Академический Документы
Профессиональный Документы
Культура Документы
12
Replaces: 12.09
1/52
A10V(S)O
(US-Version)
Contents Features
Type code for standard program 2 –– Variable pump in axial piston swashplate design for hydrosta-
tic drives in an open circuit
Technical data 4
–– The flow is proportional to the drive speed and the displace-
DG – Two-point control, directly operated 10
ment.
DR – Pressure control 11
–– The flow can be steplessly varied by adjustment of the
DRG – Pressure control, remotely operated 12 swashplate angle.
DFR/DFR1 – Pressure and flow control 13 –– 2 case drain ports
DFLR – Pressure, flow and power control 14 –– Excellent suction characteristics
ED – Electro-hydraulic pressure control 15 –– Low noise level
ER – Electro-hydraulic pressure control 16 –– Long service life
Dimensions size 18 to 140 18 –– Favorable power/weight ratio
Dimensions through drive 42 –– Versatile controller range
Summary mounting options 45 –– Short control time
Combination pumps A10VO + A10VO 46 –– The through drive is suitable for adding gear pumps and axial
piston pumps up to the same size, i.e., 100% through drive.
Connector for solenoids 47
Installation instructions 48
General instructions 52
2/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
Operation mode
03 Pump, open circuit O
Size (NG)
04 Geometric displacement, see table of values on pages 6 and 7 18 28 45 71 100 140
Control device
Two-point control, directly operated l l l l l l DG
Pressure control l l l l l l DR
with flow control, hydraulic
Series
06 Series 3, Index 1 31
Direction of rotation
Viewed on drive shaft clockwise R
07
counter clockwise L
Seals
08 FKM (fluor-caoutchouc) V
1) See RE 92709
2) The following must be taken into account during project planning:
Excessive current levels (I > 1200 mA with 12 V or I > 600 mA with 24 V) to the ER solenoid can result in undesired increase
of pressure which can lead to pump or system damage:
- Use Imax current limiter solenoids.
- A sandwich plate pressure reducing valve can be used to protect the pump in the event of overflow.
An accessory kit with sandwich plate pressure reducing valve can be ordered from Rexroth under part number R902490825.
Technical data
Hydraulic fluid Notes on the choice of hydraulic fluid
Before starting project planning, please refer to our data In order to select the correct hydraulic fluid, it is necessary to
sheets RE 90220 (mineral oil), RE 90221 (environmentally know the operating temperature in the reservoir (open circuit)
acceptable hydraulic fluids) and RE 90222 (HFD hydraulic in relation to the ambient temperature.
fluids) for detailed information regarding the choice of hydraulic
The hydraulic fluid should be selected so that within the ope-
fluid and application conditions.
rating temperature range, the viscosity lies within the optimum
If environmentally acceptable hydraulic fluids are being used, range (nopt), see shaded section of the selection diagram. We
the limitations regarding technical data and other seals must recommend to select the higher viscosity grade in each case.
be observed. Please contact us.
Example: at an ambient temperature of X °F (°C) the operating
Operating viscosity range temperature is 140 °F (60 °C). In the optimum operating vis-
cosity range (nopt; shaded area) this corresponds to viscosity
For optimum efficiency and service life we recommend that the
grades VG 46 resp. VG 68; VG 68 should be selected.
operating viscosity (at operating temperature) be selected in
the range Important:
nopt = opt. operating viscosity 80 - 170 SUS (16 ... 36 mm /s) 2 The case drain temperature is influenced by pressure and input
speed and is always higher than the reservoir temperature.
referred to reservoir temperature (open circuit). However, at no point in the component may the temperature
Limits of viscosity range exceed 239 °F (115 °C). The temperature difference specified
on the left is to be taken into account when determining the
For critical operating conditions the following values apply: viscosity in the bearing.
nmin = 60 SUS (10 mm2/s) If the above conditions cannot be met, due to extreme opera-
short-term (t ≤ 1 min) ting parameters please contact us.
at max perm. case drain temperature of 239 °F
(115 °C). Filtration of the hydraulic fluid
The finer the filtration the better the cleanliness level of the hyd-
Please also ensure that the max. case drain temperature raulic fluid and the longer the service life of the axial piston unit.
of 239 °F (115 °C) is not exceeded in localized areas (for
instance, in the bearing area). The fluid temperature in the In order to guarantee the functional reliability of the axial piston
bearing area is unit it is necessary to carry out a gravimetric evaluation of the
approx. 7 °F (5 K) higher than the average case drain tempe- hydraulic fluid to determine the particle contamination and the
rature. cleanliness level according to ISO 4406. A cleanliness level of
at least 20/18/15 must be maintained.
nmax = 7500 SUS (1600 mm2/s) At very high hydraulic fluid temperatures (195 °F (90 °C) to ma-
short-term (t ≤ 1 min) ximum 239 °F (115 °C)), a cleanliness level of at least 19/17/14
on cold start according to ISO 4406 is necessary.
(p ≤ 435 psi (30 bar), n ≤ 1000 rpm, tmin -13 °F
If the above cleanliness levels cannot be maintained, please
(-25 °C))
contact us.
Depending on the installation situation, special measures are
necessary at temperatures between -40 °F (-40°C) and -13 °F
(-25°C). Please contact us.
For detailed information on operation with low temperatures
see data sheet RE 90300-03-B.
Selection diagram
-40° -4° 32° 68° 104° 140° 176° 212° °F
-40° -20° 0° 20° 40° 60° 80° 100° °C
7400 1600 1600 7400
4600 1000
3000 600
2000 400
Viscosity n [mm2/s]
VG 68
1000
VG
VG 22
VG 32
VG 46
200
10
500 100
0
300 60
200 40 36 170
nopt
100 20
80 16 80
60 10
Technical data
Operating pressure range
(when using mineral oil)
Time t t2
Single operating period t1 tn
Pressure p
Note
Exceeding the maximum or falling below the minimum permissible values can lead to a loss of function, a reduction in operational
service life or total destruction of the axial piston unit. We recommend to check the loading through tests or calculation / simulati-
on and comparison with the permissible values.
