Вы находитесь на странице: 1из 464

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Conditioning | Air Curtains and Heating

Products | Tunnel Fans

Systemair Fans
Product catalogue
2 | Systemair

Reveal the Secret of Fresh Air!

© Systemair 2013. Systemair reserves the right to make Since 1974, Systemair has been taking care of a vital
technical changes. For updated documentation, please refer resource. Today, the company is one of the global leaders
to www.systemair.com.
in the field of ventilation technology. A success story
which started in Skinnskatteberg, Sweden which has
revolutionised the world of ventilation with the invention
of the in-line centrifugal fan.
Systemair | 3

Contents
Systemair Across the World 4 EC-Fans 16
Fans – Overview 6 EC-Vent 18
Overview Applications 8 Other Products from Systemair 22
Innovations 10 A Good Indoor Climate is Vital 24
ErP - Guidelines 12 Selection Tools 25
Motor Efficiency Classification IE2 14

Technical data
Circular Duct Fans 26 Centrifugal Fans 332

Rectangular and Square Duct Fans 86 Domestic Fans 348

Roof Fans 158 Electrical Accessories 354

Axial Fans 200 Accessories 386

Explosion Proof Fans 230 Wiring 442

Smoke Extract Fans 264

Fans for Aggressive Media 320

Since then, the company has continued to grow, and familiar with the conditions and have the necessary
today it offers a complete range of standard-setting know-how. More than 4000 employees in more than
ventilation technologies. Whether it is the ventilation 60 subsidiaries in over 45 countries ensure the neces-
concept for a shopping mall, the controlled residential sary proximity to the customer. We invite you to join
ventilation of a single-family home or the ventilation us in discovering the world of ventilation technology
of tunnels and metro stations – Systemair experts are in this catalogue.
4 | Systemair

Systemair Across the World

Skinnskatteberg, Sweden Windischbuch, Germany Maribor, Slovenia


The Group headquarters, distribution center Production facility and distribution center, Specialist production of high temperature fans.
and largest production site. Production of specialising in engineered products.
compact air handling units and a wide range Hasselager, Denmark
of fans and accessories. Production of air
Langenfeld, Germany Production of air handling units.
curtains and fan heaters for Frico, a company
within the Systemair Group. Manufacturing of air curtains and heating
products. Bratislava, Slovakia
Hässleholm, Sweden Production of air distribution products and fire/
Production of heating and cooling coils. Mühlheim an der Ruhr, Germany smoke dampers.
Production of air handling units.
New Dehli, India
Ukmerge, Lithuania Production of air handling equipment for the
Production of air handling units. Asian market.
Systemair | 5

Quality: Save Energy, lower running cost!


Systemair is certified in accordance with ISO Our label “Green Ventilation” features products
9001; ISO 14001, ATEX and European fire with a high energy saving potential. All products
safety standard EN 12101-3. Our research and labelled with “Green Ventilation” combine energy
development laboratories are one of the most economy with energy efficiency.
modern in Europe; measurements are made in
accordance with international standards such
as AMCA and ISO.

Skinnskatteberg, Sweden
Dal, Eidsvoll, Norway Hässleholm, Sweden
Hasselager, Denmark Ukmerge, Lithuania
Mühlheim a.d.R., Germany
Waalwijk, The Netherlands Langenfeld, Germany
Bouctouche, Canada Windischbuch, Germany Bratislava, Slovakia
Tillsonburg, Canada Milano, Italy Maribor, Slovenia

Madrid, Spain Istanbul, Turkey


Lenexa, USA

New Delhi, India

Kuala Lumpur, Malaysia

Kuala Lumpur, Malaysia Madrid, Spain Dal, Eidsvoll, Norway


Production of ventilation equipment for the Production of air handling units. Production of air handling units for the
Asian market. Norwegian market.
Bouctouche, Canada
Lenexa, USA Production for energy and heat recovery Istanbul, Turkey
Manufacturing and distribution center for ventilation for residential applications for Production of air handling units.
residential and commercial ventilation products the American market.
for the North and South American market. Waalwijk, The Netherlands
Tillsonburg, Canada Production of air handling units.
Milano, Italy In Tillsonburg we develop, engineer, service
Production of a wide range of both water and and manufacture school classroom ventilation
air cooled chillers and heat pumps for comfort equipment for the American market.
cooling.
6 | Fans - Overview

Fans – Overview
Systemair has a wide range of fans for use in various applications from small office premises to larger industrial
applications. Common to all items in the range is that components have been developed to satisfy stringent
demands for low energy consumption. The fans have all undergone extensive testing, both in the laboratory and
out in the field, in order to comply with current and future demands for low energy consumption. All products are
also manufactured to comply with environmental requirements.

Circular duct fans up to 2.7 m3/s Page: 26-85

For systems with higher pressure losses we offer the K and


RVK fans. The KV range can be installed directly on the wall.
For higher air volumes we offer the KD range with mixed flow
impellers. The new prioAir provides the lowest specific fan
power on the market, and various box fan ranges offer a low
sound level.

Rectangular and square duct fans up to 7.4 m3/s Page: 86-157

Systemair rectangular and square duct fans have been devel-


oped for use in compact exhaust and supply air systems. This
range is available in a wide performance spectrum.

Roof fans up to 15.2 m3/s Page: 158-199

Systemair roof fans have been developed for use in effective


exhaust air systems. Roof fans with circular or square con-
nection and available for vertical discharge and for horizontal
discharge.

Axial fans up to 70 m3/s Page: 200-229

Systemair axial fans have been developed for installation in


effective supply and exhaust air systems. Axial fans for use in
low and for medium/high pressure systems.

Explosion proof fans up to 12.4 m3/s Page: 230-263

Systemair explosion proof fans have been developed to be


used in effective supply and exhaust air systems allocated
to category 2 (zone 1) and category 3 (zone 2) in explosion
hazardous areas.
Fans - Overview | 7

Smoke extract fans up to 70 m3/s Page: 264-319

600°C 120min 400°C 120min 300°C 120min

Systemair offers different types of smoke and heat extract


fans: Centrifugal roof and box fans, centrifugal wall/duct
fans and axial fans. All fans are approved for dual purpose
ventilation, i.e. for normal daily ventilation and for emergency
ventilation in case of a fire.

Jet fans Page: 306-317

300°C 120min

Systemair jet fans for Car Park Ventilation, axial or centrifugal


solutions, certified in accordance with EN 12101-3. Complete
solutions including control systems and CFD.

Fans for aggressive media up to 2.11 m3/s Page: 320-331

These sturdy plastic fans have been developed especially for


applications where dirty or aggressive gases can contami-
nate the exhaust air. Typical applications are laboratories in
medical or pharmaceutical institutions and in the food and
chemical industry.

Centrifugal fans up to 3 m3/s Page: 332-347

Centrifugal fans for various applications e.g. extraction from


kitchens, process air systems, industrial ovens. Fans are
equipped with impellers with forward and backward curved
blades. Also available with EC motors and motors outside the
airstream.

Domestic fans up to 0.19 m3/s Page: 348-353

Domestic fans for the ventilation of bathrooms, toilets, stor-


age rooms, for installation on walls, in ceilings, in ducts and in
windows.
8 | Overview Applications

Overview Applications

Product characteristics

100°C 120°C 200°C 300°C 120min 400°C 120min 600°C 120min

Page Continuous oper. Continuous oper. Continuous oper. EN 12101-3 EN 12101-3 EN 12101-3
up to 100°C up to 120°C up to 200°C 300°C/120 min. 400°C/120 min. 600°C/120 min.

Circular duct fans 26-85


Rect./square duct fans 86-157 X
Roof fans 158-199 X X
Axial fans 200-229 X X X X X
Explosion proof fans 230-263
Smoke extract fans 264-319 X X X X X
Fans for aggressive media 320-331
Centrifugal fans 332-347 X X X
Domestic fans 348-353

Page Greenhouses Agriculture Wine cellars / Offices Restaurants Kitchens /


basements and bars bakeries

Circular duct fans 26-85 X X X X


Rect./square duct fans 86-157 X X X X X
Roof fans 158-199 X X X X X
Axial fans 200-229 X X
Explosion proof fans 230-263 X
Smoke extract fans 264-319 X X
Fans for aggressive media 320-331 X X X
Centrifugal fans 332-347 X X X
Domestic fans 348-353 X X
Overview Applications | 9

Areas of application

Explosion Car Park Warehouses Multi storage Garages Workshops Supermarket Laboratories
protection buildings

X X X X X X
X X X X X X
X X X X X X
X X X X X X
X X X X X
X X X X X X
X X X
X X X X X X
X X X

Areas of application

Offshore Paint shops Cinemas and Smoker lounges Sports centers Industry Inflatable Motor
theatres structures cooling

X X X X X
X X X X X X
X X X X X
X X X X
X X
X X X X
X X
X X X X X X
X X X X
10 | Innovations

Innovations

KD EC
Circular duct fans
KVO EC
Circular duct fans
prioAir
Circular duct fans

RS EC
DHS sileo RSI EC
AW sileo DVS sileo Rectangular duct fans
AR sileo DVSI sileo
Axial fans Roof fans

prioAir circular duct fan Fans of the sileo generation The roof fans DHS/DVS and DVSI sileo
More performance. Less energy A new generation of modern Systemair convince with a quiet-running high-
consumption. fans, consequently developed towards performance impeller in combination
With its revolutionary, fluidic optimized one goal: low noise level - strong with a fluidically more advanced inlet
impeller it can move almost double the performance. nozzle. In many cases this means that
air volumes of comparable inline-fans You can see and hear the result: a additional silencer no longer need to be
reduction in sound of almost 50% at used.
with a lower use of energy.
the same system performance and an DHS / DVS und DVSI sileo ............ p. 176
prioAir ............................................. p. 28
increased level of efficiency compared to
its predecessors.

The secret of the new AW and AR sileo


low pressure axial fans is the noise and
performance optimized impeller blades.
AW and AR sileo ........................... p. 208
Innovations | 11

E W !
N
EC-Vent
The intelligent FRQ
control system Frequency
converter
DVG EC
Smoke extract
roof fans

KVB/F
Smoke extract
box fans

AW sileo EC
Axial fans
MUB/T EC
Multibox for 120°C

Well prepared for the future with EC- MUB/T EC ...................................... p. 148 The intelligent control unit
fans from Systemair DVG EC ........................................... p. 280 Our new intelligent control unit promotes
The requirements on intelligent and new levels of comfort and energy
energy efficient ventilation technology efficiency by adapting fan speed to
The energy efficient axial fans of sileo
will continue to grow in the future. ventilation demand via remote-sensor
generation.
Therefore Systemair focuses more on input.
ventilation products equipped with AW sileo EC .................................... p. 202 EC-Vent ......................................... p. 365
modern EC technology and extends the
range of EC fans continuously. Belt driven smoke extract fan Wide range of accessories
KVB/F is our new inline box fan for Our wide range of accessories includes a
RS & RSI EC ..................................... p. 98 400°/2h. Belt driven and for air flows up lot of new products such as the fre-
KVO EC ............................................ p. 48 to 48000 m³/h. quency inverter FRQ for energy efficient
KVB/F ............................................ p. 292 speed control.
KD EC ............................................... p. 56
FRQ ................................................ p. 361
12 | ErP Guidelines

For more information please use our ErP


ErP - Guidelines guideline leaflet on www.systemair.com

Systemair fans and Eco-design directive


Globally increasing electricity consumption automatically in- The European Union saw the adoption of European Parliament
creases the production of CO2 released into the atmosphere. directives 2005/32/EC and 2009/125/EC, which relates in the
The excess content of CO2 in the air has a negatively impact first case only to electrical motors themselves manufactured
on our planet's climate. The Kyoto Protocol was and still is de- according to the IEC standard, and in the second case, to fans
signed to curb this. It is an agreement adopted and signed by as machines driven by electrical motors. The directives require
the European Union in 1997. The main aim of the protocol is manufacturers to increase the efficiency of these machines ac-
to decrease CO2 emissions by 20 % by the year 2020. Since cording to a fixed timetable. As primarily a European producer
electric motors consume 30-40 % of the electricity produced of fans, Systemair has worked for several years on preparing for
worldwide, this is an obvious area with the greatest potential the conversion to this new European legislation. Thanks to this,
for achieving savings. it is now fully prepared.

Groups of rated input power of electric motors and their share in total worldwide consumption of electricity energy

Directive 2005/32/EC – increasing efficiency electric motors


Directive 2005/32/EC and arising from it Regulation (EC) No concerns electric motors regardless of their intended use.
640/2009 requires production of electric motors according to It is irrelevant whether the electric motor drives a fan, pump or
standard IEC 60034-30:2008 with internationally determined other machine.
efficiency IE measured according to IEC 60034-2-1:2007. The
timetable for converting to this new standard includes three The Standard IEC 60034-30 was adopted internationally and
phases, three scopes of rated input powers of electric mo- also means unification of production, designation and meas-
tors and a scale of minimum IE efficiency ranging from IE1 to urement of electric motor efficiency on a global scale. Until this
IE3. The ranges of the affected input powers are based on the time, individual local normalizers (NEMA, EPACT, CSA, CEMEP,
distribution of the total shares of nominal electric motor input COPANT, AS/NZS, JIS, GB and others) have employed varying
power to the world's electricity consumption. The directive only standards and procedures.

Timetable Rated input power Minimum efficiency


16. 6. 2011 0.75kW ÷ 375 kW IE2
0.75 kW ÷ 7,5 kW IE2
1. 1. 2015
7.5 kW ÷ 375 kW IE3 or IE2 + FM
1. 1. 2017 0.75 kW ÷ 375 kW IE3 or IE2 + FM

Timetable for conversion to IE efficiency according to Directive 2005/32/EC


ErP Guidelines | 13

The first phase concerns electric motors with an output range


of 0.75 kW to 375 kW. The main technical difference besides
higher efficiency IE2 is the option of controlling revolutions only
by means of a frequency converter and built-in thermistors as
sensors assessing overheating of motors. In the second stage,
i.e. from 01.01.2015, IE3 efficiency shall be required for mo-
tors within the output range of 7.5 kW to 375 kW, working only
at nominal rotational speed. For variable speed control, it shall
be possible to use IE2 motors in connection with a frequency
converter. Starting 01.01.2017, when the third phase begins,
the rule requiring efficiency IE3 or operation of motors IE2 with
frequency converters shall spread across the entire range of af-
fected rated outputs 0.75 kW to 375 kW. Image 2: Electric motor standard IEC 60034

Efficiency Minimum Efficiency Minimum


Motor class efficiency class efficiency
IEC CEMEP
IE3 89.2 % - -
5.5 kW, 2-pole IE2 87.0 % EFF1 88.6 %
IE1 84.7 % EFF2 85.7 %

Comparison of efficiency of EFF used in the EU until 16.6.2011 according to CEMEP with globally valid IE efficiency according to IEC.
The European standards committee CEMEP did not have minimum efficiency requirements, so the standard class was EFF2.

Directive 2009/125/EC (ErP 125) – increasing of efficiency of fans


(motor and impeller)
COMMISSION REGULATION (EU) No 327/2011 of 30 March cross flow fan) the directive requires a target minimum effi-
2011 implementing Directive 2009/125/EC of the European ciency expressed by the efficiency class N and by a formula for
Parliament and of the Council with regard to ecodesign require- calculation. The directive relates to fans in rated output range
ments for fans driven by motors with an electric input power of 125 W to 500 kW. Only impeller, motor and parts which are
between 125 W and 500 kW. For any type of fan (axial fan, necessary to guide the air in and out from the impeller is con-
centrifugal forward curved radial fan and centrifugal radial sidered. The timetable for conversion is also multistep, where
bladed fan, centrifugal backward curved fan without housing, only two terms are determined - 01.01.2013 and 01.01.2015.
centrifugal backward curved fan with housing, mixed flow fan,

Regulation of the European Commission (EU) No. 327/2011


Subject and area of activity
1. This regulation establishes ecodesign requirements for plac- c) designed specifically to operate:
ing on the market and putting into service of fans, including - where operating temperatures of the gas being moved
those integrated into other energy-related products as cov- exceed 100 °C
ered by Directive 2009/125/EC. - where operating ambient temperature for the motor, if
located outside the gas stream, driving the fan exceeds
2. The Regulation shall not apply to fans integrated in:
65 °C
a) products with a sole electric motor of 3 kW or less where
- where the annual average temperature of the gas being
the fan is fixed on the same shaft used for driving the
moved and/or the operating ambient temperature for
main functionality,
the motor, if located outside the gas stream, are lower
b) laundry and washer dryers ≤ 3 kW maximum electrical in- than – 40 °C,
put power ≤ 3 kW, - with a supply voltage > 1 000 V AC or > 1 500 V DC
c) k
 itchen hoods < 280 W total maximum electrical input - in toxic, highly corrosive or flammable environments or
power attributable to the fan(s) < 280 W. in environments with abrasive substance;
3. This Regulation shall not apply to fans, which are: d) p
 laced on the market before 1 January 2015 as replace-
a) designed specifically to operate in potentially explosive at- ment for identical fans integrated in products which were
mospheres as defined in Directive 94/9/EC of the Europe- placed on the market before 1 January 2013; except that
an Parliament and of the Council (1) the packaging, the product information and the techni-
cal documentation must clearly indicate regarding (a), (b)
b) designed for emergency use only, at short-time duty, with
and (c) that the fan shall only be used for the purpose for
regard to fire safety requirements set out in Council Direc-
which it is designed and regarding (d) the product(s) for
tive 89/106/EC (2)
which it is intended.
14 | Efficiency classification IE2

Motor Efficiency Classification IE2 IE2


With the aim to reduce world-wide energy consumption, the International Electrotechnical Commission 2009/640/EG

(IEC) has developed and published a new standard, IEC 60034-30:2008. This new worldwide standard
defines efficiency classes of low voltage three phase motors for 50/60Hz supply with motor powers
between 0.75 and 375 kW.

In the EEA (European Economic Area) IE2 motors cannot be speed controlled by
this standard was the base for the voltage, i.e. voltage transformers.
guideline 2009/640/EU, which defines Systemair is offering a newly developed
minimum efficiencies for motors being range of frequency inverters, FRQ, to fill
sold, installed and operated in this area. this gap, offering a real plug and play
Since 16.6.2011 the minimum efficiency solution – no need for time consuming
class for those motors is IE2. Those mo- configuration at site, and when choos-
tors combine the benefits of a higher ing the FRQ-S models, no need to install
efficiency with a longer lifetime. This expensive shielded cable. Read more on
guideline has had an influence on the www.systemair.com.
Systemair product range. All three phase
IEC motors, used for example in Multibox Another excellent alternative to IE2 high
MUB, roof fans DVN, axial fans AXC and efficiency motors are Systemair fans with
other Systemair products, covered by the EC-motors, offering up to 50% energy
EU guideline have been replaced by high saving. All EC fans are fully speed con-
efficiency IE2 motors. trollable by a simple 0-10V signal. Full
technical details on www.systemair.com.
Efficiency classification IE2 | 15

Systemair EngergyCalc

Systemair EnergyCalc is a soft-


ware for calculating the saving
of energy, energy cost, CO2 and
the payback time for motors in
comparison with energy saving
motors.

On our homepage you can find the


calculator for energy saving by chosing
Support and Software Tools. This
online-service enables you to calculate
the saving of energy, energy costs and
CO2. You can also see the payback
period from motors in comparison to
energy motors.
Compare AC- with EC-motors or IE1
with IE2 and IE2 with IE3 motors and
calculate your engergy saving by using
the new motor technology.
16 | EC-Fans

EC-Fans from Systemair are


Economical and Reliable

The challenge
Energy-saving
Everyone’s talking about climate protec- in this context is to use it more efficient-
tion, and calling for immediate action. ly. Then it will be possible to maintain the More than just hot air!
But what needs to be done? The chal- function, comfort and convenience that
lenge has to be faced by individuals as are part of a modern lifestyle. • In Europe alone, ventilation fans
well as by organisations. If companies consume about 197 000 GWh.
are to take their corporate social respon- Systemair, the ventilation company, of- • This puts them among the larg-
sibility seriously, and consumers are to fers you an opportunity to play an active est electricity users overall.
adopt LOHAS (Lifestyle of Health and part in this process. It has developed a
• Even a 12-15% improvement in
Sustainability), the focus will most simple, effective answer that creates a
efficiency could reduce CO2 emis-
definitely be on sustainable materials win-win situation; in other words you,
sions by 19 million tons.
and efficiency. Avoiding the use of your customer and the environment all
energy is one thing, but the true answer benefit. In other words, companies could
cut annual operating costs by
as much as 2.6 billion Euros by
optimising the motor systems. And

40% 20%
since the use of fans will increase
in the years to come, there is an
obvious need for innovative solu-
tions in the motor area.
Buildings account for EU directive to reduce
40% of the EU´s primary energy use by 20%
energy use by 2020.

Systemair EC-fans are your first choice


Systemair EC-fans are driven by energy- current in the right direction at precisely AC fan drives. Our EC-motors have high
saving EC-motors with built in electronic the right time for accurate motor control. energy-saving potential not only at full
control to keep them running in the EC motors run silently in a controlled load, but especially at part load, where
optimal operating range. They are an operating condition. And they have the loss of efficiency is very much lower
excellent solution for demand-responsive longer service life due to lower winding than with an asynchronous motor with the
ventilation systems. EC-motors are temperatures and lower wearout. EC- same output.
permanent magnet motors where the motors with integrated electronic control
mechanical commutation has been can easily be varied in speed to match air
replaced by electronic circuitry which flow demand. For the same air volume,
supplies the correct amount of armature they consume distinctly less energy than
EC-Fans | 17

Top advantages of fans with EC-motors from Systemair:

1.
Up to 90% higher efficiency than conventional 6. Long service life
systems
7. Low sound level throughout the entire fan
2. Higher efficiency throughout the entire fan perfomance diagram
perfomance diagram
8. All control and protection electronics are
3. Less energy use, resulting in lower energy costs integrated in the motor

4. Less energy use means lower CO2 emissions; 9. Easy electrical connection
lower emissions means lower global warming
10. Ventilation on demand - easy to adjust
5. Easy to control by 0-10 V signal ventilation rate to actual need

Energy efficient ventilation


Energy efficient ventilation is about de- speed ventilation solutions with the
signing the system in a smart way, using help of multiple sensor input that will
fans that have high efficiency and adjust- offer a trickle and boost control and/
ing the ventilation rate to the actual need or a proportional control. By controlling
while keeping a good indoor air quality. high efficiency, EC-driven exhaust and/or
supply fans as well as other components
Systemair’s new EC-Vent greatly simpli- of a ventilation system it promotes new
fies demand-controlled change of levels of comfort and energy use in a
ventilation. EC-Vent is an intelligent wide variety of environments.
controller that provides an effective and Read more on the following pages.
very efficient means of using variable
18 | EC-Vent

EC-Vent
Intelligent Control for Energy Efficient EC-Fans

Demand-controlled ventilation system with KVKE EC and EC-Vent,


based on temperature and CO2 values, combined with timer functions.

Systemair’s EC-Vent raises energy efficiency and indoor Different sensors can be connected to the system, the high-
comfort to new levels. It greatly simplifies demand controlled est value is controlling the system. EC-Vent is easy to install
ventilation. This intelligent controller effectively varies venti- and reduces operating costs. It also provides lower noise
lation speed based on input from multiple sensors: levels and longer service life. The EC-Vent consists of two
units, one central unit to be placed near the fan and a single
• Humidity
display unit normally sited in a room easily accessible to the
!
• CO2 level
NEW user. These units are connected to each other with a low
• Presence detectors
voltage cable.
• Pressure
More detailed information of EC-Vent you can find in our
• Temperatur and
online catalogue www.systermair.com.
• Timer.
EC-Vent | 19

EC-Vent: one controller - many possibilities


Name Art. no.
EC-Vent room unit 3018
built-in humidity and temperature sensors

EC-Vent control board 3115

Room sensor TG-R5/PT1000 5404


Outdoor sensor TG-UH/PT1000 35203
Duct sensor TG-KH/PT1000 202705
Room humidistat/Hygrostat HR1 5150

Timer 5165

Pressure sensor DSG 200 5169


Pressure sensor DSG 500 5170
Pressure sensor DSG 1000 9466

CO2 Transmitter (digital) CO2RT-R-D 6993


CO2 Sensor CO2RT 13704

Presence detector/IR24-P 6995

°C
CO2
%
Presence

Pressure

Temperature
Air quality

Time
Humidity

Su/Wi
Manual

EC-Vent controls the degree of ventilation in buildings to meet different levels of


occupancy as detected by sensors located within the areas to be ventilated. The
result is an indoor climate that always matches building use and occupation.
20 | EC-Fans

We offer you the best range of EC-fans:

prioAir 28 MUB/T EC 148

Circular duct fans Square duct fan Multibox


Air volume up to 0.37 m³/s Air volume up to 4.12 m³/s
for higher temp. of transported air

K EC 32 TFSR/TFSK EC 160

Circular duct fans Roof fans


Air volume up to 0.48 m³/s Air volume up to 0.22 m³/s

KVO EC 48 DVC/DVCI 170

Insulated circular duct fans Roof fans


Air volume up to 0.53 m³/s Air volume up to 3.63 m³/s

KD EC 56 AW sileo EC 202

Circular duct fans Axial fans


Air volume up to 2.77 m³/s Air volume up to 9.72 m³/s

KVKE EC 78 DVG EC 280

Insulated circular duct fans Smoke extract roof fans


Air volume up to 0.52 m³/s Air volume up to 6.98 m³/s

RS/RSI EC 98 KBT/KBR EC 334

Rectangular duct fans Thermo fans


Air volume up to 2.97 m³/s Air volume up to 0.92 m³/s
for higher temp. of transported air

MUB EC 124

Rectangular duct fan Multibox


Air volume up to 3.63 m³/s
Systemair | 21

EC-Fans from Systemair


Energy efficient and environmentally friendly
22 | Other Products from Systemair

Other Products from Systemair


Systemair has an extensive range of ventilation products: fans including smoke extract, tunnel
and car park fans, explosion proof fans, air handling units from large central units to small resi-
dential units with energy recovery, air distribution products, chillers and fire/smoke dampers.
These products are installed in a variety of locations, including homes, offices, healthcare prem-
ises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc.

Air handling units Compact air handling units False ceiling units
Systemair produces a wide range of Compact supply air handling unit with Compact and easy to maintain air han-
air handling units. heating battery and filter for use in petrol dling unit with heat recovery and control
stations, schools, stores, offices and system. Mounted in a false ceiling or in
smaller premises. The units are compact the attic.
in dimensions and are easy to install. Air flow: 20-1500 l/s
Air flow: 20-1400 l/s

Horizontal units Vertical units


A broad range of horizontal air handling A broad range of vertical air handling
units with or without heat recovery. Use- units with or without heat recovery. Use-
able everywhere from smaller premises able everywhere from smaller premises
to schools, stores and larger offices. to schools, stores and larger offices.
Air flow: 20-1500 l/s Air flow: 20-1500 l/s

Residential ventilation Residential units Cooker hoods


Complete energy-efficient air handling For homes with living areas of 60-320 m2. Ideal for capturing odours even at low
units with heat recovery and built-in airflows.
control systems. Designed to be mounted
over the cooker, on walls or horizontally
in attics.
Other Products from Systemair | 23

Fire safety products Fire & smoke dampers


Systemair produces fans, dampers and Dampers that reduce the spread of
control equipment for dual use, i.e. for smoke and fire.
normal operation and certified for use
during normal operation and in the
event of a fire.

Air distribution products Supply, extract & transfer devices Nozzle diffusers
Systemair’s range also includes a wide For mounting in ceilings or walls. Optimum flexibility and comfort in air
selection of air distribution products distribution for rooms
suitable for a variety of applications and
requirements. Development and manu-
facture take place in modern factories
in Slovakia, Sweden and India.

Supply & extract air valves Volume control


For mounting in ceilings and walls. Dampers, plenum boxes, VAV/CAV and
duct accessories.

Chillers & Heat pumps


Systemair, a leading company in HVAC
equipment for ventilation and air
distribution globally, has entered the
air conditioning and refrigeration mar-
ket. The production facility is equipped
with high-tech machinery and has one
of the most modern research centers in
Europe for the development and testing
of Chillers & Heat Pumps.
This includes a wide range from 20
kW to 1700 kW meeting a diverse
range of applications in air condition-
ing and industrial processes. The range
consists of air and water cooled Chillers
and Heat Pumps in condensing and non
condensing models. These are all Eu-
rovent certified.
24 | Good Indoor Climate

A Good Indoor Climate is Vital


We often take natural resources such as fresh air for granted. We must however remain frugal with this
essential resource and mindful of maintaining a responsible balance between the designing of good
ventilation systems and considering energy consumption and well thought out material usage and
production methods. Systemair has recognized this need and has developed the "Green Ventilation"
registered trade mark for labelling these products.

Heat recovery Pressure Quality-certified products


In areas with a relatively low average The design of the duct system and the How can you choose the right solution
annual temperature, ventilation systems unit has an impact on required system and product when there are so many
employ effective heat recovery that pressure. There are often tens, some- alternatives? Nowadays, most major
returns energy from extract air to the times hundreds, of Pascals to be saved suppliers are ISO-certified and have CE-
supply air. A good rotating heat exchang- here. marked products, but is that enough? At
er can recover up to 90% of the energy Systemair we are going one step further
present. Cool recovery and working hard to ensure that our
In warmer parts of the world, energy products maintain a high standard and
Energy-efficient fans savings may be possible by drawing cool are approved by various bodies. For units,
Today, there is a new generation of fan night-time supply air into premises, thus this may mean Eurovent certification or
motors that contribute to a dramatic cooling the building structure. other local certification for the country in
reduction in energy consumption, as question. To achieve this, you need re-
much as 50% in some cases. The new sources and expertise. Within the Group,
EC-motors are better suited to speed you will find, among other things, one
control functions, which is where con- of Europe’s most modern development
siderable energy savings can be made. centres, which is AMCA-certified.
Further benefits are of quieter operation A room that is so quiet that the only
as well as extended product life. thing you’ll hear is your heartbeat.

The development centre in Skinnskatte-


Systemair "sileo" range
berg, recently accredited by AMCA, signi-
Systemair "sileo" ranges: The new fies an investment of EUR 700,000 and
generation of Systemair products with is fitted with measurement and testing
high efficiency and at the same time equipment, making it one of the most
drastically reduced sound levels. A new modern facilities of its kind in Europe.
impeller generation, introduced in various
fan ranges. Read more in our online- The quiet room is one of the test stations
catalogue. or a “reverberation chamber”, producing
a background sound of less than 10 dBA.
When measuring supply air terminals, a
green laser is used to show how the air is
expelled from wall-mounted or ceiling-
mounted devices.

There is also a climate chamber that


cools the air to -20°C, which means we
can use it all year round to develop our
recovery units. In addition to the test
centre in Skinnskatteberg, there are also
test facilities in Germany and Denmark
where we can measure air volumes of
more than 400 000 m3/h.

One of Europe's most modern development centres


Selection Tools | 25

Selection Tools
We have developed this overview to make it easier for you to get an idea of which
product best suits your specific needs. More detailed analysis or planning usually
requires additional information, which is where the following tools come in.

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Curtains and Heating Products | Tunnel Fans
| Tunnel Fans
Heating Products
Curtains and
Fire Safety | Air
on Products |
Units | Air Distributi
Fans | Air Handling

Product catalogue and EC-fans


Energy efficient and environmentally friendly

specification data
Air Handling Units
Catalogue 2012

More detailed technical information,


sufficient to carry out complete plan-
ning, is available in separate catalogues
and specification data. These describe
all incorporated functions, available
accessories, and additional technical
data.
Contact us for printed versions or
download on www.systemair.com.

Online catalogue and computer


software
For those who prefer to work online,
it is possible to select and dimension
most products using Systemair’s online
catalogue.

In addition to complete product


information, there is also a selection
function that suggests alternative
products to suit actual needs. For cer-
tain products, such as Topvex, medium
pressure axial fans, air handling unit DV,
there is computer software that you
can download and install locally.

Personal support
Systemair aims to have local expertise
close to the customer.
You can find up-to-date information
and contact details for each country on
our website, www.systemair.com.
Circular duct

26 | Circular Duct Fans


fans

Circular Duct Fans

10
4

1
5
9 14
18

2
13
8
5
11
7 5
12
5
6 15 17

16

General Systemair range Motors


Systemair circular duct fans have been Systemair offers different variants of Systemair circular duct fans are all
developed for use in compact exhaust circular duct fans. The new prioAir range equipped with external rotor motors,
and supply air systems. The Systemair with an exclusive impeller design offers speed controllable by voltage. All motors
circular duct fan was the first in-line high air volumes with very compact di- are equipped with thermal contacts (TK)
duct fan available on the market in this mensions and the best SFP value on the for effective thermal motor protection.
design. The availability of a compre- market. For systems with higher pressure The TK is internally wired in the ranges
hensive range of accessories, including losses we are offering the ranges K and prioAir, K, KV, RVK and KVKE. Manual re-
heating and cooling coils, filters, silencers RVK. The KV range can be installed di- setting of the TK is in accordance with
and more, offers solutions for complete rectly on the wall. For higher air volumes EN 60335-2-80. The KD, KVK and KVO
systems for almost all applications. Our we offer the KD range with mixed flow ranges are partly equipped with internal-
experience over the past 35 years and impellers. When a low noise level is re- ly wired TK, partly with TK with extended
continuous research and development quired, we are offering the ranges KVK, leads. The TK leads have to be connected
of new products and technologies has KVKE and KVO, all with sound absorbent to an external TK triggering device (see
resulted in the Systemair circular duct insulation. electrical accessories).
fan system being a market leader. Our
motto “the straight way” is revealed in Note: Failure to connect the TK provided
the straight routing of the air in a ducted will result in all warranties being null and
system. void.
fans
Circular duct
Circular Duct Fans | 27

1 IGK Intake grid with wall flange 9 KVK Circular duct fan
and insect mesh
10 KVKE/KVO Circular duct fan,
2 FGR Filter cassette with insulated
panel filter
11 LDC Silencer
3 IGC Intake grid for inside or
12 CB/CBM Electrical heating battery
outside installation
13 VBC Water heating battery
4 FFR Filter cassette for bag filter
14 VBF Water heating battery
with bag filter
5 FK Fast clamp
15 SPI Iris damper
6 RVK Circular duct fan, plastic
16 Elegant Diffuser
7 K Circular duct fan, metal
17 Sinus A Diffuser
8 KD Circular duct fan with
mixed flow impeller 18 Sinus B Diffuser

prioAir NEW!
28 KVO EC NEW!
48 KVK 68

Circular duct fan, plastic, Circular duct fan, insulated, Circular duct fan, insulated
with EC-motor with EC-motor

K EC 32 KVO 52 KVK DUO 74

Circular duct fan, metal, Circular duct fan, insulated Circular twin box duct fan,
with EC-motor insulated

K / KV 36 KD EC NEW!
56 KVKE EC 78

Circular duct fan, metal Circular duct fan, metal, with Circular duct fan, insulated,
mixed flow impeller and with EC-motor
EC-motor
RVK sileo 42 KD 60 KVKE 82

Circular duct fan, plastic Circular duct fan, metal, with Circular duct fan, insulated
mixed flow impeller
Circular duct

28 | Circular Duct Fans


fans

prioAir NEW! Electrical


accessories
The prioAir series is designed for installation in ducts. PrioAir fans
have 25 mm long spigot connections in acc. with EN 1506:1997.
The fans have aerodynamically optimized impellers and guide
vanes with intergrated external rotor motors.
AC version: The fans can be speed-controlled via a stepless MTP 10
thyristor or a 5-step transformer. To protect the motor from over- p. 359
heating the fan has integrated thermal contacts with manual
reset in acc. with EN 60335-2-80. EC version: Easy to control by
0.10V signal. Motor protection is integrated in the electronics of
the motor.
The air tight casing (tightness class C in acc. with EC-Vent
EN12237:2003) is manufactured from special composite mate- p. 365
rial.
• EC-motors, high level of efficiency
The mounting clamp facilitates easy installation and removal,
• Speed-controllable and prevents the transfer of vibrations to the duct. Prio mounting
• Integral thermal contacts bracket to the wall or ceiling as accessory.
• Can be installed in any position For installation in damp locations we recommend to use a run- MTV 1/010
• Compact design on timer. p. 359
• Lowest SFP values and high efficiency
• Low sound level

REV p. 380
Quick selection
Q [m³/h]
0 200 400 600 800 1000 1200 1400
400
13558/13560/13577/13578/13999/14000

1 prio 160E2
350 2 prio 160EC
3 prio 200E2
300
4 prio 200EC
250

200
Ps [Pa]

150

100

50
1 2 3 4
0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4
Q [m³/s]

Technical data More sizes of prioAir coming soon.


prioAir 160 E2 160 EC 200 E2 200 EC
Art. no. 36916 36917 36381 36380
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~
Power W 26.3 76.6 71.7 117
Current A 0.12 0.676 0.33 0.921
Max. air flow m3/s 0.12 0.224 0.263 0.37
SFP KW/(m3/s) 0.3 0.4 0.4 0.4
0.07 m3/s/150 Pa 0.19 m3/s/150 Pa 0.17 m3/s/150 Pa 0.29 m3/s/180 Pa
R.p.m. min -1
2458 4311 2563 3463
Max. temp. of transported air °C 55 55 55 55
Sound pressure level at 3 m dB(A) 34 38 44 50
Weight kg 1.4 1.6 3.1 2.4
Insulation class, motor F B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44
Capacitor µF 0.7 - 1.5 -
Motor protection Integral Integral Integral Integral
Speed control, stepless Electronic REE 1 MTP 10 REE 1 MTP 10
Wiring diagram p. 442-461 56 57 56 57
fans
Circular duct
Circular Duct Fans | 29

Dimensions Ventilation
accessories
B
C
ØE D D

CB p. 393

ØA
ØA
FFR p. 391

F FGR p. 392

prioAir ØA B C D ØE F
prio mounting
160 E2/EC 159 220 170 25 182 211
bracket p. 389
200 E2/EC 199 245 195 25 227 249

FK p. 388

IGC p. 388

IGK p. 388

LDC p. 390

RSK p. 388

SG p. 389

VK p. 389

VKK p. 392

Space-saving: Thanks to its compact


dimensions the circular duct fan matches VBC p. 395
the duct dimensions. A lean inline solution.

VBF p. 396

CWK p. 398
Circular duct

30 | Circular Duct Fans


fans

Performance

Q [m³/h] Q [m³/h]
0 100 200 300 400 500 0 200 400 600 800
120 400

14000

13999
prio 160E2 prio 160EC
100

300
80
Ps [Pa]

Ps [Pa]
60 200

40

100
20

1 2 3 4 5 1 2 3 4 5
0 0
0 0.04 0.08 0.12 0.16
Q [m³/s] Q [m³/s]
40 100
5 5

P [W]
P [W]

20 50
1 2
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 59 43 50 54 54 51 48 41 29 LwA Inlet 74 43 53 67 67 70 67 62 53
LwA Outlet 57 43 51 45 54 48 46 40 29 LwA Outlet 70 41 53 59 64 65 62 59 53
LwA Surrounding 38 17 22 22 35 33 30 18 2 LwA Surrounding 56 10 26 37 50 53 50 42 28
Measurement point: 0.078 m³/s @ 75 Pa Measurement point: 0.13 m³/s @ 269 Pa

Q [m³/h] Q [m³/h]
0 200 400 600 800 1000 0 200 400 600 800 1000 1200 1400
250 400
13577/13578

13558/13560
prio 200 E2 prio 200EC
350
200
300
77

150 70 250
Ps [Pa]
Ps [Pa]

200
67 71
100
70 150
77
62
67 100 70
50 63
58 62
59 50 61
49
51 52
52
1 2 3 4 5 1 2 3 4
0 0

Q [m³/s] Q [m³/s]

100 200
5 4
P [W]
P [W]

50 100
2
1
0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 37 50 65 65 63 60 55 46 LwA Inlet 77 45 54 70 71 73 69 64 56
LwA Outlet 65 36 49 56 61 59 58 54 46 LwA Outlet 72 43 54 58 67 68 65 61 56
LwA Surrounding 50 12 22 33 47 45 42 31 19 LwA Surrounding 59 13 27 38 52 56 53 45 32
Measurement point: 0.17 m³/s @ 144 Pa Measurement point: 0.219 m³/s @ 273 Pa
fans
Circular duct
Circular Duct Fans | 31

Efficient, compact, low-noise NEW!

prioAir

The most important advantages at a glance

 Lowest SFP values and very high  


Material: Special composite
efficiency. Your advantage: Maxi- material. Your advantage:
mum performance and low energy Corrosion proof, lower weight,
consumption quick and easy to install

 Powerful EC motor with integrated  


Low-noise
electronics. Your advantage:
Reduced energy consumption  
Long life
reduces the running costs

 Compact design. Your advantage:


Little space required, a real inline
fan
Clever: The optimised shape of the impeller
enables an ideal air stream.

High performance, low power consumption


SFP values and efficiency of prioAir 200EC

Efficiency (%) Fan characteristics SFP (kW/m3/s)

4,2 400
4 380 Efficiency (%)
3,8 50
360
3,6 340 Fan characteristics
45
3,4 320
3,2 300
40
3 280
2,8 35 260
2,6 240
SFP (kW/m3/s)

2,4 30 220
E (%)

psf (Pa)

2,2
200
2 25 180
1,8
160
1,6 20
1,4 140
1,2 15 120
1 100
0,8 10 80 SFP (kW/m3/s)
0,6 60
0,4 5 40
0,2 20

0 0 0 100 200 300 400 500 600 700 800 900 1000 1.100 1.200 1.300 1.400
qv (m3/h)
Convincing: Peak values in all disciplines
Circular duct

32 | Circular Duct Fans


fans

K EC Electrical
accessories
• EC-motors, high level of efficiency
• 100% speed controllable
• Integrated motor protection
• Supplied with mounting bracket
MTP 10
The K EC series is designed for installation in ducts. All the K-fans p. 359
have minimum 25 mm long spigot connections. The fans have
backward curved blades and external rotor motors (EC). The FK
mounting clamp facilitates easy installation and removal, and
prevents the transfer of vibration to the duct.
The fans are delivered with a pre-wired potentiometer(0-10V) EC-Vent
that allows you to easily find the desired working point. Motor p. 365
protection is integrated in the electronics of the motor.
The casing is manufactured from galvanized sheet steel with
the seams folded to give the fan a close to air tight casing. Out-
door mounting and wet room applications are possible due to the
fans air tight casing and the IP 55 rated terminal box with a IP 68 MTV 1/010
rated M20 cable gland. p. 359

Quick selection
qv [m3/h]
REV p. 380
1 K 100 EC
2 K 125 EC
3 K 160 EC
4 K 200 EC
5 K 250 EC
6 K 315 M EC
7 K 315 L EC
2

4 5 6 7
1 3

qv [m3/s]

NEW! NEW!
Technical data
K 100 EC 125 EC 160 EC 200 EC 250 EC 315 M EC 315 L EC
Art. no. 16955 16956 2580 2581 2583 2584 2585
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 82.6 83 79.4 78.6 120 166 340
Current A 0.69 0.68 0.63 0.63 0.92 1.14 2.08
Max. air flow m3/s 0.0891 0.134 0.151 0.215 0.287 0.393 0.481
R.p.m. min-1 3479 3308 3105 2468 2628 2113 2719
Max. temp. of transported air °C 60 60 60 60 40 40 55
“ when speed controlled °C 60 60 60 60 40 40 55
Sound pressure level at 3 m dB(A) 49.8 46 47 51 45.6 50 57
Weight kg 2.9 2.8 3.3 3.3 3.9 6 7.2
Insulation class, motor B B B B B B B
Enclosure class, motor 54 54 IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection Integral Integral Integral Integral Integral Integral Integral
Speed control, stepless Electronic MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10
Wiring diagram p. 442-461 41 41 41 41 41 41 41
fans
Circular duct
Circular Duct Fans | 33

Dimensions Ventilation
accessories
øB
øA
40
E

FK p. 388
(F)

88
SG p. 389
C

øA

VK p. 389
⌀A ⌀B C D E (F)
K 100 EC 99 218 26 166 26 218
K 125 EC 124 218 27 142 27 196
K 160 EC 159 286 25 147 26 198
K 200 EC 199 336 30 148 27 205 RSK p. 388
K 250 EC 249 336 30.5 144.5 27 202
K 315 M EC 314 408 32.5 160.5 27 220
K 315 L EC 314 408 37.5 160.5 27 225
LDC p. 390

FFR p. 391

CB p. 393
Circular duct

34 | Circular Duct Fans


fans

Performance
Q [m³/h] Q [m³/h]
0 100 200 300 0 100 200 300 400 500
800 800

13480/13481

13482/13483
K 100 EC K 125 EC

600 600

75
77
Ps [Pa]

Ps [Pa]
400 400
67
68
77
200 200 76
55 64 58
70
58 58
43 49 41 42
0 0
0 0.03 0.06 0.09 0 0.04 0.08 0.12 0.16
Q [m³/s] Q [m³/s]
100 100
75 75
P [W]

P [W]
50 50
25 25
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 55 72 69 75 70 66 59 50 LwA Inlet 79 53 64 75 73 71 66 61 53
LwA Outlet 77 56 71 66 71 70 66 60 50 LwA Outlet 77 52 65 73 72 68 66 60 52
LwA Surrounding 57 12 21 36 53 52 49 46 34 LwA Surrounding 53 16 13 39 48 48 45 44 34
Measurement point: 0.0401 m³/s @ 480 Pa Measurement point: 0.0538 m³/s @ 423 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 53 72 73 73 69 66 56 46 LwA Inlet 77 51 70 68 73 68 63 55 47
LwA Outlet 78 59 71 73 72 67 64 57 46 LwA Outlet 75 49 70 68 70 64 62 57 46
LwA Surrounding 54 22 27 39 50 48 47 40 29 LwA Surrounding 58 24 38 45 57 50 45 39 29
Measurement point: 0.068 m³/s @ 381 Pa Measurement point: 0.107 m³/s @ 275 Pa
fans
Circular duct
Circular Duct Fans | 35

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 52 64 68 68 66 61 54 44 LwA Inlet 76 53 70 67 70 69 65 65 60
LwA Outlet 73 52 62 66 66 66 65 63 61 LwA Outlet 76 54 72 68 66 68 66 62 56
LwA Surrounding 52 15 35 40 49 46 44 34 23 LwA Surrounding 57 24 33 48 52 49 50 48 36
Measurement point: 0.129 m³/s @ 353 Pa Measurement point: 0.177 m³/s @ 325 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 67 74 74 78 75 71 69 67
LwA Outlet 82 65 74 75 75 75 75 72 66
LwA Surrounding 64 47 45 58 61 54 54 52 44
Measurement point: 0.217 m³/s @ 612 Pa
Circular duct

36 | Circular Duct Fans


fans

K / KV Electrical
accessories
• Speed controllable
• Integral thermal contacts
• Can be installed in any position
• Can be installed outdoors
• Maintenance-free and reliable RE p. 356

The K series is designed for installation in ducts and the KV is de-


signed to be used as a wall mounted duct-connected extract fan.
All the K/KV-fans have a minimum 25 mm long spigot connections.
The fans have backward curved blades and external rotor motors.
To simplify installation the K-fan has a fixing bracket together with REU p. 356
screws for mounting the bracket included as standard.
The FK mounting clamp facilitates easy installation and removal,
and prevents the transfer of vibration to the duct. The fans can be
speed-controlled via a stepless thyristor or a 5-step transformer.
To protect the motor from overheating K/KV 100 M and 125 M is
impedance protected, K/KV 100 XL-315 has integral thermal con- REE p. 357
tacts with electrical reset.
The casing is manufactured from galvanized sheet steel and fold-
ed which gives the fan an air tight casing. Duct connected outdoor
and wet room applications of the fan are possible due to the air tight
casing.
Quick selection REV p. 380
5961, 4115, 5994, 4110, 4218, 4506, 3986, 4501

4401, 4398, 4427, 4453, 6112


1 K/KV 100M 1 K/KV 200M
2 K/KV 100XL
2 K/KV 200L
3 K/KV 125M
4 K/KV 125XL
3 K/KV 250M
5 K/KV 150 M 4 K/KV 250L
6 K/KV 150 XL 5 K/KV 315M
7 K/KV 160M 6 K/KV 315L
8 K/KV 160XL

4
3 2
1 5
6
3
1 2 4 5 7 6 8

Technical data
K/KV 100 M 100 XL 125 M 125 XL 150 M 150 XL 160 M
Art. no. 1001/1205 1004/1207 1002/1208 1003/1210 1017/1211 1018/1212 1005/1213
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 29.9 58.6 29.1 62 61 104 59
Current A 0.171 0.253 0.172 0.271 0.264 0.458 0.259
Max. air flow m /s 0.051
3
0.074 0.057 0.0978 0.122 0.199 0.136
R.p.m. min-1 2443 2425 2483 2390 2412 2567 2499
Max. temp. of transported air °C 70 70 70 70 70 70 70
“ when speed controlled °C 70 70 70 70 70 70 70
Sound pressure level at 3 m dB(A) 38 48 34 50 42 55 44
Weight kg 2.5 2.5 2.5 2.5 3.5 4.5 3
Insulation class, motor B B B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF – 2 – 2 2 3 2
Motor protection Integral Integral Integral Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 1 REE 1 REE 1
Wiring diagram p. 442-461 1 2 1 2 2 2 2
fans
Circular duct
Circular Duct Fans | 37

Dimensions Ventilation
accessories
øB K ⌀A ⌀B C D E (F)
øA 100 M 99 218 26 166 26 218
40
100 XL 99 246 26 161 26 213
E

125 M 124 218 27 142 27 196 FK p. 388


125 XL 124 246 26 151 26 203

88
(F)

150 M 149 286 25 152 25 202


150 XL 149 336 29 171 26 226
C

øA 160 M 159 286 25 147 26 198 SG p. 389


160 XL 159 336 29 166 26 221
200 M 199 336 30 148 27 205
200 L 199 336 30 174 27 231
250 M 249 336 30.5 119.5 27 177
250 L 249 336 30.5 144.5 27 202
315 M 314 408 32.5 160.5 27 220 VK p. 389
315 L 314 408 37.5 160.5 27 225

KV ⌀A ⌀B C D £E £F
100 M 99 218 26 143 254 284
40 RSK p. 388
100 XL 99 246 26 125 304 334
125 M 124 218 27 131 254 284
5

125 XL 124 246 26 127 304 334


150 M 149 286 25 113 344 374
LDC p. 390
D

150 XL 149 336 29 147 394 425


160 M 159 286 25 113 344 374
C

øA 160 XL 159 336 29 147 394 425


øB 200 M 199 336 30 134 394 425
200 L 199 336 30 158 394 425
E
250 M 249 336 30.5 135 394 425
F FFR p. 391
250 L 249 336 30.5 159 394 425
315 M 314 408 32.5 145 458 489
315 L 314 408 37.5 145 458 489

CB p. 393

K/KV 160 XL 200 M 200 L 250 M 250 L 315 M 315 L


Art. no. 1006/1214 1007/1215 19510/19518 1009/1217 19512/19519 19516/19521 19514*/19520*
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 105/106 106/102 145/143 104/103 145/148 201 318/310
Current A 0.457 0.463/0.453 0.631/0.628 0.453/0.451 0.632/0.648 0.882 1.39/1.35
Max. air flow m3/s 0.214/0.232 0.216/0.219 0.268/0.272 0.216/0.219 0.272/0.273 0.344/0.351 0.48
R.p.m. min -1
2553 2551 2555 2566/2575 2562/2556 2520/2506 2318/2367
Max. temp. of transported air °C 70 70 70 70 70 70 57.4/50.7
“ when speed controlled °C 70 70 70 70 70 70 52.4/45.4
Sound pressure level at 3 m dB(A) 53/48 51/49 48/49 49/51 43/47 46.5/43 50/51
Weight kg 4.1/3.9 4.2/3.9 4.8/4.5 4.0/3.9 4.6 5.5 6.6
Insulation class, motor B B F B F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF 3 3 3.5 3 3.5 5 7
Motor protection Integral Integral Integral Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 3 RE 3 RE 1.5 RE 1.5
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 3 REU 3 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 1 REE 2 REE 2
Wiring diagram p. 442-461 2 2 2 2 2 2 2
* Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Circular duct

38 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 48 59 56 58 50 47 40 28 LwA Inlet 72 49 64 68 66 62 55 52 41
LwA Outlet 60 32 54 55 55 50 44 38 26 LwA Outlet 69 49 62 63 65 60 55 54 44
LwA Surrounding 46 18 14 24 36 41 43 29 16 LwA Surrounding 55 28 28 47 51 48 46 44 30
Measurement point: 0.0255 m³/s @ 96.3 Pa Measurement point: 0.037 m³/s @ 215 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 59 33 51 54 55 48 45 37 29 LwA Inlet 73 55 65 68 69 65 61 52 41
LwA Outlet 60 40 46 58 55 47 44 39 31 LwA Outlet 73 55 64 68 68 64 61 57 50
LwA Surrounding 41 12 9 24 39 33 33 25 18 LwA Surrounding 57 35 31 46 53 52 49 41 29
Measurement point: 0.0282 m³/s @ 98.9 Pa Measurement point: 0.044 m³/s @ 202 Pa
fans
Circular duct
Circular Duct Fans | 39

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 45 63 66 64 58 55 51 43 LwA Inlet 78 56 66 74 74 67 62 62 54
LwA Outlet 69 46 63 66 60 56 52 50 41 LwA Outlet 76 50 66 73 70 65 62 60 48
LwA Surrounding 49 24 25 43 46 40 39 36 24 LwA Surrounding 62 25 27 43 61 47 49 50 36
Measurement point: 0.0612 m³/s @ 208 Pa Measurement point: 0.0996 m³/s @ 265 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 43 64 64 65 62 59 48 37 LwA Inlet 77 49 65 72 73 67 63 63 51
LwA Outlet 68 44 63 64 61 59 56 49 37 LwA Outlet 75 47 65 72 68 65 63 62 50
LwA Surrounding 51 13 23 36 47 43 46 38 23 LwA Surrounding 60 24 31 41 59 46 46 49 35
Measurement point: 0.0612 m³/s @ 220 Pa Measurement point: 0.0965 m³/s @ 276 Pa
Circular duct

40 | Circular Duct Fans


fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 47 67 67 72 65 61 59 50 LwA Inlet 69 42 62 63 62 63 60 53 49
LwA Outlet 74 45 65 69 68 63 62 61 50 LwA Outlet 69 50 62 60 63 62 60 54 49
LwA Surrounding 58 16 40 39 54 49 52 52 37 LwA Surrounding 55 12 25 40 47 52 49 45 40
Measurement point: 0.108 m³/s @ 277 Pa Measurement point: 0.134 m³/s @ 344 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 45 59 61 65 62 60 62 53 LwA Inlet 70 41 61 65 62 63 59 55 50
LwA Outlet 70 46 58 62 64 61 63 62 51 LwA Outlet 68 52 60 58 61 62 61 54 49
LwA Surrounding 56 18 31 31 48 44 51 52 39 LwA Surrounding 50 15 30 43 46 44 41 35 28
Measurement point: 0.108 m³/s @ 246 Pa Measurement point: 0.15 m³/s @ 315 Pa
fans
Circular duct
Circular Duct Fans | 41

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 50 57 62 62 64 62 63 53 LwA Inlet 76 55 66 70 70 68 66 63 58
LwA Outlet 70 51 55 62 60 63 65 64 53 LwA Outlet 77 62 67 71 69 70 70 63 57
LwA Surrounding 54 18 21 40 46 41 48 50 38 LwA Surrounding 57 24 37 45 52 48 51 46 46
Measurement point: 0.189 m³/s @ 380 Pa Measurement point: 0.216 m³/s @ 419 Pa
Circular duct

42 | Circular Duct Fans


fans

RVK sileo Electrical


accessories
• Speed controllable
• Integral thermal contacts
• Can be installed in any position
• Inclusive mounting bracket
• Maintenance-free and reliable RE p. 356

The RVK sileo series is designed for installation in ducts. The casing
is manufactured from PP fibreglass reinforced plastic which gives
the fan a low leakage casing. Duct connected wet room applica-
tions of the fan are possible due to the air tight casing and the IP 44
rated terminal box. We recommend a period of continued ventilation REU p. 356
with dry air for wet room applications.The fans have high effective
backward curved blades (* BAT with special geometry) and external
rotor motors. The FK mounting clamp facilitates easy installation and
removal, and prevents the transfer of vibration to the duct. The fans
can be speed-controlled via a stepless thyristor or a 5-step trans-
former. To protect the motor from overheating the models have inte- REE p. 357
grated thermal contacts with automatic reset.

* BAT = Best Available Technology

Quick selection
REV p. 380
5156, 5136, 5541, 5403, 5429, 5231, 5414

5602, 5607, 5618, 5640, 6694, 5648


1 RVK 100E2 1 RVK 200E2
2 RVK 125E2 2 RVK 200E2-L
3 RVK 125E2-L 3 RVK 250E2
4 RVK 150E2 4 RVK 250E2-L
5 RVK 150E2-L 5 RVK 250E2-XL
6 RVK 160E2 6 RVK 315E2
7 RVK 160E2-L

1 2 3 4 5 7 1 2 4 5 6
3
6

Technical data
RVK sileo 100E2 125E2 125E2-L 150E2 150E2-L 160E2 160E2-L
Art. no. 5755 5756 30331 30336 30341 30338 30342
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 29.1 29.2 58.8 59.6 109 59.2 106
Current A 0.171 0.172 0.26 0.262 0.5 0.261 0.461
Max. air flow m3/s 0.0512 0.0612 0.0898 0.119 0.2 0.121 0.203
R.p.m. min-1 2482 2469 2494 2437 2527 2459 2557
Max. temp. of transported air °C 70 70 70 70 70 70 70
“ when speed controlled °C 70 70 70 70 70 70 70
Sound pressure level at 3 m dB(A) 35 38 43 41 45 41 44
Weight kg 1.8 1.8 2.2 2.6 3.1 2.7 3.2
Insulation class, motor B B B B F B F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF – – 2 2 3 2 3
Motor protection Integral Integral Integral Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 1 REE 1 REE 1
Wiring diagram p. 442-461 1 1 2 2 2 2 2
fans
Circular duct
Circular Duct Fans | 43

Dimensions Ventilation
accessories
øC
øA

FK p. 388

H
E
SG p. 389

I G
F

øB
J
VK p. 389
RVK sileo øA øB øC D E F G H I J
100 99 99 251 30 230 30 271.5 265 60 200
125 124 124 251 30 230 30 271.5 265 60 200
150 149 149 340.5 30 230 30 271.5 360 60 200
160 159 159 340.5 30 230 30 271.5 360 60 200 RSK p. 388
200 199 199 340.5 30 230 30 271.5 360 60 200
250E2-L 249 249 340.5 30 250 30 271.5 360 60 200
250E2, XL 249 249 340.5 30 230 30 271.5 360 60 200
315E2 314 314 405 30 275 30 271.5 430 60 200
LDC p. 390

FFR p. 391

CB p. 393

RVK sileo 200E2 200E2-L 250E2 250E2-L 250E2-XL 315E2


Art. no. 36092 36094 36093 36095 36096 36097
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 104 153 109 159 208 202
Current A 0.46 0.672 0.476 0.691 0.911 0.887
Max. air flow m3/s 0.221 0.28 0.239 0.3 0.363 0.382
R.p.m. min-1 2495 2533 2518 2531 2523 2538
Max. temp. of transported air °C 70 70 70 70 70 70
“ when speed controlled °C 70 55 70 70 55 70
Sound pressure level at 3 m dB(A) 42 45 40 42 42 45
Weight kg 3.2 3.8 3.3 3.8 4.4 5.1
Insulation class, motor F F F F B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF 3 4 3 4 5 5
Motor protection Integral Integral Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 1 REE 1
Wiring diagram p. 442-461 2 2 2 2 2 2
Circular duct

44 | Circular Duct Fans


fans

Performance

RVK sileo 100E2 RVK sileo 125E2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 62 39 57 57 57 51 44 39 27 LwA Inlet 63 36 56 57 60 52 46 41 33
LwA Outlet 57 42 52 52 51 47 44 40 28 LwA Outlet 60 36 54 57 53 50 47 42 33
LwA Surrounding 42 1 11 30 37 37 34 25 14 LwA Surrounding 45 12 15 28 42 38 36 27 28
Measurement point: 0.0256 m³/s @ 99.9 Pa Measurement point: 0.0306 m³/s @ 96.3 Pa

RVK sileo 125E2-L RVK sileo 150E2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 45 58 63 62 60 57 51 41 LwA Inlet 65 43 53 58 59 60 56 50 39
LwA Outlet 67 51 58 62 61 57 54 49 39 LwA Outlet 63 43 54 57 56 57 51 47 37
LwA Surrounding 50 12 25 32 43 46 46 36 24 LwA Surrounding 48 14 10 27 42 44 41 30 21
Measurement point: 0.0404 m³/s @ 201 Pa Measurement point: 0.0715 m³/s @ 183 Pa
fans
Circular duct
Circular Duct Fans | 45

RVK sileo 150E2-L


RVK sileo 160E2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 44 60 63 63 63 59 55 46 LwA Inlet 66 42 58 58 59 60 58 51 41
LwA Outlet 68 47 60 63 61 63 58 52 44 LwA Outlet 64 51 57 56 56 58 55 51 40
LwA Surrounding 52 12 21 30 46 49 46 37 25 LwA Surrounding 48 14 25 30 43 44 43 30 23
Measurement point: 0.11 m³/s @ 251 Pa Measurement point: 0.0666 m³/s @ 191 Pa

RVK sileo 200E2


RVK sileo 160E2-L

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 46 63 62 63 63 61 57 47 LwA Inlet 68 41 58 60 62 61 61 56 48
LwA Outlet 68 48 62 59 63 60 58 53 46 LwA Outlet 66 47 55 54 60 58 59 56 50
LwA Surrounding 51 17 28 28 44 48 46 35 23 LwA Surrounding 49 17 27 33 45 43 43 37 27
Measurement point: 0.101 m³/s @ 259 Pa Measurement point: 0.121 m³/s @ 215 Pa
Circular duct

46 | Circular Duct Fans


fans

RVK sileo 200E2-L RVK sileo 250E2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 45 58 61 62 65 62 55 47 LwA Inlet 67 49 58 62 60 59 58 54 48
LwA Outlet 69 48 56 59 61 63 64 56 48 LwA Outlet 65 46 57 57 58 57 59 54 49
LwA Surrounding 52 17 27 36 44 49 47 34 25 LwA Surrounding 47 28 31 38 43 41 38 34 26
Measurement point: 0.14 m³/s @ 332 Pa Measurement point: 0.143 m³/s @ 229 Pa

RVK sileo 250E2-XL


RVK sileo 250E2-L

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 46 58 69 60 65 58 54 47 LwA Inlet 71 45 60 68 62 62 60 56 48
LwA Outlet 67 49 57 57 59 64 59 54 45 LwA Outlet 69 55 59 63 63 61 62 57 49
LwA Surrounding 49 16 30 43 40 46 39 30 21 LwA Surrounding 49 13 26 44 43 42 41 35 26
Measurement point: 0.165 m³/s @ 319 Pa Measurement point: 0.182 m³/s @ 357 Pa
fans
Circular duct
Circular Duct Fans | 47

RVK sileo 315E2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 49 56 64 63 63 61 56 50
LwA Outlet 69 49 55 62 58 62 65 58 53
LwA Surrounding 52 20 22 48 48 45 42 32 27
Measurement point: 0.21 m³/s @ 359 Pa
Circular duct

48 | Circular Duct Fans


fans

KVO EC NEW! Electrical


accessories
• EC-motors, high level of efficiency
• 100% speed controllable
• Low noise level
• Integrated motor protection EC-Vent
• Potentiometer included for ease of commissioning p. 365

The KVO EC 100-160 models have a single-inlet centrifugal fan


with forward curved blades and a maintenance-free external
rotor motor (EC).
KVO EC 200-315 models have a single-inlet centrifugal fan
with backward curved blades and a maintenance-free external MTP p. 359
rotor motor (EC). These fans develop relatively high static
pressure and have a very high efficiency. The fans are delivered
with a pre-wired potentiometer (0-10V) that allows you to easily
find the desired working point.
The motor and impeller are mounted on the access cover for MTV p. 359
ease of maintenance. The service cover can be easily removed
by withdrawing the hinge pin. Motor protection is integrated in
the electronics of the motor. The fans can be installed in any
position and are easy to connect to spiral ducts using FK mount-
ing clamps. The KVO EC models are manufactured from galva-
nized sheet steel and the lid is insulated with 40 mm rockwool. REV p. 380

Quick selection
11327,11340,11317,11323,11338,11349

1 KVO 100 EC
2 KVO 125 EC
3 KVO 160 EC
4 KVO 200 EC
5 KVO 250 EC
6 KVO 315 EC

1 2 3 4 5 6

Technical data
KVO EC 100 EC 125 EC 160 EC 200 EC
Art. no. 11542 11544 11545 11546
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~
Power W 60.4 111 116 123
Current A 0.48 0.86 0.89 0.96
Max. air flow m³/s 0.09 0.13 0.15 0.24
Fan impeller speed r.p.m. 2499 2724 2411 2577
Sound pressure level in 3 m (20m² Sabine) dB(A) 43 48 48 51
Weight kg 5.6 5.6 6 10.3
Insulation class, motor B B F B
Enclosure class, motor IP 44 44 44 44
Max. temp transported air °C 60 60 60 60
“ when speed controlled °C 60 60 60 60
Wiring diagram p. 442-461 41 41 41 41
fans
Circular duct
Circular Duct Fans | 49

Dimensions Ventilation
accessories

FK p. 388

F
SG p. 389

øA
D

E B
H G C
VK p. 389

KVO EC ⌀A B C D E F G H
100 100 329 367 69 76 300 150 150
125 125 329 367 84 72 300 150 150
160 160 329 367 99 90 300 185 185
RSK p. 388
200 200 419 466 123 109 435 220 220
250 250 528 612 151 133 558 270 270
315 315 614 700 183 164 615 344 260

LDC p. 390

FGR p. 392

CB p. 393

KVO EC 250 EC 315 EC


Art. no. 11547 11548
Voltage/Frequency V/50 Hz 230 1~ 230 1
Power W 312 331
Current A 1.91 2.04
Max. air flow m³/s 0.417 0.528
Fan impeller speed r.p.m. 2799 2264
Sound pressure level in 3m (20m² Sabine) dB(A) 57 55
Weight kg 20.4 25.6
Insulation class, motor F F
Enclosure class, motor IP 44 44
Max. temp transported air °C 60 60
“ when speed controlled °C 60 60
Wiring diagram p. 442-461 41 41
Circular duct

50 | Circular Duct Fans


fans

Performance

Q [m³/h] Q [m³/h]
0 100 200 300 0 200 400
400 500

11340/11341
11327/11328
KVO 100 EC KVO 125 EC
400 69
300

62
300
65

[Pa]
[Pa]

200
63 70

200
56
64
66
64
100
58
100 53
56

54
57
43 48
47 55
0 0
0 0.03 0.06 0.09 0 0.04 0.08 0.12 0.16
Q [m³/s] Q [m³/s]
100 120
10V
90
[W]

[W ]
60
30 4,5V

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 65 52 56 59 58 57 56 52 43 LwA Inlet 70 59 60 65 63 61 59 56 49
LwA Outlet 70 53 63 61 62 64 63 56 47 LwA Outlet 77 58 69 68 68 70 69 63 57
LwA Surrounding 50 16 32 40 41 46 45 38 28 LwA Surrounding 55 34 35 50 46 49 47 40 31
Measurement point: 0.0476 m³/s @ 244 Pa Measurement point: 0.0657 m³/s @ 378 Pa

Q [m³/h] Q [m³/h]
0 200 400 0 300 600 900
800 800
11317/11318

11323/11324
KVO 160 EC KVO 200 EC

600 600

72
[Pa]

[Pa]

400 400

72

72

200 63 200 65
75
65
54 58 69
56
49 48 61
47 47
0 0
0 0.04 0.08 0.12 0.16 0 0.1 0.2 0.3
Q [m³/s]
Q [m³/s]
120 160

90 120
[W]

80
[W]

60
30 40

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 50 66 66 63 62 61 59 53 LwA Inlet 72 50 59 68 65 64 61 57 47
LwA Outlet 75 56 64 69 67 66 68 64 57 LwA Outlet 80 54 61 78 72 71 69 63 53
LwA Surrounding 56 31 43 51 48 49 47 42 35 LwA Surrounding 58 30 42 52 52 53 47 39 28
Measurement point: 0.0759 m³/s @ 417 Pa Measurement point: 0.121 m³/s @ 308 Pa
fans
Circular duct
Circular Duct Fans | 51

Q [m³/h] Q [m³/h]
0 400 800 1200 1600 2000 0 500 1000 1500 2000
1000 1000

11349/11351
11338/11339
KVO 250 EC KVO 315 EC

750 750

79
81

[Pa]
500
[Pa]

500

76
71 79 83
250 250
79
62 73
66
63 52 70
53 55
50
0 0
0 0.2 0.4 0.6 0 0.2 0.4 0.6
Q [m³/s]
Q [m³/s]
400 400

300
300

[W]
200
[W]

200
100
100
0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 60 67 67 70 70 69 67 60 LwA Inlet 76 58 72 70 67 67 67 64 60
LwA Outlet 84 63 73 76 80 77 76 70 63 LwA Outlet 83 63 72 80 75 72 71 66 61
LwA Surrounding 64 43 51 55 61 57 54 50 43 LwA Surrounding 62 39 54 58 58 52 49 44 39
Measurement point: 0.229 m³/s @ 561 Pa Measurement point: 0.264 m³/s @ 523 Pa
Circular duct

52 | Circular Duct Fans


fans

KVO Electrical
accessories
• Speed controllable
• Integral thermal contacts
• Low sound level
• Compact construction
RE p. 356
KVO has a single-inlet centrifugal fan (size 100-160 and size 355-
400 with forward curved blades, size 200-315 with backward
curved blades and a maintenance-free external rotor motor. In all
KVO models, the motor and impeller are mounted on the cover for
easy cleaning and maintenance.
To protect the motor from overheating, the KVO 100-315 have REU p. 356
integral thermal contacts with electrical reset, size 355-400 with in-
tegral thermal contact with external leads for connection to a TK trig-
gering device. The fans can be installed in any position, and are easy
to connect to spiral ducts using FK mounting clamps.
The lid is insulated with 40 mm rockwool. The casing is manufac-
tured from galvanized sheet steel. REE p. 357

Quick selection

REV p. 380
3103, 3009, 3023, 3913

3045, 8215, 8985, 9000


1 KVO 100
1 KVO 250L
2 KVO 125
3 KVO 160L
2 KVO 315L
4 KVO 200 3 KVO 355
4 KVO 400

3
4

1 2
1 2 3 4

Technical data
KVO 100 125 160L 200 250** 315**
Art. no. 2075 2020 2024 19527 19528 19529
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 77.9 89 135 141 301 549
Current A 0.346 0.393 0.59 0.624 1.33 2.38
Max. air flow m /s 0.0778
3
0.101 0.138 0.249 0.417 0.592
R.p.m. min-1 2438 2175 2544 2564 2480 2227
Max. temp. of transported air °C 60 64 70 70 48 48
“ when speed controlled °C 60 64 70 70 43 41
Sound pressure level at 3 m dB(A) 40 38 43 51 52 56
Weight kg 5.6 5.5 6.7 11.2 19 24.3
Insulation class, motor B B B F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF 2 2 4 3.5 7 10
Motor protection Integral Integral Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 3
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 2 REE 4
Wiring diagram p. 442-461 2 2 2 2 2 2
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
fans
Circular duct
Circular Duct Fans | 53

Dimensions Ventilation
accessories

FK p. 388

F
SG p. 389

øA
D

E B
VK p. 389
C
H
G

KVO ⌀A B C D E F G H
100 100 329 367 69 76 300 150 150
125 125 329 367 84 72 300 150 150
160 160 329 367 99 90 300 185 185 RSK p. 388
200 200 419 466 123 109 435 220 220
250 250 528 612 151 133 558 270 270
315 315 614 700 183 164 615 344 260
355 355 572 661 209 231 640 425 600
LDC p. 390
400 400 572 653 221 209 640 425 600

FGR p. 392

CB p. 393

KVO 355 400


Art. no. 2030 2031
Voltage/Frequency V/50 Hz 230 1~ 230 1~
Power W 1196 1257
Current A 5.69 5.95
Max. air flow m3/s 0.882 0.893
R.p.m. min-1 1118 1075
Max. temp. of transported air °C 65 58
“ when speed controlled °C 65 58
Sound pressure level at 3 m dB(A) 53 56
Weight kg 38.3 37
Insulation class, motor F F
Enclosure class, motor IP 54 IP 54
Capacitor µF 20 20
Motor protection S-ET 10 S-ET 10
Speed control, five-step Transformer RTRE 7 RTRE 7
Speed control, five step high/low Transformer REU 7* REU 7*
Speed control, stepless Thyristor – –
Wiring diagram p. 442-461 6 6
* + S-ET 10
Circular duct

54 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 47 60 57 55 52 47 44 38 LwA Inlet 65 44 61 56 58 57 52 49 43
LwA Outlet 68 55 61 59 60 63 58 51 45 LwA Outlet 66 46 56 58 60 61 58 50 39
LwA Surrounding 47 21 36 41 39 42 37 28 23 LwA Surrounding 46 19 36 38 39 39 38 33 26
Measurement point: 0.0428 m³/s @ 208 Pa Measurement point: 0.0456 m³/s @ 222 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 52 62 63 61 58 57 56 53 LwA Inlet 73 46 60 70 65 66 63 58 52
LwA Outlet 75 55 63 69 67 67 69 63 59 LwA Outlet 83 53 62 82 70 70 70 62 56
LwA Surrounding 50 31 39 45 42 40 41 40 39 LwA Surrounding 58 29 40 51 51 53 50 41 33
Measurement point: 0.0761 m³/s @ 275 Pa Measurement point: 0.124 m³/s @ 304 Pa
fans
Circular duct
Circular Duct Fans | 55

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 55 60 64 68 66 65 61 56 LwA Inlet 78 56 73 73 67 67 68 64 57
LwA Outlet 78 57 60 66 74 71 71 64 59 LwA Outlet 86 64 75 84 79 75 72 67 61
LwA Surrounding 59 37 41 48 57 50 48 42 36 LwA Surrounding 63 42 53 59 59 54 50 43 35
Measurement point: 0.229 m³/s @ 441 Pa Measurement point: 0.267 m³/s @ 633 Pa

KVO 355 KVO 400

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 57 73 66 66 69 69 68 63 LwA Inlet 80 61 75 71 69 73 72 70 65
LwA Outlet 83 66 72 71 74 77 75 74 68 LwA Outlet 84 68 73 74 75 78 76 75 69
LwA Surrounding 60 41 55 52 52 53 51 46 41 LwA Surrounding 63 39 56 57 54 57 54 51 45
Measurement point: 0.455 m³/s @ 405 Pa Measurement point: 0.441 m³/s @ 390 Pa
Circular duct

56 | Circular Duct Fans


fans

KD EC NEW! Electrical
accessories
• EC-motors, high level of efficiency
• 100% speed controllable
• Integrated motor protection
• Supplied with mounting bracket
CO2RT
• Potentiometer included for ease of commissioning p. 368

The KD EC series have external rotor motors (EC) with a mixed


flow impeller which reduces the external dimensions of the fans.
These fans have a high capacity in relation to their compact de-
sign. Brackets are supplied with the fans to make installation
easier. The FK mounting clamp facilitates easy installation and CXE p. 369
removal, and prevents the transfer of vibration to the duct. The
fans are delivered with a pre-wired potentiometer(0-10V) that
allows you to easily find the desired working point.

