Вы находитесь на странице: 1из 12

FX NT Unit version F FANT-F AC

1 Identification 2

2 Introduction 2

3 Features and Application Notes 2

4 General Description 3

5 Functional Description 4

6 External Interfaces 6

7 Alarm Control Unit 9

8 Physical Description 10

9 Power Supply 12

3FE 53701 ACAA TQZZA Ed 02 Released 1 / 12


FANT-F AC FX NT Unit version F

1 Identification

Table 1 provides identification of the FANT-F AC.

Table 1: Identification of the FANT-F AC

Part Number Mnemonic Name

3FE 53701 AC FANT-F AC Combined NT Unit version F

2 Introduction

This document describes the Combined NT Unit version F (FANT-F) which is part of the
7360 Intelligent Services Access Manager (7360 ISAM) FX.

3 Features and Application Notes

The FANT-F AC:


• Is an NT board with a 480 Gbps switch
• Can be used in a 7360 ISAM FX subrack.
• Performs all management and alarm handling functions for the ISAM subrack and all
the client devices mounted in the subrack or connected to the subrack, and supports
the management and control interfaces required for this task.
• Has four SFP+ 10Gigabit Ethernet (10GE) interfaces
The SFP+ interfaces support 1 GE and 10 GE data rates.
• Has one 10/100/1000BASE-T interface
• Supports NT I/O.
• Supports:
• Building Integrated Timing Source (BITS)
• Synchronized Ethernet (SyncE)
• External NTR Daisy-Chain output interface: 8KHz and 19.44MHz
Note: For a complete overview, refer to the 7360 ISAM FX Product Information.
• Supports synchronous Ethernet link data clock extraction for Network Timing
Reference (NTR) use:
• from the SFP+ interfaces on its own front plate
• from two 1 GE or 10 GE interfaces on the NTIO board

3FE 53701 ACAA TQZZA Ed 02 Released 2 / 12


FX NT Unit version F FANT-F AC

• Can be used in the following operational conditions:


• in Central Office (CO) environment with multiple 7360 ISAM FX subracks (as
described in the 7360 ISAM FX Hardware Installation Manual), the ambient
temperature can be between -5°C to +45°C
• in a single 7360 ISAM FX subrack, the ambient temperature can be between -40°C to
+70°C
• Is hot-swappable
• Consists of components which are compliant to the regulations of Reduction of
Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment
(WEEE).
• Is compliant to safety standards IEC / EN 60950-1 and AS/NZS 60950-1, provided
that it is installed, maintained and used according the relevant installation
instructions.

4 General Description

The FANT-F AC NT board is responsible for:


• the routing/switching and the aggregation of end-user data streams to and from
network interfaces and/or uplink interfaces.
• Centralized shelf control and management
• System clock generation
• Network Timing Reference (NTR) generation, Synchronous Equipment Timing
Source (SETS).
• Centralized shelf alarm handling and reporting (Alarm Control Unit (ACU)
functionality).

The LT boards are responsible for the physical termination of user interfaces and non-
blocking user aggregation.
The FANT-F AC board must be used at the NT-A and/or the NT-B position of the 7360
ISAM FX subrack. Figure 1 shows the position of the FANT-F in the ISAM system.

Fig. 1: Position of the FANT-F AC in the system

Management-A
interface
LT #0

LT #1
NT-A
(FANT-F)
NTIO
A Power unit
Uplink/Network
Interfaces

Alarm IO board

NTIO
B LT #N-1
NT-B
(FANT-F) LT #N

Management-B
interface ISAM system

3FE 53701 ACAA TQZZA Ed 02 Released 3 / 12


FANT-F AC FX NT Unit version F

5 Functional Description

Figure 2 shows the different functional blocks of the FANT-F AC.

