Installation in 3 steps... T1 T2
Permanent Live
1 W
ire the
2 P
ower Up
3 C onfigure not required
Receiver Box
NL
5(3)A
L B
N
1.2-1.5m
B
B NL
L L B
N N
B) P
ower Up the Heating System and Receiver Box
and do a quick functional test of the receiver box to check that it switches the
boiler.
C) R
eplace the cover he thermostat and receiver
T
box in this pack are pre-bound.
Locate the hinges at
the top of the cover
and wall plate, close Press the button once to check the
the cover and secure After power up boiler switches on - The button LED
with the screw. the LED should be solid YELLOW.
should be Press again once to switch the boiler
solid GREEN off - The button LED should go OFF.
3 Configure the System
Parameter
Parameters
No Description Settings (default in bold)
Specific settings for the thermostat Number
and heating system can be 1:LA Language 1 = EN, 2 = NL, 3 = FR, 4 = DE, 5 = ES, 6 = IT
configured in the advanced menu. Parameter
Heating Cycle Rate (cph) 3 (oil boiler / thermal actuator)
Setting 2:CR
6 (gas or combi boiler / zone valve)
Press and hold and then 9
buttons together until the display 12
changes (approx. 3sec). 3:OT Minimum on time 1 - 5 (mins) (set to 4 mins for oil boiler)
4:LL Lower Temperature Limit 5 - 21 (°C)
OpenTherm® Compatibility
OpenTherm® compatibility is offered only by the Receiver Box. The Thermostat will
control heat demand as normal but will not show OpenTherm® specific boiler data
on the display - Refer to the boiler instructions for how to view the boiler data.
14:A RF Binding Mode 0, 1 = Enter bind mode Display = Faulty temperature sensor Replace thermostat or check wiring to
remote temperature sensor if fitted
14:B RF Signal Strength Test 0, 1 = Perform Signal Test
Thermostat shows heat Boiler (water) already Normal behaviour - wait for
14:C Delete RF Binding Data 0, 1 = Delete Bind Data demand but boiler at temperature water temperature to drop
doesn't respond
Faulty wiring connection Check wiring at thermostat and boiler terminals
A) Clear the binding data from the Receiver Box:
Press & hold the reset ‘pinhole’ button for 3sec. Thermostat display shows Wireless communication Move thermostat to a location where
Press
and Receiver Box with Receiver Box is lost wireless communication is reliable
B) Put the Receiver Box into bind mode: for 3sec
to clear LED is flashing RED
Hold button for 3sec - button lights ORANGE for binding Thermostat display shows Thermostat and Receiver Follow the Wireless Binding Instructions
3sec followed by LED flashing ORANGE. and Receiver Box not bound
C) P
ut the Thermostat into bind mode: Box LED is OFF
Change parameter No 14 A (RF Binding Mode) to ‘1’ and press Receiver Box LED Receiver Box is in Wait for bind mode to time out
is flashing ORANGE bind mode (3min) or bind a Thermostat
If successful the Receiver Box LED willl turn solid
GREEN and the Thermostat will show