Motor protection is integrated in the electronics of the motor.


MTV p. 359
The casing is manufactured from galvanized sheet steel.

Quick selection
EC-Vent
p. 365
11087,11354,11352,11360,11344,11358

KD EC 315E
KD EC 355E
KD EC 400D MTP p. 359
KD EC 400E
KD EC 450D
KE EC 500D

IR24-P
p. 368

RT p. 377

Technical data
REV p. 380
KD EC 315E 355E 400E 400D 450D 500D
Art. no. 11549 11560 11561 11564 11562 11563
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 400 3~ 400 3~ 400 3~
Power W 428 355 926 1937 1872 1848
Current A 1.98 1.69 4.08 2.99 2.91 2.83
Max. air flow m3/s 0.963 1.05 1.93 2.35 2.57 2.77
R.p.m. min-1 1723 1295 1452 1906 1607 1605
Max. temp. of transported air °C 40 40 40 40 40 40
“ when speed controlled °C 60 60 60 60 60 60
Sound pressure level at 3 m dB(A) 72 53 62 74 69 68
Weight kg 13 14 21.6 22.8 28.6 28.2
Insulation class, motor F F F F F F
Enclosure class, motor 54 54 54 54 54 54
Wiring diagram p. 442-461 60 60 58 59 59 59
fans
Circular duct
Circular Duct Fans | 57

Dimensions Ventilation
accessories

KD EC 315E

FK p. 388

SG p. 389

VK p. 389

RSK p. 388

KD EC 355E/400D/400E/450D/500D

LDC p. 390

FFR p. 391

CB p. 393

KD EC øA øB øC øD øE F øG H I J K L M
315E 315 302 315 355 455 49 10 484 25 53.5 89 534 9
355E 355 - 355 400 503 40 10 516 - 38 97 583 9
400 400 - 400 450 560 44 10 602 - 37 94 639 9
450D 450 - 450 500 663 46 10 686 - 50 121 742 9
500D 500 - 450 500 663 46 10 642 - 50 121 742 9
Circular duct

58 | Circular Duct Fans


fans

Performance

KD EC 315E KD EC 355E

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 57 75 76 76 75 68 62 55 LwA Inlet 77 57 74 70 69 67 62 57 50
LwA Outlet 82 57 78 74 74 74 71 63 56 LwA Outlet 76 56 71 69 69 70 65 60 53
LwA Surrounding 79 44 67 71 74 74 68 62 55 LwA Surrounding 60 24 40 52 55 56 52 45 36
Measurement point: 0.433 m3/s @ 278 Pa Measurement point: 0.523 m3/s @ 204 Pa

KD EC 400E KD EC 400D

73

10V

2,8V

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 63 79 80 80 77 73 67 59 LwA Inlet 92 64 82 86 87 86 81 75 67
LwA Outlet 90 64 84 83 84 84 79 72 60 LwA Outlet 94 69 83 86 90 89 85 78 71
LwA Surrounding 71 28 49 60 69 66 57 51 36 LwA Surrounding 81 33 53 72 77 77 68 60 52
Measurement point: 1.06 m3/s @ 336 Pa Measurement point: 1.29 m3/s @ Pa 578
fans
Circular duct
Circular Duct Fans | 59

KD EC 450D KD EC 500D

10V
10V

5,3V 3,5V

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 89 66 82 82 83 82 78 72 64 LwA Inlet 89 66 82 82 83 80 78 72 64
LwA Outlet 91 63 81 81 87 86 81 75 68 LwA Outlet 92 64 83 82 88 87 81 75 69
LwA Surrounding 76 31 57 70 71 72 66 56 46 LwA Surrounding 75 33 57 68 71 70 65 53 41
Measurement point: 1.16 m3/s @ 509 Pa Measurement point: 1.39 m3/s @ 482 Pa
Circular duct

60 | Circular Duct Fans


fans

KD Electrical
accessories
• High efficiency, low noise
• Speed-controllable
• Integral thermal contacts
• Can be installed in any position
S-ET p. 373
• Maintenance-free and reliable

The KD series have external rotor motors with a mixed flow im-
peller which reduces the external dimensions of the fans. These
fans have high flow capacity in relation to their compact design.
Brackets are supplied with the fans to make installation easier.
The FK mounting clamp facilitates easy installation and removal RTRE p. 356
and prevents the transfer of vibration to the duct.
To protect the motor from overheating KD 200 L1, 250, 315
M1, 315 L1 and 355 S1 have integral thermal contacts with
electrical reset, and the remaining sizes have integral thermal
contacts with leads to a TK triggering device.
The casing is manufactured from galvanized sheet steel. RE p. 356

Quick selection

REU p. 356

1 1 KD 400 M1
2 KD 400 M3
2 3 KD 400 XL1/3, KD 450 M1/3
3 4 KD 450 XL1, KD 500 M1
4 5 KD 450 XL3
5 6 KD 500 M3
6
REE p. 357
7
8

1 2 3 4 5 6 7 8 1 2 3 5 6 REV p. 380
4

Technical data
KD 200 L1** 250 M1** 250 L1** 315 M1** 315 L1** 315 XL1 355 S1** 355 M1 355 XL1 355 XL3
Art. no. 1284 1285 1286 1287 1288 1289 1291 1292 1294 1296
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~
Power W 257 254 369 252 372 276 371 275 431 451
Current A 1.14 1.13 1.60 1.12 1.62 1.29 1.61 1.30 1.90 0.96
Max. air flow m3/s 0.37 0.40 0.55 0.39 0.59 0.77 0.60 0.85 1.10 1.16
R.p.m. min-1 2562 2572 2604 2573 2595 1375 2597 1375 1309 1399
Max. temp. of transported air °C 55 55 70 55 70 70 70 70 70 70
“ when speed controlled °C 46 46 70 46 70 70 70 70 70 70
Sound pressure level at 3 m dB(A) 53 54 55 59 54 52 54 50 56 58
Weight kg 6.8 6.5 9.4 5.5 9 14.2 7.9 14 18.6 16.7
Insulation class, motor F F F F F F F B F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 54 IP 44 IP 54 IP 54 IP 54
Capacitor µF 6 6 10 6 10 6 10 6 10 –
Motor protection Integral Integral Integral Integral Integral S-ET 10 Integral S-ET 10 S-ET 10 STDT 16
Speed control, five-step Transf. RE 1.5 RE 1.5 RE 3 RE 1.5 RE 3 RTRE 3 RE 3 RTRE 1.5 RTRE 3 RTRD 2
Speed control, five step high/low Transf. REU 1.5 REU 1.5 REU 3 REU 1.5 REU 3 REU 1.5* REU 3 REU 1.5* REU 3* RTRDU 2
Speed control, stepless Thyristor REE 2 REE 2 REE 2 REE 2 REE 2 REE 2* REE 2 REE 2* REE 4* –
Wiring diagram p. 442-461 2 2 2 2 2 6 2 6 6 8
*+ S-ET 10
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
fans
Circular duct
Circular Duct Fans | 61

Dimensions Ventilation
accessories
KD 315 XL1/355 M1 KD 355 XL/400 M/400 XL/450 M/450 XL/500 M
ØA ØA

F
L
FK p. 388
ØG(4x)
M M

H
ØG(4x)

SG p. 389
K

K
J
I

65
ØB
ØC ØC
ØD ØD
ØE ØE

VK p. 389
KD 200/250/315 L1 KD 315 M1/355 S1
L

0
25

Ø1
M M
H/2

10
30
RSK p. 388
N/2
N
H

60
N
10 10
LDC p. 390
25

45
ØE 31
J

ØC
65

ØE

KD ⌀A ⌀B ⌀C ⌀D ⌀E F ⌀G H I J K L M N
200 - - 198 - 313 - - 380 - 25 - - 15 180
250 M - - 248 - 313 - - 310 - 25 - - 15 180
FFR p. 391
250 L1 - - 248 - 353 - - 385 - 25 - - 15 205
315 M1 - - - - 313 - - - - - - - 15 180
315 L1 - - 313 - 353 - - 305 - 25 - - 15 205
315 XL1 315 302 315 355 455 49 10 484 25 53.5 89 540 9 -
355 S1 - - - - 353 - - - - - - - 15 205 CB p. 393
355 M1 355 302 315 355 455 35 10 435 25 53.5 89 540 9 -
45

355 XL 355 - 355 400 503 40 10 516 - 38 97 590 9 -


400 M 400 - 355 400 503 40 10 480 - 38 97 590 9 -
400 XL 400 - 400 450 560 44 12 602 - 37 94 662 9 -
450 M 450 - 400 450 560 44 12 559 - 37 94 662 9 -
450 XL 450 - 450 500 660 46 12 686 - 50 121 812 9 -
500 M 500 - 450 500 660 46 12 643 - 50 121 812 9 -

KD 400 M1 400 M3 400 XL1 400 XL3 450 M1 450 M3 450 XL1** 450 XL3 500 M1** 500 M3
Art. no. 1297 1300 1301 1302 1303 1304 19546 1307 19547 1310
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~
Power W 432 456 855 792 857 778 1392 1246 1386 1243
Current A 1.90 0.952 4.24 1.53 4.21 1.53 6.16 2.22 6.12 2.20
Max. air flow m3/s 1.16 1.22 1.62 1.65 1.60 1.64 2.35 2.08 2.37 2.18
R.p.m. min-1 1307 1397 1298 1304 1308 1307 1289 1325 1290 1315
Max. temp. of transported air °C 70 70 65 67 65 70 60 61 62 62
“ when speed controlled °C 70 70 65 67 65 70 60 30 57 51
Sound pressure level at 3 m dB(A) 54 57 64 61 61 63 61 61 64 65
Weight kg 18.3 16.3 26.5 24 26 23.5 37 32.5 37 32
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF 10 – 16 – 16 – 30 – 30 –
Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16
Speed control, five-step Transformer RTRE 3 RTRD 2 RTRE 5 RTRD 2 RTRE 5 RTRD 2 RTRE 7 RTRD 4 RTRE 7 RTRD 4
Speed control, five step high/low Transformer REU 3* RTRDU 2 REU 5* RTRDU 2 REU 5* RTRDU 2 REU 7* RTRDU 4 REU 7* RTRDU 4
Speed control, stepless Thyristor REE 4* – – – REE 2* – - – - –
Wiring diagram p. 442-461 6 8 6 8 6 8 6 8 6 8
*+ S-ET 10
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Circular duct

62 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 60 70 71 75 71 64 64 57 LwA Inlet 79 55 66 69 76 73 66 65 61
LwA Outlet 84 57 71 75 76 77 78 76 73 LwA Outlet 79 55 70 71 73 73 72 65 59
LwA Surrounding 60 27 28 46 55 56 53 48 39 LwA Surrounding 61 22 28 43 56 56 53 50 44
Measurement point: 0.184 m³/s @ 273 Pa Measurement point: 0.217 m³/s @ 272 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 56 73 75 78 75 71 71 65 LwA Inlet 79 54 64 68 76 73 68 66 62
LwA Outlet 82 56 71 71 76 74 76 71 64 LwA Outlet 81 58 70 70 76 75 74 67 60
LwA Surrounding 62 28 37 46 61 50 48 50 38 LwA Surrounding 66 33 33 41 65 50 46 45 40
Measurement point: 0.276 m³/s @ 356 Pa Measurement point: 0.216 m³/s @ 277 Pa
fans
Circular duct
Circular Duct Fans | 63

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 59 69 71 75 75 71 69 67 LwA Inlet 74 60 63 68 69 68 61 56 46
LwA Outlet 81 54 68 70 74 75 76 71 65 LwA Outlet 75 59 69 66 67 69 66 56 48
LwA Surrounding 61 33 36 44 60 50 47 48 40 LwA Surrounding 59 33 42 51 52 55 52 38 27
Measurement point: 0.326 m³/s @ 337 Pa Measurement point: 0.423 m³/s @ 160 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 57 68 69 75 74 72 70 68 LwA Inlet 73 62 65 67 66 65 61 56 46
LwA Outlet 83 58 68 68 76 77 78 72 67 LwA Outlet 75 57 69 66 68 70 65 56 48
LwA Surrounding 61 32 35 43 60 50 49 49 41 LwA Surrounding 57 40 40 48 51 52 49 38 27
Measurement point: 0.329 m³/s @ 337 Pa Measurement point: 0.509 m³/s @ 148 Pa
Circular duct

64 | Circular Duct Fans


fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 55 75 72 69 66 62 61 56 LwA Inlet 79 55 77 73 71 67 63 63 57
LwA Outlet 78 50 74 70 70 68 65 64 59 LwA Outlet 79 50 76 71 72 70 66 66 61
LwA Surrounding 63 26 48 60 59 53 47 47 42 LwA Surrounding 65 29 52 60 60 57 51 51 42
Measurement point: 0.599 m³/s @ 198 Pa Measurement point: 0.635 m³/s @ 226 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 52 73 71 69 64 61 60 54 LwA Inlet 77 52 73 71 69 64 61 60 54
LwA Outlet 77 48 73 70 71 68 65 64 59 LwA Outlet 77 48 73 70 71 68 65 64 59
LwA Surrounding 60 27 45 56 57 51 46 46 39 LwA Surrounding 60 27 45 56 57 51 46 46 39
Measurement point: 0.65 m³/s @ 193 Pa Measurement point: 0.637 m³/s @ 196 Pa
fans
Circular duct
Circular Duct Fans | 65

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 84 55 79 78 77 71 68 66 58 LwA Inlet 83 53 78 77 77 71 68 66 58
LwA Outlet 85 55 79 80 79 75 71 69 61 LwA Outlet 85 55 78 79 79 75 72 70 60
LwA Surrounding 70 21 62 64 68 59 54 52 41 LwA Surrounding 68 18 44 61 65 61 53 51 42
Measurement point: 0.811 m³/s @ 287 Pa Measurement point: 0.825 m³/s @ 282 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 83 57 77 79 77 69 69 65 58 LwA Inlet 83 53 78 78 77 68 68 66 59
LwA Outlet 83 51 75 76 79 75 70 67 61 LwA Outlet 84 52 77 77 80 75 72 69 61
LwA Surrounding 68 25 47 67 61 56 55 51 43 LwA Surrounding 70 15 45 68 66 59 53 50 42
Measurement point: 0.802 m³/s @ 280 Pa Measurement point: 0.822 m³/s @ 282 Pa
Circular duct

66 | Circular Duct Fans


fans

KD 450 XL3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 69 76 75 75 74 73 66 59 LwA Inlet 84 64 76 78 78 77 73 66 60
LwA Outlet 82 69 76 73 76 76 72 67 61 LwA Outlet 86 60 76 78 82 80 75 69 63
LwA Surrounding 68 35 54 60 65 61 59 46 40 LwA Surrounding 68 34 47 60 61 65 60 47 40
Measurement point: 1.18 m³/s @ 372 Pa Measurement point: 1.04 m³/s @ 347 Pa

KD 500 M3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 69 75 76 75 73 72 65 59 LwA Inlet 84 66 77 78 78 75 73 66 59
LwA Outlet 83 70 75 72 77 78 73 67 60 LwA Outlet 86 62 77 77 82 81 75 68 63
LwA Surrounding 71 41 58 63 68 64 60 48 48 LwA Surrounding 71 26 46 63 66 67 63 55 51
Measurement point: 1.18 m³/s @ 378 Pa Measurement point: 0.979 m³/s @ 364 Pa
fans
Circular duct
Circular Duct Fans | 67

Reference: EON Kharadi, Pune, India

Type of Building: SEZ IT Park


Products/Solution: MUB, Inline (K, KD), Axial, Jet Nozzles, Grilles
Circular duct

68 | Circular Duct Fans


fans

KVK Electrical
accessories
• Speed-controllable
• Integral thermal contacts
• Low sound level
• Compact construction
S-ET p. 373
The KVK 125-160 models have a single-inlet centrifugal fan, size
200-500 have double-inlet centrifugal fans. All sizes have forward
curved blades and a maintenance-free external rotor motor.
To protect the motor from overheating the KVK 125-160 has
integral thermal contacts with electrical reset, and size 200-500
has leads for connection to a TK triggering device. RTRE p. 356
The fans can be installed in any position, and are easy to con-
nect to spiral ducts using FK mounting clamps.
The KVK models are manufactured from galvanized sheet steel
and are thermally and acoustically insulated with a 50 mm layer
of rockwool with a surface liner which prevents the migration of
fibres into the airstream. RE p. 356

Quick selection

REU p. 356

733, 2228, 2218, 2229, 5010


6663, 6683, 6687, 3115, 7657

1 KVK 315M
1 KVK 125
2 KVK 315L, 355
2 KVK 160M
3 KVK 400
3 KVK 160L
4 KVK 500
4 KVK 200
5 KVK 250 REE p. 357
2
3

REV p. 380
1 4
1 2 3 4 5

Technical data
KVK 125 160 M 160 L 200 250
Art. no. 2430 2433 2434 1337 1347
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 92.7 111 134 172 308
Current A 0.409 0.48 0.59 0.75 1.34
Max. air flow m3/s 0.106 0.123 0.138 0.197 0.311
R.p.m. min-1 1978 2062 2519 1807 1833
Max. temp. of transported air °C 68 70 70 57 50
“ when speed controlled °C 68 70 70 57 50
Sound pressure level at 3 m dB(A) 38 39 39 40 43
Weight kg 11 11.3 11.8 13.4 16.3
Insulation class, motor B B B B F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF 2 2 4 4 8
Motor protection Integral Integral Integral S-ET 10 S-ET 10
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RTRE 1.5 RTRE 1.5
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5* REU 1.5*
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1* REE 2*
Wiring diagram p. 442-461 2 2 2 5 5
* + S-ET 10
fans
Circular duct
Circular Duct Fans | 69

Dimensions Ventilation
accessories

A
øH

B
FK p. 388
C

D
E

SG p. 389
I

KVK A B C D E F G øH I
125 230 266 151 114 367 415 464 125 40
160 230 266 134 132 367 415 464 160 40
G

VK p. 389
I

IGK p. 388
A
I

øH

RSK p. 388
C

D
E
LDC p. 390
I

KVK A B C D E F G øH I
200 340 345 191 193 395 395 440 200 20
250 380 385 198 228 460 400 490 250 40
315 540 545 328 256 520 570 655 315 40
G

355 540 545 328 256 520 570 655 355 40 FFR p. 391
400 540 545 328 256 520 570 680 400 50
500 750 680 400 355 710 718 850 500 80
I

CB p. 393

KVK 315 M 315 L 355 400 500


Art. no. 1357 1365 1370 1375 4506
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 335 643 614 603 1452
Current A 1.49 2.82 2.69 2.64 6.28
Max. air flow m3/s 0.542 0.789 0.72 0.73 1.49
R.p.m. min-1 1324 1201 1220 1186 1235
Max. temp. of transported air °C 70 53 40 40 68
“ when speed controlled °C 70 53 40 40 68
Sound pressure level at 3 m dB(A) 35 36 36 39 56
Weight kg 30 32.2 32.1 32 66.9
Insulation class, motor B B B B F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF 10 20 20 20 25
Motor protection S-ET 10 S-ET 10 S-ET 10 S-ET 10 S-ET 10
Speed control, five-step Transformer RTRE 3 RTRE 3 RTRE 3 RTRE 3 RTRE 7
Speed control, five step high/low Transformer REU 3* REU 3* REU 3* REU 3* REU 7*
Speed control, stepless Thyristor REE 2* REE 4* REE 4* REE 4* –
Wiring diagram p. 442-461 5 5 5 5 3
* + S-ET 10
Circular duct

70 | Circular Duct Fans


fans

Performance

KVK 125 KVK 160 M

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 57 37 55 50 45 42 41 36 29 LwA Inlet 62 39 61 53 48 44 41 38 35
LwA Outlet 70 50 61 58 60 66 62 55 48 LwA Outlet 72 53 64 64 64 68 65 57 51
LwA Surrounding 45 17 33 40 41 36 36 25 16 LwA Surrounding 46 10 43 38 37 38 27 24 21
Measurement point: 0.0637 m³/s @ 226 Pa Measurement point: 0.0679 m³/s @ 258 Pa

KVK 160 L

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 48 62 53 49 46 45 42 38 LwA Inlet 66 47 63 59 58 55 48 41 35
LwA Outlet 75 56 65 66 67 69 69 62 57 LwA Outlet 73 59 63 66 67 66 66 61 54
LwA Surrounding 46 25 43 39 39 34 30 25 18 LwA Surrounding 47 19 38 43 42 35 31 26 19
Measurement point: 0.0689 m³/s @ 294 Pa Measurement point: 0.0985 m³/s @ 255 Pa
fans
Circular duct
Circular Duct Fans | 71

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 46 65 60 57 48 49 44 37 LwA Inlet 60 56 56 52 42 43 41 39 37
LwA Outlet 76 62 68 68 69 69 69 65 59 LwA Outlet 71 59 63 58 63 66 63 59 57
LwA Surrounding 50 28 45 45 44 39 37 31 22 LwA Surrounding 42 36 36 36 34 31 28 22 18
Measurement point: 0.187 m³/s @ 337 Pa Measurement point: 0.298 m³/s @ 177 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 62 56 52 45 47 44 41 39 LwA Inlet 63 61 55 52 45 47 44 41 39
LwA Outlet 73 60 61 61 64 68 66 63 60 LwA Outlet 73 59 61 61 64 68 67 64 60
LwA Surrounding 43 32 36 37 37 35 34 30 26 LwA Surrounding 44 32 36 37 37 35 34 30 26
Measurement point: 0.394 m³/s @ 305 Pa Measurement point: 0.432 m³/s @ 296 Pa
Circular duct

72 | Circular Duct Fans


fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 64 60 58 55 52 51 48 48 46 LwA Inlet 71 53 68 66 54 53 53 58 57
LwA Outlet 74 62 62 64 65 69 67 65 60 LwA Outlet 78 64 68 68 69 70 69 72 66
LwA Surrounding 47 34 37 39 42 38 37 38 27 LwA Surrounding 63 31 59 59 48 44 38 41 41
Measurement point: 0.438 m³/s @ 286 Pa Measurement point: 0.82 m³/s @ 405 Pa
fans
Circular duct
Circular Duct Fans | 73

Reference: Hotel “Ukraine”, Moscow, Russia

Type of Building: The hotel “Ukraine” is not only one of the best hotels but also an
integral part of the architectural and historical view in Moscow.
Products/Solution:
98 Modular air handling units, type DV, including 15 DV Coolers
81 Duct and roof fans; K, KD, KT, RSI, DVSI
4 Compact heat recovery units; Topvex
4 Compact supply units; TLP
2 Residential heat recovery units; VR
Circular duct

74 | Circular Duct Fans


fans

KVK DUO Electrical


accessories
• Speed controllable
• Integral thermal contacts
• Low sound level
• Twin fan
S-ET p. 373
KVK DUO models are designed for applications where a standby
fan is required.
The fans have double inlet centrifugal fans with forward
curved impellers and maintenance-free external rotor motors. To
protect the motors from overheating the fans have integral ther-
AWE-SK
mal contacts with leads for connection to a TK triggering device. p. 372
The fans are easy to connect to spiral ducts using FK mounting
clamps. The KVK DUO models are manufactured from galvanized
sheet steel and are thermally and acoustically insulated with a
50 mm layer of mineral wool. Internal surfaces are protected
with perforated galvanized sheet steel.
RTRE p. 356

Quick selection

REU p. 356
719, 3647, 3115, 1758

733, 2228, 2218, 2229


1 KVK DUO 315M
1 KVK DUO 125
2 2 KVK DUO 315L, 355
2 KVK DUO 160 3
3 KVK DUO 200 3 KVK DUO 400
4 KVK DUO 250

REE p. 357

Auto changeover
panel on request

1 2 3 4 1

Technical data
KVK DUO 125 160 200 250 315M 315L
Art. no. 5341 5127 5030 5031 5032 5773
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 41.4 69.1 172 304 335 643
Current A 0.171 0.301 0.75 1.31 1.49 2.82
Max. air flow m /s 0.0528
3
0.105 0.197 0.316 0.542 0.789
R.p.m. min-1 1724 1943 1807 1962 1324 1201
Max. temp. of transported air °C 65 55 56 50 69 53
“ when speed controlled °C 65 55 56 55 69 53
Sound pressure level at 3 m dB(A) 29 37 40 42 35 36
Weight kg 17.8 19 28 41 66 68.5
Insulation class, motor B F B F B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 54 IP 54
Capacitor µF 1.5 2 4 8 10 20
Motor protection AWE-SK AWE-SK S-ET 10 S-ET 10 S-ET 10 S-ET 10
Speed control, five-step Transformer RTRE 1.5 RTRE 1.5 RTRE 1.5 RTRE 1.5 RTRE 3 RTRE 3
Speed control, five step high/low Transformer REU 1.5** REU 1.5** REU 1.5* REU 1.5* REU 3* REU 3*
Speed control, stepless Thyristor REE 1** REE 1** REE 1* REE 2* REE 2** REE 4*
Wiring diagram p. 442-461 5 5 5 5 5 5
*+ S-ET 10; ** + AWE-SK
fans
Circular duct
Circular Duct Fans | 75

Dimensions Ventilation
accessories

B
FK p. 388

øH
A
C

D
E SG p. 389
F
G

VK p. 389

RSK p. 388
KVK DUO A B C D E F G øH
125 333 275 165 255 510 350 425 125
160 333 275 165 255 510 350 425 160
200 386 325 190 300 600 400 475 200
250 460 400 207 360 720 500 615 250 LDC p. 390
315M 505 450 250 473 946 565 680 315
315L 505 450 250 473 946 565 680 315
355 505 450 250 473 946 565 680 355
400 505 450 250 473 946 565 680 400

FGR p. 392

CB p. 393

KVK DUO 355 400


Art. no. 5774 5775
Voltage/Frequency V/50 Hz 230 1~ 230 1~
Power W 614 603
Current A 2.69 2.64
Max. air flow m3/s 0.72 0.73
R.p.m. min-1 1220 1186
Max. temp. of transported air °C 40 40
“ when speed controlled °C 40 40
Sound pressure level at 3 m dB(A) 36 39
Weight kg 67 72
Insulation class, motor B B
Enclosure class, motor IP 54 IP 54
Capacitor µF 20 20
Motor protection S-ET 10 S-ET 10
Speed control, five-step Transformer RTRE 3 RTRE 3
Speed control, five step high/low Transformer REU 3* REU 3*
Speed control, stepless Thyristor REE 4* REE 4*
Wiring diagram p. 442-461 5 5
* + S-ET 10
Circular duct

76 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 52 47 48 41 40 38 33 27 24 LwA Inlet 59 40 55 55 52 46 39 33 26
LwA Outlet 61 51 54 54 54 53 53 47 40 LwA Outlet 68 50 57 62 64 61 59 54 49
LwA Surrounding 35 28 32 25 25 26 17 20 19 LwA Surrounding 44 7 32 41 40 30 22 20 12
Measurement point: 0.0317 m³/s @ 103 Pa Measurement point: 0.0629 m³/s @ 142 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 66 47 63 59 58 55 48 41 35 LwA Inlet 69 50 67 62 59 54 50 47 41
LwA Outlet 73 59 63 66 67 66 66 61 54 LwA Outlet 77 62 68 67 69 69 71 67 62
LwA Surrounding 47 19 38 43 42 35 31 26 19 LwA Surrounding 49 22 42 45 45 37 32 27 24
Measurement point: 0.0985 m³/s @ 255 Pa Measurement point: 0.142 m³/s @ 347 Pa
fans
Circular duct
Circular Duct Fans | 77

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 60 56 56 52 42 43 41 39 37 LwA Inlet 63 62 56 52 45 47 44 41 39
LwA Outlet 71 59 63 58 63 66 63 59 57 LwA Outlet 73 60 61 61 64 68 66 63 60
LwA Surrounding 42 36 36 36 34 31 28 22 18 LwA Surrounding 43 32 36 37 37 35 34 30 26
Measurement point: 0.298 m³/s @ 177 Pa Measurement point: 0.394 m³/s @ 305 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 61 55 52 45 47 44 41 39 LwA Inlet 64 60 58 55 52 51 48 48 46
LwA Outlet 73 59 61 61 64 68 67 64 60 LwA Outlet 74 62 62 64 65 69 67 65 60
LwA Surrounding 44 32 36 37 37 35 34 30 26 LwA Surrounding 47 34 37 39 42 38 37 38 27
Measurement point: 0.432 m³/s @ 296 Pa Measurement point: 0.438 m³/s @ 286 Pa
Circular duct

78 | Circular Duct Fans


fans

KVKE EC Electrical
accessories
• EC-motors, high level of efficiency
• 100% speed controllable
• Low sound level
• Integrated motor protection MTP 10
• Potentiometer included for ease of commissioning p. 359

The KVKE EC models have a single inlet centrifugal fan with back-
ward curved blades and a maintenance-free external rotor motor
(EC). These fans develop relatively high static pressure and have a
very high efficiency. The fans are delivered with a pre-wired poten- EC-Vent
tiometer (0-10V) that allows you to easily find the desired working p. 365
point.
The KVKE motor and impeller are mounted on the access cover for
ease of maintenance. The service cover can be easily removed by
withdrawing the hinge pin. To protect the motor from overheating,
the fans have integral thermal contacts with automatic reset. The MTV 1/010
fans can be installed in any position and are easy to connect to spiral p. 359
ducts using FK mounting clamps. The KVKE models are manufac-
tured from galvanized sheet steel and are thermally and acoustically
insulated with a 50 mm layer of rockwool with a surface liner which
prevents the migration of fibres into the airstream.

Quick selection REV p. 380


8166, 7721, 7755, 7788, 8159

1 KVKE 125 EC
2 KVKE 160 EC
3 KVKE 200 EC
4 KVKE 250 EC
5 KVKE 315 EC

1 2 3 4 5

Technical data
KVKE EC 125 160 200 250 315
Art. no. 2570 2571 2575 2577 2578
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 68.7 67.7 156 265 308
Current A 0.536 0.531 1.10 1.64 1.89
Max. air flow m3/s 0.104 0.151 0.24 0.321 0.492
R.p.m. min-1 3339 2592 3033 2821 2215
Max. temp. of transported air °C 60 60 60 55 45
“ when speed controlled °C 60 60 60 55 45
Sound pressure level at 3 m dB(A) 41 39 46 49 47
Weight kg 13.2 17 18.8 28.1 38.8
Insulation class, motor B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection Integral Integral Integral Integral Integral
Speed control Electronic MTP MTP MTP MTP MTP
Wiring diagram p. 442-461 42 42 42 42 42
fans
Circular duct
Circular Duct Fans | 79

Dimensions Ventilation
accessories
H

50

*
FK p. 388

C
B
G

SG p. 389
E

47
F
27
øA

VK p. 389

KVKE EC ⌀A B C D E F G H
125 125 433 479 125 128,5 442 246 470
160 160 482 528 145.5 132.5 505 266 530
200 200 482 534 150.5 149 505 303 530
IGK p. 388
250 250 578 700 176 174 596 359 620
315 315 680 802 208.5 207.5 705.5 430 730

RSK p. 388

LDC p. 390

FFR p. 391

CB p. 393
Circular duct

80 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 60 46 57 56 50 45 40 37 35 LwA Inlet 57 43 54 50 48 44 45 38 32
LwA Outlet 76 54 63 69 71 69 66 60 46 LwA Outlet 72 52 60 63 68 66 61 54 41
LwA Surrounding 48 18 40 41 43 41 38 35 32 LwA Surrounding 46 20 40 37 40 34 38 35 27
Measurement point: 0.057 m³/s @ 410 Pa Measurement point: 0.0831 m³/s @ 329 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 64 52 59 60 56 53 50 47 45 LwA Inlet 67 53 64 60 59 54 48 46 40
LwA Outlet 80 57 64 72 76 74 71 64 53 LwA Outlet 83 64 70 72 80 76 75 66 56
LwA Surrounding 53 27 43 49 49 40 39 39 35 LwA Surrounding 56 32 49 50 53 42 39 35 26
Measurement point: 0.144 m³/s @ 468 Pa Measurement point: 0.176 m³/s @ 709 Pa
fans
Circular duct
Circular Duct Fans | 81

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 53 64 61 51 49 45 41 36
LwA Outlet 85 63 71 84 75 72 67 62 54
LwA Surrounding 54 37 48 52 44 40 36 32 26
Measurement point: 0.295 m³/s @ 520 Pa
Circular duct

82 | Circular Duct Fans


fans

KVKE Electrical
accessories
• Speed controllable
• Integral thermal contacts
• Low sound level
• Servicing cover
RE p. 356
The KVKE models have a single inlet centrifugal fan with backward
curved blades and a maintenance-free external rotor motor. These
fans develop relatively high static pressure and have a high efficien-
cy.
The KVKE motor and impeller are mounted on the access cover for
ease of maintenance. The service cover can be easily removed by REU p. 356
withdrawing the hinge pin. To protect the motor from overheating,
the fans have integral thermal contacts with automatic reset. The
fans can be installed in any position and are easy to connect to spiral
ducts using FK mounting clamps.
The KVKE models are manufactured from galvanized sheet steel
REE p. 357
and are thermally and acoustically insulated with a 50 mm layer of
rockwool with a surface liner which prevents the migration of fibres
into the airstream.

Quick selection
3680, 662, 3877

3889, 1783, 1777, 1652


1 KVKE 125
2 KVKE 160
1 KVKE 250M
3 KVKE 200 2 KVKE 250L
3 KVKE 315M
4 KVKE 315L

1 2 3 4
1 2 3

Technical data
KVKE 125 160 200 250 M
Art. no. 1406 1409 19522 19524
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~
Power W 55.1 97.6 135 179
Current A 0.244 0.422 0.591 0.796
Max. air flow m /s 0.0854 3
0.148 0.218 0.289
R.p.m. min-1 2548 2687 2633 2612
Max. temp. of transported air °C 70 70 70 70
“ when speed controlled °C 70 70 70 70
Sound pressure level at 3 m dB(A) 34 36 40 43
Weight kg 13.6 17.2 18.8 25.4
Insulation class, motor B B F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44
Capacitor µF 2 3 3.5 5
Motor protection Integral Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5
Speed control, five step high/low Transformer REU 1,5 REU 1.5 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1
Wiring diagram p. 442-461 4 4 4 4
fans
Circular duct
Circular Duct Fans | 83

Dimensions Ventilation
accessories

Free area
H

50
FK p. 388
G

SG p. 389

C
B
E

D
F

60
VK p. 389
øA

KVKE ⌀A B C D E F G H
125 125 433 479 125 128.5 442 246 470
160 160 482 528 145.5 132.5 505 266 530
200 200 482 534 150.5 149 505 303 530 IGK p. 388
250 250 578 700 176 174 596 359 620

RSK p. 388

LDC p. 390

FFR p. 391

CB p. 393

KVKE 250 L* 315 M* 315 L*


Art. no. 19523 19526 19525
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~
Power W 258 285 493
Current A 1.1 1.23 2.14
Max. air flow m /s 0.317
3
0.44 0.608
R.p.m. min-1 2578 2505 2371
Max. temp. of transported air °C 60 60 59
“ when speed controlled °C 60 60 49
Sound pressure level at 3 m dB(A) 44.7 40.5 50
Weight kg 26.9 39.1 40.4
Insulation class, motor F F F
Enclosure class, motor IP 44 IP 44 IP 44
Capacitor µF 7 7 12
Motor protection Integral Integral Integral
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 3
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 3
Speed control, stepless Thyristor REE 2 REE 2 REE 4
Wiring diagram p. 442-461 4 4 4
* Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Circular duct

84 | Circular Duct Fans


fans

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 56 35 50 55 42 40 32 21 17 LwA Inlet 57 55 48 49 48 44 38 35 38
LwA Outlet 70 50 59 67 63 63 61 56 36 LwA Outlet 71 53 58 62 68 65 61 54 40
LwA Surrounding 41 6 35 38 31 32 29 20 15 LwA Surrounding 43 32 30 33 37 35 33 34 35
Measurement point: 0.047 m³/s @ 257 Pa Measurement point: 0.0813 m³/s @ 339 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 61 54 53 58 53 48 46 42 39 LwA Inlet 62 47 55 60 49 47 46 44 38
LwA Outlet 76 54 61 73 69 66 65 57 50 LwA Outlet 77 56 62 72 71 68 67 58 52
LwA Surrounding 47 30 37 41 41 41 37 34 30 LwA Surrounding 50 25 37 49 40 35 33 33 22
Measurement point: 0.12 m³/s @ 380 Pa Measurement point: 0.159 m³/s @ 437 Pa
fans
Circular duct
Circular Duct Fans | 85

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 65 51 60 61 56 52 45 45 41 LwA Inlet 61 46 57 55 52 52 46 47 45
LwA Outlet 78 60 62 69 75 71 70 62 54 LwA Outlet 76 60 59 65 73 68 66 60 55
LwA Surrounding 52 28 44 49 46 36 28 31 23 LwA Surrounding 47 21 38 43 43 36 29 28 26
Measurement point: 0.174 m³/s @ 551 Pa Measurement point: 0.22 m³/s @ 517 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 58 66 66 54 55 45 43 39
LwA Outlet 85 62 71 83 76 74 66 60 53
LwA Surrounding 57 37 48 56 46 40 36 35 29
Measurement point: 0.304 m³/s @ 600 Pa
Rectangular

86 | Rectangular & Square Duct Fans


fans

Rectangular and Square Duct Fans


IE2
2009/640/EG
120°C

3
6
3

10
1
2

5
3

3 7
4 9
3

General
Systemair rectangular and square duct Systemair range plug. The motor and impeller can easily be
fans have been developed for use in Systemair rectangular duct fans are removed from the unit for cleaning and
compact exhaust and supply air systems. available in 3 different versions. Where high servicing.
Covering a wide performance spectrum and pressure losses occur in a system we offer
availability of a comprehensive range of the KE/KT range. The RS and RSI Range Motors
accessories, including heating and cooling is ideal for installing where the ease of All Systemair rectangular duct fans have
coils, filters, silencers and more, offers maintenance or comfort is a requirement. external rotor motors which are suitable
solutions for complete systems for almost The RSI Range is perfectly suited where low to control by means of voltage control.
all applications. Our experience over the noise levels are a pre-requisite. The casings All motors have thermal motor protection
past 35 years and continuous research are manufactured from galvanized steel. embedded in the windings.
and development of new products and Systemair Multiboxes, MUB, are offered The MUB range of square duct fans is
technology have made the Systemair duct in four box sizes with varying capacities equipped with powerful external rotor
fan a market leader. available within one size. The casing motors up to size 499 and from size 500
For instance, the flexibility offered by consists of a self supporting aluminium with IEC standard motors. All MUB/T
removable panels allows the MUB range to profiled frame, with PA6 plastic corner versions are equipped with motors
be adapted to all installation positions and pieces. The MUB/T Multibox has the separated from the airstream.
airflow directions, which can still be decided motor out of the airstream which enables By combining a Systemair TK triggering
during installation. The MUB range is suited temperatures of up to 120°C to be device optimum operational reliability is
for outdoor applications (complete with exhausted. The bottom panel serves as guaranteed.
Systemair weather protection accessories). a drain pan and is complete with a drain
Rectangular & Square Duct Fans | 87

duct fans
Rectangular
1 SRK Damper 6 RSI Rectangular duct fan, 10 PGK Cold water coil
insulated
2 FFK Filter cassette 11 FGV Flexible connection
7 LDR Silencer
3 DS Flexible connections 12 WSG Weather protection guard
8 RB/RBM Heating coil
4 KE/KT Rectangular duct fan 13 UGS Flexible connection
9 VBR Water-heating coil
5 RS Rectangular duct fan 14 SRKG Damper

15 MUB Multibox
14 16 WSD Weather roof
13 16

12

11
14

15 13

11

KE 88 RSI EC NEW!
108 MUB IE2
132
2009/640/EG

Rectangular duct fan Rectangular duct fan Square duct fan, Multibox

KT 92 RSI 112 KDRE/KDRD 144

Rectangular duct fan Rectangular duct fan, Square duct fan,


insulated mixed flow impeller

RS EC NEW!
98 KPB IE2
118 MUB/T EC NEW!
148
2009/640/EG
120°C

Rectangular duct fan KPB; box fan belt driven Square duct fan, with EC-motor,
for higher temp. of transp. air

RS 102 MUB EC 124 MUB/T 152


IE2
2009/640/EG
120°C

Rectangular duct fan, Square duct fan, Square duct fan, Multibox for
insulated Multibox with EC-motor higher temp. of transp. air
88 | Rectangular & Square Duct Fans

KE Electrical
accessories
Rectangular

• Swing-out
duct fans

• Speed-controllable
• Integral thermal contacts
• Can be installed in any position
S-ET p. 373
• Maintenance-free and reliable

The KE models have impellers with forward curved blades and


external rotor motors. The motor and impeller are mounted on the
access cover to facilitate easy maintenance. The casing is manu-
factured from galvanized sheet steel.
To protect the motor from overheating the fans have integral RTRE p. 356
thermal contacts with external leads for connection to a TK trigger-
ing device.
The fans can be installed in any position and are simple to cou-
ple using DS flexible connections. The KE fans have a pre-wired,
integral terminal box.
RE p. 356

Quick selection

8963, 1797, 1659


3404, 501, 504, 1795

1 KE 40-20-4 KE 60-30-4
1
REU p. 356
2 KE 50-25-4 2 KE 60-30-6
3 KE 50-30-4 3 KE 60-35-6
4 KE 50-30-6

REE p. 357

2 3 1
1 4 2 3

REV p. 380

Technical data
KE 40-20-4 KE 50-25-4 KE 50-30-4 KE 50-30-6** KE 60-30-4 KE 60-30-6** KE 60-35-6
Art. no. 1463 1467 19549 19550 1478 19551 1480
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 248 533 700 294 1261 493 554
Current A 1.08 2.51 3.4 1.48 5.93 2.30 2.63
Max. air flow m3/s 0.293 0.479 0.52 0.404 0.847 0.659 0.68
R.p.m. min-1 1059 1298 1009 676 1046 898 565
Max. temp. of transported air °C 45 70 40 70 43 70 41
“ when speed controlled °C 45 69 40 70 43 70 41
Sound pressure level at 3 m dB(A) 55 55 57 49 58 55 51
Weight kg 12.6 18.8 22.7 20.8 30.6 30.3 31
Insulation class, motor F F F F F F F
Enclosure class, motor IP 44 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF 6 8 10 6 20 14 8
Motor protection S-ET 10 S-ET 10 S-ET 10 S-ET 10 S-ET 10 S-ET 10 S-ET 10
Speed control, five-step Transformer RTRE 1,5 RTRE 3 RTRE 5 RTRE 3 RTRE 7 RTRE 3 RTRE 3
Speed control, five step high/low Transformer REU 1,5 REU 3 REU 5 REU 3 REU 7 REU 3 REU 3
Speed control, stepless Thyristor REE 2 * REE 4 REE 4 REE 2 – REE 4 REE 4
Wiring diagram p. 442-461 5 6 6 6 6 6 6
* + S-ET 10
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Rectangular & Square Duct Fans | 89

Dimensions Ventilation
accessories

duct fans
Rectangular
E
D 8,0

H
A

I
DS p. 399
C
B
F

ø10,0(x8)

KE A B C D E F G H I*
VK p. 412
40-20-4 398 198 220 420 440 240 502 32 530
50-25-4 498 248 270 520 540 290 532 34 610
50-30-4/6 498 298 320 520 540 340 562 34 695
G

LDR p. 400
60-30-4/6 598 298 320 620 640 340 642 47 715
60-35-6 598 348 370 620 640 390 717 50 805
* Dimension with fully open hatch.

FFK p. 401

RB p. 402

VBR p. 406
90 | Rectangular & Square Duct Fans

Performance
Rectangular
duct fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 54 66 63 62 57 57 55 50 LwA Inlet 73 62 69 66 59 63 64 62 59
LwA Outlet 72 55 63 66 65 66 63 61 55 LwA Outlet 77 56 64 66 68 73 70 68 64
LwA Surrounding 62 42 49 58 55 56 49 46 42 LwA Surrounding 62 35 50 56 58 55 51 46 51
With LDR 40-20 With LDR 50-25
LwA Inlet 63 54 61 53 46 34 40 43 39 LwA Inlet 59 55 53 51 40 41 43 46 42
LwA Outlet 62 55 58 57 50 43 47 49 44 LwA Outlet 77 77 46 49 41 43 53 55 56
Measurement point: 0.176 m³/s @ 208 Pa Measurement point: 0.24 m³/s @ 273 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 65 69 65 61 67 67 66 60 LwA Inlet 67 58 61 57 56 59 59 56 49
LwA Outlet 78 57 68 66 69 73 71 71 63 LwA Outlet 70 55 58 57 64 65 63 61 53
LwA Surrounding 64 53 57 59 52 56 54 50 43 LwA Surrounding 56 50 48 50 45 49 43 39 35
With LDR 50-30
With LDR 50-30
LwA Inlet 77 77 48 49 46 37 56 56 57
LwA Inlet 59 58 53 42 36 28 42 42 38
LwA Outlet 66 60 60 52 51 45 56 58 55
LwA Outlet 57 55 50 42 44 34 45 47 42
Measurement point: 0.338 m³/s @ 351 Pa
Measurement point: 0.262 m³/s @ 145 Pa
Rectangular & Square Duct Fans | 91

duct fans
Rectangular
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 63 73 66 65 70 69 68 63 LwA Inlet 71 64 66 63 60 62 63 59 53
LwA Outlet 82 63 71 68 74 77 74 75 69 LwA Outlet 75 55 65 62 69 70 67 65 57
LwA Surrounding 65 46 60 55 55 59 56 55 49 LwA Surrounding 62 56 51 58 50 51 49 44 38
With LDR 60-30 With LDR 60-30
LwA Inlet 68 63 65 51 45 39 52 54 52 LwA Inlet 65 64 57 48 40 31 45 45 42
LwA Outlet 68 63 63 53 54 46 57 61 58 LwA Outlet 61 55 57 47 49 38 50 51 46
Measurement point: 0.468 m³/s @ 454 Pa Measurement point: 0.362 m³/s @ 177 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 59 62 58 59 61 61 59 53
LwA Outlet 74 56 62 63 69 67 66 66 58
LwA Surrounding 59 52 51 52 51 52 48 47 40
With LDR 60-35
LwA Inlet 61 60 53 44 40 41 46 48 43
LwA Outlet 61 56 53 48 49 47 51 54 48
Measurement point: 0.439 m³/s @ 235 Pa
92 | Rectangular & Square Duct Fans

KT Electrical
accessories
Rectangular

• Swing-out
duct fans

• Speed-controllable
• Integral thermal contacts
• Can be installed in any position STDT p. 373
• Maintenance-free and reliable

The KT models have impellers with forward curved blades and exter-
nal rotor motors. The motor and impeller are mounted on the access
cover to facilitate easy maintenance. The casing is manufactured
from galvanized steel. RTRD p. 357
To protect the motor from overheating the fans have integral ther-
mal contacts with external leads for connection to a TK triggering
device. The fans can be installed in any position and are simple to
couple using DS flexible connections. The KT fans have a pre-wired,
integral terminal box.
RTRDU
p. 357

Quick selection

REV p. 380

479, 471, 515, 525, 516, 494, 520, 511


493, 502, 533, 463, 483, 465, 478, 468, 466

7 1 KT 40-20-4 1 KT 70-40-4
2 KT 50-25-4 2 KT 70-40-6
3 KT 50-25-6 3 KT 70-40-8
4 KT 50-30-4 4 4 KT 80-50-4
5 KT 60-30-4 5 KT 80-50-6
5
6 KT 60-30-6 6 KT 80-50-8
4 1
7 KT 60-35-4
7 KT 100-50-6
8 KT 60-35-6
8 KT 100-50-8
2 7

1
5
8
2
3 8
6
6 3

Technical data
KT 40-20-4 50-25-4 50-25-6 50-30-4 60-30-4 60-30-6 60-35-4 60-35-6
Art. no. 1482 1487 1485 1489 1494 1493 1499 1497
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 289 565 220 935 1362 418 2478 935
Current A 0.519 0.969 0.44 1.64 2.36 0.855 4.15 1.84
Max. air flow m3/s 0.368 0.544 0.381 0.72 0.953 0.598 1.32 1.08
R.p.m. min-1 1303 1287 826 1223 1279 837 1244 777
Min. static back pressure Pa 0 0 0 0 0 25 170 0
Max. temp. of transported air °C 63.4 66.3 70 41 62.5 39.9 42.3 44.3
“ when speed controlled °C 63.4 51.3 70 41 62.5 39.9 42.3 44.3
Sound pressure level at 3 m dB(A) 52 55 44 57 58 48 61 52.5
Weight kg 12.4 17.4 16.5 20.8 30.4 24.1 36.8 31.2
Insulation class, motor B F F F F F F F
Enclosure class, motor IP 44 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Motor protection STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16
Speed control, five-step Transformer RTRD 2 RTRD 2 RTRD 2 RTRD 2 RTRD 4 RTRD 2 RTRD 7 RTRD 2
Speed control, five step high/low Transformer RTRDU 2 RTRDU 2 RTRDU 2 RTRDU 2 RTRDU 4 RTRDU 2 RTRDU 7 RTRDU 2
Wiring diagram p. 442-461 7 8 8 8 8 8 8 8
Rectangular & Square Duct Fans | 93

Dimensions Ventilation
E accessories

duct fans
Rectangular
D 8,0

H
A

I
DS p. 399
C
B
F

ø10,0(x8)
KT A B C D E F G H I*
VK p. 412
40-20-4 398 198 220 420 440 240 502 32 530
50-25-4/6 498 248 270 520 540 290 532 68 610
50-30-4 498 298 320 520 540 340 562 68 695
60-30-4/6 598 298 320 620 640 340 642 89 715
G

60-35-4/6 598 348 370 620 640 390 717 92 805


LDR p. 400
70-40-4 698 398 420 720 740 440 787 92 900
70-40-6/8 698 398 420 720 740 440 787 92 900
80-50-4/6/8 798 497 520 820 840 540 880 113 1090
100-50-6/8 998 497 520 1020 1040 540 980 113 1140
* Dimension with fully open hatch FFK p. 401

RB p. 402

VBR p. 406

KT 70-40-4 70-40-6 70-40-8 80-50-4 80-50-6 80-50-8 100-50-6 100-50-8


Art. no. 1506 1504 1502 1513 1511 1509 1516 1514
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 4186 1628 951 5639 2799 1167 4450 2287
Current A 7.15 3.02 1.89 9.22 5.12 2.44 7.82 4.68
Max. air flow m3/s 1.84 1.46 1.28 2.15 2.16 1.52 2.73 2.30
R.p.m. min-1 1250 805 661 1266 828 548 794 614
Max. temp. of transported air °C 48.5 60.8 68.7 41 70 62 43 70
Min. static back pressure Pa 0 0 0 510 20 0 105 0
“ when speed controlled °C 48.5 60.8 68.7 41 70 62 43 70
Sound pressure level at 3 m dB(A) 66 57 51 67 59 59 62 58
Weight kg 53 42.4 44.2 71 64 57 80 79
Insulation class, motor F F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Motor protection STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16 STDT 16
Speed control, five-step Transformer RTRD 14 RTRD 4 RTRD 4 RTRD 14 RTRD 7 RTRD 4 RTRD 14 RTRD 7
Speed control, five step high/low Transformer – RTRDU 4 RTRDU 4 – RTRDU 7 RTRDU 4 – RTRDU 7
Wiring diagram p. 442-461 8 8 8 8 8 8 8 8
94 | Rectangular & Square Duct Fans

Performance
Rectangular
duct fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 57 68 64 61 57 56 54 48 LwA Inlet 72 61 67 64 60 64 64 62 58
LwA Outlet 73 54 64 68 65 66 63 60 54 LwA Outlet 76 57 63 64 68 72 69 67 65
LwA Surrounding 60 35 47 58 52 50 45 41 36 LwA Surrounding 62 39 50 53 54 56 52 50 55
With LDR 40-20 With LDR 50-25
LwA Inlet 64 56 62 54 44 33 39 41 36 LwA Inlet 58 53 53 52 38 40 42 44 41
LwA Outlet 62 53 58 58 48 42 46 47 43 LwA Outlet 61 56 53 49 42 46 49 52 53
Measurement point: 0.166 m³/s @ 230 Pa Measurement point: 0.245 m³/s @ 298 Pa

Min. static back pressure: 110 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 52 59 55 52 54 53 50 44 LwA Inlet 75 66 70 64 63 67 67 66 62
LwA Outlet 66 50 55 56 61 59 58 55 48 LwA Outlet 79 62 68 67 70 74 72 71 66
LwA Surrounding 51 33 41 46 45 44 37 33 30 LwA Surrounding 64 45 55 59 55 58 54 49 48
With LDR 50-25 With LDR 50-30
LwA Inlet 54 52 49 40 27 28 33 35 32 LwA Inlet 68 66 62 49 43 36 50 52 51
LwA Outlet 52 50 45 40 35 34 37 39 36 LwA Outlet 66 62 60 52 50 43 55 57 55
Measurement point: 0.19 m³/s @ 132 Pa Measurement point: 0.288 m³/s @ 353 Pa
Rectangular & Square Duct Fans | 95

duct fans
Rectangular
Min. static back pressure: 75 Pa
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 71 71 67 66 71 71 68 64 LwA Inlet 66 59 60 55 55 58 56 54 47
LwA Outlet 81 59 70 68 73 76 73 73 68 LwA Outlet 69 53 62 58 62 62 60 59 52
LwA Surrounding 66 39 59 60 59 57 54 52 48 LwA Surrounding 55 35 49 51 48 46 42 40 35
With LDR 60-30 With LDR 60-30
LwA Inlet 72 71 63 52 46 40 54 53 52 LwA Inlet 60 59 52 40 35 27 39 40 36
LwA Outlet 67 59 62 53 53 45 56 59 57 LwA Outlet 57 53 54 43 42 31 43 45 40
Measurement point: 0.429 m³/s @ 434 Pa Measurement point: 0.261 m³/s @ 218 Pa

Min. static back pressure: 180 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 72 75 67 68 73 72 69 65 LwA Inlet 71 65 65 58 60 62 61 58 55
LwA Outlet 84 67 73 72 76 80 77 75 70 LwA Outlet 74 59 63 63 68 68 66 65 58
LwA Surrounding 68 52 62 63 59 60 55 52 48 LwA Surrounding 60 41 52 56 53 50 47 46 42
With LDR 60-35 With LDR 60-35
LwA Inlet 74 72 68 54 51 55 59 59 57 LwA Inlet 66 65 58 44 43 43 47 48 46
LwA Outlet 73 67 66 59 59 61 64 65 62 LwA Outlet 63 58 56 49 51 49 52 54 50
Measurement point: 0.461 m³/s @ 634 Pa Measurement point: 0.484 m³/s @ 274 Pa
96 | Rectangular & Square Duct Fans
Rectangular
duct fans

Min. static back pressure: 300 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 84 80 77 70 70 76 75 71 69 LwA Inlet 73 67 65 61 63 66 64 62 56
LwA Outlet 87 73 75 75 79 82 80 77 73 LwA Outlet 77 65 66 66 71 71 69 68 61
LwA Surrounding 74 55 64 67 66 68 64 64 60 LwA Surrounding 65 46 57 58 61 55 50 47 42
With LDR 70-40 With LDR 70-40
LwA Inlet 81 80 70 59 55 62 64 63 62 LwA Inlet 68 67 57 49 49 51 53 53 49
LwA Outlet 78 73 68 64 65 67 69 69 66 LwA Outlet 68 65 59 55 57 56 58 59 54
Measurement point: 0.737 m³/s @ 816 Pa Measurement point: 0.586 m³/s @ 392 Pa

Min. static back pressure: 720 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 62 61 59 60 61 61 59 52 LwA Inlet 82 71 74 75 71 76 75 71 67
LwA Outlet 74 56 60 64 69 67 65 64 56 LwA Outlet 90 72 77 77 82 86 84 81 76
LwA Surrounding 58 36 50 52 53 51 46 42 37 LwA Surrounding 75 61 68 67 66 69 64 60 58
With LDR 70-40 With LDR 80-50
LwA Inlet 63 62 53 48 45 47 50 51 46 LwA Inlet 76 71 68 66 61 65 67 65 64
LwA Outlet 63 56 52 52 54 52 55 56 50 LwA Outlet 82 72 71 69 72 75 76 74 73
Measurement point: 0.512 m³/s @ 203 Pa Measurement point: 1.08 m³/s @ 1045 Pa
Rectangular & Square Duct Fans | 97

duct fans
Rectangular
Min. static back pressure: 70 Pa
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 64 67 65 69 72 71 67 62 LwA Inlet 69 59 59 59 59 62 62 58 50
LwA Outlet 82 62 67 70 77 76 75 72 66 LwA Outlet 73 56 59 64 68 66 66 64 55
LwA Surrounding 67 51 57 58 62 60 55 51 50 LwA Surrounding 66 50 52 57 54 53 54 57 63
With LDR 80-50 With LDR 100-50
LwA Inlet 70 64 60 57 59 61 63 61 59 LwA Inlet 63 59 53 51 49 51 54 52 47
LwA Outlet 74 62 60 61 67 65 67 66 63 LwA Outlet 65 55 53 56 58 55 58 58 51
Measurement point: 0.865 m³/s @ 460 Pa Measurement point: 0.682 m³/s @ 251 Pa

Min. static back pressure: 250 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 71 68 65 72 73 73 70 66 LwA Inlet 73 64 61 61 66 65 66 63 56
LwA Outlet 85 69 71 73 79 79 78 75 69 LwA Outlet 78 62 63 68 73 71 71 68 61
LwA Surrounding 70 59 64 61 63 62 58 53 54 LwA Surrounding 65 52 55 59 60 57 56 54 46
With LDR 100-50 With LDR 100-50
LwA Inlet 74 71 62 57 62 61 64 63 62 LwA Inlet 67 64 55 53 56 54 58 57 53
LwA Outlet 71 69 65 64 68 67 69 68 66 LwA Outlet 70 62 57 60 63 59 63 62 58
Measurement point: 1.23 m³/s @ 606 Pa Measurement point: 1.03 m³/s @ 332 Pa
98 | Rectangular & Square Duct Fans

RS EC NEW! Electrical
accessories
Rectangular

• EC-motors, high level of efficiency


duct fans

• 100% speed controllable


• Integrated motor protection
• Can be installed in any position EC-Vent p. 365
• Potentiometer included for ease of commissioning

The RS EC models have impellers with backward curved blades


and are fitted to EC external rotor motors. These fans have a high
capacity in relation to their compact design. The fans are deliv- CO2RT p. 368
ered with a pre-wired potentiometer (0-10V) which allows you
to easily find the desired working point.
The RSI models are thermally and acoustically insulated with
50 mm mineral wool and perforated sheet steel on the inner
surface. CXE p. 369
Motor protection is integrated in the electronics of the motor.
The casing is manufactured from galvanized steel.

S-ET/STDT
Quick selection p. 373

qv [m³/h]
0 2000 4000 6000 8000 10000 12000 14000
1000
Ps [Pa]

13837/13886/13995/13996/13997/13998

MTV/MTP
900 1 RS 70-40EC
p. 359
2 RS 80-50EC
800 3 RS 100-50EC

700

600

500 MicroREX
p. 379
400

300

200

100 1 2 3 REV p. 380


0

qv [m³/s]

Technical data Smaller sizes coming soon!


RS 70-40 EC 80-50 EC 100-50 EC
Art. no. 17824 17825 17826
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 400 3~
Power W 605 2144 2724
Current A 2.75 3.27 4.15
Max. air flow m3/s 1.34 2.72 3.27
R.p.m. min-1 1403 1509 1400
Max. temp. of transported air °C 60 60 40
Sound pressure level at 3 m dB(A) 60 66 68
Weight kg 37 68.1 92.2
Insulation class, motor F F F
Enclosure class, motor IP 54 IP 54 IP 54
Motor protection Integral Integral Integral
Wiring diagram p. 442-461 58 59 59
Rectangular & Square Duct Fans | 99

Dimensions Ventilation
accessories

duct fans
Rectangular
M
⌀10(8x)
DS p. 399
H (inside)
F (c/c)
D
B

VK p. 412

G (inside)
E (c/c)
C
GFL p. 399

I L

LDR p. 400
J

FFK p. 401
A
K

RB p. 402

RS A B C D E F G H I J K L M
70-40EC 787 465 740 440 720 420 698 398 189 215 524 491 518 VBR p. 406
80-50EC 882 580 840 541 820 520 798 498 182.5 191 644 614 638
100-50EC 982 580 1040 540 1020 520 998 498 287 260 684 634 678

DXRE p. 405

PGK p. 404
100 | Rectangular & Square Duct Fans

Performance
Q [m³/h] Q [m³/h]
Rectangular

0 1000 2000 3000 4000 5000 0 2000 4000 6000 8000 10000
500 1000
duct fans

13995/13996
13837/13886
RS 70-40EC 900 RS 80-50EC
400 800
84
700

300 600 92
Ps [Pa]

Ps [Pa]
500
77
200 400
88 87
95
300
82
72 91
100 200
79
76
100 83
57 64
63 69
0 0

Q [m³/s] Q [m³/s]

800 3000
600
P [W]

2000

P [W]
400
1000
200
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 59 67 73 73 69 67 61 52 LwA Inlet 87 72 79 79 84 79 78 72 64
LwA Outlet 83 58 68 79 77 76 73 66 57 LwA Outlet 93 72 81 88 87 87 82 76 67
LwA Surrounding 67 45 60 65 60 56 54 47 37 LwA Surrounding 73 53 67 66 69 65 64 56 46
Measurement point: 0.802 m³/s @ 336 Pa Measurement point: 1.36 m³/s @ 629 Pa

Q [m³/h]
0 3000 6000 9000 12000
1000
13997/13998

95
RS 100-50EC

800

600
Ps [Pa]

88 98

400

92
81
200
85
64
70
0

Q [m³/s]

3000
P [W]

2000

1000

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 88 75 82 78 82 79 79 74 66
LwA Outlet 93 78 84 87 86 87 83 77 69
LwA Surrounding 75 59 71 67 68 66 66 58 52
Measurement point: 1.31 m³/s @ 876 Pa
Rectangular & Square Duct Fans | 101

duct fans
Rectangular
Reference: Ice Hockey Stadium, Bratislava, Slovakia

Products/Solutions: K, KD and KT fans to ventilate different


areas in the stadium and air distribution products (grilles,
diffusers).
102 | Rectangular & Square Duct Fans

RS Electrical
accessories
Rectangular

• Speed-controllable
duct fans

• Integral thermal contacts


• Can be installed in any position
• Maintenance-free and reliable
S-ET/STDT
The RS models have impellers with backward curved blades and p. 373
external rotor motors. The motor and impeller are mounted on
the access cover to facilitate easy maintenance.
To protect the motor from overheating RS 30-15 to 50-25
have an integral thermal contact with electrical reset, RS 60-35
M to 100-50 have integral thermal contacts with external leads
for connection to a TK triggering device. RTRE p. 356
The fans can be installed in any position and are simple to
couple using DS flexible connections. The casing is manufactured
from galvanized steel.

RE p. 356
Quick selection

3099, 3085, 2486, 2483, 2487, 2488, 2492


3672, 644, 3891, 607, 3896, 2485

1 RS 30-15 1 RS 60-35 L1
2 RS 40-20 M 2 RS 60-35 L3
3 RS 40-20 L 3 RS 70-40 L1 REU p. 356
4 RS 50-25 4 RS 70-40 L3
5 RS 60-35 M1 5 RS 80-50M3
6 RS 60-35 M3 6 RS 80-50L3
7 RS 100-50L3

REE p. 357

3
5 1 2 4 3 5 6 7
1 2 6
4

RTRD/RTRDU
p. 357

Technical data
RS 30-15 40-20 M 40-20 L 50-25 60-35 M1 60-35 M3 60-35 L1**
Art. no. 1435 1439 19530 19531 1795 1796 19554
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 230 1~
Power W 59.9 106 125 129 401 399 626
Current A 0.264 0.461 0.57 0.586 1.91 0.795 2.8
Max. air flow m3/s 0.135 0.238 0.368 0.426 0.941 0.974 1.12
R.p.m. min-1 2431 2597 2797 1329 1365 1371 1308
Max. temp. of transported air °C 70 70 70 70 70 70 70
“ when speed controlled °C 70 70 70 70 70 70 70
Sound pressure level at 3 m dB(A) 48 52 55.5 46 58 58 58
Weight kg 6.5 11 12 16 32 29.6 33.5
Insulation class, motor B B F B F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 54 IP 54 IP 54
Capacitor µF 2 3 5 4 8 – 14
Motor protection Integral Integral Integral Integral S-ET 10 STDT 16 S-ET 10
Speed control, five-step Transformer RE 1.5 RE 1.5 RE 1.5 RE 1.5 RTRE 3* RTRD 2 RTRE 3*
Speed control, five step high/low Transformer REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 3 RTRDU 2 REU 3
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 2* – REE 4*
Wiring diagram p. 442-461 2 2 2 2 6 8 6
* + S-ET 10
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Rectangular & Square Duct Fans | 103

Dimensions Ventilation
I K accessories
ø10,0 (x8)

duct fans
Rectangular
J
DS p. 399
c/c F
D
B

A
L
G VK p. 412
c/c E
C

8,0 LDR p. 400


RS A B C D E F G H I J K L
30-15 402 217 340 190 320 170 298 148 79 120 230 254
40-20 M 502 267 440 240 420 220 398 198 99 125 310 352
40-20 L 502 267 440 240 420 220 398 198 99 125 310.5 352.5
50-25 532 317 540 290 520 270 498 248 125 85.5 366 423 FFK p. 401

ø10,0 (x8) ~1300


I K
J

RB p. 402
c/c F
B
D

VBR p. 406
L

G
c/c E
C

7,5

RS A B C D E F G H I J K L
60-35 M/L 717 402 640 390 620 370 598 348 128 145 490 524
70-40 L 787 452 740 440 720 420 698 398 189,5 215 490 524
80-50 L 882 573 840 541 820 520 798 498 182,5 190 614 644
100-50 L 982 583 1040 541 1020 520 998 498 298,5 290 614 644

RS 60-35 L3 70-40 L1** 70-40 L3 80-50 M3 80-50 L3 100-50 L3


Art. no. 2047 19555 1798 1799 19556 19553
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 667 623 704 1089 1879 2837
Current A 1.59 2.84 1.70 1.97 3.85 4.94
Max. air flow m3/s 1.21 1.59 1.39 1.96 2.3 2.97
R.p.m. min-1 1408 1308 1410 1335 1389 1371
Max. temp. of transported air °C 70 67 70 70 70 70
“ when speed controlled °C 70 67 70 55 70 70
Sound pressure level at 3 m dB(A) 61 60 61 60 66.5 69.6
Weight kg 33.6 40 39 56 68 92
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF - 14 - - - -
Motor protection STDT 16 S-ET 10 STDT 16 STDT 16 STDT 16 STDT 16
Speed control, five-step Transformer RTRD 2 RTRE 5 RTRD 2 RTRD 4 RTRD 7 RTDR 7
Speed control, five step high/low Transformer RTRDU 2 REU 5* RTRDU 2 RTRDU 4 RTRDU 7 RTRDU 7
Speed control, stepless Thyristor – REE 4* – – – –
Wiring diagram p. 442-461 8 6 8 8 8 8
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
104 | Rectangular & Square Duct Fans

Performance
Rectangular
duct fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 47 59 67 59 58 56 50 41 LwA Inlet 71 52 64 66 63 64 59 54 46
LwA Outlet 72 51 56 69 66 64 61 54 46 LwA Outlet 74 51 62 67 70 67 65 60 48
LwA Surrounding 55 29 36 53 48 47 44 38 30 LwA Surrounding 59 37 49 56 54 49 47 41 34
Measurement point: 0.0686 m³/s @ 224 Pa Measurement point: 0.107 m³/s @ 271 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 46 58 71 61 65 62 58 55 LwA Inlet 65 45 63 57 54 56 50 44 36
LwA Outlet 77 48 58 73 68 68 69 62 66 LwA Outlet 68 49 60 61 62 61 57 50 41
LwA Surrounding 62 31 39 61 54 52 50 44 41 LwA Surrounding 53 30 49 49 44 44 41 34 23
Measurement point: 0.202 m³/s @ 400 Pa Measurement point: 0.234 m³/s @ 181 Pa
Rectangular & Square Duct Fans | 105

duct fans
Rectangular
RS 60-35 M1 RS 60-35 M3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 57 61 70 67 64 63 57 48 LwA Inlet 74 59 62 69 68 65 64 59 52
LwA Outlet 82 60 69 79 75 73 71 61 51 LwA Outlet 79 57 65 74 72 71 70 62 53
LwA Surrounding 65 42 55 62 56 56 53 47 37 LwA Surrounding 65 44 54 63 55 55 53 48 39
Measurement point: 0.565 m³/s @ 276 Pa Measurement point: 0.487 m³/s @ 325 Pa

RS 60-35 L3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 63 67 70 69 67 66 60 53 LwA Inlet 78 64 68 72 72 70 69 63 56
LwA Outlet 81 62 69 74 75 75 72 66 57 LwA Outlet 83 60 70 77 77 77 73 67 59
LwA Surrounding 66 47 56 62 59 58 55 50 40 LwA Surrounding 68 50 57 64 60 61 57 53 43
Measurement point: 0.505 m³/s @ 376 Pa Measurement point: 0.543 m³/s @ 416 Pa
106 | Rectangular & Square Duct Fans
Rectangular
duct fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 62 65 72 72 68 68 62 53 LwA Inlet 78 60 67 73 72 69 70 65 57
LwA Outlet 80 62 66 75 74 74 72 65 56 LwA Outlet 81 63 66 77 75 75 72 65 57
LwA Surrounding 67 46 56 64 60 57 54 47 40 LwA Surrounding 68 44 59 64 59 59 58 52 45
Measurement point: 0.873 m³/s @ 336 Pa Measurement point: 0.696 m³/s @ 427 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 60 68 69 74 71 69 64 57 LwA Inlet 83 66 75 73 78 75 74 68 62
LwA Outlet 83 60 69 80 77 76 72 65 57 LwA Outlet 87 68 76 81 82 82 77 70 62
LwA Surrounding 67 47 56 61 62 59 58 51 45 LwA Surrounding 74 53 69 66 67 65 64 57 47
Measurement point: 0.881 m³/s @ 503 Pa Measurement point: 1.03 m³/s @ 672 Pa
Rectangular & Square Duct Fans | 107

duct fans
Rectangular
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 70 77 76 81 79 78 72 66
LwA Outlet 90 73 77 84 85 85 80 74 67
LwA Surrounding 77 62 70 69 72 69 67 60 52
Measurement point: 1.34 m³/s @ 865 Pa
108 | Rectangular & Square Duct Fans

NEW!
RSI EC Electrical
accessories
Rectangular

• EC-motors, high level of efficiency


duct fans

• 100% speed controllable


• Integrated motor protection
• Can be installed in any position EC-Vent p. 365
• Potentiometer included for ease of commissioning

The RSI EC models have impellers with backward curved blades


and are fitted to EC external rotor motors. These fans have a CXE/AV p. 369
high capacity in relation to their compact design. The fans are
delivered with a pre-wired potentiometer (0-10V) which allows
you to easily find the desired working point.
The RSI models are thermally and acoustically insulated with
50 mm mineral wool and perforated sheet steel on the inner S-ET p. 373
surface.
Motor protection is integrated in the electronics of the motor.
The casing is manufactured from galvanized steel.

MTV/MTP p. 359

Quick selection
qv [m³/h]
0 3000 6000 9000 12000 REPT/RETP
1000 p. 370
13837/13840/13995/13997/14002/14005
Ps [Pa]

1 RSI 70-40EC
2 RSI 80-50EC
800 3 RSI 100-50EC

REV p. 380
600

400

200

1 2 3
0

qv [m³/s]

Technical data Smaller sizes coming soon!


RSI 70-40EC 80-50EC 100-50EC
Art. no. 17827 17828 17829
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 400 3~
Power W 605 2144 2724
Current A 2.75 3.27 4.15
Max. air flow m3/s 1.34 2.72 3.27
R.p.m. min-1 1403 1509 1400
Max. temp. of transported air °C 60 60 40
Sound pressure level at 3 m dB(A) 53 61.4 63
Weight kg 72 119 154
Insulation class, motor F F F
Enclosure class, motor IP 54 IP 54 IP 54
Motor protection Integral Integral Integral
Wiring diagram p. 442-461 58 59 59
Rectangular & Square Duct Fans | 109

Dimensions Ventilation
accessories

duct fans
Rectangular
O
ø10,0 (x8) DS p. 399

J
c/c F
D
H

B
VK p. 412

G I
c/c E LDR p. 400
C
A

L N

FFK p. 401
M

~1200
K

RB p. 402
O

VBR p. 406

RSI A B C D E F G H I J K L M N O
70-40EC 808 564 741 441 720 420 697 397 55.5 114 787 202 170 532 596
DXRE p. 405
80-50EC 908 683 841 541 820 520 797 497 55.5 133 882 195 144 656 716
100-50EC 1108 683 1041 541 1020 520 998 498 55.5 133 982 302 215 678 746
110 | Rectangular & Square Duct Fans

Performance
Q [m³/h] Q [m³/h]
Rectangular

0 1000 2000 3000 4000 5000 0 2500 5000 7500 10000


500 1000
duct fans

13995/14005
13837/13840
900 RSI 80-50EC
RSI 70-40 EC
400 800

79 700

300 600 90

Ps [Pa]
Ps [Pa]

500

200 74 400
84 92
92
300

79 84
100 70 200
78

75 100
52 62 82
57 75
0 0

Q [m³/s] Q [m³/s]

3000
600

P [W]
P [W]

400 2000

200 1000

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 53 65 65 65 59 57 53 47 LwA Inlet 83 71 78 76 78 72 72 68 61
LwA Outlet 84 61 71 80 78 76 74 65 57 LwA Outlet 93 72 81 88 87 87 82 76 67
LwA Surrounding 60 36 52 54 55 53 50 46 44 LwA Surrounding 68 52 62 61 62 60 59 54 48
Measurement point: 0.802 m³/s @ 336 Pa Measurement point: 1.36 m³/s @ 629 Pa

Q [m³/h]
0 3000 6000 9000 12000
1000
13997/14002

900 93
RSI 100-50EC
800

700

600
Ps [Pa]

500 86
95

400

300
89
78
200
82
100 61
68
0

Q [m³/s]

3000
P [W]

2000

1000

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 83 76 80 73 74 69 69 65 59
LwA Outlet 93 78 84 87 86 87 83 77 69
LwA Surrounding 70 57 66 59 60 61 62 57 52
Measurement point: 1.31 m³/s @ 876 Pa
Rectangular & Square Duct Fans | 111

duct fans
Rectangular
Reference: Skåne University Hospital, Malmö, Sweden

For the new emergency and infectious diseases unit at UMAS, Systemair has delivered 18 Air
Handling Units in sizes DV 40 to DV 150 together with other Systemair products including duct
fans, roof fans and smoke exhaust fans.

