Вы находитесь на странице: 1из 27

FX ML350p Gen8 Sustaining ER Test Report

Environment Reliability
Test Report

Project Name: ML350p Gen8

Phase Name: Sustaining

Issue Date: 06/23/2014

APPROVED CHECKED PREPARED

BY Andy Wu Tom Bai CC Zhang

DATE 06/23/2014 06/23/2014 06/23/2014

This document contains proprietary and confidential information of Foxconn. All rights and titles
hereto remain with Foxconn. The recipient shall keep this document in strict confidence and shall
use this document in the manner and solely for purposes expressly agreed to by Foxconn. The
recipient shall not disclose or allow access to this document, in whole or in part, by third parties, nor
use it for the benefit of the recipient or third parties. The recipient shall not change this document in
form and substance by any means, including without limitation, decompile, reproduce, revise, and
amend.

FOXCONN CONFIDENTIAL
FX ML350p Gen8 Sustaining ER Test Report
※※ MODIFIED HISTORY ※※

REV. DESCRIPTION DATE REMARK

A Sustaining test 06/23/2014 Temperature:0°C~40°C;


Humidity: 5~95%

FOXCONN CONFIDENTIAL
FX ML350p Gen8 Sustaining ER Test Report
Test Item Summary

Sampling Test
No. Test Item Spec
QTY Stage Result

Temperature:0°C~40°C;
Operating Temperature Humidity: 5~95%;
1 1 Sustaining Pass
and Humidity test Test duration: 4 days;
Test software: ETD Meatgrinder 4.730

FOXCONN CONFIDENTIAL 1
FX ML350p Gen8 Sustaining ER Test Report

Table of Contents
Test Configuration .............................................................................................................. 3

1) Operating Temperature and Humidity test .................................................................... 4


Test Purpose: ................................................................................................................................................ 4
Test Equipment ............................................................................................................................................. 4
Test Samples ................................................................................................................................................. 4
Test Specifications ........................................................................................................................................ 4
Test Conditions.............................................................................................................................................. 4
Test Procedure .............................................................................................................................................. 5
Pass/Fail Criteria: .......................................................................................................................................... 5
Test Result:.................................................................................................................................................... 6
Test Logs: ...................................................................................................................................................... 6

FOXCONN CONFIDENTIAL 2
FX ML350p Gen8 Sustaining ER Test Report
Test Configuration

Name Vendor Description HP P/N Vendor P/N

CPU Intel E5-2609v2 QEQ9


Memory Hynix 4GB 2Rx8 PC3L-12800E-11 713751-071
M/B Foxconn ML350p Gen8 M/B XC 635678-001
HP 300GB 6G SAS 10K 2.5in SC ENT
HDD Seagate 9TE066-035
HDD,64MB
ODD HP SATA,16X,DVDRW JB ISSG/HL 575781-5M5
1GB FBWC for P-Series Smart
Card HP 660099-001
Array
DPS-460EB
PSU Delta 460W CS Gold Ht Plg Pwr Supply 499250-101
A
BIOS P72-02/10/2014

FOXCONN CONFIDENTIAL 3
FX ML350p Gen8 Sustaining ER Test Report

1) Operating Temperature and Humidity test


Test Purpose:
To verify that the operational unit under test (UUT) and its components do not suffer damage or
loss of data when subjected to elevated or reduced humidity and temperature conditions.

Test Equipment
1) Unit Under Test (UUT)
2) Temperature/Humidity Chamber
3) Test Software: OS Window 2012, ETD Meatgrinder 4.730.
Note: Test site is FXN TJ R&D lab.

Test Samples
1. The UUT configuration shall be approved by HP prior to testing.
2. Multiple configurations may be required to be tested, depending on the project’s complexity and
goals. Each configuration shall be tested separately.
Note: Serial number PBYFTXCTM2A00F

Test Specifications
The unit shall be fully functional from 5 to 95% relative humidity, 28℃ maximum wet bulb
temperature, (non-condensing) across the operating temperature range of 0℃ to 40℃

Test Conditions
1. Run ETD Meatgrinder 4.730;
2. Test duration: 4 cycles.

Figure 1: Operational Temperature and Humidity profile.

FOXCONN CONFIDENTIAL 4
FX ML350p Gen8 Sustaining ER Test Report

Test Procedure
1. Begin with the UUT powered off
2. Log all UUT configuration information, software used, revision level, etc. for report
generation once testing is complete.
3. Place UUT in Humidity test chamber.
4. Power UUT on and launch Meatgrinder using the approved configuration file.
5. Allow Meatgrinder to run a minimum of twenty minutes.
6. Halt Meatgrinder and examine the log file for any failures or warnings.
7. If any failures or warnings are logged, they must be documented in the test report and
corrected before the test is continued.
8. Save the Meatgrinder log file for attachment to the report.
9. If the unit passed the pre-test in Steps 4 through 7, proceed to Step 10.
10. Program the test chamber per the Operational Temperature and Humidity profile as above.
11. Complete the Operational Temperature and Humidity test as shown above. The standard
test duration shall be four 24-hour cycles.
12. Launch Meatgrinder using the approved configuration file.
13. Allow Meatgrinder to run a minimum of twenty minutes.
14. Halt Meatgrinder and examine the log file for any failures or warnings.
15. If any failures or warnings are logged, they must be documented in the test report.
16. Save the Meatgrinder log file for attachment to the report.

Pass/Fail Criteria:
1. During and after the Operational Temperature and Humidity test, the UUT must perform
functionally as intended.
2. No cosmetic damage to the UUT is allowed.

FOXCONN CONFIDENTIAL 5
FX ML350p Gen8 Sustaining ER Test Report
Test Picture:
During Test

Test Result:
Test Software Visual Check Functional Check Test Result
ETD Meatgrinder 4.730 Pass Pass Pass

Test Logs:
ETD Logs

logs.zip

FOXCONN CONFIDENTIAL 6

Вам также может понравиться