Calculation of characteristics
Note
Exceeding the maximum or falling below the minimum permissible values can lead to a loss of function, a reduction in operational
service life or total destruction of the axial piston unit. We recommend to check the loading through tests or calculation / simulati-
on and comparison with the permissible values.
Sizes 45, 71, 100 and 140 are optionally available in high-speed version.
External dimensions are not affected by this option.
8/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
Technical data
Permissible radial and axial loading on the drive shaft
Size NG 18 28 45 71 100 140
Radial force maximum Fq
at a/2
lbf 80 270 340 427 517 630
Fq max
a/2 a/2 (N) (350) (1200) (1500) (1900) (2300) (2800)
a
T1 T2
TE
1. Pumpe
1st pump 2.
2ndPumpe
pump
TD
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 9/52
Technical data
Drive power and flow
Operating material:
Hydraulic fluid ISO VG 46 DIN 51519, t = 122 °F (50 °C)
Size 18 Size 100
_ _ _ _ n = 1800 rpm _ _ _ _ n = 1800 rpm
______ n = 3300 rpm ______ n = 2000 rpm
(L/min) gpm (kW) HP
(200) (100)
(L/min) gpm (kW) HP 50
(180) (90) 120
(80) 20 (40)
(160) qv (80)
40
Flow qV
(60) (30) 40 100
(140) (70)
Drive power P
Drive power P
qv Pqv max
Flow qV
(40) 10 (20)
20 (120) Pqv max (60) 80
(20) Pqv zero (10) 30
(100) (50)
0 60
500 1000 1500 2000 2500 3000 3500 4000psi 0 (80) (40)
20
0 (50) (100) (150) (200) (250) (280)(bar) (60) (30) 40
Operating pressure (40) 10 Pqv zero (20)
20
(20) (10)
Size 28
0 500 1000 1500 2000 2500 3000 3500 4000 psi 0
_ _ _ _ n = 1800 rpm 0 (50) (100) (150) (200) (250)(280)(bar)
Drive power P
(40) 10 (20)
20 ______ n = 1800 rpm
(20) Pqv zero (10)
(L/min) gpm (kW) HP
0 500 1000 1500 2000 2500 3000 3500 4000psi 0 (260) (130)
0 (50) (100) (150) (200) (250)(280)(bar) (240) qv (120) 160
Operating pressure 60
(220) (110)
140
(200) (100)
Flow qV
Drive power P
50
Size 45 (180) (90) 120
(80)
_ _ _ _ n = 1800 rpm (160)
40 100
(140) Pqv max (70)
______ n = 2600 rpm (120)
30
(60) 80
Size 71
_ _ _ _ n = 1800 rpm
______ n = 2200 rpm
(100) (50)
Flow qV
60
(80) 20 Pqv max (40)
(60) (30) 40
(40) 10 Pqv zero
(20)
20
(20) (10)
psi (bar)
1720 (120)
1455 (100)
Req. control pressure pst
L1 S
725 (50)
Port for
B Service line
psi 0 7251020 2040 3060 4000
(bar) (50)(70) (140) (210) (280) S Suction line
Operating pressure pB L, L1 Case drain (L1 plugged)
X Pilot pressure
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 11/52
DR – Pressure control
The pressure control limits the maximum pressure at the pump Circuit diagram, sizes 18 to 100
output within the pump control range. The variable pump only
supplies as much hydraulic fluid as is required by the consu
mers. If the operating pressure exceeds the pressure setpoint
set at the integrated pressure valve, the pump will adjust
towards a smaller displacement and the control deviation will L B
be reduced. The pressure can be set steplessly at the control
valve.
Static characteristic
(at n1 = 1800 rpm; tfluid = 122 °F (50 °C))
L1 S
365 (25)
Control data
Hysteresis and repeatability ∆p_______ maximum 45 psi (3 bar)
Pressure rise, maximum
NG 18 28 45 71 100 140
∆p psi 60 60 90 115 145 175
(bar) (4) (4) (6) (8) (10) (12)
Control fluid consumption______ max. approx. 0.8 gpm (3 l/min)
Flow losses at qVmax see page 9.
12/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
Static characteristic
(at n1 = 1800 rpm; tfluid = 122 °F (50 °C))
Hysteresis / pressure rise ∆pmax
psi (bar)
L1 S
4000 (280)
Circuit diagram, size 140
Operating pressure pB
290 (20)
1) In order to prevent damage to the pump and the system, L, L1 Case drain (L1 plugged)
this setting range is the permissible setting range and must X NG 18 to 100 Pilot pressure
not be exceeded. with adapter
The range of possible settings at the valve are greater.
X NG 140 Pilot pressure
without adapter
Control data
Hysteresis and repeatability ∆p_______ maximum 45 psi (3 bar)
Pressure rise, maximum
NG 18 28 45 71 100 140
∆p psi 60 60 90 115 145 175
(bar) (4) (4) (6) (8) (10) (12)
Control fluid consumption_____max. approx. 1.2 gpm (4.5 l/min)
Flow losses at qVmax see page 9.
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 13/52
Setting range1)
L1 S
X
Flow qv [gpm (l/min)]
S Suction line
L, L1 Case drain (L1 plugged)
X Pilot pressure
Control data
Speed n [rpm]
Data for pressure control DR, see page 11.
Maximum flow deviation measured with drive speed
n = 1500 rpm.
Differential pressure ∆p
NG 18 28 45 71 100 140
Standard setting: 200 to 320 psi (14 to 22 bar). ∆qv max gpm 0.24 0.26 0.48 0.75 1.06 1.60
If another setting is required, please state in clear text. (l/min) (0.9) (1.0) (1.8) (2.8) (4.0) (6.0)
Relieving the load on port X to the reservoir results in a zero
stroke ("standby") pressure which lies about 15 to 30 psi (1 to Control fluid consumption DFR___ max. approx. 0.8 to 1.2 gpm
2 bar) higher than the differential pressure ∆p. System influen- (3 to 4.5 l/min)
ces are not taken into account. Control fluid consumption DFR1____maximum approx. 0.8 gpm
(3 l/min) Volume flow loss at qVmax, see page 9.