UMAS is one of the leading hospitals for infectious diseases in the world and the new clinic at
the Skåne University Hospital is the largest investment ever by UMAS. The total costs are more
than 125 million Euros.

The new emergency and infectious diseases unit at UMAS was designed by the Danish
Architects C.F. Möller A/S, Aarhus and the Ventilation systems were designed by Incoord AB,
Stockholm.
112 | Rectangular & Square Duct Fans

RSI Electrical
accessories
Rectangular

• Speed-controllable
duct fans

• Integral thermal contacts


• Can be installed in any position
• Maintenance-free and reliable
S-ET/STDT
The RSI models have impellers with backward curved blades and p. 373
external rotor motors. The motor and impeller are mounted on the
access cover to facilitate easy maintenance. The RSI models are
thermally and acoustically insulated with 50 mm mineral wool,
with perforated steel panels on the inner surface.
To protect the motor from overheating the RSI fans have integral
thermal contacts with external leads for connection to a TK trigger- RTRE p. 356
ing device.
The fans can be installed in any position and are simple to cou-
ple using DS flexible connections. The casing is manufactured from
galvanized steel.

REU p. 356
Quick selection
3896 , 2362 , 3110 , 3109 , 2371

2379, 2389, 2384, 2393


1 RSI 60-35 M1 1 RSI 70-40 L3
REE p. 357
2 RSI 60-35 M3 2 RSI 80-50 M3
3 RSI 60-35 L3 3 RSI 80-50 L3
4 RSI 100-50 L3

RTRD/RTRDU
p. 357

1 2 3 1 2 3 4

Technical data
RSI 60-35 M1 60-35 M3 60-35 L1** 60-35 L3 70-40 L1** 70-40 L3
Art. no. 1788 1789 19558 2043 19559 1791
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~
Power W 401 399 626 667 623 704
Current A 1.91 0.795 2.8 1.59 2.84 1.70
Max. air flow m3/s 0.941 0.974 1.12 1.21 1.59 1.39
R.p.m. min-1 1365 1371 1308 1408 1308 1410
Max. temp. of transported air °C 70 70 70 70 67 70
“ when speed controlled °C 70 70 70 70 67 70
Sound pressure level at 3 m dB(A) 50 48 52 57 51 51
Weight kg 59 58 63 64 78 78
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor 8 – 14 – 14 –
Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16
Speed control, five-step Transformer RTRE 3 RTRD 2 RTRE 3 RTRD 2 RTRE 5 RTRD 2
Speed control, five step high/low Transformer REU 3* RTRDU 2 REU 3* RTRDU 2 REU 5* RTRDU 2
Speed control, stepless Thyristor REE 2* – REE4* – REE4* –
Wiring diagram p. 442-461 6 8 6 8 6 8
* + S-ET 10
** Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Rectangular & Square Duct Fans | 113

Dimensions Ventilation
accessories

duct fans
Rectangular
L N

ø10,0 (x8)

M
J
DS p. 399
~1200

c/c F
D
H

K
O
VK p. 412
G I
c/c E
C
A

LDR p. 400

RSI A B C D E F G H I J K L M N O
60-35 708 492 640.5 391 620 370 598 347.5 55 92.5 717 139.5 99.5 532 597
FFK p. 401
70-40 808 542 741 441 720 420 697 397 55.5 92.5 787 201 169.5 532 597
80-50 908 662 841 541 820 520 797 497 55.5 112.5 882 194 144.5 656 717
100-50 1108 662 1041 541 1020 520 997 497 55.5 112.5 982 310 244.5 656 717

RB p. 402

VBR p. 406

RSI 80-50 M3 80-50 L3 100-50 L3


Art. no. 1792 19560 19557
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~
Power W 1089 1879 2837
Current A 1.97 3.85 4.94
Max. air flow m3/s 1.96 2.3 2.97
R.p.m. min-1 1335 1389 1371
Max. temp. of transported air °C 70 70 70
“ when speed controlled °C 55 70 70
Sound pressure level at 3 m dB(A) 53 61 62
Weight kg 104 119 154
Insulation class, motor F F F
Enclosure class, motor IP 54 IP 54 IP 54
Capacitor - - -
Motor protection STDT 16 STDT 16 STDT 16
Speed control, five-step Transformer RTRD 4 RTRD 7 RTRD 7
Speed control, five step high/low Transformer RTRDU 4 RTRDU 7 RTRDU 7
Speed control, stepless Thyristor – – –
Wiring diagram p. 442-461 8 8 8
114 | Rectangular & Square Duct Fans

Performance
Rectangular
duct fans

RSI 60-35 M3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 66 43 54 62 60 56 55 50 42 LwA Inlet 67 55 62 62 60 55 55 51 47
LwA Outlet 79 48 61 75 73 73 71 61 50 LwA Outlet 79 57 65 74 72 71 70 62 53
LwA Surrounding 57 29 47 55 48 47 45 38 29 LwA Surrounding 55 29 47 50 48 47 45 38 35
With LDR 60-35 With LDR 60-35
LwA Inlet 52 43 46 48 42 37 42 39 34 LwA Inlet 59 55 55 49 43 37 42 41 39
LwA Outlet 65 48 54 61 56 54 57 50 42 LwA Outlet 66 57 58 61 55 53 57 52 45
Measurement point: 0.565 m³/s @ 276 Pa Measurement point: 0.487 m³/s @ 325 Pa

RSI 60-35 L1 RSI 60-35 L3

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 61 66 66 64 58 57 54 47 LwA Inlet 72 55 67 67 66 59 59 59 52
LwA Outlet 82 66 69 75 75 78 75 62 53 LwA Outlet 83 60 70 77 77 77 73 67 59
LwA Surrounding 60 40 54 55 52 49 48 43 38 LwA Surrounding 64 26 56 59 57 53 54 55 48
With LDR 60-35 With LDR 60-35
LwA Inlet 63 60 59 52 46 40 44 44 39 LwA Inlet 63 55 60 54 49 40 46 49 44
LwA Outlet 70 66 62 61 57 59 61 52 45 LwA Outlet 69 60 63 64 60 58 60 57 51
Measurement point: 0.505 m³/s @ 376 Pa Measurement point: 0.543 m³/s @ 416 Pa
Rectangular & Square Duct Fans | 115

duct fans
Rectangular
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 57 62 62 60 57 56 51 45 LwA Inlet 68 57 62 62 62 57 58 55 49
LwA Outlet 80 62 67 75 74 74 72 65 56 LwA Outlet 81 63 66 77 75 75 72 65 57
LwA Surrounding 58 41 47 53 51 50 48 46 43 LwA Surrounding 58 39 46 51 53 50 48 44 39
With LDR 70-40 With LDR 70-40
LwA Inlet 60 57 54 51 46 43 46 43 40 LwA Inlet 61 57 55 51 48 43 48 47 43
LwA Outlet 70 62 59 64 60 60 62 57 51 LwA Outlet 70 63 59 65 61 60 62 57 51
Measurement point: 0.873 m³/s @ 336 Pa Measurement point: 0.696 m³/s @ 427 Pa

Q [m³/h]
0 1440 2880 4320 5760 7200 8640 10080
1000

12647/12660
RSI 80-50 L3
750
88
Ps [Pa]

86
500
84

89
82
86
85
250
75 82

84

1 2 3 4 5
0
0 0.4 0.8 1.2 1.6 2 2.4 2.8
Q [m³/s]

2000
5

2
[W]

1000

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 58 64 62 64 61 61 60 56 LwA Inlet 77 64 72 69 71 67 66 60 55
LwA Outlet 83 59 68 80 77 76 72 65 57 LwA Outlet 87 68 76 81 82 82 77 70 62
LwA Surrounding 60 40 51 53 53 52 49 49 50 LwA Surrounding 68 51 63 61 62 59 58 53 41
With LDR 80-50 With LDR 80-50
LwA Inlet 64 58 58 54 54 50 53 54 53 LwA Inlet 68 63 63 58 57 54 57 55 55
LwA Outlet 75 59 62 72 67 65 64 59 54 LwA Outlet 79 70 68 73 72 72 71 66 61
Measurement point: 0.881 m³/s @ 503 Pa Measurement point: 1.03 m³/s @ 672 Pa
116 | Rectangular & Square Duct Fans

Q [m³/h]
0 3000 6000 9000 12000
Rectangular

1200
duct fans

RSI 100-50 L3

900 91

88
Ps [Pa]

600
85
92

81 89
300 85
73 82

73
0
0 0.83 1.67 2.5 3.33
Q [m³/s]

3000
5
2000
P [W]

2
1000

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 69 74 69 73 70 71 66 61
LwA Outlet 90 73 77 84 85 85 80 74 67
LwA Surrounding 69 57 64 60 60 61 59 53 47
With LDR 100-50
LwA Inlet 72 68 67 63 62 59 60 56 56
LwA Outlet 83 73 72 76 75 76 74 69 63
Measurement point: 1.34 m³/s @ 865 Pa
Rectangular & Square Duct Fans | 117

duct fans
Rectangular
118 | Rectangular & Square Duct Fans

KPB
Rectangular

• Double inlet belt driven range with airflow


duct fans

from 0.208 to 13.9 m³/s


• L ow sound level
• Easy to install

KPB is a range of supply or extract box fans for inline operation. The fan
is suitable for indoor and outdoor installation with low to medium pres-
IE2
2009/640/EG
sure drop and very good sound performance.
The unit is fitted with a forward curved double inlet impeller and IP55
F class IE2 motor.
The casing consists of an aluminium frame with single skin panels
made of galvanized steel (double skin available on request).
The fan is mounted on 4 anti-vibration rubber mounts. Sizes 20/20
to 30/28 have a baseframe instead.
Outlet connected to the casing via an 18 mm thick rubber joint acting
as a flexible seal connection (sizes 20/20 to 30/28 have a flexible can-
vas).
Accessories: Outlet and inlet hood, roof, damper, double skin panels,
inlet panel with rectangular flange.

Technical data
KPB 7-7 9-7 9-9 10-8 10-10 12-9 12-12
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power min./max. kW 0.25-1.5 0.25-1.5 0.25-1.5 0.25-1.5 0.25-2.2 0.37-3 0.37-3
Max. air flow m³/s 0.8 1.1 1.3 1.4 1.7 1.9 2.5
R.p.m. min-1 1450 1450 1450 1450 1450 1450 1450
Max. temp. of transported air °C 50 50 50 50 50 50 50
Insulation class, motor F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b

KPB 15-11 15-15 18-18 20-20 22-22 25-25 30-28


Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power min./max. kW 0.55-4 0.55-5.5 0.75-7.5 1.5-7.5 2.2-11 2.2-11 2.2-15
Max. air flow m³/s 2.6 3.6 5.4 6.9 8.3 11.1 13.9
R.p.m. min-1 1450 1450 1450 1450 1450 1450 1450
Max. temp. of transported air °C 50 50 50 50 50 50 50
Insulation class, motor F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b 13a/14b
Rectangular & Square Duct Fans | 119

Dimensions

duct fans
Rectangular
A B
F
E

C
D

Inlet options
Manual damper Rectangular inlet
KPB A B C D E F L Length H Height L Length H Height
7-7 600 450 450 272 251 68 300 288 390 390
9-7 / 9-9 700 550 550 336 304 94 400 416 490 490
10-8 / 10-10 750 650 600 371 330 85 500 416 590 540
12-9 / 12-12 900 800 700 434 383 112 650 544 740 640
15-11 / 15-15 1000 950 800 508 443 128 800 672 890 740
18-18 1150 1100 1000 594 518 120 900 800 1000 900

Inlet options
Manual damper
KPB A A’ B C C’ D E F G H J L Length H Height
20-20 1550 1780 1350 1250 1330 610 610 193 1270 900 175 1000 1056
22-22 1650 1880 1350 1250 1330 661 701 112 1270 900 175 1000 1056
25-25 1700 1930 1450 1450 1530 771 800 186 1370 830 40 1200 1184
30-28 2000 2230 1700 1700 1780 896 939 206 1620 780 340 1400 1312
120 | Rectangular & Square Duct Fans

Performance
Rectangular

7-7 9-7
duct fans

150 150
140 67% 65% 60%
140 65% 51%
130 Not usable 130 η 59%
120 46% 50% 49%
Not recommended η 3100
120
110 Not recommended 110
45% 2400
100 100
90 39% 90
80 80 2000
2800
70 70
1800
60 60

50 50 1600
2400

40 2200 40
1400

2000 1300
30 30
1200
1800
1100
1600
20 20 1000

1400 900

800
1200

10 10
700

1000

600 Not usable


Not recommended
Not recommended
800
V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000
3
V(m /h) 250 500 1000 1500 2000 3000 4000 5000
3

C 2 (m/s) 2 3 4 5 10 15 20 30 C (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

9-9 10-8
150 150
140 60% 70% 69% 63% 140
67% 53%
130 130 68%
η 69% 62% 2200
120 120 66%
110 110 η 60% 52%
100 2400 100
90 90
80 80
1800
70 2000 70 1700

60 60 1600
1800
1500
50 50
1600 1400

40 1500 40 1300

1400
1200
30 1300 30
1100
1200
1000
1100
20 20
900
1000

900 800

800 700
10 10

700
600

Not usable Not usable


600 Not recommended Not recommended
Not recommended Not recommended

V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000
3
V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000
3

C 2 (m/s) 2 3 4 5 10 15 20 30 40 C (m/s) 2 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70


Rectangular & Square Duct Fans | 121

duct fans
Rectangular
10-10 12-9
150 150
140 140 η 72% 73% 67%
56%
1800
130 62% 56% 130
74%
120 65% 120
2200 47%
110 64% 110
100 η 60% 100 1600
90 1800 90
80 1700 80 1400

70 70 1300
1600
60 60 1200
1500

50 1400 50 1100

1300 1000
40 40
1200
900
30 1100 30

800
1000

20 900 20 700

800
600

700

10 500
10

600

Not usable Not usable


Not recommended Not recommended
Not recommended Not recommended

V(m /h) 750 1000 1500 2000 3000 4000 6000 8000 10000 14000
3
V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000
3

C 2 (m/s) 2 3 4 5 10 15 20 30 C 2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

12-12
150
140
130 68% 60% 1800
120 69%
110
100
η 65%
1500
90
1400
80

70 1300

60 1200

50 1100

40 1000

900
30

800

20 700

600

10 500

Not usable
Not recommended
Not recommended

V(m /h) 1000 1500 2000 3000 4000 6000 8000 10000 15000 20000
3

C 2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

Note: All fan curves are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point.
122 | Rectangular & Square Duct Fans
Rectangular

15-11
15-11 15-15
15-15
duct fans

150 150
140 64% 140 65%
58% 64%
130 130 η 58% 62% 54%
66% 1400
120 η 64% 1400 120
110 110
100 100
1200
90 1200 90
80 80 1100
1100
70 70
1000
1000
60 60

900
50 900 50

40 40 800
800

700
30 700 30

600
600
20 20

500
500

10 10 400
400

Not usable Not usable


Not recommended Not recommended
Not recommended Not recommended

V(m /h) 1000 1500 2000 3000 4000 6000 8000 10000 15000 20000 V(m /h) 1500 2000 3000 4000 6000 8000 10000 15000 20000 30000
3 3

C (m/s) 2 3 4 5 10 15 20 30 40 C2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

18-18
18-18 20-20
150 120 6.0
140 110 5.0 1200
130 1200
71% 100 Not usable 1000
120 73% 64%

9.
Not recommended 4.0 70% 70%

0
110 90 64% 900
η
70% Not recommended 65%
100 800
80 52%
90
3.0 h 1000
1000 70 700
80
900 600
70 900 60 2.0

60 50 500
1.5 800
800
50
40 400
1.0 700
700
40
0.8
)

300
kW

30
Dpt (mm H 2O )

PA (

30 600 600 P a (N /m )
2

0.6

0.5

20 200
0.4
500 500
20
)
-1
min

0.3
450 450
n(

400 400

10 100
10 350
350

Not usable 300


Not recommended
Not recommended

V(m /h) 2000 3000 4000 6000 800010000 15000 20000 30000 40000
3
2000 3000 4000 6000 8000 10000 15000 20000 30000 40000 V(m3/h)
C 2 (m/s) 3 4 5 10 15 20 30 40 C 2 (m/s) 2 3 4 5 10 15 20 30

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70


Rectangular & Square Duct Fans | 123

duct fans
Rectangular
22-22 25-25
120 8.0 120
1200 69% 66% 1200
110 64% 110 10 54%
Not usable 6.0 h 65%
1000 67% 13 1000
68% 54%

11
100 100 h
Not recommended 8.0

.5
5.0 900 900
90 Not recommended 90
900 800 800
80 4.0 80 6.0

70 700 5.0 700 700


70
3.0
60 600 650 600
60 4.0
800
500 600
50 2.0 50 3.0 500

550
700
1.5

)
400 400

kW
40 40
2.0

PA (
500

1.0 600 300 1.5


30 30 300
450
Dpt (mm H 2O )

Dpt (mm H 2O )
)
kW

P a (N /m )

P a (N /m )
0.8

2
PA (

1.0 400
0.6 500
20 200 0.8 200
20

450 350

)
-1
0.4 0.6

min
n(
)
-1

400
min

300
0.4
n(

350 100
10 10 100

250

300

Not usable
Not recommended
Not recommended

2000 3000 4000 6000 8000 10000 15000 20000 30000 40000 V(m3/h) 5000 10000 15000 20000 30000 40000 60000 80000 100000 V(m3/h)
C 2 (m/s) 2 3 4 5 10 15 20 C 2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

30-28
120 15 78% 75% 67% 1200
110 h 73%
10
100 1000

90 8.0 900
600
80 800
6.0 550
70 700
5.0
500 600
60
4.0

50 450 500
3.0

40 400
400
)
kW

2.0
PA (

30 1.5 350 300


Dpt (mm H 2O )

P a (N /m )
2

1.0 300
20 200
0.8
)
-1
min

0.6
250
n(

10 100
200

Not usable
Not recommended
Not recommended

5000 10000 15000 20000 30000 40000 60000 80000 100000 V(m3/h)
C 2 (m/s) 2 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

Note: All fan curves are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point.
124 | Rectangular & Square Duct Fans

MUB EC Electrical
accessories
• 100% speed controllable
duct fans
Square

• Integrated electronic motor protection


• Low noise level
• Installation in any mounting position
MTP 10
• Safe and maintenance free operation
p. 359

The MUB EC fans are driven by EC-external rotor motors. These are
energy saving motors with high efficiency.
The input voltage for single phase units can vary between 200 and
277V, for three phase units between 380 and 480V. Speed control
CXE/AV
by a 0-10V signal. From size 450 the motor has an output voltage of p. 369
10V and 20V for an external potentiometer.
MUB EC is equipped with impellers with backward curved blades,
manufactured from aluminium. Mini MUB 200EC is manufactured
from plastic PA6 25GV.
The casing consists of an aluminium frame with fibreglass rein- EC-Vent
forced plastic corners of PA6; highly shock-resistant. The double skin p. 365
panels are manufactured from galvanized steel with 20 mm mineral-
wool insulation. The panels are removable, any outlet side can be
chosen, allowing flexible ventilation solutions.
Installation in any mounting position is possible.

qv [m³/h]
Quick selection 0 5000 10000 15000 20000 25000
1200
Ps [Pa]

6740/6741/6827/6828/12843/13249
1 MUB 042 450EC-A2
2 MUB 042 450EC-A2-K
33032, 6773, 6816, 6669

3 MUB 042 500EC-A2


4 MUB 062 560EC-A2
1 Mini MUB EC 5 MUB 062 630EC-A2
2 MUB 025 315EC-A2 900 6 MUB 100 630EC
7 MUB 100 710EC
3 MUB 025 355EC-A2
4 MUB 042 400EC-A2

1
600

300

1 2 3 4 7
6
5
2 4
3
0
0 2 4 6 8
qv [m³/s]

Technical data
MUB Mini MUB 025 315 EC 025 355 EC 042 400 EC 042 450 EC 042 450 EC
Art. no. 33207 30676 30670 30209 30610 31380
Techn. data is relating to 90° outlet 200 EC EC-A2 EC-A2 EC-A2 EC-A2 EC-A2-K
Voltage/Frequency V/50/60 Hz 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 230 1~
Power W 89.1 168 388 378 1055 597
Current A 0.701 1.19 2.37 2.26 1.79 2.71
Max. air flow m3/s 0.174 0.637 0.884 1.08 1.76 1.41
R.p.m. min-1 3965 1694 1639 1339 1562 1297
Max. temp. of transported air °C 40 60 60 60 60 60
“ when speed controlled °C 40 60 60 60 60 60
Sound pressure level at 3 m dB(A) 47 47 53 51 63 56
Weight kg 8.1 29 29.5 45,5 52.5 52.5
Insulation class, motor B B B B F B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 54 IP 54
Speed control, electronic CXE/AVC CXE/AVC CXE/AVC CXE/AVC CXE/AVC CXE/AVC
Speed control, electronic MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10
Wiring diagram p. 442-461 23a 23b 23b 23b 27 28
Rectangular & Square Duct Fans | 125

Dimensions Ventilation
accessories

duct fans
Square
Mini MUB

FGV p. 413

SRKG p. 413

UGS p. 413

WSG p. 413

MUB EC

MUB £A £B £C øD øE £F
025 315EC-A2 500 500 420 315 200 40
025 355EC-A2 500 500 420 355 224 40
F

042 400EC-A2 670 670 590 400 253 40


A

042 450EC-A2 670 670 590 454 286 70


042 450EC-A2-K 670 670 590 450 286 70
042 500EC-A2 670 670 590 504 321 70
062 560EC-A2 800 800 720 560 360 70
062 630EC-A2 800 800 720 630 407 70
100 630EC 1000 1000 920 710 444 70

øE 100 710EC 1000 1000 920 806 470 73

øD
C
B

MUB 042 500 EC 062 560 EC 062 630 EC 100 630 EC 100 710EC
Art. no. 30314 30235 30207 34168 36379
Techn. data is relating to 90° outlet EC-A2 EC-A2 EC-A2 EC-A2 EC-A2
Voltage/Frequency V/50/60 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 1046 1976 2480 2924 6434
Current A 1.69 3.05 3.80 4.30 8.96
Max. air flow m3/s 1.93 3.00 3.57 4.96 7.45

R.p.m. min-1
1340 1358 1209 1139 1205
Max. temp. of transported air °C 60 60 60 60 40
“ when speed controlled °C 60 60 60 60 40
Sound pressure level at 3 m dB(A) 56 57 67 68 74
Weight kg 56 101 96.5 167 199
Insulation class, motor B F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54
Speed control, electronic CXE/AVC CXE/AVC CXE/AVC CXE/AVC CXE/AVC
Speed control, electronic MTP 10 MTP 10 MTP 10 MTP 20 MTP 20
Wiring diagram p. 442-461 27 27 27 47 47
126 | Rectangular & Square Duct Fans

Performance
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 55 64 68 71 65 64 60 53
LwA Outlet 80 59 64 71 78 72 68 64 56
LwA Surrounding 54 32 43 45 51 49 42 32 24
Measurement point: 0.0869 m³/s @ 351 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 35 62 57 63 62 57 55 48
LwA Outlet 72 48 70 61 65 64 59 55 47
LwA Surrounding 54 22 50 45 48 45 45 33 23
Measurement point: 0.319 m³/s @ 242 Pa
Rectangular & Square Duct Fans | 127

duct fans
Square
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 43 64 65 70 66 68 66 58
LwA Outlet 77 43 69 66 70 70 69 66 58
LwA Surrounding 60 35 53 53 54 51 53 50 35
Measurement point: 0.486 m³/s @ 383 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 41 61 61 65 65 63 59 51
LwA Outlet 74 49 68 64 67 67 66 60 53
LwA Surrounding 59 31 52 52 49 54 52 43 29
Measurement point: 0.593 m³/s @ 321 Pa
128 | Rectangular & Square Duct Fans
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 46 68 70 73 71 70 65 61
LwA Outlet 83 68 76 71 76 78 75 68 63
LwA Surrounding 70 29 67 62 61 61 59 52 44
Measurement point: 0.968 m³/s @ 605 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 43 62 64 69 70 75 72 61
LwA Outlet 78 48 64 64 70 72 73 70 59
LwA Surrounding 64 33 53 53 53 55 61 56 38
Measurement point: 0.847 m³/s @ 377 Pa
Rectangular & Square Duct Fans | 129

duct fans
Square
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 46 71 69 71 70 69 65 60
LwA Outlet 80 49 70 71 75 74 71 67 64
LwA Surrounding 65 35 55 61 59 57 56 51 39
Measurement point: 1.06 m³/s @ 509 Pa

MUB 062 560EC-A2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 51 71 75 73 74 72 67 63
LwA Outlet 77 57 70 70 71 70 67 64 58
LwA Surrounding 71 40 66 67 61 60 58 48 36

Measurement point: 1.65 m³/s @ 675 Pa


130 | Rectangular & Square Duct Fans
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 54 76 76 73 74 73 69 65
LwA Outlet 83 59 75 78 76 75 72 68 64
LwA Surrounding 76 47 75 67 62 60 59 49 39
Measurement point: 1.96 m³/s @ 690 Pa

Q [m³/h] Q [m³/h]
0 5000 10000 15000 20000 0 5000 10000 15000 20000
800 1000
12842

MUB 100 630EC MUB 100 630EC 12843

800
600

600
Ps [Pa]

Ps [Pa]

400

400

200
200

1 5 1 5
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Q [m³/s] Q [m³/s]

3000 3000
5
5
2000 2000
P [W]
P [W]

1000 1000
1 1
0 0

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 55 76 77 74 75 74 70 66
LwA Outlet 84 59 76 78 77 75 73 69 65
LwA Surrounding 77 48 75 68 63 61 60 50 40
Measurement point: 2.98 m³/s @ 595 Pa
Rectangular & Square Duct Fans | 131

Q [m³/h] Q [m³/h]

duct fans
Square
0 5000 10000 15000 20000 25000 0 5000 10000 15000 20000 25000
1200 1200

13248

13249
MUB 100 710EC MUB 100 710EC
1000

900

800
Ps [Pa]

Ps [Pa]
600 600

400

300

200

1 5 1 5
0 0
0 2 4 6 8 0 2 4 6 8
Q [m³/s] Q [m³/s]

8000 8000
5
P [W]

P [W]
5
4000 4000

1 1
0 0

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 58 80 81 78 79 78 74 70
LwA Outlet 88 63 80 82 81 79 77 73 69
LwA Surrounding 81 52 79 72 67 65 64 54 44
Measurement point: 4.47 m³/s @ 850 Pa
132 | Rectangular & Square Duct Fans

MUB Electrical
accessories
• Speed-controllable
duct fans
Square

• Low sound level


• Flexible airflow direction due to removable panels
• Installation in any mounting position
S-ET/STDT
• Maintenance-free and reliable p. 373

IE2
2009/640/EG
The MUB fans have impellers with backward curved blades, manufac-
tured from polyamide (size 355), aluminium (size 400 - 710), welded
steel painted in RAL 5002 (size 100 630D4-L). MUB 355 - 500E4 and
630DV are equipped with external rotor motors, fully speed control-
lable by transformer. MUB 500D4 - 710 are driven by an IEC standard RTRE p. 356
motor. MUB with IE2 motor: speed control is only possible via frequency
converter. The three phase motors are D/Y connected for two speed
operation. Motor protection is done by thermal contacts, which have to
be connected to an external TK triggering device. MUB with IE2 motors:
motor protection by cold conductors (PTC).
REU p. 356
The casing consists of a corrosion-resistant aluminum frame with
fiberglass reinforced plastic corners of PA6; highly shock resistant. The
double skin panels are manufactured from galvanized steel with 20 mm
mineral wool insulation.
REE p. 357
Quick selection
6726, 6734, 6739, 6748, 6751, 6755, 6777, 6779

6763 , 9782 , 9784 , 9791 , 9468 , 9793 , 6794 , 9798 , 9795


1 MUB 025 355 E4-A2 1 MUB 042 500 E4-A2
2 MUB 025 355 DV-A2 2 MUB 042 500 D4-A2 IE2
3 MUB 042 400 E4-A2 3 MUB 062 560 D4-A2 IE2 RTRD/RTRDU
4 MUB 042 400 DV-A2
5
4 MUB 062 560 D6-A2 IE2 p. 357
MUB 042 450 E4-A2 5 MUB 062 630 D4-A2 IE2
6 MUB 042 450 DV-A2 6 MUB 062 630 D6-A2 IE2
7 MUB 042 499 E4-A2 7 MUB 062 630 DV
8 MUB 042 499 DV-A2 8 MUB 100 630 D4-L IE2
9 MUB 100 710 D6-A2 IE2
FRQ p. 361
1
1 2
2 7 5 8

9
4 6 3

3 4 5 6 8 7

S-DT2 SKT
p. 381

Technical data
MUB 025 355 025 355 042 400 042 400 042 450 042 450 042 499 042 499 042 500
Art. no. 2104 2775 2116 2112 2124 2123 2134 2133 2141
Techn.data is relating to 90° outlet E4-A2 DV-A2 E4-A2 DV-A2 E4-A2 DV-A2 E4-A2 DV-A2 E4-A2
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~
Power W 264 243 467 430 756 726 1023 1457 1310
Current A 1.19 0.541 2.14 0.826 3.33 1.32 4.72 1.64 5.78
Max. air flow m3/s 0.741 0.731 1.07 1.08 1.48 1.52 1.87 1.76 2.13
R.p.m. min-1 1399 1349 1320 1339 1249 1277 1270 1210 1332
Max. temp. of transported air °C 40 40 40 40 60 40 40 40 40
Sound pressure level at 1 m dB(A) 46 46 49 49 52 52 48 48 56
Weight kg 29 31 48 48 53 53 59 53 57
Insulation class, motor B B F F F F F F F
Enclosure class, motor IP 44 IP 44 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor 8 – 8 – 16 – 20 – 30
Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10
Speed control, five step Transformer RTRE 3 RTRD 2 RTRE 3 RTRD 2 RTRE 5 RTRD 2 RTRE 5 RTRD 2 RTRE 7
Speed control, five step high/low Transformer REU 1.5* RTRDU 2 REU 3* RTRDU 2 REU 5* RTRDU 2 REU 5 RTRDU 2 REU 7
Speed control, two step – S-D2SKT – S-D2SKT – S-D2SKT – S-D2SKT –
Speed control, stepless Thyristor REE 2* – REE 4* – REE 4* – – – –
Wiring diagram p. 442-461 5 16 5 16 6 18a 6 18a 6
* + S-ET 10
Rectangular & Square Duct Fans | 133

Dimensions Ventilation
accessories

duct fans
Square
MUB £A £B £C £D øD øE
025 355 500 500 420 378 355 224
042 400 670 670 590 548 404 253
042 450 670 670 590 548 454 286 FGV p. 413

A
042 499 670 670 590 548 504 321
042 500E4-A2 670 670 590 548 504 321
062 630DV-B2 800 800 720 678 635 407

SRKG p. 413

øE
øD
D
C
B
UGS p. 413

WSG p. 413
MUB £A £B £C øD øE F
042 500 670 670 590 504 321 300
062 560 800 800 720 570 361 321
062 630 800 800 720 635 407 321
100 630 1000 1000 920 630 389 378
A

100 710 1000 1000 920 878 715 460


F

øE
øD
C

B

MUB 042 500 062 560 062 560 062 630 062 630 062 630 100 630 100 710
Art. no. 33542 33543 33544 33545 33546 36150 33549 33548
Techn.data is relating to 90° outlet D4-A2 IE2 D4-A2 IE2 D6-A2 IE2 D4-A2 IE2 D6-A2 IE2 DV D4-L IE2 D6-A2 IE2
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power at shaft (P2) W 1356 2437 770 4411 1407 3890 5477 2444
Current A 3.39 4.64 1.98 8.12 3.61 6.4 9.54 5.1
Max. air flow m3/s 2.16 3.25 2.18 4.19 2.77 4.17 5.65 4.48
R.p.m. min-1 1400 1420 905 1450 940 1370 1435 945
Max. temp. of transported air °C 40 40 40 40 40 40 40 60
Sound pressure level at 3 m dB(A) 55 56 47 68 53 69 74 59
Weight kg 66 102 90 114 101 103 184 154
Insulation class, motor F F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 54 IP 55 IP 55
Capacitor - - - - - - - -
Motor protection – – – – – STDT 16 – –
Speed control, five step - - - - - RTRD 14 - -
Speed control, two step – – – – – S-D2SKT – –
Speed control, frequency converter* FRQ FRQ FRQ FRQ FRQ – FRQ FRQ
Wiring diagram p. 442-461 17a 17a 17a 17b 17a 16a 17b 17a
* Frequency converters are available with or without sine filter, and stepless or with five step switch (see page 361)
134 | Rectangular & Square Duct Fans

Performance
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 55 57 61 63 62 59 54 47
LwA Outlet 70 57 59 63 65 64 61 56 49
LwA Surrounding 62 49 51 55 57 56 53 48 41

Measurement point: 0.407 m³/s @ 254 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 55 57 61 63 62 59 54 47
LwA Outlet 70 57 59 63 65 64 61 56 49
LwA Surrounding 62 49 51 55 57 56 53 48 41
Measurement point: 0.402 m³/s @ 238 Pa
Rectangular & Square Duct Fans | 135

duct fans
Square
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 59 61 65 67 66 63 58 51
LwA Outlet 74 61 63 67 69 68 65 60 53
LwA Surrounding 56 43 45 49 51 50 47 42 53
Measurement point: 0.588 m³/s @ 306 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 59 61 65 67 66 63 58 51
LwA Outlet 74 61 63 67 69 68 65 60 53
LwA Surrounding 56 43 45 49 51 50 47 42 35
Measurement point: 0.647 m³/s @ 280 Pa
136 | Rectangular & Square Duct Fans
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 62 64 68 70 69 66 61 54
LwA Outlet 77 64 66 70 72 71 68 63 56
LwA Surrounding 59 46 48 52 54 53 50 45 38

Measurement point: 0.816 m³/s @ 348 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 61 63 67 69 68 65 60 53
LwA Outlet 76 63 65 69 71 70 67 62 55
LwA Surrounding 59 46 48 52 54 53 50 45 38
Measurement point: 0.834 m³/s @ 366 Pa
Rectangular & Square Duct Fans | 137

duct fans
Square
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 65 67 71 73 72 69 64 57
LwA Outlet 80 67 69 73 75 74 71 66 59
LwA Surrounding 55 42 44 48 50 49 46 41 34
Measurement point: 0.936 m³/s @ 428 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 76 63 65 69 71 70 67 62 55
LwA Outlet 78 65 67 71 73 72 69 64 57
LwA Surrounding 55 42 44 48 50 49 46 41 34
Measurement point: 0.879 m³/s @ 380 Pa
138 | Rectangular & Square Duct Fans
duct fans
Square

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 66 68 72 74 73 70 65 58
LwA Outlet 81 68 70 74 76 75 72 67 60
LwA Surrounding 63 50 52 56 58 57 54 49 42
Measurement point: 1.06 m³/s @ 515 Pa

MUB 042 500D4-A2 IE2


MUB 042 500D4-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 64 66 70 72 71 68 63 56
LwA Outlet 79 66 68 72 74 73 70 65 58
LwA Surrounding 62 49 51 55 57 56 53 48 41
Measurement point: 1.19 m³/s @ 564 Pa
Rectangular & Square Duct Fans | 139

duct fans
Square
MUB 062 560D4-A2 IE2 MUB 062 560D4-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 65 67 71 73 72 69 64 57
LwA Outlet 80 67 69 73 75 74 71 66 59
LwA Surrounding 63 50 52 56 58 57 54 49 42
Measurement point: 1.79 m³/s @ 717 Pa

MUB 062 560D6-A2 IE2 MUB 062 560D6-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 56 58 63 64 64 60 55 47
LwA Outlet 71 58 60 65 66 66 62 57 49
LwA Surrounding 54 41 43 48 49 49 45 40 32
Measurement point: 1.31 m³/s @ 295 Pa
140 | Rectangular & Square Duct Fans
duct fans
Square

MUB 062 630D4-A2 IE2 MUB 062 630D4-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 73 75 79 81 80 77 72 65
LwA Outlet 88 75 77 81 83 82 79 74 67
LwA Surrounding 75 62 64 68 70 59 66 61 54
Measurement point: 2.3 m³/s @ 994 Pa

MUB 062 630D6-A2 IE2 MUB 062 630D6-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 60 62 67 68 68 64 59 51
LwA Outlet 75 62 64 69 70 70 66 61 53
LwA Surrounding 60 47 49 54 55 55 51 46 38
Measurement point: 1.66 m³/s @ 390 Pa
Rectangular & Square Duct Fans | 141

Q [m³/h] Q [m³/h]

duct fans
Square
0 2000 4000 6000 8000 10000 12000 14000 0 3000 6000 9000 12000
1200 1200

13956

13957
MUB 062 630DV MUB 062 630DV
1000 1000

800 800
Ps [Pa]

Ps [Pa]
600 600

400 400

200 200

1 2 3 4 5 1 2 3 4 5
0
0.5 1.5 2.5 3.5
Q [m³/s] Q [m³/s]

4000
4000 5
5

P [W]
P [W]

2000 3 2000 3

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 87 74 76 80 82 81 78 73 66
LwA Outlet 89 76 78 82 84 83 80 75 68
LwA Surrounding 76 63 65 69 71 70 67 62 55
Measurement point: 2.29 m³/s @ 773 Pa

MUB 100 630D4-L IE2


MUB 100 630D4-L IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 87 58 76 80 82 81 78 73 65
LwA Outlet 89 60 78 82 84 83 80 75 67
LwA Surrounding 81 52 70 74 76 75 72 66 59
Measurement point: 3.11 m³/s @ 990 Pa
142 | Rectangular & Square Duct Fans
duct fans
Square

MUB 100 710D6-A2 IE2


MUB 100 710D6-A2 IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 65 67 72 73 73 69 64 56
LwA Outlet 80 67 69 74 75 75 71 66 58
LwA Surrounding 66 53 55 60 61 61 57 52 44
Measurement point: 2.46 m³/s @ 521 Pa
Rectangular & Square Duct Fans | 143

Installation example

duct fans
Square

Panels can be exchanged for different outlet positions.


144 | Rectangular & Square Duct Fans

KDRE / KDRD Electrical


accessories
• Speed controllable
duct fans
Square

• Integral thermal contacts


• Can be installed in any position
• Maintenance-free and reliable
S-ET/STDT
KDRE/KDRD fans have external rotor motors and mixed flow impel- p. 373
lers. The KDRE/KDRD series is notable for its relatively high static
pressure and high level of efficiency. The casing is manufactured from
galvanized steel.
To protect the motor from overheating, the KDRE/KDRD fans have
integral thermal contacts with leads for connection to a TK triggering
device. RTRE p. 356
The fans can be installed in any position and are simple to couple
using DS flexible connections.

REU p. 356
Quick selection

REE p. 357

4466,1646, 3925, 584


586, 5182, 583

1 KDRE 45 1 KDRD 50
2 KDRE 50 2 KDRD 55
3 KDRE 55 3 KDRD 65
4 KDRD 70

RTRD/RTRDU
p. 357

1 2 3
1 2 3 4

Technical data
KDRE 45 KDRE 50 KDRD 50 KDRE 55 KDRD 55
Art. no. 1311 1313 1314 1315 1316
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 400 3~ 230 1~ 400 3~
Power W 325 442 462 861 789
Current A 1.55 1.94 0.962 4.10 1.52
Max. air flow m3/s 1.00 1.27 1.34 1.94 1.87
R.p.m. min-1 1387 1297 1397 1280 1315
Max. temp. of transported air °C 70 70 70 45 49
“ when speed controlled °C 70 70 70 45 40
Sound pressure level at 3 m dB(A) 45 52 54 51 55
Weight kg 22 32 27 40 38
Insulation class, motor F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor 8 10 – 16 –
Motor protection S-ET 10 S-ET 10 STDT 16 S-ET 10 STDT 16
Speed control, five-step Transformer RTRE 3 RTRE 5 RTRD 2 RTRE 5 RTRD 2
Speed control, five step high/low Transformer REU 3* REU 5* RTRDU 2 REU 5* RTRDU 2
Speed control, stepless Thyristor REE 2* REE 4* – – –
Wiring diagram p. 442-461 6 6 8 6 8
* + S-ET 10
Rectangular & Square Duct Fans | 145

Dimensions Ventilation
accessories

duct fans
Square
ø10(4x)

DSK p. 414

45
LDK p. 409

C A*
c/c
B FFS p. 409
* Inner dimension

A c/c B C
KDRE 45 447 470 492 400
KDRE/D 50 502 520 547 450
KDRE/D 55 550 573 595 485 RBK p. 410
KDRD 65 661 680 707 510

VBK p. 408

KDRD 65 KDRD 70
Art. no. 1318 6690
Voltage/Frequency V/50 Hz 400 3~ 400 3~
Power W 1250 2489
Current A 2.23 4.67
Max. air flow m3/s 2.72 4.12
R.p.m. min-1 1341 1383
Max. temp. of transported air °C 70 70
“ when speed controlled °C 56 69
Sound pressure level at 3 m dB(A) 53 62
Weight kg 48,6 58,5
Insulation class, motor F F
Enclosure class, motor IP 54 IP 54
Motor protection STDT 16 STDT 16
Speed control, five-step Transformer RTRD 4 RTRD 7
Speed control, five step high/low Transformer RTRDU 4 RTRDU 7
Speed control, stepless Thyristor – –
Wiring diagram p. 442-461 8 8
146 | Rectangular & Square Duct Fans

Performance
duct fans
Square

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 49 60 63 64 64 62 57 51 LwA Inlet 71 45 58 64 68 63 61 58 50
LwA Outlet 74 50 61 63 67 71 68 59 50 LwA Outlet 74 46 62 64 68 69 65 62 54
LwA Surrounding 53 33 40 48 46 47 43 36 32 LwA Surrounding 59 26 45 57 52 50 48 44 40
With LDK 45 With LDK 50
LwA Inlet 61 49 55 54 51 52 54 50 43 LwA Inlet 61 46 51 56 55 51 51 50 43
LwA Outlet 64 51 56 55 53 59 59 51 42 LwA Outlet 64 47 55 56 55 57 56 54 47
Measurement point: 0.602 m³/s @ 133 Pa Measurement point: 0.697 m³/s @ 187 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 59 65 69 71 68 65 58 50 LwA Inlet 75 58 62 68 70 70 68 61 55
LwA Outlet 79 57 67 69 71 75 71 63 54 LwA Outlet 80 58 65 69 73 76 72 64 57
LwA Surrounding 61 30 51 57 53 56 52 44 36 LwA Surrounding 59 43 48 57 46 49 44 40 34
With LDK 50 With LDK 55
LwA Inlet 66 59 58 61 58 56 56 50 42 LwA Inlet 65 58 53 59 57 58 57 51 46
LwA Outlet 69 57 61 61 58 63 62 55 47 LwA Outlet 69 58 55 60 59 64 62 55 49
Measurement point: 0.739 m³/s @ 219 Pa Measurement point: 0.972 m³/s @ 253 Pa
Rectangular & Square Duct Fans | 147

duct fans
Square
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 76 56 61 69 71 70 68 61 54 LwA Inlet 79 62 70 72 72 72 71 64 57
LwA Outlet 80 59 65 69 74 77 73 65 57 LwA Outlet 84 62 69 70 78 82 77 69 61
LwA Surrounding 62 57 48 59 51 50 47 44 44 LwA Surrounding 60 40 47 58 50 50 49 38 27
With LDK 55 With LDK 65
LwA Inlet 66 56 52 60 58 58 58 52 46 LwA Inlet 70 62 64 65 58 59 62 56 50
LwA Outlet 70 59 56 60 61 65 63 56 49 LwA Outlet 73 62 62 63 64 68 68 61 54
Measurement point: 0.944 m³/s @ 273 Pa Measurement point: 1.23 m³/s @ 345 Pa

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 84 75 74 77 77 78 76 69 65
LwA Outlet 89 74 76 79 82 85 80 73 67
LwA Surrounding 69 44 54 63 62 64 60 54 49
With LDK 70
LwA Inlet 77 75 69 70 58 54 53 54 55
LwA Outlet 78 74 71 72 63 61 57 58 57
Measurement point: 2.27 m³/s @ 405 Pa
148 | Rectangular & Square Duct Fans

NEW!
MUB/T EC Electrical
accessories
• EC-motors, high level of efficiency
duct fans
Square

• 100% speed controllable


• Up to 120°C medium temperature, continuous operation
• Pre-assembled isolator is standard
• Low sound level CO2RT
• Easy to maintain and reliable p. 368
• Motor outside the air stream
• Integrated motor protection

All MUB/T EC models have one potential-free terminal for error


message. All motors are suitable to be used for 50/60Hz. The input CXE p. 369
voltage for single phase units can vary between 200 and 277V.
Speed control by a 0-10V signal. Every motor has an output voltage
120°C of 10V for an external potentiometer or sensor.
All MUB/T EC fans have impellers with backward curved blades,
manufactured from aluminium. The MUB/T-EC fans are suitable for
medium temperatures up to 120°C continuously. The casing con-
REU p. 356
sists of an aluminium frame with fibreglass reinforced plastic cor-
ners and double skin, galvanized steel panels with a 20 mm mineral
wool insulation.
Panels are removable, allowing flexible ventilation solutions - the
air direction can easily be changed. With quick lock access door. The
MUB/T EC bottom panel is shaped as a grease tray and incorporates MTP p. 360
a pre-mounted 1” drain plug. An isolator switch is mounted on the
casing.

MTV p. 359

IR24-P
p. 368

EC-Vent
p. 365

Technical data
MUB/T 025 355EC 042 400EC 042 450EC 042 500EC 062 560EC
Art. no. 34546 34545 34491 34538 34539
Voltage/Frequency V/50/60 Hz 230 ~1 230 ~1 400 ~3 400 ~3 400 ~3
Power at shaft W 313 549 827 1536 2274
Current A 1.33 2.34 1.39 2.29 3.3
Max. air flow m3/s 0.83 1.21 1.74 2.26 3.36
R.p.m. min-1 1508 1512 1442 1504 1449
Max. temp. of transported air °C 120 120 120 120 120
Sound pressure level at 3 m dB(A) 42 44 47 49 52
Weight kg 29 51 53 75 109
Insulation class, motor B B B B F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 46 48 48 47 47
Rectangular & Square Duct Fans | 149

Dimensions Ventilation
accessories

duct fans
Square
A

FGV p. 413

SRKG p. 413

C
D

B
F
UGS p. 413

WSD p. 413
1 Zoll

MUB/T £A £B £C £D øE F
WSG p. 413
025 355EC 500 500 420 378 355 224
042 400EC 670 670 590 548 404 253
042 450EC 670 670 590 548 454 286
042 500EC 670 670 590 548 504 321
062 560EC 800 800 720 676 570 361
CCM p. 413

Quick selection CCMI


p. 414

1 MUB/T 025 355EC


2 MUB/T 042 400EC
3 MUB/T 042 450EC
4 MUB/T 042 500EC
5 MUB/T 042 560EC

1 2 3 4 5
150 | Rectangular & Square Duct Fans

Performance
Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 3500 0 1000 2000 3000 4000
400 500
duct fans

12063

12061
MUB/T 025 355EC MUB/T 042 400EC
Square

400
300

300
Ps [Pa]

Ps [Pa]
200

200

100
100

0 0
0 0.2 0.4 0.6 0.8 1 0 0.25 0.5 0.75 1 1.25
Q [m³/s]
Q [m³/s]
400 600
P [W]

400

P [W]
200
200

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 61 48 50 54 56 55 52 47 40 LwA Inlet 67 54 56 60 62 61 58 53 46
LwA Outlet 63 50 52 56 58 57 54 49 42 LwA Outlet 69 56 58 62 64 63 60 55 48
LwA Surrounding 55 42 44 48 50 49 46 41 34 LwA Surrounding 51 38 40 44 56 45 42 37 30
Measurement point: 0.46 m³/s @ 302 Pa Measurement point: 0.67 m³/s @ 423 Pa

Q [m³/h]
0 1000 2000 3000 4000 5000 6000 0 2000 4000 6000 8000
700 800

12062
12064

MUB/T 042 450EC MUB/T 042 500EC


600

600
500

400
Ps [Pa]

400
300

200
200

100

0 0
0 0.3 0.6 0.9 1.2 1.5 1.8 0 0.4 0.8 1.2 1.6 2 2.4
Q [m³/s]
2000
1000
P [W]

500 1000

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 56 58 62 64 63 60 45 48 LwA Inlet 71 58 60 64 66 65 62 57 50
LwA Outlet 71 58 60 64 66 65 62 57 50 LwA Outlet 73 60 62 66 68 67 64 59 52
LwA Surrounding 54 41 43 47 49 48 45 40 33 LwA Surrounding 56 43 45 49 51 50 47 42 35
Measurement point: 0.95 m³/s @ 455 Pa Measurement point: 1.25 m³/s @ 628 Pa
Rectangular & Square Duct Fans | 151

duct fans
Square
0 2500 5000 7500 10000 12500
1000

12060
MUB/T 062 560EC
800

600

400

200

0
0 0.5 1 1.5 2 2.5 3 3.5

2000

1000

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 62 64 68 70 69 66 61 54
LwA Outlet 77 64 66 70 72 71 68 63 56
LwA Surrounding 60 47 49 53 55 54 51 46 39
Measurement point: 1.8 m³/s @ 701 Pa
152 | Rectangular & Square Duct Fans

MUB/T Electrical
accessories
• Up to 120°C medium temperature, continuous operation
duct fans
Square

• Pre-assembled isolator is standard


• Low sound level
• Easy to maintain and reliable FRQ p. 361
• Speed-controllable via frequency converter
• Motor outside the air stream

All MUB/T fans have impellers with backward curved blades,


manufactured from aluminium, and IEC standard motors outside
the air stream with efficiency class IE2 for all 400V three phase STDT p. 373
motors from 0.75 kW. The MUB/T fans are suitable for medium
temperatures up to 120°C continuously. Motor protection by cold
IE2
2009/640/EG
conductors (PTC) or thermal contacts (TK), to be connected to an
external PTC/TK triggering device.
120°C
The casing consists of an aluminium frame with fibreglass re-
inforced plastic corners and double skin, galvanized steel panels RTRE p. 356
Note: Outlet spigot to be ordered with a 20 mm mineral wool insulation. Panels are removable, al-
as an accessory. lowing flexible ventilation solutions - the air direction can easily
be changed. With quick lock access door. The MUB bottom panel
is shaped as a grease tray and incorporates a pre-mounted 1”
drain plug. An isolator switch is mounted on the casing.
REU p. 356
Quick selection

9823, 10950, 9821


11976, 11977, 9826, 9859, 9824, 9825

1 MUB/T 025 355DV 1 MUB/T 042 500D4-IE2


2 MUB/T 025 355E4
2 MUB/T 062 560D4-IE2
3 MUB/T 042 400DV
3 MUB/T 062 630D4-IE2 RTRD/RTRDU
4 MUB/T 042 400E4
5 MUB/T 042 450D4-IE2
p. 357
6 MUB/T 042 450E4

U-EK230E
p. 374
1 3 5

2 4 6
1 2 3

Technical data
MUB/T 025 355DV 025 355E4 042 400DV 042 400E4 042 450D4-IE2 042 450E4
Art. no. 34784 34783 33655 33656 33657 33658
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~
Power at shaft W 280 315 528 456 924 1014
Current A 1.3 1.47 1.4 2.1 1.78 5.3
Max. air flow m3/s 0.80 0.76 1.13 1.11 1.72 1.68
R.p.m. min-1 1460 1400 1370 1370 1400 1430
Max. temp. of transported air °C 120 120 120 120 120 120
Sound pressure level at 3 m dB(A) 45 46 47 47 49 50
Weight kg 30 29 49 49 57 53
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 55 IP 54
Capacitor µF – 8 – 12 – 30
Motor protection STDT 16 S-ET 10 STDT 16 S-ET 10 U-EK 230E S-ET 10
Speed control, five step RTRD 2 RTRE 3 RTRD 2 RTRE 3 – RTRE 7
Speed control, frequency converter* FRQ - – – FRQ –
Wiring diagram p. 442-461 17c 21 17c 21 17a 21

* Frequency converters are available with or without sine filter, and stepless or with five step switch (see page 361)
Rectangular & Square Duct Fans | 153

Dimensions Ventilation
accessories

duct fans
Square
A

MUB/T £A £B £C £D øE F
FGV p. 413
025 355 500 500 420 378 355 224
042 400 670 670 590 548 404 253
042 450 670 670 590 548 454 286
042 500 670 670 590 548 504 321

D

C

B
øF
øE
062 560 800 800 720 678 564 361
SRKG p. 413
062 630 800 800 720 678 635 407

UGS p. 413
1 inch

WSD p. 413

WSG p. 413

CCM p. 413

CCMI
p. 414

MUB/T 042 500D4-IE2 062 560D4-IE2 062 630D4-IE2


Art. no. 33622 33659 33660
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~
Power at shaft W 1373 2415 4498
Current A 2.87 4.2 8.12
Max. air flow m3/s 2.23 3.25 4.12
R.p.m. min-1 1441 1445 1450
Max. temp. of transported air °C 120 120 120
Sound pressure level at 3 m dB(A) 53 55 67
Weight kg 70 99 111
Insulation class, motor F F F
Enclosure class, motor IP 55 IP 55 IP 55
Capacitor µF – – –
Motor protection U-EK 230E U-EK 230E U-EK 230E
Speed control, five step – – –
Speed control, frequency converter* FRQ FRQ FRQ
Wiring diagram p. 442-461 17a 17a 17b

* Frequency converters are available with or without sine filter, and stepless or with five step switch (see page 361)
154 | Rectangular & Square Duct Fans

Performance
Q [m³/h] Q [m³/h]
0 1000 2000 3000 0 500 1000 1500 2000 2500
400 400

11976
11977
duct fans

MUB/T 025 355DV MUB/T 025 355E4


Square

300 300

Ps [Pa]
Ps [Pa]

200 200

100 100

0 0
0 0.2 0.4 0.6 0.8 0 0.2 0.4 0.6 0.8
Q [m³/s] Q [m³/s]

400
300
P [W]

P [W]
200 200

0 100

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 55 57 61 63 62 59 54 47 LwA Inlet 68 55 57 61 63 62 59 54 47
LwA Outlet 70 57 59 63 65 64 61 56 49 LwA Outlet 70 57 59 63 65 64 61 56 49
LwA Surrounding 62 49 51 55 57 56 53 48 41 LwA Surrounding 62 49 51 55 57 56 53 48 41
Measurement point: 0.4 m³/s @ 280 Pa Measurement point: 0.42 m³/s @ 264 Pa

MUB/T 042 400DV MUB/T 042 400E4

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 57 59 63 65 64 61 56 51 LwA Inlet 70 57 59 63 65 64 61 56 49
LwA Outlet 72 59 61 65 67 66 63 58 51 LwA Outlet 72 59 61 65 67 66 63 58 51
LwA Surrounding 54 41 43 47 49 48 45 40 33 LwA Surrounding 54 41 43 47 59 48 45 40 33
Measurement point: 0.68 m³/s @ 323 Pa Measurement point: 0.61 m³/s @ 311 Pa
Rectangular & Square Duct Fans | 155

duct fans
Square
MUB/T 042 450D4-IE2 MUB/T 042 450E4

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 58 60 64 66 65 62 47 50 LwA Inlet 72 59 61 65 67 66 63 48 51
LwA Outlet 73 60 62 66 68 67 64 59 52 LwA Outlet 74 61 63 67 69 68 65 60 53
LwA Surrounding 56 43 45 49 51 50 47 42 35 LwA Surrounding 57 44 46 50 52 51 48 43 36
Measurement point: 0.945 m³/s @ 475 Pa Measurement point: 0.922 m³/s @ 440 Pa

MUB/T 042 500D4-IE2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 62 64 68 70 69 66 61 54 LwA Inlet 78 65 67 71 73 72 69 64 57
LwA Outlet 77 64 66 70 72 71 68 63 56 LwA Outlet 80 67 69 73 75 74 71 66 59
LwA Surrounding 60 47 49 53 55 54 51 46 39 LwA Surrounding 63 50 51 56 58 57 54 49 42
Measurement point: 1.23 m³/s @ 569 Pa Measurement point: 1.79 m³/s @ 732 Pa
156 | Rectangular & Square Duct Fans
duct fans
Square

MUB/T 062 630D4-IE2

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 73 75 79 81 80 77 72 65
LwA Outlet 88 75 77 81 83 82 79 74 67
LwA Surrounding 75 62 64 68 70 69 66 61 54
Measurement point: 2.47 m³/s @ 896 Pa
Rectangular & Square Duct Fans | 157

duct fansfans
Rectangular
Square
Square duct
Reference: Matrix, Pune, India
North side

Type of Building: Commercial office building


Products/Solution: Jet Fans, Axial Fans, Roof Fans, Inline Fans (K)
Motorized fire dampers with actuators, grilles, louvres, diffusers, VCD’s.
South side
158 | Roof Fans
Roof fans

Roof Fans
IE2
2009/640/EG
120°C 200°C

DHS DVS/DVSI DVS/DVSI


Example of an installation. Also Example of an installation. Also Example of an installation. Also
possible with DVS, DVN and DVC. possible with DHS, DVN and DVC. possible with DHS, DVN and DVC.

1 7 7

8 10
2

5 11

2
6
3
5
9

4
9

General Systemair range Motors


Systemair roof fans have been developed Systemair roof fans are available for vertical Systemair roof fans DVS/DVSI/DHS and
for the use in effective exhaust air systems. discharge (ranges DVS, DVSI, DVC, DVN and TFSR/TFSK are equipped with external rotor
Ranges DVS/DVSI/DHS/DVN/DVNI/DVC DVNI up to size 900, DVV and DVVI) and for motors, speed controllable by voltage. DVN
are equipped with a sea water resistant horizontal discharge (ranges TFSR/TFSK and and DVV are driven by IEC standard motors
aluminium casing. The integrated bird DHS up to size 710). The vertical discharge in efficiency class IE2 as per guideline
screen is manufactured from galvanized units are also available with sound insulated 2009/640/EC. DVC is equipped with
and powder coated steel. The impellers casing, having a 50 mm insulation (density electronically commutated EC-motor, either
are manufactured either from compound 60 kg/m3). with automatic speed control by pressure
material or from aluminium. (integrated pressure sensor) or with manual
All of Systemair roof fans are equipped speed control by an external 0-10V signal.
Range TFSR/TFSK has a casing with self-cleaning impellers with backward Most of the roof fans are equipped with
manufactured from galvanized steel, curved blades. A comprehensive range of thermal contacts or cold conductors for
powder coated in black. The units are easy to install accessories is available. motor protection. DVS/DHS/DVN from size
supplied with cord and plug. 355 have to be connected to an external
PTC/TK triggering device.
Roof Fans | 159

Roof fans
DVN/DVNI 1 DHS Roof fan
Example of an installation. Also
possible with DHS, DVN and DVC. 2 VKS Automatic shutter

3 SSD Socket silencer


12
4 ASK Connection box

5 ASS Flexible connection


10
6 ASF Inlet flange
11
2 7 DVS/DVSI Roof fan
8 8 VKM Motor driven shutter

9 FDS Flat roof socket


3
9 10 FTG Tilting device

11 TDA Adapter frame


4
12 DVN/DVNI Roof fan
2

TFSR/TFSK EC 160 DVC/DVCI 170 DVN/DVNI IE2


188
2009/640/EG
120°C

Roof fan with Roof fan with Roof fan, vertical outlet,
EC-motor EC-motor up to 120°C

TFSR/TFSK 162 DHS/DVS/DVSI sileo 176 DVV 194


IE2
2009/640/EG
120°C

Roof fan, horizontal Roof fan, Roof fan, vertical outlet,


outlet low noise level up to 120°C

DHA sileo 166 DHS/DVS/DVSI 184 ZRS 198


200°C

Supply air roof fan Roof fan Flue gas roof fan, vertical
outlet, up to 120°C
160 | Roof Fans

TFSR EC / TFSK EC Electrical


accessories
• H igh efficiency EC-motors
• 100% speed controllable
• Swing-out

The TFSR EC and TFSK EC roof mounted fans are driven by EC mo- MTP 10
p. 359
tors and intended for use as extract fans in smaller premises such as
Roof fans

self contained flats and apartments as well as storage areas, smaller


work-rooms etc. EC-technology is intelligent technology, using inte-
gral electronic control to ensure that the motor always runs at opti-
mal load and guarantees an effective utilisation of energy. CXE/AV
The fans are delivered with a pre-wired potentiometer (0-10V) p. 369
that allows you to easily find the desired working point. The isola-
tion switch is integrated and there are several alternative roof curbs
available as accessories. The tilting mechanism simplifies cleaning
and maintenance. To protect the motor from overheating, the fans
have integrated thermal contacts with automatic reset. EC-Vent
TFSR EC comes with circular base plate whilst the TFSK EC is pro- p. 365
vided with a square base frame. The horizontal discharge creates
smaller internal pressure losses and prevents accumulation of ice on
the roof. The protection guard prevents unintentional contact with
the impeller. Both models are delivered with a connection box.
TFSR 125-160 are delivered with a ø160 spigot and TFSR 200-315
with a ø200.

Technical data
TFSR/TFSK 160 EC 200 EC
Art. no 1226/1223 1227/1224
Voltage/Frequency V/50/60 Hz 230 1~ 230 1~
Power W 81.5 74.6
Current A 0.64 0.587
Max. air flow m3/s 0.161 0.216
R.p.m. min-1 3162 2501
Max. temp. of transported air °C 45 45
“ when speed controlled °C 45 45
Sound pressure level at 10 m dB(A) 43 43
Weight kg 4.3/4.7 5.4/6.2
Insulation class, motor B B
Enclosure class, motor IP 44 IP 44
Speed control, electronic MTP 10 MTP 10
Wiring diagram p. 442-461 41 41
Roof Fans | 161

Dimensions Ventilation
accessories

øC øC

TOB p. 416

A
B
A
B

Roof fans
HC
E LDC p. 390

36
øD

c/c F
ø9(4x)

RSK p. 388

TFSR A B C D HC TFSK A B øC £E c/cF


160 EC 147 172 334 380 205 160 EC 147 172 334 421 330
200 EC 150 187 364 439 250 200 EC 150 187 364 421 330
HC= Hole diameter for fixing, ø6x4

Performance

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 53 72 70 70 70 66 62 50 LwA Inlet 74 48 65 65 68 69 62 58 47
LwA Outlet 74 38 58 57 68 71 68 63 54 LwA Outlet 74 27 59 62 68 69 68 61 49
Measurement point: 0.0806 m³/s @ 392 Pa Measurement point: 0.108 m³/s @ 274 Pa
162 | Roof Fans

TFSR / TFSK Electrical


accessories
The TFSR/TFSK roof fans are fitted with a single-inlet centrifugal fan
with backward curved blades and external rotor motors. The motors
can be tilted outwards to facilitate inspection and service. They have
integral on/off isolator and are supplied with 1 m cable.
TFSR has a circular base plate. Cable for fast connection to the RE p. 356
mains e.g. via the connection box on the roof curb TOB or TOS. TFSR
Roof fans

125-160 are delivered with a ø160 spigot and TFSR 200-315 with a
ø200.
TFSK has a square base frame, the cable is easily connected to
our standard roof curbs TG, FDS and SSD. These fans are suitable for
exhaust-air ventilation systems, e.g. single and multiple dwellings, REU p. 356
offices and day nurseries. To protect the motors from overheating,
• Swing-out all motors have an integral thermal contact with automatic reset.
The casings are manufactured from galvanized steel, with powder
• Speed-controllable
coating in black colour.
• Easy to install
REE p. 357
• Reliable

Quick selection
6526, 6558, 6427, 6424, 7696, 7691

1 TFSK 125M
2 TFSK 125XL
3 TFSK 160
4 TFSR 200
5 TFSR 315M
6 TFSR 315L

1 2 3 4 5 6

Technical data
TFSR/TFSK 125 M 125 XL 160 200 315 M 315 L
Art. no. 1330/1344 1332/1346 1333/1348 1334/1349 19542/19537 19539*/19534*
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 24.8 53.9 58.3 108 199 329
Current A 0.13 0.26 0.26 0.47 0.88 1.43
Max. air flow m3/s 0.086 0.106 0.121 0.208 0.333 0.444
R.p.m. min-1 1965 2531 2461 2537 2505 2401
Max. temp. of transported air °C 70 40 70 62 67 42
“ when speed controlled °C 70 40 70 62 60 38
Sound pressure level at 10 m dB(A) 23 33 36 40 43 53
Weight kg 2.5 2.5/3.3 3.3 4.2 8.0/9.7 9.1/10.7
Insulation class, motor B F B B F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF 1.5 1.5 2 3 5 8
Speed control, five step Transf. RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5 RE 1.5
Speed control, five step high/low Transf. REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5 REU 1.5
Speed control, stepless Thyristor REE 1 REE 1 REE 1 REE 1 REE 1 REE 2
Wiring diagram p. 442-461 29 29 29 29 29 29
* Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
Roof Fans | 163

Dimensions Ventilation
accessories
øG (4x)
c/c F

øC øC

TOB p. 416
A

A
B

Roof fans
36
HC E
øD TG p. 417

øG (4x)
c/c F

øC LDC p. 390
A
B

36 RSK p. 388

E

FDS p. 420

TFSR A B C D HC TFSK A B øC £E c/cF øG


125 M/XL 119 144 284 315 205 125 M/XL 119 144 284 321 245 9
160 120 145 334 380 205 160 120 145 334 421 330 9
200 123 160 364 439 250 200 123 160 364 421 330 9 SSD p. 419
315 M/L 160 206 404 485 250 315 M/L 160 206 404 521 450 11
HC= Hole diameter for fixing, ø6x4
164 | Roof Fans

Performance
Roof fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 58 38 50 52 51 50 49 32 23 LwA Inlet 68 47 60 63 58 62 57 49 37
LwA Outlet 54 20 40 45 47 50 49 37 26 LwA Outlet 64 27 46 51 53 60 60 50 37
Measurement point: 0.0474 m³/s @ 80.2 Pa Measurement point: 0.0589 m³/s @ 151 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 50 62 62 61 61 58 49 38 LwA Inlet 71 50 62 64 64 66 63 56 47
LwA Outlet 67 26 53 55 58 62 62 54 48 LwA Outlet 71 31 52 56 61 67 67 61 49
Measurement point: 0.0606 m³/s @ 219 Pa Measurement point: 0.105 m³/s @ 280 Pa
Roof Fans | 165

Q [m³/h]
0 200 400 600 800 1000 1200 1400
800

12564/12565
700
TFSR/TFSK 315 M

600

500
72

Roof fans
Ps [Pa]

400

300
67 73

200
60
67

100 57 60
51 56
52
1 2 3 4 5
0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4
q [m³/s]

300

200 5
P [W]

100 2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 50 58 60 65 65 64 60 56 LwA Inlet 78 51 70 68 75 71 67 63 54
LwA Outlet 74 40 52 61 68 70 68 59 55 LwA Outlet 84 37 62 65 82 79 73 64 57
Measurement point: 0.167 m³/s @ 439 Pa Measurement point: 0.219 m³/s @ 454 Pa
166 | Roof Fans

DHA sileo Electrical


accessories
• Axial roof fan for supply air
• Casing and base frame manufactured from galvanized steel, pow-
der coated RAL 7010; cowl manufactured from seawater resistant
aluminium. S-ET/STDT
• With external rotor motors, speed controllable by voltage reduc- p. 373
Roof fans

tion. Three phase version can be switched between D/Y connec-


tion for two speeds.
• Motor protection via integral thermal contacts with external leads
for connection to a motor protection switch, for example Systemair
RTRE p. 356
unit S-ET.
• Size 400: Impeller blades with bionic shape are manufactured
from high efficiency composite material.
• Size 500-630: Impeller blades with bionic shape are manufactured
from pressure die cast aluminum. REU p. 356

Quick selection
qv [m³/h] RTRD p. 357
0 5000 10000 15000 20000
160
Ps [Pa]

1 DHA sileo 400E4


140 2 DHA sileo 400DV
3 DHA sileo 500E4
120
4 DHA sileo 500DV RTRDU p. 357
5 DHA sileo 630E6/DS
6
6 DHA sileo 630DV
100

80
2
3
4
60
REE p. 357
1

40
5
20

0 S-DT2 SKT
0 1 2 3 4 5 6 p. 381
qv [m³/s]

Technical data
DHA sileo 400E4 400DV 500E4 500DV 630E6 630DS 630DV
Art. no. 34500 34501 34502 34503 34504 34505 34506
Voltage/Frequency V/50/60 Hz 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 400 3~
Power W 240 230 750 770 730 630 2400
Current A 1.1 0.44 3.35 1.7 3.4 1.25 4.75
Max. air flow m3/s 1.0 1.0 2.3 2.4 2.9 2.9 4.9
R.p.m. min-1 1375 1370 1230 1300 910 903 1320
Max. temp. of transported air °C 65 70 70 70 70 70 65
Sound pressure level at 10 m dB(A) 41 41 45 46 43 43 56
Weight kg 18 18 35 35 51 51 71
Insulation class, motor F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP54
Capacitor µF 5 – 16 – 16 – –
Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 S-ET 10 STDT 16 STDT 16
Speed control, five step Transformer RTRE 1.5 RTRD 2 RTRE 5 RTRD 2 RTRE 5 RTRD 2 RTRD 7
Speed control, five step high/low Transformer REU 1.5* RTRDU 2 REU 5* RTRDU 2 REU 5* RTRDU 2 RTRDU 7
Speed control, two step, 400V D/Y – S-DT2 SKT – S-DT2 SKT – S-DT2 SKT S-DT2 SKT
Speed control, stepless Thyristor REE 2* – REE 4* – – – –
Wiring diagram p. 442-461 6a 18b 6a 18b 6a 18b 18b

*) + S-ET 10
Roof Fans | 167

Dimensions Ventilation
accessories
DHA 400
ø830
FDS p. 420
225
398,95

Roof fans
216,5
4x d10

450
595

DHA 500/630
C
B

DHA £A B C D £E G
4xG
500 1100 434 240 535 665* 4x⌀12
630 1282 481.5 240 750 939* 4x⌀14
D * inside
E

A
168 | Roof Fans

Performance

Q [m³/h] Q [m³/h]
0 1000 2000 3000 0 1000 2000 3000
80 100

12672/12673

11018/11022
DHA sileo 400E4 DHA sileo 400DV

60 78 75
Roof fans

83
Ps [Pa]

Ps [Pa]
40 50
76 77

79

75
7
75 82
20 73 25
69
77
73
68 72
64
64 68 58
54
64
1 2 3 4 5 1 2 3 4
0 0
0 0.25 0.5 0.75 1 0 0.25 0.5 0.75 1
Q [m³/s Q [m³/s

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 40 62 65 65 66 63 58 50 LwA Inlet 72 42 64 64 65 66 63 58 50
LwA Outlet 75 38 56 63 69 70 68 62 54 LwA Outlet 77 49 61 70 72 71 68 62 53
Measurement point: 0.727 m³/s @ 60.7 Pa Measurement point: 0.722 m³/s @ 67.5 Pa

Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 10000 0 2000 4000 6000 8000 10000
100 100
11172/11173

11135/11136
89

DHA sileo 500E4 DHA sileo 500DV


83

75 75
Ps [Pa]

Ps [Pa]

85
50 50
78 81
84

85

75 79
76 83
25 25
75 72
69 63
69
67 64
67
1 2 3 4 5 1 2 3 4 5
0 0
0 1 2 3 0 0.5 1 1.5 2 2.5 3
Q [m³/s Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 49 68 73 68 69 65 61 56 LwA Inlet 77 44 70 68 70 70 66 62 55
LwA Outlet 77 47 64 68 72 72 69 65 61 LwA Outlet 83 57 70 74 78 77 74 69 62
Measurement point: 1.47 m³/s @ 86.5 Pa Measurement point: 1.88 m³/s @ 96.3 Pa
Roof Fans | 169

Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 10000 0 2000 4000 6000 8000 10000
60 60

12455/12456
12817/12818
DHA sileo 630E6 83 DHA sileo 630DS
79 84
50 50

Roof fans
40 40 81
85
86
Ps [Pa]

Ps [Pa]
30 30
81 81
75 78

20 20
78 73 81
71
72
10 64
10 76
65

64 69
1 2 3 4 5 1 2 3 4 5
0 0
0 0.5 1 1.5 2 2.5 3 0 1 2 3
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 47 63 68 69 68 65 62 57 LwA Inlet 74 43 62 67 68 68 65 61 55
LwA Outlet 78 47 61 68 73 72 69 66 61 LwA Outlet 78 51 62 69 72 72 71 66 61
Measurement point: 2.39 m³/s @ 51.8 Pa Measurement point: 2.4 m³/s @ 50.2 Pa

Q [m³/h]
0 5000 10000 15000 20000
160
12811/13063

140 DHA sileo 630DV


94
120
87
100
Ps [Pa]

80 83

88
60
83
82
40
81

69
20 70

1 2 3 4 5
0
0 1 2 3 4 5 6
Q [m³/s]

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 87 55 77 77 80 83 79 73 65
LwA Outlet 90 55 75 79 84 86 83 77 70
Measurement point: 3.97 m³/s @ 148 Pa
170 | Roof Fans

DVC / DVCI Electrical


accessories
The DVC roof fans are driven by EC-external rotor motors, so
called energy saving motors with high efficiency. The input volt-
age for single phase units can vary between 200 and 277V, for
three phase units between 380 and 480V. All motors are suitable
REV p. 380
for 50Hz and 60Hz and from size 355 up to 630 suspended on
effective vibration dampers.
Roof fans

Motor protection is integrated in the electronics of the motor,


no additional external PTC/TK triggering device is needed. The
DVC-P versions have integrated pressure sensors and the elec-
tronics are programmed for a pressure constant operation. Two MTP 10
potentiometers in the electronics allow for 2 set values (day/ p. 359
night), one additional contact for an external setting.
• 100% speed controllable Casing from seawater-resistant aluminum, base frame galva-
• Integrated motor protection nized steel. DVCI have 50 mm mineral wool insulation for low
• Low noise level noise level.
Backward curved impellers manufactured from polyamide PA MTV 1/010
• Safe and maintenance free operation p. 359
6 for size 190 and 315. From 355 up to 630 impellers manufac-
• Energy-saving tured from seawater resistant aluminium.

