Вы находитесь на странице: 1из 59

RAM

STANDARD FORMS Revision: 01


Effective Date: 01.12.13 Page: 1

FN005 - ROAD STRUCTURE AND FACILITY INSPECTION REPORT – A SUMMARY

Road Structure and Facility Inspection Report – A Summary

Bridge ID: 3 1 9 0 6 - M - 0 0 0 2 0

Bridge Location: Loc.120 : Jurong Pier Rd/Jln Buroh/ (Jurong Pier Flyover)

Date of Inspection: 1 3 1 0 1 7 Inspection: M P P S

Date of Last Inspection:

Access to Site: Walking Tidal: No

Report from Inspector


Name of Organization: Novaars International Pte. Ltd.
Contract Number: TR271 (West Sector) 1 (summarize results of inspection)
1. Cracks on manhole at carriageway. (Photo 2b)
2. Water logging and drain chocked. (Photo 4)
3. Cracks on carriageway. (Photos 5a,b; 76)
4. Vertical crack on parapet. (Photos 7a,b; 14b; 16a,b; 30a,b; 35a,b; 40; 52; 55a,b;
61a,b;66a,b)
5. Bottom grout cracked at lamp post base plate. (Photos 8; 49a~c)
6. Bottom grout cracked at railing base plate. (Photos 9a~d; 34a~d; 62a~d; 68a,b)
7. Horizantal railing member damaged. (Photo 10)
8. Overgrown plants cover the railing member. (Photos 11a,b; 36; 56a,b)
9. Corrosion on bolts at guard rail base plate. (Photos 13b; 39; 51b; 71)
10. Map cracks on parapet. (Photo 14a)
11. Horizantal railing member bent. (Photo 19)
12. Dislodged sign clamp. (Photos 20b; 41b; 59b)
13. Map cracks on bracing. (Photos 21; 29)
14. Vertical cracks on bracing. (Photos 22; 63a,b)
15. Exposed aggregate on the premix. (Photos 23a,b)
16. Missing bolts at railing. (Photos 11b; 25; 58a,b)
17. Missing bottom grout at railing base plate. (Photos 26a,b; 57; 77a,b)
18. Blow holes with stains on bracing. (Photo 28)
19. Dislodged speed limit sign at LP-F18. (Photo 31)
20. Sign of water logging at carriageway. (Photo 32)
21. Crack with stains on bracing. (Photo 33)
22. Drain chocked. (Photos 42a,b; 79a,b)
23. Broken kerb. (Photos 43a~c)
24. Missing surface finish at parapet. (Photos 45; 47; 74a,b)
25. Map cracks on carriageway. (Photo 46a)
26. Transverse cracks on carriageway. (Photos 46b; 75)
27. Potholes on premix at carriageway. (Photo 48)
28. Crack on expansion joint noising. (Photo 54)
29. Stains on bracing. (Photos 60; 104)
30. Loose bolt at railing. (Photo 64)
31. Spalling of surface finish beside the parapet joint. (Photo 67)
32. Crack and missing bolts at expansion joint. (Photos 70a~c)
33. Missing sealant at parapet joint. (Photo 73)
34. Vertical cracks on approach structure. (Photos 81a,b; 82)
35. Stains on abutment. (Photos 84; 109)
36. Broken down pipe clamp. (Photo 85)
37. Surface drain chocked by debris. (Photos 88; 110a,b)
38. Vertical crack on abutment. (Photo 89)
39. Water leakage from the down pipe joint. (Photo 90)
40. Vertical crack on approach structure. (Photos 91a,b; 115a,b; 117a,b; 119)
41. Plant growth at approach structure. (Photo 92)
42. Effloresence on beam soffit. (Photo 93)
43. Plant growth at parapet. (Photos 95a,b)
44. Effloresence on cantilever slab soffit. (Photo 97)
45. Cracks with stains on crosshead. (Photo 98)
46. Corrosion on sign base plate. (Photo 101)
47. Cracks with stains on crosshead. (Photos 102a,b)
48. Dislodged down pipe section/joint. (Photo 105)
49. Spalling of surface finish on approach structure. (Photos 114a,b)
50. Crack with effloresence on approach structure. (Photo 116)
51. Water leakage from the joint at cantilever slab soffit. (Photo 118)

Inspected by: Periyasamy Ganesan

Number of pages in report: 50


(including sketches, notes, photos etc)