14/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
X Not included
psi (bar) in the delivery
4350 (300) Maximum contents
4000 (280) power curve
3600 (250)
Operating pressure pB
2900 (200)
L B
2200 (150)
1450 (100)
Maximum
725 (50) power curve
0 (0)
∆qV
L1 S
Torque T [lb-ft (Nm)]
(see table
on page 13)
Circuit diagram, size 140
X
Not included
in the delivery
contents
0 100
Volume flow qv [%]
L B
Control data
Beginning of control_ ____________________ 725 psi (50 bar)
Control fluid consumption__ maxi. approx. 1.45 gpm (5.5 l/min)
Flow loss at qv max, see page 9.
Port for
B Service line
S Suction line
L, L1 Case drain (L1 plugged) L1 S
X Pilot pressure
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 15/52
Standby
This causes an increase or decrease in the pump swivel angle 350 (24)
(flow) in order to maintain the electrically set pressure level. 320 (22)
The pump thus only delivers as much hydraulic fluid as the 290 (20)
consumers can take. The desired pressure level can be set 260 (18)
steplessly by varying the solenoid current. 230 (16)
200 (14)
When the solenoid current signal drops towards a zero value, (bar) (120) (140) (160) (180) (200) (220) (240) (260) (280)
the maximum output pressure is limited to pmax by an adjustable psi 1750 2000 2350 2700 2900 3200 3500 3700 4000
hydraulic pressure cut-off (secure fail safe function in case of a
Maximum pressure setting
loss of power e.g. for use as fan drives).
The response time characteristic of the ED-control was Circuit diagram ED..
optimized for the use as a fan drive system.
When ordering, state the type of application in clear text.
of control L B
Max. adjustable
control pressure
2050 (140)
Setting range
3600 (250) L1 S
Max. adjustable
control pressure
2200 (150)
Port for
Min. B Service line
725 (50) adjustable
control pressure S Suction line
0 (0) L, L1 Case drain (L1 plugged)
0 1
Amperage
I/Imax
4000 (280)
Limiting current 1.54 A 0.77 A
Operating pressure p
Notes
18/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
)
3.27 (83)
(11
43
X L
0.
ISO 3019-1
X
2.48 (63)
45° 45°
(Ø82.55 -0.054 )
DIA 3.2500
3.2479
6)
0
(6
60
2.52 (64)
2.48 (63)
2.72 (69)
2.
0.45 4.19 (106.4)
(11.5) 1.69 (43) L1 5.98 (152)
S
5.71 (145) 4.29 (109)
7.68 (195) 4.96 (126)
View V View W
0.87 (22.2)
B S
2.06 (52.4)
DIA 0.98
(Ø20) 1.87 (47.6)
(Ø25)
DIA 0.79
1.03
(26.2)
Ports
Designation Port for Standard Size1) Max. press. State
[psi /(bar)]2)
B Service line, SAE J518 3/4 in 5100 (350) O
fastening thread ASME B1.1 3/8-16 UNC-2B; 0.79 (20) deep
S Suction line, SAE J518 1 in 145 psi (10) O
fastening thread ASME B1.1 3/8-16 UNC-2B; 0.79 (20) deep
L Case drain fluid ISO 119263) 9/16-18UNF-2B; 0.47 (12) deep 30 (2) O4)
L1 Case drain fluid ISO 119263) 9/16-18UNF-2B; 0.47 (12) deep 30 (2) X4)
X Pilot pressure ISO 119263) 7/16-20UNF-2B; 0.45 (11.5) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2283) G 1/4 in; 0.47 (12) deep 5100 (350) O
1) For the maximum tightening torques the general instructions on page 52 must be observed.
2) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute
3) The spot face can be deeper than as specified in the standard
4) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 19/52
1.18 (30)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.55 (14)
0.94 (23.8)
0.55 (14)
0.20 (5)
0.20 (5)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Splines according to ANSI B92.1a, run out of spline is a deviation from standard
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 52 must be observed
5) Coupling axially secured, e.g. with a clamp coupling or radially mounted clamping screw
20/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
X
X
0.98
3.50 (89) 4.96 (126)
3.82 (97)
to flange surface
7.24 (184)
to flange surface Valve mounting for
Valve mounting for
5.08 (129) ccw rotation
max. 4.33 (110)
ccw rotation
5.51 (140)
X
1.57 (40)
X
X
4.29 (109)
4.96 (126) 4.96 (126)1)
1) ER7.: 6.34 in (161 mm) if using a sandwich plate pressure reducing valve.
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 21/52
Port plate 62
V Valve mounting for
ccw rotation 4)
5.47 (139)
B (7
91
)
0.37 (9.5) 3.54 (90)
(14
0.25 (6.3) 2.
1.57 (40)
Flange X
05
IA
ISO 3019-1
D
45°
3.15 (80)
45°
X
)
-0.054
DIA 4.0000
3.9979
0
(Ø101.6
6.8
5(
2.91 (74)
3.15 (80)
Ø1
74
)
0.55 (14)
L1 S 5.75 (146)
1.57 (40) 6.46 (164)
6.46 (164)
7.64 (194) 3.29 (83.5) 4.68 (119)
5.35 (136)
W
Detail V Detail W
0.87 (22.2)
2.31 (58.7) S
1.26 (Ø32)
B
1.87 (47.6)
DIA 0.79
1.19 (30.2)
(Ø20)
View Z
Valve mounting for
Port plate 61 ccw rotation
2.87 (73)
1.87 (47.6)
0.79
0.87 (22.2)
0.25 (6.3) L
Flange
ISO 3019-1 X
1.77 (45)1.77 (45)
1.69 (43)
(Ø101.6 -0.054 )
DIA 4.0000
3.9979
0
Z
3.11 (79)
1.19 (30.2)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.63 (16)
0.63 (16) 0.55 (14)
0.20 0.20 (5)
0.20 (5)
(5)
0.55 (14)
0.20 (5)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Spline according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 52 must be observed.