EC-Vent
p. 365
Quick selection
6371, 5835, 5828, 5837, 7231

5966, 5969, 5977, 5974


1 DVC/DVCI 225 1 DVC/DVCI 450
2 DVC/DVCI 315 2 DVC/DVCI 500
3 DVC/DVCI 355 3 DVC/DVCI 560
4 DVC/DVCI 400 4 DVC/DVCI 630
5 DVC/DVCI 450 PK/SK

1 2 3 4 5 1 2 3 4

Technical data
DVC/DVCI 190-S 225-P/225-S 315-P/315-S 355-P/355-S 400-P/400-S 450-PK/450-SK
Art. no. DVC-P/DVC-S 32569 30690/30667 30634/30619 30635/30620 30682/30622 31327/31427
Art. no. DVC-P+REV/DVC-S +REV 33095 30691/30725 30684/30585 30692/30621 30685/30623 –
Art. no. DVCI-P/DVCI-S 33034 30701/30693 30702/30694 30703/30695 30704/30696 33195/32744
Art. no. DVCI-P+REV/DVCI-S +REV - 30717/30709 30718/30710 30719/30711 30720/30712 –
Voltage/Frequency V/50/60 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Fan power consumption (P1) W 87.8 166 173 378 381 614
Current A 0.65 1.17 1.18 2.31 2.30 2.79
Max. air flow m3/s 0.197 0.261 0.546 0.918 1.00 1.43
R.p.m. min-1 3114 3278 1867 1657 1348 1300
Max. temp. of transported air °C 60 60 60 60 60 60
Sound pressure level at 4 m/10 m, DVC dB(A) 58/51 58/51 47/39 50/42 49/41 53/45
Sound pressure level at 4 m/10 m, DVCI dB(A) 58/51 54/46 41/33 46/38 43/35 40/32
Weight, DVC/DVCI kg 7.5/12 9.5/14 13/18 21/27.5 22/31 35/41
Insulation class, motor B B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 54
Speed control, electronic MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10
Wiring diagram p. 442-461 23a 23b 23b 23b 23b 27
Roof Fans | 171

Dimensions Ventilation
accessories
A F

B G M20x1,5

H
SSD p. 419

Roof fans
G
C
øD
øI(4x)
FDS p. 420
øD
E

DVC/DVCI-S £A £B C øD £E £F G H øI ASK p. 418


190-225 370/497 295 170/179 213 335 245 105 6xM6 10(4x)
315 560/690 470 330/369 285 435 330 146 6xM6 10(4x)
355-400 720/874 618 390/439 438 595 450 200 6xM6 10(4x)
450-500 900/968 730/748 465/479 438 665 535 237 6xM8 12(4x) VKS p. 427
560-630 1150/1315 960 560/600 605 939 750 293 8xM8 14(4x)

C
A ASS p. 415
F
B G

M20x1.5

ASF p. 415
H
G
D

I
E

DVC/DVCI-P £A £B £C D £E £F G H øK øI
315 470 340 560/690 392.5 435 330 146 6xM6 285 10(4x)
355-400 618 420 720/874 454 595 450 200 6xM8 438 12(4x)
450-500 730/748 560 900/968 516 665 535 237 6xM8 438 12(4x)
560-630 960/988 740 1150/1315 565 939 750 293 6xM8 605 14(4x)

DVC/DVCI 450-P/450-S 500-P/500-S 560-P/560-S 630-P/630-S


Art no. DVC-P/DVC-S 30683/30626 30679/30628 30680/30630 30681/30632
Art no. DVC-P + REV/DVC-S + REV 30686/30627 30687/30629 30688/30631 30689/30633
Art no. DVCI-P/DVCI-S 30705/30697 30706/30698 30707/30699 30708/30700
Art no. DVCI-P + REV/DVCI-S + REV 30721/30713 30722/30714 30723/30715 30724/30716
Voltage/Frequency V/50/60 Hz 400 3~ 400 3~ 400 3~ 400 3~
Power W 1048 984 1873 2444
Current A 1.79 1.66 2.88 3.72
Max air flow m3/s 1.70 1.84 2.99 3.59
R.p.m. min-1 1558 1339 1359 1209
Max temp. of transported air °C 60 60 60 60
Sound pressure level at 4/10 m, DVC dB(A) 56/48 55/47 63/55 64/56
Sound pressure level at 4/10 m, DVCI dB(A) 50/42 51/43 55/47 57/49
Weight, DVC/DVCI kg 35/41 49/54 72/80 80/90
Insulation class, motor B B F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54
Speed control, electronic MTP 10 MTP 10 MTP 10 MTP 10
Wiring diagram p. 442-461 27 27 27 27
172 | Roof Fans

Performance

DVC/DVCI 190 DVC/DVCI 225


Roof fans

----- = only S-version


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
DVC 63 125 250 500 1k 2k 4k 8k DVC 63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 44 58 64 74 72 72 70 60 LwA Inlet 79 46 58 64 75 73 72 70 61
LwA Outlet 82 45 58 62 77 74 77 73 63 LwA Outlet 83 47 58 63 77 75 78 73 64
Measuring point: 0.133 m³/s @ 448 Pa Measuring point: 0.156 m³/s @ 387 Pa
DVCI DVCI
LwA Inlet 78 43 57 64 72 72 71 70 61 LwA Inlet 78 44 57 64 72 72 71 70 61
LwA Outlet 77 43 57 62 70 71 72 66 59 LwA Outlet 77 44 57 62 70 71 72 66 60
Measuring point: 0.133 m³/s @ 457 Pa Measuring point: 0.144 m³/s @ 427 Pa

DVC/DVCI 315 DVC/DVCI 355

----- = only S-version


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
DVC 63 125 250 500 1k 2k 4k 8k DVC 63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 41 56 59 64 59 56 55 49 LwA Inlet 71 37 65 62 65 63 62 60 56
LwA Outlet 70 42 57 60 67 64 60 57 49 LwA Outlet 73 38 60 66 68 67 65 62 56
Measurement point: 0.3 m³/s @ 226 Pa Measurement point: 0.505 m³/s @ 401 Pa
DVCI DVCI
LwA Inlet 67 38 53 59 63 60 55 51 49 LwA Inlet 72 38 61 64 68 62 64 59 57
LwA Outlet 64 37 53 56 60 59 52 43 41 LwA Outlet 69 41 58 61 66 62 60 53 48
Measurement point: 0.313 m³/s @ 229 Pa Measurement point: 0.572 m³/s @ 356 Pa
Roof Fans | 173

DVC/DVCI 450-PK/-SK
DVC/DVCI 400

Roof fans
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
DVC 63 125 250 500 1k 2k 4k 8k DVC 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 37 55 65 64 58 58 59 56 LwA Inlet 74 61 63 67 69 68 65 60 53
LwA Outlet 70 37 52 64 64 62 61 61 55 LwA Outlet 76 63 65 69 71 70 67 62 55
Measurement point: 0.55 m³/s @ 335 Pa Measurement point: 0.56 m³/s @ 450 Pa
DVCI DVCI
LwA Inlet 71 43 62 64 66 61 60 57 55 LwA Inlet 74 46 62 67 70 62 63 66 58
LwA Outlet 66 47 59 60 61 59 55 51 47 LwA Outlet 63 38 54 58 58 56 51 49 36
Measurement point: 0.561 m³/s @ 324 Pa Measurement point: 0.875 m³/s @ 381 Pa

DVC/DVCI 450 DVC/DVCI 500

----- = only S-version ----- = only S-version


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
DVC 63 125 250 500 1k 2k 4k 8k DVC 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 43 63 70 70 65 67 71 69 LwA Inlet 78 41 65 75 70 66 66 64 61
LwA Outlet 79 47 64 71 73 70 69 71 68 LwA Outlet 78 43 64 72 74 70 70 67 62
Measurement point: 1.02 m³/s @ 562 Pa Measurement point: 1.1 m³/s @ 464 Pa
DVCI DVCI
LwA Inlet 78 48 70 75 71 67 67 64 64 LwA Inlet 77 46 67 74 70 67 66 64 61
LwA Outlet 73 52 64 67 67 67 63 59 57 LwA Outlet 74 47 65 70 67 65 62 58 55
Measurement point: 1.02 m³/s @ 560 Pa Measurement point: 1.12 m³/s @ 482 Pa
174 | Roof Fans

DVC/DVCI 560 DVC/DVCI 630


Roof fans

----- = only S-version ----- = only S-version


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
DVC 63 125 250 500 1k 2k 4k 8k DVC 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 49 71 72 74 70 75 77 69 LwA Inlet 83 47 75 79 75 70 71 74 67
LwA Outlet 87 54 75 79 80 78 78 80 71 LwA Outlet 87 52 78 78 81 78 79 81 70
Messbedingungen: 1.8 m³/s @ 586 Pa Messbedingungen: 2.15 m³/s @ 653 Pa
DVCI DVCI
LwA Inlet 84 55 75 77 73 74 77 78 74 LwA Inlet 86 53 76 84 75 73 73 76 67
LwA Outlet 79 56 69 71 71 71 71 71 64 LwA Outlet 80 54 74 75 72 71 67 68 62
Measurement point: 1.79 m³/s @ 611 Pa Measurement point: 2.0 m³/s @ 656 Pa
Roof Fans | 175

Sileo version of roof fans DHS, DVS, DVSI


A completely new generation of modern Systemair roof fans which were developed and built con-
sistently according to the company‘s set target: low noise level, high performance. Especially suited
to all uses and areas of application sensitive to noise. You can see and hear the result: a reduction in
sound of up to 50 % at the same system performance and an increased level of efficiency com-
pared to its predecessors.

Roof fans
176 | Roof Fans

DHS sileo / DVS sileo / DVSI sileo Electrical


accessories
DHS • High efficiency
• Speed-controllable
• Integral thermal contacts
• Excellent sound level
S-ET/STDT
• Extensive range of accessories p. 373

Roof fans

Maintenance-free and reliable

The DVS/DHS/DVSI sileo is well suited for applications requiring high


DVS air volumes at medium pressure and very low noise levels. These
models have 3D profiled impellers with backward curved blades and RTRE p. 356
external rotor motors.
All motors are speed controllable by voltage. For speed controlling
of the DVS/DHS/DVSI sileo roof fans with a frequency converter, an
all pole sine filter is required. The motors are suspended on effective
DVSI
vibration dampers.
RTRD/RTRDU
p. 357
DVS/DHS/DVSI sileo... E4 / E6 / EZ: 1~ motor
DHS with horizontal outlet. DVS/DHS/DVSI sileo ...DV / DS: 3~ with Y/D-connection for 2-speeds
DVS with vertical outlet.
DVSI has a 50 mm mineral wool To protect the motors from overheating the sileo range motors are
insulation for lower noise levels. equipped with thermal contacts with external leads for connection to
a TK triggering device. REU p. 356
The casing is made from aluminum and the base frame from gal-
vanized steel. Suitable for coastal applications. The impellers of the
sileo types are manufactured from high-performance composite ma-
terial with highly efficient 3D fan blade profile technology.
REE p. 357

S2S 160
p. 381

S-DT2 SKT
p. 381

Technical data
DHS/DVS/DVSI sileo 190EZ 225EZ 311EV 400DS 400DV 400E4 400E6
Technical data is relating to DVS
Art. no. DHS 36290 36369 36064 36121 36122 36123 36124
Art. no. DVS 36289 36370 36068 36099 36109 36100 36101
Art. no. DVSI 36291 36371 36079 36110 36111 36112 36113
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~
Power W 52.4 110 132 123 491 466 152
Current A 0.231 0.466 0.574 0.255 1.21 2.32 0.654
Max. air flow m3/s 0.151 0.232 0.464 0.691 1.16 1.11 0.772
R.p.m. min-1 2337 2560 1342 779 1408 1344 896
Max. temp. of transported air °C 65 60 60 60 60 60 60
“ when speed controlled °C 65 60 60 60 60 60 60
Sound pressure level DVS** dB(A) 47/39 42/34 44/36 33/25 46/38 46/38 36/28
Weight kg 5.5/5/7 6.5/6/12 13/14/19 21/25/41 24/28/42 24/27/44 21/23.5/42
Insulation class, motor B F B F F F F
Enclosure class, motor 44 44 44 IP 54 IP 54 IP 54 IP 54
Capacitor µF 1.5 3 4 – – 9 5
Wiring diagram p. 442-461 20 20 20 18a 16 6b 6b

** at 4/10 m. DHS +2 dB, DVSI -9 dB


Roof Fans | 177

Dimensions Ventilation
DHS 190-500 DVS/DVSI DHS/DVS/DVSI accessories

øJ A F

B G M20x1,5

SSD p. 419
H

Roof fans
K
L

G
C
øD
øD øI(4x)
FDS p. 420
E øD
E
DHS 560-630
J

ASK p. 418
K
L

øD
E
VKS p. 427

DHS sileo £A £B C øD £E £F G H øI J K L
190, 225 - - - 213 335 245 105 6xM6 10 ø417 150 30
311 - - - 285 435 330 146 6xM6 10 ø540 250 30
400 - - - 438 595 450 200 6xM8 12 ø720 330 30 ASS p. 415
450-500 - - - 438 665 535 237 6xM8 12 ø830 490 30
560-630 - - - 605 939 750 293 8xM8 14 £1100 535 30

DVS sileo £A £B C øD £E £F G H øI J K L
190, 225 370 295 170 213 335 245 105 6xM6 10 - - - ASF p. 415
311 560 470 330 285 435 330 146 6xM6 10 - - -
400 720 618 390 438 595 450 200 6xM8 12 - - -
450-500 900 730 465 438 665 535 237 6xM8 12 - - -
560-630 1150 960 560 605 939 750 293 8xM8 14 - - -

DVSI sileo £A £B C øD £E £F G H øI J K L
190, 225 497 295 179 213 335 245 105 6xM6 10 - - -
311 690 470 369 285 435 330 146 6xM6 10 - - -
400 874 618 439 438 595 450 200 6xM8 12 - - -
450-500 968 748 479 438 665 535 237 6xM8 12 - - -
560-630 1315 960 600 605 939 750 293 8xM8 14 - - -

DHS/DVS/DVSI sileo 450DV 450E4 450E6 500DV


Technical data is relating to DVS
Art. no. DHS 36125 36126 36127 33356
Art. no. DVS 36102 36103 36104 33324
Art. no. DVSI 36114 36115 36116 33340
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 230 1~ 400 3~
Power W 683 659 280 1241
Current A 1.37 2.86 1.34 2.24
Max. air flow m3/s 1.51 1.46 1.04 2.08
R.p.m. min-1 1363 1305 939 1337
Max. temp. of transported air °C 60 60 60 60
“ when speed controlled °C 60 60 60 60
Sound pressure level DVS** dB(A) 49/41 49/41 40/32 53/45
Weight kg 29/38/53 32/40/56 28/38.5/53 30/48/62.5
Insulation class, motor F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54
Capacitor µF – 14 8 –
Wiring diagram p. 442-461 16 6b 6b 18a

**) at 4/10 m. DHS +2 dB, DVSI -9 dB


178 | Roof Fans

Quick selection
qv [m³/h] qv [m³/h]
0 500 1000 1500 2000 0 1000 2000 3000 4000 5000
500 700

Ps [Pa]
Ps [Pa]

9487, 9467, 9515, 9504, 9316, 9204, 9326


13077/13078/13217
1 DHS/DVS/DVSI sileo 400DS
1 DHS/DVS/DVSI sileo 190EZ 2 DHS/DVS/DVSI sileo 400DV, 450E4
600 3 DHS/DVS/DVS sileo 400E6
2 DHS/DVS/DVSI sileo 225EZ
400 4 DHS/DVS/DVS sileo 450DV
3 DHS/DVS/DVSI sileo 311EV 5 DHS/DVS/DVS sileo 450E4
500

300
Roof fans

400

300
200

200
5
100
100 1 3 2 4

1 2 3
0 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
qv [m³/s] qv [m³/s]

qv [m³/h] qv [m³/h]
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 0 4000 8000 12000 16000
800 1200
Ps [Pa]
Ps [Pa]

9538/9539/13058/13074/13224

10817/10993/13067/13069
1 DHS/DVS/DVSI sileo 450E6 1 DHS/DVS/DVSI sileo 560DV
2 DHS/DVS/DVSI sileo 500DV 2 DHS/DVS/DVSI sileo 560DS
3 DHS/DVS/DVSI sileo 500DS 1000 3 DHS/DVS/DVSI sileo 630DV
600
4 DHS/DVS/DVSI sileo 630DS
4 DHS/DVS/DVSI sileo 500E6
800

400 600

400
200

1 4 2 200
3
2 4 1 3
0 0
0 0.5 1 1.5 2 2.5
qv [m³/s] qv [m³/s]

DHS/DVS/DVSI sileo 500DS 500E6 560DV 560DS 630DV 630DS


Technical data is relating to DVS
Art. no. DHS 36128 36129 36131 36130 33361 33362
Art. no. DVS 36105 36106 36108 36107 33329 33330
Art. no. DVSI 36117 36118 36120 36119 33345 33346
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 446 504 2246 692 3991 1113
Current A 1.08 2.14 4.15 1.54 6.64 2.34
Max. air flow m3/s 1.4 1.52 3.13 2.1 4.45 2.75
R.p.m. min-1 918 889 1347 884 1355 854
Max. temp. of transported air °C 60 60 60 60 55 60
“ when speed controlled °C 60 60 60 60 55 60
Sound pressure level DVS** dB(A) 42/34 38/30 53/45 43/35 62/54 46/38
Weight kg 30/40/56.5 30/40/56.5 63/69/78 51/64/92 65/87.5/110 65/70/93
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF – 12 – – – –
Wiring diagram p. 442-461 18a 6b 18a 18a 18a 18a

** at 4/10 m. DHS +2 dB, DVSI -9 dB


Roof Fans | 179

Speed control

DHS/DVS/DVSI sileo Transformer Transformer Electronic Thyristor


Five step Five step high/low Two step Stepless
190EZ, 225EZ, 311EV - REU 1.5 - REE 1
450E6, 500E6 RTRE 3 REU 3 – REE 2
400E6 RTRE 1.5 REU 1.5 – REE 1

Roof fans
400E4, 450E4 RTRE 3 REU 3 – REE 4
400DV/DS, 500DS, 560DS RTRD 2 RTRDU 2 S-DT2SKT –
500DV, 560DV RTRD 4 RTRDU 4 S-DT2SKT –
630DV RTRD 14 – S-DT2SKT –
+ motor protection S-ET 10/STDT 16

Performance
Q [m³/h] Q [m³/h]
0 100 200 300 400 500 0 100 200 300 400 500 600 700 800
400 500

13077
13078

DHS/DVS/DVSI sileo 190 EZ DHS/DVS/DVSI sileo 225EZ


350
400
300

250 300
Ps [Pa]
Ps [Pa]

200

200
150

100
100

50

1 2 3 4 5
1 2 3 4 5 0
0
0 0.04 0.08 0.12 0.16
Q [m³/s]
Q [m³/s]
120
60
5 5
P [W]

40 80
P [W]

20 2 40 2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 39 57 61 63 62 59 54 47 LwA Inlet 68 39 57 61 63 62 59 54 47
LwA Surrounding 69 40 58 62 64 63 60 55 48 LwA Surrounding 69 40 58 62 64 63 60 55 48
DVSI DVSI
LwA Surrounding 64 51 53 57 59 58 55 50 43 LwA Surrounding 64 51 53 57 59 58 55 50 43
Measurement point: 0.09 m³/s @ 167 Pa Measurement point: 0.14 m³/s @ 245 Pa
180 | Roof Fans

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 0 400 800 1200 1600 2000 2400
300 200

13076
13219
DHS/DVS/DVSI sileo 311EV DHS/DVS/DVSI sileo 400DS
250
150

200
Ps [Pa]

Ps [Pa]
Roof fans

150 100

100
50

50

1 2 3 4 5 1 2 3 4 5
0 0
0 0.2 0.4 0.6
Q [m³/s]
180
160

P [W]
5
120 5 100
P [W]

80
2
40 1
0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 65 52 54 58 60 59 56 51 44 LwA Inlet 55 44 48 47 49 46 41 41 26
LwA Surrounding 67 54 56 60 62 61 58 53 46 LwA Surrounding 55 34 42 52 48 47 42 42 27
DVSI DVSI
LwA Surrounding 58 51 51 53 51 45 38 36 30 LwA Surrounding 46 25 33 43 39 38 33 33 18
Measurement point: 0.28 m³/s @ 167 Pa Measurement point: 0.38 m³/s @ 94 Pa

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 0 1000 2000 3000 4000
500 500
13050

13005
DHS/DVS/DVSI sileo 400DV DHS/DVS/DVSI sileo 400E4
400 400

300 300
Ps [Pa]

Ps [Pa]

200 200

100 100

1 2 3 4 5 1 2 3 4 5
0 0
0 0.2 0.4 0.6 0.8
Q [m³/s]

500 500
5 5
P [W]
P [W]

250 2 250
2

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 48 68 67 63 57 54 49 47 LwA Inlet 66 36 58 62 61 56 54 50 51
LwA Surrounding 72 49 70 64 64 62 57 51 49 LwA Surrounding 68 37 57 61 63 61 57 52 50
DVSI DVSI
LwA Surrounding 64 37 57 59 59 55 49 43 42 LwA Surrounding 64 38 57 60 59 55 47 43 43
Measurement point: 0.70 m³/s @ 320 Pa Measurement point: 0.61 m³/s @ 314 Pa
Roof Fans | 181

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 0 1000 2000 3000 4000 5000
250 600

13147

13008
DHS/DVS/DVSI sileo 400E6 DHS/DVS/DVSI sileo 450DV
500
200

400
150

Roof fans
Ps [Pa]

Ps [Pa]
300

100
200

50
100

0 1 2 3 4 5
0

200 800
5 5
P [W]

P [W]
100 400
2
2

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 56 36 50 50 52 45 41 39 28 LwA Inlet 66 40 57 60 61 57 55 52 52
LwA Surrounding 60 44 53 54 54 51 46 43 33 LwA Surrounding 70 40 55 62 66 64 59 54 51
DVSI DVSI
LwA Surrounding 56 35 50 50 53 43 38 42 25 LwA Surrounding 64 42 57 59 59 56 49 44 44
Measurement point: 0.42 m³/s @ 141 Pa Measurement point: 0.91 m³/s @ 372 Pa

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000
600 300
13057

13058
DHS/DVS/DVSI sileo 450E4 DHS/DVS/DVSI sileo 450E6
500 250

400 200
Ps [Pa]
Ps [Pa]

300 150

200 100

100 50

1 2 3 4 5 1 2 3 4 5
0 0

800 400
P [W]

5
P [W]

5
400 200
2 2

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 42 56 64 63 60 58 56 53 LwA Inlet 57 37 45 53 53 48 46 44 35
LwA Surrounding 72 47 58 67 67 66 61 55 50 LwA Surrounding 62 38 49 58 59 54 49 44 33
DVSI DVSI
LwA Surrounding 66 46 58 61 60 58 50 45 40 LwA Surrounding 58 31 46 53 52 45 38 38 26
Measurement point: 0.81 m³/s @ 361 Pa Measurement point: 0.63 m³/s @ 177 Pa
182 | Roof Fans

Q [m³/h]
0 1000 2000 3000 4000 5000
400

13074
DHS/DVS/DVSI sileo 500DS
DHS/DVS/DVSI sileo 500DV 350

300

250

Ps [Pa]
Roof fans

200

150

100

50

1 2 3 4 5
0

500
5

P [W]
250
2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 76 47 62 73 69 66 62 59 57 LwA Inlet 62 46 55 57 56 51 49 46 38
LwA Surrounding 77 47 65 68 73 71 67 62 57 LwA Surrounding 64 41 50 60 59 56 52 48 40
DVSI DVSI
LwA Surrounding 73 52 64 67 67 65 61 58 57 LwA Surrounding 61 44 51 58 54 52 43 38 34
Measurement point: 1.25 m³/s @ 449 Pa Measurement point: 0.84 m³/s @ 207 Pa

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 5000 0 2500 5000 7500 10000 12500
400 1000
13224

13069
DHS/DVS/DVSI sileo 500E6 DHS/DVS/DVSI sileo 560DV
350
800
300

250
Ps [Pa]

600
Ps [Pa]

200

400
150

100
200
50

1 2 3 4 5 1 2 3 4 5
0 0

400
2000
P [W]

5
P [W]

200
1000 2

2 5
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 42 55 58 58 51 49 45 38 LwA Inlet 73 44 62 66 68 67 64 59 52
LwA Surrounding 62 41 48 57 58 55 50 44 37 LwA Surrounding 75 46 64 68 70 69 66 61 54
DVSI DVSI
LwA Surrounding 58 42 50 54 52 48 41 36 30 LwA Surrounding 66 59 59 61 59 53 46 44 38
Measurement point: 0.84 m³/s @ 236 Pa Measurement point: 1.89 m³/s @ 570 Pa
Roof Fans | 183

Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 0 2500 5000 7500 10000 12500 15000 17500
450 1200

10817
13067
DHS/DVS/DVSI sileo 560DS DHS/DVS/DVSI sileo 630DV
400
1000
350

300 800

Roof fans
Ps [Pa]

Ps [Pa]
250
600
200

150 400

100
200
50

1 2 3 4 5 1 2 3 4 5
0 0

800 1500
P [W]

600 5

P [W]
1000
400
2 500
200
2 5
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 34 52 56 58 57 54 49 42 LwA Inlet 83 54 72 76 78 77 74 69 62
LwA Surrounding 65 36 54 58 60 59 56 51 44 LwA Surrounding 85 56 74 78 80 79 76 71 64
DVSI DVSI
LwA Surrounding 56 49 49 52 49 44 36 34 27 LwA Surrounding 76 69 69 71 69 63 56 54 48
Measurement point: 1.27 m³/s @ 243 Pa Measurement point: 2.2 m³/s @ 788 Pa

DVS sileo 630DS

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 38 56 60 62 61 58 53 46
LwA Surrounding 69 40 58 62 64 63 60 55 48
DVSI
LwA Surrounding 60 31 49 53 55 54 51 46 39
Measurement point: 1.74 m³/s @ 268 Pa
184 | Roof Fans

DHS / DVS / DVSI ElectrIcal


accessories
• Speed controllable
• Integral thermal contacts
• Low sound level
DHS • Maintenance-free and reliable
S-ET/STDT
p. 373
DHS 710 The DVS/DHS/DVSI models have impellers with backward curved
Roof fans

blades and external rotor motors. All motors are speed controllable
by voltage. Frequency inverters must have an allpole sine filter. The
motors are suspended on effective vibration dampers.

DVS DVS/DHS/DVSI...EZ/EV/ES: 1~ motor with connection for 2-speeds RTRE p. 356


DVS/DHS/DVSI...E4:1-speed motor
DVS/DHS/DVSI...DV/DS:3~ with Y/D-connection for 2-speeds

DVSI To protect the motors from overheating the DVS/DHS/DVSI up to


size 311 have integral thermal contacts, from size 355 with exter- RTRD/RTRDU
nal leads for connection to a TK triggering device. The casing is made p. 357
from aluminum and the base from galvanized steel. Suitable for
coastal applications. The impellers up to size 355 are manufactured
from polyamide PA6 25GV, from size 400 in aluminium.
DVS with outlet vertical DHS with outlet horizontal DVSI with 50 mm
mineral wool insulation for low noise level.
REU p. 356
Quick selection
qv [m³/h] qv [m³/h]
0 200 400 600 800 1000 1200 1400 1600 0 2000 4000 6000 8000 10000 12000 14000 16000
300 1000
Ps [Pa]

5240/5242/13082/13531/13532
Ps [Pa]
5218/5220/5229

1 DHS/DVS/DVSI 225EV 1 DHS/DVS/DVSI 311ES


900
2 DHS/DVS/DVSI 355E4
250 2 DHS/DVS/DVSI 310EV REE p. 357
800 3 DHS/DVS/DVSI 355DV
3 DHS/DVS/DVSI 310ES 4 DHS/DVS/DVSI 710DS
700 5 DHS/DVS/DVSI 710DS-L
200
600

150 500
S2S 160
400
p. 381
100 300 2
3
200
50
1 2
3 100 4 5
1

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 S-DT2 SKT
qv [m³/s] p. 381
qv [m³/s]

Technical data
DHS/DVS/DVSI 225EV 310EV 310ES 311ES 355E4 355DV 710DS 710DS-L
Technical data is relating to DVS
Art. no. DHS 5714 5703 5704 5715 5706 5707 36204 36207
Art. no. DVS 5732 5733 5734 5736 5737 5710 36202 36205
Art. no. DVSI 30274 2347 2350 2381 2356 2354 36203 36206
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 400 3~ 400 3~
Power W 48 114 70 86.5 260 249 2040 2482
Current A 0.227 0.53 0.37 0.37 1.2 0.58 4.04 5.34
Max. air flow m3/s 0.142 0.406 0.369 0.447 0.774 0.779 4.04 4.4
R.p.m. min-1 1422 1375 1000 974 1397 1350 909 914
Max. temp. of transp. air °C 40 40 40 40 40 40 40 40
“ when speed controlled °C 40 40 40 40 40 40 40 40
Sound pressure level DVS** dB(A) 41/33 44/36 37/29 38/30 47/39 47/39 58/50 65/57
Weight kg 6.5/5.5/8 12/13.5/19 11.5/13/18.5 12/13/18.5 22.5/19.5/26 21.5/19/28 95/88/152 56/88/104
Insulation class, motor B B B B B B F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 54 IP 54
Capacitor µF 2 4 1.5 2 8 – - -
Wiring diagram p. 442-461 20 20 20 20 5 16 16a 16a

**) at 4/10 m. DHS +2 dB, DVSI -9 dB


Roof Fans | 185

Dimensions Ventilation
accessories
DHS 190-355 DVS/DVSI DHS/DVS/DVSI
øJ A F

B G M20x1,5
SSD p. 419
H

Roof fans
K
L

G
C
øD
øD øI(4x) FDS p. 420

E øD
E
DHS 710
J ASK p. 418
K
L

øD VKS p. 427
E

DHS £A £B C øD £E £F G H øI J K L
225 – – – 213 335 245 105 6xM6 10 ø417 150 30
310, 311 – – – 285 435 330 146 6xM6 10 ø540 250 30 ASS p. 415
355 – – – 438 595 450 200 6xM8 12 ø720 330 30
710 – – – 674 1035 840 320 8xM8 14 £1282 580 40

DVS £A £B C øD £E £F G H øI J K L
225 370 295 170 213 335 245 105 6xM6 10 – – – ASF p. 415
310, 311 560 470 330 285 435 330 146 6xM6 10 – – –
355 720 618 390 438 595 450 200 6xM8 12 – – –
710 1350 1185 660 674 1035 840 320 8xM8 14 – – –

DVSI £A £B C øD £E £F G H øI J K L
225 497 295 179 213 335 245 105 6xM6 10 _ – –
310, 311 690 470 369 285 435 330 146 6xM6 10 – – –
355 874 618 439 438 595 450 200 6xM8 12 – – –
710 1483 1185 729 674 1035 840 320 8xM8 14 – – –

Speed control

DHS/DVS/DVSI Transformer Transformer Electronic Thyristor


Five step Five step high/low Two step Stepless
225EV-311ES RE 1.5 REU 1.5 S2S 160 REE 1
355E4 RTRE 1.5 REU 1.5 – REE 2
355DV RTRD 2 RTRDU 2 S-DT2SKT –
710DS RTRD 4 RTRDU 4 S-DT2SKT -
710DS-L FRQ5S FRQ5S – –
+ motor protection S-ET 10/STDT 16
186 | Roof Fans

Performance
Roof fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 34 52 56 58 57 54 49 42 LwA Inlet 65 52 54 58 60 59 56 51 44
LwA Surrounding 64 35 53 57 59 58 55 50 43 LwA Surrounding 67 54 56 60 62 61 58 53 46
DVSI DVSI
LwA Surrounding 58 51 51 53 51 45 38 36 30 LwA Surrounding 58 51 51 53 51 45 38 36 30
Measurement point: 0.07 m³/s @ 87 Pa Measurement point: 0.223 m³/s @ 172 Pa

Q [m³/h] Q [m³/h]
0 200 400 600 800 1000 1200 1400 0 200 400 600 800 1000 1200 1400 1600
200 250

13082
5229

DHS/DVS/DVSI 310ES DHS/DVS/DVSI 311ES


200
150

150
Ps [Pa]

Ps [Pa]

100

100

50
50

2 3 4 5
1 1 2 3 4 5
0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45

80 100
5 5
60
P [W]

P [W]

40 50
3
20 3
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 58 45 47 53 53 53 49 44 36 LwA Inlet 59 46 48 53 54 54 50 45 37
LwA Surrounding 60 47 49 54 55 55 51 46 38 LwA Surrounding 61 48 50 55 56 56 52 47 39
DVSI DVSI
LwA Surrounding 51 44 44 47 44 39 31 29 22 LwA Surrounding 52 45 45 48 45 40 32 30 23
Measurement point: 0.15 m³/s @ 98 Pa Measurement point: 0.246 m³/s @ 79 Pa
Roof Fans | 187

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500
350 350

5240

5242
DHS/DVS/DVSI 355E4 DHS/DVS/DVSI 355DV
300 300

250 250

Roof fans
Ps [Pa]
200 200
Ps [Pa]

150 150

100 100

50 50

2 3 4 5 2 3 4 5
0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Q [m³/s]

300 300

P [W]
5 5
200 200
P [W]

3
100 100 3

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 55 57 61 63 62 59 54 47 LwA Inlet 68 55 57 61 63 62 59 54 47
LwA Surrounding 70 57 59 63 65 64 61 56 49 LwA Surrounding 70 57 59 63 65 64 61 56 49
DVSI DVSI
LwA Surrounding 61 54 54 56 54 48 41 39 33 LwA Surrounding 61 54 54 56 54 48 41 39 33
Measurement point: 0.45 m³/s @ 240 Pa Measurement point: 0.45 m³/s @ 240 Pa

Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 10000 12000 14000 0 4000 8000 12000 16000
700 800

13531
13532

DHS/DVS/DVSI 710DS DHS/DVS/DVSI 710DS-L


600

600
500
Ps [Pa]

400
Ps [Pa]

400
300

200
200

100

1 2 3 4 5 1 2 3 4 5
0 0

Q [m³/s] Q [m³/s]

2500 800
2000 600
P [W]
P [W]

1500
3 5 400
1000
500 200
3 5
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 66 68 73 74 74 70 65 57 LwA Inlet 82 56 67 73 74 76 77 74 63
LwA Surrounding 81 68 70 75 76 76 72 67 59 LwA Surrounding 88 63 72 81 82 83 79 77 67
DVSI DVSI
LwA Surrounding 72 65 65 68 65 60 52 50 43 LwA Surrounding 79 59 70 71 73 71 69 68 61
Measurement point: 2.42 m³/s @ 437 Pa Measurement point: 2.42 m³/s @ 484 Pa
188 | Roof Fans

DVN / DVNI Electrical


accessories
• Integral cold conductor (PTC) or thermal contacts (TK)
• Speed-controllable via frequency converter (IE2-Versions)
• Standard motor outside the air stream
• Max. temperature of transported air 120°C
• Suitable for coastal applications SET/STDT
• p. 373
Roof fans

Vertical exhaust
• Low sound level
• Easy to maintain and reliable

IE2
2009/640/EG
The casing and impeller with backward curved blades is manufactured
from seawater resistant aluminum. The base frame is manufactured REU p. 356
120°C from galvanized steel and the integrated protection guard consist of
powder-coated galvanized steel.
The motor is suspended on effective vibration dampers. The single-
phase motor is speed-controllable via transformer and the three-phase
motor additionally via D/Y connection. IE2 motors can only be speed RTRE p. 356
controlled by frequency. To protect the motor from overheating the fan
has integral thermal contact (TK) or cold conductors (PTC) with external
leads for connection to a triggering device.
The DVNI version has a 50 mm mineral wool insulation for lower
sound level.
RTRD/RTRDU
Quick selections p. 357
qv [m³/h] qv [m³/h]
0 2000 4000 6000 8000 0 4000 8000 12000 16000
800 1200
Ps [Pa]

Ps [Pa]

9777/9778/9779/9780/9860
5222/5226/5307/6803/6804/9775/9776

1 DVN/DVNI 355E4 1 DVN/DVNI 560D4 IE2


700 2 DVN/DVNI 355DV 2 DVN/DVNI 560D6 IE2
3 DVN/DVNI 400E4 1000 3 DVN/DVNI 630D4 IE2
4 DVN/DVNI 400DV DVN/DVNI 630D6 IE2 FXDM p. 371
600 4
5 DVN/DVNI 450D4 IE2 5 DVN/DVNI 710D6 IE2
6 DVN/DVNI 500D4 IE2 800
500
7 DVN/DVNI 500DS

400 600

300
400
FRQ p. 361
200
1 4
200
100
3
2 3 7 5 6 2 4 1 5
0 0
REV p. 380
qv [m³/s] qv [m³/s]
Technical data
DVN/DVNI 355E4 355DV 400E4 400DV 450D4 IE2 500D4 IE2 500DS
Art. no. DVN, Technical data is relating to DVN 30301 30278 2630 2631 32184 32185 9852
Art. no. DVNI 30446 30313 3909 3396 33462 33463 9857
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 230 1~ 400 3~ 400 Y 3~ 400 Y 3~ 400 3~
Power at shaft (P1) W 338 327 440 526 864 1361 422
Current A 1.49 1.20 2.00 1.37/1.4 1.78 3.39 1.86
Max. air flow m3/s 0.846 0.839 1.00 1.1 1.64 2.18 1.41
R.p.m. min-1 1408 1420 1420 1442 1390 1400 936
Max. temp. of transported air °C 120 120 120 120 120 120 120
Sound pressure level at 4 m/10 m* dB(A) 49/41 50/42 52/44 52/44 53/45 56/48 47/39
Weight kg 26/37 26/36 31/41 31/41 51/59 57/66 49/57
Insulation class, motor F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 55 IP 55 IP 54
Capacitor µF 12 – 12 – – – –
Motor protection S-ET 10 STDT 16 S-ET 10 STDT 16 U-EK230E U-EK230E STDT 16
Speed control, five-step RTRE 3 RTRD 2 RTRE 3 RTRD 2 FRQ5(S)-4A FRQ5(S)-4A RTRD 2
Speed control, five step high/low Transformer REU 3** RTRDU 2 REU 3** RTRDU 2 – – RTRDU 2
Speed control, two step – S-DT2SKT – S-DT2SKT – – S-DT2SKT
Speed control, stepless – FRQ(S)-4A – FRQ(S)-4A FRQ(S)-4A FRQ(S)-4A FRQ(S)-4A
Wiring diagram p. 442-461 21 17c 21 17c 17a 17a 17c
* DVNI -9 dB, ** + S-ET 10
Roof Fans | 189

Dimensions Ventilation
A accessories

B

DVN £A £B C D øE £F £G H øI J
355-400 720 618 600 390 438 595 450 200 12(4x) 6xM8
SSD p. 419
450-500 900 730 675 465 438 665 535 237 12(4x) 6xM8

Roof fans
560-630 1150 955 900 560 605 939 750 293 14(4x) 8xM8
D
C

710 1350 1178 936 660 674 1035 840 320 14(4x) 8xM8

FDS p. 420
øE
F
DVNI £A £B C D øE £F £G H øI J
G 355-400 874 648 600 439 438 595 450 200 12(4x) 6xM8
450-500 970 730 675 479 438 665 535 237 12(4x) 6xM8
ASK p. 418
H
M20x1,5 560-630 1315 1035 900 600 605 939 750 293 14(4x) 8xM8
J 710 1483 1165 936 729 674 1035 840 320 14(4x) 8xM8
H

øE VKS p. 427
øI

VKM p. 427

ASS p. 415

ASF p. 415

DVN/DVNI 560D4 IE2 560D6 IE2 630D4 IE2 630D6 IE2 710D6 IE2 710D6-L IE2
Art. no. DVN, Techn. data is relating to DVN 32187 32188 33554 32189 33555 33669
Art. no. DVNI 33465 33466 33468 33467 33469 33670
Voltage/Frequency V/50 Hz 400 Y 3~ 400 Y 3~ 400 D 3~ 400 Y 3~ 400 Y 3~ 400 Y 3~
Power at shaft (P1) W 2216 766 4535 1337 2386 3063
Current A 5.2 1.81 8.12 2.96 5.1 5.1
Max. air flow m3/s 3.0 2.0 4.1 2.7 4.0 5.0
R.p.m. min-1 1374 962 1450 975 945 945
Max. temp. of transported air °C 120 120 120 120 120 120
Sound pressure level at 4/10 m dB(A) 64/56 49/41 66/58 53/45 58/50 62/54
Weight kg 86/103 73/91 105/122 91/108 110/132 110/132
Insulation class, motor F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Motor protection U-EK230E U-EK230E U-EK230E U-EK230E U-EK230E U-EK230E
Speed control, five-step FRQ5(S)-10A FRQ5(S)-4A FRQ5(S)-10A FRQ5(S)-4A FRQ5(S)-10A FRQ5(S)-10A
Speed control, stepless FRQ(S)-10A FRQ(S)-4A FRQ(S)-10A FRQ(S)-4A FRQ(S)-10A FRQ(S)-10A
Wiring diagram p. 442-461 17a 17a 17b 17a 17a 17a
190 | Roof Fans

Performance
Roof fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 41 59 63 65 64 61 56 49 LwA Inlet 70 41 59 63 65 64 61 56 49
LwA Surrounding 72 43 61 65 67 66 63 58 51 LwA Surrounding 72 43 61 65 67 66 63 58 51
DVNI DVNI
LwA Surrounding 63 34 52 56 58 57 54 49 42 LwA Surrounding 63 34 52 56 58 57 54 49 42
Measurement point: 0.51 m³/s @ 290 Pa Measurement point: 0.443 m³/s @ 299 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 60 62 66 68 67 64 59 52 LwA Inlet 73 60 62 66 68 67 64 59 52
LwA Surrounding 75 62 64 68 70 69 66 61 54 LwA Surrounding 75 62 64 68 70 69 66 61 54
DVNI DVNI
LwA Surrounding 66 59 59 61 60 56 47 45 39 LwA Surrounding 66 59 59 61 60 56 47 45 39
Measurement point: 0.57 m³/s @ 327 Pa Measurement point: 0.66 m³/s @ 327 Pa
Roof Fans | 191

Q [m³/h]
0 2000 4000 6000
600

9775
DVN/DVNI 450D4 IE2
500 DVN/DVNI 500D4 IE2

400

Roof fans
Ps [Pa]

300

200

100

1
0

Q [m³/s]

1000
P [W]

500

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 61 63 67 69 68 65 60 53 LwA Inlet 77 64 66 70 72 71 68 63 56
LwA Surrounding 76 63 65 69 71 70 67 62 55 LwA Surrounding 79 66 68 72 74 73 70 65 58
DVNI DVNI
LwA Surrounding 67 60 60 62 60 54 47 45 39 LwA Surrounding 70 63 63 65 63 57 50 48 42
Measurement point: 1.11 m³/s @ 489 Pa Measurement point: 1.31 m³/s @ 535 Pa

DVN/DVNI 560D4 IE2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 55 57 62 63 63 59 54 46 LwA Inlet 79 66 68 72 74 73 70 65 58
LwA Surrounding 70 57 59 64 65 65 61 56 48 LwA Surrounding 86 73 75 79 81 80 77 72 65
DVNI DVNI
LwA Surrounding 61 54 54 57 54 49 41 39 32 LwA Surrounding 77 70 70 72 70 64 57 55 49
Measurement point: 0.847 m³/s @ 216 Pa Measurement point: 1.8 m³/s @ 606 Pa
192 | Roof Fans

DVN/DVNI 560D6 IE2 DVN/DVNI 630D4 IE2


Roof fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 57 59 64 65 65 61 56 48 LwA Inlet 87 74 76 80 82 81 78 73 66
LwA Surrounding 72 59 61 66 67 67 63 58 50 LwA Surrounding 89 76 78 82 84 83 80 75 68
DVNI DVNI
LwA Surrounding 63 56 56 59 56 53 44 42 34 LwA Surrounding 80 73 73 75 73 69 61 59 52
Measurement point: 1.22 m³/s @ 305 Pa Measurement point: 2.44 m³/s @ 958 Pa

Q [m³/h]
0 2500 5000 7500 10000
500
9779

DVN/DVNI 630D6 IE2


DVN/DVNI 710D6 IE2
400
Ps [Pa]

300

200

100

Q [m³/s]

1600

1200
P [W]

800

400

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 61 63 68 69 69 65 60 52 LwA Inlet 79 66 68 73 74 74 70 65 57
LwA Surrounding 76 63 65 70 71 71 67 62 54 LwA Surrounding 81 68 70 75 76 76 72 67 59
DVNI DVNI
LwA Surrounding 67 60 60 63 60 57 48 46 38 LwA Surrounding 72 65 65 67 65 62 53 51 44
Measurement point: 1.6 m³/s @ 414 Pa Measurement point: 2.41 m³/s @ 488 Pa
Roof Fans | 193

DVN/DVNI 710D6-L IE2

Roof fans
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 83 51 68 73 74 78 77 75 67
LwA Surrounding 87 52 69 77 83 81 79 77 69
DVNI
LwA Surrounding 81 60 70 74 76 75 72 69 63
Measurement point: 3.0 m³/s @ 488 Pa
194 | Roof Fans

DVV Electrical
accessories
• Motor outside of the air stream
• Max. temperature of transported air 120°C
• Vertical exhaust
• Suitable for coastal applications
FRQ p. 361
• Wide range of accessories
Roof fans

The octagonal casing is manufactured from seawater resistant


aluminium. The base frame is manufactured from galvanized steel.
The impeller with backward curved blades is also manufactured FXDM p. 371
from galvanized steel.
The fan is equipped with IEC standard motors, according to
IE2
2009/640/EG
2009/640/EC guideline and IEC 60034-30. Single speed or two
speed Dahlander connected (4-8,6-12 pole) or with separate
120°C
windings (6-8, 4-6, 8-12 pole).
Motor cooling with fresh air via air duct. Thermal motor protec-
Note: Data related to motor and weight tion PTC in single speed motors serial, in two speed motors up to
of delivered items can slightly vary from table respectively on request. For speed control use frequency
catalogue data due to different motor inverters only with appropriate filter to motor side. At frequency
suppliers. controlled units additional EMC protection may be needed (on re-
quest).
The DVV fans can be factory fitted with sound attenuators at the
outlet (DVVI). Sound attenuators are also available as HSDV acces-
sories.

The new range of DVV-XS, XL on the new base frames with


Eurovent connection is also available as DVV/120 - please see
page 278.

Technical data
DVV 120°C 630 D4 IE2 630D4-6 630D6 IE2 800D4-K IE2 800D4-M IE2 800D4-P IE2 800D4-6-P
Art. no. 95142 3586 95143 95144 95148 95149 30052
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power (P1) kW 6.7 6.7/2.57 2.57 11.02 17.61 20.0 20/7.7
Current A 11.6 12/4.5 5.5 18 29.8 35 36/19
Starting current A 95 81.6/20.3 25.3 121 265 280 244/110
Max. air flow m3/s 5.36 5.36/3.36 3.36 7.08 9.58 10.8 10.8/7.25
R.p.m. min-1 1455 1460/970 935 1445 1470 1465 1460/985
Max. temp. of transported air °C 120 120 120 120 120 120 120
Sound pressure level at 4 m dB(A) 75 75/64 64 76 80 83 83/71
Sound pressure level at 10 m dB(A) 69 69/58 58 70 72 75 75/64
Weight kg 124 134 114 224 265 353 369
Insulation class, motor F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
PTC serial built-in yes - yes yes yes yes yes
Service switch serial yes yes yes yes yes yes yes
Wiring diagram p. 442-461 13c 15a 15c 13c 13c 13c 13d
Roof Fans | 195

Dimensions Ventilation
accessories

ød1 nxM
ASFV p. 429

Roof fans
G

C
B

A
ASK/F p. 418

F
ød2

ASSV p. 428
øds
H

ød

SSV p. 425
DVV £A £B £C ød ød1 ød2 øds F G H nxM
630 995 880 990 500 541 18 452 1100 958 40 12xM8
800 995 880 990 630 674 18 566 1272 1165 40 16xM10
800-M, P 995 880 990 630 674 18 566 1350 1280 40 16xM10
1000 1160 1040 1154 710 751 18 710 1500 1350 70 16xM10 SSVE p. 422
1000D4, M, P 1160 1040 1154 710 751 18 710 1500 1479 70 16xM10

FDV p. 420

FDVE p. 420

VKV/F p. 428

VKVM
p. 429

DVV 120°C 800D6 IE2 800D8 1000D6 IE2 1000D6-8 1000D4-M IE2 1000D4-P IE2 1000D4-6-P 1000D4-8-P
Art. no. 95146 3657 95147 3663 95151 95150 31265 31269
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Input power kW 6,39 3,52 12.05 12.05/6.5 26.099 29.072 29.072/9.04 29.072/5.13
Current A 12.6 5.5 22 22/15 42 56 53.5/18 51/20
Starting current A 76 25.2 156 154/82.5 340 420 360/120 400/80
Max. air flow m3/s 7.08 5.28 12.4 12.4/9.44 14.2 15.2 15.2/10.1 15.2/7.56
R.p.m. min-1 960 690 955 970/730 1470 1470 1470/980 1470/730
Max. temp. of transported air °C 120 120 120 120 120 120 120 120
Sound pressure level at 4 m dB(A) 72 66 74 74/66 89 90 90/78 90/71
Sound pressure level at 10 m dB(A) 64 57 66 66/58 79 79 79/67 79/60
Weight kg 179 165 353 400 469 495 520 520
Insulation class, motor F F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
PTC serial built-in yes yes yes yes yes yes yes yes
Service switch serial yes yes yes yes yes yes yes yes
Wiring diagram p. 442-461 13 c 13c 13c 13d 13c 13c 13d 14c
196 | Roof Fans

Performance
Roof fans

98

97

87

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 97 68 79 91 90 92 87 81 72 LwA Inlet 98 71 83 91 92 91 89 86 78
LwA Surrounding 98 68 87 88 91 91 91 89 79 LwA Surrounding 99 72 84 92 93 92 90 87 79
Measurement point: 4.58 m³/s @ 370 Pa Measurement point: 5.6 m³/s @ 740 Pa
6-pole
LwA Inlet 87 64 73 79 83 78 76 74 62
LwA Surrounding 88 65 74 80 84 79 77 75 63
Measurement point: 2.3 m³/s @ 290 Pa

6-pole

8-pole
101

93

82

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
6-pole 4-pole
LwA Inlet 93 70 79 85 89 84 82 80 68 LwA Inlet 101 74 86 94 95 94 92 89 81
LwA Surrounding 95 72 81 87 91 86 84 82 70 LwA Surrounding 103 76 88 96 97 96 94 91 83
Measurement point: 6.1 m³/s @ 250 Pa Measurement point: 8.1 m³/s @ 740 Pa
8-pole
LwA Inlet 82 64 70 73 77 74 74 69 58
LwA Surrounding 84 66 72 75 79 76 76 71 60
Measurement point: 4.3 m³/s @ 200 Pa
Roof Fans | 197

92

Roof fans
104

84

91

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 6-pole
LwA Inlet 104 77 89 97 98 97 95 92 84 LwA Inlet 92 69 78 84 88 83 81 79 67
LwA Surrounding 106 79 91 99 100 99 97 94 86 LwA Surrounding 94 71 80 86 90 85 83 81 69
Measurement point: 8.6 m³/s @ 740 Pa Measurement point: 6.94 m³/s @ 650 Pa
6-pole 8-pole
LwA Inlet 91 67 78 80 87 82 81 77 64 LwA Inlet 84 66 72 75 79 76 76 71 60
LwA Surrounding 93 69 80 82 89 84 83 79 66 LwA Surrounding 86 68 74 77 81 78 78 73 62
Measurement point: 5.6 m³/s @ 330 Pa Measurement point: 6.11 m³/s @ 310 Pa

104
105

93

84

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 104 82 91 97 100 96 94 92 80 LwA Inlet 105 82 91 97 101 96 94 92 80
LwA Surrounding 109 87 96 102 105 101 99 97 85 LwA Surrounding 110 87 96 102 106 101 99 97 85
Measurement point: 7.3 m³/s @ 1600 Pa Measurement point: 9.2 m³/s @ 1580 Pa
6-pole
LwA Inlet 93 75 81 84 88 85 85 80 69
LwA Surrounding 98 80 86 89 93 90 90 85 74
Measurement point: 7.1 m³/s @ 560 Pa
8-pole
LwA Inlet 84 66 72 75 79 76 76 71 60
LwA Surrounding 91 73 79 82 86 83 83 78 67
Measurement point: 6.1 m³/s @ 220 Pa
198 | Roof Fans

ZRS Electrical
accessories
• Cast aluminium casing
• For 200°C permanent operation
• With armoured cable
• Supplied with insulation material and fixing rods
REU p. 356
Fans are supplied with 1 m armoured cable and a junction box. Steel
Roof fans

cables are provided to give extra support for the fan during chimney
sweeping and similar operations.
The flue-gas fans have a casing of cast aluminium alloy. The ZRS
170 impeller is made of silumin alloy, while the ZRS 180 impeller is REE p. 357
200°C made of stainless steel.
The ZRS 170 is suitable for smaller fireplaces with an aperture of
less than 0.35 m2, and the ZRS 180 is intended for fireplaces with an
aperture between 0.35 and 0.80 m2.
Systemair flue-gas fans counteract drafts caused by stoves, ovens
and open fireplaces. Flue-gas fans are positioned on the top of the RE p. 356
chimney and fixed with four adjustable locating rods which are in-
serted down the chimney. This means that no fixing into the chimney
itself is required. The fan is a discreet and compact unit with a low
profile.

Dimensions

300
180

Insulation
material

ø132
Fixing rods

Technical data
ZRS 170 180
Art. no. 1665 1667
Voltage/Frequency V/50 Hz 230 1~ 230 1~
Power W 42.9 55.5
Current A 0.19 0.26
Max. air flow m3/s 0.0861 0.144
R.p.m. min-1 2566 2746
Max. temp. of transported air °C 200 200
“ when speed controlled °C 200 200
Sound pressure level at 10 m dB(A) 37 41
Weight kg 7.3 8.2
Insulation class, motor F F
Enclosure class, motor IP 44 IP 44
Capacitor µF 1.5 2
Speed control, five step Transformer RE 1.5 RE 1.5
Speed control, stepless Thyristor REE 1 REE 1
Wiring diagram p. 442-461 2 2
Roof Fans | 199

Performance

Roof fans
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 54 62 64 65 60 59 48 37 LwA Inlet 67 33 48 60 62 60 58 50 48
LwA Surrounding 68 38 59 58 59 63 61 53 40 LwA Surrounding 74 33 51 68 66 68 66 60 55
Measurement point: 0.0387 m³/s @ 128 Pa Measurement point: 0.0718 m³/s @ 205 Pa
200 | Axial Fans

Axial Fans
IE2
Axial fans

2009/640/EG
200°C

14

7 15
6

12
1 13
2
3
4
5

9
10

11

General Motors
Systemair axial fans have been devel- Especially for industrial buildings the AXC The Systemair AR/AW range is equipped
oped for the installation in effective sup- range offers a wide area of applications. with external rotor motors, speed con-
ply and exhaust air systems. AXC is equipped with profiled aluminium trollable by voltage. All external rotor
Ranges AR sileo and AW sileo are de- blades with casing either hot dip galva- motors have thermal contacts embed-
signed for the use in low pressure sys- nized or in our economy version AXC-E, ded in the motor windings. The TK-leads
tems. The impellers are available either pre-galvanized. A comprehensive range have to be connected to an external TK
in die cast aluminium or in high tech of accessories is available. triggering device. Axial fans of the range
composite material, depending on the AW sileo EC are driven by high efficient,
sizes. The AW-EC range impellers are Systemair range energy saving EC-external rotor motors.
manufactured from fiber-reinforced plas- The power electronics is integrated in the
The Systemair AR axial fan casings are
tic (PP) with metal core. The long casings motor casing/terminal box. Systemair
designed for duct mounting, the AW fan
for ducted installation as well as the wall also offers a range of explosion proof
casings for direct wall mounting. From
plates for wall mounting are manufac- ATEX axial fans, (see chapter EX-fans).
sizes 200 up to 1000 mm.
tured from galvanized, powder coated AXC is equipped with IEC standard
Due to adjustable fan blades and dif-
steel. motors, in IE2 according to the latest EN-
ferent motor options the Systemair AXC
The AXC range is designed for the use standards with PTC thermistors for ther-
axial fans can be selected to match the
in medium/high pressure systems. mal motor protection. PTC thermistors
exact duty points required for a project.
have to be connected to an external PTC
Available from sizes 315 to 2000 mm.
triggering device.
Axial Fans | 201

Axial fans
1 SG Protection guard 11 ZSD Spring mounts for
16
ESD-F Inlet cone tensile load
17 2
18
12 LRK Air operated damper
3 RSA Silencer
19
13 GFL Counterflange
4 EV-AXC Flexible connection
14 REV On/Off switch
5 MPR Mounting ring
AXC Axial fan 15 REV(F) On/Off switch (smoke
6
extract)
7 MP Mounting brackets
16 VK Louvre shutter
8 MFA Mounting feet
17 SG-AW-D Protection guard
9 SD Rubber mounts
16 18 AW Axial fan
1 10 FSD Spring mounts
20
19 SG-AW Protection guard
4
13 20 AR Axial fan

8 9

AW sileo EC NEW!
202 AR sileo NEW!
210 AXCBF IE2
226
2009/640/EG
200°C

Axial wall fan with EC motor, Axial duct fan, Thermo axial fan, up to
low noise level low noise level 200°C transported air

AW sileo NEW!
208 AXC IE2
220
2009/640/EG

Axial wall fan, Axial fan


low noise level
202 | Axial Fans

AW sileo EC NEW! Electrical


accessories
• 100% speed controllable
• Electric connection via terminal box mounted on the motor
• Inlet protection guard
• Integrated motor protection
EC-Vent
• Safe and maintenance free operation p. 365
• Installation in any mounting position

Axial fans of the range AW sileo EC are driven by high efficient,


energy saving EC-external rotor motors. The power electronics is
integrated in the motor casing/terminal box. All motors are suit- MTP 10
able to be used for 50/60Hz. The input voltage for single phase p. 359
Axial fans

units can vary between 200 and 240V. Speed control by a 0-10V
signal.
The AW sileo EC range is equipped with a square wall plate
made from galvanized steel and is completely powder coated in
black (RAL9005). The protection guard at the inlet side is powder MTP 20
p. 359
coated in black. The axial impeller is manufactured from fiber-
reinforced Plastic (PP) with metal core. The impeller is balanced
dynamically in two levels in accordance with DIN ISO 1940 part 1,
quality G6.3.

MTV-1
p. 359

Dimensions

B3

AW sileo oA B B2 B3 B4 ØD1 ØD4 oL

200 EC 260 52 6 127 18 203 7 312


250 EC 320 57 6 132 22 260 7 370
300 EC 380 80 11 157 11 327 9 430
350 EC 435 80 12 157 11 388 9 485
D1

400 EC 490 98 12 175 20 419 9 540


450 EC 535 100 14 209 - 468 11 576
500 EC 615 120 16 181 5 517 11 656
500D EC 615 120 16 181 8 517 11 656
560D EC 675 135 16 208 6 576 11 725
D4

630D EC 750 150 20 287 - 696 11 805


710D-L EC 810 170 20 275 2 772 14.5 850
B2 B4
B
800D EC 910 190 17 267 1 857 14.5 970
A
L 1000D EC 1110 225 20 277 12 1063 14.5 1170

Technical data
AW sileo 200EC 250EC 300EC 350EC 400EC 450EC 500EC 500D EC
Art. no. 35854 35855 35857 35859 35860 35863 35865 35866
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~
Power W 60 83 170 165 140 345 750 980
Current A 0.53 0.72 1.35 1.35 1.15 2.2 3.4 1.6
Max. air flow m3/s 0.278 0.475 0.883 1.04 1.13 1.82 2.57 2.89
R.p.m. min-1 2820 2330 2245 1475 1080 1300 1420 1610
Max. temp. of transported air °C 60 60 60 60 60 60 60 60
Sound pressure level at 1 m dB(A) 57 67 62 58 55 60 67 70
Weight kg 3 3.7 6.1 6.5 8.9 10.5 14.7 16.5
Insulation class, motor B B F B B B B B
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Wiring diagram p. 442-461 50 50 50 50 50 52 54 53
Axial Fans | 203

Quick selection Ventilation


accessories

250 1 AW sileo 200 EC


2 AW sileo 250 EC
3 AW sileo 300 EC
4 AW sileo 350 EC
200 5 AW sileo 400 EC VK p. 389
6 AW sileo 450 EC
7 AW sileo 500 EC

150
Ps [Pa]

SG-AW-D
100 p. 431

Axial fans
50

1 2 3 6 7
4 5
0
0 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000
qv [m³/h]

350 1 AW sileo 500D EC


2 AW sileo 560D EC
3 AW sileo 630D EC
300 4 AW sileo 710D-L EC
5 AW sileo 800D EC
6 AW sileo 1000D EC
250
Ps [Pa]

200

150

100

50
2 3 4 5 6
1

0
5.000 10.000 15.000 20.000 25.000 30.000 35.000
qv [m³/h]

AW sileo 560D EC 630D EC 710D-L EC 800D EC 1000D EC


Art. no. 35867 35872 35876 35879 35899
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 945 3200 2830 2980 2603
Current A 1.5 5 4.3 4.5 4
Max. air flow m3/s 3.18 5.89 6.89 7.76 9.72
R.p.m. min-1 1360 1510 1260 1090 969
Max. temp. of transported air °C 60 65 60 65 70
Sound pressure level at 1 m dB(A) 70 79 78 73 78
Weight kg 21.8 41.8 42.9 52.5 61.2
Insulation class, motor B F B B F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54
Wiring diagram p. 442-461 53 55 55 55 55
204 | Axial Fans

Performance
Q [m³/h] Q [m³/h]
0 300 600 900 0 500 1000 1500 2000
120 160

12988/12989

12987/12990
AW sileo 200EC
AW sileo 250EC
79
90 120

Ps [Pa]
Ps [Pa]

60 80
Axial fans

30 40

67 71
0 0
0 0.1 0.2 0.3 0 0.2 0.4 0.6
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 43 56 63 65 65 67 62 52 LwA Inlet 74 40 57 63 68 67 68 64 55
Measurement point: 0.18 m³/s @ 108 Pa Measurement point: 0.3 m³/s @ 116 Pa

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000
160 100
12297/12991

12299/12992
AW sileo 300EC AW sileo 350EC
79
120 75 73
Ps [Pa]

Ps [Pa]

80 50

40 25

75 75
0 0
0 0.3 0.6 0.9 0 0.3 0.6 0.9 1.2
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 51 59 59 62 63 63 59 53 LwA Inlet 65 45 52 50 56 59 59 57 50
Measurement point: 0.5 m³/s @ 130 Pa Measurement point: 0.671 m³/s @ 86 Pa
Axial Fans | 205

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 0 2000 4000 6000
80 160

12300/12993

12302/12994
AW sileo 400EC AW sileo 450EC

60 71 120 77
Ps [Pa]

Ps [Pa]
40 80

Axial fans
20 40

73 73
0 0
0 0.3 0.6 0.9 1.2 0 0.5 1 1.5 2
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 62 42 46 51 55 58 56 52 41 LwA Inlet 67 48 51 56 60 63 61 58 51
Measurement point: 0.715 m³/s @ 60 Pa Measurement point: 1.1 m³/s @ 118 Pa

Q [m³/h] Q [m³/h]
0 2500 5000 7500 10000 0 3000 6000 9000
200 200

12305/12995
12304/12996

AW sileo 500EC 84 AW sileo 500D EC

150 150
Ps [Pa]

Ps [Pa]

100 100

50 50

81
78 0
0
0 1 2 3 0 1 2 3
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 57 60 62 66 68 69 66 59 LwA Inlet 77 56 61 64 69 71 72 69 63
Measurement point: 1.64 m³/s @ 174 Pa Measurement point: 1.93 m³/s @ 196 Pa
206 | Axial Fans

Q [m³/h] Q [m³/h]
0 3000 6000 9000 12000 0 5000 10000 15000 20000
200 300

12311/12998
12306/12997
83
AW sileo 560D EC AW sileo 630D EC
250

150

200

Ps [Pa]
Ps [Pa]

100 150

100

50
Axial fans

50

78 85
0 0
0 1 2 3 4 0 1 2 3 4 5 6
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 54 60 65 69 72 72 67 62 LwA Inlet 86 60 69 76 80 81 79 75 70
Measurement point: 2.01 m³/s @ 178 Pa Measurement point: 3.75 m³/s @ 285 Pa

Q [m³/h] Q [m³/h]
0 5000 10000 15000 20000 25000 0 10000 20000
250 300

12318/13000
AW sileo 800D EC
12315/12999

AW sileo 710D-L EC
250
200
86
200

150
Ps [Pa]

Ps [Pa]

150

100
100

50
50

81
0 84 0
0 2 4 6 8 0 2 4 6 8
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 85 59 70 76 79 80 78 74 68 LwA Inlet 80 55 63 70 74 75 74 70 65
Measurement point: 4.37 m³/s @ 239 Pa Measurement point: 4.93 m³/s @ 211 Pa
Axial Fans | 207

Q [m³/h]
0 10000 20000 30000
200

12323/12573
AW sileo901000D EC

150
Ps [Pa]

100

50

Axial fans
87
0
0 2.5 5 7.5 10
Q [m³/s]

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 85 61 65 76 80 80 77 75 68
Measurement point: 6.58 m³/s @ 184 Pa
208 | Axial Fans

NEW!
AW sileo Electrical
accessories
• Speed controllable by voltage reduction, plus option of 2-step
operation by D/Y switching for 400V versions
• With inlet guard from sizes 200-630 (as an accessory 710-1000)
• Safe and maintenance free operation
• Electric connection via terminal box mounted on the motor S-ET p. 373
• Single phase fans are supplied with capacitor

Axial fans of the AW sileo range do have a bionic shape of the fan
blade, which reduces the noise level and increases the efficiency
of the fan. AW sileo fans are driven by external rotor motors. The
RTRE/REU
AW range is equipped with a square wall plate, galvanized steel and p. 356
Axial fans

powder coated in black (RAL9005). The protection guard at the inlet


side is powder coated in black. The axial impeller is manufactured
either from pressure die cast aluminum, powder coated in black, or
from high efficiency composite material.
The impeller is balanced dynamically in two levels in accordance REE p. 357
with DIN ISO 1940 part 1, quality G6.3.
The motors are equipped with thermal contacts for motor protec-
tion, with leads to be connected to a TK triggering device, see table
on the next page.
RTRD/RTRDU
Quick selection p. 357

Quick selection also on p. 210

S-DT2 SKT

10187, 9675, 9676, 9677, 9681, 9678, 9680, 9682


9736, 9735, 9740, 9738, 9741, 7004, 10906, 9742

1 AW/AR 200E4 1 AW/AR 350E4


p. 381
2 AW/AR 200E2 2 AW/AR 350DV
3 AW/AR 250E4 3 AW/AR 400E4
4 AW/AR 250E2 4 AW/AR 400DV
5 AW/AR 300E4 5 AW/AR 450DV-K
6 AW/AR 300E2-K 6 AW/AR 450E4-K
7 AW/AR 315DV 7 AW/AR 450E4
8 AW/AR 315E4 8 AW/AR 450DV 7 8

5
AWE-SK
6
3 4 6 p. 372
4
2 1 2

3 5 7 8
1

REV p. 380

Technical data
AW sileo 200 200 250 250 300 300 315 315 350 350 400 400 450 450 450
E4 E2 E4 E2 E4 E2 DV E4 E4 DV E4 DV DV-K E4-K E4
Art. no. 34115 34114 34117 35735 34119 5801 34120 34121 34123 34122 34125 34124 34127 34129 34128
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 230 1~ 230 1~ 400 3~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~
Power W 30 80 50 120 100 309 120 160 170 190 240 230 350 390 550
Current A 0.15 0.38 0.24 0.54 0.41 1.35 0.39 0.67 0.75 0.4 1.1 0.44 0.64 1.75 2.5
Max. air flow m3/s 0.124 0.242 0.273 0.482 0.584 0.948 0.616 0.677 0.91 0.976 1.07 1.08 1.55 1.59 1.98
R.p.m. min-1 1425 2550 1370 2160 1330 2730 1450 1300 1260 1390 1350 1370 1250 1290 1320
Max. temp. of transported air °C 70 60 55 65 60 50 70 50 60 70 65 70 70 55 70
“ when speed controlled °C 70 60 55 65 60 50 70 50 60 70 65 70 70 55 70
Sound pressure level at 1 m dB(A) 46 59 52 66 56 71 62 59 62 64 64 64 66 65 66
Weight kg 3.2 3.2 4 4.2 5 6.6 6.8 6.7 7.5 7.6 8.7 8.7 10.1 10.1 16.2
Insulation class, motor F F F F F B F F F F F F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 55 IP 44 IP 44 IP 54 IP 44 IP 44 IP 54 IP 54 IP 54 IP 44 IP 44 IP 54
Capacitor µF 1 1.5 1.5 3.5 3 8 – 5 5 – 5 – – 7 14
Wiring diagram p. 442-461 49 49 49 49 49 5 18b 49 49 18b 6a 18b 18b 6a 6a
Axial Fans | 209

Dimensions Ventilation
accessories

VK p. 389

Speed control
AW Motor Transformer Thyristor
protection
SG AW
200E2 S-ET RTRE 1.5/REU 1.5 REE 1 p. 431

Axial fans
200E4 S-ET RTRE 1.5/REU 1.5 REE1
250E2 S-ET RTRE 1.5/REU 1.5 REE 1
250E4 S-ET RTRE 1.5/REU 1.5 REE 1
300E2 S-ET RTRE 1.5/REU 1.5 REE 1
SG-AW-D
300E4 S-ET RTRE 1.5/REU 1.5 REE 1 p. 431
315DV STDT RTRD 2/RTRDU 2 -
AW £A B B1 B2 B3 B4 øD1 øD4 £L
315E4 S-ET RTRE 1.5/REU 1.5 REE 1
200 260 46 92 6 142 30 210 7 312
250E2 320 50 102 6 152 30 264 7 370 350DV STDT RTRD 2/RTRDU 2 -
250E4 320 50 97 6 147 30 264 7 370 350E4 S-ET RTRE 1.5/REU 1.5 REE 1
300E2 380 65 111 12 171 46 330 9 430 400DV STDT RTRD 2/RTRDU 2 -
300E4 380 69 103 11 165 28 326 9 430 400E4 S-ET RTRE 1.5/REU 1.5 REE 2
315DV 380 69 118 11 182 19 330 9 430 450DV-K STDT RTRD 2/RTRDU 2 -
315E4 380 63 132 11 173 48 349 9 430 450E4 S-ET RTRE 3/REU 3 REE 4
350DV 435 68 119 12 182 22 388 9 485
450E4-K S-ET RTRE 3/REU 3 REE 2
350E4 435 68 132 12 173 49 390 9 485
500DV STDT RTRD 2/RTRDU 2 -
400 490 88 146 12 182 54 420 9 540
500E4 S-ET RTRE 5/REU 5 REE 4
450DV 535 96 171 14 206 47 480 11 575
450DV-K 535 96 148 14 186 40 480 11 575 560DV STDT RTRD 4/RTRDU 4 –

450E4 535 96 191 14 226 47 480 11 575 560E4 S-ET RTRE 7/REU 7 –
450E4-K 535 96 148 14 186 40 480 11 575 630D4-2 STDT RTRD 4, RTRDU 4 –
500 615 104 204 16 226 62 531 11 655 630DS STDT RTRD 2, RTRDU 2 –
560 675 119 215 16 227 96 589 11 725 630E6 S-ET RTRE 5/REU 5 REE 4
630 750 130 207 20 225 52 664 11 805 710DV STDT RTRD 7/RTRDU 7 –
710DV 810 150 272 20 272 37 763 14.5 850
710DS STDT RTRD 4/RTRDU 4 -
710DS 810 150 246 20 246 37 763 14.5 850
710E6 S-ET RTRE 5/REU 5 REE 4
710E6 810 150 246 20 246 37 763 14.5 850
800DS STDT RTRD 4/RTRDU 4 –
800DS 910 193 284 17 284 34 869 14.5 970
910DS STDT RTRD 7/RTRDU 7
910DS 1010 220 293 20 293 40 922 14.5 1070
1000DS 1110 220 323 20 323 40 1016 14.5 1170 1000DS STDT RTRD 7/RTRDU 7 –

1000DS-L 1110 220 400 20 400 47.5 1067 14.5 1170 1000DS-L STDT RTRD 14 -

AW sileo 450 500 500 560 560 630 630 630 710 710 710 800 910 1000 1000
DV E4 DV DV E4 E6 DS DV E6 DS DV DS DS DS DS-L*
Art. no. 34126 34132 34131 34134 34135 34139 34138 34137 34142 34141 34140 34143 34157 34144 36148
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~ 400 3~ 400 3~ 230 1~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 540 750 770 1044 1150 730 630 2400 950 1000 2600 1600 1950 2700 5597
Current A 1.1 3.35 1.7 2.2 5 3.4 1.25 4.6 4.4 2.5 4.9 3.6 4.4 5.3 10.6
Max. air flow m3/s 2.0 2.48 2.54 3.15 3.03 3.1 3.12 5.23 3.86 4.05 6.27 6.33 7.66 10.1 13.5
R.p.m. min-1 1350 1230 1300 1280 1330 910 900 1318 850 910 1330 920 880 820 889
Max. temp. of transp. air °C 70 70 70 70 70 70 70 65 65 70 60 70 70 70 60
“ when speed controlled °C 70 70 70 70 70 70 70 65 65 70 60 70 70 70 60
Sound pressure level at 1 m dB(A) 67 68 67 74 76 67 64 76 67 66 76 73 72 72 87
Weight kg 14.6 20 20.1 23.5 31.7 26.5 24.5 34.2 35.1 35.1 36.5 53 58.1 69.5 109
Insulation class, motor F F F F F F F F F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF – 16 – – 25 16 – – 16 – – – – – -
Wiring diagram p. 442-461 18b 6a 18b 18b 6a 6a 18b 18b 6a 18b 18b 18b 18b 18b 18b
* Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
210 | Axial Fans

NEW!
AR sileo Electrical
accessories
• Speed controllable by voltage reduction, plus option of 2-step
operation by D/Y switching for 400V versions
• With inlet guard from sizes 200-630 (as an accessory 710-1000)
• Safe and maintenance free operation
• Electric connection via terminal box supplied with the fan S-ET p. 373
• Single phase fans are supplied with capacitor

Axial fans of the AR sileo range do have a bionic shape of the fan
blade, which reduces the noise level and increases the efficiency of
the fan. AR sileo fans are driven by external rotor motors. The AR RTRE/REU
range is equipped with a short casing and flanges according to Eu- p. 356
Axial fans

rovent 1/2, galvanized steel and powder coated in black (RAL9005).


