Parameter report

Device tag: Promass

Device information
Device tag Promass
Module name C300-02
Nominal diameter DN150 / 6"
Device name Promass 300
Order code O8F3B1F-11A5/0
Serial number N300B216000
Firmware version 01.01.02

Protocol created 2018-04-20 09:46


Operating time (counter)

Notes

Date Operator's signature Inspector's signature

www.endress.com Page 1
Parameter report

Menu/Operation /
Web server language English
Display language English
Access status Maintenance
Format display 4 values

Menu/Operation /Display /
Contrast display 50 %
Backlight Enable
Display interval 5s

Menu/Operation /Totalizer handling/


Control Totalizer 1 Totalize
Preset value 1 0.0000 bbl (us;oil)
Control Totalizer 2 Totalize
Preset value 2 0.0000 m³
Control Totalizer 3 Totalize
Preset value 3 0.0000 m³
Reset all totalizers Cancel

Menu/Operation /Custody transfer/


Custody transfer mode Off
Firmware version 01.01.02
Checksum 0x2AAB
Custody transfer counter 0
Custody transfer locking Defined parameters
Timestamp last custody transfer
Display test Cancel

Menu/Operation /Weighted averages/


Reset weighted averages Totalize

Menu/Setup /
Device tag Promass

www.endress.com Page 2
Parameter report

Menu/Setup /System units/


Mass flow unit lb/min
Mass unit lb
Volume flow unit bbl/h (us;oil)
Volume unit bbl (us;oil)
Corrected volume flow unit Sbbl/h (us;liq.)
Corrected volume unit Sbbl (us;liq.)
Density unit g/cm³
Reference density unit g/Scm³
Temperature unit °F
Pressure unit psi g

Menu/Setup /Communication/
Bus address 247
Baudrate 19200 BAUD
Data transfer mode RTU
Parity Even
Byte order 1-0-3-2
Failure mode NaN value

Menu/Setup /Medium selection/


Select medium Liquid

Menu/Setup /I/O configuration/


I/O module 1 terminal numbers 26-27 (I/O 1)
I/O module 1 information MODBUS
I/O module 2 terminal numbers 24-25 (I/O 2)
I/O module 2 information Configurable
I/O module 2 type Current output
I/O module 3 terminal numbers 22-23 (I/O 3)
I/O module 3 information Configurable
I/O module 3 type Pulse/frequency/switch output
Alteration code 0

Menu/Setup /Current output 1/


Assign current output 1 Density
Terminal number 24-25 (I/O 2)

www.endress.com Page 3
Parameter report

Menu/Setup /Pulse/frequency/switch output 1/


Operating mode Pulse
Terminal number 22-23 (I/O 3)

Menu/Setup /Low flow cut off/


Assign process variable Volume flow

Menu/Setup /Partially filled pipe detection/


Assign process variable Density

Menu/Setup /Advanced setup/Calculated values/Corrected volume


flow calculation/
Corrected volume flow calculation Calculated reference density
Reference temperature 68.0000 °F
Linear expansion coefficient 0.000000e+00 1/K
Square expansion coefficient 0.000000e+00 1/K²

Menu/Setup /Advanced setup/Sensor adjustment/


Installation direction Flow in arrow direction

Menu/Setup /Advanced setup/Sensor adjustment/Zero point


adjustment/
Zero point adjustment control Cancel
Progress 100

Menu/Setup /Advanced setup/Totalizer 1/


Assign process variable Volume flow
Unit totalizer 1 bbl (us;oil)
Totalizer operation mode Net flow total
Failure mode Actual value

Menu/Setup /Advanced setup/Totalizer 2/


Assign process variable Volume flow
Unit totalizer 2 m³
Totalizer operation mode Net flow total
Failure mode Stop

www.endress.com Page 4
Parameter report

Menu/Setup /Advanced setup/Totalizer 3/


Assign process variable Volume flow
Unit totalizer 3 m³
Totalizer operation mode Net flow total
Failure mode Stop

Menu/Setup /Advanced setup/Custody transfer activation/


Authorized user login Stop

Menu/Setup /Advanced setup/Display /


Value 1 display Volume flow
0% bargraph value 1 0.0000 bbl/h (us;oil)
100% bargraph value 1 56.6083 bbl/h (us;oil)
Decimal places 1 x.xx
Value 2 display Totalizer 1
Decimal places 2 x.xx
Value 3 display Density
0% bargraph value 3 0.5000 g/cm³
100% bargraph value 3 2.0000 g/cm³
Decimal places 3 x.xx
Value 4 display None
Display damping 0.0 s
Header Device tag
Separator .

