Processes
Submerged Arc (SAW) Welding
Description
Mil_Thank 2009−09
TABLE OF CONTENTS
MILLER Electric Mfg. Co., 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the
product(s) identified in this declaration conform to the essential requirements and provisions of
the stated Council Directive(s) and Standard(s).
Product/Apparatus Identification:
Product Stock Number
Subarc AC/DC 1250 Digital 907621
SubArc AC/DC 1000 Digital 907620
Council Directives:
• 2006/95/EC Low Voltage
• 2004/108/EC Electromagnetic Compatibility
• 2011/65/EU Restriction of the use of certain Hazardous Substances in electrical and electronic equipment
Standards:
• IEC 609741:2005 Arc welding equipment – Part 1: Welding power sources
• IEC 6097410:2007 Arc Welding Equipment – Part 10: Electromagnetic compatibility (EMC) requirements
Signatory:
_____________________________________ ___________________________________________
David A. Werba Date of Declaration
266177A
−6−
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som 2013−09
7
Protect yourself and others from injury — read, follow, and save these important safety precautions and operating instructions.
Welding or cutting equipment produces fumes or gases This product contains chemicals, including lead, known to
which contain chemicals known to the State of California to the state of California to cause cancer, birth defects, or other
cause birth defects and, in some cases, cancer. (California reproductive harm. Wash hands after use.
Health & Safety Code Section 25249.5 et seq.)
Pour écarter les risques de blessure pour vous−même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relatives
aux précautions de sécurité et au mode opératoire.
DANGER! − Indique une situation dangereuse qui si on . Indique des instructions spécifiques.
l’évite pas peut donner la mort ou des blessures graves.
Les dangers possibles sont montrés par les symboles
joints ou sont expliqués dans le texte.
Indique une situation dangereuse qui si on l’évite pas
peut donner la mort ou des blessures graves. Les dan-
gers possibles sont montrés par les symboles joints ou Ce groupe de symboles veut dire Avertissement! Attention! DANGER
sont expliqués dans le texte. DE CHOC ELECTRIQUE, PIECES EN MOUVEMENT, et PIECES
CHAUDES. Consulter les symboles et les instructions ci-dessous y
NOTE − Indique des déclarations pas en relation avec des blessures
afférant pour les actions nécessaires afin d’éviter le danger.
personnelles.
D À l’intérieur, ventiler la zone et/ou utiliser une ventilation forcée au D Surveiller tout déclenchement d’incendie et tenir un extincteur à
niveau de l’arc pour l’évacuation des fumées et des gaz de proximité.
soudage. Pour déterminer la bonne ventilation, il est recommandé D Le soudage effectué sur un plafond, plancher, paroi ou séparation
de procéder à un prélèvement pour la composition et la quantité peut déclencher un incendie de l’autre côté.
de fumées et de gaz auxquels est exposé le personnel.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que
D Si la ventilation est médiocre, porter un respirateur anti-vapeurs des réservoirs, tambours, ou conduites, à moins qu’ils n’aient été
approuvé. préparés correctement conformément à AWS F4.1 et AWS A6.0
D Lire et comprendre les fiches de données de sécurité et les instruc- (voir les Normes de Sécurité).
tions du fabricant concernant les adhésifs, les revêtements, les D Ne soudez pas si l’air ambiant est chargé de particules, gaz, ou va-
nettoyants, les consommables, les produits de refroidissement, les peurs inflammables (vapeur d’essence, par exemple).
dégraisseurs, les flux et les métaux.
D Brancher le câble de masse sur la pièce le plus près possible de la
D Travailler dans un espace fermé seulement s’il est bien ventilé ou zone de soudage pour éviter le transport du courant sur une
en portant un respirateur à alimentation d’air. Demander toujours à longue distance par des chemins inconnus éventuels en provo-
un surveillant dûment formé de se tenir à proximité. Des fumées et quant des risques d’électrocution, d’étincelles et d’incendie.
des gaz de soudage peuvent déplacer l’air et abaisser le niveau
d’oxygène provoquant des blessures ou des accidents mortels. D Ne pas utiliser le poste de soudage pour dégeler des conduites ge-
S’assurer que l’air de respiration ne présente aucun danger. lées.