The protection guard at the inlet side is powder coated in black. The
axial impeller is manufactured either from pressure die cast alu-
minum, powder coated in black, or from high efficiency composite
REE p. 357
material.
The impeller is balanced dynamically in two levels in accordance
with DIN ISO 1940 part 1, quality G6.3.
The motors are equipped with thermal contacts for motor protec-
tion, with leads to be connected to a TK triggering device, see table
on the next page. RTRD/RTRDU
p. 357

Quick selection
Quick selection also on p. 208
S-DT2 SKT
p. 381
9684, 9685, 11019, 5339, 9687, 9688, 5343

9747, 9693, 9694, 10904, 10388, 1038


1 AW/AR 500E4 1 AW/AR 710E6
2 AW/AR 500DV 2 AW/AR 710DS
3 AW/AR 560DV 3 AW/AR 710DV
4 AW/AR 560E4 4 AW/AR 800DS
5 AW/AR 630E6,DS 5 AW/AR 910DS
6 AW/AR 630DV 6 AW/AR 1000DS
7 AW/AR 1000DS-L AWE-SK
3 p. 372

2 3 2
4 6
1 4

1 5
5 7
6

REV p. 380

Technical data
AR sileo 200 200 250 250 300 300 315 315 350 350 400 400 450 450 450
E4 E2 E4 E2 E4 E2 DV E4 E4 DV E4 DV DV-K E4-K E4
Art. no. 34458 34457 34460 35734 34462 34461 34464 34463 34465 34466 34468 34470 34474 34472 34471
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 230 1~ 230 1~ 400 3~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~
Power W 30 80 50 120 100 309 120 160 170 190 240 230 350 390 550
Current A 0.15 0.38 0.24 0.54 0.41 1.35 0.616 0.67 0.75 0.4 1.1 0.44 0.64 1.75 2.5
Max. air flow m3/s 0.124 0.242 0.273 0.482 0.584 0.948 0.39 0.677 0.91 0.976 1.07 1.08 1.55 1.59 1.98
R.p.m. min-1 1425 2550 1370 2160 1330 2496 1450 1300 1260 1390 1350 1370 1250 1290 1320
Max. temp. of transported air °C 70 60 55 65 60 50 70 50 60 70 65 70 70 55 70
“ when speed controlled °C 70 60 55 65 60 50 70 50 60 70 65 70 70 55 70
Sound pressure level at 1 m dB(A) 46 59 52 66 56 72 62 59 62 64 64 64 66 65 66
Weight kg 3.2 3.2 4 4.2 5.9 5.3 7.1 6.5 7.5 7.6 8.7 8.7 10.1 10.1 17
Insulation class, motor F F F F F B F F F F F F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 55 IP 44 IP 44 IP 54 IP 44 IP 44 IP 54 IP 54 IP 54 IP 44 IP 44 IP 54
Capacitor µF 1 1.5 1.5 3.5 3 8 – 5 5 – 5 – – 7 14
Wiring diagram p. 442-461 49 49 49 49 49 5 18b 49 49 18b 6a 18b 18b 6a 6a
Axial Fans | 211

Dimensions Ventilation
B A
z xØd
accessories

SG AR/AXC
p. 431
Speed control
Da
DiØ

AW Motor Transformer Thyristor


protection
EV-AR p. 211
200E2 S-ET RTRE 1.5/REU 1.5 REE 1
200E4 S-ET RTRE 1.5/REU 1.5 REE1

Axial fans
250E2 S-ET RTRE 1.5/REU 1.5 REE 1

C
C TK
Ø
250E4 S-ET RTRE 1.5/REU 1.5 REE 1
300E2 S-ET RTRE 1.5/REU 1.5 REE 1
300E4 S-ET RTRE 1.5/REU 1.5 REE 1
GFL-AR
AR sileo A B C ØDi ØDa z x Ød ØTK p. 437
315DV STDT RTRD 2/RTRDU 2 -
200 110 4 84 200 250 4x Ø7 225
315E4 S-ET RTRE 1.5/REU 1.5 REE 1
250E2 110 8 94 257 310 4x Ø9.5 280
250E4 110 8 89 257 310 4x Ø9.5 280 350DV STDT RTRD 2/RTRDU 2 -
MFA-AR
300E2 125 - - 320 382 8x Ø9.5 355 350E4 S-ET RTRE 1.5/REU 1.5 REE 1 p. 432
300E4 135 12 112 306 382 8x Ø9.5 355 400DV STDT RTRD 2/RTRDU 2 -
315E4 135 12 120 316 382 8x Ø9.5 355 400E4 S-ET RTRE 1.5/REU 1.5 REE 2
315DV 135 17 137 316 382 8x Ø9.5 355 450DV-K STDT RTRD 2/RTRDU 2 -
350E4 135 7 125 359 421 8x Ø10 395 450E4 S-ET RTRE 3/REU 3 REE 4
350DV 135 18 136 356 421 8x Ø10 395 450E4-K S-ET RTRE 3/REU 3 REE 2
400 155 16 138 400 480 8x Ø12 450 500DV STDT RTRD 2/RTRDU 2 -
450DV-K 160 19 137 451 530 8x Ø12 500 500E4 S-ET RTRE 5/REU 5 REE 4
450E4 160 18 177 451 530 8x Ø12 500
560DV STDT RTRD 4/RTRDU 4 –
450DV 160 18 157 451 530 8x Ø12 500
560E4 S-ET RTRE 7/REU 7 –
500 166 - 198 503 590 12x Ø12 560
630D4-2 STDT RTRD 4, RTRDU 4 –
560E4 210 25 200 559 650 12x Ø11.5 620
630DS STDT RTRD 2, RTRDU 2 –
560DV 210 19 200 559 650 12x Ø11.5 620
630E6 S-ET RTRE 5/REU 5 REE 4
630E6 220 - 194 634 720 12x Ø11.5 690
710DV STDT RTRD 7/RTRDU 7 –
630DS 220 - 174 634 720 12x Ø11.5 690
630DV 220 24 226 634 720 12x Ø11.5 690 710DS STDT RTRD 4/RTRDU 4 -

710 260 - - 711 800 16x Ø11.5 770 710E6 S-ET RTRE 5/REU 5 REE 4

800 280 - - 797 890 16x Ø11.5 860 800DS STDT RTRD 4/RTRDU 4 –
900 330 - - 914 1005 16x Ø14.5 970 910DS STDT RTRD 7/RTRDU 7
1000 330 - - 1001 1105 16x Ø14.5 1070 1000DS STDT RTRD 7/RTRDU 7 –
1000DS-L 330 44.5 376 1001 1105 24x Ø14.5 1070 1000DS-L STDT RTRD 14 -

AR sileo 450 500 500 560 560 630 630 630 710 710 710 800 910 1000 1000
DV E4 DV DV E4 E6 DS DV E6 DS DV DS DS DS DS-L*
Art. no. 34473 34475 34476 34478 34477 34479 34481 34480 34482 34484 34483 34485 34486 34487 36147

Voltage/Frequency V/50 Hz 400 3~ 230 1~ 400 3~ 400 3~ 230 1~ 230 1~ 400 3~ 400 3~ 230 1~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 540 750 770 1044 1150 730 630 2400 950 1000 2600 1600 1950 2700 5597
Current A 1.1 3.35 1.7 2.2 5 3.4 1.25 4.6 4.4 2.5 4.9 3.6 4.4 5.3 10.6
Max. air flow m3/s 2.0 2.48 2.54 3.15 3.03 3.1 3.12 5.23 3.86 4.05 6.27 6.33 7.66 10.1 13.5
R.p.m. min-1 1350 1230 1300 1280 1330 910 900 1318 850 910 1330 920 880 820 889
Max. temp. of transp. air °C 70 70 70 70 70 70 70 65 65 70 60 70 70 70 60
“ when speed controlled °C 70 70 70 70 70 70 70 65 65 70 60 70 70 70 60
Sound pressure level at 1 m dB(A) 67 68 67 74 76 67 64 76 67 66 76 73 72 72 87
Weight kg 15.4 18.6 18.6 23.2 31.7 25 24.5 34.2 35.2 36.2 38 49.3 60.9 76.9 98
Insulation class, motor F F F F F F F F F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor µF – 16 – – 25 16 – – 16 – – – – – -
Wiring diagram p. 442-461 18b 6a 18b 18b 6a 6a 18b 18b 6a 18b 18b 18b 18b 18b 18b

* Only for use outside the EEA (European Economic Area), see Ecodesign regulation 327/2011
212 | Axial Fans

Performance

AW/AR sileo 200E2


AW/AR sileo 200E4

5
4
3
Axial fans

2
1

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 51 28 39 40 43 47 44 40 30 LwA Inlet 66 36 47 54 56 58 61 59 53
LwA Outlet 51 26 38 41 43 47 44 40 29 LwA Outlet 65 34 46 54 56 58 61 59 52
Measurement point: 0.0894 m³/s @ 26.2 Pa Measurement point: 0.158 m³/s @ 90.6 Pa

AW/AR sileo 250E4 AW/AR sileo 250E2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 59 30 46 48 51 53 54 50 40 LwA Inlet 71 39 50 59 62 64 67 64 55
LwA Outlet 59 29 47 47 50 53 54 49 39 LwA Outlet 71 37 50 60 62 65 67 63 54
Measurement point: 0.196 m³/s @ 31.4 Pa Measurement point: 0.305 m³/s @ 86.5 Pa
Axial Fans | 213

Q [m³/h]
0 1000 2000 3000
200

7004/13091/13094
AW/AR sileo 300E4 175
AW 300E2-K
150

125

Ps [Pa]
100

75 AR 300E2

50

25

Axial fans
0
0 0.2 0.4 0.6 0.8 1

Q [m³/s]

200

W [Pa]
100

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k AW 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 39 48 51 54 55 59 54 42 LwA Inlet/Outlet 78 40 51 61 71 71 73 71 65
LwA Outlet 62 37 48 52 53 55 59 53 41 Measurement point: 0.634 m³/s @ 141 Pa
Measurement point: 0.395 m³/s @ 54.4 Pa AR
LwA Inlet 71 21 39 50 64 66 67 62 54
Measurement point: 0.792 m³/s @ 75 Pa

AW/AR sileo 315DV AW/AR sileo 315E4

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 49 54 53 57 62 64 61 52 LwA Inlet 66 39 55 58 59 60 60 54 44
LwA Outlet 68 47 53 55 58 62 64 61 50 LwA Outlet 66 39 55 58 58 60 60 54 44
Measurement point: 0.368 m³/s @ 73.5 Pa Measurement point: 0.434 m³/s @ 71.8 Pa
214 | Axial Fans

AW/AR sileo 350E4 AW/AR sileo 350DV


Axial fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 65 40 52 53 60 58 60 54 46 LwA Inlet 69 50 53 55 61 64 65 60 53
LwA Outlet 65 39 51 55 58 58 60 53 45 LwA Outlet 70 49 52 56 62 64 65 60 51
Measurement point: 0.553 m³/s @ 79.8 Pa Measurement point: 0.593 m³/s @ 87.8 Pa

AW/AR sileo 400E4 AW/AR sileo 400DV

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 68 48 56 59 60 63 62 57 50 LwA Inlet 69 49 57 58 61 63 63 58 50
LwA Outlet 69 46 56 60 61 65 63 57 48 LwA Outlet 69 47 56 60 61 65 63 58 48
Measurement point: 0.693 m³/s @ 90.4 Pa Measurement point: 0.678 m³/s @ 95.8 Pa
Axial Fans | 215

AW/AR sileo 450E4-K


AW/AR sileo 450DV-K

Axial fans
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 52 64 64 65 67 67 62 54 LwA Inlet 71 53 61 62 64 65 64 60 51
LwA Outlet 73 50 63 64 66 67 66 61 52 LwA Outlet 71 51 60 63 64 66 65 59 52

Measurement point: 0.991 m³/s @ 95.9 Pa Measurement point: 0.916 m³/s @ 104 Pa

AW/AR sileo 450E4


AW/AR sileo 450DV

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 42 53 63 61 64 64 60 52 LwA Inlet 70 47 54 57 62 65 65 60 52
LwA Outlet 69 46 54 62 62 63 63 59 51 LwA Outlet 70 49 55 59 63 65 65 60 51

Measurement point: 1.33 m³/s @ 120 Pa Measurement point: 1.29 m³/s @ 133 Pa
216 | Axial Fans

AW/AR sileo 500DV


AW/AR sileo 500E4
Axial fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 45 59 59 60 67 69 62 51 LwA Inlet 71 43 53 55 60 66 67 62 53
LwA Outlet 72 45 60 60 61 67 68 61 51 LwA Outlet 70 45 53 59 62 65 66 61 52
Measurement point: 1.61 m³/s @ 123 Pa Measurement point: 1.76 m³/s @ 122 Pa

Q [m³/h]
0 2000 4000 6000 8000 10000 12000
250

11736/11740
AW/AR sileo 560E4
AW/AR sileo 560DV 83
200

150
Ps [Pa]

77
100

70
50
63

68 76 81 84
0
0 0.5 1 1.5 2 2.5 3 3.5

Q [m³/s]

2000
P [W]

1000

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 25 46 57 67 75 75 71 60 LwA Inlet 84 31 47 60 70 79 80 76 65
LwA Outlet 79 24 45 58 69 75 75 71 60 LwA Outlet 83 30 48 61 70 78 80 75 65
Measurement point: 2.19 m³/s @ 146 Pa Measurement point: 1.69 m³/s @ 206 Pa
Axial Fans | 217

AW/AR sileo 630E6 AW/AR sileo 630DS

Axial fans
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 48 55 65 65 68 68 61 53 LwA Inlet 71 50 54 58 63 67 66 60 53
LwA Outlet 74 49 56 67 68 70 65 60 53 LwA Outlet 71 50 54 58 63 67 65 60 52
Measurement point: 1.96 m³/s @ 102 Pa Measurement point: 1.8 m³/s @ 111 Pa

0 4000 8000 12000 16000 20000


300
11447/11449

AW/AR sileo 710E6


AW/AR sileo 630DV
250 83

200

77
150

73
100
68

50

1 2 3 4 5
70 75 78 83
0
0 1 2 3 4 5 6

3000
5
2000
[W]

1000 2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 83 36 49 61 71 78 80 74 65 LwA Inlet 74 52 62 65 67 70 68 62 57
LwA Outlet 82 36 51 64 71 78 78 74 65 LwA Outlet 74 52 62 65 67 70 65 61 55
Measurement point: 3.31 m³/s @ 247 Pa Measurement point: 2.49 m³/s @ 114 Pa
218 | Axial Fans

AW/AR sileo 710DV


AW/AR sileo 710DS
Axial fans

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 73 45 55 61 65 69 67 61 52 LwA Inlet 82 51 64 67 72 77 77 73 66
LwA Outlet 72 46 55 61 65 68 64 59 52 LwA Outlet 81 52 64 69 73 76 75 72 66
Measurement point: 2.83 m³/s @ 115 Pa Measurement point: 4.41 m³/s @ 204 Pa

AW/AR sileo 800DS AW/AR sileo 910DS

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 80 50 63 70 73 75 73 68 62 LwA Inlet 79 56 62 72 73 73 71 69 61
LwA Outlet 80 50 63 70 73 75 73 69 62 LwA Outlet 79 57 62 71 74 73 70 68 60
Measurement point: 4.68 m³/s @ 115 Pa Measurement point: 5.01 m³/s @ 144 Pa
Axial Fans | 219

AW/AR sileo 1000DS AW/AR sileo 1000DS-L

Axial fans
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 79 58 63 71 72 74 72 68 64 LwA Inlet 92 34 54 74 82 87 88 86 76
LwA Outlet 79 58 63 71 73 74 70 67 64 LwA Outlet 93 36 57 75 83 88 88 87 78
Measurement point: 6.31 m3/s @ 149 Pa Measurement point: 8.71 m3/s @ 241 Pa
220 | Axial Fans

AXC Electrical
accessories
• Aerofoil impeller with adjustable pitch angle for maximum
efficiency
• D ie cast aluminium hub and blades
• Long casing, hot dip galvanized steel, to DIN EN ISO 1461; AXC-E
versions with pre-galvanized casing REV p. 380
• Spun flanges for high rigidity, according to Eurovent 1/2
• IP65 rated terminal box mounted at the outside of the casing for
easy wiring
• Three-phase motors IP55, insulation class F, in accordance with EN
60034-5/IEC 85 and IEC 60034-30 FRQ p. 361
Axial fans

• Suitable for operating temperatures of up to 55°C


• Truly reversible version AXR on request
IE2 • 60 Hz range available
2009/640/EG
• Inspection hole to verify correct direction of rotation

The Systemair AXC range of long cased medium pressure axial fans
is available in sizes from 315 up to 2000 mm impeller diameter. The
adjustable pitch angle setting offers a wide performance and maxi-
mum flexibility to match precisely individual airflow requirements.
This catalogue gives an overview up to size 1250. Other sizes and
configurations are available from our online selection software.
The AXC axial fans have been performance tested in accordance
with DIN ISO 5801, DIN 24163 and AMCA 210-07 on the Systemair
fan test rig. The IE2 three phase motors are equipped with PTC ther-
mistors for optimum motor protection. The motor is speed controlla-
Dimensions ble by frequency converter.

AXC øDi øDa øTk ød L hF E K


315 315 395 355 8x10 375 235 265 310
355 355 435 395 8x10 375 250 305 310
400 400 480 450 8x12 450 280 350 385
450 450 530 500 8x12 500 315 400 435
500 500 590 560 12x12 540 335 440 464
560 560 650 620 12x12 500/750 375 500 424/674
630 630 720 690 12x12 500/750 425 570 424/674
710 710 800 770 16x12 500/700/800 450 650 424/624/722
800 800 890 860 16x12 500/700 530 730 414/614
900 900 1005 970 16x15 640/850 560 830 552/762
1000 1000 1105 1070 16x15 640/850 670 930 552/762
1120 1120 1260 1190 20x15 700/1000 710 1030 612/910
1250 1250 1390 1320 20x15 850/1050 800 1180 740/938
1400 1400 1540 1470 20x15 950/1360 900 1300 820/1228
1600 1600 1740 1680 24x19 950/1360 1000 1500 800/1208
* Dimensions L+K depending on motor size
Axial Fans | 221

Axial Fans AXC Ventilation


accessories
High efficiency impellers Multi stage fans
The AXC die cast aerofoil aluminium im- For higher pressure drops
pellers can be offered with full or frac- two stage fans are offered.
tional solidities, maximum efficiencies can Two fans in series increase
ESD-F p. 438
be obtained. Different impeller/hub con- the available static pressure
figurations allow high pressure drops. AXR drop.
impellers are truly reversible.
Quality EV-AXC
Sturdy casing Systemair is ISO 9001 ap-
p. 221
AXC/AXR axial fan casings are heavy proved. The Systemair qual-
gauge, hot dip galvanized, with spun ity is regularly monitored by two stage fan

Axial fans
flanges for high rigidity. AXC-E casings are TÜV Süd.
pre-galvanized. Long cased execution as FSD p. 433
standard stock range. Also available with
short casing and with an acoustically insu- Performance curves and technical details
lated box. for the required fan duties are available
from our online selection software, which GFL-AXC
Motors can be downloaded or used online from p. 437

The built-in motors are equipped with PTC our homepage: www.systemair.com. You
thermistors for optimum motor protection. can, of course, also order it directly from
Single or two speed motors. Speed con- our customer support.
LRK(F)
trollable by frequency converter. p. 430
Efficiency class IE2 as per 2009/640/EC
guidelines.
MFA-AXC
p. 432

Acoustic data of the AXC series


RSA p. 430
The human ear perceives tones and intensity based on Example
sound pressure levels. To consider this fact frequency Calculation of an octave band for:
weighting curves were established. In technical acoustics Operating point: 6000 m³/h at 115 Pa static
the A-weighting is most common. The level values in the Fan model: AXC 500-10 50 Hz 1440 rpm SD p. 433
diagrams are A-weighted. They correspond to the sound
power levels of a fan emitted on pressure side in a duct. Result
The calculation gives a duct emission level Lw4 of 78 dB(A).
According to EN 25136 = LW4 in dB(A). LWA oct = LWA4 - Lcorrection MP p. 432

The catalogue values can be expected, if the flow condi- AXC 500-10 50Hz 1440 rpm
tions of the fan correspond to those which are adequate qv [m³/h]
0 2000 4000 6000 8000 10000 12000
according to standard when installing the fan. When in- 200
Ps [Pa]

10° 15°
Lw dB(A)
adequately installed or operated incorrectly, the fan can
30° 35° SG p. 431
produce much more noise than necessary for the venti- 25°
20°
lation task. 150
40°
The fan sound level which is emitted into the duct is 76 78 80 83 84 dB(A)

important for the selection of the right duct silencers.


100
The efficiency of silencers depends on the frequency. A 76 78 80 82 84 dB(A) ZSD p. 433
division of the frequency into bands with the width of an
octave is sufficient in ventilation technology.
50
The following example shows how to calculate a spec- 76 78 80 82 83 dB(A)
trum from the total sound power level.
Pd
Table 1 shows the correction values in the different MPR p. 431
0
frequencies of the mid octave band. 1 2 3
qv [m³/s]

Mid octave band frequency Hz 63 125 250 500 1k 2k 4k 8k


Lcorrection dB 7 7 6 7 10 14 18 23
Table 1: Correction values dependent on the frequency

Mid octave band frequency Hz 63 125 250 500 1k 2k 4k 8k


Lw oct dB(A) 72 72 73 72 69 65 61 56
Table 2: Level values of the fan in the octave band
222 | Axial Fans

Performance

0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000 7000 8000 9000
300 700

AXC 315-10 2-pole


250 600 AXC 355-10 2-pole

500
200

400
150
300
100
200
Axial fans

50
100

0 0
1 1 2

1.2
1.0 1.6
0.8
P [kW]

1.2

P [kW]
0.6 0.8
0.4
0.2 0.4
0 0

Item no. Size* Item no. Size*


CAX3152001 AXC 315-10-2 (0.75 kW) CAX3552001 AXC 355-10-2 (0.75 kW)
CAX3152002 AXC 315-10-2 (1.1 kW) CAX3552002 AXC 355-10-2 (1.1 kW)
CAX3152003 AXC 315-10-2 (1.5 kW) CAX3552003 AXC 355-10-2 (1.5 kW)
CAX3552004 AXC 355-10-2 (2.2 kW)

0 2000 4000 6000 8000 10000 12000 14000 2000 6000 10000 14000 18000
700 700

AXC 400-10 2-pole AXC 450-10 2-pole


600 600

500 500

400 400

300 300

200 200

100 100

0 0
1 2 3 1 2 3 4 5

4 6,0
3
4,0
P [kW]

P [kW]

2
2,0
1

0 0

Item no. Size* Item no. Size*


CAX4002001 AXC 400-10-2 (0.75 kW) CAX4502001 AXC 450-10-2 (1.1 kW)
CAX4002002 AXC 400-10-2 (1.1 kW) CAX4502002 AXC 450-10-2 (1.5 kW)
CAX4002003 AXC 400-10-2 (1.5 kW) CAX4502003 AXC 450-10-2 (2.2 kW)
CAX4002004 AXC 400-10-2 (2.2 kW) CAX4502004 AXC 450-10-2 (3.0 kW)
CAX4002005 AXC 400-10-2 (3.0 kW) CAX4502005 AXC 450-10-2 (4.0 kW)

* More sizes available on request


Axial Fans | 223

0 5000 10000 15000 20000 25000 30000 5000 10000 15000 20000 25000 30000
900 1000

800 AXC 500-10 2-pole 900 AXC 560-9 2-pole

700 800

700
600
600
500
500
400
400
300
300

Axial fans
200
200
100 100

0 0
1 2 3 4 5 6 7 8 2 3 4 5 6 7 8

10 12

8
P [kW]

P [kW]
5
4

0 0
Item no. Size* Item no. Size*
CAX5002001 AXC 500-10-2 (1.1 kW) CAX5602019 AXC 560-9-2 (1.1 kW)
CAX5002002 AXC 500-10-2 (1.5 kW) CAX5602020 AXC 560-9-2 (1.5 kW)
CAX5002003 AXC 500-10-2 (2.2 kW) CAX5602021 AXC 560-9-2 (2.2 kW)
CAX5002004 AXC 500-10-2 (3.0 kW) CAX5602022 AXC 560-9-2 (3.0 kW)
CAX5002005 AXC 500-10-2 (4.0 kW) CAX5602023 AXC 560-9-2 (4.0 kW)
CAX5602024 AXC 560-9-2 (5.5 kW)
CAX5602025 AXC 560-9-2 (7.5 kW)
CAX5602026 AXC 560-9-2 (11 kW)
10000 20000 30000 40000 CAX5602027 AXC 560-9-2 (15 kW)
1400

1200 AXC 630-9 2-pole


4000 8000 12000 16000 20000
300
1000
AXC 630-9 4-pole
800 250

600 200

400
150

200
100

0
5 10 50

20 0
16 2 3 4 5 6
12
P [kW]

2.5
8
2.0
4
P [kW]

1.5
0
1.0
Item no. Size* 0.5
CAX6302017 AXC 630-9-2 (2.2 kW) 0
CAX6302018 AXC 630-9-2 (3 kW)
CAX6302019 AXC 630-9-2 (4 kW) Item no. Size*
CAX6302020 AXC 630-9-2 (5.5 kW) CAX6304005 AXC 630-9-4 (2.2 kW)
CAX6302021 AXC 630-9-2 (7.5 kW) CAX6304006 AXC 630-9-4 (3 kW)
CAX6302022 AXC 630-9-2 (11 kW)
CAX6302023 AXC 630-9-2 (15 kW)
CAX6302024 AXC 630-9-2 (18.5 kW)
224 | Axial Fans

0 5000 10000 15000 20000 25000 30000 10000 20000 30000 40000
450 600

400 AXC 710-9 4-pole AXC 800-9 4-pole


500
350

300 400

250
300
200

150 200

100
Axial fans

100
50

0 0
1 2 3 4 5 6 7 8 5 10

5 9
4

P [kW]
6
P [kW]

3
2
3
1
0 0

Item no. Size* Item no. Size*


CAX7104007 AXC 710-9-4 (2.2 kW) CAX8004011 AXC 800-9-4 (2.2 kW)
CAX7104008 AXC 710-9-4 (3 kW) CAX8004012 AXC 800-9-4 (3 kW)
CAX7104008 AXC 710-9-4 (4 kW) CAX8004013 AXC 800-9-4 (4 kW)
CAX7104012 AXC 710-9-4 (5.5 kW) CAX8004014 AXC 800-9-4 (5.5 kW)
CAX8004015 AXC 800-9-4 (7.5 kW)

5000 15000 25000 35000 45000 55000 65000 20000 40000 60000 80000
700 900
AXC 1000-10 4-pole
800
600
AXC 900-10 4-pole 700
500
600
400
500

300 400

300
200
200
100
100

0 0
5 10 15 5 10

16 30,0
12
P [kW]

P [kW]

20,0
8

4 10,0

0
0

Item no. Size* Item no. Size*


CAX9004008 AXC 900-10-4 (2.2 kW) CAX10004007 AXC 1000-10-4 (4 kW)
CAX9004009 AXC 900-10-4 (3 kW) CAX10004008 AXC 1000-10-4 (5.5 kW)
CAX9004010 AXC 900-10-4 (4 kW) CAX1000409 AXC 1000-10-4 (7.7 kW)
CAX9004011 AXC 900-10-4 (5.5 kW) CAX10004010 AXC 1000-10-4 (11 kW)
CAX9004012 AXC 900-10-4 (7.5 kW) CAX10004011 AXC 1000-10-4 (15 kW)
CAX9004013 AXC 900-10-4 (11 kW) CAX10004012 AXC 1000-10-4 (18.5 kW)
CAX9004014 AXC 900-10-4 (15 kW) CAX10004013 AXC 1000-10-4 (22 kW)
CAX10004014 AXC 1000-10-4 (30 kW)
Axial Fans | 225

Q [m³/h]
20000 40000 60000 80000 100000 120000 140000 20000 60000 10000 14000 180000
1000 1400
900 AXC 1120-10 4-pole AXC 1250-12 4-pole
28 32 36
24 1200
800 116 dB(A)
20 114
16
700 12 112 1000
Ps [Pa]

600 109
800
500 116 dB(A)
114
111 600
400
108
300 400

Axial fans
200
200
100 110 113 115 dB(A)
107

0 0
10 20 30 10 20 30 40 50

60 36
50 32
80
P [kW]

40

P [kW]
28
60
24
30 20
20 16 40
12
10 20
0
0

Item no. Size* Item no. Size*


CAX11204006 AXC 1120-10-4 (5.5 kW) CAX12504007 AXC 1250-12-4 (11 kW)
CAX11204007 AXC 1120-10-4 (7.5 kW) CAX12504008 AXC 1250-12-4 (15 kW)
CAX11204008 AXC 1120-10-4 (11 kW) CAX12504009 AXC 1250-12-4 (18.5 kW)
CAX11204009 AXC 1120-10-4 (15 kW) CAX12504010 AXC 1250-12-4 (22 kW)
CAX11204010 AXC 1120-10-4 (18.5 kW) CAX12504011 AXC 1250-12-4 (30 kW)
CAX12504012 AXC 1250-12-4 (37 kW)
CAX12504013 AXC 1250-12-4 (45 kW)
CAX12504014 AXC 1250-12-4 (55 kW)

* More sizes available on request


226 | Axial Fans

AXCBF Electrical
accessories
• Aerofoil impeller with adjustable pitch angle.
• Die cast aluminium hub and blades.
• Bifurcated casing, hot dip galvanized steel, to EN ISO 1461
flange holes according Eurovent 1/2.
• Three phase motors, IP55, insulation class F, REV p. 380
in accordance with EN 60034-5, IEC 85.
• Terminal box mounted directly onto the IE2 motor
• Suitable for operating temperatures of up to 200°C continuously
• Inspection hole to verify correct direction of rotation.

The Systemair AXCBF range of bifurcated medium pressure axial

IE2
Axial fans

fans has been developed for applications with an atmosphere which


would either require special motors or reduce the lifetime of a stand-
2009/640/EG
200°C ard motor.
The motors of AXCBF are outside the airstream. Available in sizes
from 250 up to 800 mm impeller diameter. AXCBF bifurcated axial
fan casings are heavy gauge, hot dip galvanized. The motor com-
partment allows easy access to the motor terminal box for wir-
ing. Three phase B3 foot mounted motors, totally enclosed and fan
cooled. The three phase motors are equipped with PTC thermistors
for optimum motor protection.

Quick selection
7561, 7571, 7574, 7576, 7579

7594, 7580, 7581, 7583, 7584


1 AXCBF 400D4-32
1 AXCBF 250D2-32
2 AXCBF 500D2-20
2 AXCBF 250D4-32
3 AXCBF 500D4-32
3 AXCBF 315D2-30
4 AXCBF 630D4-26
4 AXCBF 315D4-32
5 AXCBF 800D4-18
5 AXCBF 400D2-22

4 1 3 5
1 3 4 2 5

Technical data
AXCBF 250D4-32 250D2-32 315D4-32 315D2-30 IE2 400D4-32
Art. no. 32458 32456 32462 34146 32483
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 250 370 250 750 550
Rated current A 0.8 1.8 0.8 1.68 1.5
Max. air flow m3/s 0.23 0.49 0.54 0.951 1.00
R.p.m. min-1 1487 2929 1466 2875 1445
Max. temp. of transported air °C 200 200 200 200 200
Permitted max embient temp. °C 55 55 55 55 55
Weight kg 30 30 32 35 42
Insulation class, motor F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 17a 17a 17a 17a 17a
Axial Fans | 227

Dimensions Ventilation
accessories
A
G

I
øH
MFA-AXCBF
p. 432
øC
øD
øB

EVH p. 436
øF

Axial fans
AXCBF A øB øC øD øF G øH I
250 535 448 328 250 280 45° 10 4x90°
FSD p. 433
315 535 452 385 315 355 22.5° 10 8x45°
400 625 585 480 400 450 22.5° 10 8x45°
500 long version 710 695 590 500 560 15° 12 12x30°
500 short version 660 695 590 500 560 15° 12 12x30°

GFL-AR/AXC
A G p. 437
I

øH

SG AR/AXC
øC
øB

p. 431

øE RSA p. 430

AXCBF A øB øC øE G øH I
630 790 728 630 690 15° 12 12x30°
800 880 890 800 860 11.25° 12 16x22.5°

Note: Accessories RSA


and SG not available
for size 250

AXCBF 400D2-22 IE2 500D2-20 IE2 500D4-32 IE2 630D4-26 IE2 800D4-18 IE2
Art. no. 34147 34148 34152 34155 34156
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 2200 4000 1100 2200 4000
Current A 4.48 7.64 2.53 4.64 8.12
Max. air flow m3/s 1.65 3.06 1.91 3.44 5.63
R.p.m. min-1 2890 2914 1445 1440 1445
Max. temp. of transported air °C 200 200 200 200 200
Permitted max embient temp. °C 55 55 55 55 55
Weight kg 49 87 66 106 155
Insulation class, motor F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 17a 17b 17a 17a 17b

34148 = long version 34152 = short version


228 | Axial Fans

Performance
Axial fans

AXCBF 315D2-30 IE2

AXCBF 400D2-22 IE2


Axial Fans | 229

AXCBF 500D4-32 IE2 AXCBF 500D2-20 IE2

Axial fans
230 | Explosion Proof Fans

Explosion Proof Fans


proof fans
Explosion

Selection of an explosion proof fan


The system user is responsible for the project. The categories or zones do All Systemair explosion proof fans
the correct system design for a not define the concentration! correspond with category 2, allowing an
proper operation. Manufacturers are application in zone I and zone 2.
Category 1 (zone 0) covers areas,
responsible only for the appearance Pre-selection depends on the medium
where there is a permanent or long
and workmanship of the supplied to be transported. Each medium has
lasting occurrence of explosion
components. an individual ignition temperature.
hazardous atmosphere (more than
Systemair explosion proof fans comply
1.000 h/year). Example: Inside a fuel
In the industry explosion hazardous with temperature classification T3,
tank.
areas are classified in zones. ATEX some units can also be used in T4.
classifies the fans in categories, corre- Category 2 (zone 1) covers areas, The following table shows possible
sponding to the zones. Categories are where there is a regular occurence of temperature classifications.
independent from the substance causing explosion hazardous atmosphere (10 – Temperature Ignition temp. Max. surface
the explosion hazard. The classification 1.000 h/year). Example: Filling machine. classification of different gas temp. of electri-
in categories (or zones) is related to mixtures cal equipment
Category 3 (zone 2) covers areas,
the temporal appearance (frequency T1 > 450 °C 450 °C
where there is a non-regular or short
of occurence) of explosion hazardous T2 > 300...> 450 °C 300 °C
time appearance of explosion hazardous T3 > 200...> 300 °C 200 °C
atmosphere. Basically the correct zone or
atmosphere (up to 10 h/year). Example: T4 > 135...> 200 °C 135 °C
category can only be given by the user
defective gas pipe, accidents. T5 > 100...> 135 °C 100 °C
of the system, after having conducted
T6 > 85...> 100 °C 85 °C
an analyse regarding the occurence of
explosion hazardous gases or mixtures in

General Systemair ranges Motors


Systemair explosion proof fans have been The materials used in Systemair EX fans DVEX, AW-EX, KTEX, RVK, PRF-EX (Ex e) and
developed to be used in effective supply are in accordance with DIN EN 60079. DKEX are equipped with speed controllable,
and exhaust air systems allocated to The fans of series DVEX, DVV-Ex and certified external rotor motors in Ex e
category 2 (zone 1) and category 3 (zone RVK-Ex are equipped with self-cleaning execution. EX is equipped with non speed
2) in explosion hazardous areas. impellers with backward curved blades. controllable IEC motors, Ex e execution. DVV-
All fans are manufactured in accordance EX, KTEX and DKEX are equipped with EX, AXC-EX, AXCBF-EX and PRF-EX (Ex d) is
with ATEX guideline 94/9/EG certified impellers with forward curved blades. equipped with either single or two speed
for EC countries. Certificates can be AW-EX is equipped with profiled steel motors in Ex d. This motor type can be speed
downloaded from our homepage. axial impellers with additional painting. controlled by frequency.
The fans are suitable for mounting in All DVEX, KTEX, DKEX, AW-EX, AXC-EX,
above mentioned explosion hazardous AXCBF-EX and RVK EX and DVV-EX fan
zones, for extraction of gases. motors are equipped with a cold conductor
for motor protection. The motor protection
has to be connected with a PTC triggering
device, described in the certificate and also
certified. Motors of series EX do not have a
thermal motor protection. Those motors have
to be monitored by a suitable over-current
device.
Explosion Proof Fans | 231

Labelling of an ATEX approved fan:

Equipment group Category


Notified body Classification EPL = Equipment protection level
(Quality assurance system) G=gas, D=dust

CE 0820 II 2G c Ex e IIB T3 Gb Sira 07ATEX 6341 X


CE labelling Ignition proctection class Temperature class ATEX certification no.
Group

The ignition temperature of the The last decision has to be made


i intrinsic safety
medium, but also the classification regarding the types of protection.

proof fans
Explosion
in explosion groups is important. Explosion proof fans from Systemair c* constructional safety

Explosion proof fans from Systemair correspond to types of protection Ex e d* flameproof enclosure
are approved (according to type) for (except DVV-EX, AXC-EX, AXCBF-EX and e* increased safety Ex d IIC T4
the transportation of substances PRF-EX (Ex d), these are related to types
p pressurized
corresponding to explosion group IIA, of protection Ex d = pressure resistant
o oil immersion
IIB and IIC. capsulation). The types of protection
always refer to the installed explosion m encapsulation
Group Gases an vapours of substances
proof motor (except c, it refers to the q powder filling
IIA acetone, ammonia, ethyl alcohol,
mechanic construction). The following nA* non sparking
fuel, benzene, methane, pro-
types of protection may be requested:
pane, carbon dioxide * in the Systemair range

IIB ethylene, town gas, diethyl ether


IIC hydrogen, carbon disulphide,
acetylene
Table relates to ATEX classifications

All explosion proof fans according to ATEX guideline 94/9/EG (II 2 G)


RVK-EX 232 KTEX 238 DVV-EX 250

Circular duct fan Rectangular duct fan Roof fan

EX 234 DKEX 242 AW-EX 254

Centrifugal fan Centrifugal fan Axial wall fan

DVEX 246 AXC-EX / AXCBF-EX 258

Roof fan Axial fan


232 | Explosion Proof Fans

RVK 315Y4 Electrical


accessories
• In accordance with ATEX directive 94/9/EC
• Speed controllable
• Can be installed in any position
• Motor protection over cold conductor
U-EK 230E EX
p. 374
The RVK fans are designed for installation in ducts. The fans have
backward curved blades and external rotor motors.
The RVK 315 Y4 can be controlled by reducing voltage via 5-step
controller in combination with the Systemair Standard tripping unit
U-EK230E EX. The fans are supplied with flying leads.
The RVK 315Y4 fan complies with the ATEX regulation. The fans
R-DK4 KT
can be used for zone 1 and zone 2; Field of application II, for gases
p. 360
of groups IIA and IIB, temperature class T1, T2 and T3. The casing is
made from conducting plastic. Explosion proof version complies with
EN 60079-0, EN 60079-7, EN 14986, EN 13463-1 and EN 13463-5.
Improved safety in accordance with Ex e IIB T3.
EX e p. 380
proof fans

Note: PTC triggering device U-EK230E EX must always be connected.


Explosion

RTRD p. 357

The explosion proof terminal box REV ATEX


is supplied as an accessory to the p. 381
RVK 315Y4, ordered separately.

Technical data
RVK 315Y4
Art. no. 30271
Voltage/Frequency V/50 Hz 400 3~
Power W 90
Current A 0.25
Max. air flow m3/s 0.311
R.p.m. min-1 1385
Max. temp. of transported air °C 40
“ when speed controlled °C 40
Sound pressure level at 3 m dB(A) 41.2
Weight kg 7.1
Insulation class, motor B
Enclosure class, motor IP 44
Motor protection U-EK230E EX
Certificate ZELM 03ATEX0198X
Explosion proof classification acc. to ATEX II 2G c Ex e IIB T3
Wiring diagram p. 442-461 43
Explosion Proof Fans | 233

Dimensions Ventilation
accessories
225

FK p. 388
200
60

SG p. 389

314 LDC p. 390

405 FFR p. 391

proof fans
Explosion
264
IGC p. 388
30,5

314
VK p. 389

Performance

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 44 61 62 61 58 55 54 45
LwA Outlet 68 49 61 62 60 60 57 55 45
LwA Surrounding 48 18 27 36 44 44 39 34 25
Measurement point: 0.172 m³/s @ 145 Pa
234 | Explosion Proof Fans

EX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Suitable for use in battery-charging rooms, fume cupboards and
similar environments
• Compact design
MSEX p. 373
EX fans can be installed in any position, and their compact design
makes them easy to install.
These fans are powered by specially manufactured EX motors,
and have impellers with forward-curved blades. The fan casing is
cast in silumin, and the impeller is manufactured from aluminium.
REV ATEX
The single-phase fans have a capacitor enclosed in sand, which is
p. 381
approved for EX certification.
Explosion proof versions comply with EN 50014, EN 50017, EN
50019, EN 1127- and EN 13463-1. Improved safety in accordance
with Ex e q IIB T3.

Note! EX 140-180 fans are not speed controllable. PTC triggering


proof fans

device MSEX has to be used in accordance to ATEX certificate.


Explosion

Quick selection
3960, 3992, 3962, 3991, 3967, 3965

1 EX 140-4C, 140-4 3 EX 140-2


2 EX 140-2C 4 EX 180-4C
5 EX 180-4
3
2

1 5 4

Technical data
EX 140-4C 140-2C 140-4 140-2 180-4C 180-4
Art no. 1557 1559 1560 1562 1558 1561
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 400 3~ 400 3~ 230 1~ 400 3~
Power W 113 674 131 696 185 188
Current A 0.63 3.00 0.38 1.28 0.91 0.43
Max air flow m3/s 0.154 0.326 0.162 0.327 0.236 0.217
R.p.m. min-1 1465 2885 1465 2890 1415 1435
Temperature range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Sound pressure level at 3 m dB(A) 42.7 49.1 41.3 47.4 41.2 41.9
Weight kg 7.5 9.3 6.7 8.5 7.8 7
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
Capacitor 8 25 – – 8 –
Motor protection MSEX 0.4-0.63 MSEX 2.5-4.0 MSEX 0.25-0.4 MSEX 1.0-1.6 MSEX 0.63-1.0 MSEX 0.4-1.0
Certificate SP 03ATEX3103X
Explosion proof classification acc. to ATEX II 2G Ex e q IIB T3
Wiring diagram p. 442-461 9 9 10 10 9 10
Explosion Proof Fans | 235

Dimensions Ventilation
accessories
F
C L
B K

I
BS p. 435
øG(4x)
D
E

FKX p. 435

H
49
8/ ø1 94
ø11 /ø1
58
ø1 IS p. 434
HC

proof fans
Explosion
US p. 434

EX A B C D E F øG H I K L M VK p. 389
140-2 92 94 115 105 120 130 6 261 – 103 226 285
140-2C 92 94 115 105 120 130 6 261 50 103 226 285
140-4 92 94 115 105 120 130 6 261 – 103 226 255
140-4C 92 94 115 105 120 130 6 261 50 103 226 255
180-4 109 86 110 120 140 125 7 294 – 120 261 255
180-4C 109 86 110 120 140 125 7 294 50 120 261 255
236 | Explosion Proof Fans

Performance
proof fans
Explosion

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 59 23 38 47 52 55 52 46 36 LwA Inlet 72 34 52 62 62 66 69 63 57
LwA Outlet 67 45 54 60 63 61 55 49 42 LwA Outlet 79 63 66 72 73 72 73 65 61
LwA Surrounding 50 19 22 31 43 43 46 41 32 LwA Surrounding 56 22 34 42 50 48 52 47 43
Measurement point: 0.0878 m³/s @ 135 Pa Measurement point: 0.161 m³/s @ 645 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 60 23 42 50 50 58 50 44 35 LwA Inlet 72 32 50 62 62 66 67 62 57
LwA Outlet 65 43 57 58 59 59 52 46 39 LwA Outlet 78 63 67 72 73 71 70 63 59
LwA Surrounding 48 13 23 37 40 43 43 41 32 LwA Surrounding 54 21 31 42 47 47 50 46 42
Measurement point: 0.0786 m³/s @ 141 Pa Measurement point: 0.15 m³/s @ 653 Pa
Explosion Proof Fans | 237

proof fans
Explosion
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 62 24 41 52 54 58 54 50 45 LwA Inlet 62 24 47 56 54 58 54 49 42
LwA Outlet 67 47 57 60 61 64 54 50 42 LwA Outlet 70 52 63 65 63 61 54 48 42
LwA Surrounding 48 23 25 32 43 44 40 37 31 LwA Surrounding 49 13 30 36 43 45 42 37 29
Measurement point: 0.104 m³/s @ 232 Pa Measurement point: 0.102 m³/s @ 200 Pa
238 | Explosion Proof Fans

KTEX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Speed controllable
• Integral thermistors (PTC*)
• Maintenance-free and reliable
U-EK 230E EX
p. 374
KTEX fans can be installed in any position and are easy to connect
using the DS-EX flexible connections. These fans have impellers with
forward-curved blades and external rotor motors. The casing is
manufactured from galvanised sheet steel, with a copper inlet cone.
To protect the motor from overheating, PTC protective circuits in
the motors must be connected to a PTC triggering device certified
R-DK4 KT
according to Directive 94/9/EC that isolates the motor from voltage p. 360
supply immediately when activated. We recommend to use
U-EK230E for motor protection.
Explosion proof versions comply with EN 60079-0:2009, EN
14986:2007, EN 60079-7:2007. Improved safety in accordance with
Ex e IIB+H2 T3 Gb.
proof fans
Explosion

* Positive Temperature Coefficient RTRD p. 357

Quick selection
3750, 3752, 3756, 4234, 4245

1 KTEX 50-25-4 RTRDU


2 KTEX 50-30-4 p. 357
3 KTEX 60-30-4
4 KTEX 60-35-4
5 KTEX 70-40-6

Ex e p. 380

1 2 3 4 5 REV ATEX
Min. static pressure as per dotted line. p. 381
Min. airflow 0.055 m³/s.

Technical data
KTEX 50-25-4 50-30-4 60-30-4 60-35-4 70-40-6
Art. no. 19402 19404 19406 19960 19961
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 490 900 1300 2100 1800
Current A 0.85 1.80 2.20 3.90 3.70
Max. air flow m3/s 0.426 0.653 0.82 1.01 1.37
R.p.m. min-1 1290 1355 1330 1380 840
Min. static back pressure Pa 90 140 225 220 -
Temperature range, ambient and duct °C -20... +40 -20... +40 -20... +40 -20... +40 -20... +40
Sound pressure level at 3 m dB(A) 56.5 58 58 61.8 54.8
Weight kg 17 22.5 30.5 35.5 48
Insulation class, motor F F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection U-EK230E EX U-EK230E EX U-EK230E EX U-EK230E EX U-EK230E EX
Certificate SP 12ATEX3164X
Explosion proof classification acc. to ATEX II 2G Ex e IIB+H2 T3 Gb
Speed control, five step Transformer RTRD 2* RTRD 4* RTRD 4* RTRD 7* RTRD 4*
Speed control, five step high/low Transformer RTRDU 2* RTRDU 4* RTRDU 4* RTRDU 7* RTRDU 4*
Wiring diagram p. 442-461 11a 11a 11a 11a 11a
* + U-EK230E EX
Explosion Proof Fans | 239

Dimensions Ventilation
accessories
E
D 8.0
A (inside)

H*

I**
B (inside)

DS-EX
C
F

p. 434

Ø10(8x)

FFK p. 401

LDR p. 400
G

H* = Dimensions from the engine bolts

proof fans
Explosion
I** = Dimension with fully open hatch.
GFL p. 399

KTEX A B C D E F G H I
50-25-4 498 248 270 520 540 290 532 34.5 610
50-30-4 498 298 320 520 540 340 562 34.5 695
60-30-4 598 298 320 620 640 340 642 52 715
60-35-4 598 348 370 620 640 390 717 54.5 805
70-40-6 698 348 420 720 740 440 787 50 900
240 | Explosion Proof Fans

Performance
proof fans
Explosion

Min. static pressure 90 Pa Min. static pressure 140 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 55 66 66 61 62 63 61 58 LwA Inlet 73 54 65 64 63 67 67 65 61
LwA Outlet 72 46 60 64 66 67 64 62 58 LwA Outlet 79 48 62 67 70 74 71 70 65
LwA Surrounding 64 57 59 57 53 53 50 46 43 LwA Surrounding 65 54 56 61 55 58 53 49 46
With LDR 50-25 With LDR 50-30
LwA Inlet 60 55 56 51 36 37 43 46 46 LwA Inlet 61 54 57 49 43 36 50 51 50

Measurement point: 0.288 m³/s @ 259 Pa Measurement point: 0.351 m³/s @ 375 Pa

Min. static pressure 225 Pa Min. static pressure 220 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 57 66 63 64 68 68 66 63 LwA Inlet 78 59 67 66 66 69 71 74 70
LwA Outlet 89 60 70 75 80 84 83 82 77 LwA Outlet 85 54 68 71 77 78 77 80 75
LwA Surrounding 65 55 60 57 55 56 56 51 47 LwA Surrounding 69 49 64 59 57 60 60 62 57
With LDR 60-30 With LDR 60-35
LwA Inlet 62 57 58 48 44 37 51 52 52 LwA Inlet 68 59 60 53 49 51 58 64 62

Measurement point: 0.36 m³/s @ 495 Pa Measurement point: 0.42 m³/s @ 591 Pa
Explosion Proof Fans | 241

proof fans
Explosion
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 51 58 60 61 63 63 67 62
LwA Outlet 77 52 59 65 71 69 68 71 66
LwA Surrounding 62 42 54 54 54 54 52 54 50
With LDR 70-40
LwA Inlet 63 51 51 49 47 49 53 59 56
Measurement point: 0.582 m³/s @ 361 Pa
242 | Explosion Proof Fans

DKEX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Suitable for use in battery-charging rooms, fume cupboards and
similar environments
• Integral thermistors (PTC*)
U-EK 230E
• Speed-controllable EX p. 374

DKEX fans can be installed in any position, and their compact design
makes them easy to install.
These fans have impellers with forward-curved blades and external
rotor motors. The casing is manufactured from galvanised
sheet steel with a copper inlet cone. R-DK4 KT
To protect the motor from overheating, PTC protective circuits in p. 360
the motors must be connected to a PTC triggering device certified
according to Directive 94/9/EC that isolates the motor from volt-
age supply immediately when activated. We recommend to use U-
EK230E for motor protection.
Explosion proof versions comply with EN 60079-0:2009, EN
proof fans
Explosion

14986:2007 and EN 60079-7:2007. Improved safety in accordance RTRD p. 357


with Ex e IIB+H2 T3 Gb.

* Positive Temperature Coefficient


Quick selection

RTRDU
p. 357
3734, 3733, 3731, 4231, 4232

1 DKEX 225-4
2 DKEX 250-4
3 DKEX 280-4
4 DKEX 315-4
5 DKEX 355-6
Ex e p. 380

REV p. 380

4 5 Min. static pressure as per dotted line.


1 2 3
Min. airflow 0.055 m³/s.

REV ATEX
p. 381
Technical data
DKEX 225-4 250-4 280-4 315-4 355-6
Art. no. 19962 19964 19966 19967 19968
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 490 900 1300 2100 1800
Current A 0.85 1.8 2.2 3.9 3.7
Max. air flow m3/s 0.41 0.659 0.777 1.04 1.39
R.p.m. min-1 1305 1355 1330 1380 840
Min. static back pressure Pa 90 145 280 250 -
Temperature range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Sound pressure level at 3 m dB(A) 53.7 58.9 60.8 63.9 58.3
Weight kg 13 17 24 35.5 40
Insulation class, motor F F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Motor protection U-EK230E EX U-EK230E EX U-EK230E EX U-EK230E EX U-EK230E EX
Certificate SP 12ATEX3165X
Explosion proof classification acc. to ATEX II 2G Ex e IIB+H2 T3 Gb
Speed control, five step Transformer RTRD 2* RTRD 4* RTRD 4* RTRD 7* RTRD 4*
Speed control, five step high/low Transformer RTRDU 2* RTRDU 4* RTRDU 4* RTRDU 7* RTRDU 4*
Wiring diagram p. 442-461 11a 11a 11a 11a 11a
* + U-EK230E EX
Explosion Proof Fans | 243

Dimensions Ventilation
accessories

USE p. 434
D
C
E

ISE p. 434
øL
A B
G

proof fans
Explosion
F

DKEX A B C D E F G
225-4 280 133 145 196 196 367 445
250-4 315 154 165 216 243 410 492
280-4 357 169 180 230 248 453 547
315-5 400 188 203 254 276 515 615
355-6 450 213 227 278 320 574 689
244 | Explosion Proof Fans

Performance
proof fans
Explosion

Min. static pressure 90 Pa Min. static pressure 145 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 46 55 63 60 65 65 62 57 LwA Inlet 77 50 62 67 66 72 71 69 65
LwA Outlet 76 45 51 64 68 72 68 67 64 LwA Outlet 77 48 53 65 68 72 70 69 64
LwA Surrounding 61 35 44 54 53 56 54 48 44 LwA Surrounding 66 41 43 58 55 62 59 56 48
Measurement point: 0.266 m³/s @ 291 Pa Measurement point: 0.461 m³/s @ 337 Pa

DKEX 280-4

Min. static pressure 280 Pa Min. static pressure 250 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 51 63 66 65 72 71 68 64 LwA Inlet 80 52 69 67 68 72 73 75 71
LwA Outlet 79 49 57 67 71 73 72 71 66 LwA Outlet 83 51 65 71 76 75 74 78 72
LwA Surrounding 68 48 52 59 55 63 62 58 57 LwA Surrounding 71 48 52 58 59 65 64 66 60
Measurement point: 0.411 m³/s @ 500 Pa Measurement point: 0.509 m³/s @ 595 Pa
Explosion Proof Fans | 245

proof fans
Explosion
dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k
LwA Inlet 76 49 62 62 67 68 68 71 66
LwA Outlet 78 47 60 65 71 70 69 74 68
LwA Surrounding 65 37 47 53 59 59 58 59 51
Measurement point: 0.641 m³/s @ 358 Pa
246 | Explosion Proof Fans

DVEX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Speed-controllable
• Integral thermistors (PTC*)
U-EK 230E EX
The DVEX models have impellers with backward-curved blades p. 374
and external rotor motors. The casing is made from aluminium
and the base frame from galvanised steel, with a copper inlet
cone.
To protect the motor from overheating these fans have integral
thermistors (PTC) with external leads which must be connected
R-DK4 KT
to the U-EK230E PTC triggering device.
p. 360
Sizes 315 - 450 come with pre-mounted tilting device (FTG), sup-
plied as accessory on sizes 560 and 630.
Explosions proof versions comply with EN 60079-0, 60079-7, EN
1127-1 and EN 13463-1. Improved safety in accordance with
Ex e IIB T3.
RTRD p. 357
proof fans

* Positive Temperature Coefficient


Explosion

Quick selection

RTRDU p. 357
4087, 4076, 4081, 3931

4063, 4089, 5584


1 DVEX 315D4 1 DVEX 560D6
2 DVEX 355D4 2 DVEX 630D6
3 DVEX 400D4
4 DVEX 450D4 Ex e p. 380

REV p. 380
1 2
1 2 3 4

REV ATEX
p. 381

Technical data
DVEX 315D4 355D4 400D4 450D4
Art. no. 32813 32814 32815 32816
Voltage/Frequency V/50 Hz 400 3~ 230/400 3~ 230/400 3~ 230/400 3~
Power W 120 260 390 720
Current A 0.23 0.81/0.47 0.76 1.42
Max. air flow m3/s 0.411 0.689 0.847 1.26
R.p.m. min-1 1340 1340 1350 1360
Temperature range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40
Sound pressure level at 4/10 m dB(A) 44.4/36.4 49/41 54/46 57/49
Weight kg 15.5 28 29 40
Insulation class, motor F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44
Motor protection U-EK230E U-EK230E U-EK230E U-EK230E
Certificate SP 07ATEX3129X SP 07ATEX3130X SP 07ATEX3131X SP 07ATEX3132X
Explosion proof classification acc. to ATEX II 2G Ex e IIB T4
Speed control, five step Transformer RTRD 2* RTRD 2* RTRD 2* RTRD 2*
Speed control, five step high/low Transformer RTRDU 2* RTRDU 2* RTRDU 2* RTRDU 2*
Wiring diagram p. 442-461 11a 11a/b 11a/b 11a/b
*) + U-EK230E EX. When using the RTRD or RTRDU together with an EX motor protection type U-EK230E EX, the two terminals in the transformer
marked “TK” must be bridged.
Explosion Proof Fans | 247

Dimensions Ventilation
F accessories
M 20

A
C

ASF p. 415

F
L
M

B
ASK p. 418

øI (4x)
E
øD K
ASS-EX
p. 434
DVEX £A B £C øD £E F øI £K £L M
315D4 560 382 470 192 330 146 12 406 304 330
355D4 720 442 618 226 450 199 12 566 466 390

proof fans
Explosion
400D4 720 442 618 255 450 199 12 566 466 390 FDS p. 420
450D4 900 517 730 289 535 237 12 636 490 465
560D6 1150 – 955 364 750 293 12 939 – 560
630D6 1150 – 955 410 750 293 12 939 – 560

FTG p. 415

SSD p. 419

TDA p. 415

VKS-EX
p. 427

DVEX 560D6 630D6


Art. no. 32818 32819
Voltage/Frequency V/50 Hz 230/400 3~ 230/400 3~
Power W 620 1070
Current A 1.23 2.15
Max. air flow m3/s 1.62 2.20
R.p.m. min-1 900 880
Temperature range, ambient and duct °C -20...+40 -20...+40
Sound pressure level at 3 m dB(A) 52/44 55/47
Weight kg 62 78
Insulation class, motor F F
Enclosure class, motor IP 44 IP 44
Motor protection U-EK230E U-EK230E
Certificate SP 07ATEX3134X SP 07ATEX3135X
Explosion proof II 2G Ex e IIB T4
Speed control, five step Transformer RTRD 2* RTRD 4*
Speed control, five step high/low Transformer RTRDU 2* RTRDU 4*
Wiring diagram p. 442-461 11a/b 11a/b
* + U-EK230E EX. When using the RTRD or RTRDU together with an EX motor protection type U-EK230E EX, the two terminals in the transformer
marked “TK” must be bridged.
248 | Explosion Proof Fans

Performance
proof fans
Explosion

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 64 48 53 56 60 55 53 49 37 LwA Inlet 68 50 58 61 63 60 58 52 43
LwA Outlet 67 48 53 56 63 63 59 52 40 LwA Outlet 72 51 58 64 67 67 63 55 48
Measurement point: 0.221 m³/s @ 162 Pa With TG 540-800
LwA Inlet 61 50 55 55 54 48 50 47 38
Measurement point: 0.417 m³/s @ 220 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA In let 72 58 62 66 67 64 62 55 47 LwA Inlet 76 58 64 71 71 68 66 58 52
LwA Outlet 77 57 62 69 72 72 67 59 50 LwA Outlet 80 58 67 74 75 75 70 62 53
With TG 640-800 With TG 640-800
LwA Inlet 67 57 60 62 60 55 56 51 43 LwA Inlet 71 57 62 67 64 59 60 54 48
Measurement point: 0.448 m³/s @ 275 Pa Measurement point: 0.699 m³/s @ 360 Pa
Explosion Proof Fans | 249

proof fans
Explosion
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 58 59 66 63 64 59 52 45 LwA Inlet 73 53 64 69 66 64 61 60 54
LwA Outlet 75 57 61 69 71 70 63 57 55 LwA Outlet 78 53 65 71 74 71 65 64 57
With TG 940-1230 With TG 940-1230
LwA Inlet 66 58 57 62 55 57 54 48 41 LwA Inlet 68 53 62 65 58 57 56 56 50
Measurement point: 0.962 m³/s @ 224 Pa Measurement point: 1.05 m³/s @ 318 Pa
250 | Explosion Proof Fans

DVV-EX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Speed-controllable via frequency converter

Roof fans DVV-Ex are designed to exhaust potentially explosive


atmospheres (mixtures of air and inflammables such as gases U-EK 230E EX
and steam) from explosion hazardous areas. The DVV-Ex fans p. 374
have impellers with backward-curved blades and IEC motor in
explosion protection “flameproof enclosure” - Ex d. The casing is
manufactured from seawater-resistant aluminium and the base
frame from galvanised steel, with a copper inlet cone. Suitable
for exhaust from zones 1 or 2, field of application II, for gases of
groups A and B and temperature classes T1 to T4. The fans are FRQ p. 361
classified to category 2G. Terminal box in explosion protection
“increased safety” - Ex e is mounted on casing. To protect motor
from overheating these fans have built-in thermistors (PTC) with
external leads (connection to U-EK230E PTC triggering device). On
request the fans can be factory fitted with sound attentuator on REV ATEX
the outlet side. p. 381
proof fans
Explosion

Single speed motors with 4 wires (3x power supply and PE)
and PTC led to connection box on casing - direct start enabled.

Quick selection

8413, 8300, 8412, 8308, 8200, 8201


8862,8863, 8864, 8417, 8865, 8448, 8867

1 DVV-EX 560D4 3 DVV-EX 630D4 1 DVV-EX 800D6


2 DVV-EX 560D6 4 DVV-EX 630D4-K 2 DVV-EX 800D6-K
5 DVV-EX 630D6 3 DVV-EX 800D8
6 DVV-EX 60D6-K 4 DVV-EX 800D8-K
5 DVV-EX 1000D6
6 DVV-EX 1000D8

1
4 3
3

5
4 1 6 5
2
6

Technical data
DVV-EX 560D4 560D6 630D4 630D4-K 630D6 630D6-K
Art. no. 30841 30844 30852 30847 30854 30850
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power at shaft (P2) W 1500 750 5500 3000 2200 1100
Current A 3.35 2.10 10.8 6.5 5.0 3.0
Starting current A 17.4 7.80 55.1 32.5 30.5 12.3
Max. air flow m3/s 2.64 1.81 5.36 3.5 3.36 2.28
Min. air flow m3/s 1.11 0.667 2.03 0.694 1.39 0.639
R.p.m. min-1 1415 915 1435 1415 960 915
Max. temp. of transported air °C 40 40 40 40 40 40
“ when speed controlled °C 40 40 40 40 40 40
Sound pressure level at 4/10 m dB(A) 69/61 60/52 75/69 71/63 64/58 61/53
Weight kg 72 69 161 120 133 107
Insulation class, motor F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIQ 06 ATEX 236X
Explosion proof classification acc. to ATEX II 2G c Ex d IIB T4
Wiring diagram p. 442-461 15d 15d 15d 15d 15d 15d
Explosion Proof Fans | 251

Dimensions Ventilation
accessories
A øH G

VKSV-EX
p. 427
øD
B

ASFV p. 429
C

E

F
ASSV-EX
p. 434
DVV-EX A B C øD £E £F G øH
560D4/D6 808 750 20 438 600 706 12XM8 14
630D4/D4-K/D6/D6-K 1100 958 40 541 880 990 12XM8 18

proof fans
Explosion
800D6/D6-K/D8/D8-K 1272 1175 40 674 880 990 16xM10 18
FDVE-EX
1000D6/D8 1500 1350 70 751 1040 1154 16xM10 18 p. 420

SSV-EX
p. 425

SSVE-EX
p. 422

ASK/F
p. 418

FDV-EX
p. 420

DVV-EX 800D6 800D6-K 800D8 800D8-K 1000D6 1000D8


Art. no. 30856 30859 30858 30861 30862 30863
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power at shaft (P2) W 5500 2200 2200 1100 11 000 5500
Current A 11.80 5.0 5.5 3.25 23.5 13.4
Starting current A 72 30.5 23.7 12.4 141 64.3
Max. air flow m3/s 7.08 5.0 5.28 3.92 12.4 9.44
Min. air flow m /s 3.06
3
1.44 2.28 1.11 0.556 0.556
R.p.m. min-1 955 960 710 695 965 715
Max. temp. of transported air °C 40 40 40 40 40 40
“ when speed controlled °C 40 40 40 40 40 40
Sound pressure level at 4/10 m dB(A) 72/66 66/60 66/57 59/53 73/66 66/58
Weight kg 205 171 189 157 370 348
Insulation class, motor F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIQ 06 ATEX 236X
Explosion proof II 2G c Ex d IIB T4
Wiring diagram p. 442-461 15d 15d 15d 15d 15d 15d
252 | Explosion Proof Fans

Performance

4-pole
4-pole

6-pole
6-pole

DVV-EX 560D4 DVV-EX 630D4


proof fans
Explosion

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 88 61 73 81 82 81 79 76 68 LwA Inlet 100 73 85 93 94 93 91 88 80
LwA Surrounding 90 63 75 83 84 83 81 78 70 LwA Surrounding 103 76 88 96 97 96 94 91 83
Measurement point: 2.1 m³/s @ 310 Pa Measurement point: 4.58 m³/s @ 370 Pa

DVV-EX 560D6 DVV-EX 630D6


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 81 58 67 73 77 72 70 68 56 LwA Inlet 90 67 76 82 86 81 79 77 65
LwA Surrounding 83 60 69 75 79 74 72 70 58 LwA Surrounding 92 69 78 84 88 83 81 79 67
Measurement point: 1.50 m³/s @ 125 Pa Measurement point: 2.3 m³/s @ 270 Pa

4-pole
6-pole

6-pole 8-pole

DVV-EX 630D4-K DVV-EX 800D6


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 92 65 77 85 86 85 83 80 72 LwA Inlet 93 70 79 85 89 84 82 80 68
LwA Surrounding 94 67 79 87 88 87 85 82 74 LwA Surrounding 95 72 81 87 91 86 84 82 70
Measurement point: 2.80 m³/s @ 400 Pa Measurement point: 6.10 m³/s @ 250 Pa

DVV-EX 630D6-K DVV-EX 800D8


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 58 69 71 78 73 72 68 55 LwA Inlet 82 64 70 73 77 74 74 69 58
LwA Surrounding 84 60 71 73 80 75 74 70 57 LwA Surrounding 84 66 72 75 79 76 76 71 60
Measurement point: 1.38 m³/s @ 350 Pa Measurement point: 2.50 m³/s @ 330 Pa
Explosion Proof Fans | 253

6-pole
6-pole

8-pole
8-pole

proof fans
Explosion
DVV-EX 800D6-K DVV-EX 1000D6
dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 84 60 71 73 80 75 74 70 57 LwA Inlet 92 69 78 84 88 83 81 79 67
LwA Surrounding 86 62 73 75 82 77 76 72 59 LwA Surrounding 94 71 80 86 90 85 83 81 69
Measurement point: 4.00 m³/s @ 280 Pa Measurement point: 6.94 m³/s @ 650 Pa

DVV-EX 800D8-K DVV-EX 1000D8

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]

63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

LwA Inlet 75 58 64 66 70 68 68 60 49 LwA Inlet 84 66 72 75 79 76 76 71 60

LwA Surrounding 77 60 66 68 72 70 70 62 51 LwA Surrounding 86 68 74 77 81 78 78 73 62

Measurement point: 3.10 m³/s @ 150 Pa Measurement point: 6.11 m³/s @ 310 Pa
254 | Explosion Proof Fans

AW-EX Electrical
accessories
• Certified according to ATEX directive 94/9/EC
• Speed-controllable
• Integral thermal contact

The AW-EX fans have speed controllable external rotor motors. U-EK 230E EX
The fans have a square plate for wall mounting and are painted p. 374
in standard black. The casing and impeller is manufactured from
sheet steel. To protect the motor from overheating, integral ther-
mistors are fitted with external leads which must be connected
to the U-EK230E triggering device.
The AW-Ex fan motor is approved according to ATEX. Useful for
Zone 1 and 2, groups IIA and IIB and temperature class T1, T2, T3 RTRD p. 357
or T4 (only 355 and 420). Ignition protection Ex e.

RTRDU p. 357
proof fans
Explosion

Quick selection

Ex e p. 380
5398, 5401, 5408, 5409

1 AW 355D4-2-EX
2 AW 420D4-2-EX
3 AW 550D6-2-EX
4 AW 650D6-2-EX

REV p. 380

REV ATEX
1 2 3 4
p. 381

Technical data
AW 355 D4-2-EX 420 D4-2-EX 550 D6-2-EX 650 D6-2-EX
Art. no. 5969 5970 5971 5972
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~
Power W 286 536 579 1077
Current A 0.493 0.943 1.15 1.78
Max. air flow m3/s 0.72 1.3 1.84 3.04
R.p.m. min-1 1341 1269 697 790
Max. temp. of transported air °C 40 40 40 40
“ when speed controlled °C 40 40 40 40
Sound pressure level at 3 m dB(A) 62 69 67.2 72
Weight kg 9 10 13 20
Insulation class, motor F F F F
Enclosure class, motor IP 44 IP 44 IP 44 IP 44
Motor protection U-EK230E EX U-EK230E EX U-EK230E EX U-EK230E EX
Certificate ZELM 05ATEX0279X
Explosion proof classification acc. to ATEX II 2G c Ex e IIB T4
Speed control, five step Transformer RTRD 2* RTRD 2* RTRD 2* RTRD 2*
Speed control, five step high/low Transformer RTRDU 2* RTRDU 2* RTRDU 2* RTRDU 2*
Wiring diagram p. 442-461 19 19 19 19
* + U-EK230E EX
Explosion Proof Fans | 255

Dimensions

A
B
C
D
1,5

J
øE

øF

proof fans
Explosion
øH

I
G

AW A B C D øE øF G øH £I £J
355 D4-2-EX 138 48 70 16 350.5 356 125 12 385 423
420 D4-2-EX 138 71 70 16 419 426 125 14.5 460 503
550 D6-2-EX 138 72 55 18 551 558 143 14.5 610 650
650 D6-2-EX 162 66 78 18 651 658 161 14.5 730 770
256 | Explosion Proof Fans

Performance
proof fans
Explosion

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet/Outlet 69 38 52 64 60 64 62 56 49 LwA Inlet/Outlet 75 47 61 67 70 70 68 62 54
Measurement point: 0.5 m³/s @ 80 Pa Measurement point: 0.85 m³/s @ 110 Pa

1 2 3 4

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet/Outlet 72 40 60 61 66 68 66 58 49 LwA Inlet/Outlet 76 46 58 67 70 71 70 63 55
Measurement point: 1.29 m³/s @ 63 Pa Measurement point: 2.3 m³/s @ 80 Pa
Explosion Proof Fans | 257
Reference: Choren Industries, Freiberg (Sachsen), Germany

Type of Building: Choren is an internationally leading supplier of technologies


for the production of synthesis gas from carbonaceous solids.
Products/Solution: Explosion proof roof fans, type DVV-EX
Explosion proof axial fans, type AW-EX

proof fans
Explosion
258 | Explosion Proof Fans

AXC-EX Electrical
accessories
• Aluminium die cast aerofoil impeller with adjustable pitch angle
• Casing, hot dip galvanized steel, to EN ISO 1641
• Aluminium anti-spark ring
• Three phase motors, IP55, insulation class F, in accordance with U-EK 230E EX
EN 60034, IEC 85. Supplied with terminal box Ex e mounted at p. 374
the outer side of the casing

The AXC-EX range of long cased medium pressure axial fans is


available in sizes 315 up to 900 mm (up to size 1600 on request)
impeller diameter. The possibility to set the pitch angles at the
FRQ p. 361
factory offers a wide performance and maximum flexibility to
match precisely individual airflow requirements.
The stock range offers a standard selection with maximum air-
flow for the installed motor power. The fans can be used for
zones 1 or 2, field of application II, for gases of groups IIA, IIB,
and IIC and temperature classes T1 to T4. The fans are classified REV ATEX
to category 2G. The fans are certified under Sira 07ATEX6341X. p. 381
proof fans
Explosion

The Ex d motors are equipped with PTC thermistors for optimum


motor protection. The motor is speed controllable by frequency
converter.