Menu/Setup /Advanced setup/WLAN settings/


WLAN Enable

Menu/Setup /Advanced setup/Concentration/Concentration settings/


Liquid type Off

www.endress.com Page 5
Parameter report

Menu/Setup /Advanced setup/Concentration/Concentration profile 1/


Coefficients set name Coef Set No. 1
A0 -7.2952
A1 15.1555
A2 -11.6756
A3 4.4759
A4 -0.6615
B1 722.0000 E-3
B2 38912600 E-6
B3 -1.6739e+09 E-9
D1 -9.7500 E-2
D2 -3731.000 E-4
D3 295.7000 E-3
D4 -17210.00 E-5

Menu/Setup /Advanced setup/Concentration/Concentration profile 2/


Coefficients set name Coef Set No. 2
A0 -7.2952
A1 15.1555
A2 -11.6756
A3 4.4759
A4 -0.6615
B1 722.0000 E-3
B2 38912600 E-6
B3 -1.6739e+09 E-9
D1 -9.7500 E-2
D2 -3731.000 E-4
D3 295.7000 E-3
D4 -17210.00 E-5

www.endress.com Page 6
Parameter report

Menu/Setup /Advanced setup/Concentration/Concentration profile 3/


Coefficients set name Coef Set No. 3
A0 -7.2952
A1 15.1555
A2 -11.6756
A3 4.4759
A4 -0.6615
B1 722.0000 E-3
B2 38912600 E-6
B3 -1.6739e+09 E-9
D1 -9.7500 E-2
D2 -3731.000 E-4
D3 295.7000 E-3
D4 -17210.00 E-5

Menu/Setup /Advanced setup/Petroleum/


Petroleum mode Off
API commodity group A - crude oil
API table selection API table 53/54
Pressure compensation Off
Temperature correction source Internal measured value
Shrinkage factor 1.0000
Meter factor 1.0000

Menu/Setup /Advanced setup/Heartbeat setup/Heartbeat base


settings/
Record application reference data Cancel
Status Done
Plant operator --------------------------------
Location --------------------------------

Menu/Setup /Advanced setup/Heartbeat setup/Heartbeat


Verification/
Select reference data Factory air calibration

Menu/Setup /Advanced setup/Configuration backup/


Operating time 13d22h04m15s
Last backup 0d00h00m00s
Configuration management Cancel
Backup state None
Comparison result Check not done

www.endress.com Page 7
Parameter report

Menu/Setup /Advanced setup/Administration/


Device reset Cancel

Menu/Setup /Advanced setup/Administration/Reset access code/


Reset access code Cancel

Menu/Diagnostics /
Actual diagnostics 0
Previous diagnostics 0
Operating time from restart 3d21h42m29s

Menu/Diagnostics /Diagnostic list/


Diagnostics 1 0
Diagnostics 2 0
Diagnostics 3 0
Diagnostics 4 0
Diagnostics 5 0

Menu/Diagnostics /Event logbook/


Filter options All
Clear event list Cancel

Menu/Diagnostics /Custody transfer logbook/


Logbook entry 1
Entry 30 of custody transfer logbook 0
Event number 0
Event logbook --------
Timestamp

Menu/Diagnostics /Device information /


Device tag Promass
Serial number N300B216000
Device name Promass 300
Order code O8F3B1F-11A5/0
Extended order code 1 O8F3B1F-CDDMADDFADSA
Extended order code 2 ACSAA1FA
Extended order code 3 ACSAA1FA
ENP version 2.02.00

www.endress.com Page 8
Parameter report

Menu/Diagnostics /Measured values /Measured variables/


Mass flow 0.0000 lb/min
Volume flow 0.0000 bbl/h (us;oil)
Corrected volume flow 0.0000 Sbbl/h (us;liq.)
Density 0.9288 g/cm³
Reference density 0.9288 g/Scm³
Temperature 57.6 °F
Pressure value -9.5367e-07 psi g

Menu/Diagnostics /Measured values /Output values/Current output


1/
Output current 1 12.41 mA
Measured current 1 12.45 mA

Menu/Diagnostics /Measured values /Output values/Pulse/


frequency/switch output 1/
Pulse output 1 0.000 Hz

Menu/Diagnostics /Measured values /Totalizer /


Totalizer value 1 10051.70 bbl (us;oil)
Totalizer overflow 1 0
Totalizer value 2 1600.905 m³
Totalizer overflow 2 0
Totalizer value 3 -1.2878 m³
Totalizer overflow 3 0