Prepared by: S.S.Thit/ Engineer/ Novaars International Pte. Ltd. Date : 20.oct.2017
(Name/Designation/Company)

Vetted by: Sangeeta Chhabra/ Sr. Manager/ Novaars International Pte. Ltd. Date: 23.oct.2017
(Name/Designation/Company)

Accepted by: Yogesh Chhabra/ P I/ Novaars International Pte. Ltd. Date: 27.oct.2017
(Name/Designation/Company)

For LTA Use:


INS SH E M/DM
Date Date Date Date

* Delete where necessary

M denotes Maintenance Inspection


P denotes Principal Inspection
S denotes Special Inspection
MAINTENANCE INSPECTION SUMMARY

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Photographic Index: [Sketch of bridge and photographic locations]


Summary of Defects:
No Description of Defect: Extent Photo Ref For LTA use

1 Cracks on manhole at carriageway. 1mx1m area 2b

2 Water logging and drain chocked. 4


5 a) 3mx6m area,
b) 1mx10m area,
76) 5~10mm
wide & 1mx30m
3 Cracks on carriageway. area 5a,b; 76

7a,b) 0.4mm wide


& 1m long -
typical, 14 b)
0.4mm wide & 1m
long - 0.3~0.5m
interval - 10 nos,
16a,b;30a,b;35a,b;4
0;52;55a,b;61a,b;6
6a,b) 0.3mm wide
7a,b; 14b; 16a,b;
& 1m long - 1m 30a,b; 35a,b; 40; 52;
4 Vertical crack on parapet. interval - typical 55a,b; 61a,b;66a,b
Bottom grout cracked at lamp post
5 base plate. Typical 8; 49a~c
Bottom grout cracked at railing base
plate. 9a~d; 34a~d;
6 Typical 62a~d; 68a,b

7 Horizantal railing member damaged. 1m long 10

Overgrown plants cover the railing


8 member. Typical 11a,b; 36; 56a,b
Corrosion on bolts at guard rail base
9 plate. Typical
0.3mm wide 13b; 39; 51b; 71
& 1mx20m
10 Map cracks on parapet. area, 14a

11 Horizantal railing member bent. 0.5m long 19

20b) 2 nos,
12 Dislodged sign clamp. 41b;59b) 1 no 20b; 41b; 59b
21) 0.5mm wide
& 1mx3m area,
13 Map cracks on bracing. 29) 2mx4m area 21; 29

22) 0.4~1mm
wide & 0.5~1m
long - 5 nos,
63a,b) 0.5mm
wide & 1m long -
14 Vertical cracks on bracing. 3 nos 22; 63a,b
a) 1mx5m
area, b)
15 Exposed aggregate on the premix. 1mx2m area 23a,b
11b) 1 no; 25)
16 nos; 58a,b)
16 Missing bolts at railing. 1 no - each 11b; 25; 58a,b

Missing bottom grout at railing base


17 plate. Typical 26a,b; 57; 77a,b
1mx2m area-
18 Blow holes with stains on bracing. 2 nos 28

19 Dislodged speed limit sign at LP-F18 1 no 31

20 Sign of water logging at carriageway. 32

21 Crack with stains on bracing. 1mx1m area 33

22 Drain chocked. Typical 42a,b; 79a,b

23 Broken kerb. 3 nos 43a~c


45) 0.5mx0.5m
area, 47)
0.2mx20m area -
typical, 74a)
0.2mx30m area,
b) 0.3mx10m
24 Missing surface finish at parapet. area 45; 47; 74a,b

7mm wide &


25 Map cracks on carriageway. 1mx30m area, 46a
46b) 7mm wide
& 5m long, 75)
10mm wide &
26 Transverse cracks on carriageway. 5m long 46b; 75
0.1m x 0.3m
27 Potholes on premix at carriageway. area 48

28 Crack on expansion joint noising. 0.2mx1m area 54


60) 1mx2m area-
typical,104)
29 Stains on bracing. 1mx4m area 60; 104

30 Loose bolt at railing. 1 no 64


Spalling of surface finish beside the 50mmx0.1m
31 parapet joint. area - 1
Crack 67
Crack and missing bolts at expansion plate, bolt - 4
32 joint. nos 70a~c
33 Missing sealant at parapet joint. 1 no 73
81a) 0.4mm
wide & 1m long -
2 nos, b) 0.4mm
wide & 2m long -
typical, 82)
0.4mm wide &
34 Vertical cracks on approach structure. 2m long - 4 nos 81a,b; 82
84)2mx3m
area, 109)
3mx3m area- 2
35 Stains on abutment. nos 84; 109
36 Broken down pipe clamp. 3 nos 85

