Вы находитесь на странице: 1из 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

DO NOT SCALE FROM THIS DRAWING

A A

EW01 EW02 EW03 EW05 B2_C2 BB NE06


E08 E081 E082 MB_E08_E09

MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316361 MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316361


TGWP-06H Ø110
B GWP @ T/B
Delegate's Office
B
TSP-06H Ø110
A00.30.76
SP @ T/B
14
01

7
TSP-07H Ø110

16

0
20
SP @ T/B
Delegate's Office

67
TGWP-07H Ø110 A00.30.77

20
TRWP-207 Ø315

98

MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316364
GWP @ T/B

94
10
RWP @F/A T/B

20
B.O.P. +2963 F/A
Ø110 SP @ H/L
11
9
RISE
MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316354

20
FD2a 79
Ø50 VP @ T/A 2

10
TRWP-206 Ø315 Pantry 03

4
40

L
RWP @F/A T/B A00.30.33

H/
22
13 MB_E08_E09

1
80

@
AAV

L
H/

P
C C

PE
GW
KS

90
1%

2
19

45

HD
81

10
B.O.P. +2854

S=

SP

Ø1
TRWP-205 Ø315 Ø50 VP @ H/L
B.O.P. -70

52
10
RWP @F/A T/B

Ø1

42
E074

1%
S=
RE
B.O.P. +2907
B.O.P. +2908 40 NE06
26
Ø1 S=

14
10 46

19
1% 5 B2_C3
SP
B.O.P. +3426 @ ?
H/
RE

135°
L
B.O.P. +3007

9
12

85
T/A

12
RE
RE
F/A
D RE
B.O.P. +2995
RISE
18
B.O.P. +2864
D

96
05 B.O.P. +2938 E082
B.O.P. +3426

11
Ø50 VP @ H/L
RE F/A 68 B.O.P. +2984
90° RISE 2
B.O.P. +2982

L
H/
64
RISE

15

@
F/A

P
GW

PE
B.O.P. +2844

2
B.O.P. +2847

42
DROP

HD
DROP

10
B.O.P. +2838 B.O.P. +2834

Ø1
TGWP-29 Ø110

75
RE GWP @ T/B Ø110 SP @ H/L

0
23
TSP-29 Ø110 Ø110 GWP @ H/L
SP @ T/B B.O.P. +2950
S= RE

49
B.O.P. +2793
1% B.O.P. +2810

18
E073 B.O.P. +3372

97
RE
Ø110 GWP @ F/A RE

25
B.O.P. +2807
E DROP
Ø75 SP @ H/L
B.O.P. +2845 E

0
65
B.O.P. +3407
Semi-Private Lounge B.O.P. +3031
Ø50 VP @ H/L B.O.P. +2810
06 B.O.P. +3238 RE