D Ne pas souder dans des endroits situés à proximité d’opérations D En cas de non utilisation, enlever la baguette d’électrode du porte-
de dégraissage, de nettoyage ou de pulvérisation. La chaleur et électrode ou couper le fil à la pointe de contact.
les rayons de l’arc peuvent réagir en présence de vapeurs et for- D Porter un équipement de protection pour le corps fait d’un matériau
mer des gaz hautement toxiques et irritants. résistant et ignifuge (cuir, coton robuste, laine). La protection du
D Ne pas souder des métaux munis d’un revêtement, tels que l’acier corps comporte des vêtements sans huile comme par ex. des
galvanisé, plaqué en plomb ou au cadmium à moins que le revête- gants de cuir, une chemise solide, des pantalons sans revers, des
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit chaussures hautes et une casquette.
bien ventilé, et en portant un respirateur à alimentation d’air. Les D Avant de souder, retirer toute substance combustible de vos po-
revêtements et tous les métaux renfermant ces éléments peuvent ches telles qu’un allumeur au butane ou des allumettes.
dégager des fumées toxiques en cas de soudage.
D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
LES RAYONS DE L’ARC peuvent trace d’étincelles incandescentes ni de flammes.
provoquer des brûlures dans les D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
yeux et sur la peau. Ne pas augmenter leur puissance; ne pas les ponter.
Le rayonnement de l’arc du procédé de soudage D Une fois le travail achevé, assurez−vous qu’il ne reste aucune
génère des rayons visibles et invisibles intenses trace d’étincelles incandescentes ni de flammes.
(ultraviolets et infrarouges) susceptibles de provoquer des brûlures D Utiliser exclusivement des fusibles ou coupe−circuits appropriés.
dans les yeux et sur la peau. Des étincelles sont projetées pendant le Ne pas augmenter leur puissance; ne pas les ponter.
soudage.
D Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et
D Porter un casque de soudage approuvé muni de verres filtrants NFPA 51B pour les travaux à chaud et avoir de la surveillance et un
approprié pour protéger visage et yeux pour protéger votre visage extincteur à proximité.
et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 D Lire et comprendre les fiches de données de sécurité et les instruc-
et Z87.1 énuméré dans les normes de sécurité).
tions du fabricant concernant les adhésifs, les revêtements, les
D Porter des lunettes de sécurité avec écrans latéraux même sous nettoyants, les consommables, les produits de refroidissement,
votre casque. les dégraisseurs, les flux et les métaux.
OM-265 364 Page 6
DES PIECES DE METAL ou DES LES BOUTEILLES peuvent exploser
SALETES peuvent provoquer des si elles sont endommagées.
blessures dans les yeux. Les bouteilles de gaz comprimé contiennent du gaz
sous haute pression. Si une bouteille est
D Le soudage, l’écaillement, le passage de la endommagée, elle peut exploser. Du fait que les
pièce à la brosse en fil de fer, et le meulage gé- bouteilles de gaz font normalement partie du
nèrent des étincelles et des particules procédé de soudage, les manipuler avec
métalliques volantes. Pendant la période de précaution.
refroidissement des soudures, elles risquent D Protéger les bouteilles de gaz comprimé d’une chaleur excessi-
de projeter du laitier. ve, des chocs mécaniques, des dommages physiques, du lai-
D Porter des lunettes de sécurité avec écrans latéraux ou un écran tier, des flammes ouvertes, des étincelles et des arcs.
facial. D Placer les bouteilles debout en les fixant dans un support sta-
tionnaire ou dans un porte-bouteilles pour les empêcher de tom-
ber ou de se renverser.
LES ACCUMULATIONS DE GAZ D Tenir les bouteilles éloignées des circuits de soudage ou autres
risquent de provoquer des blessures circuits électriques.
ou même la mort. D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Fermer l’alimentation du gaz comprimé en cas D Une électrode de soudage ne doit jamais entrer en contact avec
de non utilisation. une bouteille.