37 Surface drain chocked by debris. Typical 88; 110a,b


0.3mm wide &
38 Vertical crack on abutment. 2m long - 2 nos 89
Water leakage from the down pipe
39 joint. 90
91a,b) 0.3mm wide
& 0.7~3m long -
typical,115a,b;119)
0.2~0.3mm wide &
1~2m long
(typical),117a,b)0.4
~0.5mm wide &
1~2m long 91a,b; 115a,b;
40 Vertical crack on approach structure. (typical) 117a,b; 119
41 Plant growth at approach structure. 92
3mx3m area-
42 Effloresence on beam soffit. typical 93
43 Plant growth at parapet. 95a,b
44 Effloresence on cantilever slab soffit. 1.5mx6m area 97
1.5mx1.5m
45 Cracks with stains on crosshead. area 98
46 Corrosion on sign base plate. 2 nos 101
1.5mx1.5m
47 Cracks with stains on crosshead. area 102a,b
48 Dislodged down pipe section/joint. 1 no 105
Spalling of surface finish on approach 0.1mx0.1m
49 structure. area - typical 114a,b
Crack with effloresence on approach 0.2mx0.5m
50 structure. area 116
Water leakage from the joint at
51 cantilever slab soffit. 118
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Photo Ref:
Element:

Extent:

For LTA use:

Photo Ref: 1
Element: Flyover

Type of Defect: General


view of flyover.

Extent:

For LTA use:

Photo Ref: 2a,b


a
Element: Carriageway

Type of Defect: a) General


view, b) Cracks on manhole
at carriageway.
b

Extent: b) 1mx1m area

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


For LTANo: TR271 (West Sector)
use:
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Photo Ref: 3
Element: Directional Sign

Type of Defect: General


view of directional sign.

Extent:

For LTA use:

Photo Ref: 4
Element: Drainage

Type of Defect: Water


logging and drain chocked.

Extent:

For LTA use:

Photo Ref: 5a,b


b Element: Carriageway

Type of Defect: Cracks on


a
carriageway.

Extent: a) 3mx6m area, b)


1mx10m area

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
For LTA use:

Photo Ref: 6a,b


a
Element: Parapet

Type of Defect: General


view of parapet.

Extent:

For LTA use:

Photo Ref: 7a,b


a
Element: Parapet

Type of Defect: Vertical


crack on parapet.

Extent: 0.4mm wide & 1m


long - typical

For LTA use:

Photo Ref: 8
Element: Lamp Post

Type of Defect: Bottom


grout cracked at lamp post
base plate.

Extent: Typical
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Extent: No: TR271 (West Sector)
Typical

For LTA use:

Photo Ref: 9a~d


a b Element: Railing

Type of Defect: Bottom


grout cracked at railing base
plate.

c d

Extent: Typical

For LTA use:

Photo Ref: 10
Element: Railing

Type of Defect: Horizantal


railing member damaged.

Extent: 1m long

For LTA use:

Photo Ref: 11a,b


a Element: Railing

Type of Defect: Overgrown


plants cover the railing
member, b)Missing bolt at
railing.
b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: Typical, b) 1 no

For LTA use:

Photo Ref: 12
Element: Superman Sign

Type of Defect: General


view of superman sign.

Extent:

For LTA use:

Photo Ref: 13a,b


a
Element: Guard Rail

Type of Defect: a) General


view, b) Corrosion on bolts
at guard rail base plate.
b

Extent: Typical

For LTA use:

Photo Ref: 14a,b


a
Element: Parapet

Type of Defect: a) Map


cracks, b) Vertical cracks on
parapet.
b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Type of Inspection:
Date of Defect: a) Map
13.10.2017
cracks, b) Vertical cracks on
parapet.
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: a) 0.3mm wide & 1mx20m


area, b) 0.4mm wide & 1m long -
0.3~0.5m interval - 10 nos

For LTA use:

Photo Ref: 15
Element: Expansion Joint

Type of Defect: General


view of expansion joint.

