pH ELECTRODES

BULB ELECTRODES

- for measurements of liquids


- for general purposes
- minimum sample volume required: 7 mL

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C)

OP-0718P Standard „S“ 0 ... 14 ± 0.05 5 ... 60


OP-0719P GoldGlass „GG“ 0 ... 14 ± 0.03 5 ... 60

SURFACE ELECTRODE

- for measurements of surface pH


of wet samples

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C)

OP-0715P Standard „S“ 0 ... 14 ± 0.05 5 ... 60

CONICAL ELECTRODE

- for measurements of gel-like


samples, e.g. food
- minimum sample volume required: 7 mL

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C)

OP-0714P Standard „S“ 0 ... 14 ± 0.05 5 ... 60

BULB ELECTRODE

- with standard cone


- for measurements in liquids e.g. in flasks
- minimum sample volume required: 7 mL

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C)

OH-0931P Coned „S“ 0 ... 14 ± 0.05 5 ... 60

-1-
COMBINATION pH ELECTRODES

BULB ELECTRODES

- for measurements of liquids


- for general purposes
- minimum sample volume required: 2 mL

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C) Reference solution

OP-0808P Standard „S“ 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1


OP-0868P Low outflow rate „S“ 0 ... 14 ± 0.05 5 ... 60 FIL - SC - 1
OP-0878P Liquid junction potential free „S“ 0 ... 14 ± 0.04 5 ... 60 FIL - DPM
OP-0888P GoldGlass „GG“ 0 ... 14 ± 0.03 5 ... 60 FIL - Cl - 1

MICRO BULB ELECTRODES

- for measurements of liquids of small volume


- for general purposes
- minimum sample volume required: 0.2 mL

Denomination Reproducibility Temperature range


Type (Character) L (mm) pH range (pH) (°C) Reference solution

OP-0823P Standard „S“ 70 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1


OP-0824P Standard „S“ 110 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1
OP-0825P Standard „S“ 200 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1
OP-0826P Standard „S“ 50 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1

SURFACE ELECTRODE

- for measurements of surface pH


of wet samples

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C) Reference solution

OP-0801P Standard „S“ 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1

-2-
COMBINATION pH ELECTRODES

MICRO BULB ELECTRODE

- with standard cone


- for measurements in small volumes
- minimum sample volume required: 0.2 mL

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C) Reference solution

OP-0864P Standard „S“ 0 ... 14 ± 0.05 5 ... 60 FIL - Cl - 1

VAGINA ELECTRODE

- for special medical purposes

Denomination Reproducibility Temperature range


Type (Character) pH range (pH) (°C) Reference solution

OP-0862P Standard „S“ 0 ... 14 ± 0.05 5 ... 60 FIL - SC - 1

STERILIZABLE ELECTRODES

- for measurements of liquids e.g. in


fermentors, up to 6 bars built in a
pressure-proof case

Denomination Reproducibility Temperature range Reference Type of


Type (Character) L (mm) pH range (pH) (°C) solution electrode case

RA-0901P Standard „S“ 115 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1901
RA-0902P Standard „S“ 145 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1902
RA-0903P Standard „S“ 245 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1903
RA-0904P Standard „S“ 345 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1904
RA-0905P Standard „S“ 445 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1905
RA-0906P Standard „S“ 545 0 ... 14 ± 0.05 5 ... 130 FIL - SC - 1 RA-1906

-3-
ION-SELECTIVE ELECTRODES

ION-SELECTIVE ELECTRODES

- solid state type, sensor of


hemispherical shape
- minimum sample volume required: 7 mL

Denomination Measuring range Reproducibility


Type (Character) (mol/L) Interfering ions* (mV)

OP-Ag-0711P Silver ion-selective 100 ....... 10-5 Hg2+ ±1


OP-Br-0711P Bromide ion-selective 100 ....... 10-6 SCN-, I-, CN-, S2- ± 1.5
OP-Cl-0711P Chloride ion-selective 100 ....... 10-5 Br-, I-, CN-, S2- ± 1.5
10-2 ....... 10-6
OP-CN-0711P Cyanide ion-selective I-, S2- ±1
100 ....... 10-6
OP-F-0711P Fluoride ion-selective OH- ±1
100 ....... 10-6
OP-I-0711P Iodide ion-selective 10-1 ....... 10-7 Br-, S2- ± 1.5
OP-S-0711P Sulphide ion-selective 100 ....... 10-6 Hg2+ ± 1.5
OP-SCN-0711P Thiocyanate ion-selective 10-1 ....... 10-6 I-, S2- ± 1.5

Temperature range Recommended Recommended salt Recommended ionic


Type pH range (°C) reference electrode bridge solution strength adjuster

OP-Ag-0711P 2 ...... 9 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 IS - NO3 - 2


OP-Br-0711P 2 .... 12 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 IS - NO3 - 2
OP-Cl-0711P 3 .... 10 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 IS - NO3 - 2
OP-CN-0711P 11 .... 13 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 *
OP-F-0711P 5 ...... 8 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 TISAB
OP-I-0711P 3 .... 12 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 IS - NO3 - 2
OP-S-0711P 13 .... 14 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 *
OP-SCN-0711P 2 .... 12 0 ... 80 OP-0820P, OP-0871P FIL - NO3 - 1 IS - NO3 - 2

* For further information see the manual of the electrode.

