing coils equipped with metal safety grilles and
impact, with safety protection grilles filters
• Modulating condensation control with continuous • Coil manifolds protection panels
regulation of the fans speed • Condensing coil cataphoresis or pre-painting treatment (*)
• Electric panel conforming to EC standards (2006/95/EC
and EMC 2004/108/EC directives) with EMC integrated (*) on request
filter for protection of the harmonics, maximum internal

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BCEC 06/12
Air-cooled water chillers with axial fans and free-cooling system 22 ERAF 23

Uniflair ERAF

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 50 ÷ 120 kW ERAF MODEL 0521A 0621A 0721A 0821A 0921A 0922A 1021A 1022A 1221A 1222A
10/15°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 20%; R410A
Fans nr. 2 2 2 3 3 3 3 3 4 4 refrigerant
- low noise Refrigerant circuits nr. 1 1 1 1 1 2 1 2 1 2
2. Data refer to the total
- ultra low noise Compressors nr. x mod 2 x Scroll
absorbed power (compressors
Evaporator nr. 1 1 1 1 1 2 1 2 1 2
Refrigerant R-410A and fans)
Scroll Compressors Evaporator mod Plate
3. Data refer to nominal
ERAF - Low noise version
conditions: inlet water
Cooling capacity (1) kW 50 59 69 80 88 88 102 102 117 118 temperature 15°C; external
Absorbed power (1)(2) kW 14,7 18,8 20,7 23,3 27,7 27,7 31,8 31,8 37,4 37,5 temperature 5°C; glycol 20%
E.E.R. (2) 3,40 3,13 3,35 3,43 3,17 3,17 3,20 3,20 3,14 3,14
4. Data refer to the absorbed
Capacity in free-cooling (3) kW 35 37 43 52 53 53 62 62 71 71 power of the fans and the free-
- Anti-freeze protection E.E.R. (3)(4) 22,40 23,50 21,30 18,98 18,98 19,53 25,58 25,58 22,80 22,84 cooling pump
- Compressor timing and protection Noise pressure level (5) dB(A) 42,6 43,5 44,0 44,3 44,3 44,3 53,4 53,4 54,7 54,7 5. Data measured in free
- Compressor rotation based on FIFO logic ERAF - Ultra low noise version field at 10 metres from the
- Pump rotation on a timed basis for equal operation and Cooling capacity (1) kW 48 56 67 77 84 84 97 97 112 113 unit operating at nominal
Standard Features startup of the stand-by pump (with alarm signal) in the Absorbed power (1)(2) kW 15,2 19,8 22,0 24,4 29,3 29,3 33,8 33,9 39,6 39,7 conditions, coil side, Q=2
• E xclusive free-cooling system completely managed by event of a breakdown E.E.R. (2) 3,18 2,85 3,04 3,16 2,87 2,87 2,87 2,88 2,83 2,85 directional factor
the microprocessor control - Display of compressor operating hours Capacity in free-cooling (3) kW 31 32 38 46 47 47 54 54 63 63 6. Data refer to an empty unit
• Self supporting frame in galvanised steel with panels - Alarm code signal E.E.R. (3)(4) 24,29 25,29 20,51 20,02 20,51 20,51 25,91 25,91 24,63 24,29 without pump and water tank
varnished with epoxy powders (colour RAL7037) - General alarm with clean signal contact Noise pressure level (5) dB(A) 39,1 39,8 40,3 40,1 40,1 40,1 49,6 49,6 51 51
• Access panel to the unit equipped with handles and fast - ON-OFF remote control Dimensions and weights
screws Height mm 1560 1560 1560 1560 1560 1560 1875 1875 1875 1875
• Two hermetic scroll compressors with internal thermal Depth mm 1190 1190 1190 1190 1190 1190 1190 1190 1190 1190
protection, anti-vibration supports and crankcase heaters Width mm 2010 2010 2805 2805 2805 2805 3075 3075 3075 3075
• Single refrigerant circuit (*) conforming to EC Directives Weight (6) kg 700 705 855 884 890 881 1128 1107 1157 1137
(PED 97/23/CE) in copper tubing including filter dryer, Total Operating Performance
liquid sight glass, dual flow thermostatic valve with • Electronic expansion valve directly controlled by the
external equalisation, high and low pressure switches and unit microprocessor control
high pressure transducers • Evolved UpCO1m control for:
• Environmentally friendly R410A Refrigerant - Discharge water temperature regulation
• Water side brazed plate heat exchanger in stainless - Management of the electronic thermostatic valve
steel insulated with closed cell expanded polyurethane - Management of Intelligent free-cooling
• Free-cooling air side exchange coil with aluminium fins - Monitoring of the refrigerant load
and mechanically-expanded copper tubes - Self-adjustment of the set-point regulation
• Free-cooling pump driven by microprocessor control - Integrated LAN card
• Water flow differential pressure switch - Compatibility with the most common external BMS
• Acousti-composite fans: Sickle-blade axial fans, systems and with the Modbus protocol using only a
RS485 card Construction Options Options
statically and dynamically balanced and made from
• Ultra low noise version via a specific algorithm and • Remote user terminal mP20 II (up to 200 metres) for:
composite materials for high efficiency and low acoustic
soundproofing of the compressors - entering of commands
impact with internal and external safety protection grilles
• Partial condensation heat recovery - display unit status and alarms
(motor with IP54 protection grade) (*)ERAF models with **22A suffix are available with two • Integrated hydraulic module with one or two pumps (1 • Clock card
• Modulating condensation control based on the compressors on two circuits + 1 stand-by) with heat-protected circulation, expansion • RS485 serial card, FTT10 or TCP/IP for connection to
condensation pressure
vessel and safety valve the Uniflair supervision system or an external BMS
• Electrical panel conforming to EC Directives
• Internal water tank • Metal filters and protection grilles for the condensing
(2006/95/EC and EMC 2004/108/EC) protection grade
• Internal water tank including a pump to manage the coils
IP54 with auxiliary transformer, lockable general cut off

© 2012 Schneider Electric. All rights reserved.


primary circuit • Rubber or spring anti-vibration supports
switch, anti-condensation heaters, automatic magneto-
• Power factor improvement compressors
thermal cut off switches and remote control
• Compressor Softstart
• Sequence phase control
• Cataphoresis treatment for the condensing coils
• Microprocessor control system including:
• Shut off taps on the compressor discharge
- Local user terminal externally visible and accessible via
• Evaporator, water tank and pump group anti-freeze
an access hatch
heaters
- Chilled/hot water temperature regulation (ERAH) on the
• Modification of the set point by external 0-10V signal
discharge

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ERAF 06/12
Air-cooled modulating water chillers with axial fans and free-cooling system 24 ISAF 25

Uniflair ISAF

Range Technical Data 1. Data refer to nominal


conditions: water temperature:
Cooling capacity: 60 ÷ 120 kW ISAF MODEL 0621A 0921A 1221A
15/10°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 20%; inverter
Fans nr. 2 3 4 compressor at 90rps R410A
- low noise Refrigerant circuits nr. 1 1 1 refrigerant
Compressors nr. 1 ON/OFF + 1 inverter driven (Scroll)
Refrigerant R-410A 2. Data refer to total input
Evaporator nr. 1 1 1
Inverter driven Scroll compressors power (compressors and fans)
Evaporator mod Plate
3. Data refer to nominal
ISAF – Low noise version
conditions: inlet water
Cooling capacity (1) kW 62,4 92,2 122,2 temperature 15°C, external
Absorbed power (1)(2) kW 20,0 28,5 38,3 temperature 5°C; glycol 20%;
Capacity in free-cooling (3) kW 38 55 73 inverter compressor at 90 rps
Absorbed power in free-cooling (3)(4) kW 1,6 2,7 3,1 4. Data refer to total absorbed
E.E.R. in free-cooling (4) 23,8 20,4 20,5 power (fans and free-cooling
Noise pressure level (5) dB(A) 43,5 44,3 54,7 pump)
Dimensions and weights 5. Data measured in free field
Height mm 1560 1560 1874 conditions at 10m from the
Standard Features aluminium fins and mechanically expanded copper piping Length mm 1190 1190 1192 unit operating in nominal
• Exclusive free-cooling system completely managed by • Acousti-composite fans: Sickle-blade axial fans, Width mm 2008 2798 3075 conditions, coil side, directional
the control system statically balanced and made from composite material factor Q=2
Weight (basic version) (6) Kg 751 935 1212
• Self-supporting galvanized sheet steel framework with ensuring elevated efficiency and low noise, with external 6. Data refer to an empty unit
panels painted with epoxy powder paints (colour RAL and internal protection grill without pump
7037) equipped with fast screws for easy and quick • Modulating condensation control by means of
access continuous fan speed control
• Inverter-driven hermetic Scroll compressor, equipped • Electrical panel in accordance with EC standards
with (directive 73/23/EC and directive EMC 89/336/EC) IP54
- Inverter speed control protection grade with auxiliary transformer, minimum and
- Oil by-pass valve and line maximum temperature control, general door interlock cut
- Soft start off switch, protection and remote control switches
- Integrated power factor correction condenser • Phase sequence control
- Integrated thermal protection • UPC1m microprocessor control including:
- Anti-vibration supports - Chilled / hot water temperature regulation by means of
• Inverter driver with IP54 protection grade coupled with self adaption of the set point regulation band
a specific compressor and positioned in a dedicated - Management of the electronic thermostatic valve
housing compartment - Compressor management driven by inverter
• Compressor sound-proofing with noise insulating - Quick start start-up procedure
jackets and, only for model 1221A, soundproofing of the - Integrated LAN card
compressor compartment - Integrated clock card
• Vibration absorbers on the compressor discharge and - Compatibility with Modbus protocol via RS485
suction line (only for model 1221A) - Compatability with the most common external BMS:
• Single refrigerant circuit in accordance with EC LONworks, BacNET, TCP/IP, Trend Construction Options Options
standards (directive PED 97/23/CE) in copper piping • Integrated hydraulic module with one or two pumps • Remote user terminal mP20 II (up to 200 metres) for:
including dehydration filter, liquid sight glass, electronic (1+1 in stand-by) with heat protected circulation, - entering of commands
expansion valve connected to and driven by the unit expansion vessel and safety valve - display unit status and alarms
control, high and low pressure switches and transducers. • Integrated hydraulic module with one or two inverter • RS485 serial adaptor used to communicate with the
The refrigerant circuit features an exclusive patented driven pumps (1+1 in stand-by) with heat protected Uniflair supervisory system or to interface with external
system for optimum lubrification management of the circulation, expansion vessel and safety valve BMS
tandem compressors • Intelligent free-cooling (only with onboard pumps) • LON F T T10 serial adaptor used to communicate with

© 2012 Schneider Electric. All rights reserved.