Menu/Diagnostics /Data logging/


Data logging Overwriting

Menu/Diagnostics /Heartbeat/Performing verification /


Year 10
Month January
Day 1
Hour 12
Minute 0
Start verification Cancel
Status Not done
Overall result Not done

www.endress.com Page 9
Parameter report

Menu/Diagnostics /Simulation /
Assign simulation process variable Off
Current output 1 simulation Off
Pulse output simulation 1 Off
Device alarm simulation Off
Diagnostic event simulation 65533
Diagnostic event category Process
Diagnostic event simulation Off

Menu/Expert/System/Diagnostic handling/
Alarm delay 0s

Menu/Expert/System/Diagnostic handling/Diagnostic behavior/


Assign behavior of diagnostic no. 046 Alarm
Assign behavior of diagnostic no. 140 Alarm
Assign behavior of diagnostic no. 144 Alarm
Assign behavior of diagnostic no. 374 Warning
Assign behavior of diagnostic no. 302 Warning
Assign behavior of diagnostic no. 441 Warning
Assign behavior of diagnostic no. 442 Warning
Assign behavior of diagnostic no. 443 Warning
Assign behavior of diagnostic no. 830 Warning
Assign behavior of diagnostic no. 831 Warning
Assign behavior of diagnostic no. 832 Logbook entry only
Assign behavior of diagnostic no. 833 Logbook entry only
Assign behavior of diagnostic no. 834 Warning
Assign behavior of diagnostic no. 835 Warning
Assign behavior of diagnostic no. 862 Warning
Assign behavior of diagnostic no. 912 Warning
Assign behavior of diagnostic no. 913 Warning
Assign behavior of diagnostic no. 944 Warning
Assign behavior of diagnostic no. 948 Warning

Menu/Expert/System/Administration/
Activate SW option 25450284
Date/time format dd.mm.yy hh:mm

www.endress.com Page 10
Parameter report

Menu/Expert/Sensor/Process parameters/
Flow damping 0.00 s
Density damping 0.00 s
Temperature damping 0.00 s
Flow override Off

Menu/Expert/Sensor/Process parameters/Low flow cut off/


On value low flow cutoff 5.0000 bbl/h (us;oil)
Off value low flow cutoff 50 %
Pressure shock suppression 0.0 s

Menu/Expert/Sensor/Process parameters/Partially filled pipe


detection/
Low value partial filled pipe detection 0.2000 g/cm³
High value partial filled pipe detection 6.0000 g/cm³
Response time part. filled pipe detect. 1.0 s
Maximum damping partial filled pipe det. 0.00

Menu/Expert/Sensor/External compensation/
Temperature mode Internal measured value

Menu/Expert/Sensor/Sensor adjustment/Density adjustment/


Density adjustment mode 1 point adjustment

Menu/Expert/Sensor/Sensor adjustment/Process variable


adjustment/
Mass flow offset 0.0000 kg/s
Mass flow factor 1.0000
Volume flow offset 0.0000 m³/s
Volume flow factor 1.0000
Density offset 0.0000 kg/m³
Density factor 1.0000
Corrected volume flow offset 0.0000 Nm³/s
Corrected volume flow factor 1.0000
Reference density offset 0.0000 kg/Nm³
Reference density factor 1.0000
Temperature offset 0.0000 K
Temperature factor 1.0000

www.endress.com Page 11
Parameter report

Menu/Expert/Sensor/Calibration/
Calibration factor 0.9003
Zero point -28
Nominal diameter DN150 / 6"
C0 -2115.541
C1 180774144
C2 -86590.33
C3 8496.385
C4 0.0000
C5 0.0000
A0 131.2613
A1 1250.000
A2 0.0000
A3 0.4839
A4 0.0000
Calibration date/time 08.03.18 13:43

Menu/Expert/Sensor/Calibration/Recalibration/
Calibration factor 1.000

Menu/Expert/Sensor/Calibration/Logbook/
Calibration counter 1
Select calibration log entry 1
Timestamp 08.03.18 13:43
Calibration factor 0.900

www.endress.com Page 12
Parameter report

Menu/Expert/Sensor/Testpoints/
Oscillation frequency 0 242.939 Hz
Oscillation frequency 1 0.000 Hz
Frequency fluctuation 0 5.3218e-06
Frequency fluctuation 1 0.0000
Oscillation amplitude 0 100.0 %
Oscillation amplitude 1 0.0 %
Oscillation damping 0 1209.85
Oscillation damping 1 0.00
Oscillation damping fluctuation 0 5.2373e-05
Oscillation damping fluctuation 1 0.0000
Signal asymmetry 1.1 %
Torsion signal asymmetry 0.0 %
Sensor electronic temperature (ISEM) 87.4 °F
Carrier pipe temperature 60.4 °F
Exciter current 0 0.0107 A
Exciter current 1 0.0000 A
RawMassFlow -2.4956 lb/min
Reynolds number 0.7

