Академический Документы
Профессиональный Документы
Культура Документы
1.1.1 Update …
Are you using already the NRT-V application and do you want to update to a newer version, please remove the current
version first from your computer before adding the new version.
1.1.2 ... from hard drive
Browse into the subdirectory NRT_V and call SETUP.EXE. The rest of the installation is self-explanatory.
Release 2.1
1.2 Bugfixes since 2.02
Several bugfixes in the record function.
1.3 Enhancements since 2.01
CVI Runtime will be installed in the NRT directory.
Release 2.01
1.4 Bugfixes since 2.00
Bugfixes in NRTZUpdate.exe, new version 2.68
No more re-enabling [Execute] button after Update
Start searching COM port with an eventually previously saved one
Fixed problems in recognition of sensor on different PC and/or with different USB/RS232 adapters
fixed re-entrance problem in serial receiver
Bugfix in installation process: Missing icons in start menu fixed
Release 2.0
1.5 Enhancements since 1.72
Change in firmware update of power sensor software. The update software is a separately installed tool
NRTZUpdate.exe, not longer integrated in the Virtual NRT. It is strongly recommended to use
NRTZUpdate.exe first before running “Virtual NRT”, otherwise the update may fail. In this case please
reboot your PC and try the update again.
Previous versions of NRT-V provided a function to update the firmware of the sensor. In certain combinations of operating system and interface
port this led to problems with unfinishedor not starting update procedures. Therefore we decided to separate the firmware update function from
the measurement program.
If you want to perform a firmware update please use the program NRTZUpdate.exe. This program should not be used if you already had
activated the NRT-V software after booting your computer. The reason is that the NRT-V software could have locked your computer’s serial
port(s), making it impossible for the NRTZUpdate program to connect to a sensor successfully. Making a long story short: if you want to
update the sensor firmware do it after a (re-)boot of your computer before eventually starting NRT-V.
Virtual NRT supports now more than 8 RS232 serial interfaces.
1.8.1 Enhancements
Added the software binary of the new measurement head NRT-Z14
The NRT-Z14 power sensor is enhanced by TETRA modulation measurement in firmware versions 1.70. The
NRT_V release 1.70 reflects this enhancement by an added TETRA modulation menu item.
If running under WIN95 for more than 2 hours continuously Virtual NRT has caused a system crash.
The performance of Virtual NRT has been extremely bad.
1.11.2 Enhancements
The new features of 1.40 firmware revision for NRT-Z43 / 44 are supported.
Improved design.
Direct communication panel runs smoother and more secure.
Auto - connection and com port scanning sequences run faster and more secure now.
RFR measurement function has been added.
Release 1.44
1.2 Enhancements since 1.43
The sensor's calibration data can be read and restored.
New sensor firmware can be loaded.
The user interface has got a lot of improvements and facelifts.
The auto scaler of the scope window is improved.
A COM port and baud rate scanner has been built in.
2 Release 1.43
2.1 Enhancements since former versions
The HELP->HELP popup window is replaced by a more extensive windows help file.
The interruption of block outputs as OPTIONS->HEAD SELFTEST has been improved and will not cause the
message "Port not open !" any longer.
With activated measurement function BURST AUTO and BURST USER, two lines per measurement were created in
the protocol file instead of one:
BURST
USER …
Now appears:
B.USER …
Virtual NRT Page 3 of 3