• Continuous operation up to -20°C • Cataphoresis treatment for condensing and free-cooling external BMS managed with LON protocol
• Environmentally friendly refrigerant R410A coils • TCP/IP serial adaptor used to communicate with
• Crankcase heaters and inverter with oil heating function • Shut-off taps on the compressor discharge external BMS managed with SNMP protocol
• Brazed plate water side heat exchangers in stainless • Power factor correction on compressors • Air side coil protection filters and grills
steel, insulated with closed-cell expanded polyurethane • Modification of the set-point by external signal 0-10V • Rubber or spring anti-vibration supports
and anti-freeze heaters • EC fans
• Pump for free-cooling circuit
• Water flow differential pressure switch
• Air side exchange coil and free-cooling coil with

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ISAF 06/12
Air-cooled water chillers with free-cooling system 26 ARAf 27

Uniflair ARAf

Range Technical Data 1. Data refer to nominal

R407C
conditions: water temperature
Cooling capacity: 130 ÷ 280 kW ARAF MODEL 0644A 0744A 0964A 1084A 1204A
10/15°C; external temperature
Power supply V/ph/Hz 400 / 3 / 50
Available versions 35°C; glycol 20%; R407C
Circuits / compressors nr. 2/4 2/4 2/4 2/4 2/4 refrigerant
- standard with modulating condensation control Fans nr. 2 3 3 4 4
2. With pump group
- low noise Condensing coil/free-cooling coil nr. 1+1/1+1
Evaporator nr. x mod 1 x Shell & Tube 3. Measured in free field
Refrigerant R-407C conditions, coil side, direction
Scroll Compressors Basic version
factor Q=2, at 10 mt. from the
Cooling capacity (1) kW 144 177 203 245 276
unit (at nominal conditions)
Absorbed power (1) kW 52 57 78 90 103
4. Data refer to nominal
Cooling capacity in free-cooling (4) kW 85 146 152 196 202
conditions: inlet water
Absorbed power in free-cooling (4) kW 6,3 8,4 7,9 9,9 10,0
temperature 15°C; external
Noise pressure level (3) dB(A) 47 48 48 50 50 temperature 5°C; glycol 20%
Low noise version
5. Data refer to nominal
Cooling capacity (1) kW 133 167 188 228 252 conditions: recovery water
Absorbed power (1) kW 58 62 86 98 114 temperature 40/45°C; chilled
Cooling capacity in free-cooling (4) kW 70 123 127 163 166 water temperature 10/15°C;
Standard Features - advanced anti-freeze protection on evaporator Absorbed power in free-cooling (4) kW 5,1 6,5 6,0 7,4 7,6 external temperature 35°C;
• Exclusive free-cooling Uniflair system completely - integrated LAN card for local network connection of a Noise pressure level (3) dB(A) 47 48 48 50 50 glycol 20%; R407C refrigerant
managed by the microprocessor control group of chillers (up to 10 units with 1or 2 units in Partial heat recovery (option) 6. Data refer to empty unit
• Self-supporting frame in galvanised steel (colour stand-by) Exchanger type nr. plate / 2
RAL7037) with panels varnished with epoxy powders • Moreover, the microprocessor control system permits: Thermal heat recovery (5) kW 48 53 75 76 86
• Modulating condensation control with automatic - an overlapped management of units as a single chiller Water flow l/h 8256 9116 12900 13072 14792
regulation of fans speed (up to 10) Dimensions and weight
• Four hermetic Scroll compressors with incorporated - management of double set-point and selection Height mm 1618 2140 2140 2140 2140
thermal protection, with anti-vibration supports and - free-contact for general alarm and 2 addressable alarms Depth mm 3807 4542 4542 5242 5242
crankcase heaters management Width mm 1193 1344 1344 1344 1344
• Shell & tube evaporator insulated with closed-cell - remote ON-OFF switch Weight (only with free-cooling pump) (6) Kg 1451 2164 2411 2682 2790
expanded neoprene - ability to interface with Modbus protocol directly on Weight (water tank, 2 + f.c. pump) (6) Kg 1734 2468 2731 3037 3148
• Condensing and free-cooling coils with aluminium fins RS485 serial card
and mechanically expanded copper tubes - ability to interface with main external communication
• Condensing coil protection filters and grilles protocols: Bacnet, Lonworks, Metasys, TCP/IP and
• Axial fans, statically and dynamically balanced, with SNMP
sickleblades and with safety protection grilles
• Two independent refrigerant circuits conforming to
EC norms (PED 97/23/EC directive) in copper tubing
including: filter dryer, flow indicator, thermostatic valves
with external equalization, high & low pressure switches
and high pressure transducers
• Free-cooling pump regulated by microprocessor control
• Electric panel conforming to EC norms (2006/95/EC Construction Options • Electronic expansion valve (*)
directive and EMC 2004/108/EC directive) complete with • Low noise version with modulating condensation control • Intelligent free-cooling (*)
anti-condensation heater, auxiliary circuit, general cut-off through special algorithm and sound-proofing of
switch, magneto-thermal protection cut-off switches for compressor housing (*) on request
compressors, fans and auxiliaries • Partial condensation heat recovery
• Sequence phase control • Integrated hydronic system with 1 or 2 pumps (1 + 1 Options
• Water flow differential pressure switch stand-by), expansion vessel, safety valve, water tank Units can be supplied with the following construction
• Microprocessor control system UPC1m including: • High and low pressure gauges options:

© 2012 Schneider Electric. All rights reserved.


- local user terminal mP20 II visible on unit with panel • Power phase correction capacitors (compressors + fans • Remote user terminal mP20 II (up to 200 meters with
- outlet chilled water temperature regulation + pump group) shielded cable) for:
- advanced management of compressors run through • Discharge interception valves on compressor - entering of commands
automatic set-point sensitivity regulation • Sound-proofing of compressor housing - display unit status and alarms
- compressor rotation with FIFO system (run time, • Clock card • Spring anti-vibration kit
protection and function) • RS485 serial adapter used to communicate with Uniflair • Rubber anti-vibration kit
- Pump rotation on a time basis (settable) for equal supervision system or to interface with external BMS
operation and start-up of the stand-by pump (with alarm • Condensing coil cataphoresis treatment
signal) in the event of a breakdown • R134a Refrigerant (*)

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ARAF 06/12
Air-cooled water chillers with axial fans and free-cooling system 28 BREF 29

Uniflair BREF

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 400 ÷ 1200 kW BREF MODEL 1602A 1802A 2202A 2502A 2802A 3212A 3612A 4212A 4812A
15/10°C; external temperature
Power supply V/ph/Hz 400 / 3 / 50
Available versions 35°C; glycol 20%; refrigerant
Compressors / circuits nr. x mod 2 x double screw R134a
- Low noise Evaporator nr. x mod 1 x Shell &Tube
2. Data refer to unit equipped
- Ultra-low noise Fans nr. 6 6 8 8 8 10 10 12 12
with economizer in nominal
Unit without economizer
Refrigerant R-134a conditions: water temperature
Double screw compressors Cooling capacity (1) kW 400 481 557 590 696 782 883 1000 1143 15/10°C; external temperature
Absorbed power (1) kW 115,0 150,0 165,3 178,0 218,0 235,5 278 308 350,5 35°C; glycol 20%; refrigerant
E.E.R. (1) 3,47 3,20 3,37 3,31 3,19 3,32 3,17 3,25 3,26 R134a
ETL certified data Cooling capacity 3. Data refer to nominal
kW 256 308 347 351 417 510 602 711 726
in free-cooling (3) conditions: inlet water
Absorbed power temperature 15°C; external
kW 16,7 17,6 23,9 24,1 25,4 28,5 29,4 38,2 38,6 temperature 5°C; glycol 20%
in free-cooling (3)
E.E.R. in free-cooling (3) 15,34 17,52 14,50 14,53 16,43 17,9 20,5 18,6 18,8 4. Measured in free field
Unit with economizer conditions 10 m from the unit,
Cooling capacity (2) kW 416 517 590 628 764 859 957 1085 1231,5 coil side (Q = 2)