Menu/Expert/Output /Current output 1/


Signal mode Active
Current span 4...20 mA NAMUR
0/4 mA value 0.850 g/cm³
20 mA value 1.000 g/cm³
Measuring mode Forward flow
Damping output 1 1.0 s
Response time 1.0000 s
Failure mode Actual value
Trim Off
Status 128

www.endress.com Page 13
Parameter report

Menu/Expert/Output /Pulse/frequency/switch output 1/


Signal mode Active
Assign pulse output 1 Volume flow
Value per pulse 0.0001 bbl (us;oil)
Pulse width 0.05 ms
Measuring mode Forward flow
Failure mode No pulses
Invert output signal No

Menu/Expert/Communication/Modbus configuration/
Telegram delay 6 ms
Bus termination Off
Fieldbus writing access Read + write

Menu/Expert/Communication/Modbus information/
Device ID 0x643B
Device revision 0x201

Menu/Expert/Communication/Modbus data map/


Scan list register 0 0
Scan list register 1 0
Scan list register 2 0
Scan list register 3 0
Scan list register 4 0
Scan list register 5 0
Scan list register 6 0
Scan list register 7 0
Scan list register 8 0
Scan list register 9 0
Scan list register 10 0
Scan list register 11 0
Scan list register 12 0
Scan list register 13 0
Scan list register 14 0
Scan list register 15 0

www.endress.com Page 14
Parameter report

Menu/Expert/Communication/Web server/
MAC address 00-07-05-12-71-D1
DHCP client Off
IP address 192.168.1.212
Subnet mask 255.255.255.0
Default gateway 0.0.0.0
Web server functionality On
Login page With header

Menu/Expert/Application/Inventory counter/
Totalizer value 72036.79 kg
Totalizer overflow 0
Unit kg

Menu/Expert/Application/Concentration/Mineral content
determination/
Control mineral content determination Cancel
State mineral content determination Not done

Menu/Expert/Diagnostics /Sensor module/


Hardware revision V1.00.00
Module name Promass F
Serial number 5133174

Menu/Expert/Diagnostics /Main electronic module + I/O module 1/


Software revision 10102
Build no. software 0
Hardware revision V1.00.00
Module name C300-02
Serial number 0134528371
Bootloader revision 56

Menu/Expert/Diagnostics /Sensor electronic module (ISEM)/


Software revision 20101
Build no. software 0
Hardware revision V1.02.00
Module name V312-05
Serial number 0130938457
Bootloader revision 28

www.endress.com Page 15
Parameter report

Menu/Expert/Diagnostics /I/O module 2/


Software revision 10001
Build no. software 0
Hardware revision V1.00.00
Module name U300-01
Serial number 0135833351
Bootloader revision 10011

Menu/Expert/Diagnostics /I/O module 3/


Software revision 10001
Build no. software 0
Hardware revision V1.00.00
Module name U300-01
Serial number 0135843992
Bootloader revision 10011

Menu/Expert/Diagnostics /Display module /


Software revision 10108
Build no. software 0
Hardware revision V1.00.00
Module name A300
Serial number 0134661986
Bootloader revision 10007

Menu/Expert/Diagnostics /Min/max values /


Reset min/max values Cancel

Menu/Expert/Diagnostics /Min/max values /Electronic temperature/


Minimum value 66.5 °F
Maximum value 120.4 °F

Menu/Expert/Diagnostics /Min/max values /Medium temperature/


Minimum value 51.5 °F
Maximum value 107.3 °F

Menu/Expert/Diagnostics /Min/max values /Carrier pipe


temperature/
Minimum value 49.7 °F
Maximum value 112.7 °F

www.endress.com Page 16
Parameter report

Menu/Expert/Diagnostics /Min/max values /Oscillation frequency/


Minimum value 239.9 Hz
Maximum value 291.4 Hz

Menu/Expert/Diagnostics /Min/max values /Oscillation amplitude/


Minimum value 0.8 %
Maximum value 116.2 %

Menu/Expert/Diagnostics /Min/max values /Oscillation damping/


Minimum value -390.8
Maximum value 237607.8

Menu/Expert/Diagnostics /Min/max values /Signal asymmetry/


Minimum value 0.9 %
Maximum value 4.7 %

Menu/Expert/Diagnostics /Min/max values /Torsion signal


asymmetry/
Minimum value 1.0e+34 %
Maximum value -1.0e+34 %

www.endress.com Page 17