Ports
Designation Port for Standard Size5) Max. press. State
[psi (bar)]6)
B Service line, SAE J518 3/4 in 5100 (350) O
fastening thread ASME B1.1 3/8-16 UNC-2B; 0.79 (20) deep
S Suction line, SAE J518 1 1/4 in 145 (10) O
fastening thread ASME B1.1 7/16-14 UNC-2B; 0.94 (24) deep
L Case drain fluid ISO 119267) 3/4-16 UNF-2B; 0.55 (14) deep 30 (2) O8)
L1 Case drain fluid ISO 119267) 3/4-16 UNF-2B; 0.55 (14) deep 30 (2) X8)
X Pilot pressure ISO 119267) 7/16-14UNC-2B; 0.45 (11.5) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2287) G 1/4in; 0.47 (12) deep 5100 (350) O
5) For the maximum tightening torques the general instructions on page 52 must be observed.
6) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute.
7) The spot face can be deeper than as specified in the standard.
8) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 23/52
View Z
Valve mounting for
Valve mounting for to flange surface ccw rotation
ccw rotation 6.22 (158)
+0.4
Ø25 +0.4
0.12 (3)
L
Ø25
X
Z
0.12 (3)
3.11 (79)
0.98
DIA 1.00
0.98
DIA1.00
DR DR
Pressure control, port plate 61 Pressure control, port plate 62
View Z
X
Z
8.90 (226)
5.35 (136)
to flange surface
DRG DRG
Pressure control, remotely operated, port plate 61 Pressure control, remotely operated, port plate 62
View Z
Valve mounting for Valve mounting for
to flange surface
ccw rotation ccw rotation
2.91 (74) 5.08
(129) X
max. 4.33 (110)
max. 4.45 (113)
1.57 (40)
X
X
Z
1.69 (43)
1.57 (40)
max.4.33 (110)
max. 4.45 (113)
5.51 (140)
5.63 (143)
5.35 (136)2)
8.86 (225)1)
ER7.: 10.24 in (260 mm) when using a sandwich plate pressure reducing valve.
1)
ER7.: 6.83 in (170.9 mm) when using a sandwich plate pressure reducing valve.
2)
For details of connection options and drive shafts, see also pages 21 and 22
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 25/52
3)
55
0.25 (6.3) 3.78 (96) 0.
(8
27
Flange I A
L X D 14)
1.57 (40)
ISO 3019-1 L
(Ø
3.54 (90)
45° 45°
X
(Ø101.6 -0.054 )
4.0000
3.9979
0
3.17 (80.5)
DIA
3.54 (90)
0.56 (14.3) L1
5.75 (146)
1.77 (45)
7.24 (184) 7.24 (184)
8.62 (219) 3.68 (93.5) 5.08 (129)
5.75 (146)
W
Detail V View W
B
S
DIA 1.57 (Ø40)
2.75 (69.9)
(52.4)
2.06
DIA 0.98
1.03
(Ø25)
Port plate 61
View Z
Valve mounting for
0.37 (9.5) 8.98 (228) 3.23 (82) ccw rotation
1.03 (26.2)
40
0
Z
DIA
88
Flange
ISO 3019-1 S
1.40 (35.7)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.63 (16)
1/4-20UNC-2B3) 4)
0.63 (16)
0.20 (5)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Spline according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 52 must be observed.
Ports
Designation Port for Standard Size5) Max. press. State
[psi (bar)]6)
B Service line, SAE J518 1 in 5100 (350) O
fastening thread ASME B1.1 3/8-16 UNC-2B; 0.71 (17) deep
S Suction line, SAE J518 1 1/2 in 145 (10) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.87 (20) deep
L Case drain fluid ISO 119267) 7/8-14 UNF-2B; 0.63 (16) deep 30 (2) O8)
L1 Case drain fluid ISO 119267) 7/8-14 UNF-2B; 0.63 (16) deep 30 (2) X8)
X Pilot pressure ISO 119267) 7/16-20UNF-2B; 0.45 (11.5) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2287) G 1/4 in; 0.47 (12) deep 5100 (350) O
5) For the maximum tightening torques the general instructions on page 52 must be observed.
6) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute.
7) The spot face can be deeper than as specified in the standard.
8) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 27/52
View Z
Valve mounting for
to flange surface
Valve mounting for ccw rotation
ccw rotation 6.81 (173)
X X
Z
(Ø25+0.4)
0.12 (3)
+0.4)
0.12 (3)
(Ø25
2.50
DIA 0.98
1.00
0.98
DIA 1.00
8.21 (208.5) (63.5) 4.33 (110)
8.50 (216) 4.61 (117)
to flange surface
DR DR
Pressure control, port plate 61 Pressure control, port plate 62
View Z
X
Z
9.65 (245)
5.75 (146)
to flange surface
DRG DRG
Pressure control, remotely operated, port plate 61 Pressure control, remotely operated, port plate 62
View Z
to flange surface Valve mounting for
9.65 (245) ccw rotation to flange surface Valve mounting for
8.98 (228) ccw rotation
3.23 (82) 6.06 (154)
max. 4.33 (110)
X
max. 4.33 (110)
1.57 (40)
1.57 (40)
X B
X
5.08 (129)
5.75 (146)
For details of connection options and drive shafts, see pages 25 and 26
28/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
4.41 (112)
4.41 (112)
X
3.58 (91)
X
1.57 (40)
max. 4.33 (110)
9.65 (245) 5.04 (128) 5.08 (129)
5.75 (146)
5.51 (140)
X
Z
2.50
5.73 (145.5)2)
(63.5)
ER7.: 10.98 in (279 mm) when using a sandwich plate pressure reducing valve
1)
ER7.: 7.11 in (180.5 mm) when using a sandwich plate pressure reducing valve.
2)
For details of connection options and drive shafts, see also pages 21 and 22
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 29/52
(Ø )
1 98
)
18
0.24 (6) 4.53 (115)
07 6 (
L
8
3.