Standard Features - local user terminal with external accessibility Absorbed power (2) kW 124,0 165,5 184,0 197,0 251,0 275 315 350 400
• Exclusive Uniflair free-cooling system completely - outlet chilled water temperature regulation by means of E.E.R. (2) 3,35 3,12 3,21 3,19 3,04 3,12 3,04 3,1 3,08
managed by the microprocessor control an exclusive PID algorithm Cooling capacity
kW 260 312 352 356 423 510 602 711 726
• Self-supporting frame in galvanized steel with panels - electronic expansion valve managed by the control in free-cooling (3)
finished in epoxy powders (colour RAL7037) system Absorbed power
kW 16,9 17,7 24,2 24,5 25,8 28,5 29,4 38,2 38,6
• Two semi-hermetic double screw compressors with - advanced control of cooling capacity by automatic set- in free-cooling (3)
internal thermal protection, discharge shut-off valve, oil point sensitivity regulation E.E.R. in free-cooling (3) 15,42 17,63 14,54 14,56 16,44 17,9 20,5 18,6 18,8
heaters and antivibration supports - refrigerant charge monitoring Noise pressure levels
• Two refrigerant circuits conforming to EC norms (PED - monitoring of the absorbed current and checking of Low noise version (4) dB(A) 61,0 61,1 61,2 60,1 60,9 62,4 62,6 63,1 63,6
97/23/EC) in copper tubes including: filter dryer, flow possible malfunctions Ultra low noise version (4) dB(A) 55,0 55,2 55,6 54,8 55,0 57,5 57,6 58,0 58,4
indicator, electronic expansion valve managed by the - advanced anti-freeze protection on evaporator Dimensions
control system, electrovalve on the liquid line, pressure - integrated LAN card for local network connection of a Height mm 2525 2525 2525 2525 2525 2525 2525 2525 2525
switches, transducers and manometers of high and low group of chillers Length mm 4931 4931 6357 6357 6357 8890 8890 10320 10320
pressure - integrated clock card Width mm 2200 2200 2200 2200 2200 2200 2200 2200 2200
• Possibility of operation with external temperatures down - rotation of pump group setting functioning and start of
to -25°C pump in stand-by in the event of pump breakdown
• High efficiency shell & tube single passage evaporator. • Microprocessor control system in addition allows:
Construction Options • Condensing and free-cooling coil cataphoresis or
The heat exchanger is insulated with UV-resistant closed- - management of double set-point from remote control
• Double power supply with automatic integrated prepainting treatment (*)
cell expanded neoprene - limiting of absorbed current on pre-set value or external
management on the active line
• Air side exchange coils with aluminium fins and internally signal
• Fans with electronic commutation motors (EC) (*) on request
grooved copper tubes - rapid “Quick Start” procedure to reach total cooling
• Power phase correction capacitors
• Water flow differential pressure switch capacity within 3 minutes
• Economizer (permits an increase in both capacity and Options
• Acousti-composite fans: Sickle-blade axial fans, - free-contact for general alarm and 2 for addressable
E.E.R.) The units can be supplied with the following external
statically and dynamically balanced, made from alarms
• Operation possible with external temperature up to accessories:
composite materials for high efficiency and low acoustic - remote ON-OFF switch
50°C at full load • Remote user terminal mP20 II (up to 200 metres with
impact, with safety protection grilles - ability to interface with Modbus protocol directly on
• Ultra-low noise version with sound-proof casing and shielded cable) for:
• Modulating condensation control with fan speed RS485 serial card
mufflers for the compressors - entering of commands
regulation - ability to interface with main external communication
• Intelligent Free-cooling for an increase in efficiency with - display unit status of alarms
• Electrical panel conforming to EC Norms (Directive protocols: Bacnet, Lonworks, Trend, Metasys, TCP/IP
unit in stand-by • Spring anti-vibration kit
2006/95/EC and EMC 2004/108/EC, IP54) with general and SNMP
• Glycol-free version • Flanged type hydraulic connection
cut-off switch, power supply electic bars distribution,

© 2012 Schneider Electric. All rights reserved.


• Partial condensation heat recovery • RS485 serial adaptor used to communicate with the
acquisition of absorbed current, minimum and maximum
• Suction shut-off valves on compressor Uniflair supervisory system or to interface with external
internal temperature control, magnetothermal cut-off
• Integrated hydronic system with 1 or 2 circulation BMS
switch on the fans and auxiliaries, fuses for the
pumps (1+1 stand-by) • LON F T T10 serial adaptor used to communicate with
compressors
• Integrated hydronic system with 1 or 2 inveter-driven external BMS managed with LON protocol
• Sequence phase, minimum and maximum power supply
circulation pumps (1+1 stand-by) (*) • TCP/IP serial adaptor used to communicate with
monitoring
• Condensing and free-cooling coils equipped with metal external BMS managed with SNMP protocol
• Free-cooling pump regulated by microprocessor control
safety grilles and filters
• Microprocessor control system UPC1m including:
• Coil manifolds protection panels

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BREF 06/12
Air-cooled modulating water chillers with axial fans and free-cooling system 30 BCEF 31

Uniflair BCEF

Technical Data 1. Data refer to nominal


Range
conditions: water temperature
BCEF Model 0301A 0401A 0532A 0632A 0752A 0903A 1103A
Cooling capacity: 400 ÷ 1100 kW Power Supply V/ph/Hz 400/3/50
10/15°C; external temperature
35°C; glycol 20%; refrigerant
Available versions Compressor/s nr x model 1 x oil free 2 x oil free 3 x oil free R134a
Cooling circuits nr 1
- low noise 2. Data refer to nominal
Evaporator nr x model 1 x flooded
conditions: inlet water
Refrigerant R-134a Fans nr x model 6 6 8 10 12 14 16 temperature 15°C; external
“oil-free” centrifugal compressors Unit with asynchronous motor fans (AC) temperature 5°C; glycol 20%;
with magnetic bearings Cooling capacity (1) kW 310 411 550 637 800 917 1213 refrigerant R134a
Absorbed power (2) kW 89,4 121,0 158,1 177,1 228,3 266,0 359,9 3. Measured in free field
E.E.R. (2) 3,47 3,40 3,48 3,60 3,50 3,45 3,37 conditions 10 m from the unit,
Free-cooling capacity (3) kW 246 296 395 427 587 682 783 coil side (Q = 2)
Absorbed power kW 16,0 17,1 24,4 28,2 32,6 41,3 45,8
in free-cooling (3)(4)
E.E.R. in free-cooling (3)(4) 15,37 17,27 16,18 15,16 18,01 16,51 17,08
Noise pressure level (5) dB(A) 52,1 52,5 53,5 54,0 55,0 55,0 55,5
Max. ambient temperature °C 40
Standard Features /95 /EC and EMC 2004/108/EC directives) with EMC Unit with electronically commutated motor fans (EC)
• Exclusive Uniflair free-cooling system completely integrated filter for protection of the harmonics, maximum Cooling capacity (1) kW 310 411 550 637 800 917 1213
managed by the microprocessor control internal temperature control, absorbed current control Absorbed power (2) kW 89,2 120,9 157,9 176,8 222,3 260,2 351,3
• Self-supporting frame in galvanized steel with panels auxiliary transformer, general auxiliary cut-off switch, fuses E.E.R. (2) 3,47 3,40 3,48 3,60 3,60 3,52 3,45
finished in epoxy powders (colour RAL9022) on the compressors and remote control cut-off switches Free-cooling capacity (3) kW 273 339 452 482 672 779 905
• Between one to three “oil free” centrifugal compressors • Line reactance for each compressor to stabilize the Absorbed power kW 19,8 21,3 30,0 34,9 41,0 51,1 57,4
with magnetic bearings equipped with: power supply in free-cooling (3)(4)
- internal thermal protection • Phase sequence control and minimum / maximum E.E.R. in free-cooling (3)(4) 13,74 15,90 15,09 13,83 16,39 15,26 15,76
- protection and control of the rotation axis position power supply and voltage Noise pressure level (5) dB(A) 52,1 52,5 53,5 54,0 55,0 55,0 55,5
- brushless synchronized DC motor • Free-cooling pump regulated by microprocessor control Max. ambient temperature °C 43
- integrated control system • Microprocessor control system including: Dimensions
- speed control with inverter - continuous control of the cooling capacity by means of Height mm 2510 2510 2510 2510 2510 2510 2510
- soft start start-up an inverter and IGV (Inlet Guide Vane) Length mm 5000 5000 6430 7860 9290 10720 12150
- phase sequence control - local user terminal with external display Depth mm 2200 2200 2200 2200 2200 2200 2200
- pre-rotation valve - outlet chilled water temperature regulation by means of
- temperature and pressure sensors an exclusive PID algorithm
- 2 centrifugal compression stages - integrated LAN card for connecting more than one unit
- anti-vibration kit to the local area network Construction Options Options
• Soundproofing enclosures for compressor/s - acquisition and management of main electrical data • Double power supply with automatic integrated The units can be supplied with the following external
• Single refrigerant circuit conforming to EC standards - clock card management on the active line accessories:
(PED 97/23/ CE) with copper tubing including: filter dryer, • Microprocessor control system in addition allows: • Separate power supply for quick start procedure • Remote user terminal PDG (up to 200 meters with
liquid sight glass, electronic expansion valve controlled - USB card for easy download of the operating • Double power supply with automatic integrated shielded cable) for:
by a level sensor, discharge and suction taps on the parameters management on the active line and additional separate - entering of commands
compressor, pressure switches, high and low pressure - management of double set-point from remote control power supply for quick start procedure - display unit status of alarms
transducers and gauges - free-contact for general alarm and 2 for addressable • Power meter for a continuous measurement of the unit • Spring anti-vibration kit
• By-pass line for vacuum start-up with high pressure alarms power consumption and communication to the BMS • Flanged type hydraulic connection
ratio - remote ON-OFF switch • Acoustic-composite fans with electronic commutation • Additional RS485 serial adaptor used to communicate
• Flooded evaporator featuring an integrated de-mister - integrated RS485 serial card for direct connection to motors (EC) with the Uniflair supervisory system or to interface with
to prevent the formation of droplets: the exchanger is external BMS • Intelligent free-cooling external BMSs
insulated with closed-cell expanded polyurethane - direct interface with serial BMSs with Modbus protocol • Glycol free arrangement (*) • LON FTT10 serial adaptor used to communicate with
• Differential water pressure switch - interface with main BMS protocols, such as Bacnet, • Integrated hydronic system with 1 or 2 circulation external BMSs managed with LON protocol

© 2012 Schneider Electric. All rights reserved.