Technical data
AXC-EX 355-7 355-7 400-7 400-7 450-7 450-7 450-7 450-7 450-7 500-9
12°-4 32°-4 14°-4 32°-4 17°-2 24°-2 28°-2 14°-4 32°-4 22°-4
Art. no. 35758 33007 35759 33008 35760 33001 35761 35762 33009 33010
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Max. power load kW 0.37 0.37 0.37 0.37 1.5 2.2 3.0 0.55 0.55 0.55
Power (P1) W 177 225 234 337 1400 2532 2757 225 473 546
Starting current A 3.9 3.9 3.9 3.9 19.8 26.2 35.1 6.8 6.8 6.8
Current A 0.797 0.837 0.8 0.845 2.44 4.81 5.52 0.894 1.16 1.21
Max. air flow m3/s 0.38 0.92 0.654 1.28 2.12 2.81 3.16 0.917 1.8 1.75
R.p.m. min-1 1488 1471 1476 1461 2911 2924 2934 1481 1441 1428
Temp. range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Weight kg 30 40 34 75 62 63 77 62 55 65
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Explosion proof classification II 2G c Ex d IIC T4
acc. to ATEX
Certificate SIRA 07ATEX6341X
Wiring diagram p. 442-461 44a 44a 44a 44a 44a 44a 44a 44a 44a 44a

AXC-EX 500-9 500-9 500-9 500-9 560-9 560-9 560-9 560-9 560-9 630-9
16°-2 26°-2 28°-4 36°-2 18°-2 20°-4 24°-2 26°-4 30°-2 16°-2
Art. no. 33002 33003 33011 35763 33004 33012 33005 33013 35764 33006
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Max. power load kW 3.0 5.5 0.75 7.5 5.5 0.75 7.5 1.1 11 7.5
Power (P1) W 3396 4753 662 7323 5502 779 6977 1088 7441 7862
Starting current A 35.1 64.8 8.4 96 64.8 8.4 96 11.6 140 96
Current A 5.61 7.87 1.55 11.8 8.76 1.68 11.5 2.04 14.8 12.6
Max. air flow m3/s 2.78 4.03 2.23 5.17 4.52 2.46 5.43 3.18 6.63 6.18
R.p.m. min-1 2905 2945 1439 2934 2932 1428 2944 1434 2972 2936
Temp. range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Weight kg 82 130 65 135 155 90 155 93 167 155
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIRA 07ATEX6341X
Explosion proof classification II 2G c Ex d IIC T4
acc. to ATEX
Wiring diagram p. 442-461 44a 44b 44a 44b 44b 44a 44b 44a 44b 44b
Explosion Proof Fans | 259

Dimensions Ventilation
accessories
W

A ½W

øH ESD-F p. 438

GFL-AR/AXC
øD
øC
øB

p. 437

EV-EX/AXC
øE p. 435
F

AXC-EX A øB øC øD øE F øH I

proof fans
Explosion
355 375 435 355 343 395 500 10 8x45° FSD p. 433
400 450 480 400 387 450 550 12 8x45°
450 500 530 450 436 500 605 12 8x45°
500 540 590 500 486 560 659 12 12 x 30°
560 750 650 560 546 620 730 12 12 x 30°
MFA-AR/AXC
p. 432
630 500 720 630 614 690 800 12 12 x 30°
710 500 800 710 693 770 880 12 12 x 22.5°
800 500 890 800 783 860 975 12 16 x 22.5°
900 640 1005 900 875 970 1075 15 16 x 22.5°
SG AR/AXC
p. 431

Cable gland set


p. 435

AXC-EX 630-9 630-9 630-9 710-9 710-9 800-9 800-9 900-10 900-10 900-10
18°-4 20°-2 30°-4 26°-4 30°-4 18°-4 28°-4 18°-4 26°-4 30°-4
Art. no. 33014 35765 33015 35766 33016 33017 33018 33019 33020 35767
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Max. power load kW 1.1 11 3.0 2.2 4.0 4.0 7.5 7.5 11 15
Power (P1) W 1156 9132 2181 3101 3360 2716 5339 6212 11 964 12052
Starting current A 11.6 140 32.6 23.4 51.5 51.5 92 92 143 223
Current A 2.15 17.4 4.69 5.31 6.03 5.27 11.8 12.5 16.7 22.4
Max. air flow m3/s 3.44 7.13 5.14 6.26 6.7 6.57 9.1 10 12.4 14.5
R.p.m. min-1 1429 2970 1465 1398 1457 1467 1480 1476 1479 1478
Max. temp. of transported air °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Weight kg 95 169 105 106 130 130 158 255 330 316
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIRA 07ATEX6341X
Explosion proof II 2G c Ex d IIC T4
Wiring diagram p. 442-461 44a 44b 44a 44a 44a 44a 44b 44b 44b 44b
260 | Explosion Proof Fans

Quick selection

8106, 8040, 7858, 7977, 7984

7987, 7978, 7985, 8004, 7986


1 AXC-EX 355-7/12°-4 7 AXC-EX 450-7/32°-4 1 AXC-EX 450-7/14°-4
2 AXC-EX 450-7/28°-2
2 AXC-EX 355-7/32°-4 8 AXC-EX 500-9/16°-2 3 AXC-EX 500-9/22°-4
3 AXC-EX 400-7/14°-4 4 AXC-EX 500-9/26°-2
5 AXC-EX 500-9/28°-4
4 AXC-EX 400-7/32°-4 6 AXC-EX 560-9/18°-2
5 AXC-EX 450-7/17°-2 8 7 AXC-EX 560-9/20°-4
6 AXC-EX 450-7/24°-2 6

3 5 7 2 4 6

3 2 4 7 1
1
proof fans
Explosion

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
LwA Inlet/Outlet 63 125 250 500 1k 2k 4k 8k LwA Inlet/Outlet 63 125 250 500 1k 2k 4k 8k
AXC-EX AXC-EX
355-7/12°-4 71 43 53 61 66 66 63 59 52 450-7/14°-4 78 50 60 69 73 74 71 67 59
355-7/32°-4 74 69 68 69 68 67 64 59 53 450-7/28°-2 99 71 81 89 94 94 91 87 80
400-7/14°-4 76 48 58 66 71 71 68 64 57 500-9/22°-4 86 81 80 81 80 79 76 71 65
400-7/32°-4 76 48 58 66 71 71 68 64 57 500-9/26°-2 102 97 92 95 97 95 94 90 84
450-7/17°-2 95 67 77 85 90 90 87 83 76 500-9/28°-4 87 82 81 82 81 80 77 72 66
450-7/24°-2 96 91 86 89 91 88 88 84 78 560-9/18°-2 106 101 96 99 101 99 98 94 88
450-7/32°-4 82 77 76 77 76 75 72 67 61 560-9/20°-4 91 86 85 86 85 84 81 76 70
500-9/16°-2 100 95 90 93 95 93 92 88 82

700
7994, 7997, 8003, 8005, 8006

8009, 8030, 8035, 8032, 8020


1 AXC-EX 500-9/36°-2 5 AXC-EX 630-9/16°-2 1 AXC-EX 630-9/20°-2 5 AXC-EX 800-9/28°-4
2 AXC-EX 560-9/24°-2 6 AXC-EX 630-9/18°-4 2 AXC-EX 710-9/26°-4 6 AXC-EX 900-10/18°-4
3 AXC-EX 710-9/30°-4 7 AXC-EX 900-10/26°-4
3 AXC-EX 560-9/26°-4 7 AXC-EX 630-9/30°-4
4 AXC-EX 800-9/18°-4 8 AXC-EX 900-10/30°-4
4 AXC-EX 560-9/30°-2

1 2
1
4

2 3 4 8
3 5 6 7

5 6 7

16

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
LwA Inlet/Outlet 63 125 250 500 1k 2k 4k 8k LwA Inlet/Outlet 63 125 250 500 1k 2k 4k 8k
AXC-EX AXC-EX
500-9/36°-2 105 77 86 96 100 100 97 93 86 630-9/20°-2 107 79 89 97 102 102 99 95 88
560-9/24°-2 108 103 98 101 103 101 100 96 90 710-9/26°-4 95 67 77 85 90 90 87 83 76
560-9/26°-4 93 88 87 88 87 86 83 78 72 710-9/30°-4 93 88 87 88 87 86 83 78 72
560-9/30°-2 108 79 90 98 102 103 100 96 89 800-9/18°-4 97 92 91 92 91 90 87 82 76
630-9/16°-2 111 106 101 104 106 104 103 99 93 800-9/28°-4 100 95 94 95 94 93 90 85 79
630-9/18°-4 96 91 90 91 90 89 86 81 75 900-10/18°-4 101 91 89 95 96 94 91 86 80
630-9/30°-4 99 94 93 94 93 92 89 84 78 900-10/26°-4 104 94 97 99 97 96 92 86 80
900-10/30°-4 106 78 88 96 101 101 98 94 87
Explosion Proof Fans | 261

Reference: Bolshoi Ice Palace, Sochi, Russia

Type of Building: The building has been constructed for the Olympic Games in 2014. It is located in the Olympic Park
near the sea. It will be a major hockey stadium during the Games in 2014. The Arena is designed for 12,000 visitors.
The architecture of the Arena resembles the famous Fabergé egg, based on the concept of the image of frozen droplets.
Products/Solution: The arena is equipped with 75 AXC fans for smoke pressurization. TA units and duct fans are
used for supply and extract air.
Completion date of construction was 2012. Total building area is around 55,000 m2.

proof fans
Explosion
262 | Explosion Proof Fans

AXCBF-EX Electrical
accessories
• Aluminium die cast aerofoil impeller with adjustable pitch angle
• Casing, hot dip galvanized steel, to EN ISO 1641
• Aluminium anti-spark ring
• Three phase motors, IP55, insulation class F, in accordance with U-EK 230E EX
EN 60034, IEC 85. p. 374

The Systemair AXCBF-EX range of bifurcated medium pressure axial


fans has been developed for applications with an explosive atmo-
sphere which would either require special motors or reduce the life-
time of a standard motor. The Ex(d) motors of AXCBF-EX are out of FRQ p. 361
the airstream.
Available in sizes from 250 up to 800 mm impeller diameter. The
stock range offers a standard selection with maximum airflow for
the installed motor power. The fans are suitable for zones 1 or 2,
Ex e p. 380
field of application II, for gases of groups IIA, IIB and IIC and for tem-
perature classes T1 to T4. The fans are classified to category 2G.
The fans are certified under the no Sira 07ATEX6341X.
proof fans
Explosion

The Ex d motors are equipped with PTC thermistors for optimum


motor protection. The motor is speed controllable by frequency
converter. REV ATEX
AXCBF-EX bifurcated axial fan casings are heavy gauge, hot dip p. 381
galvanized, with spun flanges for high rigidity. The motor compart-
ment allows easy access to the motor terminal box for wiring. Three
phase B3 foot mounted motors, totally enclosed and fan cooled.

Quick selection
8929, 7831, 7832, 7827, 7833

7826, 8041, 7834, 7846, 8039


1 AXCBF-EX 250-6/28°-2
1 AXCBF-EX 400-7/32°-4
2 AXCBF-EX 250-6/28°-4
2 AXCBF-EX 500-9/18°-2
3 AXCBF-EX 315-7/30°-2
3 AXCBF-EX 500-9/30°-4
4 AXCBF-EX 315-7/32°-4
4 AXCBF-EX 630-9/26°-4
5 AXCBF-EX 400-7/22°-2
5 AXCBF-EX 800-9/18°-4

1 3 4 2 5
1 3 5
4
2

Technical data
AXCBF-EX 250-6/28°-2 250-6/28°-4 315-7/30°-2 315-7/32°-4 400-7/22°-2
Art. no. 33021 33025 33022 33026 33023
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Max. power load kW 0.37 0.25 0.75 0.25 2.20
Power (P1) W 309 93.4 693 155 1911
Starting current A 4.5 2.9 8.4 2.9 26.2
Current A 0.79 0.563 1.43 0.609 3.16
Max. air flow m3/s 0.463 0.225 0.911 0.459 1.71
R.p.m. min-1 2916 1487 2885 1476 2918
Temp. range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Weight kg 30 30 72 65 64
Insulation class, motor F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIRA 07ATEX6341X
Explosion proof classification acc. to ATEXJ II 2G c Ex d IIC T4
Wiring diagram p. 442-461 44a 44a 44a 44a 44a
Explosion Proof Fans | 263

Dimensions Ventilation
accessories
A
J
I
øH
FSD p. 433
øC
øD
øB

øE

MFA-AXCBF
p. 432

øF
EV-EX/AXC
p. 435
AXCBF-EX A øB øC øD øE øF øH I J
250 535 448 328 250 238 280 10 4 x 90° 45
315 535 452 385 320 308 355 10 8 x 45° 22.5

proof fans
Explosion
400 625 585 480 401 388 450 10 8 x 45° 22.5
GFL-AR/AXC
500 short version 660 695 590 504 490 560 12 12 x 30° 15 p. 437
500 long version 710 695 590 504 490 560 12 12 x 30° 15

A J
I

øH
øC
øD
øB

øE

AXCBF-EX A øB øC øD øE øH I J
630 790 728 634 618 690 12 12 x 30° 15
800 880 890 797 778 860 12 16 x 22.5° 11.25

AXCBF/EX 400-7/32°-4 500-9/18°-2 500-9/30°-4 630-9/26°-4 800-9/18°-4


Art. no. 33027 33024 33028 33029 33030
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Max. power load kW 0.55 2.2 1.1 2.2 4.0
Power (P1) W 444 3054 863 2187 3403
Starting current A 6.8 26.2 11.6 23.4 51.6
Current A 1.1 4.78 1.85 4.27 6.02
Max. air flow m3/s 1.08 2.71 1.85 3.4 5.88
R.p.m. min-1 1444 2840 1450 1459 1457
Temp. range, ambient and duct °C -20...+40 -20...+40 -20...+40 -20...+40 -20...+40
Weight kg 58 85 77 112 185
Insulation class, motor F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Certificate SIRA 07ATEX6341X
Explosion proof II 2G c Ex d IIC T4
Wiring diagram p. 442-461 44a 44a 44a 44a 44a
264 | Smoke Extract Fans

Smoke Extract Fans


IE2
2009/640/EG
120°C 200°C 300°C 120min 400°C 120min 600°C 120min

Solutions for your safety


extract fans
Smoke

General Systemair range


Fire develops smoke and heat. Within Mechanical smoke and heat extract Systemair offers different types of smoke
buildings these two factors represent systems are particularly important for: and heat extract fans: Centrifugal roof fans,
a substantial danger for human beings, • High rooms without windows centrifugal wall/duct fans and axial fans.
animals and the inventory. Constantly rising • Underground floors and rooms All fans are approved for dual purpose
temperatures might lead to a so-called • Buildings with a constantly high wind ventilation, i.e. for normal daily ventilation
“flash-over”, where the fire spreads like an load and for emergency ventilation in case of
explosion. • Large rooms with a high fire load a fire. DVV roof fans are also available
Buildings must be designed in a way that • Rooms with sprinkler systems, working as DVV/120 fans for continuous exhaust
spreading of smoke and heat in case of a against the thermal lift. of air up to 120°C. Tailormade accessory
fire can be kept as small as possible. Escape systems complete the range.
routes have to be kept free of smoke to
a largest possible extent, and fire fighting
routes for the fire services have to be
created.
Contrary to natural smoke outlets (i.e.
roof openings), mechanical smoke and heat
extract systems immediately provide full
capacity.
Smoke Extract Fans | 265

Safety-relevant applications require Typical applications: Certified in accordance with EN


customised solutions without compro- • In mechanical smoke and heat 12101-3
mise. As one of the leading suppliers in extract systems installed in Systemair smoke and heat extract fans
the field of ventilation technology, Sys- shopping centres, airports, have been certified in accordance with
temair offers an unprecedented large industrial buildings, big cinemas EN 12101-3. CE certification in accord-
range of smoke extract fans. They set and theatres, warehouses etc. ance with EN 12101-3, 2002-06 by
global standards. For this reason, you • For industrial process air with the TUV Süd, Munich, LGAI, Barcelona
have the right to expect significantly

extract fans
Smoke
increased temperatures or by BSi, UK. Systemair is
more from us in the important area of • Car park and tunnel ventilation ISO 9001 approved. The
smoke extraction. Systemair quality is regu-
larly monitored by TÜV Süd.
Applications
Systemair smoke and heat extract
fans covers the following temperature
classes
F300 – 300°C/120 min.
F400 – 400°C/120 min.
F600 – 600°C/120 min.

KBR/F IE2
266 DVG/F IE2
284 AJR TR IE2
310
2009/640/EG 2009/640/EG 2009/640/EG
200°C 400°C 120min 120°C 400°C 120min

Smoke extract roof fan Jet fan for car parks


Smoke extract fan

NEW!
DVV/F IE2
272 KVB/F 292 AJ8 IE2
312
2009/640/EG 2009/640/EG
120°C 400°C 120min 600°C 120min 400°C 120min

Smoke extract roof fan Jet fan for car parks


Smoke extract box fan

NEW!
DVV/F XS, XL 278 MUB/F 296 IV (B) 314
IE2
2009/640/EG
400°C 120min 300°C 120min 400°C 120min

120°C

Induction fan
400°C 120min

Smoke extract roof fan Smoke extract fan

NEW!
DVG EC 280 AXC(B), AXC(F) 302 WVA/WVI 318
300°C 120min 400°C 120min 400°C 120min 600°C 120min

120°C

Smoke extract axial fan


400°C 120min

Smoke extract roof fan Smoke extract fan


266 | Smoke Extract Fans

KBR/F Electrical
accessories
• Integral cold conductor (PTC) or integral thermal contacts
• Speed-controllable
• Max. temperature of transported air 200°C continuously
• 400°/120 min. (F400) REV p. 380
• Insulated casing
• Low sound level
• Tested acc. to EN 12101-3
RTRD p. 357
The KBR/F fans smoke extract unit are used in case of fire to ex-
tract smoke gases from rooms, and also during normal working
conditions for standard temperature up to 200°C.
IE2
2009/640/EG
The KBR/F units have backward curved impellers made of gal-
vanized steel except size 355 which has a steel impeller painted RTRDU p. 357
200°C 400°C 120min
RAL 9005. The units have a swing out door for easy inspec-
tion and service. The direction of the door opening can easily be
changed from left to right at site. The double skin casing is insu-
lated with 50 mm rockwool.
In normal operation, to protect the motors from overheat- S-DT2 p. 381
ing the KBR/F fans have integral thermal contacts with exter-
nal leads for connection to a TK triggering device. Sizes 280D2,
280D2-4, 315D2 IE2, 355D2/K IE2 and 355D1 IE2 have integral
cold conductors (PTC). In case of fire all protective devices must
extract fans

be bridged to guarantee functionality. STDT/S-ET


p. 373
Smoke

AES p. 383

FRQ p. 361

U-EK230E
p. 374

Technical data
KBR/F 280D2 280D2-4 280DV 315DV 315D2 IE2 355E4
Art. no. 31586 31588 31587 31590 34509 31554
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 230 1~
Connection Y Y/YY D/Y D/Y Y -
Power (P1) W 730 783/99 209 244 1218 438
Current A 1.24 1.2/0.33 1.39 1.39 2.33 2.1
Starting Current A 11.4 - 4.6 4.6 22.4 4.9
Max. air flow m3/s 0.824 0.806/0.422 0.422 0.611 1.09 0.972
R.p.m. min-1 2820 2800/1410 1360 1360 2928 1330
Max. temp. of transported air °C 200 200 200 200 200 200
Max. temp. of transported air for 120 min. °C 400 400 400 400 400 400
Sound pressure level at 4 m dB(A) 44 44/33 33 36 50 44
Sound pressure level at 10 m dB(A) 36 36/25 25 28 42 33
Weight kg 53 58/49 54 62.5 72 81
Insulation class, motor F F F F F F
Enclosure class, motor IP 55 IP 55 IP 54 IP 54 IP 54 IP 54
Wiring diagram p. 442-461 17a 14b 17c 17c 17a 21
Smoke Extract Fans | 267

Dimensions Ventilation
J accessories
A I 38
K

F
E

EVH p. 436

øG
B
C øG

H
LRK(F) p. 430

35
D 50

50
E L

WBK p. 414
KBR/F A B C D E F øG H I J L K
280 171.5 537 295 360 625 60 280 234 - 291 620 8
315DV 187.5 600 339 398 690 60 315 249 153.5 307 800 8
315D2 187.5 600 339 398 690 130 315 249 153.5 307 800 78
355 206.5 655 372 451 770 60 355 273 – 331 770 8 WSD-KBT
355D2 206.7 655 372 451 770 130 355 273 - 331 770 78 p. 414

Quick selection

extract fans
Smoke
UGF p. 414

1 KBR/F 355E4
1 KBR/F 280D2
2 KBR/F 280D2-4
2 KBR/F 355E4/K
3 KBR/F 280DV
3 KBR/F 355DV
4 KBR/F 315DV 4 KBR/F 355DV/K
5 KBR/F 315D2 IE2 5 KBR/F 355K D2 IE2
6 KBR/F 355D2 IE2

2 3 4 1 5 2 4 1 3 5 6

KBR/F 355E4/K 355DV 355DV/K 355K D2 IE2 355D2 IE2


Art. no. 32891 31594 31592 34511 34510
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 400 3~ 400 3~ 400 3~
Connection - D/Y D/Y Y D
Power (P1) W 319 550 323 2141 3641
Current A 2.1 1.88 1.88 3.85 5.95
Starting Current A 4.9 6.4 6.4 30.9 46.8
Max. air flow m3/s 0.778 1.06 0.806 1.63 2
R.p.m. min-1 1330 1360 1360 2909 2889
Max. temp. of transported air °C 200 200 200 200 200
Max. temp. of transported air for 120 min. °C 400 400 400 400 400
Sound pressure level at 4 m dB(A) 42 41 41 53 53
Sound pressure level at 10 m dB(A) 31 33 33 45 45
Weight kg 81 83 83 95 102
Insulation class, motor F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 55 IP 54
Wiring diagram p. 442-461 21 17c 17c 17a 17b
268 | Smoke Extract Fans

Performance
Q [m3/h] Q [m3/h]
0 500 1000 1500 2000 2500 3000 3500 0 400 800 1200 1600 2000
1400 350

1200 KBR/F 280D2-4 300


KBR/F 280DV

1000 250
86
74
Ps [Pa]

Ps [Pa]
800 200
2-pole
600 150

400 100
74

4-pole 72
200 50
72
84

0 0
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 0 0,1 0,2 0,3 0,4 0,5 0,6
Q [m3/s] Q [m3/s]
0 0

200 200

P [W]
P [W]

400 400

600 600

800 800

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
extract fans

2-pole LwA Inlet 74 71 68 66 62 59 57 53 49


LwA Inlet 86 - 80 78 74 71 69 65 61 LwA Outlet 76 73 70 68 64 61 59 55 51
Smoke

LwA Outlet 88 - 82 80 76 73 71 67 61 LwA Surrounding 56 53 50 48 44 41 39 35 31


LwA Surrounding 67 - 61 59 55 52 50 46 42 Measurement point: 0.2 m³/s @ 220 Pa
Measurement point: 0.42 m³/s @ 800 Pa
4-pole
LwA Inlet 74 - 68 66 62 59 57 53 49
LwA Outlet 76 - 70 68 64 61 59 55 51
LwA Surrounding 56 - 50 48 44 41 39 35 31
Measurement point: 0.22 m³/s @ 220 Pa

Q [m3/h]
0 400 800 1200 1600 2000 2400
450

400 KBR/F 315DV KBR/F 315D2 IE2

350

300
Ps [Pa]

250

200

150

100

50

0
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7
Q [m3/s]

0
100
P [W]

200

300

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 – 75 74 69 67 63 57 54 LwA Inlet 91 - 89 88 83 81 77 71 68
LwA Outlet 79 – 77 76 71 68 65 59 56 LwA Outlet 93 - 91 90 85 83 79 73 70
LwA Surrounding 59 – 57 56 51 49 45 39 36 LwA Surrounding 73 - 71 70 65 63 59 53 50
Measurement point: 0.38 m³/s @ 250 Pa Measurement point: 0.46 m³/s @ 1276 Pa
Smoke Extract Fans | 269

Q [m3/h] Q [m3/h]
0 500 1000 1500 2000 2500 3000 3500 0 400 800 1200 1600 2000 2400 2800
700 500

450 KBR/F 355E4/K


600 KBR/F 355E4
400
500 350

300

Ps [Pa]
Ps [Pa]

400
250
300
200

200 150

100
100
50

0 0
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8
Q [m3/s] Q [m3/s]
0 0
100 100

P [W]
P [W]

200 200
300 300
400 400

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

extract fans
Smoke
LwA Inlet 82 – 80 79 74 72 68 62 59 LwA Inlet 82 - 80 79 74 72 68 62 59
LwA Outlet 84 – 82 81 76 74 70 64 61 LwA Outlet 84 – 82 81 76 74 70 64 61
LwA Surrounding 64 – 62 61 56 54 50 44 41 LwA Surrounding 64 – 62 61 56 54 50 44 41
Measurement point: 0.42 m³/s @ 465 Pa Measurement point: 0.42 m³/s @ 320 Pa

Q [m3/h] Q [m3/h]
0 1000 2000 3000 4000 0 400 800 1200 1600 2000 2400 2800 3200
700 600

600 KBR/F 355DV KBR/F 355DV/K


500

500
400
Ps [Pa]

Ps [Pa]

400
300
300
200
200

100
100

0 0
0 0,2 0,4 0,6 0,8 1,0 1,2 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9
Q [m3/s] Q [m3/s]
0
0
200 100
P [W]

P [W]

200
400
300
600 400

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 – 80 79 74 72 68 62 59 LwA Inlet 82 – 80 79 74 72 68 62 59
LwA Outlet 84 – 82 81 76 74 70 64 61 LwA Outlet 84 – 82 81 76 74 70 64 61
LwA Surrounding 64 – 62 61 56 54 50 44 41 LwA Surrounding 64 – 62 61 56 54 50 44 41
Measurement point: 0.69 m³/s @ 320 Pa Measurement point: 0.32 m³/s @ 398 Pa
270 | Smoke Extract Fans

KBR/F 355K D2 IE2 KBR/F 355D2 IE2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
extract fans

LwA Inlet 94 - 92 91 86 84 80 74 71 LwA Inlet 94 - 92 91 86 84 80 74 71


LwA Outlet 96 - 94 93 88 86 82 76 73 LwA Outlet 96 - 94 93 88 86 82 76 73
Smoke

LwA Surrounding 76 - 74 73 68 66 62 56 53 LwA Surrounding 76 - 74 73 68 66 62 56 53


Measurement point: 0.72 m³/s @ 1431 Pa Measurement point: 0.83 m³/s @ 1800 Pa
Smoke Extract Fans | 271

Reference:

Installation of DVV smoke extract roof fans.

extract fans
Smoke

Reference: State Theatre, Darmstadt, Germany

The Staatstheater in Darmstadt is one of the largest theatres in Germany. The building from the 1970s
was thoroughly renovated between 2002 and 2006. Particular attention was given to the new technical
building services and fire prevention.
Products/Solution: 11 axial fans HA 500, 1 axial fan AXC 500, 8 roof fans DVV 800 and various roof fans
DVS/DVN.
272 | Smoke Extract Fans

DVV/F Electrical
accessories
• 400°C/120 min. (F400) resp. 600°C/120 min. (F600)
• Vertical exhaust
• Suitable for coastal applications
• Certified acc. to EN 12101-3 AESp. 383
• CE-certified acc. to EN 12101-3, 2002-06
• Single speed high efficiency IE2 motors
• Available also as DVV/120 for continuous exhaust of medium
up to 120°C
FRQ p. 361
The DVV smoke extract fans are used in case of fire to extract
smoke gases from rooms, and also during normal working condi-

IE2 tions for standard ventilation.


Smoke-free escape ways increase the chances to rescue people
2009/640/EG FXDM p. 371
400°C 120min 600°C 120min in case of a fire. For installation only over heated rooms.
The octagonal casing is manufactured from seawater resist-
ant aluminium (DVV 1000 M and P 4 pole from aluzinc steel).
The base frame consist of galvanized steel. The impeller with
backward curved blades is manufactured from galvanized steel
Note: When choosing AES control respectively from stainless steel (F600).
please observe serial connecting Motor cooling with fresh air via air duct. Thermal motor protec-
capability of the service switch of tion PTC in single speed motors serial, in two speed motors up to
the DVV fan (instructions). Higher table respectively on request.
extract fans

connecting capability on request. For speed control use frequency inverters only with appropri-
ate filter to motor side. At frequency controlled units addition-
Smoke

al EMC protection may be needed (on request). In case of fire


any motor protective devices and frequency inverters must be
bridged to guarantee functionality.

Technical data
DVV/F 400D4 400D4-6 450D4 450D4-6 560D4 560D4-6 630D4-K 630D4-6-K 630D4 630D6
IE2 IE2 IE2 IE2 IE2
Art. no. F400 95360 95362 95366 95364 95370 95368 95182 3581 95184 95188
Art. no. F600 95359 95361 95365 95363 95369 95367 95181 3580 95183 95187
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power (P1) kW 0.78 0.78/0.27 1.31 1.31/0.58 2.32 2.35/0.73 3.6 3.6/1.44 6.7 2.57
Current A 1.6 1.7/0.8 2.6 3/1.4 3.5 4.6/3.7 6.6 6.9/3.3 11 5.5
Starting current A 6.6 6.8/2.4 12.5 10.8/5.9 20.3 23.9/13.3 36.7 38/13 95 25.3
Max. air flow m3/s 1.17 1.17/0.78 2.01 2.01/1.35 2.64 2.64/1.81 3.5 3.5/2.28 5.36 3.36
R.p.m. min-1 1390 1420/940 1400 1420/950 1420 1450/940 1400 1450/975 1455 935
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air for °C 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600
120 min.
Sound pressure level at 4 m dB(A) 62 62/53 66 66/55 69 69/60 71 71/61 75 64
Sound pressure level at 10 m dB(A) 52 52/43 56 56/46 59 59/52 63 63/53 69 58
Weight kg 49 49 69 72 78 84 129 138 144 134
Enclosure class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Thermal prot. PTC serial built-in yes - yes - yes - yes - yes yes
REV service switch serial yes yes yes yes yes yes yes yes yes yes
Wiring diagram p. 442-461 15c 15a 15c 15a 15c 15a 15c 15a 13c 15c
Smoke Extract Fans | 273

Dimensions Ventilation
accessories
F ød2 nxM
E*

C

E
ASFV p. 429

1 ød
ød
G

35 ASK/F p. 418
H

B
Shadowed area only for size DVV/F 400-560 A
* 1000D4-P, 4-6-P, 4-8-P have 2 cooling ducts ASSV/F
p. 428

DVV/F £A £B £C ød ød1 ød2 E F G H nxM


400 560 460 557 315 356 14 250 635 630 40 8xM8
450 710 600 706 355 395 14 270 808 700 20 8xM8 FDV/F p. 420
560 710 600 706 400 438 14 270 808 750 20 12xM8
630 995 880 990 500 541 18 225 1100 958 40 12xM8
800, 800-K 995 880 990 630 674 18 310 1272 1165 40 16xM10
800-M 995 880 990 630 674 18 280 1350 1280 40 16xM10
FDVE/F

extract fans
Smoke
800-P 995 880 990 630 674 18 280 1350 1280 40 16xM10 p. 420
1000 1160 1040 1154 710 751 18 325 1500 1350 70 16xM10
1000D6-M 1160 1040 1154 710 751 18 325 1500 1350 70 16xM10
1000D6-P 1160 1040 1154 710 751 18 325 1500 1350 70 16xM10
1000D4-M 1160 1040 1154 710 751 18 394 1500 1479 70 16xM10 FSL-DVV
p. 426
1000D4-P 1160 1040 1154 710 751 18 394 1500 1479 70 16xM10

VKV/F p. 428

VKVE/F
p. 428
DVV/F 630D4-6 800D4-K 800D4-6K 800D6 800D4-M 800D4-P 800D4-6-P 1000D8 1000D4-M 1000D6-M
IE2 IE2 IE2 IE2 IE2 IE2
Art. no. F400 3585 95199 30062 95192 95195 95197 30053 3668 95205 95207
Art. no. F600 3584 95200 30063 95191 95196 95198 30054 3667 95206 95208
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power (P1) kW 6.7/2.57 11 11.3/3.6 6.4 17.6 20 20/7.7 5.4 26.1 7.9
Current A 12/4.5 18 18.5/6.2 12.6 28.7 35 36/19 12.5 41 16
Starting current A 81.6/20.3 121 121/26 76 265 280 244/110 63.8 340 112
Max. air flow m3/s 5.36/3.36 7.08 7.08/5.0 7.08 9.58 10.8 10.8/7.25 9.44 14.2 9.42
R.p.m. min-1 1460/970 1445 1460/975 960 1470 1465 1460/985 710 1465 970
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air for °C 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600
120 min.
Sound pressure level at 4 m dB(A) 75/64 76 76/66 72 80 83 83/71 66 89 77
Sound pressure level at 10 m dB(A) 69/58 70 70/60 64 72 75 75/64 58 79 67
Weight kg 154 262 286 213 309 397 413 355 539 358
Enclosure class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Thermal prot. PTC serial built-in - yes - yes yes yes yes yes yes yes
REV service switch serial yes yes yes yes yes yes yes yes yes yes
Wiring diagram p. 442-461 15a 13c 15a 13c 13c 13c 13d 13c 13c 13c
274 | Smoke Extract Fans

Installation examples DVV fans Ventilation


accessories

DVV
DVV
HSDV p. 426

HSDV
FSL

ESDV p. 429
VKV/F
SSVE/F DVV
ASSV/F

SSV/F p. 425
VKVE/F
ASK/F

FDVE/F
VKV/F FDV/F

ASSV/F SSVE/F
p. 422
extract fans
Smoke

DVV/F 1000D4-6-M 1000D4-8-M 1000D6-8-M 1000D4-P 1000D6-P 1000D4-6-P 1000D4-8-P 1000D6 1000D6-8
IE2 IE2 IE2
Art. no. F400 33124 33126 33130 95203 95201 31266 31270 95194 3766
Art. no. F600 33125 33127 33131 95204 95213 31267 31271 95193 3765
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power (P1) kW 26.1/8.3 26.1/4.1 8.3/4.5 29.1 8.5 29.1/9.0 29.1/5.1 12.1 12.1/6.5
Current A 49/23 42/15 19/8.2 53.5 17.5 53.5/18 51/20 22 22/15
Starting current A 299/110 338/85 124/41 420 126 360/120 400/80 156 154/82.5
Max. air flow m3/s 14.2/9.42 14.2/7.08 9.42/7.08 15.2 10.1 15.2/10.1 15.2/7.56 12.4 12.4/9.44
R.p.m. min-1 1460/985 1460/730 980/740 1465 965 1470/980 1470/730 965 970/730
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air for °C 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600 400/600
120 min.

Sound pressure level at 4 m dB(A) 89/77 89/70 77/70 90 78 90/78 90/71 74 74/66
Sound pressure level at 10 m dB(A) 79/67 79/60 67/60 79 67 79/67 79/60 66 66/58
Weight kg 575 575 364 565 358 590 590 378 445
Enclosure class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Thermal prot. PTC serial built-in yes yes - yes yes yes yes yes yes
REV service switch serial yes yes yes yes yes yes yes yes yes
Wiring diagram p. 442-461 13d 14c 15a 13c 13c 13d 14c 13c 13d
Smoke Extract Fans | 275

Performance

DVV/F 450
DVV/F 400

4-pole
4-pole
81

71 6-pole 84

6-pole
75

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 81 54 66 74 75 74 72 69 61 LwA Inlet 84 57 69 77 78 77 75 72 64
LwA Surrounding 83 56 68 76 77 76 74 71 63 LwA Surrounding 86 59 71 79 80 79 77 74 66
Measurement point: 0.9 m³/s @ 200 Pa Measurement point: 1.7 m³/s @ 200 Pa

extract fans
Smoke
6-pole 6-pole
LwA Inlet 71 48 57 63 67 62 60 58 46 LwA Inlet 75 52 61 67 71 66 64 62 50
LwA Surrounding 73 50 59 65 69 64 62 60 48 LwA Surrounding 76 53 62 68 72 67 65 63 51
Measurement point: 0.4 m³/s @ 140 Pa Measurement point: 1.15 m³/s @ 100 Pa

0 2000 4000 6000 8000 10000

DVV/F 630-K
DVV/F 560

4-pole
4-pole

88
92

82
6-pole
6-pole

81

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 88 61 73 81 82 81 79 76 68 LwA Inlet 92 65 77 85 86 85 83 80 72

LwA Surrounding 90 63 75 83 84 83 81 78 70 LwA Surrounding 94 67 79 87 88 87 85 82 74

Measurement point: 2.1 m³/s @ 310 Pa Measurement point: 2.8 m³/s @ 400 Pa

6-pole 6-pole

LwA Inlet 81 58 67 73 77 72 70 68 56 LwA Inlet 82 58 69 71 78 73 72 68 55

LwA Surrounding 83 60 69 75 79 74 72 70 58 LwA Surrounding 84 60 71 73 80 75 74 70 57

Measurement point: 1.5 m³/s @ 125 Pa Measurement point: 1.38 m³/s @ 350 Pa
276 | Smoke Extract Fans

DVV/F 630 DVV/F 800-K

4-pole 4-pole
98

97
84
87
6-pole
6-pole

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 97 68 79 91 90 92 87 81 72 LwA Inlet 98 71 83 91 92 91 89 86 78
LwA Surrounding 98 68 87 88 91 91 91 89 79 LwA Surrounding 99 72 84 92 93 92 90 87 79
Measurement point: 4.58 m³/s @ 370 Pa Measurement point: 5.6 m³/s @ 740 Pa
6-pole 6-pole
extract fans

LwA Inlet 87 64 73 79 83 78 76 74 62 LwA Inlet 84 60 71 73 80 75 74 70 57


Smoke

LwA Surrounding 88 65 74 80 84 79 77 75 63 LwA Surrounding 86 62 73 75 82 77 76 72 59


Measurement point: 2.3 m³/s @ 290 Pa Measurement point: 4.0 m³/s @ 280 Pa

DVV/F 800 DVV/F 800-M

4-pole

6-pole

101

93

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
6-pole 4-pole
LwA Inlet 93 70 79 85 89 84 82 80 68 LwA Inlet 101 74 86 94 95 94 92 89 81
LwA Surrounding 95 72 81 87 91 86 84 82 70 LwA Surrounding 103 76 88 96 97 96 94 91 83
Measurement point: 6.1 m³/s @ 250 Pa Measurement point: 8.10 m³/s @ 740 Pa
Smoke Extract Fans | 277

DVV/F 800-P DVV/F 1000

4-pole 92

6-pole
104
8-pole
6-pole
84

91

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 6-pole
LwA Inlet 104 77 89 97 98 97 95 92 84 LwA Inlet 92 69 78 84 88 83 81 79 67
LwA Surrounding 106 79 91 99 100 99 97 94 86 LwA Surrounding 94 71 80 86 90 85 83 81 69
Measurement point: 8.6 m³/s @ 740 Pa Measurement point: 6.94 m³/s @ 650 Pa
6-pole 8-pole

extract fans
Smoke
LwA Inlet 91 67 78 80 87 82 81 77 64 LwA Inlet 84 66 72 75 79 76 76 71 60
LwA Surrounding 93 69 80 82 89 84 83 79 66 LwA Surrounding 86 68 74 77 81 78 78 73 62
Measurement point: 5.6 m³/s @ 330 Pa Measurement point: 6.11 m³/s @ 310 Pa

DVV/F 1000-M DVV/F 1000-P

104
105

4-pole 4-pole

6-pole 6-pole
92
8-pole 93

84
8-pole
84

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 104 82 91 97 100 96 94 92 80 LwA Inlet 105 82 91 97 101 96 94 92 80
LwA Surrounding 109 87 96 102 105 101 99 97 85 LwA Surrounding 110 87 96 102 106 101 99 97 85
Measurement point: 7.3 m³/s @ 1600 Pa Measurement point: 9.2 m³/s @ 1580 Pa
6-pole 6-pole
LwA Inlet 92 75 81 83 87 85 85 80 69 LwA Inlet 93 75 81 84 88 85 85 80 69
LwA Surrounding 97 80 86 88 92 90 90 85 74 LwA Surrounding 98 80 86 89 93 90 90 85 74
Measurement point: 4.8 m³/s @ 700 Pa Measurement point: 7.1 m³/s @ 560 Pa
8-pole 8-pole
LwA Inlet 84 66 72 75 79 76 76 71 60 LwA Inlet 84 66 72 75 79 76 76 71 60
LwA Surrounding 91 73 79 82 86 83 83 78 67 LwA Surrounding 91 73 79 82 86 83 83 78 67
Measurement point: 6.11 m³/s @ 430 Pa Measurement point: 6.1 m³/s @ 220 Pa
278 | Smoke Extract Fans

DVV-XS, XL NEW! Electrical


accessories
• Normal ventilation up to 120°C media (DVV/120) and smoke
and heat extract 400°C/120 min. (DVV/F400)
• Certified acc. to EN 12101-3
• CE-certification acc. to EN 12101-3, 2002-06 AES p. 383
• Meet ErP efficiency goal for dual use fans
• Vertical exhaust, suitable for coastal application
• Single speed high efficiency IE2 motors
• With service switch and PTC motor protection FRQ p. 361
• Inlet side connection acc. EUROVENT

The octagonal casing is manufactured from seawater resistant alu-


minium, the base frame of hot dip galvanized steel. The impeller
FXDM p. 371
120°C 400°C 120min
with backward curved blades is manufactured from galvanized steel.
Motor cooling with fresh air via air duct.
For speed control use frequency inverters only with appropriate
filter to motor side. For frequency controlled units additional EMC
protection may be needed (on request).
DVV-XS, XL were tested acc. EN 12101-3 together with frequency
inverter. In case of fire any motor protective devices and frequency
inverters without fire mode must be bridged to guarantee function-
ality.
extract fans

Quick selection
Smoke

Q [m³/h] Q [m³/h]
0 4000 8000 12000 16000 20000 0 10000 20000 30000 40000
1200 2000
DVV 630D-XL DVV 800D-XL
DVV 630D-XS DVV 800D-XS
4-pole DVV 1000-XL
4-pole
900 1500
Ps [Pa]
Ps [Pa]

6-pole
600 1000

6-pole
300 500
6-pole
8-pole
8-pole
0 0
0 1 2 3 4 5 6 0 2 4 6 8 10 12
Q [m³/s] Q [m³/s]

do not use in dotted area do not use in dotted area

Technical data
DVV-XS, XL 630D4-XS 630D6-XL 630D4-XL 630D4-6-XL 800D6-XS 800D6-8-XS 800D4-XS
Art. no. DVV/120 95321 95320 95318 95319 95327 95329 95326
Art. no. DVV/F400 95306 95305 95303 95304 95312 95314 95311
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y Y D Y/Y Y Y/Y D
Power (P1) kW 3.7 2.1 6.4 6.4/2.1 3.8 3.8/1.8 12.9
Current A 6.64 4.5 11 11/4.5 6.92 6.92/4.16 22
Starting current A 43 25 70 82/20 31 61/38 140
Max. air flow m³/s 4.17 3.78 5.81 5.81/3.78 5.64 5.64/4.36 8.75
R.p.m. 1/min 1441 940 1461 1461/940 932 932/734 1461
Max. temp. of transp. air °C 120 120 120 120 120 120 120
Max. temp. of transp. air °C 400 400 400 400 400 400 400
for 120 min.
Sound pressure level at 4/10 m dB(A) 71/63 64/58 75/69 75/69 / 64/58 66/60 66/60 / 55/48 76/70
Weight kg 123 123 137 138 224 233 260
Wiring diagram p. 442-461 15c 15c 13c 13d 15c 13d 13c

Insulation class, motor: F; Enclosure class, motor: IP 55


Smoke Extract Fans | 279

Dimensions Ventilation
Inlet side connection acc. EUROVENT. accessories

DVV 630-XS, XL / 1000-XL DVV 800-XS, XL

K I I
ASFV p. 429

ASG/F p. 418

H
H

ØG ASSG/F p. 429
ØG

ØF ØF

D
D
FDGE/F
p. 424

1
Ød
E nxM

M
nx
Ød1
Ød2
FDG/F p. 418

extract fans
Smoke
Ø
d2

A
B SSGE/F
C A
B
p. 424
C

DVV-XS, XL £A £B £C D E øF øG H I K ød1 ød2 nxM SSG/F p. 423


630 840 1035 1039 519.5 603 630 451 964 1100 240 690 14 12xM8
800* 1050 1251 1255 1630 - 800 581 1105 1350 - 860 14 16xM8
800** 1050 1251 1255 1630 - 800 581 1280 1350 - 860 14 16xM8
1000 1050 1251 1255 627.5 768 800 675 1490 1500 300 860 14 16xM8 VKG/F p. 428
* for 800D6-XS / 800D6-8-XS / 800D4-XS / 800D6-XL
** for 800D4-6-XS, 800D4-XL, 800D4-6-XL

FSL-DVV
p. 426

DVV-XS, XL 800D4-6-XS 800D6-XL 800D4-XL 800D4-6-XL 1000D6-XL 1000D6-8-XL 1000D8-XL


Art. no. DVV/120 95328 95323 95322 95324 95345 95346 95347
Art. no. DVV/F400 95313 95308 95307 95309 95342 95343 95344
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y/Y D D Y/Y D Y/Y D
Power (P1) kW 12.9/3.8 5.6 18.5 18.5/5.6 11.1 11.1/5.0 5.0
Current A 22/6.92 11.2 34.6 34.6/11.2 21.4 21.4/10.2 10.2
Starting current A 124/52 66 265 258/99 156 154/82.5 63.8
Max. air flow m³/s 8.75/5.64 7.36 11.1 11.1/7.36 12.5 12.5/9.44 9.44
R.p.m. 1/min 1461/932 955 1461 1461/955 977 977/730 730
Max. temp. of transp. air °C 120 120 120 120 120 120 120
Max. temp. of transp. air °C 400 400 400 400 400 400 400
for 120 min.
Sound pressure level at 4/10 m dB(A) 76/70 / 66/60 71/64 83/75 83/75 / 71/64 74/66 74/66 / 66/58 66/58
Weight kg 291 245 372 401 400 416 366
Wiring diagram p. 442-461 13d 13c 13c 13d 13c 13d 13c

Insulation class, motor: F; Enclosure class, motor: IP 55


280 | Smoke Extract Fans

DVG EC NEW! Electrical


accessories
• Normal ventilation and smoke and heat extract unit (dual use)
• Up to 400°C/120 min. (F400/120, F400/90, F300, F200)
• Normal ventilation up to 120°C continuous operation, up to 80°C in
standby (when the fan doesn`t operate) MTP p. 360
DVG-H
• Meets ErP efficiency goal for dual use fans
DVG-V
• Horizontal (DVG-H) exhaust or vertical exhaust (DVG-V)
• Suitable for coastal applications
• Certified acc. to EN 12101-3 MTV p. 359
• CE-certification acc. to EN 12101-3 : 2002-06
120°C
400°C 120min • 1~ (200-265V, 50/60Hz) or 3~ (342-506V, 50/60Hz)
• EC (electronically commutated) high efficiency motor
• 0-10V speed control input EC-Vent
• Modbus control possible p. 365
• Fire mode integrated

The DVG smoke extract fans are used in case of fire to extract smoke
gases from rooms, and also during normal working conditions for CO2RT-R-D
standard ventilation. p. 368
For installation only on top of heated buildings (SLO).
The casing is manufactured from seawater resistant aluminium. The
base frame consists of galvanized steel. The impeller with backward
extract fans

curved blades is manufactured from galvanized steel.


Motor outside air stream is cooled with fresh air. Includes on/off DSG p. 366
Smoke

Quick selection service switch.


Q [m³/h]
0 4000 8000 12000 16000 20000 24000 28000
1200

1100 1 DVG 355EC


2 DVG 450EC
1000
3 DVG 560 EC
900 4 DVG 630 EC
5 5 DVG 800 EC
800

700 DVG-H
Pstat [Pa]

DVG-V
600
3
500

400
4
300
2
1
200

100

0
0 1.11 2.22 3.33 4.44 5.56 6.67 7.78
Q [m³/s]

Technical data
DVG H 355EC H 450EC H 560EC H 630EC H 800EC V 355EC V 450EC V 560EC V 630EC V 800EC
F400 F400 F400 F400 F400 F400 F400 F400 F400 F400
Art. no. 95251 95252 95253 95254 95255 95256 95257 95135 95136 95137
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 400 3~ 400 3~ 400 3~ 230 1~ 230 1~ 400 3~ 400 3~ 400 3~
Power (P1) W 400 925 2420 5065 4865 400 925 2490 5055 4790
Current A 1.8 4 3.7 8 7.7 1.8 4 3.8 8 7.7
Max. air flow m³/s 0.903 1.72 3.64 5.33 7.67 0.861 1.61 3.42 5.06 6.97
R.p.m. 1/min 1500 1450 1400 1455 930 1500 1450 1400 1465 930
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120 120
* when speed-controlled °C 120 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air 120 min. °C 400 400 400 400 400 400 400 400 400 400
Sound pressure level at 4 m dB(A) 59 67 75 78 81 56 65 72 75 74
Sound pressure level at 10 m dB(A) 53 60 69 72 72 50 58 67 69 66
Weight kg 41 53 101 110 192 43 57 106 115 199
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 54 54 54 54 54 54 54 54 54 54
Wiring diagram p. 442-461 30 30 31 31 31 30 30 31 31 31
Smoke Extract Fans | 281

Dimensions Ventilation
accessories
DVG-H DVG-V
Max 240
B

ødf (nxM)
ødf (n x M) ASFV p. 429

A
ød

A
ød
ASG/F p. 418
øE

øE

B
ASSG/F p. 429
Max 240

G F

FDGE/F
p. 424
H

H
FDG/F p. 418

extract fans
Smoke
H1

H1
A A

SSGE/F
DVG £A £B øE F G ød ødf (n x M) H1 H
p. 424
355 EC 598 450 12 1003 704 400 438 (6xM8) 30 567
450 EC 668 535 12 1261 854 400 438 (6xM8) 30 637
560 EC 943 750 14 1540 1078 560 605 (8xM8) 30 773
630 EC 1039 840 14 1573 1072 630 674 (8xM8) 40 858 SSG/F p. 423
800 EC 1255 1050 14 2024 1280 800 872 (8xM8) 40 999

Performance
VKG/F p. 428
Q [m³/h] Q [m³/h]
0 1000 2000 3000 0 2000 4000 6000
500 800

DVG-H 355EC/F400 DVG-H 450EC/F400

400
600

300
Ps [Pa]
Ps [Pa]

400

200

200

100

0
0
0 0.5 1 1.5 2
0 0.25 0.5 0.75 1 Q [m³/s]
Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 81 54 74 74 72 73 72 67 64 LwA Inlet 86 56 71 73 78 85 73 66 63
LwA Outlet 77 55 66 73 68 70 69 64 54 LwA Outlet 88 61 74 78 83 83 77 70 66
Measurement point: 0.542 m³/s @ 340 Pa Measurement point: 1.03 m³/s @ 428 Pa
282 | Smoke Extract Fans

Q [m³/h] Q [m³/h]
0 4000 8000 12000 0 5000 10000 15000 20000
1000 1200

DVG-H 560EC/F400 DVG-H 630EC/F400

750 900

Ps [Pa]
Ps [Pa]

500 600

250 300

0 0
0 1 2 3 4 0 2 4 6
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 92 59 83 84 82 83 85 83 81 LwA Inlet 95 65 84 86 88 89 88 86 77
LwA Outlet 89 64 77 83 83 84 81 77 71 LwA Outlet 100 69 80 92 94 96 92 88 78
extract fans

Measurement point: 2.0 m³/s @ 647 Pa Measurement point: 3.73 m³/s @ 736 Pa
Smoke

Q [m³/h] Q [m³/h]
0 5000 10000 15000 20000 25000 0 1000 2000 3000
1000 500

DVG-H 800EC/F400 DVG-V 355EC/F400

400
750

300
Ps [Pa]
Ps [Pa]

500

200

250
100

0 0
0 2 4 6 8 0 0.25 0.5 0.75 1
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 94 53 63 79 85 87 90 84 81 LwA Inlet 81 54 74 74 72 73 72 67 64
LwA Outlet 97 45 69 81 91 93 91 83 74 LwA Outlet 76 53 65 72 67 69 66 60 50
Measurement point: 4.6 m³/s @ 580 Pa Measurement point: 0.517 m³/s @ 326 Pa
Smoke Extract Fans | 283

Q [m³/h] Q [m³/h]
0 2000 4000 6000 0 4000 8000 12000
800 1000

DVG-V 450EC/F400 DVG-V 560EC/F400

600 750
Ps [Pa]

Ps [Pa]
400 500

200 250

0 0
0 0.5 1 1.5 2 0 1 2 3 4
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 56 70 73 78 85 73 66 63 LwA Inlet 91 58 82 84 82 83 85 82 80
LwA Outlet 86 57 73 77 81 83 72 66 60 LwA Outlet 89 63 79 83 83 85 80 72 66

extract fans
Smoke
Measurement point: 0.967 m³/s @ 422 Pa Measurement point: 1.88 m³/s @ 674 Pa

Q [m³/h] Q [m³/h]
0 5000 10000 15000 20000 0 5000 10000 15000 20000 25000
1200 1000

DVG-V 630EC/F400 DVG-V 800EC/F400

900 750
Ps [Pa]

Ps [Pa]

600 500

300 250

0 0
0 2 4 6 0 2 4 6 8
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 95 65 84 86 88 88 88 86 76 LwA Inlet 93 52 63 78 84 86 90 83 81
LwA Outlet 95 66 77 89 88 90 85 79 69 LwA Outlet 92 40 64 73 85 89 85 75 65
Measurement point: 3.03 m³/s @ 822 Pa Measurement point: 4.18 m³/s @ 567 Pa
284 | Smoke Extract Fans

DVG/F Electrical
accessories
• Smoke and heat extract unit and normal ventilation (dual use)
• Up to 400°C/120 min. (F400/120, F400/90, F300, F200)
• Normal ventilation up to 120°C continuous operation
• Vertical exhaust DVG-V or horizontal DVG-H AES p. 383
• Service switch serial
• Suitable for coastal applications
• Certified acc. to EN 12101-3
• CE-certified acc. to EN 12101-3, 2002-06 FRQ p. 361

IE2
The DVG/F smoke extract fans are used in case of fire to extract
smoke gases from rooms, and also during normal working condi-
2009/640/EG
120°C 400°C 120min tions for standard ventilation.
The casing is manufactured from seawater resistant aluminium, FXDM p. 371
the base frame of galvanized steel. The impeller with backward
curved blades is manufactured from galvanized steel.
The motor outside the air stream is cooled with fresh air. Thermal
motor protection PTC in single speed motors serial, in two speed
Note: Diagrams and data of max. airflow motors PTC or thermal contact (if using two speed switch S-DT2...)
and sound level refer to items with verti- on request.
cal exhaust DVG-V; diagrams and data of DVG fans were tested together with frequency inverter. Use fre-
DVG-H are available online. Data related quency inverter only with appropriate filter to motor side. For fre-
to motor and weight of delivered items quency controlled units additional EMC protection may be needed
extract fans

can vary from catalogue data. (on request). In case of fire, any motor protection devices and fre-
quency inverters without fire mode must be bridged to guarantee
Smoke

functionality.

Technical data
DVG/F 315D4 315D4-8 355D4 355D4-8 400D4-S 400D4-8-S 400D4 400D4-8 450D4 IE2
Art. no. DVG-V (vertical) 32306 32307 32308 32309 32310 32311 32312 32313 95164
Art. no. DVG-H (horizontal) 95001 95002 95003 95004 95005 95006 95007 95008 95153
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y YY/Y Y YY/Y Y YY/Y Y YY/Y Y
Power (P1) W 227 360/140 372 372/160 495 495/206 660 795/205 927
Current A 0.95 1.3/0.6 0.95 1.3/0.6 0.95 1.3/0.6 1.6 1.3/0.6 1.88
Starting current A 4.1 4.4/1.3 4.1 4.4/1.3 4.1 3.4/1.3 6.6 5.8/1.3 10.1
Max. air flow m3/s 0.71 0.71/0.36 0.81 0.81/0.38 0.97 0.97/0.49 1.31 1.31/0.66 1.52
R.p.m. min-1 1405 1430/660 1405 1430/660 1405 1430/660 1390 1380/685 1415
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air 120 min. °C 400 400 400 400 400 400 400 400 400
Sound pressure level at 4 m dB(A) 55 55/39 56 56/41 59 59/43 62 62/46 65
Sound pressure level at 10 m dB(A) 49 49/33 50 50/35 53 53/37 55 55/40 58
Weight kg 41 41/39 43 43/41 43 45/43 46 46/44 56
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
PTC serial built-in motor yes - yes - yes - yes - yes
S-DT2DKT, S-DT2GKT - ...DKT - ...DKT - ...DKT - ...DKT -
FXDM ...5AM - ...5AM - ...5AM - ...5AM - ...5AM
Wiring diagram p. 442-461 15c 14d 15c 14d 15c 14d 15c 14d 15c
Smoke Extract Fans | 285

Quick selection Ventilation


accessories

8178, 8284, 8180, 8177, 8181, 8176, 8182

8199, 8183, 8174, 8184, 8172, 8173, 8185, 8186


1 DVG/F 315D4 4 DVG/F 355D8 1 DVG/F 400D4 4 DVG/F 450D8
DVG/F 315D8 DVG/F 400D4-S 2 DVG/F 400D8 DVG/F 500D4 IE2
2 5 5
ASFV p. 429
3 DVG/F 355D4 6 DVG/F 400D8-S 3 DVG/F 450D4 IE2 6 DVG/F 500D4-S IE2
7 DVG/F 500D8-S
8 DVG/F 500D8
5

3
6
ASG/F p. 418
1 3

5 1

ASSG/F
8
2 4 2 4 7 p. 429
6

FDGE/F
p. 424

FDG/F p. 418
8171, 8187, 8191, 8161, 8170, 8194, 8195

8193, 8194, 8196, 9856, 9858, 9656, 9935

extract fans
Smoke
1 DVG-F 560D4 IE2 4 DVG-F 630D4-S 1 DVG-F 630D4 IE2 4 DVG-F 630D8
2 DVG-F 560D8 5 DVG-F 630D6-S 2 DVG-F 630D6-S 5 DVG-F 800D6-S IE2
3 DVG-F 560D6 IE2 6 DVG-F 630D8-S 3 DVG-F 630D6-IE2 6 DVG-F 800D8-S
7 DVG-F 800D6 IE2
8 DVG-F 800D8

SSGE/F
1 4 p. 424
5
1 7

5
3 2 8
6
SSG/F p. 423
2 4
3
6

VKG/F p. 428

DVG/F 450D4-8 500D4-S IE2 500D4-8-S 500D4 IE2 500D4-8 560D4 IE2 560D4-8 560D6 IE2 630D4-S IE2
Art. no. V (vertical) 32315 95166 32317 95165 32319 95169 32323 95170 95172
Art. no. H (horizontal) 95010 95155 95012 95154 95014 95158 95018 95159 95161
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection YY/Y Y YY/Y Y YY/Y Y YY/Y Y D or Y
Power W 927/374 1100 1100/524 1752 1752/585 2200 2500/855 750 3587
Current A 3.1/1.25 2.6 3.1/1.25 3.5 3.5/1.4 5.35 5.9/2.4 2 6.65
Starting current A 12.4/3 12.5 12.4/3.0 20.3 14.4/3.5 28.9 30.7/7.4 5.8 36.7
Max. air flow m3/s 1.52/0.76 2 2.0/1.0 2.64 2.64/1.32 3.24 3.24/1.6 2.11 3.82
R.p.m. min-1 1400/690 1400 1400/690 1420 1400/680 1435 1430/710 880 1400
Max. temp. of transp. air °C 120 120 120 120 120 120 120 120 120
Max. temp. of transp. air 120 min. °C 400 400 400 400 400 400 400 400 400
Sound pressure level at 4 m dB(A) 65/49 66 66/51 70 70/52 72 72/53 58 71
Sound pressure level at 10 m dB(A) 58/43 60 60/45 63 63/46 67 67/47 52 65
Weight kg 58 87 87 86 86 104 107 96 119
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
PTC serial built-in motor - yes - yes - yes - yes yes
S-DT2DKT, S-DT2GKT ...DKT - ...DKT - ...DKT - ...DKT - -
FXDM... - ...5AM - ...5AM - ...8AM - ...5AM ...8AM
Wiring diagram p. 442-461 14d 15c 14d 15c 14d 15c 14d 15c 15c
286 | Smoke Extract Fans

Dimensions
DVG-V/F DVG-H/F
B
Max 240

ødf (n x M) ødf (nxM)

A
ød

A
ød

øE

øE

Max 240
B
DVG/F £A £B øE F G ød ødf (n x M) H1 H
315 598 450 12 891 594 400 438 (6xM8) 30 520
F 355 598 450 12 1003 704 400 438 (6xM8) 30 567
G
400 668 535 12 1053 724 400 438 (6xM8) 30 557
450 668 535 12 1261 854 400 438 (6xM8) 30 637
500 943 750 14 1343 892 560 605 (8xM8) 30 696
560 943 750 14 1540 1078 560 605 (8xM8) 30 773
H

H
630 1039 840 14 1573 1072 630 674 (8xM8) 40 858

H1
800 1255 1050 14 2024 1280 800 872 (8xM8) 40 999
H1

A A

DVG/F 630D4 IE2 630D4-8-S 630D6-S IE2 630D6-8-S 630D4-8 630D6 IE2
Art. no. DVG-V (vertical) 95171 32328 95174 32326 32333 95173
Art. no. DVG-H (horizontal 95160 95023 95163 95021 95028 95162
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
extract fans

Connection D YY/Y Y Y/Y YY/Y Y


Smoke

Power W 4000 3794/573 1082 1082/573 4922/712 1571


Current A 8.65 7.5/3.0 2.9 3.3/1.35 9.5/3.5 3.8
Starting current A 51 44/10.0 10.8 14.2/4.7 57/12.3 18.6
Max. air flow m3/s 4.91 3.82/1.89 2.45 2.45/1.89 4.91/2.47 3.19
R.p.m. min-1 1440 1435/705 910 950/710 1450/720 945
Max. temp. of transp. air °C 120 120 120 120 120 120
Max. temp. of transp. air 120 min. °C 400 400 400 400 400 400
Sound pressure level at 4 m dB(A) 75 71/55 62 62/55 75/59 66
Sound pressure level at 10 m dB(A) 69 65/49 56 55/49 69/54 60
Weight kg 128 128 111 117 144 115
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 54
PTC serial built-in motor yes - yes - - yes
S-DT2DKT, S-DT2GKT - ...DKT - ...GKT ...DKT -
FXDM... ...14AM - ...5AM - - ...5AM
Wiring diagram p. 442-461 15c 14d 15c 15a 14d 15c

DVG/F 800D6-S IE2 800D6-8-S 800D6 IE2 800D8


Art. no. DVG-V (vertical) 95131 95132 95128 95129
Art. no. DVG-H (horizontal 95126 95127 95122 95124
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~
Connection D or Y Y/Y D Y
Power W 3444 3444/1694 5857 2709
Current A 6.8 7.5/3.8 12.6 5.5
Starting current A 34.7 38.3/15.6 76 25.2
Max. air flow m3/s 5.28 5.29/4.00 7.08 5.28
R.p.m. min-1 950 970/730 960 690
Max. temp. of transp. air °C 120 120 120 120
Max. temp. of transp. air 120 min. °C 400 400 400 400
Sound pressure level at 4 m dB(A) 71 71/63 74 68
Sound pressure level at 10 m dB(A) 64 64/56 66 60
Weight kg 202 208 212 198
Enclosure class, motor IP 54 IP 54 IP 54 IP 54
PTC serial built-in motor yes - yes -
S-DT2DKT, S-DT2GKT - ...GKT - -
FXDM... ...8AM - ...14AM -
Wiring diagram p. 442-461 15c 15a 13c 15b
Smoke Extract Fans | 287

Performance
qv [m³/h] qv [m³/h]

DVG-V 315/F DVG-V 355/F

4-pole
4-pole

8-pole
8-pole

qv [m³/s] qv [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 78 51 72 72 69 71 69 64 61 LwA Inlet 81 55 75 75 73 74 73 67 64
LwA Surrounding 76 54 65 72 67 69 67 61 51 LwA Surrounding 77 55 67 74 69 71 68 62 52
Measurement point: 0.6 m³/s @ 80 Pa Measurement point: 0.6 m³/s @ 200 Pa

extract fans
Smoke
8-pole 8-pole
LwA Inlet 62 40 58 54 54 53 53 45 36 LwA Inlet 65 43 61 57 57 56 56 48 39
LwA Surrounding 60 44 52 53 53 55 50 42 33 LwA Surrounding 62 46 54 55 55 57 52 44 35
Measurement point: 0.2 m³/s @ 50 Pa Measurement point: 0.3 m³/s @ 50 Pa

qv [m³/h] qv [m³/h]

DVG-V 400-S/F DVG-V 400/F

4-pole 4-pole

8-pole
8-pole

qv [m³/s] qv [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

4-pole 4-pole
LwA Inlet 82 55 76 76 73 75 73 68 65 LwA Inlet 85 58 79 79 76 78 76 71 68
LwA Sorrounding 82 60 71 78 73 75 73 67 57 LwA Surrounding 85 63 74 81 76 78 76 70 60

Measurement point: 0.7 m³/s @ 220 Pa Measurement point: 1.1 m³/s @ 125 Pa
8-pole 8-pole
LwA Inlet 66 44 62 58 58 57 57 49 40 LwA Inlet 69 47 65 61 61 60 60 52 43
LwA Surrounding 66 50 58 59 59 61 56 48 39 LwA Surrounding 68 52 60 61 61 63 58 50 41
Measurement point: 0.4 m³/s @ 50 Pa Measurement point: 0.5 m³/s @ 50 Pa
288 | Smoke Extract Fans

qv [m³/h] qv [m³/h]

DVG-V 450/F DVG-V 500-S/F


4-pole
4-pole

8-pole 8-pole

qv [m³/s] qv [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 88 56 71 73 78 86 74 67 63 LwA Inlet 88 61 81 81 79 81 78 79 66
LwA Surrounding 87 57 73 77 81 84 73 67 60 LwA Surrounding 88 63 76 81 80 84 78 73 62
Measurement point: 1.2 m³/s @ 200 Pa Measurement point: 1.2 m³/s @ 500 Pa
extract fans

8-pole 8-pole
LwA Inlet 71 50 61 63 61 67 62 62 50 LwA Inlet 72 53 62 64 63 66 67 55 45
Smoke

LwA Surrounding 69 52 58 63 62 63 59 56 39 LwA Surrounding 69 52 59 62 63 65 61 52 40


Measurement point: 0.6 m³/s @ 50 Pa Measurement point: 0.6 m³/s @ 130 Pa

qv [m³/h] qv [m³/h]

DVG-V 500/F DVG-V 560/F


4-pole
4-pole

6-pole

8-pole
8-pole

qv [m³/s] qv [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 90 61 74 84 83 83 84 81 74 LwA Inlet 94 59 85 86 84 85 87 84 82

LwA Surrounding 91 64 75 86 83 87 82 76 65 LwA Surrounding 94 67 84 88 88 89 85 77 70

Measurement point: 2.1 m³/s @ 300 Pa Measurement point: 2.5 m³/s @ 400 Pa

8-pole 6-pole

LwA Inlet 72 50 68 64 64 63 63 55 46 LwA Inlet 87 57 80 80 80 79 80 71 64

LwA Surrounding 73 57 65 66 66 68 63 55 46 LwA Surrounding 82 61 73 77 74 75 74 66 58

Measurement point: 1.1 m³/s @ 50 Pa Measurement point: 1.8 m³/s @ 100 Pa


8-pole
LwA Inlet 76 55 65 68 66 72 67 67 55
LwA Surrounding 74 58 64 69 67 69 65 61 44
Measurement point: 1.5 m³/s @ 50 Pa
Smoke Extract Fans | 289

qv [m³/h] qv [m³/h]

DVG-V 630-S/F DVG-V 630/F

4-pole

4-pole

6-pole
6-pole

8-pole 8-pole

qv [m³/s] qv [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
4-pole 4-pole
LwA Inlet 94 60 86 80 83 87 87 87 72 LwA Inlet 97 68 79 91 90 92 87 81 72
LwA Surrounding 93 66 84 84 86 88 84 79 68 LwA Surrounding 96 66 85 86 89 89 89 87 77
Measurement point: 2.8 m³/s @ 500 Pa Measurement point: 3.8 m³/s @ 500 Pa

extract fans
Smoke
6-pole 6-pole
LwA Inlet 85 55 78 78 78 77 78 70 62 LwA Inlet 87 57 80 80 80 79 80 71 64
LwA Surrounding 84 63 74 78 77 79 75 67 57 LwA Surrounding 89 69 79 83 82 84 80 72 62
Measurement point: 2.2 m³/s @ 100 Pa Measurement point: 2.8 m³/s @ 120 Pa
8-pole 8-pole
LwA Inlet 78 56 74 70 70 69 69 61 52 LwA Inlet 81 59 77 73 73 72 72 64 55
LwA Surrounding 77 61 69 70 70 72 67 59 50 LwA Surrounding 82 66 74 75 75 77 72 64 55
Measurement point: 1.7 m³/s @ 60 Pa Measurement point: 2.1 m³/s @ 80 Pa

DVG-V 800-S/F DVG-V 800/F

6-pole

8-pole

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
6-pole 6-pole
LwA Inlet 88 48 64 69 78 81 84 83 70 LwA Inlet 96 55 65 81 87 89 93 86 83
LwA Surrounding 91 56 70 76 84 88 84 79 64 LwA Surrounding 94 42 65 75 87 91 87 77 67
Measurement point: 4.2 m³/s @ 300 Pa Measurement point: 5.4 m³/s @ 400 Pa

8-pole 8-pole

LwA Inlet 82 34 58 64 70 76 79 70 67 LwA Inlet 90 48 62 70 79 88 84 77 71


LwA Surrounding 83 45 61 68 77 79 75 68 69 LwA Surrounding 87 42 59 70 82 84 77 69 63
Measurement point: 3.6 m³/s @ 100 Pa Measurement point: 3.9 m³/s @ 250 Pa
Installation examples DVG

1 DVG-V Roof fan


1
2 SSG/F Flat roof socket silencer

3 ASG/F Inlet chamber

2 4 VKG/F Automatic shutter

5 ASSG/F Flexible connection

6 FDG/F Flat roof socket


3 SSGE/F Roof socket silencer
7

5
extract fans
Smoke

1
1

4
4

2
7

3
3

5 5
Installation examples DVV-XS, XL smoke extract fans
See p. 278, installation examples of other DVV fans on page 274

FSL

VKG/F VKG/F

SSG/F

SSG/F VKG/F
FDGE/F
SSGE/F ASSG/F
ASG/F
FDG/F
ASG/F
VKG/F
ASG/F
ASSG/F
ASSG/F

extract fans
Smoke
ASSG/F

Installation example axial fans


See p. 302

7 15
16

1 12
6 13
2 14

3
4
5 1
1 SG Protection guard
2 ESD-F Inlet cone 8
Smoke extract fans

3 RSA Silencer
4 EV Flexible connection 9 10
11
5 MPR Mounting ring
6 AXC Axial fan
7 MP Mounting brackets
8 MFA Mounting feet 12 LRK Air operated damper

SD Rubber mounts 13 GFL Counterflange


9
14 ABS Outlet cowl
10 FSD Spring mounts
15 REV On/Off switch
11 ZSD Spring mounts for
tensile load 16 REV(F) On/Off switch
292 | Smoke Extract Fans

NEW!
kvb/F
• Certified in accordance with EN 12101-3 for 400°C/120 min.
• Belt driven fan with motor out of the air stream
• Forward curved double inlet galvanized steel impeller
• Galvanized steel single skin box
• IP 55, B3, class F, 3~ IEC Motor
• Inline operation
• With single or two speed motors

The KVB/F range covers airflows from 1 000 to 50 000 m3/h, for indoor and outdoor
installation
400°C 120min
Applications: Industrial kitchen extract, malls, cinemas, theaters, garages (extract and
intake).
Operations: 50/60 Hz (belt adjusted to the working point).

Accessories: Outlet hood, roof, ON/OFF isolator (on request).

Selection program on www.systemair.com


extract fans

Dimensions
Smoke

B 44 A 44
= F = = D =
H
=

G
C
E
=

Inlet Outlet
KVB/F A B C K
E F G H
9/9 760 785 595 45 306 272 455 395
10/10 825 850 615 45 334 297 555 415
12/12 945 920 680 45 394 349 655 480
15/15 1100 1100 775 45 481 411 705 575
18/18 1250 1280 900 80 564 487 905 700
20/20 1475 1495 1080 80 610 611 955 880
22/22 1625 1640 1180 80 663 702 1055 980
25/25 1825 1800 1300 80 773 801 1255 1100
30/28 2135 2000 1525 80 898 940 1455 1325
Smoke Extract Fans | 293

Technical data

Amp. max. Installed Amp. max. Installed


Speed Air flow Speed Air flow
Model power Model power
230V(A) 400V [r.p.m.] [m3/h] 230V(A) 400V [r.p.m.] [m3/h]
[kW] [kW]

KVB/F-9/9 1.78 1.03 0.37 1020 2200 KVB/F-22/22 8.48 4.83 2.2 430 15000

KVB/F-9/9 2.51 1.45 0.55 1050 2900 KVB/F-22/22 11.07 6.33 3 480 17000

KVB/F-9/9 3.22 1.79 0.75 1070 3200 KVB/F-22/22 14.36 8.23 4 500 19000

KVB/F-9/9 4.58 2.50 1.1 1260 3750 KVB/F-22/22 19.72 10.90 5.5 580 21500

KVB/F-10/10 1.78 1.03 0.37 845 2950 KVB/F-22/22 26.12 14.50 7.5 610 22000

KVB/F-10/10 2.51 1.45 0.55 845 3800 KVB/F-22/22 37.02 20.80 11 740 27000

KVB/F-10/10 3.22 1.79 0.75 960 4175 KVB/F-25/25 8.48 4.83 2.2 375 17000

KVB/F-10/10 4.58 2.50 1.1 1070 4800 KVB/F-25/25 11.07 6.33 3 405 20500

KVB/F-10/10 5.97 3.31 1.5 1140 5400 KVB/F-25/25 14.36 8.23 4 450 22000

KVB/F-12/12 1.78 1.03 0.37 595 4200 KVB/F-25/25 19.72 10.90 5.5 485 24500

KVB/F-12/12 2.51 1.45 0.55 675 4800 KVB/F-25/25 26.12 14.50 7.5 545 28000

KVB/F-12/12 3.22 1.79 0.75 765 5400 KVB/F-25/25 37.02 20.80 11 610 32000

KVB/F-12/12 4.58 2.50 1.1 855 5800 KVB/F-25/25 49.31 27.80 15 640 37000

extract fans
Smoke
KVB/F-12/12 5.97 3.31 1.5 965 6500 KVB/F-30/28 11.07 6.33 3 360 22000

KVB/F-12/12 8.48 4.83 2.2 1100 8000 KVB/F-30/28 14.36 8.23 4 380 25000

KVB/F-15/15 2.51 1.45 0.55 525 5900 KVB/F-30/28 19.72 10.90 5.5 395 31500

KVB/F-15/15 3.22 1.79 0.75 595 6500 KVB/F-30/28 26.12 14.50 7.5 410 36000

KVB/F-15/15 4.58 2.50 1.1 635 7500 KVB/F-30/28 37.07 20.80 11 480 42000

KVB/F-15/15 5.97 3.31 1.5 700 8200 KVB/F-30/28 49.31 27.80 15 520 48000

KVB/F-15/15 8.48 4.83 2.2 800 9500

KVB/F-15/15 11.03 6.33 3 900 10600


Performance
KVB/F-15/15 14.36 8.23 4 990 12000 9-9
KVB/F-18/18 4.58 2.50 1.1 500 9000 150
140 60%
67%
70% 69% 63%
130 53%
η
120
KVB/F-18/18 5.67 3.31 1.5 540 9250 110
100 2400
KVB/F-18/18 8.48 4.83 2.2 590 11500 90
80
KVB/F-18/18 11.07 6.33 3 640 13200 70 2000

60
KVB/F-18/18 14.36 8.23 4 720 15000 1800

50
KVB/F-18/18 19.72 10.90 5.5 850 17000 1600

40 1500

KVB/F-20/20 8.48 4.83 2.2 500 12800 1400

30 1300
KVB/F-20/20 11.07 6.33 3 570 14200
1200

KVB/F-20/20 14.36 8.23 4 630 15500 1100


20

KVB/F-20/20 19.72 10.90 5.5 670 17500 1000

900
KVB/F-20/20 26.12 14.50 7.5 760 20000
800
10

700

Not usable
600 Not recommended
Not recommended

V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000
3

C 2 (m/s) 2 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70
294 | Smoke Extract Fans

Performance

10-10 12-12
150 150
140 140
130 62% 56% 130 68% 60% 1800
120 65% 120
2200 47% 69%
110 64% 110
60% η 65%
100 η 100
1500
90 1800 90
1700 1400
80 80

70 70 1300
1600
60 60 1200
1500

50 1400 50 1100

1300
40 40 1000
1200
900
30 1100 30

800
1000

20 900 20 700

800
600

700

10 10 500
600

Not usable Not usable


extract fans

Not recommended Not recommended


Not recommended Not recommended
Smoke

V(m /h) 500 1000 1500 2000 3000 4000 6000 8000 10000 V(m /h) 1000 1500 2000 3000 4000 6000 8000 10000 15000 20000
3 3

C 2 (m/s) 2 3 4 5 10 15 20 30 C 2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

15-15 18-18
150 150
140 64% 65% 140
130 η 58% 62% 54% 130
71%
1200
120 1400 120 73% 64%
110 110 70%
100 100 η
1200
90 90
1000
80 1100 80

70 70 900
1000
60 60
800
900
50 50

800 700
40 40

700 600
30 30

600
500
20 20

450
500

400

10 400 10 350

Not usable Not usable


Not recommended Not recommended
Not recommended Not recommended

V(m /h) 1500 2000 3000 4000 6000 8000 10000 15000 20000 30000 V(m /h) 2000 3000 4000 6000 800010000 15000 20000 30000 40000
3 3

C 2 (m/s) 3 4 5 10 15 20 30 40 C 2 (m/s) 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70


Smoke Extract Fans | 295

20-20 22-22
120 120 8.0
6.0
110 5.0 1200 110 64% 1200
Not usable 6.0 h 65%
Not usable 1000 68% 54% 1000

11
100 100

9.
Not recommended Not recommended

.5
4.0 70% 70% 5.0

0
90 64% 900 90 900
Not recommended 65% Not recommended
800 900 800
80 52% 80 4.0
3.0 h 1000
70 700 70 700
3.0
900 600 600
60 2.0 60
800
50 500 50 2.0 500
1.5 800

700
400 1.5 400
40 40
1.0 700

0.8 1.0 600


)

300 300
kW

30 30

Dpt (mm H 2O )
Dpt (mm H 2O )

PA (

)
600

kW

P a (N /m )
P a (N /m )
0.8

2
2
0.6

PA (
0.5
0.6 500
20 200 20 200
0.4
500
)

450
-1

0.4
min

0.3
450
n(

)
-1
400

min
400

n(
350 100
10 100 10
350

300

300

extract fans
Smoke
2000 3000 4000 6000 8000 10000 15000 20000 30000 40000 V(m /h)
3
2000 3000 4000 6000 8000 10000 15000 20000 30000 40000 V(m3/h)
C 2 (m/s) 2 3 4 5 10 15 20 30 C 2 (m/s) 2 3 4 5 10 15 20

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50

25-25 30-28
120 120 15 78%
69% 66% 75% 67% 1200
10 1200 110
110 54% 10 h 73%
67% 13 1000 1000
100
8.0 h 100
90 900 90 8.0 900
600
80 800 80 800
6.0
6.0 550
5.0 700 700 70 700
70
5.0
650 600 500 600
60 4.0 60
4.0
600 500
50 3.0 500 50 450
3.0
550
)

400 400
kW

40 40 400
)

2.0
PA (

kW

500 2.0
PA (

1.5 300 30 350 300


30 450 1.5
Dpt (mm H 2O )
Dpt (mm H 2O )

P a (N /m )
P a (N /m )

2
2

1.0 400 1.0 300


20 0.8 200 20 200
0.8
350
)
)

-1
-1

0.6
min
min

0.6
250
n(
n(

300
0.4

10 100 10 100
200
250

Not usable Not usable


Not recommended Not recommended
Not recommended Not recommended

5000 10000 15000 20000 30000 40000 60000 80000 100000 V(m3/h) 5000 10000 15000 20000 30000 40000 60000 80000 100000 V(m3/h)
C 2 (m/s) 3 4 5 10 15 20 30 40 C 2 (m/s) 2 3 4 5 10 15 20 30 40

pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70 pd (mm H2O) 1 2 3 4 5 10 20 30 40 50 70

Note: All fan curves are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point.
296 | Smoke Extract Fans

MUB/F Electrical
accessories
• Smoke extract fan, also suitable for daily ventilation purposes
• 400°/120 min. (F400)
• Insulated casing
• Low sound level AES p. 383
• Certified according to EN 12101-3

The smoke extract units MUB/F are used in case of fire to extract
smoke gases from rooms, and also during normal working conditions FRQ p. 361
for standard temperature up to 55°C continuously.
The MUB/F units have backward curved impellers made of galva-
nized steel. The outlet can be easily changed on site from straight
to side outlet. The frame is manufactured from profiled steel. The
400°C 120min
galvanized steel panels are double skin panels with mineral wool in-
sulation.
Motors are high temperature motors for temperature classification
F 400/120 min. Single or double speed versions available.
For outdoor installations with weather roof as accessory.