Flange X
A
ISO 3019-1
1.57 (40)
4.09 (104)
45°
L 45°
X
DIA 5.0000
(Ø127-0.063 )
4.9975
0
3.62 (92)
4.09 (104)
0.71 (18) L1 7.13 (181)
2.09 (53)
8.27 (210)
8.54 (217)
4.23 (107.5) 5.63 (143)
10.12 (257)
6.30 (160)
W
1.03 (26.2)
Detail V Detail W
S
DIA 0.98 (Ø25) B
2.06 (52.4) 1.69 (42.9)
Port plate 91
Valve mounting for
3.62 (92) ccw rotation
0.50 (12.7) 10.31(262) 1.03 (26.2)
2.06 (52.4)
B
L X
X
(Ø127-0.063 )
4.9975
Z
0
S
(1.69 (42.9)
S
0.71 (18) L1 DIA 1.97 (Ø50)
2.09 (53) 3.06
8.78 (223) (77.8)
10.98 (279)
5/16-18UNC-2B3) 4)
1.50 (38)
5/16-18UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.75 (19)
0.75 (19) 0.63 (16)
0.20 (5)
0.20 (5) 0.20 (5)
W Splined shaft 1 in
15T 16/32DP1)2) (SAE J744)
1/4-20UNC-2B3) 4)
0.63 (16)
0.20 (5)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Spline according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 52 must be observed.
Ports
Designation Port for Standard Size5) Max. press. State
[psi (bar)]6)
B Service line, SAE J518 1 in 5100 (350) O
fastening thread ASME B1.1 3/8-16 UNC-2B; 0.71 (18) deep
S Suction line, SAE J518 2 in 145 (10) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.87 (22) deep
L Case drain fluid ISO 119267) 7/8-14 UNF-2B; 0.63 (16) deep 30 (2) O8)
L1 Case drain fluid ISO 119267) 7/8-14 UNF-2B; 0.63 (16) deep 30 (2) X8)
X Pilot pressure ISO 119267) 7/16-20 UNF-2B; 0.45 (11.5) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2287) G 1/4 in; 0.47 (12) deep 5100 (350) O
5) For the maximum tightening torques the general instructions on page 52 must be observed.
6) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute.
7) The spot face can be deeper than as specified in the standard.
8) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 31/52
View Z
Valve mounting for
Valve mounting for
to flange surface ccw rotation
ccw rotation
0.98(Ø25 )
+0.4
7.91 (201)
L
X
DIA1.00
L
X
Z
0.12 (3)
(Ø25+0.4)
0.12 (3)
DIA 0.98
1.00
2.89
9.55 (242.5) (73.5) 4.86 (123.5)
9.84 (250) 5.02 (127.5)
to flange surface
DR DR
Pressure control, port plate 91 Pressure control, port plate 92
View Z
Valve mounting for
ccw rotation Valve mounting for
ccw rotation
max. 4.33 (110)
X
Z
DRG DRG
Pressure control, remotely operated, port plate 91 Pressure control, remotely operated, port plate 92
View Z
X B
X
L
L
X
1.57 (40)
5.63 (143)
6.30 (160)
4.88 (124)
4.88 (124)
4.06 (103)
L L X
X
1.57 (40)
max. 4.33 (110)
10.98 (279) 5.43 (138) 5.63 (143)
6.28 (159.5)
5.55 (141)
L L
X
Z
2.89
6.30 (160)2)
(73.5)
ER7.: 12.36 in (314 mm) when using a sandwich plate pressure reducing valve.
1)
ER7.: 7.68 in (195 mm) when using a sandwich plate pressure reducing valve.
2)
For details of connection options and drive shafts, see also pages 21 and 22
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 33/52
Port plate 62
0.50 (12.7) 9.84 (250) Valve mounting for
V ccw rotation
0.24 (6) 6.89 (175)
)
X
06
(1
Flange
7
4.1
X
)
0.69 (17.5)
DIA 5.0000
4.9975
(Ø127-0.063
5.98 (152)
0
1.57 (40)
0.79 (20)
L1 7.13 (181)
3.74 (95) 8.27 (210)
10.83 (275) 4.65 (118) 5.84 (148.4)
12.48 (317)
6.50 (165)
Detail V Detail W
3.50 (88.9)
(66.7)
2.63
S
1.25 (31.8) 2.00
(50.8)
Port plate 61
3.90 (99)
1.25 (31.8)
0.50 (12.7) 6.89 (175) 2.63 (66.7)
L DIA 1.26 (Ø32)B
0.24 (6)
Flange
X
ISO 3019-1
max. 110
X
)
(55) (55)
2.16 2.16
DIA 5.0000
4.9975
(Ø127-0.063
40
Z
0
2.00 (50.8)
S
0.79 (20) DIA 2.36
L1
3.74 (95) (Ø60)
11.34 (288)
3.50 Valve mounting for
12.87 (327)
(88.9) ccw rotation
13.54 (344)
1.87 (47.5)
5/16-18UNC-2B3) 4)
7/16-14UNC-2B3) 4)
2.13 (54)
5/16-18UNC-2B3) 4)
0.75 (19)
1.10 (28) 0.75 (19)
0.20 (5) 0.20 (5)
0.20 (5)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Spline according to ANSI B92.1a, run out of spline is a deviation from standard.
3) Thread according to ASME B1.1
4) For the maximum tightening torques the general instructions on page 52 must be observed.
Ports
Designation Port for Standard Size5) Max. press. State
[psi (bar)]6)
B Service line, SAE J518 1 1/4 in 5100 (350) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.75 (19) deep
S Suction line, SAE J518 2 1/2 in 145 (10) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.87 (22) deep
L Case drain fluid ISO 119267) 1 1/16-12 UNF-2B; 0.71 (18) deep 30 (2) O8)
L1 Case drain fluid ISO 119267) 1 1/16-12 UNF-2B; 0.71 (18) deep 30 (2) X8)
X Pilot pressure ISO 119267) 7/16-20 UNF-2B; 0.45 (11.5) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2287) G 1/4 in; 0.47 (12) deep 5100 (350) O
5) For the maximum tightening torques the general instructions on page 52 must be observed.
6) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute.
7) The spot face can be deeper than as specified in the standard.
8) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 35/52
View Z
Valve mounting for
Valve mounting for to flange surface ccw rotation
ccw rotation 10.55 (268)
X X
0.12 (3)
DIA1.00
5.06 (128.5)
0.98
3.19 (81)
12.13 (308)
5.22 (132.5)
12.40 (315)
to flange surface
DR DR
Pressure control, port plate 61 Pressure control, port plate 62
View Z
X
Z
max. 4.33 (110)
DRG DRG
Pressure control, remotely operated, port plate 61 Pressure control, remotely operated, port plate 62
View Z
Z
1.57 (40)
max. 4.33 (110)
1.57 (40)
max. 4.33 (110)
5.83 (148)
6.50 (165)
Details on connection options and shaft ends can be found on pages 33 and 34
36/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
5.08 (129)
5.08 (129)
X
1.57 (40)
4.27 (108.5)
max. 4.33 (110)
ED7./ER7. ED7./ER7.
Electro-hydraulic pressure control, port plate 61 Electro-hydraulic pressure control, port plate 62
View Z
Valve mounting for to flange surface Valve mounting for
ccw rotation 10.55 (268) ccw rotation
4.60 (117) 1.40 (35.6)
5.51 (140)
5.51 (140)
X
X
ER7.: 14.92 in (379 mm) when using a sandwich plate pressure reducing valve.
1)
ER7.: 7.87 in (200 mm) when using a sandwich plate pressure reducing valve.
2)
Details on connection options and shaft ends can be found on pages 33 and 34
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 37/52
1.02 (26)
3019-1 45°
6.36 (161.6)
5.9975
7.87 (200)
5)
8.
0
(11
66
4.25 (108)
4.
0.83 (21) L1 6.36 (161.6)
3.07 (78) 7.87 (200)
10.83 (275) 5.16 (131) 7.20 (183)
12.48 (317) 8.23 (209)
Detail V Detail W
3.50 (88.9)
DIA 2.48 (Ø63)
(66.7)
(Ø32) 2.63
B S
DIA 1.26
1.25 2.00
(31.8) (50.8)
Port plate 61
5.51 (140)
0.50 (12.7) 2.63 (66.7)
0.25 (6.4) 6.81 (173) DIA 1.26 (Ø32)
(31.8)
Flange B
1.25
4.92 (125)
3019-1 L X
(Ø152.4 -0.063)
DIA 6.0000
2.36 2.36
5.9975
(60) (60)
0
B
Z
S
1.02 (26)
(50.8)
2.00
Port plate 62
0.50 (12.7) 9.78 (248.5) Valve mounting for
0.24 (6) 7.83 (199) V ccw rotation
L X B
Flange
1.02 (26)
4.41 (112) 4.96 (126)
3019-1
0.69 (17.5)
)
DIA 5.0000
4.9975
8.
(Ø127 -0.063
5.98 (152)
(11
0
67
4.
4.25 (108)
0.79 (20) 7.12 (181)
L1
4.09 (104) S 8.27 (210)
11.85 (301) 5.16 (131) 7.20 (183)
13.50 (343) 8.23 (209)
W
DIA 2.48
Detail V Detail W
(Ø63)
3.50 (88.9)
66.7
B
DIA 1.26
(Ø32)
Port plate 61
5.51 (140)
0.50 (12.7) 14.92 (379) 2.62 (66.7)
1.25 (31.8)
2.36 2.36
DIA 5.0000
(60) (60)
4.9975
(Ø127 -0.063
B
0
Z
X S
1.02 (26)
2.00 (50.8)
S
0.79 (20)
L1 DIA 2.48 (Ø63)
4.09 (104) 3.50 (88.9)
12.56 (319)
15.94 (405)
Valve mounting for
ccw rotation
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 39/52
2.64 (67)
1/2-13UNC-2B2) 3)
1.26 (32)
0.20 (5)
2.09 (53)
2.95 (75)
1) ANSI B92.1a, 30° pressure angle, flat root, side fit, tolerance class 5
2) Thread according to ASME B1.1
3) For the maximum tightening torques the general instructions on page 52 must be observed.
Ports
Designation Port for Standard Size4) Max. press. State
[psi (bar)]5)
B Service line, SAE J518 1 1/4 in 5100 (350) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.94 (24) deep
S Suction line, SAE J518 2 1/2 in 145 (10) O
fastening thread ASME B1.1 1/2-13 UNC-2B; 0.94 (24) deep
L Case drain fluid ISO 119266) 1 1/16-12 UNF-2B; 0.71 (18) deep 30 (2) O7)
L1 Case drain fluid ISO 119266) 1 1/16-12 UNF-2B; 0.71 (18) deep 30 (2) X7)
X Pilot pressure ISO 119266) 9/16-18UNF-2B; 0.51 (13) deep 5100 (350) O
X Pilot pressure with DG-control DIN ISO 2286) M14 x 1.5; 12 deep 5100 (350) O
MH Gauge port, high pressure DIN 3852 M14 x 1.5, 12 deep 5100 (350) X
4) For the maximum tightening torques the general instructions on page 52 must be observed.
5) Depending on the application, short-term pressure spikes can occur. Consider this when selecting measuring equipment and
fittings. Pressure values in psi (bar) absolute.
6) The spot face can be deeper than as specified in the standard.
7) Depending on the installation position, L or L1 must be connected (see also installation instructions on pages 48, 49)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
40/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
View Z
Valve mounting for
Valve mounting for to flange surface ccw rotation
ccw rotation 10.55 (268)
0.10 (2.6)
0.10 (2.6)
B
L X L X
Z
1.10 (28)
1.10 (28)
S
DR DR
Pressure control, port plate 61 Pressure control, port plate 62
View Z
1.02 (26)
4.96 (126)
4.96 (126)
B
L L
DRG DRG
Pressure control, remotely operated, port plate 61 Pressure control, remotely operated, port plate 62
View Z
4.96 (126)
X B
2.20 (56)
L L
5.51 (140)
2.20 (56)
4.96 (126)
14.92 (379) 6.42 (163) 7.20 (183)
8.23 (209)
5.07 (128.9)
L
X
X
Z
ER7.: 15.12 in (384 mm) when using a sandwich plate pressure reducing valve.
1)
ER7.: 8.43 in (214 mm) when using a sandwich plate pressure reducing valve.