-4-
ION-SELECTIVE ELECTRODES

ION-SELECTIVE ELECTRODES

- disk-shape neutral carrier


membrane sensors
- minimum sample volume required: 7 mL

Denomination Measuring range Reproducibility


Type (Character) (mol/L) Interfering ions* (mV)

OP-Ca-0711P-S Calcium ion-selective 100 ....... 10-5 Mg2+ , Ca2+ ± 1.5


OP-K-0711P-S Potassium ion-selective 100 ....... 10-6 Rb+, Cs+, NH4+ ± 1.5
OP-NH4-0711P-S Ammonium ion-selective 100 ....... 10-6 K+, H+, Li+ ± 1.5
OP-NO3-0711P-S Nitrate ion-selective 100 ....... 10-5 I-, Cl-, Br-, NO2- ± 1.5

Temperature range Recommended Recommended Recommended ionic


Type pH range (°C) reference electrode salt bridge solution strength adjuster

OP-Ca-0711P-S 3 .... 11 0 ... 40 OP-0820P, OP-0871P FIL - Ca - 2 *


OP-K-0711P-S 3 .... 10 0 ... 40 OP-0820P, OP-0871P FIL - NO3 - 2 *
OP-NH4-0711P-S 3 ...... 8 0 ... 40 OP-0820P, OP-0871P FIL - NaOAc - 1 *
OP-NO3-0711P-S 3 ...... 9 0 ... 40 OP-0820P, OP-0871P FIL - Na2SO4 - 1 *

ION-SELECTIVE ELECTRODES

- glass type, bulb shape


- minimum sample volume required: 7 mL

Denomination Measuring range Reproducibility


Type (Character) (mol/L) Interfering ions* (mV)

OP-Na-0711P Sodium ion-selective 100 ....... 10-6 K+, NH4+ ±2

Temperature range Recommended Recommended Recommended ionic


Type pH range (°C) reference electrode salt bridge solution strength adjuster

OP-Na-0711P pH ≥ pNa + 3 0 ... 60 OP-0820P, OP-0871P FIL - NO3 - 1 *

* For further information see the manual of the electrode.

-5-
REDOX ELECTRODES

SHEET ELECTRODES

- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OP-0612P Platinum sheet 0 ... 100


OP-0614P Gold sheet 0 ... 100

PLATINUM POINT ELECTRODE

- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OH-0961P Platinum point 0 ... 100

PLATINUM DISK ELECTRODE

- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OH-0963P Platinum disk 0 ... 100

-6-
REDOX ELECTRODES

GRAPHITE ELECTRODE

- cylinder shape sensor


- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OP-C-0711P Potentiometric 0 ... 80

PLATINUM NEEDLE ELECTRODE

- with standard cone


- for measurements of liquids e.g. in flasks
- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OH-0936P Platinum needle with standard cone 0 ... 100

PLATINUM SPHERE ELECTRODE

- combination type
- reference electrode: Ag/AgCl
- minimum sample volume required: 2 mL

Type Denomination (Character) Temperature range (°C) Reference solution

OP-0622P Combination platinum sphere 0 ... 100 FIL - Cl - 1

-7-
REFERENCE ELECTRODES

ELECTRODES WITH CERAMIC


JUNCTION

- for use with half-cells


- for general purposes
- minimum sample volume required: 7 mL
DPM = liquid junction potential free

Secondary Temperature range Recommended


Type Denomination (Character) electrode (°C) reference solution

OP-0830P Calomel Hg/Hg2 Cl2 0 ... 70 Saturated KCl *


OP-0831P Silver/silver chloride Ag/AgCl 0 ... 80 FIL - Cl - 1 *
OP-0870P DPM Silver/silver chloride Ag/AgCl 0 ... 80 FIL - DPM *
OP-0872P DPM Calomel Hg/Hg2 Cl2 0 ... 70 FIL - DPM *
OP-0874P Small outflow rate silver/silver chloride Ag/AgCl 0 ... 80 FIL - SC - 1 ***

ELECTRODE WITH STANDARD


CONE

- with ceramic junction


- for use with half-cells
- for measurements of liquids in flasks
- minimum sample volume required: 7 mL