6
66
A00.30.16 Ø110 SP @ H/L DROP
B.O.P. +3216

1%
RISE B.O.P. +3042

63 74
Ø75 SP @ F/A NE05

5
2

S=
1%
B.O.P. +3241 B.O.P. +3200

38
47

S=
Ø75 SP @ F/A

31
RISE
B.O.P. +3254

Ø75 SP @ F/A
MB_E07_E08 B.O.P. +3260 Ø110 SP @ H/L

L
B.O.P. +3226

H/
Ø50 VP @ T/A
Corridor 99
RISE 9
13

@
A00.30.60a B.O.P. +3234 40

P
Ø110 SP @ F/A RE

GW

PE
HD
F F

10
FFL; 0.00

Ø1
E081
E072 Staircase
A01.S-HT-04.01a

Semi-Private Lounge
07
A00.30.17

57
23
G G
99 RE
2

4
99

3
FD2

77
FD2

0
AAV

74
E07
25 B.O.P. +2908
71 Ø50 VP @ F/A
RISE
B.O.P. +2933

90°
Security Search

H A00.30.60
FFL; 0.00
H

90°
E071

Semi-Private Lounge
08
A00.30.18 26
07
TSP-29 Ø110
17 SP @F/A T/B
9
TGWP-29 Ø110

L
H/
26 GWP @F/A T/B
18

@
TGWP-29A Ø110

P
E08

GW
34 GWP @ T/B

PE
4 TSP-29A Ø110

HD
10
18
B.O.P. +2831 SP @ T/B

Ø1
13
J FC
B.O.P. +2848 J

1
82
1%
S=

1%

1%
S=

S=
L
H/
Ø110 SP @ H/L
B.O.P. +2885

57
P
RISE

GW
B.O.P. +2922 Ø50 KWP @ B/FF NE04
Ø75 SP @ F/A

10

6
69
DROP TO B/L

Ø1
20 B.O.P. +2936
35 FD2a
B.O.P. +3394
RISE
K B.O.P. +2923 97 Ø50 VP @ T/A
RE
80
8 K

PE
5 B.O.P. +3274 KS

PE
HD
B.O.P. +2905 Ø50 VP @ F/A
RISE B.O.P. +4479

HD

3
82
Ø75 SP @ F/A Ø75 SP @ H/L 13
Ø110 SP @ F/A 8
29
61

0
Ø50 VP @ F/A 21

92
B.O.P. +3349 15
RISE DROP B.O.P. +4436
Ø75 SP @ F/A
Ø110 SP @ H/L

1%
DROP B.O.P. +2946

54
Ø1 Ø75 SP @ F/A
10

16
8
RE Ø110 SP @ F/A B.O.P. +4483

S=
99
GW

00
TRWP-204 Ø315 B.O.P. +3084 24 B.O.P. +2934

PE
20 12 HD P

19
55
98

RWP @F/A T/B PE @

HD
RE H/ B.O.P. +4199
10

L Ø110 GWP @ F/A

93°
44 Ø50 VP @ F/A
8 B.O.P. +2954 B.O.P. +4227

31
FFL; 0.00 RISE B.O.P. +4451
B.O.P. +4028

23
Ø110 SP @ F/A Ø110 SP @ F/A

L
21
1%
AAV

H/
B.O.P. +2937 B.O.P. +3301

12
Ø50 VP @ T/A 37

S=
Ø110 SP @ F/A
3

@
TRWP-203 Ø315 B.O.P. +3112 4
96

B.O.P. +2952 B.O.P. +4268 68


90°

P
RWP @F/A T/B 22 7

9
Pantry 04 RE

GW
13

62
F/A E074
DWG-02-000-EF-4316354

RE
L L

1%
Ø50 GWP @ H/L A00.30.34 RISE Ø50 VP @ F/A FD2a

81
RE DROP

10
73

B.O.P. -85

S=
B.O.P. +3360 Ø50 VP @ T/A

16
B.O.P. +4413

95

Ø1
10

FD2a B.O.P. +4755

MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316364
20 B.O.P. +3124 B.O.P. +2971 Ø50 GWP @ B/FF

11
36 B.O.P. +4885
F/A DROP TO B/L

90
26 RISE Ø75 SP @ F/A WC

4
RE B.O.P. +5355

26
18

51
RE B.O.P. +3497

1%
RE TR Room Ø50 VP @ F/A B.O.P. -78

02
Semi-Private Lounge RE Ø50 VP @ F/A
A00.SF-06.01c WB

12

S=
7
09 ? Ø50 GWP @ B/FF

96
TRWP-202 Ø315 F/A RE
A00.30.19 17 RISE B.O.P. +3497 DROP TO B/L WB
25 B.O.P. +3234 B.O.P. +4392 Ø110 SP @ F/A
RWP @F/A T/B Ø50 VP @ T/A B.O.P. +4921
B.O.P. +4424

