Вы находитесь на странице: 1из 5

DESIGN OF PUMP HUSE ROOF SLAB

Design Data

Dimensions of the slab (c/c distance b/w supports),

fck = 25 N/mm2

Length of short span, Lx


= 3.70 m fy = 500
N/mm2

Length of long span, Ly


= 4.20 m

Width of the supporting beam,


= 200 mm

Clear cover to main reinforcement


= 25 mm

Assume dia. of reinforcement steel


= 10 mm

Calculations

Assume the thickness of slab as


125 mm ; Effective depth,
d = 95 mm

Effective span, lx = 3.7 m


(or) 3.595 m whichever is less;
d = 3.595 m

ly = 4.2 m (or) 4.095 m


whichever is less;
d = 4.095 m

(ly / lx) = 1.14 < 2 ; Here, (ly / lx) is less


than 2, Hence design the slab as two way slab

Load Calculations

Interior Panels

Dead Load of slab = 0.125 x 25


= 3.13 KN/m2 Dust Load on slab
= 0 KN/m2
One Short Edge
Discontinuous

Live Load on slab


= 1.5 KN/m2

Two Adjacent Edges Discontinuous

Total Dead load acting on the Structure


= 3.13 KN/m2

Two Short
Edges Discontinuous

Total live load acting on the Structure


= 1.5 KN/m2

Factored Design Load


w = 6.20 KN/m2

Two Long Edges Discontinuous


Three Edges Discontinuous (One Long Edge
Continuous)

Support Condition (Type of panel according


to support condition)

Three Edges Discontinuous (One Short Edge Continuous)

Three Edges Discontinuous (One Long Edge Continuous)

For this support condition,

Four Edges Discontinuous

Short span coefficient for (ly / lx) =


1.14, Long span
coefficient,

14

For negative moment,


ax = 0.0668 For negative
moment, ay = 0

For positive moment,


ax = 0.0500 For positive
moment, ay = 0.043

Moment Calculation

Max. BM per unit width, Mx


= ax w lx2 & My = ay w lx2

Mu Mu / bd2
pt Ast, req Ast , min =
(0.12/100) bD = 150 mm2
KNm N/mm2 %
mm2

For Short Span,


Reinforcement details

At mid span, 4.01 0.44


0.1245 118

At supports, 5.35 0.59


0.1682 160 Provide Y
8 @ 150 mm c/c at midspan &

For Long span,


supports for short span
(Ast pro. = 335
mm2 )

At mid span, 3.45 0.48


0.1361 129 Provide Y
8 @ 150 mm c/c at midspan &

At supports, 0.00 0.00


0 0 supports for long span
(Ast pro. = 335
mm2 )

Check for Deflection

Percentage of tension reinforcement


= 0.35 %

fs = 0.58 fy (Ast req / Ast pro)


= 102.1126847
Refer Fig. 4 of IS 456,

Modification factor
= 2.000

Allowable (Span / deff ) ratio


= 40

20 26

Effective depth required


= 90 mm

< d prov.

Hence OK