D Veiller toujours à bien aérer les espaces confi- D Ne jamais souder une bouteille pressurisée − risque d’explosion.
nés ou se servir d’un respirateur d’adduction
d’air homologué. D Utiliser seulement des bouteilles de gaz comprimé, régulateurs,
tuyaux et raccords convenables pour cette application
Les CHAMPS ÉLECTROMAGNÉTIQUES spécifique; les maintenir ainsi que les éléments associés en bon
état.
(CEM) peuvent affecter les implants mé-
D Tourner le dos à la sortie de vanne lors de l’ouverture de la vanne
dicaux. de la bouteille. Ne pas se tenir devant ou derrière le régulateur
lors de l’ouverture de la vanne.
D Les porteurs de stimulateurs cardiaques et
autres implants médicaux doivent rester à D Le couvercle du détendeur doit toujours être en place, sauf lors-
distance. que la bouteille est utilisée ou qu’elle est reliée pour usage ulté-
rieur.
D Les porteurs d’implants médicaux doivent consulter leur
D Utiliser les équipements corrects, les bonnes procédures et suf-
médecin et le fabricant du dispositif avant de s’approcher de la
fisamment de personnes pour soulever et déplacer les bouteil-
zone où se déroule du soudage à l’arc, du soudage par points, du les.
gougeage, de la découpe plasma ou une opération de chauffage
par induction. D Lire et suivre les instructions sur les bouteilles de gaz comprimé,
l’équipement connexe et le dépliant P-1 de la CGA (Compressed
Gas Association) mentionné dans les principales normes de sé-
LE BRUIT peut endommager l’ouïe. curité.
Les équipements de soudage et de coupage produisent des Ce produit contient des produits chimiques, notamment du
fumées et des gaz qui contiennent des produits chimiques plomb, dont l’État de Californie reconnaît qu’ils provoquent
dont l’État de Californie reconnaît qu’ils provoquent des mal- des cancers, des malformations congénitales ou d’autres
formations congénitales et, dans certains cas, des cancers. problèmes de procréation. Se laver les mains après
(Code de santé et de sécurité de Californie, chapitre 25249.5 utilisation.
et suivants)
SECTION 3 − DEFINITIONS
Warning! Watch Out! There are possible hazards as shown by the symbols.
Safe1 2012−05
Safe5 2012−05
? V
? A Consult rating label for input power requirements.
Safe34 2012−05
Safe104 2012−09
Safe105 2012−09
Safe103 2012−09
Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
Safe2 2012−05
Safe20 2012−05
Safe16 2012−05
Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it.
Safe14 2012−05
Safe12 2012−05
Safe8 2012−05
Safe6 2012−05
Protect yourself from electric shock by insulating yourself from work and ground.
Safe3 2012−05
Safe40 2012−05
Wear hat and safety glasses. Use ear protection and button shirt
collar. Use welding helmet with correct shade of filter. Wear complete
body protection.
Safe38 2012−05
Safe116 2014−02
TB1 217 342-A
V Voltage
I2 Rated Welding
Current
Ventilating And Air
Circulating Fan
Hz Hertz
IP Degree Of
Protection
Increase/
Decrease
Negative Weld
Temperature
X Duty Cycle Output Terminal
Positive Weld
Output On Output Terminal
Circuit Breaker
Supplementary Disturbance TE Terminal Strip
Protector
Electrode
Panel/Local Read Operator’s Connection
Manual
Direct Current
Rated Maximum
Remote
I1max Supply Current
(DC)
U0 Rated No−Load
Voltage (OCV)
I1eff
Maximum
Effective Supply
Current
CC Constant Current
U2 Conventional
Load Voltage
SECTION 4 − SPECIFICATIONS
4-2. Specifications
! This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
C. Information On Electromagnetic Compatibility (EMC) For Power Sources Covered In This Manual
! This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
IEC/TS 61000−3−4 can be used to guide parties concerned by the installation of arc welding equipment with an input current greater than 75
A in a low-voltage network.
ce-emc 5 2014-07
Overheating
0 A/V
15
OR
Minutes Reduce Duty Cycle
duty1 4/95 − 181 560
SECTION 5 − INSTALLATION
E
D 25-5/16 in. (643 mm)
Front
4 holes:
E 21/32 in. (6.5 mm) dia C
D
5-2. Tipping
! Do not move or operate unit
where it could tip.