79
81 11
2 1%

14
50

7
B.O.P. +3149

9
32

28
B.O.P. +4364

87
B.
Ø110 GWP @ F/A O.

25
P. 87
RE 45 +3 Ø110 SP @ F/A 18 6
Ø50 VP @ H/L 5 17
22
MATCHLINE SEE:MTT-PLB-DWG

B.O.P. +3157 9
B.O.P. -81
Ø1 28
Lobby 10 Corridor 14 AAV 5

PE
A00.SF-06.01b SP HD A00.36.01a 94

HD
PE Ø110 SP @ F/A

L
@

H/
M H/ FFL; 0.00 66
M

61
L Corridor 4

35

94°
Corridor A00.36.01a

SP
A00.SF-06.01d

10
RE

Ø1
Ø110 SP @ F/A

90°
76

KS
27

B.O.P. +3234
11

L
H/
5
B.O.P. +3185 B.O.P. +3908
12

89
DROP Ø50 GWP @ F/A

@
90
B.O.P. +2915 6

P
Semi-Private Lounge 78

GW

PE
6

10 18 FFL; 0.00
93
4

HD
72
25

10
A00.30.20

Ø1
TSP-36 Ø110
SP @ T/B B.O.P. +2901
Ø110 SP @ T/B
TGWP-36 Ø110
GWP @ T/B 75
1
N Large Office
N

1
77
Staircase A00.37.09

4
B.O.P. +3461

31
A00.SF-06.01a E073

TSP-05H Ø110 Ø110 GWP @ H/L


Ladies' Lounge
SP @ T/B RE B.O.P. +3479 A00.35.03
Head of HD
TGWP-05H Ø110 Department's Office PE
83

20 03 20
GWP @ T/B 16 87 01
26

8 A00.37.12
RE
11 Ø50 GWP @
86 51 B.O.P. +3486
DROP TO B/L 0
Ø110 GWP @ H/L
Corridor
WB A00.37.26

MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316401 WC MATCHLINE SEE:MTT-PLB-DWG-02-000-EF-4316401