Fig. 2: Functional Blocks of the FANT-F AC

PBA-FANT-F
FIM BIM
BITS-Interface BITS Interface
ToD and 1PPS interface REFIN REFIN ToD and 1Hz Interface
8kHz-Interface NT Reference Clock
19.44MHz-Interface REFOUT MCSD REFOUT NT ToD/1PPS
10MHz GPS Interface LT Reference Clocks
Peer NT Reference Input Clock
PNTIN Peer NT ToD/1PPS

HIPC NT-NT Communication Itf


NT Front SystemLEDs SYSLED SOI NT-NT Switch-Over Itf
SLI NT Special Lines Itf
Local Craft Interface LCMI SIO NT Serial I/O Itf
CISC SAS NT Active-Standby Itf
BSM NT Backplane (NTIO)
Serial Management Itf
LCMI Local Craft Interface
RCMI Remote Craft Interface
SAI Serial Alarm Interface

NT Alarm-Cut-Off LED ACOLED


NT Alarm-Cut-Off-Switch ACU
ACOSW
NT Front Uplink Interface #0 FUI#0 LT1 LT SerdesItf#1
LT2 LT SerdesItf#2

LT16 LT SerdesItf#16
NT Front Uplink Interface #4 FUI#4
NUTS BUI0 Backplane Uplink Itf#0
NT Front Uplink LEDs UPLED BUI1 Backplane Uplink Itf#4

BUI7 Backplane Uplink Itf#7

NNLS NT-NT LoasSharing Itf

NTIO/NTAP-Powering Itf
PSIM NT Power Supply Itf
SMAS-Powering Itf

The different functional blocks are:


• CISC:
The Centralized ISAM System Controller (CISC) Implements all On-Board
Controller (OBC) functions which accommodate a centralized Control and
Management approach of the complete ISAM shelf and provides the necessary
processing capabilities for Ethernet packets/frames forwarded to the main OBC from
the GE switching module.

3FE 53701 ACAA TQZZA Ed 02 Released 4 / 12


FX NT Unit version F FANT-F AC

• MCSD:
The Master Clock Synchronization and Distribution (MSCD) provides the following
functionality:
• System Network Timing Reference (NTR)
• Synchronization Input references from BITS/SSU, Synchronous Ethernet input link
data clocks, IEEE-1588 ordinary or boundary clock.
• Synchronization Output reference clocks towards:
- The shelf-based LT boards (backplane connections): 8 kHz.
- The internal NTR signal from the active NT board to the standby NT board in
a redundant NT board pair (backplane connection): 8 kHz.
- The external NTR daisy-chain interface (located at the NT board front): 8 kHz and
19MHz.
- The external BITS/SSU out interface (located at the NT board front):
independently configurable to 2048 kHz, E1 or DS1 signal.
• Performance for SSU / BITS input/output: compliance with ITU-T G.813 Option 1:
ETSI.
• Performance for Synchronous Ethernet (SyncE) input/output: compliance with ITU-T
G.8262 Option 1: ETSI
• NUTS:
The Network/User Transport and Switching (NUTS) provides the interface and
switching circuitry for the front and back related uplink/network interfaces to/from
the LT slots.
• PSIM:
The Power Supply Interface Module (PSIM) converts the rack power supply into all
necessary voltages as required by the used components.
• FIM:
The Frontplate Interface Module (FIM) located at the front stiffener holds the
physical interfaces (four SFP+, one 10/100/1000Base-T interface) together with a
visual port status indication. The FIM also hosts a Management Interface (CRAFT)
together with the ACO functionality.
• BIM:
The Backplane Interface Module (BIM) constitutes all the necessary control,
management, and data plane related interface inside the complete ISAM system.

3FE 53701 ACAA TQZZA Ed 02 Released 5 / 12


FANT-F AC FX NT Unit version F

6 External Interfaces

The following external interfaces are accessible via the front panel:

Communication Interfaces
5 communication interfaces are available via the front panel:
• 1 x fixed 10/100/1000BaseT port:
This port can work both in 10Mbit, 100Mbit or 1GE mode.
• 4 x 10GE SFP+ port:
This port can work both in 1 GE mode (with standard SFP optics) and in 10 GE mode
(with SFP+ optics).