Extent:

For LTA use:

Photo Ref: 16a,b


a
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 17
Element: Carriageway

Type of Defect: General


view of carriageway.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017
Type of Defect: General
view of carriageway.
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent:

For LTA use:

Photo Ref: 18
Element: Lamp Post

Type of Defect: General


view of lamp post LPF30

Extent:

For LTA use:

Photo Ref: 19
Element: Railing

Type of Defect: Horizantal


railing member bent.

Extent: 0.5m long

For LTA use:

Photo Ref: 20a,b


a
Element: Sign

Type of Defect: a) General


view, b) Dislodged sign
clamp.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Type ofNo: TR271a)(West
Defect: Sector)
General
view, b) Dislodged sign
clamp.
b

Extent: b) 2 nos

For LTA use:

Photo Ref: 21
Element: Bracing

Type of Defect: Map cracks


on bracing.

Extent: 0.5mm wide &


1mx3m area

For LTA use:

Photo Ref: 22
Element: Bracing

Type of Defect: Vertical


cracks on bracing.

Extent: 0.4~1mm wide &


0.5~1m long - 5 nos

For LTA use:

Photo Ref: 23a,b


a
Element: Carriageway
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Type of Defect: Exposed


aggregate on the premix.

Extent: a) 1mx5m area, b)


1mx2m area

For LTA use:

Photo Ref: 24a,b


a Element: Bracing

Type of Defect: General


view of overhead bracing.

Extent:

For LTA use:

Photo Ref: 25
Element: Railing

Type of Defect: Missing


bolts at railing.

Extent: 16 nos

For LTA use:

Photo Ref: 26a,b


a
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

a
Element: Railing

Type of Defect: Missing


bottom grout at railing base
plate.
b

Extent: Typical

For LTA use:

Photo Ref: 27
Element: Drainage

Type of Defect: General


view of drain covers.

Extent:

For LTA use:

Photo Ref: 28
Element: Bracing

Type of Defect: Blow holes


with stains on bracing.

Extent: 1mx2m area- 2 nos

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


For LTANo: TR271 (West Sector)
use:

Photo Ref: 29
Element: Bracing

Type of Defect: Map cracks


on bracing.

Extent: 2mx4m area

For LTA use:

Photo Ref: 30a,b


a Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 31
Element: Sign

Type of Defect: Dislodged


speed limit sign at LP-F18.

Extent: 1 no
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

For LTA use:

Photo Ref: 32
Element: Carriageway

Type of Defect: Sign of


water logging at
carriageway.

Extent:

For LTA use:

Photo Ref: 33
Element: Bracing

Type of Defect: Crack with


stains on bracing.

Extent: 1mx1m area

For LTA use:

Photo Ref: 34a~d


a b Element: Railing

Type of Defect: Bottom


grout cracked at railing base
plate.

c d

Extent: Typical
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
Extent: Typical

For LTA use:

Photo Ref: 35a,b


a
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 36
Element: Railing

Type of Defect: Overgrown


plants cover the railing
member.

Extent: Typical

For LTA use:

Photo Ref: 37
Element: Expansion Joint

Type of Defect: General


view of expansion joint.
Defect Photographs
Type of Defect: General
Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/ view of expansion joint.
(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent:

For LTA use:

Photo Ref: 38
Element: Carriageway

Type of Defect: General


view of carriageway.

Extent:

For LTA use:

Photo Ref: 39
Element:Guard Rail

Type of Defect: Corrosion


on bolts at guard rail base
plates.

Extent: Typical

For LTA use:

Photo Ref: 40
Element: Parapet

Type of Defect: Vertical


cracks on parapet.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Type of Inspection:
Date of Defect: Vertical
13.10.2017
cracks on parapet.
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 41a,b


a Element: Sign

b Type of Defect: a) General


view, b) Dislodged sign
clamp.

Extent: b) 1 no

For LTA use:

Photo Ref: 42a,b


a
Element: Drainage

Type of Defect: Drain


chocked.

Extent: Typical

For LTA use:

Photo Ref: 43a~c


a b
Element: Kerb

Type of Defect: Broken


c kerb.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017
Type of Defect: Broken
Consultants: Novaars International Pte. Ltd. Contract
kerb. No: TR271 (West Sector)
c

Extent: 3 nos

For LTA use:

Photo Ref: 44
Element: Overview

Type of Defect: General


view of flyover.