Location
3
18 in.
(460 mm)
18 in.
(460 mm) 265 690-A
3
5
2
A. 1000 Models
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Three-Phase, 60 Hz
B. 1250 Models
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated circuit sized for the rated output and duty cycle of the welding power source.
In dedicated circuit installations, the National Electrical Code (NEC) allows the receptacle or conductor rating to be less than the rating
of the circuit protection device. All components of the circuit must be physically compatible. See NEC articles 210.21, 630.11, and
630.12.
Three-Phase, 50 Hz
Min Input Conductor Size In AWG 4 (mm 2) 1/0 (50) 1/0 (50)
Max Recommended Input Conductor Length In Feet (Meters) 323 (98) 352 (107)
Notes
10
4
6 L1 (U)
L2 (V) 6
L3 (W)
5
Terminal Block
4
3
Tools Needed:
7/16 in.
3/8 in.
= GND/ PE Earth Ground
3/16 in.
! Installation must meet all National 1 Input Power Conductors (Customer Connect input conductors L1 (U), L2 (V) and
and Local Codes − have only qualified Supplied Cord) L3 (W) to welding power source line
persons make this installation. terminals.
Select size and length of conductors using
Section 5-5. Conductors must comply with Close and secure access door on welding
! Disconnect and lockout/tagout input
power source.
power before connecting input con- national, state, and local electrical codes. If
ductors from unit. Follow established applicable, use lugs of proper amperage Disconnect Device Input Power Connec-
procedures regarding the installation capacity and correct hole size. tions
and removal of lockout/tagout Welding Power Source Input Power Con- 7 Disconnect Device (switch shown in
devices. nections OFF position)
! Make input power connections to the 2 Strain Relief (Customer Supplied) 8 Disconnect Device (Supply) Grounding
welding power source first. Terminal
Install strain relief of proper size for unit and
9 Disconnect Device Line Terminals
! Always connect green or green/yel- conductors. Route conductors (cord)
low conductor to supply grounding through strain relief and tighten screws. Connect green or green/yellow grounding
terminal first, and never to a line ter- conductor to disconnect device grounding
3 Welding Power Source Grounding terminal first.
minal. Terminal
Connect input conductors L1 (U), L2 (V) And
! When using multiple units which will 4 Green Or Green/Yellow Grounding L3 (W) to disconnect device line terminals.
be linked with the synchronizing ter- Conductor
minal strip TE1, ensure that primary 10 Over-Current Protection
Connect green or green/yellow grounding
input power conductors are con- Select type and size of over-current protec-
conductor to welding power source ground-
nected to each unit in the same se- tion using Section 5-5 (fused disconnect
ing terminal first.
quence (L1 to L1, L2 to L2, and L3 to switch shown).
L3.) 5 Welding Power Source Line Terminals Close and secure door on line disconnect de-
See rating label on unit and check input volt- 6 Input Conductors L1 (U), L2 (V) And L3 vice. Follow established lockout/tagout pro-
age available at site. (W) cedures to put unit in service.
input3 2012−05
Notes
Terminal Block
6-1. Terminal Strip TE2 and Remote Receptacle RC1 Information For Power Sources
1 2
2
1
A B C E D F H M L
Tools Needed:
5/16 in.
265690-B / 261064-A
C Remote command reference +10 VDC. Connecting terminals C, D, and E will allow remote control.
E Output command 0 − +10 VDC. Connecting terminals C, D, and E will allow remote control.