Quick selection
extract fans
Smoke

1 MUB/F 042 400D4 1 MUB/F 062 560D4


2 MUB/F 042 400D6 2 MUB/F 062 560D6
3 MUB/F 042 450D4 3 MUB/F 062 630D4
4 MUB/F 042 450D6 4 MUB/F 062 630D6
5 MUB/F 062 500D4
6 MUB/F 062 500D6

2 4 6 1 3 5
2 4 1 3

Technical data
MUB/F 042 400D4 042 400D4-6 042 450D4 042 450D4-6 062 500D4 062 500D4-6
Art. no. 33290 33292 33293 33295 33296 33298
Techn. data is relating to 90° outlet
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y YY/Y Y YY/Y Y YY/Y
Power (P1) W 629 629/273 858 858/372 1749 1749/728
Current A 1.3 1.32/0.795 1.63 1.63/0.904 3.26 3.26/1.76
Starting current A 7.2 2.6/2 9.8 13.1/3.8 19.8 26.7/7.1
Max. air flow m3/s 1.49 1.49/0.99 1.58 1.58/1.04 2.27 2.27/1.53
R.p.m. min-1 1461 1461/980 1446 1446/971 1440 1440/967
Max. temp. of transported air °C 55 55 55 55 55 55
Max. temp. of transported air for 120 min. °C 400 400 400 400 400 400
Sound pressure level at 3 m dB(A) 55 55/47 57 57/49 66 66/55
Sound pressure level at 4 m dB(A) 39 39/31 41 41/33 50 50/39
Sound pressure level at 10 m dB(A) 31 31/23 33 33/25 42 42/31
Weight kg 86 92 94 97 119 136
Insulation class, motor HC HC HC HC HC HC
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 10 14a 10 14a 10 14a
Smoke Extract Fans | 297

Dimensions Ventilation
accessories

MUB/F £A £B £C £D øE øH øI J max. EVH p. 436


42 400 670 670 590 548 410 400 289 783
42 450 670 670 590 548 454 400 289 783
62 500 800 800 720 676 520 560 364 915

A
62 560 800 800 720 676 570 560 364 915 SDM p. 412

J
62 630 800 800 720 676 650 630 456 915

GFL-AR/AXC
p. 437

øI
øH
LRK p. 430
øE
D
C WSD p. 413

B

extract fans
Smoke
RSA p. 430

MUB/F 062 560D4 062 560D4-6 062 630D4 062 630D6 062 630D4-6
Art. no. 33299 33301 33302 33303 33304
Techn. data is relating to 90° outlet
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y YY/Y D Y YY/Y
Power (P1) W 2501 2501/964 4852 1689 4852/1689
Current A 4.58 4.58/2.47 8.58 3.93 8.58/3.93
Starting current A 29 36.3/10 56.6 22 74/19.8
Max. air flow m /s 2.66
3
2.66/1.77 3.83 2.52 3.83/2.52
R.p.m. min-1 1440 1440/972 1459 979 1459/979
Max. temp. of transported air °C 55 55 55 55 55
Max. temp. of transported air for 120 min. °C 400 400 400 400 400
Sound pressure level at 3 m dB(A) 69 69/58 75 64 75/64
Sound pressure level at 4 m dB(A) 53 53/42 59 48 59/48
Sound pressure level at 10 m dB(A) 45 45/34 51 40 51/40
Weight kg 134 155 163 158 190
Insulation class, motor HC HC HC HC HC
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 10 14a 13a 10 14a
298 | Smoke Extract Fans

Performance

MUB 042 400D4/F MUB 042 400D4/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
extract fans

LwA Inlet 77 63 72 71 70 69 65 62 57 LwA Inlet 77 61 68 72 71 69 67 65 59


LwA Outlet 73 62 64 63 64 66 66 61 55 LwA Outlet 79 63 71 72 72 73 72 67 60
Smoke

LwA Surrounding 61 35 50 60 50 50 45 40 36 LwA Surrounding 62 42 49 61 51 50 47 43 38


Measurement point: 0.636 m³/s @ 312 Pa Measurement point: 0.819 m³/s @ 334 Pa

MUB 042 450D4/F


MUB 042 450D4/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 81 63 69 69 71 71 75 75 67 LwA Inlet 80 45 69 68 71 72 74 74 65
LwA Outlet 76 42 60 62 67 69 71 70 61 LwA Outlet 79 53 67 68 72 72 72 71 61
LwA Surrounding 65 49 56 61 54 56 55 55 49 LwA Surrounding 64 31 58 58 54 57 53 54 47
Measurement point: 0.755 m³/s @ 405 Pa Measurement point: 0.869 m³/s @ 493 Pa
Smoke Extract Fans | 299

MUB 062 500D4/F MUB 062 500D4/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

extract fans
Smoke
LwA Inlet 84 68 77 78 78 74 75 74 65 LwA Inlet 85 69 78 78 78 75 75 74 65
LwA Outlet 79 55 64 65 71 75 73 71 61 LwA Outlet 80 57 68 70 72 75 73 72 63
LwA Surrounding 73 50 65 70 61 62 64 61 46 LwA Surrounding 73 51 65 70 62 62 65 61 46
Measurement point: 1.17 m³/s @ 472 Pa Measurement point: 1.14 m³/s @ 536 Pa

MUB 062 500D6/F MUB 062 500D6/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 61 69 65 67 65 67 61 50 LwA Inlet 74 60 69 65 67 65 68 62 51
LwA Outlet 71 58 61 58 62 65 65 61 52 LwA Outlet 72 55 65 60 63 65 65 60 48
LwA Surrounding 62 42 57 56 52 52 55 48 33 LwA Surrounding 62 41 57 55 51 52 55 48 33
Measurement point: 0.772 m³/s @ 211 Pa Measurement point: 0.766 m³/s @ 241 Pa
300 | Smoke Extract Fans

MUB 062 560D4/F MUB 062 560D4/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
extract fans

LwA Inlet 85 71 80 79 76 74 74 74 68 LwA Inlet 85 75 81 78 76 74 75 75 69


LwA Outlet 82 72 74 72 75 75 74 73 67 LwA Outlet 86 65 84 75 76 76 75 74 67
Smoke

LwA Surrounding 76 52 74 68 64 62 61 58 49 LwA Surrounding 76 55 74 68 64 63 62 59 50


Measurement point: 1.47 m³/s @ 586 Pa Measurement point: 1.46 m³/s @ 681 Pa

MUB 062 560D6/F MUB 062 560D6/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 61 70 68 65 65 66 65 55 LwA Inlet 76 63 71 67 66 66 67 64 56
LwA Outlet 81 68 73 73 76 73 70 65 58 LwA Outlet 73 56 64 65 65 66 65 63 54
LwA Surrounding 65 44 59 59 55 55 56 55 40 LwA Surrounding 65 46 60 59 55 56 57 54 40
Measurement point: 0.983 m³/s @ 259 Pa Measurement point: 0.972 m³/s @ 305 Pa
Smoke Extract Fans | 301

MUB 062 630D4/F MUB 062 630D4/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

extract fans
Smoke
LwA Inlet 93 79 85 87 87 85 84 79 72 LwA Inlet 92 74 83 85 86 85 83 79 72
LwA Outlet 93 82 84 84 87 87 84 80 74 LwA Outlet 94 85 83 87 87 87 85 80 74
LwA Surrounding 83 62 74 81 70 70 72 67 56 LwA Surrounding 82 58 72 80 69 69 71 66 56
Measurement point: 1.42 m³/s @ 759 Pa Measurement point: 1.91 m³/s @ 800 Pa

MUB 062 630D6/F MUB 062 630D6/F

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 67 76 75 76 74 72 67 64 LwA Inlet 82 65 76 75 76 74 72 67 64
LwA Outlet 80 62 68 71 74 75 71 66 60 LwA Outlet 81 68 74 72 75 75 72 67 62
LwA Surrounding 71 48 68 64 61 60 61 55 46 LwA Surrounding 71 46 67 64 60 60 61 55 45
Measurement point: 1.09 m³/s @ 253 Pa Measurement point: 1.26 m³/s @ 353 Pa
302 | Smoke Extract Fans

AXC (B) / AXR (B) Electrical


accessories
• AXC with aerofoil impeller, adjustable pitch angle for max. efficiency
• Die cast aluminium hub and blades
• Long casing, hot dip galvanized steel, to DIN EN ISO 1461; AXC-E
versions in pre-galvanized steel AES p. 383
• Spun flanges for high rigidity, to Eurovent 1/2
• Terminal box in IP65 mounted at the outside of the casing for easy
wiring; AXC-E versions without external terminal box
• Motors IP54/55, insulation class H, in accordance with EN 60034-5/ FRQ p. 361

IEC 85
• Suitable for operating temperatures of up to -20/55°C continuous
or once for 300°C/120 min.
• Inspection hole to verify correct direction of rotation
IE2
2009/640/EG
• Truly reversible version AXR (B) on request
300°C 120min • IE2 motors on request

AXC (B), AXR (B) Smoke extract axial fans certified for
300°C/120 min. in accordance with EN 12101-3

The Systemair AXC (B)/AXR (B) range of High efficiency impellers Multi stage fans
long cased smoke extract axial fans is The AXC die cast aerofoil aluminium im- For higher pressure drops two stage fans
available in sizes from 315 up to 1.600
extract fans

pellers can be offered with full or frac- are offered. Two fans in series increase
mm nominal diameter. The adjustable tional solidities, maximum efficiencies the available static operational pressure.
Smoke

pitch angle setting offers a wide perfor- can be obtained. AXR impellers are truly
mance and maximum flexibility to match reversible. Quality
precisely individual airflow requirements.
The AXC (B) and AXR (B) axial fans have Systemair is certified according to ISO
Sturdy casing 9001:2008 and ISO 14001:2004. The
been performance tested in accordance
with DIN ISO 5801, DIN 24163 and AMCA AXC and AXR axial fan casings are heavy Systemair quality system is regularly
210-99 on the Systemair fan test rig. gauge, hot dip galvanized, with spun monitored by TÜV Süd.
High temperature testing in accordance flanges for high rigidity. Long cased ex-
with EN 12101-3. All AXC (B) fans are la- ecution as standard stock range. AXC-E
beled with the CE-mark. series with pre-galvanized casing.

Motors
Motor in the air stream. Motors for fre-
quency control on request. Single or two
speed motors.

Ordering code

AXR
Axial fan, reversible

AXC 630 - 9 / 22° - 2 (B)

300°/120 min.

2-pole motor

Pitch angle

Number of blades

Nominal diameter

Axial fan unidirectional


Smoke Extract Fans | 303

Selection program for axial fans AXC Ventilation


accessories
You can find the Systemair selection program for
axial fans on our website www.systemair.com.

The product selector covers all medium pressure


ESD-F p. 438
axial fans for standard temperature and smoke ex-
traction of the types AXC, AXC(B) and AXC(F). Further
advantage: the new version of the Systemair product
selector needs no installation because the selector
works online. EV-AR/AXC
p. 436

FSD-AXC
p. 433

GFL-AR/AXC
Selection program AXC p. 437
The Systemair product selector for axial fans is available
in two versions: The always updated online version

extract fans
Smoke
(recommended) or the offline version, integrated in
our product selector SSP3. Both are available from LRK p. 430
www.systemair.com.

MFA-AR/AXC
p. 432

RSA p. 430

MP-AXC
p. 432

SG-AR/AXC
p. 431

ZSD p. 433

MPR p. 431
304 | Smoke Extract Fans

AXC (F) / AXR (F) Electrical


accessories
• AXC with aerofoil impeller, adjustable pitch angle
• Die cast aluminium hub and blades
• Long casing, hot dip galvanized steel, to DIN EN ISO 1461
• Spun flanges for high rigidity, to Eurovent 1/2 AES p. 383
• Terminal box in IP65 mounted at the outside of the casing for
easy wiring
• Motors IP55 insulation class H, in accordance with EN 60034-5/
IEC 85 FRQ p. 361

• Suitable for operating temperatures of up to -20/55°C continu-


ous or once for 400°C/120 min.
• Inspection hole to verify correct direction of rotation
• Truly reversible version AXR (F) on request

400°C 120min
AXC (F), AXR (F) Smoke extract axial fans certified for
400°C/120 min. in accordance with EN 12101-3

The Systemair AXC (F)/AXR (F) range of High efficiency impellers Multi stage fans
long cased smoke extract axial fans is The AXC aerofoil aluminium impellers For higher pressure drops two stage fans
available in sizes from 315 up to 1.600 can be offered with full or fractional are offered. Two fans in series increase
mm nominal diameter. The adjustable solidities, maximum efficiencies can be the available static operational pressure.
extract fans

pitch angle setting at the factory of- obtained.


fers a wide performance and maximum
Smoke

Quality
flexibility to match precisely individual
Sturdy casing Systemair is certified according to ISO
airflow requirements. The AXC (F)/AXR
(F) axial fans have been performance AXC (F)/AXR (F) axial fan casings are 9001:2008 and ISO 14001:2004. The
tested in accordance with DIN ISO 5801, heavy gauge, hot dip galvanized, with Systemair quality system is regularly
DIN 24163 and AMCA 210-99 on the spun flanges for high rigidity. Long cased monitored by TÜV Süd.
Systemair fan test rig. High temperature execution as standard range.
testing in accordance with EN 12010-3.
All AXC (F)/AXR (F) fans are labeled with Motors
the CE-mark. Motor in the air stream. Motors control-
lably by frequency on request. Single or
two speed motors.

Ordering code

AXR
Axial fan reversible

AXC 630 - 9 / 22° - 2 (F)

400°/120 min.

2-pole motor

Pitch angle

Number of blades

Nominal diameter

Axial fan unidirectional


Smoke Extract Fans | 305

Ventilation
accessories

ESD-F p. 438

EV-AR/AXC
p. 436

FSD-AXC
p. 433

GFL-AR/AXC
p. 437

extract fans
Smoke
LRK p. 430

MFA-AR/AXC
p. 432

Exhaust fans

RSA p. 430

MP-AXC
p. 432

SG-AR/AXC
p. 431

ZSD p. 433

MPR p. 431
306 | Smoke Extract Fans

Green Ventilation
The standard for efficient car park ventilation

High safety standard requirements and energy efficiency –

80%
Systemair’s Green Ventilation Jet Fan System fulfills these
demands without compromise: The system achieves 80%
energy saving in Green Ventilation mode* and you can trust
the safety promise of a global system partner.
ing
y sav ion mode
Energ
extract fans

Three times good ntilat


en Ve
in Gre
Smoke

• Low operating cost


• Competitive initial investment
• Complying with European and international standards

All Systemair products and systems, marked with the Green Ventilation label,
meet highest requirements for energy and economic efficiency.

Components Application examples and planning


The Green Ventilation Jet Fan System basically replaces the The better the planning, the more efficient the system.
duct system of a car park. Depending on the ventilation In addition to the car park dimensions, a proper planning
concept of the individual car park and the defined safety includes data such as occupancy, utilization pattern and
standards, supply fans in addition to the exhaust fans may peak loads. The dimensioning of the ventilation system
be installed. generally is based on the air exchange rate (depending
on the atmospheric pollution) or on a defined air volume,
Systemair offers axial supply fans (AXC series) as well as which is multiplied with the amount of parking spaces.
high temperature exhaust fans, axial or centrifugal models,
for in duct or roof installation (AXC (B), AXC (F) or DVV With the use of a Green Ventilation System you can avoid
series), certified in accordance with EN 12101-3. „dead“ zones in the car park. Systemair jet fans are used
for everyday demand ventilation as well as smoke extraction
Systemair is able to offer you all further components, e.g. in case of fire.
silencers, dampers and other ventilation elements for a
modern ventilation system.

*Comparison of CO mode with rated power of car park exhaust fans


Smoke Extract Fans | 307

Exhaust fans Silencer

Advantages and benefits of Systemair Green Ventilation Jet Fan Systems

For investors For operators


• Reduction of investment cost because bulky • Energy saving – The Green Ventilation Jet Fan System

extract fans
Smoke
and complex duct systems can be omitted. A great saves up to 80% energy. This leads to considerably
advantage especially for renovation projects. reduced operating cost. The center-piece is an intelligent
control unit for an energy-efficient, demand controlled
• Modern aesthetics – The flexible positioning of
ventilation. Pressure drops of a duct system do not
the jet fans allow for a modern and aesthetic design.
exist, allowing to downsize the fan energy.
• Attractive and well arranged – The whole design
• Tailored to suit your needs – CO (carbon monoxide)
is more attractive and there are no line-of-sight
sensors activate only those fans which are really
obstructions coming from the ductwork.
needed. Pre-defined areas can be ventilated without
For consultants running the whole system. This, again, helps to lower
• High flexibility – Whether it is a new building or the running costs.
renovation of parking decks, the jet fan positioning is • Good air quality – In comparison to conventional ducted
highly flexible. systems, the concentration of pollutants in the air is
• Time saving design work – No complex duct system is lower when using a jet fan system. The air all over
needed. the activated car park area is constantly in motion,
increasing the clean air ratio in all areas.
• Evidence of functionality – Use the Systemair CFD
analysis and the possibility to carry out smoke tests, • Jet fan systems for heat and smoke extraction avoid
you will always be on the safe side. cost-intensive secondary damages. Ceilings are exposed
to lower temperature, smoke will be quickly removed
For installers
from the building.
• Easy installation work – Jet fans are fast and easy to be
• Optimum safety in case of fire – Fast smoke and heat
installed to the car park ceiling.
extraction prevent the heat and smoke from spreading
• Trouble-free installation – The fans can be installed as into other car park areas. Precise smoke control is
last subsection, means less interfaces with other crafts. facilitating the work of firefighters.
• Flexible fan positioning. • Easy to maintain.
308 | Smoke Extract Fans

Customized solutions
System description

Driveway, ramp or other fresh air openings can supply natural In case of an exhaust air fan failure, it is important that the
fresh air. The supply air is designed to guarantee an almost control detects and indicates this failure automatically and finally
laminar air flow. If no natural supply air can be provided, a sup- switches over to the second fan.
ply air fan is needed.
extract fans

Different versions of axial, radial and roof fans are available,


The Green Ventilation Jet Fan System supports the natural for standard temperature up to temperature class F600
Smoke

air flow between supply and exhaust air and helps accele- (600 °C/120 min.).
rate the airflow in areas where it is too low to guarantee a
sufficient air change all over the car park. According to safety An optimised operation is provided by the project designed
regulations, virtual smoke sectors are created by aerodyna- Green Ventilation control system. It analyses measurements of
mic loads in case of fire. This allows the design of wide and CO exhaust sensors and/or fire/smoke detectors and controls
spacious car parks which normally need to be separated by single, virtual smoke and CO zones according to the requirements.
gates or other in-stallation elements. This always includes Jet fans in not affected smoke and CO zones are controlled
the aspect of efficiency and energy efficiency without losing according to the stored control matrix. The system will be
sight of investment costs. designed in accordance with the requirements given in the
specifications. Complete documentation can be found within the
A project-related switching matrix ensures that legal control cabinet.
requirements are observed and individual safety objectives
are followed.
Exhaust air

These are e.g. maximum CO and smoke gas concentration,


required sight distances for personal rescue and preparation
of fire-fighting operations by fire services.

Exhaust air

Supply air

Virtual smoke zones


Supply air
Smoke Extract Fans | 309

Installed premium jet fan Warning sign

The space required by different ventilation systems has a


direct impact on the investment cost of a project. Jet fans Green Ventilation and smoke extraction function
do only punctually reduce the available ceiling height and
Many systems provide an opportunity either to save
need often unlike many other installation systems like electric energy or to extract smoke out of your car park. But why

extract fans
Smoke
wiring and water pipes less than 0.5% ceiling surface. The should you choose the one or the other?
extra ceiling space can be used for technical appliances and/
Systemair educated smoke extraction car park systems in
or allows to reduce the ceiling height during the planning energy saving.
stage already. Another advantage is a higher safety of an
active system which, depending on the fire location, reacts
in accordance with the defined fire scenario matrix and offers
best possible protection to human beings and buildings .

Systemair remains your partner from the car park‘s planning


to the commissioning and designs Green Ventilation car park
exhaust systems according to your requirements.

Energy cost reduction Reduction


Case study
% Power requirement for a 5000 m² car park, 60.000 m³/h; 13 jet fans

100
kW
80
40
60

40 20

20
0
0 Jet System Jet System Green Ventilation
Jet System Jet System Green Ventilation EFF2 motor IE2 motor mode
EFF2 motor IE2 motor mode
310 | Smoke Extract Fans

Jet Fan AJR-TR Electrical


accessories
• Dual use: For daily ventilation and smoke extraction
in case of fire F300 (300 °C/120 min.)
• S ymmetrical blades; 100% reversible with low sound level
• Motors IP55, insulation class H (smoke extract); Motors IP55,
insulation class F (CO-exhaust), according to EN 60034-5/IEC 85 FRQ p. 361
• 50/60 Hz range available
• Tested inspection switch optional
• Casing manufactured from galvanized steel

IE2
2009/640/EG


Certified to EN 12101-3
CE-certification by BSI AES p. 383

Systemair Jet fans offer highest system performance at low instal-


lation and running costs. Available in three sizes, impeller diameter
315, 355 and 400 mm. The system provides day-by-day ventilation
up to 55°C. FET-AP
For optimized performance the silencers have integrated inlet p. 385
cones. The sound attenuating material is non-inflammable according
to DIN 4102, corresponding with EU guideline 97/69.
As accessory deflectors on the outlet side are available.

FEP-AP
p. 385
extract fans
Smoke

DKM-2K
p. 385

Technical data
55°C 300°C/120 min.
AJR-TR
315-2/4-TR 355-2/4-TR 400-2/4-TR 315-2/4 (B)-TR 355-2/4 (B)-TR 400-2/4 (B)-TR 400-2/4 (B)-TR-L
Art. no. 36277 36278 36279 36221 36222 36400 36175
Voltage/Frequency V/50 Hz 415 3~ 415 3~ 415 3~ 415 3~ 415 3~ 415 3~ 415 3~
Speed 1/min 2825/1360 2840/1380 2840/1380 2880/1440 2880/1440 2880/1440 2880/1440
Rated power kW 0.75/0.17 1.4/0.3 1.5/0.4 0.8/0.16 1.5/0.3 1.5/0.3 1.7/0.34
Rated current A 1.83/0.65 3.33/0.82 3.0/1.07 1.9/0.4 3.0/0.7 3.0/0.7 3.5/0.8
Thrust N 22/6 37/9 55/14 22/6 37/9 55/14 66/17
Air volume m3/s 1.22/0.61 1.78/0.89 2.42/1.21 1.22/0.61 1.78/0.89 2.42/1.21 2.62/1.32
Weight kg 60 66 68 60 66 68 68
Wiring diagram p. 442-461 14b 14b 14b 14b 14b 14b 14b
Air volume related to air density 1.2 kg/m³
Smoke Extract Fans | 311

Dimensions Ventilation
accessories
A
C
This document must not be copied without our written per-
mission, and the contents thereof must not be imparted to
a third party nor be used for any unauthorized purpose.
Contravention will be prosecuted. SYSTEMAIR GmbH

B
D
E

DF-AJ p. 433
H
F

Safety-Anchor
p. 433

Size ⌀H A B C D E F
Bgr. A B C D E F H
315 420 1535 211 433 265 223 425
315 1535 211 433 265 223 425 420
355 460 1695 211 473 355
305
1695 211 473
243305 243 465
465460
400 500 1875 211 516 400 350
1875 211 516266350 266 505 505500
Zuwiderhandlungen werden verfolgt. SYSTEMAIR GmbH
an dritte ist Verboten. Für diese Zeichnung behalten
Das Vervielfältigen dieser Zeichnung und Mitteilen

wir uns alle Rechte gemäß Urheberschutz vor.

9 4 Stahl Verzinkt Q04815001 1.0038;RSt37-2


NIETE_STAHL_STAHL_5MM_4LG mm

8 2 protection guard - 400007 1.0330, DC01-A mm

7 1 Motorstrebe, unten --- AM0400B008 1.0266, DX51D 3.000 mm

6 1 Motor IEC 90L VEM-KR-090 MOTOR_BG_090L_B3 -;- mm

5 1 Laufrad kpl. / impeller comp. ------ AXC_400-10 - mm

4 2 Fuß JF 400 - AM0400F015 1.0226, DX51D+Z275MA-C 2.500 mm

3 1 - KLEMMKASTENZSB mm

2 2 - - JF400021 1.0330, DC01-A mm

1 1 - - AM400210-00 1.0330, DC01-A mm

Pos.:/ Menge:/ Benennung:/ Artikelnr.:/ Zeichnungsnr.:/ Werkstoff:/ Blechdicke:/


pos.: quantity: title: item no.: drawing no.: material: thickness:
Datum/date Name/name Systemair Artikelnr.:/ Maßstab:/
scale: 13:100 Gewicht:/
weight: 917.22 kg
gezeichnet:/
drawn by: 06.02.2013 T.Leutwein Systemair item no.:
geprüft:/
checked by: - - Oberfl.Qualität:/ Baugröße:/

extract fans
Smoke
surface quality: size:
Werkstoff: siehe Stückliste
material: see bill of material Lieferant Art.Nr.:/
supplier item no.:
Dicke: siehe Stückliste
thickness: see bill of material
Maße ohne Toleranz- Benennung:/title:
angabe nach:
Zeichnungsnummer:/drawing no.:
Übersicht AJR-E (TR)
measurements without
Nr.: tolerances according:
no.: Datum/date: Name/name:

Änderungsindex / revision index: DIN 6930-m AM-UEBERSICHT-AJR-E

Reference: Dubai Mall, Dubai, UAE


312 | Smoke Extract Fans

Jet Fan AJ8 - Premium Version Electrical


accessories
• Dual use: For daily ventilation and smoke extraction in case of
fire F300 (300 °C/120 min.)
• Aerodynamical impellers for maximum thrust and with low
sound level
• Motors IP55, insulation class H (smoke extract); Motors IP55, FRQ p. 361
insulation class F (CO-exhaust), according to EN 60034-5/
IEC 85
• Tested inspection switch optional

IE2
2009/640/EG


Compact design, reduced height
Casing manufactured from galvanized steel AES p. 383
• Certified to EN 12101-3
• CE-certification by BSI

Systemair Jet fans AJ8 offer highest system performance at low


installation and running costs. Available in three sizes, impeller FET-AP
diameter 315, 355 and 400 mm. The system provides day-by- p. 385
day ventilation as well as smoke extraction.
For optimized performance the silencers have integrated inlet
cones. The sound attenuating material is non-inflammable
according to DIN 4102, corresponding with EU guideline 97/69.
As accessory deflectors on the outlet side are available. FEP-AP
p. 385
extract fans
Smoke

DKM-2K
p. 385

Technical data
55°C 300 °C/120 min.
AJ8
315-2/4 355-2/4 400-2/4 315-2/4 (B) 355-2/4 (B) 400-2/4 (B)
Art. no. 32768 32769 32770 32771 32772 32773
Voltage/Frequency V/50 Hz 415 3~ 415 3~ 415 3~ 415 3~ 415 3~ 415 3~
Speed 1/min 2825/1360 2840/1380 2840/1380 2880/1450 2905/1460 2880/1445
Rated power kW 0.75/0.17 1.4/0.3 1.5/0.4 0.75/0.15 1.3/0.25 1.5/0.37
Rated current A 1.83/0.65 3.33/0.82 3.0/1.07 1.6/0.4 3.1/0.68 3.9/0.95
Thrust N 23/6 37/9 55/11 23/6 37/9 55/11
Air volume m3/s 1.22/0.61 1.75/0.88 2.42/1.21 1.22/0.61 1.75/0.88 2.42/1.21
Weight kg 84 90 99 84 90 99
Wiring diagram p. 442-461 14b 14b 14b 14b 14b 14b
Air volume related to air density 1.2 kg/m³
Smoke Extract Fans | 313

Dimensions Ventilation
accessories
F
E
C
K

DF-AJ8 p. 433

H
L
B Safety-Anchor
p. 433
Lt

Size H B C E F K L Lt ts tc tm
315 365 550 355 610 650 476 2200 2213 1.0 2.0 2.5
355 395 550 355 610 650 476 2200 2213 1.0 2.0 2.5
400 445 600 380 660 700 476 2200 2213 1.0 2.0 2.5

extract fans
Smoke

Reference: St.-Josef-Hospital, Bochum


314 | Smoke Extract Fans

IV (B)
• Dual use: For daily ventilation and smoke extraction in case of fire F300
(300°C/120 min.); F400 (400°/120 min.) on request
• Aerodynamical centrifugal impeller for maximum thrust and with low sound level
• Motors IP55, insulation class H (smoke extract)
• Tested inspection switch optional
• Compact design for low ceiling heights
• Casing manufactured from galvanized steel
300°C 120min 400°C 120min • Integrated deflector
• Certified to EN 12101-3
• CE-certification by BSI

Technical data
300°C/120 min.
IV
50-4 (B) 50-4/6 (B) 50-4/8 (B) 85-4 (B) 85-4/6 (B) 85-4/8 (B)
Art. no. 33477 33529 33530 33478 33534 33535
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection Y YY/Y YY/Y Y YY/Y YY/Y
extract fans

Speed 1/min 1435 1445/955 1430/715 1435 1450/965 1425/715


Rated power kW 1.5 1.5/0.55 1.3/0.22 2.2 2.2/0.75 2.2/0.37
Smoke

Rated current A 3.4 3.7/1.9 3.2/1.15 4.7 4.9/2.6 6.7/2.2


Thrust N 52 52/20 52/14 85 85/28 85/22
Air volume m³/s 1.72 1.72/1.16 1.71/0.86 2.76 2.76/1.63 2.76/1.42
Weight kg 120 120 120 170 175 170

Dimensions
E
6x ⌀K
A
B
C

I H

Size A B C D E F H I 6xøK
IV 50 790 834 870 1248 285 370 185 210 13.5
IV 85 1140 1184 1220 1900 340 420 210 430 13.5
Smoke Extract Fans | 315

Our control at your service!


Systemair control systems

extract fans
Smoke
Every building has individual requirements for ventilation and The Systemair control system
smoke extraction concepts. Safety and efficiency are not in con- The Systemair control system provides active motor protection
tradiction. during normal ventilation mode with single and group error
messages (only for standard temperature version).
In case of a fire, the control disregards energy consumption. It is
important to guarantee the safety of the people and the building, The control system includes fan control for ventilation and
to enable the personal rescue and assist the fire brigade and smoke extraction of underground car parks, equipped with
other action forces in their work, which minimizes fire and smoke supply and exhaust fans, jet fans and sensors.
gas damages.
Single- or double-speed fans and unidirectional or reversible
However, the systems generally run 24 hours a day and 365 fans can be controlled. Each jet fan can be separately switched
days a year. Therefore each kilowatt of electrical energy used by on or off for maintenance and commissioning.
the system counts for the operator or owner of the building.
In normal ventilation mode, the control system works either in
Compared to conventional systems a Green Ventilation Car Park accordance with the CO alarm system, or the timer, or the BMS
System considerably reduces the energy use. system data. The fan will run either in high or low speed in the
selected flow direction.
For an optimal function, the control system has to be designed
individually to meet all requirements of the project. Ideally, this In case of fire, the control system acts dependent on the fire
must be done in line with all other crafts during basic conception alarm system. Virtual fire zones with different flow directions
and coordinated with the ventilation system of the building. Air can be formed for smoke extraction. Fans being activated in
quality requirements for desk spaces are different from those for the fire zone operate automatically in the selected speed and
underground car parks. Because of the duration of stay and other airflow direction. The built-in motor overload protection will be
factors, harmful substances influence the human health. The fac- deactivated in the control cabinet. The fan permanently runs
tor time/duration of stay in the car park is responsible for diffe- for a minimum period of 2 hours in the chosen temperature
rent legal demands to average time values concerning CO/NO₂/ range, until mechanically demolished by the fire.
LPG exposure (half-hourly average value, quarter-hourly average
value, …). Therefore, you can specify some areas of your building
with different air quality that allows to provide exhaust air from
the air conditioning unit to other areas as supply air.

Normally, the windows of energy optimised, modern buildings


are not permanently in a tilted position. In fact, air quality in mo-
dern buildings is monitored and can be changed when preset
maximum values are achieved. Systemair implements this con-
cept also for underground car parks. On demand, the parameters
can be changed and customised by the user. All legal require-
ments can be accomplished.
316 | Smoke Extract Fans

Safety requires individual planning


CFD simulation

CFD simulation is needed to confirm that there is enough


air movement in all areas of the car park to secure the
required number of air exchanges, to confirm the pro-
posed number of jet fans and to determine the location
where the jet fans have to be installed.
extract fans

In order to be able to perform a CFD analysis, it is es-


sential to have a 3D model of the building site, giving all
Smoke

openings, slab height, surface of the ceiling (flat or with


drop beams, dimensioning of the drop beams, etc.) and
all other details required to carry out a simulation.

A CFD analysis is used to simulate the airflows, to ensure Velocity vectors (without Jet fans) 2,35 m above the ground
that the distribution of the air is sufficient to effectively
ventilate the cark park under normal conditions as well velocity m/s
as in emergency situations. Systemair offers this service
meaning everything from one source and firsthand –
truly tailored solutions.

Smoke concentration (CO2) at 1,5 m height

Smoke concentration in different


rooms on the same floor
Smoke Extract Fans | 317

Systemair as a system partner

Project handling
Electrical planning, commissioning, final approval test,
handing over. Everyone knows the problems on the building
site when ventilation crafts and electrical crafts meet with
different requirements. Two crafts with different requirements

extract fans
Smoke
for your team. Systemair helps you to handle the project
successfully and on schedule. From the conception of the
complete system with CFD analysis to the detailed technical
planning of the ventilation system and the creation of cable
lists, the delivery of components to the points of commissio-
ning and supervised final approval test including warm smoke
gas test. Thus, all planning phases and crafts are in our focus,
we coordinate the interfaces and give you support according
to your needs. Installed supply cable for Jets and main fans

Commissioning
Systemair offers a smoke gas extraction test while commissioning
your car park system. This simulates a case of emergency.

Smoke gas test preparation Smoke gas test during commissioning


318 | Smoke Extract Fans

WVA / WVI
• Smoke extract unit for wall mounting
• 400°C/120 min. (type F400) resp. 600°C/120 min. (type F600)
• Wide range of accessories
• Tested acc. to EN 12101-3
• CE-certified acc. to EN 12101-3, 2002-06

The WVI smoke extract fans are used in case of fire to extract smoke
gases from rooms, and also for daily ventilation (dual purpose fans).
Smoke-free escape ways increase the chances to rescue people in case
of fire.
The casing is manufactured from steel, powder coated RAL 7032. The
base frame consists of galvanized steel. The impeller with backward
curved blades is manufactured from galvanized steel resp. stainless steel
(type F600).
Thermal motor protection on request (PTC or thermal contact). In case
400°C 120min 600°C 120min
of fire all triggering devices must be bridged to guarantee functionality.

WVA WVI Note:


For installation only outside the building. With insulated motor for installation Article numbers in tables refer to items
Fans are certified for horizontal instal- inside the building and inside the fire without PTC or thermal contact.
lation on a wall, motor pointing down- zone. Cooling of motor via air duct IE2 single speed motors are available
wards. (accessories). Fans are certified for with PTC built-in. Data related to motor
extract fans

horizontal installation on an outer wall, and weight of delivered items can vary
Smoke

motor facing downwards. from catalogue data.

Quick selection (WVA/WVI 630-1000)

1 WVA/WVI 630D4-K 4 WVA/WVI 630D4


1 WVA/WVI 800D6
2 WVA/WVI 630D6-K 5 WVA/WVI 630D6
2 WVA/WVI 800D8
3 WVA/WVI 630D8-K 6 WVA/WVI 800D6-K
3 WVA/WVI 800D12
7 WVA/WVI 800D8-K
4 WVA/WVI 1000D6
8 WVA/WVI 800D12-K
5 WVA/WVI 1000D8
6 WVA/WVI 1000D12
1 4

5 1 4

2
2

6
3
5 7 6
8 3

Technical data available online on www.systemair.com.


WVA/WVI 400D4 400D4-6 400D4-8 450D4 450D4-6 450D4-8 560D4 560D4-6 560D4-8 630D4-K 630D4-6-K 630D4-8-K
Art. no. WVA F400 30736 30737 95099 30739 30740 95101 30742 30743 95103 30750 30751 30752
Art. no. WVA F600 30789 30790 95100 30792 30793 95102 30795 30796 95104 30802 30803 30804
Art. no. WVI F400 30763 30764 95105 30766 30767 95107 30769 30770 95109 30776 30777 30778
Art. no. WVI F600 30815 30816 95106 30818 30819 95108 30821 30882 95110 30828 30829 30830

WVA/WVI 630D4 630D4-6 800D6-K 800D6-8-K 800D6-12-K 800D6 800D6-12 1000D6 1000D6-8 1000D6-12
Art. no. WVA F400 30746 30747 30757 30758 30759 30754 30756 30760 30761 30762
Art. no. WVA F600 30798 30799 30809 30810 30811 30806 30808 30812 30813 30814
Art. no. WVI F400 30772 30773 30783 30784 30785 30780 30782 30786 30787 30788
Art. no. WVI F600 30824 30825 30835 30836 30837 30832 30834 30838 30839 30840
Smoke Extract Fans | 319

Dimensions Ventilation
accessories
A A
M8 M8

D D
EPSN/EPIN
C

B
E
E

max. F

R
IN

F
S
G øP

G SN

øM
WBK-W
I
øM
H

I
H

øM
ZHZ
L

L
J
K J

extract fans
Smoke
K
More detailed dimensions on www.systemair.com

WVA/WVI A B C D E F £G £H I J K L øM øP R £S Inlet duct


connection ø
400 536 286 250 500 33 250 500 536 670 472 790 290 356 (8xM8) 510 116 200 315
450 746 286 250 710 33 300 500 536 764 528 886 340 395 (8xM8) 638 240 200 355
560 746 316 280 710 33 350 630 666 855 590 991 380 438 (12xM8) 638 200 225 400
630 836 391 355 800 33 450 710 746 1055 730 1237 465 541 (12xM8) 808 349 225 500
800 1156 436 400 1120 43 450 900 936 1300 930 1545 560 674 (16xM10) 980 295 250 630
1000 1446 666 630 1400 43 600 1180 1216 1400 1010 1700 580 751 (16xM10) 980 442 250 710

Installation examples

Flexible connection EPSN


Outer wall
Outer wall

Air direction
Inlet duct SN
Environment
Inlet duct SN Environment
Outlet duct IN

Air direction Fire zone


WVI
Fire zone Air direction
WVA
Cooling duct
ZHZ Outlet duct IN

Cooling air
Cooling air Supports WBK-W

Supports WBK-W
320 | Fans for Aggressive Media

Fans for Aggressive Media


IE2
2009/640/EG

6
For aggressive

2
media

General
Plastic fans for aggressive media Single inlet centrifugal fan PRF
These sturdy plastic fans have been Casing Impellers
developed especially for applications where Standard casing in PE, water tight, with Single inlet impellers manufactured from PP.
dirt or aggressive gases can contaminate connections from 125 to 250 mm dia–
the exhaust air. Typical applications are meter. Can be turned to have other outlet Motors
laboratories in medical or pharmaceutical directions. Standard position LG270 (as per IEC standard motors, separated from the
institutions, food industry and chemical illustration). airstream, in ISO F, equipped with PTC cold
industry. conductors or with thermal contacts, to be
Motor pedestal connected to a PTC/TK triggering device.
Manufactured from steel, powder coated.
Fans for Aggressive Media | 321

1 VKA-P Adjustable damper

2 ASS-P Flexible connection


3 SD Anti vibration mounts

4 PRF Centrifugal fan


5 VP Splinter protection

6 VKS-P Automatic shutter

media
For aggressive
PRF IE2
322
Roof fan DVP 2009/640/EG

Casing Plastic fan


Vertical outlet casing and single inlet
backward curved impeller manufactured
from PP.

Motors DVP 328


Motor speed controllable by frequency
inverter. Connections from 200 to 400 mm Plastic roof fan
diameter.
322 | Fans for Aggressive Media

PRF Electrical
accessories
• T emperature of transported air from -15°C to +70°C
• Single-flow impellers from PP with effective blade geometry
• The powder painted pedestal is manufactured from galvanised
steel
• P osition of casing can be easily adapted REU p. 356
• Perfect fitting accessories: connections, dampers, splinter
protection

The PRF fans have been developed especially for the exhaust of
aggressive media. This is the right fan when corrosive gases,
contaminated air or other aggressive components are part of the RTRE p. 356
exhaust air. Typical applications are medical facilities, the food-,
electrical- or chemical industry.

IE2
2009/640/EG
The sintered casing from UV-resistant PE offers a variety of
applications with its connectors from ø 125 - 250 mm. The
casing can be easily adjusted through turning it (standard position
REV p. 380
is LG270, see picture).

Quick selection

3.000
PRF 180E4
1 PRF 125D2
1
2 PRF 200D2
S-ET p. 373
2 PFR 160D2 3 PRF 200DV
2.500 4 PRF 250D2
3 PRF 160D4
5 PRF 250D4
4 PRF 160E4 6 PRF 250D2-L
5 PRF 180D2
2.000
6 PRF 180DV
For aggressive

1.500 STDT p. 373


1 2 5
6
media

1.000

500
3
5 2 4 FRQ p. 361
4
3 1

0
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2,0 2,2

Technical data
PRF 125D2 160D2 IE2 160D4 160E4 180D2 IE2 180DV
Art. no. 31525 33562 31495 31545 33563 31497
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 230 1~ 400 3~ 400 3~
Connection - Y - - Y -
Power W 250 919 142 171 1396 229
Current A 0.579 1.68 0.571 0.75 2.37 1.01
Starting current - 8.9 - - 16.5 -
Max. air flow m3/s 0.197 0.46 0.228 0.213 0.63 0.32
R.p.m. min-1 2806 2825 1467 1427 2825 1365
Max. temp. of transported air °C 70 70 70 70 70 70
“ when speed controlled °C 70 - – – - 70
Sound pressure level at 3 m dB(A) 59 66 49.6 45.7 68 49
Weight kg 15 21.5 14.5 13 24 15
Insulation class, motor F F F F F F
Enclosure class, motor IP 55 IP 55 IP 54 IP 54 IP 55 IP 54
Capacitor µF – – – 6 – –
Motor protection – – – S-ET 10 – STDT 16
Speed control, five-step Transformer – FRQ5(S)-4A – RTRE 1.5 FRQ5(S)-4A RTRD 2
Speed control, five-step high/low Transformer – – – REU 1.5 – RTRDU 2
Speed control, stepless – FRQ(S)-4A – – FRQ(S)-4A –
Wiring diagram p. 442-461 17a 17a 17a 21 17a 17c
Fans for Aggressive Media | 323

Dimensions Ventilation
C accessories
E
L

ASS-P p. 440
D

A SD-PRF p. 439
H

R N
VKA-P p. 440
P D
Q

PRF A C øD E H L N P Q R
125D2 140 40 125 150 250 195 200 100 140 235
160D2 183 40 160 180 310 210 255 100 140 290
VKS-P p. 440
160D4/E4 183 40 160 180 310 190 255 100 140 290
180D2 208 40 180 190 350 230 277 120 190 320
180E4/DV 208 40 180 190 350 190 277 120 190 320
200D2 240 40 200 200 410 245 320 150 230 355
200DV 240 40 200 200 410 210 320 150 230 355 VP p. 439
250D2 290 40 250 240 495 340 330 170 250 370
250D2-L 290 40 250 240 495 330 170 250 370
250D4 290 40 250 240 495 230 330 170 250 370

WSD PRF
p. 440

media
For aggressive
PRF 180E4 200D2 IE2 200DV 250D2 IE2 250D2-L IE2 250D4 IE2
Art. no. 31564 33564 31499 33566 34531 33565
Voltage/Frequency V/50 Hz 230 1~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Connection - Y - D - Y
Power W 140 2101 250 5396 5500 995
Current A 1.11 3.16 0.95 7.64 10.4 1.78
Starting current A - 22.4 - 57.3 8.9
Max. air flow m3/s 0.32 0.861 0.47 1.11 1.67 0.91
R.p.m. min-1 1365 2840 1413 2890 2852 1390
Min. back pressure Pa - 400 - 2000 600 -
Max. temp. of transported air °C 70 70 70 70 70 70
“ when speed controlled °C 70 - 70 - 70 -
Sound pressure level at 3 m dB(A) 49 73 59.5 85 85 65
Weight kg 15 29 21 55 50 55
Insulation class, motor F F F F F F
Enclosure class, motor IP 54 IP 55 IP 54 IP 55 IP 54 IP 55
Capacitor µF 6 – – – – –
Motor protection S-ET 10 – STDT 16 – – –
Speed control, five step Transformer RTRE 1.5 – RTRD 2 – – –
Speed control, five step high/low Transformer REU 1.5 – RTRDU 2 – – –
Wiring diagram p. 442-461 21 17a 17c 17b 17b 17a
324 | Fans for Aggressive Media

Performance

PRF 125D2
PRF 160D2 IE2

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 69 61 74 70 68 62 55 48 LwA Inlet 81 70 72 75 75 74 67 59 52
LwA Outlet 80 71 68 77 74 69 62 58 48 LwA Outlet 96 72 76 82 81 77 73 67 59
LwA Surrounding 66 48 25 52 59 64 55 48 39 LwA Surrounding 73 52 44 67 69 66 62 52 44
Measurement point: 0.0725 m³/s @ 589 Pa Measurement point: 0.21 m³/s @ 877 Pa
For aggressive
media

PRF 160D4 PRF 160E4

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 67 57 59 63 59 53 51 42 33 LwA Inlet 67 63 62 58 57 53 49 41 33
LwA Outlet 70 58 64 66 62 55 51 43 34 LwA Outlet 67 55 59 64 62 56 51 43 34
LwA Surrounding 57 17 25 53 52 44 48 38 29 LwA Surrounding 53 32 40 43 48 47 45 35 31
Measurement point: 0.118 m³/s @ 196 Pa Measurement point: 0.104 m³/s @ 195 Pa
Fans for Aggressive Media | 325

PRF 180D2 IE2 PRF 180DV

Minimum back pressure 180 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

LwA Inlet 86 77 80 79 80 79 72 66 60 LwA Inlet 70 53 67 62 62 58 54 48 41


LwA Outlet 90 69 85 84 84 82 77 70 62 LwA Outlet 73 54 70 67 66 60 58 49 41
LwA Surrounding 73 67 45 59 68 68 61 52 46 LwA Surrounding 56 32 34 45 54 49 46 37 34
Measurement point: 0.27 m³/s @ 1093 Pa Measurement point: 0.17 m³/s @ 221 Pa

media
For aggressive
PRF 180E4 PRF 200D2 IE2

Minimum back pressure 400 Pa


dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 69 52 66 61 61 58 54 47 41 LwA Inlet 89 82 77 80 84 83 80 73 66
LwA Outlet 73 53 70 66 66 60 58 49 41 LwA Outlet 92 84 85 84 86 84 82 73 64
LwA Surrounding 56 32 34 45 54 49 46 37 34 LwA Surrounding 80 76 46 62 73 74 71 62 54
Measurement point: 0.17 m³/s @ 221 Pa Measurement point: 0.35 m³/s @ 1576 Pa
326 | Fans for Aggressive Media

PRF 200DV PRF 250D2 IE2

Minimum back pressure 2000 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 59 66 70 72 70 65 58 51 LwA Inlet 101 90 91 95 95 92 91 86 77
LwA Outlet 74 58 69 69 68 63 61 51 42 LwA Outlet 101 85 95 95 95 93 92 84 74
LwA Surrounding 67 32 38 54 65 58 54 48 43 LwA Surrounding 94 68 81 89 88 87 85 82 72
Measurement point: 0.383 m³/s @ 171 Pa Measurement point: 0.82 m³/s @ 2002 Pa
For aggressive
media

0 2.000 4.000 6.000 8.000

3.000 PRF 250D2-L IE2


PRF 250D4 IE2

2.500

2.000

1.500

1.000

500

0
0 0,27 0,55 0,83 1,11 1,39 1,66 1,94 2,22

Minimum back pressure 550 Pa

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 75 74 71 76 75 72 64 55
LwA Inlet 101 90 91 95 95 92 91 86 77
LwA Outlet 86 82 77 76 76 76 75 63 54
LwA Outlet 101 85 95 95 95 93 92 84 74
LwA Surrounding 72 46 50 59 65 70 64 57 43
LwA Surrounding 94 68 81 89 88 87 85 82 72
Measurement point: 0.41 m³/s @ 548 Pa
Measurement point: 0.82 m³/s @ 2002 Pa
Fans for Aggressive Media | 327

media
For aggressive
328 | Fans for Aggressive Media

DVP Electrical
accessories
• Temperature of transported air from -15°C to +60°C
• Single inlet impellers from PP with effective blade geometry
• Weather-resistant, sturdy casing made from PP
• Motor and terminal box in IP55 STDT p. 373
• Motor outside the airstream

The DVP fans have been developed especially for the exhaust
of aggressive media. This is the right fan when corrosive gases,
contaminated air or other aggressive components are part of the S-DT2 SKT
exhaust air. Typical applications are medical facilities, the food, p. 381
electrical or chemical industry. The casing from PP offers a
variety of applications with its connectors from ø200-400 mm.
The motor is speed controllable via frequency converter.
Thermal motor protection and splinter protection on request.
FRQ p. 361

Quick selection

7981, 7979, 7975, 7973


7964, 7955, 7967, 7965, 7969, 7971

1 DVP 200D 2-pole 1 DVP 400D 4-pole


2 DVP 200D 4-pole 2 DVP 400D 8-pole
3 DVP 250D 2-pole 3 DVP 400D-L 4-pole
For aggressive

4 DVP 250D 4-pole 4 DVP 400D-L 8-pole


5 DVP 315D 4-pole
6 DVP 315D 8-pole
media

2 4 1 3
2 4 1 5 3
6

Technical data
DVP 200D2-4 250D2-4 315D4-8 400D4-8 400D4-8-L
Art. no. 32295 32296 32297 32299 32298
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Power W 1714 / 224 5321 / 679 2200 / 441 2019 / 449 4082 / 715
Current A 2.88 / 0.554 8.56 / 1.43 3.27 / 1.73 4.12 / 1.79 7.65 / 2.98
Max. air flow m3/s 0.628 / 0.316 1.27 / 0.649 1.28 / 0.647 1.31 / 0.661 2.11 / 1.05
R.p.m. min-1 2885/1468 2874 / 1468 1494 / 732 1445 / 731 1447 / 733
Max. temp. of transported air °C 60 60 60 60 60
Sound pressure level at 4 m/10 m dB(A) 61/53 / 42/34 69/61 / 51/43 54/46 / 39/31 59/51 / 43/35 60/52 / 46/38
Weight kg 25 35 45 55 55
Insulation class, motor F F F F F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55
Wiring diagram p. 442-461 14a 14a 14a 14a 14a
Fans for Aggressive Media | 329

Dimensions Ventilation
accessories
øF

VKS-DVP
p. 439
H

B
A
ASF-DVP
p. 439
øM
øD
K

DVP 200 = SSD/FDS 310/311


L

DVP 250 = SSD/FDS 355/400 ASS-DVP


DVP 315 = SSD/FDS 450/500 p. 439
øC
DVP 400 = SSD/FDS 560/630
øE

£A £B øC øD øE øF G H K L øM
DVP 200 435 330 200 355 662 200 119 1065 146 30 4x10 SSD p. 419
DVP 250 595 450 250 400 768 250 119 981 181 30 4x12
DVP 315 665 535 315 560 810 315 218 1161 200 30 4x12
DVP 400 939 750 400 601 976 400 218 1134 235 30 4x14
FDS p. 420

media
For aggressive
Performance
Q [m³/h] Q [m³/h]
0 400 800 1200 1600 2000 2400 0 200 400 600 800 1000
1200 300
7955/7956

7963/7964

DVP 200D2-4 2 pole DVP 200D2-4 4 pole


250
900

90 200 74
Ps [Pa]

Ps [Pa]

600 150
89 73

100
300

50

0
0 0.2 0.4 0.6 0
0 0.1 0.2 0.3
Q [m³/s]
Q [m³/s]
2000
400
P [W]

P [W]

1000
200

0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 90 71 74 83 86 83 78 69 61 LwA Inlet 73 57 64 69 65 64 58 48 39
LwA Outlet 85 61 65 78 81 77 76 69 62 LwA Outlet 66 46 54 61 61 57 55 48 39
Measurement point: 0.36 m³/s @ 755 Pa Measurement point: 0.18 m³/s @ 190 Pa
330 | Fans for Aggressive Media

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 5000 0 400 800 1200 1600 2000 2400
1800 500

7965/7966
7967/7968
1600 DVP 250D2-4 2 pole DVP 250D2-4 4 pole
400
1400
100
1200 84
300

Ps [Pa]
Ps [Pa]

1000

800
99 200
83
600

400 100

200

0 0
0 0.4 0.8 1.2 0 0.2 0.4 0.6
Q [m³/s] Q [m³/s]

6000 1000

P [W]
P [W]

3000

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 98 78 81 93 94 89 84 76 69 LwA Inlet 80 60 73 77 73 71 63 56 48
LwA Outlet 95 83 80 86 91 87 85 78 71 LwA Outlet 78 69 68 72 73 70 63 56 49
Measurement point: 0.543 m³/s @ 1218 Pa Measurement point: 0.279 m³/s @ 312 Pa
For aggressive
media

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 5000 0 400 800 1200 1600 2000 2400
200
7969/7970

7971/7972
600 DVP 315D4-8 4 pole
DVP 315D4-8 8 pole
87 150

400
Ps [Pa]

Ps [Pa]

100
75
94

200
50 76

0 0
0 0.4 0.8 1.2 0 0.2 0.4 0.6
Q [m³/s] Q [m³/s]
2500 600
2000
P [W]
P [W]

1500
400
1000
500
0 200

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 66 77 77 74 74 67 64 55 LwA Inlet 68 55 65 61 61 56 47 43 33
LwA Outlet 81 70 75 73 74 73 68 64 57 LwA Outlet 63 45 52 53 61 54 49 45 37
Measurement point: 0.329 m³/s @ 507 Pa Measurement point: 0.335 m³/s @ 83.7 Pa
Fans for Aggressive Media | 331

Q [m³/h] Q [m³/h]
0 1000 2000 3000 4000 5000 0 400 800 1200 1600 2000 2400
800 200

7981/7982

7979/7980
DVP 400D4-8 4 pole DVP 400D4-8 8 pole

600 150

96
Ps [Pa]

Ps [Pa]
83
400 100

91
75
200 50

0 0
0 0.4 0.8 1.2 0 0.2 0.4 0.6
Q [m³/s] Q [m³/s]
2500 600
2000
P [W]

P [W]
1500
400
1000
500
0 200

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 89 65 86 85 79 79 72 67 59 LwA Inlet 73 57 72 59 63 62 52 46 36
LwA Outlet 87 72 81 83 78 76 72 68 60 LwA Outlet 76 62 75 59 62 56 51 46 36
Measurement point: 0.669 m³/s @ 448 Pa Measurement point: 0.388 m³/s @ 104 Pa

media
For aggressive
Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 0 500 1000 1500 2000 2500 3000 3500 4000
800 200

7973/7974
7975/7976

DVP 400D4-8-L 4 pole DVP 400D4-8-L 8 pole

600 94 150
Ps [Pa]

Ps [Pa]

88
400 100
100

200 89
50

0 0
0 1 2 0 0.3 0.6 0.9 1.2
Q [m³/s]
Q [m³/s]
5000
750
4000
P [W]

3000
P [W]

2000 500
1000
0
250

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 88 69 84 82 80 80 75 72 64 LwA Inlet 78 62 78 65 64 61 54 50 40
LwA Outlet 86 72 77 80 78 79 75 71 63 LwA Outlet 76 63 75 63 65 59 54 49 40
Measurement point: 0.564 m³/s @ 594 Pa Measurement point: 0.567 m³/s @ 103 Pa
332 | Centrifugal Fans

Centrifugal Fans
IE2
2009/640/EG
120°C

1
2

2
Centrifugal

1
fans

General
KBT/KBR thermo fans
KBT with forward curved, KBR with
backward curved impeller blades, for the
extract of air up to a temperature of 120°C.
IEC standard motors, in three phase from
750 W speed controllable via frequency
inverter, smaller and single phase motors
speed controllable by transformers.

KBT/KBR EC thermo fans with highly


efficient EC motor, speed control by 0-10V
signal.
Centrifugal Fans | 333

1 ASF/KB Flexible connection


2 Connection standard
3 KBT/KBR Centrifugal fan
4 WBK Wall mounting bracket
5 WSD Weather protection roof

fans
Centrifugal
KBR/KBT-EC 334
120°C

Thermo Box with EC-motor

KBR/KBT IE2
340
2009/640/EG
120°C

Thermo Box
334 | Centrifugal Fans

KBR EC / KBT EC Electrical


accessories
• EC-motors, high level of efficiency
• 100% speed controllable
• Integrated motor protection
• Low noise level MTP 10
• Max. temp. of continuously transported air 120°C p. 359

The KBR EC fans have impellers manufactured from galvanized steel


with backward-curved blades. The KBT EC fans have impellers man-
ufactured from galvanized steel with forward-curved blades. The
MTV p. 359
casing is manufactured from double-skinned galvanized steel and is
insulated with 50 mm mineral wool.
The KBR EC and KBT EC fans have a swing-out door for easy in-
spection and service. The direction of the door opening can easily be
changed from left to right at site. REV p. 380
Anti-vibration dampers are incorporated into the base frame.

120°C EC-Vent
p. 365

Quick selection
RT p. 377
9748, 9771, 10701, 10699, 10707, 9749

8361 , 8453
1 1 KBT 160EC 3 KBT 200EC
KBR 280 EC
2 KBT 180EC 4 KBT 225EC
2 KBR 315 EC
3 KBR 315 EC-L
5 KBT 250EC CO2RT
4 KBR 355 EC p. 368
5 KBR 355 EC-K
6 KBR 355EC-L
Centrifugal

CXE p. 369
fans

1 2 3 4 5

1 2 5 4 3 6

IR24-P
p. 368

Technical data
KBR EC 280 315 315-L 355 355-K 355-L
KBT EC 160 180 200 225 250
Art. no. 33396 33397 33653 33400 33398 33665 34785 34786 33231 34787 33259
Voltage/Frequency V/50/60 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 3~ 230 1~ 230 1~ 230 1~ 400 3~ 400 3~
Power W 107 182 1268 498 296 2643 188 363 535 794 1252
Current A 0.502 0.772 5.53 2.17 1.3 4.04 0.787 1.52 2.43 1.36 2.01
Max. air flow m3/s 0.426 0.617 1.12 0.997 0.822 1.79 0.284 0.42 0.554 0.723 0.925
R.p.m. min-1 1512 1512 3025 1495 1514 2626 1510 1504 1498 1387 1370
Max. temp. of transported air °C 120 120 120 120 120 120 120 120 120 120 120
Sound pressure level at 4/10 m dB(A) 30/22 26/18 38/30 32/24 24/16 41/33 29/21 32/24 36/28 39/31 37/29
Weight kg 23 57 61 70 70 75 27 27.5 33 35 48
Insulation class, motor B F F B B F B B B B F
Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55
Speed control, stepless MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10 MTP 10
Wiring diagram p. 442-461 46 46 47 48 46 47 46 48 48 27 27
Centrifugal Fans | 335

Dimensions Ventilation
A accessories

F
K
ALS-KBT
p. 414

G
B
C

D 50 ASF/KB

50
33

E L p. 414

38
WBK p. 414

WSD KBT
H

G p. 414
M

KBR EC A B C D E F øG H J K L M
280 172 537 295 360 625 125 280 234 291 70 620 55
315 188 600 339 398 690 125 315 249 307 70 770 55
355 207 655 372 451 770 125 355 273 331 70 770 55

A J
F

fans
Centrifugal
ØG
B
C

D
50

50
E L

38
H

ØG
M

KBT EC A B C D E F øG H J K L M
160 127 382 213 248 435 91 160 149 207 50 470 55
180 134 412 230 269 470 91 200 161 219 50 470 55
200 143 445 249 292 510 91 200 174 232 50 470 55
225 147 455 256 301 522 91 225 193 251 50 620 55
250 160 500 282 333 576 125 250 213 272 70 620 55
336 | Centrifugal Fans

Performance
Q [m³/h] Q [m³/h]
0 300 600 900 1200 1500 0 400 800 1200 1600 2000 2400
400 500

9748/9752

8949/9772
KBR 280EC KBR 315EC
400
300

69 72
300
Ps [Pa]

Ps [Pa]
68
200
76
200 70
66
71

100 55
72 100
62 59
52 64
56 58
0 0 54
0 0.2 0.4 0 0.2 0.4 0.6
Q [m³/s]
Q [m³/s]
200 200
P [W]

P [W]
100 100

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 63 32 45 56 57 56 56 53 47 LwA Inlet 69 46 58 64 65 58 58 55 50
LwA Outlet 64 34 47 59 59 57 56 47 46 LwA Outlet 71 47 59 66 66 61 60 54 48
LwA Surrounding 53 28 42 47 39 44 41 50 31 LwA Surrounding 49 16 39 45 40 45 36 35 25
Measurement point: 0.213 m³/s @ 246 Pa Measurement point: 0.309 m³/s @ 312 Pa

Q [m³/h]
0 1000 2000 3000 4000 Q [m³/h]
2000 0 500 1000 1500 2000 2500 3000 3500
10701/10702

800

10699/10700
Centrifugal

KBR 315EC-L KBR 355EC


1500
600
fans

89 78
Ps [Pa]

Ps [Pa]

1000
400

80
92 73 81
500
83 200
72
75
77 62
62 66
65
0 55
56
0 0.3 0.6 0.9 1.2 0
Q [m³/s] 0 0.25 0.5 0.75 1
Q [m³/s]

600

400
P [W]

200

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 87 63 74 76 85 74 75 72 67 LwA Inlet 74 55 65 69 69 65 62 60 55
LwA Outlet 90 64 72 75 88 81 80 71 66 LwA Outlet 77 60 65 74 68 66 62 59 55
LwA Surrounding 61 41 54 55 56 51 52 48 40 LwA Surrounding 55 26 42 46 45 45 47 50 45
Measurement point: 0.504 m³/s @ 1352 Pa Measurement point: 0.548 m³/s @ 514 Pa
Centrifugal Fans | 337

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 0 1000 2000 3000 4000 5000 6000 7000
600 2000

11279/11281
10707/10708
KBR 355EC-L
KBR 355EC-K
1500 93

400
78

Ps [Pa]
Ps [Pa]

1000
88
93
71
200 81
500 88
61 74 76

78
66
49 60
50 63
0 0
0 0.3 0.6 0.9 0 0.5 1 1.5 2
Q [m³/s] Q [m³/s]
400 4000
P [W]

P [W]
200 2000

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 71 60 62 63 67 61 61 57 51 LwA Inlet 92 63 74 84 85 82 82 85 85
LwA Outlet 71 56 59 64 66 63 59 54 49 LwA Outlet 92 63 73 88 84 83 81 84 84
LwA Surrounding 47 31 35 36 36 45 38 31 24 LwA Surrounding 64 28 46 58 56 56 56 57 54
Measurement point: 0.411 m³/s @ 393 Pa Measurement point: 0.982 m³/s, Ps = 1514 Pa

Q [m³/h] Q [m³/h]
0 200 400 600 800 1000 0 300 600 900 1200 1500
300 300
11731

11726

fans
Centrifugal
KBT 160EC KBT 180EC
250 250

61
200 200
58
Ps [Pa]

Ps [Pa]

58
150 150
56
56
57
100 100
50
45 50
44
50 50
41 42
36 38
34 40
0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0 0.1 0.2 0.3 0.4 0.5
Q [m³/s] Q [m³/s]

300 450
200 300
P [W]

P [W]

100
150
0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 70 - 68 64 61 57 55 51 47 LwA Inlet 73 - 71 67 64 60 58 54 -
LwA Outlet 72 - 70 66 63 59 57 53 49 LwA Outlet 75 - 73 69 66 62 60 56 -
LwA Surrounding 52 - 50 46 43 39 37 33 29 LwA Surrounding 55 - 53 49 46 42 40 36 -
Measurement point: 0.11 m³/s @ 171 Pa Measurement point: 0.18 m³/s @ 233 Pa
338 | Centrifugal Fans

Q [m³/h] Q [m³/h]
0 400 800 1200 1600 2000 0 500 1000 1500 2000 2500
400 500

8361/8362

11850
KBT 200EC KBT 225EC
400
300 76 72

300

Ps [Pa]
Ps [Pa]

73
200 68
81
200 70

66 77 67
100 60
100
59 71
63 56
48
50
0 0
0 0.2 0.4 0.6 0 0.2 0.4 0.6 0.8
Q [m³/s] Q [m³/s]

600
1200
P [W]

800

P [W]
300
400
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 60 59 72 66 68 64 62 56 LwA Inlet 80 - 78 74 71 67 65 61 57
LwA Outlet 77 63 69 74 69 68 64 62 56 LwA Outlet 82 - 80 76 73 69 67 63 59
LwA Surrounding 59 26 23 53 50 49 54 52 42 LwA Surrounding 62 - 60 56 53 49 47 43 39
Measurement point: 0.278 m³/s @ 309 Pa Measurement point: 0.33 m³/s @ 411 Pa

Q [m³/h]
0 500 1000 1500 2000 2500 3000 3500
600
8453/8454
Centrifugal

79
KBT 250EC
500
fans

400
75 86
Ps [Pa]

300

82

200
67
74
100

54 60
0
0 0.25 0.5 0.75 1
Q [m³/s]
2000
P [W]

1000

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 78 51 68 69 69 73 70 69 64
LwA Outlet 80 58 68 73 73 75 71 70 63
LwA Surrounding 60 12 45 51 50 54 53 55 50
Measurement point: 0.472 m³/s @ 531 Pa
Centrifugal Fans | 339

fans
Centrifugal

Reference: Therme Erding, Germany

Therme Erding is the largest thermae and sauna paradise in Europe with 1.5
million visitors every year. The twenty six themed saunas and their technical
set-up are a special feature of this facility.
Products/Solutions: 15 Systemair thermo fans from the KBT range permanently
supply 120°C hot air. The fans are temperature-controlled and are equipped
with frequency inverters. This unconventional technology optimises energy
consumption and lowers operational costs by 30-40%.
340 | Centrifugal Fans

KBT / KBR Electrical


accessories
• Max. temperature of transported air 120°C
• Speed-controllable (except KBR 280D2 & 280D2-4)
• Integral cold conductor (PTC) or thermal contacts (TK)
• Low sound level
REV p. 380
The fans have impellers manufactured from galvanised steel, KBT
with forward-curved blades, KBR with backward-curved blades. The
casing is manufactured from double-skinned galvanised steel and is
insulated with 50 mm mineral wool. RTRD p. 357
KBT/KBR fans have a swing-out door for easy inspection and ser-
vice. The direction of the door opening can easily be changed from
left to right at site. Anti-vibration dampers are incorporated into the
base frame.
To protect the motors from overheating the fans have integral RTRDU p. 357

IE2
2009/640/EG
thermal contacts (TK) or cold conductors (PTC) with external leads
for connection to a triggering device.
120°C

S-DT2 p. 381
Quick selection
qv [m³/h]
0 2000 4000 6000 8000
3000
Ps [Pa]
5201, 5196, 5211, 5239, 6599, 9774, 5246, 9773, 5274, 9769

5290/5302/5310/5311/9765/9766/9767/12287
1 KBT 160DV 5 KBT 200E4 1 KBR 315DV
2 KBT 160E4 6 KBT 225D4 IE2 2 KBR 315D2 IE2
3 KBT 180E4 7 KBT 225E4
2500 3 KBR 355DV STDT p. 373
4 KBT 200DV
4 KBR 355DV/K
8 KBT 250D4 IE2 5 KBR 355D2 IE2
9 KBT 250E4 2000 6 KBR 355D2/K IE2
10 KBT 280D4 IE2 7 KBR 355E4
8 KBR 355E4/K
1500 FRQ p. 361

4 1000

3
500
T p. 378
3 1 2 6 5
5 7 6 9 8 10 7
2 1 8 4
Centrifugal

qv [m³/s]
fans

Technical data S-ET p. 373


KBT 160DV 160E4 180E4 200DV 200E4 225D4 IE2 225E4 250D4 IE2 250E4 280D4 IE2
Art. no. 5823 5976 5824 5825 5826 33556 5828 33557 5830 33558
Voltage/Frequency V/50 Hz 400 3~ 230 1~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~ 230 1~ 400 3~
Connection D/Y – – D/Y – Y – Y – Y
Power (P1) W 243 121 272 567 783 1008 976 1938 1406 3649
Current A 0.57 1.11 1.11 1.76 5.1 1.96 5.5 3.39 10.5 6.05
Starting current A 1.31 2.3 2.3 6.4 18 8.9 18 23 42 32.4
Max. air flow m /s 0.248
3
0.231 0.345 0.488 0.541 0.809 0.653 1.2 1.08 1.63
R.p.m. min-1 1120 1476 1490 1453 1370 1418 1417 1400 1400 1426
Max. temp. of transported air °C 120 120 120 120 120 120 120 120 120 120
Sound pressure level at 4/10 m dB(A) 31/23 31/23 34/26 37/29 37/29 39/31 38/30 44/36 45/37 47/39
Weight kg 25.5 25.5 30 40 40 45 35 58 58 75
Insulation class, motor F F F F F F F F F F
Enclosure class, motor IP 54 IP 54 IP 54 IP 54 IP 54 IP 55 IP 54 IP 55 IP 54 IP 55
Capacitor µF – 6 6 – 30 – 30 – 50 –
Motor protection STDT 16 S-ET 10 S-ET 10 STDT 16 S-ET 10 U-EK 230E S-ET 10 U-EK 230E S-ET 10 U-EK 230E
Speed control, five step RTRD 2 RTRE 1.5 RTRE 1.5 RTRD 2 RTRE 7 – RTRE 7 – RTRE 12 –
Speed control, D/Y two step 400V S-DT2 – – S-DT2 – – – – – –
Speed control, frequency FRQ – – FRQ – FRQ – FRQ – FRQ
converter*
Wiring diagram p. 442-461 17c 21 21 17c 21 17a 21 17a 21 17a
* Frequency converters are available with or without sine filter, and stepless or with five step switch (see page 361).
Centrifugal Fans | 341

Dimensions Ventilation
accessories
K

F
ALS-KBT
p. 414

L
ASF/KB
p. 414

WBK p. 414

KBR A B C D E F øG H J K L M
280 172 537 295 360 625 125 280 234 291 70 620 55
315 188 600 339 398 690 125 315 249 307 70 770 55
WSD KBT
p. 414
M