• Air side exchange coil with aluminum fins and internally Lonworks, Trend, Metasys, SNMP/TCP-IP and KNX pumps (1 + 1 stand-by) • TCP/IP serial adaptor used to communicate with
grooved copper tubes • Integrated hydronic system with 1 or 2 Inverter-driven external BMSs managed with SNMP protocol
• Acoustic-composite fans: Sickle-blade axial fans, circulation pumps and pressure transducers (1 + 1 stand-by) • Lifting kit
statically and dynamically balanced, made from • Coils equipped with metal safety grilles and filters
composite materials for high efficiency and low acoustic • Coil manifolds protection panels
impact, with safety protection grilles • Condensing coil cataphoresis or pre-painting treatment (*)
• Modulating condensation control with continuous
regulation of the fans speed (*) on request
• Electric panel conforming to EC standards (2006

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BCEF 06/12
Water cooled water chiller and heat pump 32 BRWC - BRWH 33

Uniflair BRWC - BRWH

Range Technical Data 1. Data refer to nominal


conditions: Evaporator in/
Cooling capacity: 300 ÷ 1200 kW BRWC/BRWH
1402A 1602A 1802A 2002A 2202A 2502A 2802A 3202A 3602A 4202A 4802A out water temperature:
Heating capacity: 370÷ 1370 kW MODELS
12/7°C; Condenser in/out
Power Supply V/ph/Hz 400 / 3 / 50
Available versions water temperature: 30/35°C;
Compressors nr x mod 2 x Semi-hermetic double screw condenser fouling coefficient:
- basic Evaporator nr x mod 1 x Shell & Tube 0,000043 m²°C/W; evaporator
- sea water condersers Condensers nr x mod 2 x Shell & Tube fouling coefficient: 0,000043
- high condensing water temperature (**) Cooling only (BRWC) m²°C/W; R134a refrigerant

Cooling capacity (1) kW 330 389 430 476 544 631 712 830 954 1077 1204 2. Data refer to nominal
Refrigerant R-134a
Absorbed power (1) kW 71,8 82,2 96,9 100,2 116,6 131,5 146,0 172,8 196,3 225,9 249,0 conditions: Evaporator in/
Double screw compressors
I.P.L.V. (3) 5,10 5,52 5,00 5,52 5,88 5,50 5,68 5,63 6,03 5,50 5,63 out water temperature:
12/7°C; Condenser in/out
E.S.E.E.R (4) 4,78 5,11 4,67 5,11 5,35 5,08 5,26 5,15 5,45 5,03 5,20
water temperature: 40/45°C;
Heat pump (BRWH)
condenser fouling coefficient:
Heating capacity (2) kW 377 440 494 541 627 715 806 938 1091 1216 1368 0,000043 m²°C/W; evaporator
Noise levels fouling coefficient: 0,000043
Noise pressure level m²°C/W; R134a refrigerant
73,5 73,7 73,8 78,0 79,5 79,7 79,6 77,3 75,3 76,3 78,4
basic version (5) 3. Integrated Partial Load
Standard Features - double set-point management with contact selection Noise pressure level Value: based on ARI conditions
64,0 63,9 64,6 68,5 69,6 68,7 72,4 69,3 69,1 71,8 72,5
• Self-supporting frame in galvanised steel with panels - general alarm contact and 2 addressable alarms LN version (5)
4. European Seasonal Energy
finished in epoxy powders (colour RAL7037) - ON-OFF remote control Dimensions
Efficiency Ratio
• Two semi-hermetic double screw compressors with - ability to interface with Modbus protocol directly on Height mm 2050 2050 2050 2050 2050 2060 2060 2295 2295 2295 2295
5. Measured in free field with
internal thermal protection, oil heaters and anti-vibration RS485 serial card Length mm 3660 3660 3660 3800 3800 4070 4070 4130 4130 4130 4130
Q=2 directionality factor, at a
supports - ability to interface with main external communication Depth mm 860 860 860 860 860 860 860 1485 1485 1485 1485 distance of 1 mt. from the unit
• Two refrigerant circuits conforming to EC standards protocols: Bacnet, Lonworks, Metasys, TCP/IP and Width with heat
mm 1680 1680 1680 1680 1680 1755 1755 1660 1660 1660 1660 6. Data refer to basic versions
(PED 97/23/CE) in copper tubing including: filter dryer, SNMP recovery
without load
liquid sight glass, electronic expansion valve, discharge Weight (6) kg 2815 2865 2930 3649 3707 3747 3818 5360 5481 5638 5719
shut-off valve, pressure gauges, pressure switches and
high and low pressure transducers
• Shell & Tube evaporator insulated with closed-cell
expanded neoprene
• Shell & Tube condenser
• Water flow differential pressure switch for the evaporator
and condensers
• Electric panel conforming to EC standards (2006/95/EC
and EMC 2004/108/EC directives) with maximum internal
temperature control, auxiliary transformer, auxiliary general
cut off switch, fuses for compressors, cut off switches
• Phase sequence and min / max voltage control
• UPC1m microprocessor control system including:
- mP20II local user terminal visible externally and
accessible through a door panel Construction Options
- chilled water / hot discharge water temperature • Low noise version with sound proofed housing for the (*) on request
regulation compressors (**) available only for 1402A, 2002A, 2202A, 3202A,
- advanced start-up management with 8 partialization • Low external temperature version with anti- 3602A models
steps with automatic set-point regulation and condensation heater for the electrical panel and heaters
compressor rotation with FIFO logic (run time counter, for the evaporator and condensers Options
inrush counter and counter threshold for programmed • Condensers for sea water (*) • Pressostatic valve with integrated control for control
maintenance) • High condensation temperature version (**) software

© 2012 Schneider Electric. All rights reserved.


- advanced evaporator anti-freeze protection • Partial / total integrated condensation heat recovery • Remote control panel which allows:
- integrated LAN card for connection to the local network • Low temperature glycol water mixture production (down - display / modification of settings
of a group of chillers (up to 10 units with one or two in to -10°C) - display of activated alarms
reserve) • RS485 serial card for connection to the Uniflair • Spring anti-vibration anti-seismic supports
- modulating condensation control (with kit: see options) supervision system or an external BMS • Neoprene anti-vibration supports.
- clock card • LON FFT10 serial card for connection to an external
• The microprocessor control system also includes: BMS with LON protocol
- external evaporator pump group management • Power phase correction condensers
- set point adjustment from external 0-10V signal • Unit predisposed for outdoor installation (*)

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BRWC-BRWH 06/12
Water-cooled modulating water chillers for indoor installation 34 BCWC 35

Uniflair BCWC

Technical Data 1. Data refers to nominal


Range
conditions: In/out evaporator
BCWC MODEL 0320A 0630A 0950A 1250A
Cooling capacity: 300 ÷ 1300 kW Power supply V/ph/Hz 400 / 3 / 50
water temperature: 12/7°C;
In/out condenser water
Available versions Compressors nr, x mod 1 x centrifugal 2 x centrifugal 3 x centrifugal 4 x centrifugal temperature: 30/35°C;
Evaporator nr, x mod 1 x flooded Condenser fouling coefficient:
- basic
Condensers nr, x mod 1 x Shell & Tube 0,000043 m²°C/W; Evaporator
- sea water condersers (*)
Cooling only fouling coefficient: 0,000043
Refrigerant R-134a m²°C/W; R134a refrigerant
Cooling capacity (1) kW 320 630 950 1250
“oil-free” centrifugal compressors Absorbed power (1) kW 64 130 192 247 2. Integrated Partial Load
with magnetic bearings E.E.R. (1) kW 5,0 4,9 4,9 5,1 Value: based on ARI conditions