Management Interfaces
The following management interfaces are available via the front panel:
• Local Craft Management interface (LCMI) (RJ45 connector)
• An Alarm Cut-Off Switch (ACOS) and LED (ACOLED)
Note: any of the five communication interfaces can also be used as management interface.
The following clock interfaces are available via the front panel:
• BITS input interface (RJ45 connector)
• BITS output interface (RJ45 connector)
• Time of Day (ToD) interface
• 10MHz GPS interface (SMA connector)
• 1pps interface (SMA connector)
• Daisy-Chain NTR clock output interface (RJ45 connector)

Local Craft Interface


Table 2 shows the signal list and connector pinning (RJ45)

Table 2: Local Craft Interface Pinning

Signal Name Description Type Pin Nr. Technology

LCMI_RI_DSR Local-Craft-Mgt-Itf “Data-Set-Ready” O 1 EIA/TIA-562

LCMI_DCD Local-Craft-Mgt-Itf “Data-Carrier-Detect” O 2 EIA/TIA-562

LCMI_DTR Local-Craft-Mgt-Itf “Data-Terminal-Ready” I 3 EIA/TIA-562

EG Electrical Ground or “Signal Ground” Ref 4 Ref

LCMI_RXD Local-Craft-Mgt-Itf related serial Receive-Data O 5 EIA/TIA-562

LCMI_TXD Local-Craft-Mgt-Itf related serial Transmit-Data I 6 EIA/TIA-562

(1 of 2)

3FE 53701 ACAA TQZZA Ed 02 Released 6 / 12


FX NT Unit version F FANT-F AC

Signal Name Description Type Pin Nr. Technology

LCMI_CTS Local-Craft-Mgt-Itf “Clear-To-Send” O 7 EIA/TIA-562

LCMI_RTS Local-Craft-Mgt-Itf “Request-To-Send” I 8 EIA/TIA-562

(2 of 2)

BITS Interface
The BITS/DC IN/OUT interfaces are mapped to two physical RJ45 connectors.

Fig. 3: RJ45 Connector


8 1

Table 3 shows the signals of the BITS-/DC IN connector.

Table 3: BITS/DC IN Signals

Signal Name Description Type RJ45 Pin

BITS-IN_T/R BITS Network Timing-Reference I 2, 3


(Tip line and Ring line are a differential pair of 120 Ω)
FG_ESD_EMC Frame Ground Ref 1, 4 & CASE

Table 4 shows the signals of the BITS-/DC OUT connector.

Table 4: BITS/DC OUT Signals

Signal Name Description Type RJ45 Pin

BITS-OUT_T/R BITS-OUT / BITS Cut-through Network Timing-Reference O 2, 3


(Tip line and Ring line are a differential pair of 120 Ω)

DC-OUT-8k_T/F Daisy-Chain 8KHz Timing Reference Output Clock O 5, 6


Differential pair 100 Ω LVPECL
DC-OUT-19K_T/F Daisy-Chain 19.44MHz Timing Reference Output Clock O 7, 8
Differential Pair 100 Ω, LVPECL

FG_ESD_EMC Frame Ground Ref 1,4 & CASE

3FE 53701 ACAA TQZZA Ed 02 Released 7 / 12


FANT-F AC FX NT Unit version F

ToD and 1Hz Validation Pulse Input Interface


The FANT-F provides a Time of Day (ToD) port on its frontplate. This interface consists
of differential ToD and 1PPS signals (RS-422 technology), mapped on a RJ45 connector.
Table 5 shows the signals of the ToD interface.

Table 5: TOD/1PPS-Interface Signal-List of the Frontplate

Signals Description Type RJ45 Pin

ToD_UART_T/F ToD UART TX, PTP Master mode (differential pair, 100 ohm) O 8, 7

ToD UART RX, PTP Slave mode (differential pair, 100 ohm) I

ToD_1PPS_T/F 1PPS output, PTP Master mode (differential pair, 100 ohm) O 6, 3

1PPS input, PTP Slave mode (differential pair, 100 ohm) I

EG Electrical Ground REF 4, 5

FG Frame Ground REF CASE


NC Not Connected - 1, 2

1PPS interface on the SMA connector


Table 6 shows the signals of the 1PPS interface on the SMA connector.