2)
Details on connection options can be found on pages 37, 38 and 39
42/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
Cut A - B NG A1 A2 A3 A42)
A3 18 7.16 0.39 1.70 M10 x 1.5,
A 45° A2 (182) (10) (43.3) 0.57 (14.5) deep
28 8.03 0.39 1.33 M10 x 1.5,
(204) (10) (33.7) 0.63 (16) deep
45 9.02 0.42 2.10 M10 x 1.5,
9
–0.020)
4.1 )
(Ø82.55+0.050
(229) (10.7) (53.4) 0.63 (16) deep
3.2508
DIA 3.2520
DIA 06.5
1 71 10.51 0.46 2.41 M10 x 1.5,
(Ø
(267) (11.8) (61.3) 0.79 (20) deep
100 13.31 0.41 2.56 M10 x 1.5,
(338) (10.5) (65) 0.63 (16) deep
A4
1401) 13.78 0.43 3.04 M10 x 1.5,
0.39 (350) (10.8) (77.3) 0.63 (16) deep
B
to mounting flange A1 (10)
1) D-flange only
Cut A - B NG A1 A2 A3 A42)
A3 18 7.16 0.74 1.52 M10 x 1.5,
A 45° 0.39 (182) (18.8) (38.7) 0.57 (14.5) deep
(10)
28 8.03 0.74 1.52 M10 x 1.5,
(204) (18.8) (38.7) 0.63 (16) deep
45 9.02 0.744 1.52 M10 x 1.5,
9
–0.02 )
DIA 06.5
1 71 10.51 0.84 1.63 M10 x 1.5,
(Ø
(267) (21.3) (41.4) 0.79 (20) deep
100 13.31 0.75 1.53 M10 x 1.5,
(338) (19) (38.9) 0.63 (16) deep
A4
1401) 13.78 0.744 1.52 M10 x 1.5,
A2 (350) (18.9) (38.6) 0.63 (16) deep
B
to mounting flange A1 1) D-flange only
Cut A - B NG A1 A2 A3 A42)
A A3 45 9.02 0.724 1.84 M12 x 1.75,
45° 0.39 (229) (18.4) (46.7) 0.71 (18) deep
(10)
71 10.51 0.82 1.93 M12 x 1.75,
(267) (20.8) (49.1) 0.79 (20) deep
100 13.31 0.716 1.83 M12 x 1.75,
–0.02 )
5.75 )
(Ø101.6 +0.05
(338) (18.2) (46.6) 0.79 (20) deep
DIA 4.0008
4.0020
46
(Ø1 1401) 13.78 0.72 1.81 M12 x 1.75,
(350) (18.3) (45.9) 0.79 (20) deep
1) D-flange only
A4
A2
B to mounting flange A1
Cut A - B NG A1 A2 A3 A42)
A3 71 10.51 0.86 2.31 M16 x 2,
45° 0.51 (267) (21.8) (58.6) continuous
omitted A omitted
(13)
for NG71 for NG71 100 13.31 0.77 2.22 M16 x 2,
(338) (19.5) (56.4) continuous
1401) 13.78 0.76 2.21 M16 x 2,
–0.02 )
7.12
5.0008
DIA 5.0020
DIA 1)
8
(Ø1 1) D-flange only
A4
B A2
to mounting flange A1
7.12
–0.02
Ø127 +0.05
A4
B
A3a
A2
to mounting flange A1
–0.02 )
6.36 (161.6)
(Ø152.4 +0.07
DIA 6.0008
6.0027
B A2
A4 to mounting flange A1
6.36 (161.6)
Combination pumps A10VO + A10VO Before finalizing your design request a certified
installation drawing.
Dimensions in inches and (mm).
When using combination pumps it is possible to have multiple, mutually independent circuits without the need for a splitter
gearbox.
When ordering combination pumps the model codes for the first and the second pump must be joined by a "+".
Order example:
A10VSO100DFR1/31R-VSB12K04+
A10VSO45DFR/31R-VSA12N00
If no further pumps are to be factory-mounted, the simple type code is sufficient.
It is permissible to use a combination of two single pumps of the same size (tandem pump), considering a dynamic mass accele-
ration force of maximum 10 g (= 98.1 m/s2) without an additional support bracket.
Each through drive is plugged with a non-pressure-resistant cover. Before commissioning the units, they must therefore be
equipped with a pressure-resistant cover.
Through drives can also be ordered with pressure-resistant covers. Please specify in clear text.
For combination pumps comprising more than two pumps, the mounting flange must be calculated for the permissible moment of
inertia.
NG 18 28 45 71 100 140
Permissible moment of inertia
static Tm lb-ft 369 649 1010 1593 2213 33191)
(Nm) (500) (880) (1370) (2160) (3000) (4500)1)
lb-ft 22132)
(Nm) (3000)2)
dynamic at 10 g (98.1 m/s2) Tm lb-ft 37 65 101 159 221 332 1)
(Nm) (50) (88) (137) (216) (300) (450)1)
lb-ft 1322)
(Nm) (300)2)
Mass with through-drive plate m lbs 30.8 41.9 55.1 86 119 150
Mass without through drive (kg) (14) (19) (25) (39) (54) (68)
(e.g. 2nd pump)
m lbs 26.5 33 46 73 99 132
(kg) (12) (15) (21) (33) (45) (60)
Distance center of gravity l in 3.54 4.33 5.12 5.91 6.30 6.30
(mm) (90) (110) (130) (150) (160) (160)
1) 4-hole flange (D)
2) 2-hole flange (C)
Circuit symbol 2. Turn the solenoid body (2) to the desired position.
Without bidirectional suppressor diode 3. Retighten the mounting nut of the solenoid. Tightening
torque: 4 +0.7 lb-ft (5+1 Nm) (size WAF 26, 12-pt
DIN 3124).
On delivery, the position of the connector may differ from that
shown in the brochure or drawing.
Mating connector
DEUTSCH DT06-2S-EP04
Bosch Rexroth Mat. No. R902601804
Consisting of: DT designation
–– 1 case _ _______________________________DT06-2S-EP04
–– 1 wedge ________________________________________W2S
–– 2 sockets _____________________________ 0462-201-16141
The mating connector is not included in the delivery contents.