I.P.L.V. (2) 8,85 8,74 8,84 8,86 3. European Seasonal Energy


E.S.E.E.R. (3) 8,34 8,16 8,31 8,32 Efficiency Ratio
Noise levels 4. Measured in free field with
Noise pressure level (4) dB(A) 67,3 70,3 72,1 73,3 Q=2 directional factor, at a
Dimensions and weight distance of 1 mt. from the unit
Height mm 2028 2130 1924 1924 5. Data refers to unloaded units
Length mm 2640 2940 3294 4591
Standard Features power supply and voltage Width mm 1061 1022 1544 1505
• Self supporting metal frame in galvanised steel • UPC3m microprocessor control system including: Weight (5) kg 1585 2814 3752 5760
varnished in epoxy powders (colour RAL7037) - continuous control of the cooling capacity by means of
• Between one and four “oil free” centrifugal compressors an inverter and IGV (Inlet Guide Vane)
with magnetic bearings equipped with: - PGD local user terminal with external display
- internal thermal protection - outlet water temperature regulation
- protection and control of the rotation axis position - integrated LAN card for connecting more than one unit
- brushless synchronized DC motor to the local area network
- integrated control system - clock card
- speed control with inverter • The control system also features:
- soft start start-up - external pump group management for the evaporator
- phase sequence control - set-point modification by an external 0-10V signal
- pre-rotation valve - management of a double set-point with contact
- temperature and pressure sensors selection
- 2 centrifugal compressor stages - general alarm contact and 2 addressable alarms
- anti-vibration supports - remote ON-OFF control
• Single refrigerant circuit conforming to EC standards - ability to interface with Modbus protocol directly on
(PED 97/23/CE directive) with copper tubing including: RS485 serial card
filter dryer, liquid sight glass, electronic expansion valve - ability to interface with main external communication
controlled by a level sensor, discharge and suction taps protocols: Bacnet, Lonworks, Metasys, TCP/IP and
on the compressor, pressure switches, high and low SNMP
pressure transducers and gauges
• By-pass line for vacuum start-up with high pressure
ratio Construction Options Options
• Shell & Tube evaporator featuring an integrated de- • Condenser for sea water use (*) • Remote control panel which enables:
mister to prevent the formation of droplets: the exchanger • RS485 serial card for connection to Uniflair Supervision - the settings to be displayed / changed
is insulated with closed-cell expanded polyurethane system or an external BMS - alarm status to be displayed
• Differential water pressure switch for the evaporator and • LON FFT10 serial card for connection to an external • Neoprene anti-vibration supports
the condenser BMS with LON protocol
• Shell & Tube condenser
• Electric panel conforming to EC standards (2006 (*) on request

© 2012 Schneider Electric. All rights reserved.


/95 /EC and EMC 2004/108/EC directives) with EMC
integrated filter for protection of the harmonics, maximum
internal temperature control, auxiliary transformer, general
auxiliary cut-off switch, fuses on the compressors and
remote control cut-off switches
• Line reactance for each compressor to stabilize the
power supply
• Phase sequence control and minimum / maximum

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BCWC 06/12
Condenserless chiller with remote condenser 36 BRRC 37

Uniflair BRRC

Range Technical Data 1. Data refer to nominal


conditions: Evaporator in/out
Cooling capacity: 300 ÷ 1200 kW BRRC MODEL 1402A 1602A 1802A 2002A 2202A 2502A 2802A 3202A 3602A 4202A 4802A
water temperature: 12/7°C;
Power supply V/ph/Hz 400 / 3 / 50
Available versions Condenser temperature: 50°C;
Compressors nr. x mod 2 x Semi hermetic double screw Evaporator fouling coefficient:
- Basic Evaporator nr. x mod 1 x Shell & Tube 0,000043 m2°C/W; R134a
- High condensing water temperature (**) Cooling capacity (1) kW 284,0 336,0 377,0 414,0 482,0 551,0 630,0 726,0 842,0 938,0 1069,0 refrigerant
Absorbed power (1) kW 88,7 100,3 115,5 122,2 143,9 159,0 176,3 208,3 244,0 272,0 299,8
Refrigerant R-134a 2. Measured in free field with
Double screw compressors E.E.R. mod 3,2 3,4 3,3 3,4 3,4 3,5 3,6 3,5 3,5 3,5 3,6 Q=2 directionality factor, at 1
Noise levels mt. from the unit
Noise pressure level 3. Data refer to a basic version
dB(A) 73,5 73,7 73,8 78,0 79,5 79,7 79,6 77,3 75,3 76,3 78,4
basic version (2) empty unit
Noise pressure level
dB(A) 64,0 63,9 64,6 68,5 69,6 68,7 72,4 69,3 69,1 71,8 72,5
LN version (2)
Dimensions and weight
Height mm 2010 2010 2010 2010 2010 2010 2010 1870 1870 1870 1870
Length mm 3700 3700 3700 3700 3700 3900 3900 4130 4130 4130 4130
Width mm 850 850 850 850 850 850 850 1400 1400 1400 1400
Standard Features • The microprocessor control system also includes: Weight (3) kg 2335 2385 2420 3139 3159 3191 3212 4616 4737 4858 4939
• Self-supporting frame in galvanised steel with panels - external evaporator pump group management
finished in epoxy powders (colour RAL7037) - set point adjustment from external 0-10V signal
• Two semi-hermetic double screw compressors with - double set-point management with contact selection
internal thermal protection, oil heaters and anti-vibration - general alarm contact and 2 addressable alarms
supports - ON-OFF remote contact
• Two refrigerant circuits conforming to EC standards - ability to interface with main external communication
(PED 97/23/CE) in copper tubing including: filter dryer, protocols: Modbus, Bacnet, Lonworks, Trend, Metasys,
liquid sight glass, electronic expansion valve, discharge TCP/IP and SNMP
shut-off valve, pressure gauges, pressure switches and
high and low pressure transducers
• Shell & Tube evaporator insulated with closed-cell
expanded neoprene
• Evaporator water flow pressure switch
• Electric panel conforming to EC standards (2006/95/EC
and EMC 2004/108/EC directives) with maximum internal
temperature control, auxiliary transformer, general cut off
switch, fuses for compressors, cut off switches
• Phase sequence and min / max voltage control
• UPC1m microprocessor control system including:
- mP20II local user terminal visible externally and
accessible through a door panel
- outlet chilled water temperature
- advanced start-up management with 8 partialization
steps with automatic set-point regulation and Construction Options Options
compressor rotation with FIFO logic (run time counter, • Low-noise version with sound proofed housing for the • Remote control panel which allows:
inrush counter and counter threshold for programmed compressors - display / modification of settings
maintenance) • Low temperature water production (to -10°C) - display of activated alarms
- advanced evaporator anti-freeze protection • RS485 Serial card for connection to the Uniflair • Spring anti-vibration supports
- integrated LAN card for connection to the local network supervision system or an external BMS • Neoprene anti-vibration supports
of a group of chillers (up to 10 units with one or two in • LON FFT10 serial card for connection to an external

© 2012 Schneider Electric. All rights reserved.


reserve) BMS with LON protocol
- clock card • Power phase correction condensers
• Unit predisposed for outdoor installation (*)

(*) on request
(**) available only for 1402A, 2002A, 2022A, 3202A,
3602A models

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
BRRC 06/12
Air-cooled water chillers and heat pumps with backward curved blade fans 38 ERCC - ERCH 39

Uniflair ERCC - ERCH

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 50 ÷ 120 kW ERCC/ERCH MODELS 0521A 0621A 0721A 0821A 0921A 0922A 1021A 1022A 1221A 1222A
12/7°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 0%; 50Pa; R410A
Refrigerant circuits nr. 1 1 1 1 1 2 1 2 1 2 refrigerant
- low noise Compressors nr. x mod 2 x Scroll
2. Data refer to the total
- ultra low noise Fans nr. 2 2 2 3 3 3 3 3 4 4
absorbed power (compressors
Evaporator nr. 1 1 1 1 1 2 1 2 1 2
Refrigerant R-410A and fans)
Scroll compressors Evaporator mod Plate
3. Data refer to nominal
ERCC - standard fans
conditions: water temperature
Cooling capacity (1) kW 48 57 66 76 84 85 97 97 113 113 40/45°C, external temperature
Absorbed power (1) kW 16,7 20,4 22,7 26,2 30,0 30,0 34,4 34,4 40,5 40,5 7°C dry bulb, 6°C wet bulb;
E.E.R. (2) 2,85 2,78 2,90 2,91 2,81 2,82 2,83 2,82 2,79 2,79 50Pa; R410A refrigerant
E.S.E.E.R. (5) 3,54 3,85 4,09 3,86 3,90 3,75 3,99 3,84 3,98 3,98 4. Data measured in free field
ERCH - standard fans at 1 mt. from the ducted unit at
Heating capacity (3) kW 59 69 79 92 102 n.a. 118 n.a. 138 n.a. nominal conditions, coil side,
Absorbed power (3) kW 17,9 20,9 23,2 27,7 30,9 n.a. 35,7 n.a. 42,3 n.a. Q=2 directional factor