Extent:

For LTA use:

Photo Ref: 45
Element: Parapet

Type of Defect: Missing


surface finish at parapet.

Extent: 0.5mx0.5m area

For LTA use:

Photo Ref: 46a,b


b Element: Carriageway

Type of Defect: a) Map


a cracks, b) Transverse cracks
on carriageway.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
Type of Defect: a) Map
a cracks, b) Transverse cracks
on carriageway.

Extent: a) 7mm wide & 1mx30m


area, b) 7mm wide & 5m long

For LTA use:

Photo Ref: 47
Element: Parapet

Type of Defect: Missing


surface finish at parapet.

Extent: 0.2mx20m area -


typical

For LTA use:

Photo Ref: 48
Element: Carriageway

Type of Defect: Potholes on


premix at carriageway.

Extent: 0.1m x 0.3m area

For LTA use:

Photo Ref: 49a~c


a b Element: Lamp Post
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
a b
Element: Lamp Post

Type of Defect: Bottom


grout cracked at lamp post
base plate.

Extent: Typical

For LTA use:

Photo Ref: 50
Element: Superman Sign

Type of Defect: General


view of superman sign.

Extent:

For LTA use:

Photo Ref: 51a,b


a Element: Guard Rail

Type of Defect: a) General


view, b) Corrosion on bolts
at guard rail base plate.
b

Extent: Typical

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Photo Ref: 52
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 53
Element: Expansion Joint

Type of Defect: General


view of expansion joint.

Extent:

For LTA use:

Photo Ref: 54
Element: Expansion Joint

Type of Defect: Crack on


expansion joint noising.

Extent: 0.2mx1m area

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
For LTA use:

Photo Ref: 55a,b


a
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 56a,b


a
Element: Railing

Type of Defect: Overgrown


plants cover the railing
member.
b

Extent: Typical

For LTA use:

Photo Ref: 57
Element: Railing

Type of Defect: Missing


bottom grout at railing base
plate.

Extent: Typical
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Extent: No: TR271 (West Sector)
Typical

For LTA use:

Photo Ref: 58a,b


a
Element: Railing

Type of Defect: Missing


bolts at railing.

Extent: 1 no - each

For LTA use:

Photo Ref: 59a,b


a
Element: Sign

Type of Defect: a) General


view, b) Dislodged sign
clamp.
b

Extent: b) 1 no

For LTA use:

Photo Ref: 60
Element: Bracing

Type of Defect: Stains on


bracing.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 1mx2m area- typical

For LTA use:

Photo Ref: 61a,b


a
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 62a~d


a b Element: Railing

Type of Defect: Bottom


grout cracked at railing base
plate.

c d

Extent: Typical

For LTA use:

Photo Ref: 63a,b


a Element: Bracing

Type of Defect: Vertical


cracks on bracing.

b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/ Type of Defect: Vertical
(Jurong Pier Flyover) cracks
Date ofon bracing. 13.10.2017
Inspection:

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 0.5mm wide & 1m


long - 3 nos

For LTA use:

Photo Ref: 64
Element: Railing

Type of Defect: Loose bolt


at railing.

Extent: 1 no

For LTA use:

Photo Ref: 65a,b


a Element: Sign

Type of Defect: a) General


view, b) sign clamp.

Extent: Typical

For LTA use:

Photo Ref: 66a,b


a
Element: Parapet

Type of Defect: Vertical


cracks on parapet.

b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017
Type of Defect: Vertical
cracks on parapet.
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 0.3mm wide & 1m


long - 1m interval - typical

For LTA use:

Photo Ref: 67
Element: Parapet

Type of Defect: Spalling of


surface finish beside the
parapet joint.

Extent: 50mmx0.1m area

For LTA use:

Photo Ref: 68a,b


a
Element: Railing

Type of Defect: Bottom


grout cracked at railing base
plate.
b

Extent: Typical

For LTA use:

Photo Ref: 69
Element: Expansion Joint

Type of Defect: General


view of expansion joint.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Type ofNo: TR271General
Defect: (West Sector)
view of expansion joint.

Extent:

For LTA use:

Photo Ref: 70a~c


a b
Element: Expansion Joint

Type of Defect: Crack and


missing bolts at expansion
joint.