Table 6: 1PPS Interface on the SMA connector: Signal-List

Signals Description Type Technology

1PPS-TTL 1PPS output, PTP Slave mode (single-ended, 50 ohm) O TTL


1PPS input, PTP Master mode (single-ended, 50 ohm) I TTL

Shield Frame ground I Ref.

10MHz GPS interface on the SMA connector


Table 7 shows the signals of the 10MHz GPS interface on the SMA connector.

Table 7: 10MHz GPS interface on the SMA connector: Signal-List

Signals Description Type Technology

10M_GPS-IN 10 MHz GPS Timing Reference (sinewave, 50 ohm, I 2 to 5 Vpp


transformer coupled)

Shield Frame ground I Ref.

3FE 53701 ACAA TQZZA Ed 02 Released 8 / 12


FX NT Unit version F FANT-F AC

7 Alarm Control Unit

The Alarm Control Unit (ACU) provides:


• a central point for internal (= subrack-related) alarm collection.
• a central point for external (= CO-related) alarm collection and control.
• the necessary circuitry for rack alarm control and visualization.
• an Alarm Cut Off (ACO) capability to the subrack.

The following ACU functionality is provided:


• Fan unit alarm interface. The alarm interface uses the GFC as an alarm handle. The
FANT-F reads and writes alarms through I2C and SPI interfaces.
• Central Office alarm interface
• Circuit breaker alarm
• Door alarm
• Subrack alarm lamp interface
• Miscellaneous output alarm

These ACU interfaces can be found on the backplane of the subrack, for more
information refer to the 7360 ISAM FX Hardware Installation Manual.

3FE 53701 ACAA TQZZA Ed 02 Released 9 / 12


FANT-F AC FX NT Unit version F

8 Physical Description

Figure 4 shows the side and front view of the FANT-F.

Fig. 4: View of the FANT-F AC

LEDs

SFP cages

1PPS Signal

10MHz Signal

Front Uplink Interface

CRAFT Interface

Time of Day

BITS in

BITS out

3FE 53701 ACAA TQZZA Ed 02 Released 10 / 12


FX NT Unit version F FANT-F AC

Dimensions:
The dimensions of the FANT-F AC are:
• Board height: 405 mm
• Width: 30 mm
• Depth: 205/225 mm

System Status LEDS


Figure 5 shows the system status LEDs of the FANT-F AC.
Fig. 5: System Status LEDs

ACO

ALM PWR

ACO A/S

FSM2 FSM1

FSM4 FSM3

Table 8 gives the definitions of the system status LEDS on the FANT-F.

Table 8: System Status LED Definition

Port Description

PWR • Green - Power present


• Off - No power

A/S • Green - Active


• Off - Stand-by

ALM • Red - Alarm condition exists


• Off - No alarm condition exists

ACO • Green - Alarm has been cut off


• Off - No alarm cut off

FSM1 • Link/Activity status (module 1)


FSM2 • Link/Activity status (module 2)
FSM3 • Link/Activity status (module 3)
FSM4 • Link/Activity status (module 4)

Alarm Cut Off


The FANT-F AC is equipped with an Alarm Cut Off switch and an Alarm Cut Off
indication LED (refer to Figure 5).

3FE 53701 ACAA TQZZA Ed 02 Released 11 / 12


FANT-F AC FX NT Unit version F

9 Power Supply

The FANT-F is compatible with -48 Vdc nominal and -60 Vdc nominal power supply
systems.
Note: Country dependent tolerances exist regarding the nominal battery voltage values.

3FE 53701 ACAA TQZZA Ed 02 Released 12 / 12

Вам также может понравиться