C.O.P. (2) 3,29 3,29 3,40 3,32 3,30 n.a. 3,30 n.a. 3,26 n.a. 5. European Seasonal Energy
Standard Features - Production of chilled water to -15°C Noise pressure level (4) dB(A) 67,5 67,6 67,5 69,1 69,1 69,1 71,2 71,2 72,5 72,5 Efficiency Ratio
• Self supporting frame in galvanised steel with panels - Anti-freeze protection ERCC - EC Fans 6. Data refer to an empty unit
varnished with epoxy powders (colour RAL7037) - Compressor timing and protection Cooling capacity (1) kW 48 57 66 76 84 85 97 97 113 113 without pump and water tank
• Access panel to the unit equipped with handles and fast - Compressor rotation based on FIFO logic Absorbed power (1) kW 16,7 20,4 22,8 26,2 30,0 30,0 34,5 34,5 40,6 40,6
screws - Pump rotation on a timed basis for equal operation and E.E.R. (2) 2,85 2,78 2,89 2,91 2,81 2,82 2,82 2,81 2,80 2,80
• Two hermetic scroll compressors with internal thermal startup of the stand-by pump (with alarm signal) in the E.S.E.E.R. (5) 4,02 4,23 4,42 4,28 4,27 4,13 4,41 4,21 4,40 4,39
protection, anti-vibration supports and crankcase heaters event of a breakdown ERCH - EC Fans
(ERCH and low ambient temperature versions) - Display of compressor operating hours Heating capacity (3) kW 56 65 76 87 97 n.a. 113 n.a. 131 n.a.
• Single refrigerant circuit (*) conforming to EC Directives - Alarm code signal Absorbed power (3) kW 17,1 20,3 22,2 26,6 30,1 n.a. 33,7 n.a. 40,7 n.a.
(PED 97/23/CE) in copper tubing including filter dryer, - General alarm with clean signal contact C.O.P. (2) 3,25 3,23 3,41 3,29 3,22 n.a. 3,36 n.a. 3,22 n.a.
liquid sight glass, dual flow thermostatic valve with - ON-OFF remote contact Noise pressure level (4) dB(A) 65,2 65,3 65,3 66,8 66,8 66,8 69,9 69,9 71,2 71,2
external equalisation, high and low pressure switches and Dimensions and weights
high pressure transducers Height mm 1836 1836 1836 1836 1836 1836 2146 2146 2146 2146
• Environmentally friendly R410A Refrigerant Depth mm 1190 1190 1190 1190 1190 1190 1190 1190 1190 1190
Top Level Options
• Water side brazed plate heat exchanger in stainless Width mm 2006 2006 2798 2798 2798 2798 3067 3067 3067 3067
• Electronic expansion valve directly controlled by the
steel insulated with closed cell expanded polyurethane Weight ERCC basic (6) kg 773 778 921 957 963 974 1197 1196 1232 1232
unit microprocessor control
• Water flow differential pressure switch Weight ERCH basic (6) kg 797 802 951 987 994 n.a. 1241 n.a. 1276 n.a.
• Single suction back ward cur ved fans with
• Free-cooling air side exchange coil with aluminium fins
electronically commutated motor (EC)
and mechanically-expanded copper tubes
• Evolved UpCO1m control for:
• Refrigerant side cycle inversion with 4-way inversion
- Discharge water temperature regulation
valve (ERCH)
- Management of the electronic thermostatic valve
• Single suction backward curved blade centrifugal fans.
- Monitoring of the refrigerant load
The external tri-phase rotary electric motor is directly
- Self-adjustment of the set-point regulation
coupled and has an IP54 Class F equipped with internal Construction Options • Evaporator, water tank and pump group anti-freeze
- Evolved defrost operation management (ERCH)
thermal protection (klixon). The fan impeller is • Ultra low noise version by means of sound-proofing the heaters
- Integrated LAN card
dynamically and statically balanced and the cushions are compressors • Modification of the set point by external 0-10V signal
- Compatibility with the most common external BMS
sealed and lubricated for life • Partial / total condensation heat recovery • EC fans
and with the Modbus protocol using only a RS485
• Modulating condensation control based on the • Integrated hydraulic module with one or two pumps (1
card
condensation pressure + 1 stand-by) with heat-protected circulation, expansion Options
• Electrical panel conforming to EC Directives vessel and safety valve • Remote user terminal
(2006/95/EC and EMC 2004/108/EC) protection grade • Internal water tank • Clock card

© 2012 Schneider Electric. All rights reserved.


IP54 with auxiliary transformer, lockable general cut off (*) ERCC with (**) 22A suffix are available with two • RS485, FTT10 or TCP/IP serial card
• Internal water tank including a pump to manage the
switch, magneto-thermal compressors on two circuits • Metal filters and protection grilles for the condensing
primary circuit
cut off switches and remote control • Power factor improvement compressors coils
• Sequence phase control • Compressor Softstart • Rubber or spring anti-vibration supports
• Anti-condensation heaters for the electrical panel (ERCH • Cataphoresis treatment for the condensing coils
and low ambient temperature versions) • Shut off taps on the compressor discharge
• Microprocessor control system including:
- Local user terminal
- Chilled / hot water temperature regulation (ERCH)

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ERCC-ERCH 06/12
Air-cooled modulating water chillers and heat pumps with backward curved blade fans 40 ISCC - ISCH 41

Uniflair ISCC - ISCH

Range Technical Data 1. Data refer to nominal


conditions: water temperature:
Cooling capacity: 60 ÷ 120 kW ISCC/ISCH MODELS 0621A 0921A 1221A
12/7°C; external temperature
Heating capacity: 66 ÷ 130 kW Power supply V/ph/Hz 400 / 3 + N / 50
35°C; glycol 0%; inverter
Refrigerant circuits nr. 1 1 1 compressor at 90rps R410A
Available versions
Compressors nr. 1 ON/OFF + 1 inverter driven (Scroll) refrigerant; 50Pa
- low noise Fans nr. 2 3 4
2. Data refer to total absorbed
Evaporator nr. 1 1 1
Refrigerant R-410A power (compressors and fans)
Inverter driven Scroll compressors Evaporator mod Plate
3. Data refer to nominal
ISCC – Low noise version
conditions: water temperature
Cooling capacity (1) kW 59,7 88,1 117,0 40/45°C, external temperature
Absorbed power (1)(2) kW 21,4 30,8 41,4 7°C dry bulb 6°C wet bulb;
E.S.E.E.R. (4) 3,98 4,42 4,35 inverter compressor 90rps;
I.P.L.V. (5) 5,63 5,70 5,66 R410A refrigerant; 50Pa

ISCH – Low noise version 4. European Seasonal Energy


Heating capacity (3) kW 67,4 98,7 131,0 Efficiency Ratio
Absorbed power (3)(2) kW 21,5 31,2 42,5 5. Integrated Partial Load Value
Noise pressure level (6) dB(A) 67,6 69,1 72,5
6. Data measured in free
Standard Features and mechanically expanded copper piping ISCC – Low noise version (EC) field conditions at 1m from
• Self-supporting galvanized sheet steel framework with • Backward curved blade single aspiration centrifugal fans Cooling capacity (1) kW 59,8 88,2 117,1 the ducted unit operating at
panels painted with epoxy powder paints (colour RAL with directly coupled motor. The impeller is statically and Absorbed power (1)(2) kW 21,4 30,8 41,4 nominal conditions, coil side,
7037) equipped with fast screws for easy and quick dynamically balanced and the bearings are sealed and E.S.E.E.R. (4) 3,98 4,42 4,35 directional factor Q=2
access lubricated for life. I.P.L.V. (5) 5,63 5,70 5,66 7. Data refer to an empty unit
• Inverter-driven hermetic Scroll compressor, equipped • Modulating condensation control by means of ISCH – Low noise version (EC) without pump
with continuous fan speed control Cooling capacity (1) kW 67,4 98,7 131,2
- Inverter speed control • Electrical panel in accordance with EC standards Absorbed power (1)(2) kW 21,6 31,2 42,5
- Oil by-pass valve and line (directive 73/23/EC and directive EMC 89/336/EC) IP54 Noise pressure level (6) dB(A) 65,3 66,8 71,2
- Soft start protection grade with auxiliary transformer, minimum and Dimensions and weights
- Integrated power factor correction condenser maximum temperature control, general door interlock cut Height mm 1560 1560 1874
- Integrated thermal protection off switch, protection and remote control switches Length mm 1190 1190 1192
- Anti-vibration supports • Phase sequence control Width mm 2008 2798 3075
• Inverter driver with IP54 protection grade coupled with • UPC1m microprocessor control including: Weight ISCC (basic version) (7) Kg 818 1179 1277
a specific compressor and positioned in a dedicated - Chilled / hot water temperature regulation by means of Weight ISCH (basic version) (7) Kg 848 1209 1322
housing compartment self adaption of the set point regulation band
• Compressor sound-proofing with noise insulating - Management of the electronic thermostatic valve
jackets and, only for model 1221A, soundproofing of the - Compressor management driven by inverter
compressor compartment - Quick start start-up procedure
• Vibration absorbers on the compressor discharge and - Integrated LAN card
suction line (only for model 1221A) - Integrated clock card
• Single refrigerant circuit in accordance with EC - Compatibility with Modbus protocol via RS485
standards (directive PED 97/23/CE) in copper piping - Compatability with the most common external BMS:
including dehydration filter, liquid sight glass, electronic LONworks, BacNET, TCP/IP, Trend Construction Options Options
expansion valve connected to and driven by the unit • Integrated hydraulic module with one or two pumps • Remote user terminal mP20 II (up to 200 metres) for:
control, high and low pressure switches and transducers. (1+1 in stand-by) with heat protected circulation, - entering of commands
The refrigerant circuit features an exclusive patented expansion vessel and safety valve - display unit status and alarms
system for optimum lubrification management of the • Integrated hydraulic module with one or two inverter • RS485 serial adaptor used to communicate with the
tandem compressors driven pumps (1+1 in stand-by) with heat protected Uniflair supervisory system or to interface with external
• Continuous operation up to -20°C (only ISCC) circulation, expansion vessel and safety valve BMS
• Environmentally friendly refrigerant R410A • Cataphoresis treatment for condensing coils • LON F T T10 serial adaptor used to communicate with

© 2012 Schneider Electric. All rights reserved.


