Вы находитесь на странице: 1из 4

E11F01P48

OneBase™ Twin Diplexer, LTE 800/GSM 900 AISG compatible, dc pass


on GSM 900 port

General Specifications
Product Family CBC89
Modularity 2-Twin
Includes Mounting hardware

Electrical Specifications
Sub
Sub--module 1|2 1|2
Branch 1 2
Port Designation PORT 2 790
790--862 PORT 1 880
880--960
CEL 900
License Band EDD 800
LMR 750
 

Electrical Specifications, Band Pass


Frequency Range 790
790––862 MHz 880
880––960 MHz
Insertion Loss, typical 0.35 dB 0.35 dB
Return Loss, typical 20 dB 20 dB
Isolation, minimum 50 dB 50 dB
Input Power, RMS, maximum 200 W 200 W
3rd Order PIM, typical -155 dBc -155 dBc
3rd Order PIM Test Method Two +43 dBm carriers Two +43 dBm carriers

Product Classification
Brand OneBase™
Product Type Diplexer
 

dc Power/Alarm Electrical Specifications


dc/AISG Pass-through, combiner Branch 1
dc/AISG Pass-through, demultiplexer Branch 1
Lightning Surge Current 3 kA
Lightning Surge Current Waveform 10/350 waveform
 

Electrical Specifications

page 1 of 4
September 6, 2018

©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: August 8, 2018
E11F01P48

Impedance 50 ohm

page 2 of 4
September 6, 2018

©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: August 8, 2018
E11F01P48

Block Diagram

 
 

Mechanical Specifications
RF Connector Interface 7-16 DIN Female
RF Connector Interface Body Style Long neck
Color Gray
Mount Type Pole   |   Wall
Mounting Pipe Diameter 40–140 mm
Mounting Pipe Hardware Band clamps (2)
 

Dimensions
Height 175.0 mm   |   6.9 in
Width 207.0 mm   |   8.1 in
Depth 143.2 mm   |   5.6 in
Weight 7.5 kg   |   16.5 lb
 

Environmental Specifications
Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Ingress Protection Test Method IEC 60529:2001, IP67

page 3 of 4
September 6, 2018

©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: August 8, 2018
E11F01P48

Outline Drawing

Regulatory Compliance/Certifications
Agency Classification
ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system

page 4 of 4
September 6, 2018

©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: August 8, 2018