A00.37.09a

O O

EW01 E07
E063 E064 MB_E07_E08
EW02 EW03 EW05 B2_C2 BB B2_C3 NE05 E071 NE04 E072

1 00_FFL_GROUND FLOOR PLAN_4316363


Scale : 1 : 100
P P

Contract Dwg No: B-43-000-1636 CONTRACTOR REVISIONS PROJECT CLIENT SCALE PAPER DRAWING TITLE
NOTE: MODEL REFERENCE: ENGINEER'S REPRESENTATIVE
SIZE
1. ALL DIMENSIONS, LEVELS AND SIZES ARE IN MILLIMETERS UNLESS SPECIFIED OTHERWISE. 1. AEC-ARC-MOD-02-900-EC-0000300 16. STD-STR-MOD-02-900-XX-0000800 Key Plan:
1601116012 1602116022
Multidisciplinary coordination for the content
and the engineering solutions in the drawing
No Date Description Originator Checked Verified 21/11/2017 1 : 100 A0 Plumbing
1601316014 1602316024
2. ALL SERVICES DIMENSIONS ARE MEASURED FROM +0.000M. 00 21/11/2017 Issued for Review And Approval AY AC MS
Q 3. PIPE SLEEVES TO BE PROVIDED FOR PENETRATION OF WALL & SLAB.
2. AEC-ARC-MOD-02-900-EF-0000200
3. GMW-ARC-MOD-02-900-EC-0000320
17. WSS-STR-MOD-02-900-EF-0000016
18. WSS-STR-MOD-02-900-EC-0000013
1603116032 1604116042
1603316034 1604316044
has been performed
KUWAIT INTERNATIONAL AIRPORT Q
4. ALL DRAWINGS ARE CO-ORDINATED WITH ALL TRADES. 4. GMW-ARC-MOD-02-900-EC-0000330 19. AEC-ARC-MOD-02-900-XX-0000101
1605116052 1606116062 1607116072 Architect Víctor Pérez ‫وزارة اﻷﺷﻐﺎل اﻟﻌﺎﻣﺔ‬
Riverside, 22 Hester Road
London SW11 4AN
DRAWING STATUS DEVELOPMENT STAGE
Kuwait International Airport
5. EQUIPMENT DIMENSION SHOWN AS PER PRELIMINARY SELECTION ONLY. ACTUAL
5. GMW-ARC-MOD-02-900-EC-0000340
1605316054 1606316064 1607316074
Structural Eng. Emre Temizkan MINISTRY OF PUBLIC WORKS T +44 (0)20 7738 0455
FOR REVIEW AND LOD400 Terminal II
20. AEC-BIM-MOD-02-000-00-0000002 1608116082 1609116092 1610116102 1611116112 1612116122 F +44 (0)20 7738 1107
EQUIPMENT DIMENSION SHALL BE REVISED AFTER FINAL MATERIAL APPROVAL.
6. PIPE EXPANSION JOINTS SHALL BE INSTALLED AT ALL CROSSINGS OF STRUCTURAL
EXPANSION JOINT.
6. GMW-ARC-MOD-02-900-EC-0003300 21. MTT-HVA-MOD-02-900-EC-0000101
1608316084 1609316094 1610316104 1611316114 1612316124
1613116132 1614116142 1615116152 1616116162 1617116172 1618116182 1619116192
Mechanical Eng. Fethi Akalin New Passenger Terminal II SPA/214 APPROVAL
Drainage Services
7. GMW-ARC-MOD-02-900-EF-0000220 22. MTT-HVA-MOD-02-900-EF-0000101 1613316134 1614316144 1615316154 1616316164 1617316174 1618316184 1619316194 Electrical Eng. Mehmet Koclar IN ASSOCIATION WITH: CONTRACTOR'S CONSULTANT CONTRACTOR'S CONSULTANT
7. FOR PUDDLE SLEEVES, PLEASE REFER TO DETAIL SHEETS OF SLEEVES ON RETAINING 8. GMW-ARC-MOD-02-900-EF-0000230 23. MTT-PLB-MOD-02-900-EC-0000101 1620116202 1621116212 1622116222 1623116232 1624116242 1625116252 1626116262
WALLS.
9. GMW-ARC-MOD-02-900-EF-0000240
1620316204 1621316214 1622316224 1623316234 1624316244 1625316254 1626316264 Desing Director İzzet Fikirlier
24. MTT-PLB-MOD-02-900-EF-0000101
1627116272 1628116282 1629116292 1630116302 1631116312 1632116322 1633116332
8. FOR STORM WATER EXTERNAL PIPING, PLEASE REFER TO TENDER UTILITIES SET B-92. h
ka Engineer's Rep
Mak
10. GMW-ARC-MOD-02-900-EF-0003200 25. MTT-PLB-MOD-02-900-X-0000211 1627316274 1628316284 1629316294 1630316304 1631316314 1632316324 1633316334
1634116342 1635116352 1636116362 1637116372 1638116382 STATE OF KUWAIT
11. PRB-STR-MOD-02-900-EC-3000001
1634316344 1635316354 1636316364 1637316374 1638316384 SIGNATURE DATE ORIGINATOR CHECKED BY VERIFIED BY REVISION
12. PRB-STR-MOD-02-900-EF-3000001 CONTRACTOR SHEET
13. STD-STR-MOD-02-900-EC-0000300
1639116392 1640116402 1641116412
1639316394 1640316404 1641316414
ACTION STAMP
P.O. Box 22412, Safat NAME NAME NAME NUMBER: MTT-PLB-DWG-02-000-EF-4316363
R
14. STD-STR-MOD-02-900-EF-0000200
15. PRB-STR-MOD-02-900-EZ-3000001
1646116462 1642116422 1643116432
1646316464 1642316424 1643316434
13085 Kuwait
T +965 24843565
AY AC MS
SHEET
GROUND FLOOR, LEVEL +0.00
00 R
N

1644116442 1645116452 F +965 24849532


1644316444 1645316454 www.gckuwait.com DATE 21/11/2017 DATE 21/11/2017 DATE 21/11/2017 NAME:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Вам также может понравиться