• Crankcase heaters and inverter with oil heating function • Shut-off taps on the compressor discharge external BMS managed with LON protocol
• Brazed plate water side heat exchangers in stainless • Power factor correction on compressors • TCP/IP serial adaptor used to communicate with
steel, insulated with closed-cell expanded polyurethane • Modification of the set-point by external signal 0-10V external BMS managed with SNMP protocol
and anti-freeze heaters • Intelligent free-cooling (only with onboard pump) • Air side coil protection filters and grills
• Refrigerant side cycle inversion with 4-way inversion • EC fans • Rubber or spring anti-vibration supports
valve (only ISCH)
• Water flow differential pressure switch
• Air side exchange coil and free-cooling coil with
aluminium fins

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ISCC-ISCH 06/12
Air-cooled water chillers with backward curved fans and free-cooling system 42 ERCF 43

Uniflair ERCF

Range Technical Data 1. Data refer to nominal


conditions: water temperature
Cooling capacity: 50 ÷ 110 kW ERCF MODEL 0521A 0621A 0721A 0821A 0921A 0922A 1021A 1022A 1221A 1222A
10/15°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 20%; 50Pa; R410A
Fans nr. 2 2 2 3 3 3 3 3 4 4 refrigerant
- low noise Refrigerant circuits nr. 1 1 1 1 1 2 1 2 1 2
2. Data refer to the total
- ultra low noise Compressors nr. x mod 2 x Scroll
absorbed power (compressors
Evaporator nr. 1 1 1 1 1 2 1 2 1 2
Refrigerant R-410A and fans)
Scroll compressors Evaporator mod Plate
3. Data refer to nominal
ERCC - standard fans
conditions: inlet water
Cooling capacity (1) kW 51 61 71 82 90 91 104 104 121 122 temperature 15°C; external
Absorbed power (1)(2) kW 17,2 21,0 23,3 26,9 30,9 30,9 35,3 35,3 41,7 41,8 temperature 5°C; glycol 20%;
E.E.R. (2) 2,97 2,89 3,04 3,04 2,93 2,94 2,96 2,96 2,90 2,91 50Pa
Capacity in free-cooling (3) kW 39 41 47 57 59 59 68 68 80 80 4. Data refer to the absorbed
E.E.R. (3)(4) 8,31 8,81 8,83 7,75 8,02 8,02 9,38 9,37 8,50 8,51 power of the fans and free-
Noise pressure level (5) dB(A) 67,5 67,6 67,5 69,1 69,1 69,1 71,2 71,2 72,5 72,5 cooling pump
ERCF - EC fans 5. Data measured in free
Cooling capacity (1) kW 51 61 71 82 91 91 105 104 121 122 field at 1 mt. from the ducted
Standard Features - Pump rotation on a timed basis for equal operation and Absorbed power (1)(2) kW 17,1 20,8 23,3 26,7 30,7 30,7 35,2 35,2 41,4 41,4 unit operating at nominal
• Exclusive free-cooling system managed completely by startup of the stand-by pump (with alarm signal) in the E.E.R. (2) 3,00 2,91 3,04 3,07 2,95 2,97 2,97 2,96 2,93 2,94 conditions, coil side, Q=2
the microprocessor control event of a breakdown directional factor
Capacity in free-cooling (3) kW 39 42 47 58 60 60 68 68 80 80
• Self supporting frame in galvanised steel with panels - Display of compressor operating hours E.E.R. (3)(4) 8,53 9,06 8,81 7,95 8,23 8,23 9,42 9,41 8,74 8,75 6. Data refer to an empty unit
varnished with epoxy powders (colour RAL7037) - Alarm code signal Noise pressure level (5) dB(A) 65,2 65,3 65,3 66,8 66,8 66,8 69,9 69,9 71,2 71,2 without pump and water tank
• Access panel to the unit equipped with fast screws - General alarm with clean signal contact Dimensions and weights
• Two hermetic Scroll compressors with internal thermal - ON-OFF remote contact Height mm 1836 1836 1836 1836 1836 1836 2146 2146 2146 2146
protection, anti-vibration supports and crankcase heaters Depth mm 1190 1190 1190 1190 1190 1190 1190 1190 1190 1190
• Single refrigerant circuit (*) conforming to EC Directives Width mm 2006 2006 2798 2798 2798 2798 3067 3067 3067 3067
(PED 97/23/CE) in copper tubing including filter dryer, Top Level Options
Weight (6) kg 866 871 1045 1082 1088 1099 1351 1350 1385 1385
liquid sight glass, dual flow thermostatic valve with • Electronic expansion valve directly controlled by the
external equalisation, high and low pressure switches and unit microprocessor control
high pressure transducers • Single suction backward curved fans with
• Environmentally friendly refrigerant R410A electronically commutated motor (EC)
• Water side brazed plate heat exchanger in stainless • Evolved UpCO1m control for:
steel insulated with closed cell expanded polyurethane - Discharge water temperature regulation
• Air side free-cooling exchange coil with aluminium fins - Management of the electronic thermostatic valve
and mechanically-expanded copper tubes - Monitoring of the refrigerant load
• Free-cooling pump driven by the microprocessor control - Self-adjustment of the setpoint regulation
• Water flow differential pressure switch - Evolved defrost operation management (ERCH)
• Single suction backward curved blade centrifugal fans. - Integrated LAN card
The external tri-phase rotary electric motor is directly - Compatibility with the most common external BMS
coupled and has an IP54 Class F equipped with internal and with the Modbus protocol using only a RS485
thermal protection (klixon). The fan impeller is dynamically card Construction Options • Shut off taps on the compressor discharge
and statically balanced and the cushions are sealed • Ultra low noise version by means of sound-proofing the • Evaporator, water tank and pump group anti-freeze
and lubricated for life compressors heaters
• Modulating condensation control based on the (*) ERCC with (**) 22A suffix are available with two • Partial / total condensation heat recovery • Modification of the set point by external 0-10V signal
condensation pressure compressors on two circuits • Integrated hydraulic module with one or two pumps (1
• Electrical panel conforming to EC Directives + 1 stand-by) with heat-protected circulation, expansion Options
(2006/95/EC and EMC 2004/108/EC) protection grade vessel and safety valve • Remote user terminal
IP54 with auxiliary transformer, lockable general cut off • Internal water tank • Clock card

© 2012 Schneider Electric. All rights reserved.


switch, magneto-thermal cut off switches and remote • Internal water tank including a pump to manage the • RS485, FTT10 or TCP/IP serial card for connection to
control primary circuit the Uniflair supervision system of an external BMS
• Sequence phase control • Power factor improvement compressors • Metal filters and protection grilles for the condensing coil
• Microprocessor control system including: • Compressor Softstart • Rubber or spring anti-vibration supports
- Local user terminal • Cataphoresis treatment for the condensing and Free-
- Chilled / hot water temperature regulation (ERCH) cooling coils
- Anti-freeze protection
- Compressor timing and protection
- Compressor rotation based on FIFO logic

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ERCF 06/12
Air-cooled modulating water chillers and heat pumps with backward curved blade fans and free-cooling system 44 ISCF 45

Uniflair ISCF

Range Technical Data 1. Data refer to nominal


conditions: water temperature:
Cooling capacity: 60 ÷ 120 kW ISCF MODEL 0621A 0921A 1221A
15/10°C; external temperature
Power supply V/ph/Hz 400 / 3 + N / 50
Available versions 35°C; glycol 20%; inverter
Refrigerant circuits nr. 1 1 1 compressor at 90 rps; R410A
- low noise Compressors nr. 1 ON/OFF + 1 inverter driven (Scroll) refrigerant; ESP=50Pa
Fans nr. 2 3 4
Refrigerant R-410A 2. Data refer to total absorbed
Evaporator nr. 1 1 1
Inverter driven Scroll compressors power (compressors and fans)
Evaporator mod Plate
3. Data refer to nominal
ISCF – Low noise version
conditions: inlet water
Cooling capacity (1) kW 64,7 95,3 126,8 temperature 15°C, external
Absorbed power (1)(2) kW 22,0 31,5 42,4 temperature 5°C; glycol 20%;
Capacity in free-cooling (3) kW 43,6 62,7 84,0 inverter compressor at 90 rps;
Absorbed power in free-cooling (3)(4) kW 4,6 7,3 9,2 R410A refrigerant; ESP=50Pa

E.E.R. in free-cooling (4) 9,5 8,6 9,1 4. Data refer to total absorbed
Noise pressure level (5) dB(A) 67,6 69,1 72,5 power (fans and free-cooling
Dimensions and weights pump)

Height mm 1560 1560 1874 5. Data measured in free


Standard Features aluminium fins and mechanically expanded copper piping Length mm 1190 1190 1192 field conditions at 1m from
• Exclusive free-cooling system completely managed by • Backward curved blade single aspiration centrifugal fans Width mm 2008 2798 3075 the ducted unit operating at
the control system with directly coupled motor. The impeller is statically and nominal conditions, coil side,
Weight (basic version) (6) Kg 751 935 1212
directional factor Q=2
• Self-supporting galvanized sheet steel framework with dynamically balanced and the bearings are sealed and
panels painted with epoxy powder paints (colour RAL lubricated for life. 6. Data refer to an empty unit
7037) equipped with fast screws for easy and quick • Modulating condensation control by means of without pump

access continuous fan speed control


• Inverter-driven hermetic Scroll compressor, equipped • Electrical panel in accordance with EC standards
with (directive 73/23/EC and directive EMC 89/336/EC) IP54
- Inverter speed control protection grade with auxiliary transformer, minimum and
- Oil by-pass valve and line maximum temperature control, general door interlock cut
- Soft start off switch, protection and remote control switches
- Integrated power factor correction condenser • Phase sequence control
- Integrated thermal protection • UPC1m microprocessor control including:
- Anti-vibration supports - Chilled / hot water temperature regulation by means of
• Inverter driver with IP54 protection grade coupled with self adaption of the set point regulation band
a specific compressor and positioned in a dedicated - Management of the electronic thermostatic valve
housing compartment - Compressor management driven by inverter
• Compressor sound-proofing with noise insulating - Quick start start-up procedure
jackets and, only for model 1221A, soundproofing of the - Integrated LAN card
compressor compartment - Integrated clock card
• Vibration absorbers on the compressor discharge and - Compatibility with Modbus protocol via RS485
suction line (only for model 1221A) - Compatability with the most common external BMS:
• Single refrigerant circuit in accordance with EC LONworks, BacNET, TCP/IP, Trend Construction Options Options
standards (directive PED 97/23/CE) in copper piping • Integrated hydraulic module with one or two pumps • Remote user terminal mP20 II (up to 200 metres) for:
including dehydration filter, liquid sight glass, electronic (1+1 in stand-by) with heat protected circulation, - entering of commands
expansion valve connected to and driven by the unit expansion vessel and safety valve - display unit status and alarms
control, high and low pressure switches and transducers. • Integrated hydraulic module with one or two inverter • RS485 serial adaptor used to communicate with the
The refrigerant circuit features an exclusive driven pumps (1+1 in stand-by) with heat protected Uniflair supervisory system or to interface with external
patented system for optimum lubrification management of circulation, expansion vessel and safety valve BMS
the tandem compressors • Intelligent free-cooling (only with onboard pumps) • LON F T T10 serial adaptor used to communicate with