Extent: Crack - 1 plate, bolt


- 4 nos

For LTA use:

Photo Ref: 71
Element: Guard Rail

Type of Defect: Corrosion


on bolts at guard rail base
plates.

Extent: Typical

For LTA use:

Photo Ref: 72
Element: Parapet
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Type of Defect: General


view of parapet.

Extent:

For LTA use:

Photo Ref: 73
Element: Parapet

Type of Defect: Missing


sealant at parapet joint.

Extent: 1 no

For LTA use:

Photo Ref: 74a,b


a Element: Parapet

Type of Defect: Missing


b surface finish at parapet.

Extent: a) 0.2mx30m area,


b) 0.3mx10m area

For LTA use:

Photo Ref: 75
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Element: Carriageway

Type of Defect: Transverse


crack on carriageway.

Extent: 10mm wide & 5m


long

For LTA use:

Photo Ref: 76
Element: Carriageway

Type of Defect: Cracks on


carriageway.

Extent: 5~10mm wide &


1mx30m area

For LTA use:

Photo Ref: 77a,b


a Element: Railing

Type of Defect: Missing


bottom grout at railing base
plate.
b

Extent: Typical

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


For LTANo: TR271 (West Sector)
use:

Photo Ref: 78
Element: Carriageway

Type of Defect: General


view of carriageway.

Extent:

For LTA use:

Photo Ref: 79a,b


a b
Element: Drainage

Type of Defect: Drain


chocked.

Extent: Typical

For LTA use:

Photo Ref: 80a,b


a Element: Approach Structure

Type of Defect: General


view of approach structure.

Extent:
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

For LTA use:

Photo Ref: 81a,b


b Element: Approach Structure

Type of Defect: Vertical


a
cracks on approach
structure.

Extent: a) 0.4mm wide & 1m long - 2


nos, b) 0.4mm wide & 2m long -
typical

For LTA use:

Photo Ref: 82
Element: Approach Structure

Type of Defect: Vertical


cracks on approach
structure.

Extent: 0.4mm wide & 2m


long - 4 nos

For LTA use:

Photo Ref: 83a,b


a Element: Approach Structure

Type of Defect: General


view of approach structure.

Extent:
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
Extent:

For LTA use:

Photo Ref: 84
Element: Abutment

Type of Defect: Stains on


abutment.

Extent: 2mx3m area

For LTA use:

Photo Ref: 85
Element: Down Pipe

Type of Defect: Broken


down pipe clamp.

Extent: 3 nos

For LTA use:

Photo Ref: 86a,b


a
Element: Bearing

Type of Defect: General


view of bearing.

b
Defect Photographs
Type of Defect: General
Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/ view of bearing.
(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent:

For LTA use:

Photo Ref: 87a,b


a
Element: Bearing

Type of Defect: General


view of bearing.

Extent:

For LTA use:

Photo Ref: 88
Element: Drainage

Type of Defect: Surface


drain chocked by debris.

Extent: Typical

For LTA use:

Photo Ref: 89
Element: Abutment

Type of Defect: Vertical


crack on abutment.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Type of Inspection:
Date of Defect: Vertical
13.10.2017
crack on abutment.
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 0.3mm wide & 2m


long - 2 nos

For LTA use:

Photo Ref: 90
Element: Down Pipe

Type of Defect: Water


leakage from the down pipe
joint.

Extent:

For LTA use:

Photo Ref: 91a,b


a Element: Approach Structure

Type of Defect: Vertical


crack on approach structure.

Extent: 0.3mm wide &


0.7~3m long - typical

For LTA use:

Photo Ref: 92
Element: Approach Structure

Type of Defect: Plant


growth at approach
structure.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017
Type of Defect: Plant
Consultants: Novaars International Pte. Ltd. Contract
growth No: TR271 (West Sector)
at approach
structure.

Extent:

For LTA use:

Photo Ref: 93
Element: Beam

Type of Defect:
Effloresence on beam soffit.

Extent: 3mx3m area- typical

For LTA use:

Photo Ref: 94a,b


a
Element: Beam

Type of Defect: General


view of beam soffit.

Extent:

For LTA use:

Photo Ref: 95a,b


a
Element: Parapet

Type of Defect: Plant


growth at parapet.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
Type of Defect: Plant
growth at parapet.

Extent:

For LTA use:

Photo Ref: 96a,b


a b Element: Column

Type of Defect: General


view of column.