D Remote common.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
Weld Output
Terminals
2
6
3
1
4
Tools Needed:
3/4 in. (19 mm)
5
803 778-B
! Turn off power before connecting to cable terminal and copper bar. Make 5 Weld Cable Terminal
weld output terminals. sure that the surfaces of the weld cable
terminal and copper bar are clean. 6 Copper Bar
! Failure to properly connect weld
cables may cause excessive heat 1 Correct Weld Cable Connection Remove supplied nut from weld output ter-
and start a fire, or damage your ma- 2 Incorrect weld Cable Connection minal. Slide weld cable terminal onto weld
chine. output terminal and secure with nut so that
3 Weld Output Terminal weld cable terminal is tight against copper
. Do not place anything between weld 4 Supplied Weld Output Terminal Nut bar.
Connections
To Work 3/4 in.
To Electrode
Ref. 265 690-A
! Turn off welding power source and weld control before making connections.
Flux System
SubArc Interface
SubArc AC/DC 1000/1250
Flux Hopper
Workpiece
Weld Cables
247 480
Electrode
Remote Voltage
Sense Lead
Work
Remote Voltage
Sense Lead
Wire
Drive
BAD
Welding Power
Sense lead is affected by weld Source
current.
Due to voltage drops across work
piece, arc voltage may be low,
causing need for deviation from
standard procedures.
Work
Clamp
Work
Remote Voltage
Sense Lead
Welding Power
BEST
Electrode Source
Sense leads are out of the current Remote Voltage
paths. Sense Lead
Sense leads detect arc voltage ac-
curately.
Wire
Best starts, arcs and most reliable Drive
results.
Work
Clamp
Wire Lead
Drive
Welding Power
Wire Source
Electrode Remote Volt
Drive Sense Leads
BAD
Current flow from lead affects trail Work
sense. Remote Voltage
Current flow from trail affects lead Lead Sense Leads
Trail
sense.
Trail
Neither sense lead picks up the Welding Power
correct work voltage, causing Source
starting and welding arc instability.
Work
Clamp
Trail Lead
Wire
Drive
Lead
Wire Electrode Remote Volt
Drive Sense Leads Welding Power
Source
BAD
Lead Work
Lead sense is affected by weld
Remote Voltage
current from lead. Trail Sense Leads
Trail sense lead is affected by Trail
weld current from trail. Work
Clamp Welding Power
Due to voltage drops across work
piece, arc voltage may be low, Source
Work
causing need for deviation from Clamp
standard procedures.
Trail Lead
Lead
Welding Power
Wire Drive Wire Drive Source
BEST
Electrode Remote
Both sense leads are out of the Volt Sense
current paths. Leads Work Remote Voltage
Both sense leads detect arc volt- Sense Leads
age accurately.
Lead Trail
No voltage drop between lead and Trail
trail sense. Welding Power
Best starts, arcs and most reliable Source
results.
Work
Clamp
Lead
Trail
TO WORK TO WORK
TO ELECTRODE
267 377-A
1 Output Control Switch mote device. Control may be adjusted while welding. Num-
For weld output, place switch in On position. bers on scale are for reference only.
For remote control, connect remote device to
This switch is disabled when a SubArc inter- 4 Power Switch w/Indicator Light
Remote receptacle RC1. Remote control pro-
face is connected to the Remote receptacle vides full range of unit output regardless of 5 Status/Trouble LED
RC1 and powered on, or when a PLC has ac- A/V Adjust control setting. If the output is on See Section 10-1.
tive control through the Modbus RTU connec- before a remote accessory is powered on, the 6 CC/CV Switch
tor. It is also disabled if the power source is in power source will ignore the accessory until
a parallel or tandem configuration and it is not Switch is mounted on electronics baffle.
the output is turned off.
the primary unit. ! Turn Off welding power source and
2 Output On LED 3 A/V (Amperage/Voltage) Adjustment disconnect lockout/tagout input
Control power before removing cover to
! Output is on and weld output studs are change switch position.
energized when LED is lit. Use control to select weld voltage when CC/
CV switch is in the CV position, or amperage Place switch in desired position and install
! Turn Off power before connecting re- when CC/CV switch is in the CC position. cover.
