NIM : 1641150013
Kelas : SKL 2B
Diketahui :
Grup 1 S = 600 kVA
Faktor Koreksi
Grup 2 S = 200 kVA
Suhu 50 ̊ = 0,71
Grup 3 S = 400 kVA
Penataan = 0,96 (trifoil)
Grup 4 S = 300 kVA
FK = 0,71 x 0,96
Grup 5 S = 100 kVA
= 0,681
G.Total S = 1600 kVA
Tegangan = 380 V
Ditanya :
Group 1
S = √3 . V. In
S 600 600
In = = = = 0,911 kA ≈ 911 A
√3.V √3 . 380 658,17
IKHA = 1,25 x In
Ipmt = 1,15 x In
Group 2
S = √3 . V. In
S 200 200
In = = = = 0,303 kA ≈ 303 A
√3.V √3 . 380 658,17
IKHA = 1,25 x In
Group 3
S = √3 . V. In
S 400 600
In = = = = 0,607 kA ≈ 607 A
√3.V √3 . 380 658,17
IKHA = 1,25 x In
Ipmt = 1,15 x In
Group 4
S = √3 . V. In
S 300 300
In = = = = 0,455 kA ≈ 455 A
√3.V √3 . 380 658,17
IKHA = 1,25 x In
Ipmt = 1,15 x In
Group 5
S = √3 . V. In
S 100 100
In = = = = 0,152 kA ≈ 152 A
√3.V √3 . 380 658,17
IKHA = 1,25 x In
Ipmt = 1,15 x In
Stot = √3 . V. In
Busbar = 1,25 x In
IKHA 1519,36
IFK = = = 2231,07 A
FK 0,681
2231,07
Penentuan kabel = = 743,6 A (825 A, katalog Supreme)
3
Jadi 825 A x 3 = 2475 A (katalog supreme LV NYY 400 mm2 x 3 x 3)
Ipmt = 1,15 x In
Stot = √3 . V. In
Busbar = 1,25 x In
IKHA 1519,36
IFK = = = 2231,07 A
FK 0,681
2231,07
Penentuan kabel = = 743,6 A (825 A, katalog Supreme)
3
Jadi 825 A x 3 = 2475 A (katalog supreme LV NYY 400 mm2 x 3 x 3)
Stot = √3 . V. Itot
Busbar = 1,25 x In
IKHA 3038,72
IFK = = = 4462,14 A
FK 0,681
4462,14
Penentuan kabel = = 743,69 A (825 A, katalog Supreme)
6
Jadi 825 A x 6 = 4950 A (katalog supreme LV NYY 400 mm2 x 3 x 6)
Ipmt ATS
= 1,2 x Itot
Pemilihan Trafo
Stot = √3 . V. Itot
Stot 1600
Itot = = = 46,16 A
√3.V √3 . 20
= 1,25 x Itot
IKHA 57,72
IFK = = = 84,75 A
FK 0,681
Katalog Supreme Medium Voltage Trefoil Almunium (AL) 125 A (3x1x25mm2)
Penentuan Netral
Group 1 = 240 : 2 = 120 mm2
Group 2 = 50 : 2 = 25 mm2
Group 3 = 120 : 2 = 60 mm2
Group 4 = 95 : 2 = 47,5 mm2
Group 5 = 16 : 2 = 8 mm2
IKHA PLN = 400 : 2 = 200 mm2
IKHA Genset = 400 : 2 = 200 mm2
IKHA PLN - Genset = 400 : 2 = 200 mm2