© 2012 Schneider Electric. All rights reserved.


• Continuous operation up to -25°C • Cataphoresis treatment for condensing and free-cooling external BMS managed with LON protocol
• Environmentally friendly refrigerant R410A coils • TCP/IP serial adaptor used to communicate with
• Crankcase heaters and inverter with oil heating function • Shut-off taps on the compressor discharge external BMS managed with SNMP protocol
• Brazed plate water side heat exchangers in stainless • Power factor correction on compressors • Air side coil protection filters and grills
steel, insulated with closed-cell expanded polyurethane • Modification of the set-point by external signal 0-10V • Rubber or spring anti-vibration supports
and anti-freeze heaters • EC fans
• Pump for free-cooling circuit
• Water flow differential pressure switch
• Air side exchange coil and free-cooling coil with

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
ISCF 06/12
Fan coil cassette units for underfloor installations 46 UTAT 47

Uniflair UTAT

Technical Data 1. Inlet chilled water


Range temperature: 7°C, water
UTAT 0030B MODEL 1° SPEED 2° SPEED 3° SPEED
flow; 250 l/h; air ambient
Cooling capacity (1) kW 1,74 1,99 2, 45
Cooling capacity: 1 ÷ 2 kW temperature: 27°C d.b., 19°C
Sensibile cooling capacity (1) kW 1,28 1,47 1,92
Heating capacity: 1 ÷ 3 kW w.b.
Airflow m3/h 221 280 438
Axial Fan 2. Inlet hot water temperature:
Absorbed power (1) W 25 32 40
45°C, water flow; 250 l/h; air
Heating capacity (2) kW 1,62 1,96 2,70 ambient temperature: 20°C
Noise pressure level (3) dB(A) 30 38 44 d.b.
DIMENSIONS
3. Values measured at 1 mt. in
Weight (basic version) kg 10 10 10 free field conditions from the
unit with Q=2 directionality
factor

Standard Features Options Dimensioni


• Structure manufactured in thermoformed plastic, with • Self-priming condense discharge pump with heat
bearing parts in galvanised steel protection and alarm on NC resistive contact
• 2 rows, thermal exchange pack coil with expanded • RS485 serial adaptor
copper tubing and aluminium fins, collectors with • Can-bus serial adaptor
threaded air outlet connectors. The coil has been tested • Remote user terminal
at a pressure of 10 bar • Incorporate NTC sensor for ambient temperature
• Four blade axial fan manufactured in PP 30% GV adjustment 520

stabilised to UV rays, statically and dynamically balanced • LCD display with intuitive symbols 490
on two levels • Selection of the value to display (temperature, set-point,
• 230V/1/50Hz winding induction motor with constantly offset compared with common set-point)
inserted condenser. Class B insulation. Declared to • Selective key block (limited functions for offices,
conform with electromagnetic compatibility (according to hotels...)
2004/108 /EC, CE92/31, CE93/68 Directives) and low • Signalling of coded alarms and faults
voltage directives (Section 10, Directive 2006/95/EC), • ON-OFF timer functions
IP44 protection level. Three rotation speeds. • Economy-sleep function
Electrical Panel Air-filter around
• CE Directive electrical panel (Directives 2006/95/EC and • Manual or automatic operation cold/hot water coil
EMC 2004/108/EC) with unit control card equipped with
incorporated relays
• Thermoformed plastic condensation collection tray
• Cleanable filter in self-extinguishing material Inlet water 1/2” Electrical
supplied with galvanised plate hooks F GAS connection
• 230V/1/50Hz Power supply 522

230

© 2012 Schneider Electric. All rights reserved.


560

Outlet water 1/2” F GAS Condensate drainage


pump

Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
UTAT 06/12
Underfloor air distribution module 48 UTCT 49

Uniflair UTCT

Technical Data FAN 1. Values measured at 1 mt. in


Range free field conditions from the
MODEL UTCT 00600 Speed Airflow Lw Lp
unit with Q=2 directionality
Airflow m3/h 400-990(modulating) m3/h dB(A) dB(A)
Airflow: 400 – 990 m /h
3
factor
Max fan absorbed power W 60 1 400 - -
Operating mode Max fan absorbed current A 0,5 2 430 38 26
2. Data refer to UTCT in
standard configuration
Underfloor air distribution Electrical heater W 500 3 500 42 30
Ambient air recirculation Min free space under floor mm 275 4 580 47 35
Heating mode DIMENSIONS AND WEIGHT 5 680 54 42
Width mm 598 6 770 55 43
Modulating EC fan
Depth mm 780 7 850 56 44
Modulating damper
Height mm 265 8 900 57 45
Integrated control board
Weight kg 27 9 970 60 46
AMBIENT TEMPERATURES 10 990 64 47
Operating °C 0/45
Storage °C -40/+80

Standard Features Operating mode Dimensioni


• Self-supporting structure in galvanized steel The unit can operate with 3 different configurations,
• Pod system designed to provide a high level of stability according to the position of the modulating damper:
and to be compatible with Uniflair UNI8 evolution structure • Total cooling / total heating
or other equivalent access flooring structures - Damper completely open on underfloor side: air suction
• Installation integrated under a raised floor. The module is from underfloor and discharge in the ambient
Grills and floor not
connected to the access floor structure stringers through - Electrical heater (optional) operates in heating mode to included
the four sides reach rapidly the set-point required until the underfloor
• Dual Electronic Commutated motor centrifugal fan, temperature is adequate
manufactured in PP, with anti-vibration motor mounted on • Recirculation
both sides and thermal overload protector (TOP) internally - Damper completely closed on underfloor side: air
wired. Product complying with standard EN 60335-1. suction and discharge from and in the ambient
Class F insulation. IP44 protection level. 10 rotation • Mixed mode
speeds. - Damper partially open on underfloor side: air suction Electrical
• Modulating motorized air damper with 10 different mixed from the ambient and from underfloor and panel side
positions (from 0% to 100%) discharge in the ambient Underfloor damper side
• Electric board complying with EC standards (2006 /95 / The correct configuration that ensures the set-point
EC and EMC 2004/108/EC directives) required is managed by the microprocessor control
• No. 3 air temperature sensors onboard (inlet air from board. This acquires the air temperature from both inlet 598
the room, inlet air from underfloor and discharge air in the and outlet unit air side, by means of onboard temperature
room) sensors. According to the difference between ambient
• Wall-mounted remote user terminal (*) with NTC sensor temperature (*) and set-point (**), it automatically set the
IN
onboard for ambient temperature acquisition best configuration (damper position and fan speed) in Supply IN/OUT
• Microprocessor control board for automatic or manual order to guarantee the required set-point.

265
IN/OUT pLan user terminal
operation:
BMS
- automatic regulation based on ambient temperature (*) (*) on Master unit only
and room set point (defined with the TUL or by the (**) acquired from remote user terminal (TUL) or from the
BMS); unit air inlet temperature probe.
518
- manual selection of fan regulation (10 speeds) (***) defined by the remote user terminal (TUL) or by the
- manual selection of motorized air damper (10 positions) BMS system
• 230V/1ph/50-60Hz power supply 151,5 199,5 159,5

© 2012 Schneider Electric. All rights reserved.


Options • RS485 serial adaptor
The units can be supplied with the following external • Can-bus serial adaptor
accessories: • Konnex serial adaptor
• 500W aluminum fins electrical heater with safety • Wireless remote user terminal
thermostat and automatic restart • Signaling of coded alarms and faults (*)
• Cleanable filter in self-extinguishing material with
galvanized plate edge, suitable for high temperatures (*) if connected to a BMS system
596

780
Schneider Electric Uniflair SpA Viale della Tecnica, 2 35026 Conselve (PD) Italy Telephone: +39 049 5388211 schneider-electric.com uniflair.com
UTCT 06/12
© 2012 Schneider Electric. All rights reserved.

Uniflair SpA
Viale della Tecnica, 2
35026 Conselve (PD) Italy
Telephone: +39 049 5388211
Fax: +39 049 5388212
info@uniflair.com
schneider-electric.com
uniflair.com

Owned and directed by Schneider Electric SA

05RE0003B1A rev.1.0