2 3
1 5 4
CC
CV
ON OFF OFF ON 46
OFF OFF OFF ON 47 Table 9-3. Parity Data
ON ON ON OFF 60 DIP1
Parity
OFF ON ON OFF 61 7 8
ON OFF ON OFF 62 ON ON EVEN
8 Common
1 To enable welding control from the Automation Interface, set the “Automation Enable” bit (0x4000) in the Command Flags register
(MODBUS Holding Register 101).
2 Set desired Weld Mode by writing MODBUS Holding Register 105 using look-up table Table 9-6.
3 Obtain Minimum and Maximum values by reading from Input Registers section 300 (See Table 9-8).
4 Set all relevant parameters (MODBUS Holding Registers 102-107) to their desired values. They must be within the minimum and maximum
values read in Step 2. Verify the values are correct by reading Input Registers 102-107.
5 Enable weld output by setting the Output Enable Flag to 1 in the Command Flags register (MODBUS Holding Register 101).
6 Voltage & Current Feedback values can be read from Input Registers section 200 (See Table 9-8).
7 Disable weld output by clearing the Output Enable Flag to 0 in the Command Flags register (MODBUS Holding Register 101).
8 If there is no communication from the MODBUS master for a period greater than one second, the power source will reset all registers to
their default value. Communication can consist of reading or writing.
01 1 Slow Power Circuit Malfunc- Indicates a malfunction in the power circuit. If this code appears
tion on the display, cycle power on power source. Check weld pa-
rameters.
03 3 Slow See 30
04 4 Slow See 40
05 5 Slow Primary Circuit Over Indicates unit has overheated. Unit has shutdown to allow fans to
Temperature lower temperature. Operation will continue after unit is within
normal temperature range.
06 6 Slow See 60
21 2 Quick, 1 Slow Primary Input Line Volt- Indicates input primary line voltage is too low. Primary line volt-
age Malfunction age must be at least 90% of the specified nominal voltage. If this
code appears on the display, have a trained and qualified service
technician check the input voltage.
26 2 Quick, 6 Slow Button Stuck On Sys- Indicates button is stuck on the lower half of the SubArc interface
tem Interface Motor upon start up. Fault will clear when button is released.
Control
30 3 Quick Stuck Contactor On Indicates stuck contactor on the power source. Fault will clear
Power Source when panel switch is set to remote or contactor is released.
32 3 Quick, 2 Slow Coolant Flow Error Indicates coolant input on TB2 in the SubArc Interface is not
connected to common on TB2 (see appropriate Interface OM).
Every
3
Months
Every
3
Months
~:Weld Terminals
Every
6
Months
10-3. Fuse F1
! Disconnect and lockout/tag-
out input power before
checking fuse.
Fuse F1 protect the 400/460 volt
AC winding of transformer T2. If
fuse F1 opens, the welding power
source shuts down.
Open rear panel access door to ac-
cess fuses.
1 Fuse F1
Check F1 and replace if needed,
1 using a fuse of the same rating.
Close and secure rear panel ac-
cess door.
Tools Needed:
3/8 in.
247 479-B
CB1
265 690-A
Trouble Remedy
No weld output; unit completely in- Place line disconnect switch in On position (see Section 5-6).
operative.
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 5-6).
No weld output; pilot light On. Check, repair, or replace system interface.
Unit overheated. Allow unit to cool with fan On (see Section 4-5).
Erratic or improper weld output. Use proper size and type of weld cable (see Section 7-1).
Verify proper connection of volt sense leads (see Section 7-4.B, C).
When using multiple units, make sure all units are properly connected (see Section 7-5), and turned on.
No 24 volts AC output at Remote re- Reset supplementary protector CB1 (see Section 10-4).
ceptacle.
Figure 11.1. Circuit Diagram For Sub Arc AC/DC 1000/1250 Models
OM-265 364 Page 40
. A complete Parts List is available at www.MillerWelds.com
262 522-A
Distributor
Address
City
State Zip
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Contact the Delivering Carrier to: File a claim for loss or damage during
shipment.
For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.
ORIGINAL INSTRUCTIONS − PRINTED IN USA © 2015 Miller Electric Mfg. Co. 2015−01