Secondary Temperature range


Type Denomination (Character) electrode (°C) Reference solution

OH-0933P Calomel with standard cone Hg/Hg2 Cl2 0 ... 70 FIL - Cl - 1 *

Outflow rate at 5 cm difference of solution levels: * 0.1-1 mL/day


** 1 - 3 mL/day
*** 0.01 - 0.1 mL/day

-8-
REFERENCE ELECTRODES

ELECTRODE WITH SALT BRIDGE

- with ceramic and cone junctions


- for use with half-cells, mainly with
ion-selective electrodes
- minimum sample volume required: 7 mL

Secondary Temperature range


Type Denomination (Character) electrode (°C) Reference solution

OP-0820P Silver/silver chloride Ag/AgCl 0 ... 80 FIL - Cl - 1 **

LIQUID JUNCTION POTENTIAL FREE


ELECTRODES WITH SALT BRIDGE

- with ceramic junction


- for use with half-cells
- for high precision measurements
- minimum sample volume required: 7 mL
DPM = liquid junction potential free

Secondary Temperature range


Type Denomination (Character) electrode (°C) Reference solution

OP-0871P DPM Silver/silver chloride Ag/AgCl 0 ... 80 FIL - DPM *


OP-0873P DPM Calomel Hg/Hg2 Cl2 0 ... 70 FIL - DPM *

Outflow rate at 5 cm difference of solution levels: * 0.1-1 mL/day


** 1 - 3 mL/day
*** 0.01 - 0.1 mL/day

-9-
GAS ELECTRODES

POTENTIOMETRIC ELECTRODES

- for measurements of gases dissolved


in liquids
- for general purposes, with fixed cable
- with gas permeable membranes
- minimum sample volume required: 4 mL

Measuring Reproducibility Temperature range


Type Denomination (Character) range (mV) (°C)

OP-NH3-7113-S Ammonia selective 100 ...... 10-6 mol/l ± 1.5 5 ... 60

AMPEROMETRIC ELECTRODE

- for measurements of oxygen dissolved


in liquids
- for general purposes
- with oxygen permeable membrane
- minimum sample volume required: 4 mL

Measuring range Reproducibility Temperature range


Type Denomination (Character) (rel. %) (%) (°C)

RA-0950P-S Oxygen selective 0 ... 400 ±1 5 ... 70

- 10 -
OTHER ELECTRODES AND SENSORS

PLATINUM ELECTRODE

- double ring with standard cone


- for biamperometric measurements
- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OP-0001P With standard cone, platinum double ring 0 ... 100

PLATINUM ELECTRODE

- double needle, with standard cone


- for bipotentiometric measurements
- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OH-0938P With standard cone, double needle platinum 0 ... 100

GRAPHITE ELECTRODE

- with graphite cylinder


- for voltammetric measurements
- minimum sample volume required: 7 mL

Type Denomination (Character) Temperature range (°C)

OH-VM-0711P Voltammetric 0 ... 100

- 11 -
OTHER ELECTRODES AND SENSORS

TEMPERATURE SENSOR

- for instruments with temperature


compensation
- minimum sample volume required: 2 mL
- sensor: AD 590 IC

Type Denomination (Character) Temperature range (°C)

OP-0003P In metal case 0 ... 60

TEMPERATURE SENSOR

- for instruments with temperature


compensation
- minimum sample volume required: 2 mL
- sensor: thermistor

Type Denomination (Character) Temperature range (°C)

OP-0005P In glass casing 0 ... 100

- 12 -
CONDUCTOMETRIC ELECTRODES

BELL-SHAPED ELECTRODE

- for measurements of the conductivity of liquids


- for general purposes
- minimum sample volume required: 10 mL

Temperature range
Type Denomination (Character) Cell constant (cm- 1) (°C)

OK-0902P Three rings as plates 0.7 ± 15 % 0 ... 100

ELECTRODE WITH SHEET PLATES

- for measurements of the conductivity of liquids


- for general purposes
- minimum sample volume required: 4 mL

Temperature range
Type Denomination (Character) Cell constant (cm- 1) (°C)

OK-0907P Facing plates 1.0 ± 10 % 0 ... 100

ELECTRODE WITH SHEET PLATES

- for measurements of the conductivity of liquids


- for measurements of solutions of low
conductivity
- minimum sample volume required: 8 mL
Temperature range
Type Denomination (Character) Cell constant (cm- 1) (°C)

OK-0908P Transversal plates 10 ± 10 % 0 ... 100

FLOW THROUGH ELECTRODE

- for measurements of the conductivity of liquids


- for measurements of flowing systems

Temperature range
Type Denomination (Character) Cell constant (cm- 1 ) (°C)

OK-0909P Three rings as plates 1.0 ± 15 % 0 ... 100

- 13 -