Extent:

For LTA use:

Photo Ref: 97
Element: Cantilever Slab

Type of Defect:
Effloresence on cantilever
slab soffit.

Extent: 1.5mx6m area

For LTA use:

Photo Ref: 98
Element: Crosshead
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
Element: Crosshead

Type of Defect: Cracks with


stains on crosshead.

Extent: 1.5mx1.5m area

For LTA use:

Photo Ref: 99a,b


a
Element: Guard Rail

Type of Defect: General


view of guard rail.

Extent:

For LTA use:

Photo Ref: 100


Element: Bridge Soffit

Type of Defect: General


view of bridge soffit.

Extent:

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Photo Ref: 101


Element: Sign

Type of Defect: Corrosion


on sign base plate.

Extent: 2 nos

For LTA use:

Photo Ref: 102a,b


a
Element: Crosshead

Type of Defect: Cracks with


stains on crosshead.

Extent: 1.5mx1.5m area

For LTA use:

Photo Ref: 103


Element: Column; Crosshead

Type of Defect: General


view of columns &
crosshead.

Extent:

For LTA use:


Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
For LTA use:

Photo Ref: 104


Element: Bracing

Type of Defect: Stains on


base of bracing.

Extent: 1mx4m area

For LTA use:

Photo Ref: 105


Element: Down Pipe

Type of Defect: Dislodged


down pipe section/joint.

Extent: 1 no

For LTA use:

Photo Ref: 106a,b


a
Element: Beam

Type of Defect: General


view of beam soffit.

Extent:
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Extent: No: TR271 (West Sector)

For LTA use:

Photo Ref: 107a,b


a b
Element: Column

Type of Defect: General


view of column.

Extent:

For LTA use:

Photo Ref: 108


Element: Abutment

Type of Defect: General


view of abutment.

Extent:

For LTA use:

Photo Ref: 109


Element: Abutment

Type of Defect: Stains on


abutment.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent: 3mx3m area- 2 nos

For LTA use:

Photo Ref: 110a,b


a b
Element: Drainage

Type of Defect: Surface


drain chocked by debris.

Extent: Typical

For LTA use:

Photo Ref: 111a,b


a
Element: Bearing

Type of Defect: General


view of bearing.

Extent:

For LTA use:

Photo Ref: 112a,b


a
Element: Bearing

Type of Defect: General


view of bearing.

b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/ Type of Defect: General
(Jurong Pier Flyover) view of Inspection:
Date of bearing. 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)

Extent:

For LTA use:

Photo Ref: 113a,b


a
Element: Approach Structure

Type of Defect: General


view of approach structure.

Extent:

For LTA use:

Photo Ref: 114a,b


a
Element: Approach Structure

Type of Defect: Spalling of


surface finish on approach
structure.
b

Extent: 0.1mx0.1m area -


typical

For LTA use:

Photo Ref: 115a,b


a
Element: Approach Structure

Type of Defect: Vertical


cracks on approach
structure.

b
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017
Type of Defect: Vertical
cracks on approach
Consultants: Novaars International Pte. Ltd. Contract No: TR271 (West Sector)
structure.
b

Extent: 0.2~0.3mm wide &


1~2m long (typical)

For LTA use:

Photo Ref: 116


Element: Approach Structure

Type of Defect: Crack with


effloresence on approach
structure.

Extent: 0.2mx0.5m area

For LTA use:

Photo Ref: 117a,b


a
Element: Approach Structure

Type of Defect: Vertical


cracks on approach
structure.
b

Extent: 0.4~0.5mm wide &


1~2m long (typical)

For LTA use:

Photo Ref: 118


Element: Cantilever Slab

Type of Defect: Water


leakage from the joint at
cantilever slab soffit.
Defect Photographs

Bridge Location/Name: Loc.120 : Jurong Pier Rd/Jln Buroh/


(Jurong Pier Flyover) Date of Inspection: 13.10.2017

Consultants: Novaars International Pte. Ltd. Contract


Type ofNo: TR271Water
Defect: (West Sector)
leakage from the joint at
cantilever slab soffit.

Extent:

For LTA use:

Photo Ref: 119


Element: Approach Structure

Type of Defect: Vertical


cracks on approach
structure.

Extent: 0.2~0.3mm wide &


1~2m long (typical)

For LTA use:


(West Sector)