This can be supplied by Bosch Rexroth on request.
1.44 (36.7)
(2)
1.44 (36.7)
(1)
DIA 1.46
(Ø37)
1.97 (50)
2.70 (68.5)
48/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
Installation instructions
General Below-reservoir installation (standard)
The axial piston unit must be filled with hydraulic fluid and air Below-reservoir installation means the axial piston unit is ins-
bled during commissioning and operation. This must also be talled outside of the reservoir below the minimum fluid level.
observed following a longer standstill as the axial piston unit
empty via the hydraulic lines.
Particularly with the "drive shaft up/down" installation position, 1 2
filling and air bleeding must be carried out completely as there
a min a min
is, for example, a danger of dry running.
SB SB
The case drain fluid in the motor housing must be directed to ht min ht min
the reservoir via the highest case drain port (L1, L2, L3). h min h min
For combinations of multiple units, make sure that the respec- L
tive case pressure in each unit is not exceeded. In the event of
pressure differences at the case drain ports of the units, the L L1
shared case drain line must be changed so that the minimum S S
permissible case pressure of all connected units is not excee- L1
ded in any situation. If this is not possible, separate case drain
lines must be laid if necessary.
To achieve favorable noise values, decouple all connecting
lines using elastic elements and avoid above-reservoir installa- 3 4
tion.
a min a min
In all operating conditions, the suction line and case drain line
must flow into the reservoir below the minimum fluid level . SB SB
The permissible suction height hS is a result of the overall ht min ht min
h min h min
pressure loss, but may not be greater than hS max = 31.50 in
(800 mm). The minimum suction pressure at port S must also
not fall below 12 psi (0.8 bar) absolute during operation. L1 S S
Installation position
L
See the following examples 1 to 12. L1
Additional installation positions are available upon request. L
Installation instructions
Above-reservoir installation Inside-reservoir installation
Above-reservoir installation means the axial piston unit is Inside-reservoir installation is when the axial piston unit is
installed above the minimum fluid level of the reservoir. installed in the reservoir below the minimum fluid level.
To prevent the axial piston unit from draining, a height The axial piston unit is completely below the hydraulic fluid.
difference hES min of at least 0.98 in (25 mm) at port L 1 is
If the minimum fluid level is equal to or below the upper edge
required in installation position 6.
of the pump, see chapter "Above-reservoir installation".
Observe the maximum permissible suction height
Axial piston units with electrical components (e.g. electric cont-
hS max = 31.50 in (800 mm).
rol, sensors) may not be installed in a reservoir below
A check valve in the case drain line is only permissible in the fluid level.
individual cases. Consult us for approval.
9 10
5 6 a min a min
F F
hES min
L L
L L1 SB ht min SB ht min
L1
S L
S S
L1 L1
h min S h min
hs max hs max
SB SB
ht min
11 12
ht min
h min h min
a min a min
a min a min
7 8 L1 S
S
F F SB ht min SB ht min
L1 S S L1
L L
h min h min
L
L1
L
hs max
hs max Installation position Air bleed Filling
SB SB 9 L L, L1
ht min ht min
h min h min 10 L1 L, L1
a min a min 11 L1 S + L, L1
12 L S + L, L1
Notes
RA-A 92701/03.12 (A) A10V(S)O Series 31 Bosch Rexroth Corp. 51/52
Notes
52/52 Bosch Rexroth Corp. (A)A10V(S)O Series 31 RA-A 92701/03.12
General instructions
–– The A10VO / A10VSO pump is designed to be used in open circuit.
–– Project planning, installation and commissioning of the axial piston unit require the involvement of qualified personnel.
–– Before operating the axial piston unit, please read the appropriate instruction manual thoroughly and completely. If necessary, request these
from Bosch Rexroth.
–– During and shortly after operation, there is a risk of burns on the axial piston unit and especially on the solenoids.
Take appropriate safety measures (e.g. by wearing protective clothing).
–– Depending on the operating conditions of the axial piston unit (operating pressure, fluid temperature), the characteristics may shift.
–– Service line ports:
-- The ports and fastening threads are designed for the specified maximum pressure. The machine or system manufacturer must ensure that
the connecting elements and lines correspond to the specified application conditions (pressure, flow, hydraulic fluid, temperature) with the
necessary safety factors.
-- The service line ports and function ports are only designed to accommodate hydraulic lines.
–– Pressure cut-off and pressure control do not provide security against pressure overload. A separate pressure relief valve is to
be provided in the hydraulic system.
–– The data and notes contained herein must be adhered to.
–– The product is not approved as a component for the safety concept of a general machine according to ISO 13849.
–– The following tightening torques apply:
-- Fittings:
Observe the manufacturer‘s instruction regarding the tightening torques of the used fittings.
-- Mounting bolts:
For mounting bolts with metric ISO thread according to DIN 13 or thread according to ASME B1.1, we recommend checking the tightening
torque individually according to VDI 2230.
-- Female threads in axial piston unit:
The maximum permissible tightening torques MG max are maximum values for the female threads and must not be exceeded. For values, see the
following table.
-- Threaded plugs:
For the metal threaded plugs supplied with the axial piston unit, the required tightening torques of the threaded plugs
MV apply. For values, see the following table.
Ports Maximum permissible Required Size of
tightening torque for tightening torque for hexagon socket of
female threads MG max threaded plugs MV threaded plugs
Standard Thread size
ISO 11926 7/16-20 UNF-2B 40 Nm 18 Nm 3/16 in
3/4-16 UNF-2B 160 Nm 70 Nm 5/16 in
9/16-18 UNF-2B 80 Nm 35 Nm 1/4 in
7/8-14 UNF-2B 240 Nm 110 Nm 3/8 in
1 1/16-12 UNF-2B 360 Nm 170 Nm 9/16 in
DIN 3852 M14 x 1.5 80 Nm 45 Nm1) 6 mm
DIN ISO 228 G 1/4 in 70 Nm – –
1) The tightening torques of the threaded plugs MV apply for screws in the "dry" state as received on delivery and in the
"lightly oiled" state for installation