355 207 655 372 451 770 125 355 273 331 70 770 55

KBT A B C D E F øG H J K L M
160 127 382 213 248 435 91 160 149 207 50 470 55
180 134 412 230 269 470 91 200 161 219 50 470 55
200 143 445 249 292 510 91 200 174 232 50 470 55
225 147 455 256 301 522 91 225 193 251 50 620 55
250 160 500 282 333 576 125 250 213 272 70 620 55
280 172 537 295 360 625 125 280 234 291 70 620 55

fans
Centrifugal
KBR 280DV 280D2 280D2-4 315DV 315D2 IE2 355DV 355DV/K 355D2 IE2 355D2/K 355E4 355E4/K
IE2
Art. no. 31557 31556 31555 5833 33559 5835 5977 33560 33561 5980 5978
Voltage/Frequency V/50 Hz 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 230 1~ 230 1~
Connection D/Y Y Y/YY D/Y Y D/Y D/Y D Y – –
Power (P1) W 209 730 783/99.4 244 1225 370 323 3670 2126 438 319
Current A 1.33 1.25 1.2/0.33 1.39 2.31 1.39 1.39 6.16 3.72 2.1 2.1
Starting current A 4.6 11.4 – 4.6 22.4 4.6 4.6 46.8 30.9 4.9 4.9
Max. air flow m3/s 0.43 0.824 0.80/0.422 0.611 1.15 1.06 0.82 2.09 1.62 0.972 0.778
R.p.m. min-1 1476 2820 2800/1410 1360 2929 1360 1434 2887 2899 1330 1330
Max. temp. of transported air °C 120 120 120 120 120 120 120 120 120 120 120
Sound pressure level at dB(A) 33/25 44/36 44/33 / 36/28 50/42 41/33 41/33 53/45 53/45 41/33 41/33
4/10 m 36/25
Weight kg 25 54 47 58 68 72 72 93 77 72 72
Insulation class, motor F F F F F F F F F F F
Enclosure class, motor IP 54 IP 55 IP 55 IP 54 IP 55 IP 54 IP 54 IP 54 IP 55 IP 54 IP 54
Capacitor µF – – – – – – – – – 12 12
Motor protection STDT 16 – – – U-EK 230E STDT 16 STDT 16 U-EK 230E U-EK 230E S-ET 10 S-ET 10
Speed control, five step RTRD 2 – – – – RTRD 2 RTRD 2 – – RTRE 3 RTRE 3
Speed control, D/Y two step S-DT2 – – – – S-DT2 S-DT2 – – – –
400V
Speed control, frequency FRQ FRQ FRQ FRQ FRQ FRQ FRQ FRQ FRQ – –
converter*
Wiring diagram p. 442-461 17c 17a 14b 17c 17a 17c 17c 17b 17a 21 21
* Frequency converters are available with or without sine filter, and stepless or with five step switch (see page 361).
342 | Centrifugal Fans

Performance
Q [m³/h] Q [m³/h]
0 200 400 600 800 0 200 400 600 800
200 200

5196
5201
KBT 160DV KBT 160E4

150 150

Ps [Pa]
Ps [Pa]

100
100

50
50

2 3 4 5 1 2 3 4 5
0
0 0 0.04 0.08 0.12 0.16 0.2 0.24
0 0.05 0.1 0.15 0.2 0.25
Q [m³/s] Q [m³/s]

300 200
5
200 5
P [W]

P [W]
100
3 3
100

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 72 – 70 66 63 59 57 53 49 LwA Inlet 72 – 70 66 63 59 57 53 49
LwA Outlet 74 – 72 68 65 61 59 55 51 LwA Outlet 74 – 72 68 65 61 59 55 51
LwA Surrounding 54 – 52 48 45 41 39 35 31 LwA Surrounding 54 – 52 48 45 41 39 35 31
Measurement point: 0.136 m³/s @ 152 Pa Measurement point: 0.127 m³/s @ 154 Pa

Q [m³/h] Q [m³/h]
0 250 500 750 1000 1250 0 300 600 900 1200 1500
250 400
5211

5239
Centrifugal

KBT 180E4 KBT 200DV


200
300
fans

150
Ps [Pa]

Ps [Pa]

200

100

100
50

1 2 3 4 5 2 3 4 5
0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0 0.1 0.2 0.3 0.4 0.5
Q [m³/s] Q [m³/s]
300 1000
5
P [W]

200
P [W]

5
100 3 3

0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 75 – 73 69 66 62 60 56 – LwA Inlet 78 – 76 72 69 65 63 59 55
LwA Outlet 77 – 75 71 68 64 62 58 – LwA Outlet 80 – 78 74 71 67 65 61 57
LwA Surrounding 57 – 55 51 48 44 42 38 – LwA Surrounding 60 – 58 54 51 47 45 41 37
Measurement point: 0.19 m³/s @ 203 Pa Measurement point: 0.268 m³/s @ 286 Pa
Centrifugal Fans | 343

Q [m³/h] Q [m³/h]
0 400 800 1200 1600 2000 0 1080 2160 3240
300 400

6599
KBT 225D4 IE2
KBT 200E4
250

300
200
Ps [Pa]

Ps [Pa]
150 200

100

100
50

1 2 34 5
0
0
0 0.1 0.2 0.3 0.4 0.5 0.6
0 0.3 0. .9
Q [m³/s]
Q [m³/s]
1000 1500
5
P [W]

1000

P [W]
3
500
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k

LwA Inlet 78 – 76 72 69 65 63 59 55 LwA Inlet 81 - 79 75 72 68 66 62 58

LwA Outlet 80 – 78 74 71 67 65 61 57 LwA Outlet 83 - 81 77 74 70 68 64 60

LwA Surrounding 60 – 58 54 51 47 45 41 37 LwA Surrounding 63 - 61 57 54 50 48 44 40

Measurement point: 0.313 m³/s @ 259 Pa Measurement point: 0.364 m³/s @ 373 Pa

Q [m³/h]
0 500 1000 1500 2000 2500
500
5246

fans
Centrifugal
KBT 225E4
400

300
Ps [Pa]

200

100

1 2 3 4 5
0
0 0.2 0.4 0.6 0.8
Q [m³/s]
1000
5
P [W]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 – 80 76 73 69 67 63 59 LwA Inlet 85 - 83 79 76 72 70 66 62
LwA Outlet 84 – 82 78 75 71 69 65 61 LwA Outlet 87 - 85 81 78 74 72 68 64
LwA Surrounding 64 – 62 58 55 51 49 45 41 LwA Surrounding 67 - 65 61 58 54 52 48 44
Measurement point: 0.389 m³/s @ 338 Pa Measurement point: 0.419 m³/s @ 517 Pa
344 | Centrifugal Fans

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 3500 4000 0 1000 2000 3000 4000 5000 6000
500 800

9769
5274
KBT 250E4 KBT 280D4 IE2
400
600

300
Ps [Pa]

Ps [Pa]
400

200 5

4
3 200
100
2
1

0 0
0 0.2 0.4 0.6 0.8 1 1.2 0 0.5 1 1.5
Q [m³/s] Q [m³/s]

2000 4000

P [W]
P [W]

1000 2000
2
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 86 – 84 80 77 73 71 67 63 LwA Inlet 88 - 86 82 79 75 73 69 65
LwA Outlet 88 – 86 82 79 75 73 69 65 LwA Outlet 90 - 88 84 81 77 75 71 67
LwA Surrounding 68 – 66 62 59 55 53 49 45 LwA Surrounding 70 - 68 64 61 57 55 51 45
Measurement point: 0.562 m³/s @ 467 Pa Measurement point: 0.653 m³/s @ 665 Pa

Q [m³/h] Q [m³/h]
0 300 600 900 1200 1500 1800 2100 0 500 1000 1500 2000 2500 3000 3500 4000
350 1400

300 KBR 280DV 1200 KBR 280D2-4

250 1000
Centrifugal

200 800
Ps [Pa]
Ps [Pa]
fans

150 600
2-pole

100 400

4-pole
50 200

0 0
0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.2 0.4 0.6 0.8 1 1.2

Q [m³/s] Q [m³/s]

0 0
250
P [W]

100
P [W]

500
200 750

300 1000

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 2-pole 63 125 250 500 1k 2k 4k 8k
LwA Inlet 74 – 68 66 62 59 57 53 49 LwA Inlet 86 - 80 78 74 71 69 65 61
LwA Outlet 76 – 70 68 64 61 59 55 51 LwA Outlet 88 - 82 80 76 73 71 67 61
LwA Surrounding 56 – 50 48 44 41 39 35 31 LwA Surrounding 67 - 61 59 55 52 50 46 42
Measurement point: 0.215 m³/s @ 224 Pa Measurement point: 0.407 m³/s @ 851 Pa
4-pole
LwA Inlet 74 - 68 66 62 59 57 53 49
LwA Outlet 76 - 70 68 64 61 59 55 51
LwA Surrounding 56 - 50 48 44 41 39 35 31
Measurement point: 0.2 m³/s @ 242 Pa
Centrifugal Fans | 345

Q [m³/h] Q [m³/h]
0 400 800 1200 1600 2000 2400 0 1000 2000 3000 4000
400 1600

9767
5290
1400
KBR 315DV
KBR 315D2 IE2
300 1200

1000

Ps [Pa]
Ps [Pa]

200 800

600

100 400

200
1 2 3 4 5
0 0
0 0.2 0.4 0.6 0 0.3 0.6 0.9 1.2
Q [m³/s] Q [m³/s]
300 1500
5
200
P [W]

P [W]
2 1000
100

0 500

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 77 – 75 74 69 67 63 57 54 LwA Inlet 91 - 89 88 83 81 77 71 68
LwA Outlet 79 – 77 76 71 68 65 59 56 LwA Outlet 93 - 91 90 85 83 80 73 70
LwA Surrounding 59 – 57 56 51 49 45 39 36 LwA Surrounding 73 - 71 70 65 63 59 53 50
Measurement point: 0.301 m³/s @ 286 Pa Measurement point: 0.516 m³/s @ 1260 Pa

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 3500 0 1000 2000 3000
700 600

5310
12287

600 KBR 355DV KBR 355DV/K


500

fans
Centrifugal
500
400

400
Ps [Pa]
Ps [Pa]

300
300

200
200

100
100

1 2 3 4 5 1 2 3 4 5
0 0
0 0.25 0.5 0.75 1 0 0.3 0.6 0.9
Q [m³/s] Q [m³/s]
600 400
5 5
400
300
P [W]

P [W]

3 3
200
200
100
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 – 80 79 74 72 68 62 59 LwA Inlet 82 - 80 79 74 72 68 62 59
LwA Outlet 84 – 82 81 76 74 70 64 61 LwA Outlet 84 - 82 81 76 74 70 64 61
LwA Surrounding 64 – 62 61 56 54 50 44 41 LwA Surrounding 64 - 62 61 56 54 50 44 41
Measurement point: 0.485 m³/s @ 438 Pa Measurement point: 0.451 m3/s @ 323 Pa
346 | Centrifugal Fans

Q [m³/h] Q [m³/h]
0 2000 4000 6000 8000 0 1000 2000 3000 4000 5000 6000
2000

9766
2500

9765
KBR 355D2/K IE2
KBR 355D2 IE2
2000 1500

1500

Ps [Pa]
Ps [Pa]

1000

1000

500
500

0 0
0 1 2 0 0.5 1 1.5
Q [m³/s] Q [m³/s]

4000 2500
3000 2000

P [W]
P [W]

1500
2000
1000
1000 500
0 0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 94 - 92 91 86 84 80 74 71 LwA Inlet 94 - 92 91 86 84 80 74 71
LwA Outlet 96 - 94 93 88 86 82 76 73 LwA Outlet 96 - 94 93 88 86 82 76 73
LwA Surrounding 76 - 74 73 68 66 62 56 53 LwA Surrounding 76 - 74 73 68 66 62 56 53
Measurement point: 1.04 m³/s @ 1848 Pa Measurement point: 0.81 m³/s @ 1457 Pa

Q [m³/h] Q [m³/h]
0 500 1000 1500 2000 2500 3000 3500 0 500 1000 1500 2000 2500
600 600

5302
5311
Centrifugal

500 KBR 355E4 500 KBR 355E4/K


fans

400 400
Ps [Pa]
Ps [Pa]

300 300

200 200

100 100

5 1 2 3 4 5
1 2 3 4 0
0
0 0.2 0.4 0.6 0.8
0 0.25 0.5 0.75 1
Q [m³/s] Q [m³/s]
400
500 5
400 300
5
P [W]

3
P [W]

300 3 200
200 100
100
0
0

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 82 – 80 79 74 72 68 62 59 LwA Inlet 80 – 78 74 71 67 65 61 57
LwA Outlet 84 – 82 81 76 74 70 64 61 LwA Outlet 82 – 80 76 73 69 67 63 59
LwA Surrounding 64 – 62 61 56 54 50 44 41 LwA Surrounding 62 – 60 56 53 49 47 43 39
Measurement point: 0.494 m³/s @ 408 Pa Measurement point: 0.43 m³/s @ 326 Pa
Centrifugal Fans | 347

Reference: VM-Mountain, Denmark

VM-Mountain is the name of the world’s most advanced and award winning
building. The building has until now won 4 major international architecture
awards.
The 38 year old architect Bjarke Ingels, who is one of Denmark’s most promising

fans
Centrifugal
architect talents, was commissioned to design a non-conventional building in
Copenhagen with an integrated multi-storey car park.
He designed a building where the facades face in different directions and
appartments are arranged in the shape of mountain terraces, all on top of a
multi-storey car park.
All apartments have unobstructed views and have a terrace and a small garden.
Products/Solutions: Systemair supplied VM-Mountain with MUB fans complete
with Cebecon5 control system & accessories, also supplied were WVA smoke
extract units and our K range of duct fans.
348 | Domestic Fans

Domestic Fans
Domestic
fans

General BF axial fan, CBF centrifugal fan IF inline axial fan


Domestic fans for the ventilation of Casing manufactured from sturdy ABS Booster fan for duct mounting, with single
bathrooms, toilets and storage rooms. plastic. Available in standard exhaust phase induction motors.
Can be wall or window mounted and in fan version, with timer or with timer and
some cases duct mounted. humidity sensor.

BF-W axial fan


Casing manufactured from sturdy ABS
plastic. For wall or window mounting. Back
draught damper included.
Domestic Fans | 349

Installation through a window

4
1 Auto shutter

2 Back cover with grill


2 3 Fan unit

4 Window
3

fans
Domestic
BF-W 350 CBF 352

Window or wall mounted Fans for bathrooms, toilets


fans for bathrooms, toilets and storage rooms
and storage rooms

BF 352 IF 352

Fans for bathrooms, Fans for bathrooms,


toilets and shower rooms toilets and storage rooms
350 | Domestic Fans

BF-W
BF-W axial flow fans for window mounting. Suitable for a variety of ap-
plications including bathrooms, kitchens and utility rooms in restaurants,
offices and shops.
Casing manufactured from high impact resistant ABS thermoplastics
for durability and easy cleaning.
Single phase induction motors with pre-lubricated, maintenance free
bearings.
With thermo-activated internal shutter, opening 45 seconds after the
BF-W 230A fan has been switched on.

BF-W 120A

Dimensions

X = In, Y = Out

D
X Y

B C B C A

Wall mounting Window mounting

BF-W A B C D
100A 163 90 30 98
120A 182 92 32 118
150A 203 105 23 150
Domestic

230A 286 125 25 230


300A 362 145 29 300
fans

Technical data
BF-W 100A 120A 150A 230A 300A
Art. no. 7200 7202 7204 7206 7219
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 14.8 13.9 30.8 41.7 70.8
Current A 0.0899 0.0899 0.19 0.197 0.32
Max. air flow m3/s 0.0191 0.023 0.0641 0.124 0.192
R.p.m. min-1 2468 2198 2253 1155 1035
Max. temp. of transported air °C 70 57 64 61 70
“ when speed controlled °C 70 57 64 61 70
Sound pressure level at 3 m dB(A) 45 48 54 53 55
Weight kg 1 1.2 1.5 3.1 5.2
Insulation class, motor B B B B B
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44
Capacitor µF – – – 2 3.15
Domestic Fans | 351

Performance Q [m³/h] Q [m³/h]


0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80
25 28

4468

4479
BF-W 100A BF-W 120A
24
20

20

15
16
Ps [Pa]

Ps [Pa]
65

12
10

60
8

5 66
58
4

0 0
0 0.005 0.01 0.015 0.02 0 0.005 0.01 0.015 0.02 0.025
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 52 12 42 47 47 43 40 36 29 LwA Inlet 55 18 48 47 49 48 45 38 31
LwA Outlet 59 40 54 55 53 44 41 35 28 LwA Outlet 62 42 57 57 56 50 47 36 29
Measurement point: 0.00573 m³/s @ 9.54 Pa Measurement point: 0.0092 m³/s @ 15.1 Pa

Q [m³/h] Q [m³/h]
0 50 100 150 200 250 0 100 200 300 400 500
60 40

8643/8644
4470

BF-W 150A BF-W 230A


50

30

40
Ps [Pa]

Ps [Pa]

68
30 20
68

20
68
10 69
10

0 0
0 0.02 0.04 0.06 0.08 0 0.04 0.08 0.12 0.16
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 60 18 49 54 56 54 50 43 34 LwA Inlet 60 37 47 52 54 55 52 46 38
LwA Outlet 66 43 59 63 60 50 50 42 31 LwA Outlet 61 37 47 50 54 58 53 47 40

fans
Domestic
Measurement point: 0.0353 m³/s @ 25.2 Pa Measurement point: 0.0556 m³/s @ 21.8 Pa

Q [m³/h]
0 100 200 300 400 500 600 700
50
8633/8634

BF-W 300A

40

30
Ps [Pa]

20 71

10 72

0
0 0.05 0.1 0.15 0.2
Q [m³/s]

dB(A) Tot Frequency bands [Hz]


63 125 250 500 1k 2k 4k 8k
LwA Inlet 65 55 59 58 58 58 54 49 40
LwA Outlet 66 54 60 59 58 59 55 50 42
Measurement point: 0.0959 m³/s @ 22 Pa
352 | Domestic Fans

BF / CBF
The BF/CBF units are extraction fans manufactured from ABS plastic.
Suitable for wall or ceiling mounting. These fans, can be connected
either via the light switch, so that they start when the light is turned
on, or to a separate switch. The CBF has a spring-loaded back draft
damper.
There are three models: standard model (S), a model with timer
(T) and a model with timer and humidity sensor (TH). A time delay
of between 1 and 20 minutes can be set by removing the unit’s
front cover. The humidity sensor can be set to a value between 40
and 95% relative humidity. The BF fan has an adjustment knob that
is easily accessible at the bottom of the fan. To adjust the humidity
sensor on the CBF fan, the front cover should be removed first.

Dimensions
BF CBF 100L

BF £A øB C
100 163 98 60
120 182 118 40
150 203 150 81

IF
Dimensions
IF in-line axial fan, suitable for bathrooms,
toilets and shower rooms. The IF series
are in-line extractor fans designed for the
safe ventilation of bathrooms, toilets and
shower rooms. Manufactured from high
impact ABS thermoplastic. The series is
suitable for boosting a BF fan where a
longer run of ducting is used. IF øA B
Domestic

The IF fans have single-phase induc- 100 100 90


fans

tion motors with sealed for life bearings. 120 118 99


150 150 110

Technical data
BF 100 BF 120 BF 150 CBF 100L IF 100 IF 120 IF 150
Art. no. standard 5950 5951 5952 5959 5962 5963 5964
Art. no. BF + timer 5953 5954 5955 5960 – – –
Art. no. + timer and humidity sensor 5956 5957 5958 5961 – – –
Voltage/Frequency V/50 Hz 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
Power W 14.8 13.9 30.8 29.1 14 25 25
Current A 0.09 0.09 0.19 0.19 – – –
Max. air flow m /s 0.0191
3
0.023 0.0641 0.0291 0.0242 0.0361 0.0667
R.p.m. min-1 2468 2198 2253 2403 2432 2000 2400
Max. temp. of transported air °C 70 57.4 63.9 57.3 – – –
“ when speed controlled °C 70 57.4 63.9 57.3 – – –
Sound pressure level at 3 m dB(A) 45 48 54 52 41 41 40
Weight kg 0.7 0.8 1 1.2 0.5 0.6 0.7
Insulation class, motor B B B B – – –
Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Domestic Fans | 353

Performance
Q [m³/h] Q [m³/h]
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80
25 30

4479
4468
BF 100 BF 120S
25
20

20
15

Ps [Pa]
Ps [Pa]

15 65

10
10
60

5 66
58 5

0 0
0 0.005 0.01 0.015 0.02 0 0.005 0.01 0.015 0.02 0.025
Q [m³/s] Q [m³/s]

dB(A) Tot Frequency bands [Hz] dB(A) Tot Frequency bands [Hz]
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
LwA Inlet 52 12 42 47 47 43 40 36 29 LwA Inlet 55 18 48 47 49 48 45 38 31
LwA Outlet 59 40 54 55 53 44 41 35 28 LwA Outlet 62 42 57 57 56 50 47 36 29
Measurement point: 0.00573 m³/s @ 9.54 Pa Measurement point: 0.0092 m³/s @ 15.1 Pa
Q [m³/h]
0 30 60 90 120 150 180 210 240 270
60
4470

BF 150
50

40
Ps [Pa]

30
68

20
68

10

Q [m³/h]
0 0 50 100 150 200 250
0 0.02 0.04 0.06 0.08 40

5579/5580/5590/5591/5594/5595
Q [m³/s]
1 IF 100
35
2 IF 120
dB(A) Tot Frequency bands [Hz] 3 IF 150
30
63 125 250 500 1k 2k 4k 8k
LwA Inlet 60 18 49 54 56 54 50 43 34 25
Ps [Pa]

LwA Outlet 66 43 59 63 60 50 50 42 31 20

fans
Domestic
Measurement point: 0.0353 m³/s @ 25.2 Pa
15

Q [m³/h]
0 20 40 60 80 100 10
120
4471

CBF 100L 5
1 2 3
100
0
0 0.02 0.04 0.06 0.08
Q [m³/s]
80
63
Ps [Pa]

dB(A) Tot Frequency bands [Hz]


60
IF 100 63 125 250 500 1k 2k 4k 8k
61
40
LwA Inlet 63 35 59 60 51 44 38 36 26
LwA Outlet 62 40 61 54 52 45 40 39 32
20 Measurement point: 0.0169 m³/s @ 7.88 Pa
IF 120
0
0 0.005 0.01 0.015 0.02 0.025 0.03 LwA Inlet 59 36 51 53 56 48 42 40 29
Q [m³/s] LwA Outlet 59 28 52 55 54 46 45 46 40

dB(A) Tot Frequency bands [Hz] Measurement point: 0.0304 m³/s @ 8.08 Pa

63 125 250 500 1k 2k 4k 8k IF 150

LwA Inlet 59 16 40 50 55 55 49 44 35 LwA Inlet 63 32 60 57 55 47 41 39 29

LwA Outlet 61 40 54 57 55 53 43 37 27 LwA Outlet 63 39 60 58 57 46 43 42 32


Measurement point: 0.0146 m³/s @ 71.2 Pa Measurement point: 0.0346 m³/s @ 15.2 Pa
354 | Electrical Accessories

Electrical Accessories
accessories
Electrical

Speed controls, transformers EC-Vent Motor protection

Frequency converters Sensors and thermostats Temperature controls


Electrical Accessories | 355

Isolators Electrical actuators Sensors and thermostats accessories


Electrical

Switching devices Push buttons and fire switches


356 | Electrical Accessories

RE RTRE REU
Manual five-step Manual five-step Manual five-step
transformer (230V) transformer (230V) transformer (230V)
A single-phase transformer (with motor protection) A single-phase transformer
which controls the fan speed A single-phase transform- which controls the fan speed
by altering the supply volt- er which controls the fan by altering the supply voltage
age in five fixed steps. The speed by altering the supply in five fixed steps. The steps
steps are adjusted manually, voltage in five fixed steps. are adjusted manually, using the control
using the control knob on the front of the The steps are adjusted manually, using the knob on the front of the unit. There are two
unit. The transformer has 230V terminals for control knob on the front of the unit. An control switches: one for higher fan speeds
operating dampers, electric heater batter- integral motor protection device is included and one for lower fan speeds. Switching
ies or other external equipment. When the which cuts the supply voltage to the fan if between the high and low settings is done
transformer knob is in position 0, the outlet the thermal contact in the fan motor is acti- by an external change-over contact, which
has no current. The indicator lamp on the vated. The unit is reset by turning the knob could be a thermostat or a timer. The in-
front shows that the transformer is in opera- to “0” for 10 seconds, after which the unit dicator lamp on the front shows when the
tion. The fuse may be reset from outside. restarts. transformer is in operation. The fuse may
The RE has a self extinguishing thermoplas- The unit has input terminals for room be reset from outside. The REU has a self-
tic casing. thermostat RT, which stops the supply volt- extinguishing thermoplastic casing. Supply
NOTE! Fans with external contact leads age to the fan when the circuit is broken. voltage: 230V 50/60Hz.
(TK) must always be connected to a motor These terminals are linked before delivery. NOTE! Fans with external thermal contact
protection device. The transformer has 230V terminals for op- leads (TK) must always be connected to a
erating dampers, electric water-heater bat- motor protection device.
teries or other external equipment. These
Output voltages for each of the 5 steps:
terminals have no current when the trans- Output voltages for each of the 5 steps:
Step 1 2 3 4 5
former knob is in position 0, or when the Step 1 2 3 4 5
Voltage 80 105 130 160 230
TK or RT input is open. The indicator lamp Voltage 80 105 130 160 230
on the front shows when the transformer
is in operation. The fuse may be reset from
RE Art. no. Current Enclosure outside. The RTRE has a self-extinguishing REU Art. no. Current Enclosure
1,5 5000 1,5A IP 54 thermoplastic casing. Supply voltage: 230V
1,5 5004 1,5A IP 54
3 5001 3A IP 54 50/60Hz.
3 5005 3A IP 54
5 5002 5A IP 54 5 5006 5A IP 54
7 5003 7A IP 54 Output voltages for each of the 5 steps: 7 5007 7A IP 54
Step 1 2 3 4 5
Voltage 80 105 130 160 230
RE Width Height Depth Weight, kg REU Width Height Depth Weight, kg
1.5 105 200 105 1.5 1.5 105 200 105 2
RTRE Art. no. Current Enclosure
3 105 200 105 2.5 3 105 275 145 4.05
1,5 5008 1,5A IP 54
5 105 200 105 4.1 5 105 275 145 4.9
3 5009 3A IP 54
7 147 257 145 7.5 7 105 275 145 7.05
5 5010 5A IP 54
7 5011 7A IP 54
12 6133 12A IP 54

RTRE Width Height Depth Weight, kg


1.5 105 203 106 2
3 105 203 106 2.6
Fan Earth Supply
Transmisson Supply Earth
Fan 5 105 203 106 4.2 voltage
voltage
7 147 278 140 7.2
1. Switching contact
12 147 278 140 10.5
2. Low speed contact
Transmisson: between ~ and N is always 230V
accessories

3. High speed contact


when the transformer handle is in pos. 1-5
Electrical

NOTE! A switching contact has to be connected

Supply volt- Earth Fan Thermo- Motor pro-


age stat tection
Transmission

Transmis- Supply Earth Fan Thermo- Motor pro-


son voltage stat tection

Transmisson: between ~ and N is always 230V


when the transformer handle is in pos. 1-5
Electrical Accessories | 357

RTRD RTRDU REE


Manual five- Manual five-step Thyristor speed con-
step transformer transformer (400V) troller (230V)
(400V) (With motor protection). REE 1 or REE 2 - surface- or
(With motor protec- A three-phase transformer flush mounting
tion). which controls the fan speed by al- REE4 - only surface mounting
A three-phase transformer which controls tering the supply voltage in five fixed steps. For the manual control of speed and air flow
the fan speed by altering the supply voltage The steps are adjusted manually, using the of electrical fans, AC-induction motors of uni-
in five fixed steps. The steps are adjusted control knobs on the front of the unit. versal motor- and permanent-capacitor type.
manually, using the control knob on the There are two control knobs: one for The jetproof IP 54 enclosure is achieved with
front of the unit. higher fan speeds and one for lower fan the included surface mounting case. (Flush
An integral motor protection device is in- speeds. Switching between the high and mounting without the surface mounting case,
cluded which cuts the supply voltage to the low settings is done by an external change- gives a splash proof IP 44 enclosure also
fan if the thermal contact in the fan motor over contact, which could be a thermostat suitable for highly demanding enviroments
is activated. The unit is reset by turning the or a timer. as bathrooms etc.) Several motors can be
knob to “0” for 10 seconds, after which the An integral motor protection device is in- connected in parallel as long as the total cur-
unit restarts. cluded which cuts the supply voltage to the rent does not exceed current range. Starting
Input terminals for room thermostat RT fan if the thermal contact in the fan motor currents must be considered when choosing
and frost protection thermostat FS cut sup- is activated. The unit is reset by turning the speed controller type. Fans to be used with
ply voltage to the fan when the circuit is switch to “0” for 10 seconds, after which the this controller require a built-in overheating
broken. When the frost protection ther- unit restarts. protection and should be designed for thyris-
mostat FS breaks the circuit, it is reset in Input terminals for room thermostat RT tor speed control.
the same way as when the TK is triggered. cuts supply voltage to the fan when the
Terminals are linked before delivery. The circuit is broken. Terminals are linked before REE 1 REE 2 REE 4
indicator lamp on the front shows that the delivery. The indicator lamp on the front Art. no. 5314 5316 5317
transformer is in operation. The transformer shows when the transformer is in operation.
Voltage V 230 1~ 230 1~ 230 1~
has 230V terminals for operating dampers, The transformer has 230V terminals for
Frequency Hz 50...60 50...60 50...60
electric heater batteries or other external operating dampers, electric heater bat-
teries or other external equipment. These Current A 0.1-1.0 0.1-2.0 0.4-4.0
equipment. These terminals have no current
terminals have no current when the trans- Fuse A 1.25 2.5 5
when the transformer knob is in position 0,
or when the TK or RT input is open. Supply former switch is in position 0, or when the Enclosure IP 54 54 54
voltage: 400V 50/60Hz. TK or RT input is open. Supply voltage: 400V WxHxD mm 82x82x65 82x82x65 82x82x65
50/60Hz. Weight kg 0.25 0.25 0.25
Output voltages for each of the 5 steps:
Step 1 2 3 4 5
Output voltages for each of the 5 steps:
Voltage 95 145 190 240 400
Step 1 2 3 4 5
Voltage 95 145 190 240 400
RTRD Art. no. Current Enclosure
2 5941 2A IP 54
RTRDU Art. no. Current Enclosure
3 32594 3A IP 54
2 5945 2A IP 21
4 5942 4A IP 21
4 5946 4A IP 21
5,2 32399 5,2A IP 54
7 5947 7A IP 21
7 5943 7A IP 21
14 5944 14A IP 21 RTRDU Width Height Depth Weight, kg
2 270 323 163 8
RTRD Width Height Depth Weight, kg
4 270 323 163 12
2 240 284 132 7.4
7 270 323 163 16.5
3 270 323 172 11
4 270 323 173 11
accessories
Electrical

5.2 270 323 172 15.6


7 270 323 172 16
14 450 290 174 32

Line L state connection with cutting function on


the speed control.

Broken line (L) state connection without cutting


function.

External change-over
contact
2. 230V
358 | Electrical Accessories

REE TR0 REE S0


Thyristor speed Thyristor power unit High voltage:
controller (230V) (230V) 1 L: main supply 230V AC / 50Hz - INPUT
2 N: neutral - INPUT
Stepless phase cutting con- Stepless phase cutting contol-
3 L1: 230V AC not regulated to motor
troller for 1~230V/50Hz mo- ler for 1~230V/50Hz motors. It
(after fuse) - OUTPUT
tors. It has a potentiometer has a connection for an exter-
4 Earth Terminal
to set the speed and control lamps for op- nal control signal 0...10V or 4...20mA. The
5 M: regulated output to motor - OUTPUT
eration and alarm. Internal potentiometer to control signal can be choosen by an internal
6 N: neutral to motor - OUTPUT
set a min. speed. On/off switch with control switch. Internal potentiometer to set a min
lamp. Connection for on/off switch, alarm speed. On/off switch with control lamp.
Low voltage:
and thermal contacts. White plastic casing White plastic casing IP54. Several motors
11-12 On / Off switch
IP54. Several motors can be connected in can be connected in parallel as long as the
13 GND
parallel as long as the total current does not total current does not exceed the current
14 U: control signal 0..10V DC (impedanz
exceed the current range. Fans to be used range. Fans to be used with this control-
90 kOhm) / I: 0..20mA (impedanz 250
with this controller must be designed for ler require built in overheat protection and
Ohm)
thyristor speed control. should be designed for thyristor speed con-
15 +V: low voltage power supply 12V DC /
NOTE: phase cutting controller can gener- trol.
1mA for external potentiometer
ate electronic noise! NOTE: phase cutting controller can gener-
16 switch up: 0..10V signal
ate electronic noise!
REE 050TR0 100TR0 switch down: 10..0V signal
Art. no. 2674 2675 17 switch up: disable off-level
Voltage V 230 1~ 230 1~ REE 030S0 050S0 100S0 switch down: enable off-level
Current A 0.5...5 1...10 Art. no. 2676 2677 2678 18 switch up: disable kickstart
Fuse A FF8 FF14 Voltage V 230 1~ 230 1~ 230 1~ switch down: enable kickstart
Current A 0.3...3 0.5...5 1...10 19 switch up: Currentsignal 0..20mA
Enclosure IP 54 54
Control signal 0...10VDC/4...20mA
switch down: Voltagesignal 0..10V
Weight kg 0.8 0.8
20 Off level adjustment potentiometer
Fuse A FF4 FF8 FF14
0..4V or 10..6V (depending on switch 16)
Enclosure IP 54 54 54
21 Min. speed adjustment 60..160V
Weight kg 0.8 1.0 1.0 Max. speed ajustment 165..230V
L N L1 N FT FT N A TK TK U1 N
LED On: normal operation
Pe Blinking: standby (input signal > off-level)
230 VAC Alarm out
230 VAC
50/60 Hz output T M

L1-N:
Input to bypass the on/off contact
230 V non-controlled output

FT-FT
Connection for thermostat, timer, frostprotection,
on/off-switch at a distance

N-A
Alarm output in case of motor fault
230 VAC, 2A

TK-TK
Input thermal contacts of the motor
accessories
Electrical
Electrical Accessories | 359

RADT RADT…
5-step-transformer
with control input
(400V) 1 2 3 4 5 6 D1 D1 TB TB N N L L L1 L2 L3 U V W

A three-phase transformer which controls 2* 2*

the fan speed by altering the supply voltage


Step
in five fixed steps. The steps are adjusted 5 4 3 2 1 230VAC
max. 1A
by an external 0..10V control signal or by a Contact rating
SRE5 1 2 3 4 5 6
potentiometer. Supply voltage +10V. Main J1...J4
switch on the front of the unit. An integral D > N L1 L2 L3 PE

motor protection device is included which Line


cuts the supply voltage to the fan if the 1* 5 step thermostat 3~ 400V 50/60Hz

thermal contact in the fan motor is acti-


vated. The unit is reset by turning the knob
+
to “0” for 10 seconds, after which the unit Output Input
restarts. +10V (Imax=10mA) 0...10V (Ri>100k)
U V W PE
M
Input terminals for on/off cut supply voltage J1...J4 0 1 3~
to the fan when the circuit is broken. The 10K
TB
Y bzw.
E TB or D
indicator lamp on the front shows when the
transformer is in operation. The transformer 1*

has 230V terminals for operating dampers, Extern desired value On/off
RDNT07K1
3~motor with internal
thermostat
electric heater batteries or other external 21.06.2006

equipment. These terminals have no current


1* Function change by changing the position 2* If function is not needed, terminal must
when the transformer knob is in position 0,
of the switch be bridged
or when the on/off input is open.

RADT 2V 4V 7V
Art. no. 30671 30672 30673
Voltage V 400 3~ 400 3~ 400 3~ MTV 1/010 MTP 10
Frequency Hz 50/60 50/60 50/60
Speed controller Speed controller
Current A 2 4 7
Control signal 0...10VDC
Enclosure IP 21 21 21
Max. ambient °C 40 40 40
temp.
Weight kg 7.6 12.5 18
Speed controller with 0-10V output. Com- Potentiometer 10kΩ. Combined flush or sur-
bined flush or surface mounting. face mounting.
For the manual control of speed and air flow For the manual control of speed and air flow
RADT 2V 4V 7V
of electrical fans with 0-10V input. The jet- of electrical fans with 0-10V output. The
Width mm 270 270 270
proof IP 54 enclosure is achieved with the jetproof IP 54 enclosure is achieved with
Hight mm 323 323 323 included surface mounting case. (Flush- the included surface mounting case. Flush-
Depth mm 163 163 163 mounting without the surface mounting mounting without the surface mounting
case,gives a splash proof IP 44 enclosure case, gives a splash proof IP 44 enclosure
also suitable for highly demand environ- also suitable for highly demand environ-
ments as bathrooms etc). ments as bathrooms etc.

MTV 1/010 MTP 10


Art. no. 30650 Art. no. 32731
Voltage supply V 230 V Voltage supply V DC 10
Output 0-10 V, Imax mA 8 Control signal kΩ 0...10
accessories
Electrical

Enclosure class IP 44 Working range V 0...10


Weight kg 0.2 Contact 1 NO
Switching capacity 4A/250V
Enclosure class IP 44
Weight kg 0.2

230 Vac 0-10 Vdc Us + -


1 2 3 4 5

Us = 10V Supply
+ = 0-10V Output signal
- = GND
360 | Electrical Accessories

MTP 20 For the manual control of speed and air Vdc V out
On/off, 3-step flow of electrical fans with 0-10V output. + - - +
The jetproof IP 54 enclosure is achieved
with the included surface mounting case.
(Flush-mounting without the surface 1 2 3 4
mounting case,gives a splash proof IP 44
3-step potentiometer for speed control with enclosure also suitable for highly demand
on/off function environments as bathrooms etc).
These control switches are to be used in MTP 20

0-10 V
GND
combination with motors/controls from

Vdc
Art. no. 310220
which the 10 V supply voltage is converted
Voltage supply V 10...15 DC
into three steps to obtain a minimum, mid EC MOTOR
Control signal kΩ 0...20
and maximum position.
Rangeability V 0...10
Position 1 and 2 can be adjusted to Red: Voltage output +10V max 1.1 mA
environmental requirements Enclosure class IP 44...54 Yellow: Control input 0-10Vdc
- Combined flush or surface mounting Weight kg 0,2 Blue: GND

R-DK4 KT (EX)
R-DK...KT(G)

T2 T1
12 11 14 N L L RT RT N L1 L2 L3 U V W

Manual five step transformer 1*

(400V) 250 V AC 230 V AC


max. 2 A max. 1 A
(With motor protection) for RVK 315Y4, 230 V AC
KTEX, DKEX and DVEX fans. An integral ther-
PE N L1 L2 L3
mistor releasing unit type U-EK230E with AT-
EX-approval can be used for the temperature 0 1 U V W PE
M
monitoring of motors in explosion protected 3 ~ 400 V 50/60 Hz 3~
range. A three-phase transformer which TP Y/
controls the fan speed by altering the sup- TP

ply voltage in five fixed steps. The steps are


adjusted manually, using the control knob on On/off 3~ motor with internal
SR171K13
the front of the unit. An integral motor pro- 27.11.2007 thermistors
tection device is included which cuts the sup-
ply voltage to the fan if the thermistor motor 1* If function is not needed, terminals must be bridged
protection triggs. The unit is reset by turning
the knob to “0” for 1 minute. Input terminals
for room thermostat RT cut supply voltage to
the fan when the circuit is broken.
NOTE! The transformer cannot be placed in
the EX zone.

R-DK4 KT
accessories

Art. no. 6051


Electrical

Voltage V 400 3~
Frequency Hz 50/60
Current A 4.0
Max. ambient temp. °C 40
Enclosure IP 21
WxHxD mm 270x323x163
Weight kg 11.5
Electrical Accessories | 361
NEW!

FRQ FRQ5 FRQ5 / + LED V2


Art. no.
4A
36229
10A
36230
Speed controller Speed controller Voltage V 208...480 208...480
with 0-10V input for with 5-step switch Phase ~ 3 3
3~ fan for 3~ fan Frequency Hz 50...60 50...60
• Optimized frequency • Optimized frequency Max. current A 4 10
inverters for the control inverters for the control Recom. fuse A 10 16
of one fan motor for frequency converter of one fan motor for frequency converter Ambient temp. °C 40 40
suitable isolation system and bearings suitable isolation system and bearings Hum, non cond. % 85 85
e.g. IE2 e.g. IE2
Enclosure IP 54 54
• Analog input for external speed setting • Integrated 5-Step switch
Weight kg 2.4 5.4
(0-10 V, 0-20 mA, PWM) • Step0=0Hz; Step1=10Hz; Step2=20Hz;
Width mm 240 250+2
• 10V DC output for external potentiometer Step3=30Hz; Step4=40Hz; Step5=50Hz
• Potential-free operation notification • Potential-free operation notification Height mm 284 302
• Enable contact section • Enable contact section Depth mm 132 212
• Motor protection by connecting thermo- • Motor protection by connecting thermo-
stats “TB” or thermistors “TP” stats “TB” or thermistors “TP” • Max. length of contoller (poti) cable 100m
• Interference emission EN 61000-6-3 • Interference emission EN 61000-6-3 • Max. length of motor cable 10m (screened)
• Interference immunity EN 61000-6-2 • Interference immunity EN 61000-6-2 Please note: Not suitable for external rotor
• Parallel operation of several motors is not • Parallel operation of several motors is not motors
allowed allowed When operating with Explosion proof fans the
• Max. length of contoller (poti) cable 100m FRQ has to be placed outside the EX zone!
• Max. length of motor cable 10m
(screened)
Please note: Not suitable for external rotor
motors Wiring diagram FRQ5 4/10A
When operating with Explosion proof fans
the FRQ has to be placed outside the EX
zone!

FRQ 4A V2 10A V2
Art. no. 36227 36228
Voltage V 208...480 208...480
Phase ~ 3 3
Frequency Hz 50/60 50/60
Max. current A 4 10
Recom. fuse A 10 16
Ambient temp. °C 40 40
Hum, non cond. % 85 85
Enclosure IP 54 54
Weight kg 2.3 5.3
Width mm 240 250
Height mm 284 302
Depth mm 115 195.5

Wiring diagram FRQ 4A/10A


accessories
Electrical
362 | Electrical Accessories

FRQ(5)S or integrated 5-Step switch Step0=0Hz;


Step1=10Hz; Step2=20Hz; Step3=30Hz; NEW!

Speed controller with Step4=40Hz; Step5=50Hz (FRQ5S)


FRQS 4A 10A
0-10V (or 5-step) • 10V DC output for external potentiometer
Art. no. 36231 36232
(FRQS)
Input for 3~ fan with Voltage V 208...480 208...480
• Potential-free operation notification
all pole sine filter • Enable contact section for a stand-by Phase ~ 3 3
The FRQS/FRQ5S frequency inverters have switch or electronic reset Frequency Hz 50...60 50...60
integrated all pole sine filters as standard. • Motor protection by connecting thermo- Max. current A 4 10
Therfore there is no need for shielded cables stats “TB” or thermistors “TP” Recom.fuse A 10 16
for the installation. This makes the unit also • Interference emission EN 61000-6-3 Ambient temp. °C 40 40
perfectly suited for retrofitting into exist- • Interference immunity EN 61000-6-2 Hum, non cond. % 85 85
ing systems. The sine filters enable existing • Complete range in IP54 Enclosure IP 54 54
non-shielded cables to be retained. This • Trouble free parallel operation of motors Weight kg 5.4 5.4
units also reliably controls motors which, due • No danger to the motors through voltage
Width mm 250+2 250+2
to their design, are not usually considered peaks, bearing current, etc.
suitable for frequency inverter operation i.e. Height mm 302 302
• No limit of motor cable length
external rotor motors. Depth mm 195.5 195.5
• Retrofit in installations with existent
wiring(unshielded cables)
• Save and trouble free motor operation • Operation without electromagnetic motor
with integrated, all pole effective sine noise NEW!
filter • Wide voltage range 3~ 208V-480V,
• Analog input for external speed setup FRQ5S+LED V2 4A 10A
50/60Hz
value (0-10 V, 0-20 mA, PWM) (FRQS) When operating with Explosion proof fans Art. no. 36233 36234
the FRQ has to be placed outside the EX Voltage V 208...480 208...480
zone! Phase ~ 3 3
Wiring diagram FRQ5S 4/10A Frequency Hz 50...60 50...60
Max. current A 4 10
Recom.fuse A 10 16
Ambient temp. °C 40 40
Hum, non cond. % 85 85
Enclosure IP 54 54
Weight kg 5.4 5.4
Width mm 250+2 250+2
Height mm 302 302
Depth mm 212 212

Wiring diagram FRQS 4/10A


accessories
Electrical
Electrical Accessories | 363

PKDM12
Thyristor power for setting set point, min. speed, max. speed PKDM12
unit (400V) and p-band. Digital input for on/off. Temper- Art. no. 11452
ature control possible. Several motors can
Stepless phase cut- Voltage V 208...415
be connected in parallel as long as the total
ting controller for Phase ~ 3
current does not exceed the current range.
3~400V/50Hz motors Frequency Hz 50/60
Fans to be used with this controller should
with motor protection. It Current A 12
be designed for thyristor speed control.
has a connection for a potentiometer or an Min. motor current A 0,2
external control signal 0...10V, 0...20mA or
NOTE: phase cutting controller can generate Output voltage appr. % 0...100
4...20mA. The control signal can be choosen
electronic noise! Max. power dissipation W 55
by an internal jumper. Internal potentiometer
Control signal 0...10V/4...20mA
Recom. fuse A FF30A 10x38mm
Ambient temperature °C 40
Enclosure class IP 54
Weight kg 3.4
WxHxD mm 270x323x163

Wiring diagram PKDM


Dcontrol PKDM
Switches
°C Jumpers
Depending on version switches or °C
V
jumpers for input signal
mA
E2 V
E2.1 E2.2
°C 24V DC OUT 1
Analog OUT 1

Analog IN 1

Analog IN 2
V
Digital IN 1

Digital IN 2
mA
Contact raiting J2
E1 mA
max. 5A/250VAC E1.1 E1.2

GND TK D1 A 24V E1 E2 D2

N L1 L2 L3 U V W 11 14 12 TK D1 GND 24V GND GND D2

K1 1* 1*

0 1 1 0

+ + 2 °C/bar > set U A + / °C/bar < set U A+


On/Off Output Input

0...10V TF.. 0...10V


PE N L1 L2 L3 (Imax=10mA) 4...20mA
TF..
Line U V W PE Temp.
3~ 208 .. 415 V M sensor
50/60 Hz 3~
bzw.
(3~ 208 .. 500V 50/60 Hz) Y or D TB 4-20mA
Special version TB
1 3
braun grün Pressure
3~ Motor
BN GN
sensor
MBG..
With internal Extern desired 10K
thermostats value +
Input
0...10V (Ri>100k)

1* If function is not needed, terminals must be


bridged
accessories
Electrical
364 | Electrical Accessories

PXDM
Multipurpose con- PXDM6A PXDM10A
troller for variable Art. no. 18620 18621
voltage 3~ fans Voltage V 208...415 208...415

Stepless phase cut- Phase ~ 3 3


ting controller for Frequency Hz 50/60 50/60
3~400V/50/60 Hz Current A 6 10
motors with motor protection. It has a con- Min. motor current A 0.2 0.5
nection for a potentiometer or an external Regulated output voltage approx. % 0...100 0...100
control signal 0...10V, 0...20mA or 4...20mA. Recommended fuse A FF20A 6x32mm FF20A 6x32mm
External Setpoint or external manual opera- Max. power dissipation W 30 50
tion is possible by 0 - 10 V (0 - 20 mA, 4 - Control signal 0...10V/4...20mA 0...10V/4...20mA
20 mA) signal at terminals “E2” and “GND”.
Perm. max. ambient temp. °C 40 40
“E2” configuration in base setup.
Perm. max. ambient humidity %RH 85 85
Enclosure class IP 54 54
Min. speed, max. speed and p-band settings
via software/display. Digital input for on/ Weight kg 2.9 3.4
off. Temperature/Pressure control possible. WxHxD mm 240x284x115 240x284x115
Several motors can be connected in parallel
as long as the total current does not exceed
the current range. Fans to be used with this
controller should be designed for thyristor
speed control.
NOTE: phase cutting controller can generate
electronic noise!

Wiring diagram PXDM

Ucontrol PXDM6...35(A)(Q)

J1
8
Kontaktbelastung USB
7
Contact rating TB/TP Digital Analog 24 V DC Analog Analog TF Digital
max. AC 250 V 2 A In In 1 Out 1 Out In 1 In 2 In 1/2 In 2

GND TB D1 A1 24V E1 E2 T D2
A B
N L1 L2 L3 U V W 11 14 12 21 24 22 TB D1 GND 24V GND GND T D2 24V GND (D+) (D-)

K1 K2

+ 1 + 2
Ausgang Eingang
Output Input
0...10 V 0...10 V
(Imax = 10 mA) 0...20 mA 24 V GND MODBUS
4 4...20 mA (RS-485)
PE N L1 L2 L3 + 1 6
Netz U V W PE TB TB Eingang
Line Input
3 ~ 208...415 V 50/60 Hz M 0...10 V
3~ 0...20 mA
1 q Y/Δ 4...20 mA A B
+ GND (D+) (D-)
5 KTY 81-210
accessories

(3 ~ 208...500 V 50/60 Hz) PT 1000


Sonderausführung Terminal
Electrical

Special version 3 ~ Motor TF.. TF.. AXG-1A(E)


mit eingebauten Thermostatschaltern
2
with internal thermostats
3

PDUN20K0
02.08.2011

1 Line 3 ~ 208...415 V, 50/60 Hz


2 Special version for line 3 ~ 208...500 V, 50/60 Hz
3 3~ Motor with internal thermostats
4 Output 0...10 V (Imax = 10 mA)
5 Input 1: 0...10 V, 0...20 mA, 4...20 mA, TF...(KTY)
6 Eingang 2: 0...10 V, 0...20 mA, 4...20 mA, TF...(KTY)
7 USB-interface
8 Contact rating max. AC 250 V 2 A
Electrical Accessories | 365

EC-Vent Fitness centre


control
board

• Built-in transformer (230V/24V)


• 24V supply to damper and sensors etc
• Can control two fans
• Can control heater/cooler

The EC-Vent is more than just a control for


EC fans. It is a tool that, together with EC
fans, simplifies demand-controlled ventila-
tion making it easy to set up and operate.
The unique feature of the EC-Vent is that Restaurant
it allows for a number of control options
with up to five sensors (analog or digital).
A single parameter such as temperature
can be controlled at several different loca-
tions. Alternatively, various parameters,
(CO2, humidity, temperature, etc.) can be
combined to control the fan directly or as a
complement to the weekly schedule and/or
the manual control to boost the ventilation
if needed. It can also be used to control a
heater or an extra fan via 0-10 V signal.
The EC-Vent consists of two units, one
central unit to be placed near the fan and a
single display unit normally sited in a room
easily accessible to the user. These units are
connected to each other with a low voltage
cable. The EC-Vent offers the opportunity
to connect up to 5 different sensors that Residential
simultaneously detect the actual ventilation
requirements and in this way the EC fan will
be steplessly controlled to ventilate exactly
as much as is needed, no more, no less. The
result is a good indoor air quality and the
user avoids high electricity bills.
The central unit for the EC-Vent can be
operated stand-alone from the room unit.

3018 - EC-Vent Room Unit is needed for


configuration!

CB
Art. no. 3115
accessories
Electrical

Voltage V 230
Phase ~ 1
Frequency Hz 50...60 Spa
Current A 6
Recommended fuse A 10
Supply to sensor, 24V DC mA 150
Ambient temp. °C -20...50
Enclosure class IP 44
Weight kg 0.95
366 | Electrical Accessories

EC-Vent unique feature of the EC-Vent is that it al- to connect up to 5 different sensors that
room unit lows for a number of control options with up
to five sensors (analog or digital). A single
simultaneously detect the actual ventilation
requirements and in this way the EC fan will
parameter such as temperature can be con- be steplessly controlled to ventilate exactly
trolled at several different locations. Alter- as much as is required, no more, no less. The
natively, various parameters, (CO2, humidity, result is a good indoor air quality and the
temperature, etc.) can be combined to con- user avoids high electricity bills.
• Ready for connection to CO2, moisture, trol the fan directly or as a complement to
temperature, presence and pressure sen- the weekly schedule and/or the manual con- 3115 EC-Vent Control Board is needed !
sors, etc. trol to boost the ventilation rate if required.
• Built-in humidity and temperature sensors It can also be used to control a heater or an RU
• User friendly menu extra fan via 0-10 V signal. Art. no. 3018
• Away mode and boost ventilation function The EC-Vent consists of two units, one Use for EC-Vent CB
central unit to be placed near the fan and a
Permitted range for °C 0...50
The EC-Vent is more than just a control for EC single display unit normally sited in a room
ambient temp.
fans. It is a tool that, together with EC fans, easily accessible to the user. These units are
Enclosure class IP 20
simplifies demand-controlled ventilation connected to each other with a low voltage
making it easy to set up and operate. The cable. The EC-Vent offers the opportunity Weight kg 0.3

Wiring EC-Vent

Room unit

Control board
accessories

DSG
Electrical

Pressure sensor DSG 200/500/1000


Brown
Voltage supply
A membrane-type sen- Art. no. 5169/5170/9466 Yellow Output 15...30V DC
sor for measuring the Voltage supply V 15V-30V DC/24V~± 15% 24V AC ±15%
White
differential pressure in Outp. 0-10 V, Imax mA 2
non-aggressive gases. Ambient temp. °C 0...50 Pressure connection ø5 mm
The difference in pressure
Current A 0.012
between the sensor’s
Press. range 200 Pa 0...200
plus (+) and minus (-) connections affects the
Press. range 500 Pa 0...500
membrane, which generates a voltage via a
differential transformer. This voltage converts Press. range 1000 Pa 0...1000
into a continuous DC voltage proportional to Enclosure IP 65
the membrane’s position. Cable length approx.
0.5 m.
Electrical Accessories | 367

Optigo OP 5
Multi purpose The controller is extremely easy to install OP5
and use. It is mainly intended for small appli-
controller cations. Optigo has a knob with an encoder
Art. no. 13891
Voltage V 24
which makes the menu system very easy to
Frequency Hz 50...60
use. You can read and set values shown in
• Temperature Power W 3
the back-lit display. A value is approved by
• CO2 pressing the knob. Optigo is suitable for DIN- Perm. max. amb. humidity %RH 90
• Pressure rail or cabinet mounting. Since the terminals Perm. ambient temp. °C 0...50
• Humidity are detachable all connections can be made Enclosure class IP 20
• Domestic hot water before Optigo is installed. WxHxD mm 122x120x64
Weight kg 0.215
Language independent, simple configu- Number of inputs/outputs OP5:
ration via the backlit display. Input for an
external set point device. Optigo 5 is a pre- 1 analogue input, PT1000
programmed, configurable controller for 1 SPI input for external set-point device
DIN-mounting that is intended to control 1 universal input, PT1000 or digital
temperature, CO2, pressure, humidity and 1 digital input
domestic hot water in HVAC applications. 2 analogue outputs, 0...10V DC

Optigo OP 10 which makes the menu system very easy to


use. You can read and set values shown in Art. no.
OP10
7282
Multi purpose the back-lit display. A value is approved by
Voltage V 24
pressing the knob. Optigo is suitable for DIN-
controller rail or cabinet mounting. Since the terminals
Frequency Hz 50...60
Power W 6
are detachable all connections can be made
before Optigo is installed. Perm. max. amb. humidity %RH 90
• Temperature OP10 is available in two versions, OP10 Perm. ambient temp. °C 0...50
• Domestic hot water with 24 V AC supply voltage and OP10-230 Enclosure class IP 20
with 230 V AC supply voltage. WxHxD mm 122x120x64
OP10 has 10 inputs/outputs and can be Weight kg 0.215
configured to control temperature (ven-
Number of inputs/outputs OP10:
tilation control with heating and cooling), OP10-230
water-heated radiator heating with outdoor AI 2 Art. no. 7283
temperature dependent control-curve or do- DI 2 Voltage supply V 230V AC
mestic hot-water control. Power consump. VA 4
UI 1
The controller is extremely easy to install
Perm. max. amb. humidity %RH 90
and use. It is mainly intended for small appli- AO 2
Perm. ambient temp. °C -40...+50
cations. Optigo has a knob with an encoder DO 3
Enclosure class IP 20
Weight kg 0.215
WxHxD mm 122x120x64

TG-R4/R5/ TG-KH/ TG-UH/PT1000


PT1000 PT1000 Outdoor sensor
accessories
Electrical

For measuring outdoor tempera-


Room sensor Duct sensor ture.
Room sensor with setpoint. Duct sensor for measuring air temperature in
For measuring room temperature, -R4 with ventilation ducts.
setpoint adjustment, -R5 without setpoint TG-UH/PT1000
adjustment. TG-KH/PT1000 Art. no. 35203
Art. no. 202705 Temperature range °C -40...+60
TG-R4/R5/PT1000 Temperature range °C -30...+70°C Enclosure class IP 65
Art. no. 31430 / 5404 Time constant 16 s WxHxD mm 70x93x46
Temperature range °C 0...50 Insert length mm 60...205
Control signal PT1000 Diameter mm 8
Enclosure class IP 30 Enclosure class IP 65
WxHxD mm 86x86x30
368 | Electrical Accessories

CO2RT Art. no.


CO2RT
13704
CO2RT-R-D
6993

CO2RT-R-D Voltage V 24 24
Frequency Hz 50/60 50...60
CO2-sensor for wall Power consumption W 3 3
mounting Working range ppm 0...2000 0...2000
CO2RT is a room sensor for measuring car- Accuracy - < ± (50 ppm +2% of measuring value
bon dioxide, CO2 concentration in indoor en- Circuit-breaking relay A - 1
vironments. Measuring range 0...2000ppm. Switching capacity - 50V AC / 60V DC
Output signal 0...10 V for the full measuring
Perm. range for ambient °C -5...+55 -5...+55
range. CO2RT also has a temperature sig- temperature
nal, 0...10 V DC for 0...50°C. Apart from the Perm. relative humidity, non % 90 0...90
above mentioned temperature signal CO2RT condensating
also has a PT1000 temperature sensor with Enclosure class IP 30 30
separate terminals CO2RT is intended for Weight kg 0.1 0.11
wall mounting.
Dimension WxHxD mm 85x100x30 85x100x30

CO2RT-R-D is a measuring system CO2-


sensor
The CO2-concentration is measured by
means of infrared light, a technique that
measures the absorption in gases. It has a
reference measuring system that compen-
sates values in relation to changes in light CO2RT CO2RT-R-D
intensity. The method gives several advan-
tages: 1 Supply voltage 24 V AC
1 Supply voltage 24 V AC
• Very high accuracy
• Exact identification of the detected gas 2 System neutral 24 V AC
2 System neutral 24 V AC
• Low risk for contamination
• Short response time 3 Output 0...10 V (humidity)
3 Common
• High long term stability
• Long calibration interval (>5 years) 4 Output 0...10 V (temperature)
4 Normally open

5 Output 0...10 V (CO2)


Display: The display models have an LCD- 5 Normally closed
display showing actual values in an alter-
nated series.
6 Signal neutral

7 Output, PT1000-sensor
Applications: Measuring the CO2-level gives
a direct indication about the indoor air qual- 8 Output, PT1000-sensor
ity. With this basic information ventilation
can be controlled with high precision and air
quality improved. At the same time supply NOTE! System neutral and signal neutral should be sepa-
rately wired because of current peaks in the supply wires.
air will only be increased when it is neces- Screw terminal: max. 1.5 mm². Output 3 (humidity) without
sary thus cutting energy costs. function.

IR24-P IR24-P
2Q2II,QSXW
Presence detector Art. no. 6995
A detector that gives a signal Voltage supply V 24 V AC/DC
accessories

when someone is present in the


Electrical

Ambient temperature °C -20...+50


room under supervision. The Max. ambient humidity %RH 95
detector has a pulse detect- Circuit-breaking relay A NC/NO
ing function that minimizes the risk for false Switching capacity 24V DC/0.2A
alarm. Settable output on/off delay. Intended Enclosure class IP 40
for wall or ceiling mounting.
WxHxD mm 66x112 x45
IR24-P is a presence detector designed for
automatic ventilation control of HVAC systems.
Power supply: 24V AC/DC (non-polarity)
NC-COM-NC: Change-over-contact for on/off
operation
Electrical Accessories | 369

CXE/AV
Universal regulator
CXE/AV
Regulator with multi-
function display constant
temperature or constant °C
pressure in duct systems V
with 0...10V output signal to control external 24 V DC Digital Analog Analog IN
mA Contact rating
E2 max. 5A/250VAC
devices (power units, frequency inverters, Out In 1/2/3 Out 1/2 0-10V...12
°C
EC-motors etc.). Two setpoints are possi- D+ 24V 24V D2 A1 GND E1 V
L1 N mA
ble. 3 digital inputs, 2 analogue inputs, 2 (+) (-)
PE D- GND D1 D3 A2 GND E2
E1
11 14 12 21 24 22

analogue outputs 0...10V and 2 relays with K1 K2

change-over contact. All in-/outputs are line


programmable. With preprogram modes also
for outdoor compensation for easy setup.
DATA
+ +
Menu languages are English, German, Swed- A B GND
RS485

ish,... 24VAC/Imax 70mA power supply for Output Input


0...10 V 0...10 V
sensors. (Imax = 10 mA) E2
A2

CXE/AVC + +
Output Input
Art. no. 30674

0...10 V 0...10 V
(Imax = 10 mA) E1
Voltage V 230 A1
Frequency Hz 50/60
Phase ~ 1
Output 0-10 V, Imax mA 10
Switching capacity 5A/250VAC
Ambient temp. °C 0...40
Enclosure class IP 54
Weight kg 0.9
Dimensions mm 166x160x87

Timer
function CXE/AVC Unicon CXE/AVC(E)

Regulator
(0...20 mA)..1

(0...20 mA)..2

GND
Analog Out 1

Analog Out 2

Contact rating
Digital In 1

Digital In 3

Digital In 5
Digital In 2

Digital In 4
0...10 V..1

0...10 V..2
4...20 mA

4...20 mA
Analog In

Analog In

Analog In

Analog In

Analog In

Analog In

max. AC 250 V 5 A D-
Universal module
TF..1

TF..2

D+

with timer function. 7 9 11 13 15 17 19 21 23 25 27 29 31 B

Controlled 0-10 V output e.g. for electronic PE N L1 1 2 3 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 A

K1 K2
speed controllers of fans.
Applications: Pressure control, outdoor +
Input 24 V DC 24 V DC
+
Eingang Data Data GND

temperature control, outdoor temperature PE N L1 TF..(KTY)


E1
Out Out Input
0...10 V
+ -
RS-485
Line E2
compensated pressure control, etc. 1 ~ 110...277 V
(208...415 V)
+ + +
Input Input Output D1 D2 D3 D4 D5
50/60 Hz
TF..(KTY) 4...20 mA 0...10 V
E2 (0...20 mA) (Imax = 10 mA)
CXE/AVC +
E2
+
A2

Art. no. 7579 Input


4...20 mA
Input
0...10 V
+
(0...20 mA) E1 Output
MCRE09K4
Voltage V 230 E1 0...10 V
(Imax = 10 mA)
22.04.2009

A1
Frequency Hz 50/60
Phase ~ 1
accessories
Electrical

Output 0-10 V, Imax mA 10


Enclosure class IP 54
Weight kg 1.3
Dimensions mm 213x185x102
370 | Electrical Accessories

RETP
Pressure/tempera- tact in the fan motor is activated. Regulated RETP 6/10
output voltage approx. 20-100%. Permitted
ture regulation, Art. no. 32293/32294
relative humidity, non condensating 85%.
single phase Voltage supply +24 V ±20%, Imax 250 mA.
Voltage V 230 1~
Frequency Hz 50-60
Thyristor-type stepless
pressure or temperature Current A 6/10
regulation (P-regula- Min. motor current A 0.2
tion) for single-phase motors with variable Output 0-10 V, Imax mA 10
voltage control. Used, for example, for room Recommended fuse A 16
temperature regulation where the heating is Max. power disspation W 10/40
conducted by air. An integral motor protec- Perm. ambient temp. °C 40
tion device is included which switch off the Enclosure class IP 54
supply voltage to the fan if the thermal con- WxHxD RETP 6 mm 223x200x131
WxHxD RETP 10 mm 240x284x132
Weight kg 1.3/2.3

Wiring RETP 6/10

...6 F1=M10 A / ...10 F1=FF20 A

RETP6/10

Auto
0
100 % °C mA V

E1

Contact rating

Analog Out 1

Analog In 1
max. AC 250 V 5 A

Didital In 1

PE PE N N L1 L1 U1 U1 U2 U2 11 12 14 TB TB D1 D1 A1 GND E1 GND 24V GND

K1

Input
0...10 V
PE N L1
PE U1 U2 TB TB 0...20 mA
4...20 mA
Line M TF..(KTY)
1 ~ 230 V 50/60 Hz 1~
q +

Output
0...10 V
1 ~ Motor
(Imax = 10 mA)
with internal thermostats
accessories
Electrical
Electrical Accessories | 371

REPT REPT 6/10


Art. no. 5698/5699
Digital voltage regu- which cuts the supply voltage to the fan if
Voltage V 230 1~
lation, single phase the thermal contact in the fan motor is ac-
tivated. Frequency Hz 50-60
Thyristor-type digital Radio interference suppression in accord- Current A 6/10
regulation for single- ance with EN 50081-1 and EN 50082-2. Min. motor current A 0.2
phase motors with variable voltage control. Regulated output voltage approx. 20-100%. Output 0-10 V, Imax mA 10
Used, for example, for the pressure regula- Permitted relative humidity, non condensat- Max. power disspation W 16
tion of fans in systems where there is a risk ing 85%. Voltage supply +24 V ±20%, Imax Perm. ambient temp. °C 0....40
of increased draught, and compensation is 70 mA. Enclosure class IP 54
required for outdoor temperature condi-
tions and other pressure conditions. An WxHxD REPT 6 mm 223x200x131
integral motor protection device is included WxHxD REPT 10 mm 240x284x132
Weight kg 2
Wiring REPT 6/10
...6 F1=M10 A / ...10 F1=FF20 A

REPT6/10

Auto
0
100 % °C mA V

6
E2 E1
Contact rating

Analog Out 1
max. AC 250 V 5 A

Analog In 1
Analog In 2
Digital In 2
Didital In 1
24V GND D+ D-

D3 D3 D1 D1 A3 GND
PE PE N N L1 L1 U1 U1 U2 U2 11 12 14 21 22 24 24V (TB) (TB) (E3) (GND) A1 GND (D2) (D2)
E2 GND E1 GND GND

K1 K2

+ 2
Input
24 V GND Data Data
0...10 V + -
0...20 mA RS-485
4...20 mA
TF..(KTY)
PE N L1 4
PE U1 U2 TB TB + + 1
Line M
Output Input
1 ~ 230 V 50/60 Hz 1~
q
0...10 V 0...10 V
1
(Imax = 10 mA) 0...20 mA
3 4...20 mA
1~motor with internal TF..(KTY)
thermostats 5

FXDM
Frequency inverter 2 analog inputs, 1 analog output 0..10V and ranges. Min. and max. speed limitations.
Frequency regula- 2 relays with change-over contact. All in-/
tor with multifunction outputs are programmable. Total motor pro- Integrated allpole sine filter for external rotor
display for constant tection using thermo contact / thermistor motors. Absolute parallel operation of fans,
temperature or constant connection. With preprogram modes also for no risk of damage for motor. Screened mo-
pressure in duct systems with integrated outdoor compensation for easy setup. Menu tor cables are not required!
accessories
Electrical

process controller (PID free programmable) languages are English, German, Swedish,...
or with 0..10V control signal. Two setpoints +24VAC / Imax 120mA power supply for Wiring diagram on page 372.
or manual mode is possible. 2 digital inputs, sensors. Making up to three settable speed

FXDM 5 8 14 18
Art. no. 31387 31388 31389 31390
Voltage V 208...480 208...480 208...480 208...480
Phase ~ 3 3 3 3
Frequency Hz 50/60 50/60 50/60 50/60
Max. current A 5 8 14 18
Recom. fuse max. A 10 10 16 20
Ambient temp. °C 40 40 40 40
Enclosure class IP 54 54 54 54
Weight kg 7.2 7.9 8.7 14.2
Width mm 250+2 250+2 250+2 280+2
Height mm 302 302 302 355
Depth mm 195.5 195.5 195.5 239
372 | Electrical Accessories

Wiring diagram FXDM

Fcontrol FXDM...(A)M

8 mA
Kontaktbelastung 7
Contact rating E1 E2
Adressierung
max. AC 250 V 2 A °C Addressing
TB/TP Digital Analog 24 V DC Analog Analog Digital Normal
In In 1 Out 1 Out In 1 In 2 In 2
A B
11 14 12 21 24 22 GND TB/ TB/ D1 D1 A GND 24V 24V E1 GND E2 GND D2 D2 24V GND (D+) (D-)
TP TP
K1 K2

L1 L2 L3 N U V W

+ + 2
24 V GND MODBUS
Ausgang Eingang (RS-485)
Output Input
≥ 10 mm² / 2x

0...10 V 0...10 V(PWM)


(Imax = 10 mA) 0...20 mA
4
4...20 mA
U V W PE TB TB TF..(KTY)

M + 1 6
PE L1 L2 L3 N 3~ Eingang
Netz q Y/Δ Input A B
+ GND (D+) (D-)
Line 0...10 V(PWM)
3 ~ 208...480 V 50/60 Hz 0...20 mA
4...20 mA Terminal
1 3 ~ Motor
TF..(KTY) AXG-1A(E)
mit eingebauten Thermostatschaltern
with internal thermostats 5
Nur in Sonderausführung
für IT-Netz geeignet! 3
Only in special version
suitable for IT network!
2

TFR
Room temperature TFR
sensor Art. no. 5158
With PTC element. With Temp. range of adjustment °C -20...+60
over-voltage protection Resistance at +20°C Ω 1900
(R20°C ca 1.9 kΩ). The Enclosure class IP 54
PTC element is supplied loose in the hous- WxHxD mm 75x75x37
ing. The element is fitted in one of the cable
conduits.

AWE-SK by closing an external contact connected to


the “Reset” connection block. The AWE-SK
Motor protection does not trip in the event of a mains power
accessories

Thermal contact motor pro- supply interruption.


Electrical

tection device for placing on The 14-11 connection block provides a


a control panel. The AWE-SK potential-free alarm contact producing an
is connected to the motor external signal when the relay is tripped.
relay control circuit.
AWE-SK
Function Art. no. 5138
If the thermal contact in the motor is tripped, Voltage V 0...230
the AWE-SK contact relay breaks the control Max. current A 2
circuit connecting with the motor, the warn- Ambient temperature °C 0...40
ing light illuminates and the fan stops. The
Enclosure class IP 20
motor will still be without current after the
Weight kg 0.15
thermal contact in the motor is closed. The
WxHxD mm 48x96x42
motor protector is reset by pressing the red
button marked “Reset” on the front panel, or
Electrical Accessories | 373

S-ET 10, STDT 16, MSEX


S-ET 10E STDT 16E Motor protection
Motor protection, 1~ Motor protection 3 ~
The S-ET 10 (for wall The STDT 16 (for wall
mounting) and S-ET 10E (for rail mounting) mounting) and the STDT
switches off the supply voltage to the mo- 16E (for rail mounting) switches off the sup- Protective motor
tor when the thermal contact in the motor ply voltage to the motor when the thermal switch intended for use in conjunction with
windings is tripped. The motor protector is contact in the motor windings is tripped. The EX 140 and EX 180 fans. The motor protec-
connected to a 230V supply and also to the motor protector is connected to a 400V sup- tor is set to the rated current of the con-
thermal contact in the motor. The motor pro- ply and also to the thermal contact in the nected fan. The motor protector is mounted
tector is reset by pressing the black button motor. on a rail, 356 mm wide.
as soon as the motor windings have cooled The motor protector is reset by press- An MSEX-H auxiliary contact for the motor
sufficiently. The motor protector can also be ing the black button as soon as the motor protector can be supplied, with an opening
used in conjunction with a transformer. The windings have cooled sufficiently. The motor and closing switch. This auxiliary contact is
S-ET has an alarm contact as an accessory. protector can also be used in conjunction fitted on to the front of the motor switch.
The alarm contact has a built-in potential- with a transformer. An alarm contact (K) is
free contact for an external signal to indicate available as an accessory. The alarm contact Enclosure MSEX-K is
when the contact relay has been tripped. has an integral potential-free contact pro- available as an accesso-
ducing an external signal when the relay has ry. This will fit both with
tripped. and without an auxiliary
S-ET 10 10E contact. The enclosure is for surface mount-
Art. no. 5154 5155 STDT 16 16E ing. Two output apertures at the top and
Voltage V 60...250 60...250 Art. no. 5152 5153 bottom.
Current range A 0.4...10 0.4...10 Voltage V 60...400 60...400
Phase ~ 3 3
The MSEX must not be placed in the EX
Ambient temp. °C -25...+40 -25...+55
zone!
Enclosure class IP 55 20 Current range A 10...16 10...16
Weight kg 0.45 0.2 Ambient temp. °C -25...+40 -25...+55 MSEX 0.25-0.4 0.4-0.63
Width mm 79 63 Enclosure class IP 55 20 Art. no. 5688 5689
Height mm 141 80 Weight kg 0.6 0.35 Max. power load kW 0.09 0.12
Depth mm 80 76 Width mm 80 54 Adjustm. range A 0.25...0.4 0.4…0.63
Height mm 150 80 Ambient temp. °C -25...+55 -25...+55
Depth mm 98 76 Enclosure IP 20 20

MSEX 0.63-1.0 1.0-1.6


Art. no. 5690 5368
Max. power load kW 0.25 0.57
Adjustm. range A 0.63-1 1…1.6
Ambient temp. °C -25...+55 -25...+55
Alarm contact must be ordered seperately! Enclosure IP 20 20

Alarm contact must be ordered seperately! MSEX 2.5-4.0


Line or controlled voltage Art. no. 5369
1 ~ 60...250 V 50/60 Hz
Max. power load kW 0.9
L1 N PE
Line or controlled voltage Adjustm. range A 2.5…4
3 ~ 60...500 V 50/60 Hz
L1 L2 L3 PE Ambient temp. °C -25...+55
max. 25 A
Enclosure IP 20
max. 80 A (Ue 415 V +5 %)
max. 63 A (Ue 440...500 V +6 %)

S-ET10E ZB * Single phase


accessories
Electrical
STDT... ZB *

1 3 5 24 12
1 5 24 12

I> I> I>

TB TB 2 4 6 23 11
I>

2 4 6 23 11 * = Option ZB
Contact rating of
auxiliary contacts

U V W PE
AC15 max.
M
U
Three phase
3~ 24 110 230 400 690
q
V
* = Option ZB TB I
A
6 4 4 2 1
TB
Contact rating of 3 ~ Motor
auxiliary contacts with internal thermostats
TB TB U1 U2 PE

M AC15 max.
1~ U 24 110 230 400 690
q V
I 6 4 4 2 1
A

1 ~ Motor
with internal thermostats
374 | Electrical Accessories

U-EK 230E EX Pulser Wiring of supply voltage and heater

Thermistor motor Temperature control


protection Electronic temperature control.
The Pulser is a single or two-
phase temperature regulator K 1 2 U 3 4 U K G G
for controlling heater batteries.
This device is connected in series be-
The U-EK 230E is a thermistor motor pro- tween the mains and an electric heater.
tection device which is intended for use in The Pulser has an integral regulator with an
conjunction with a contactor for the protec- input terminal for a duct temperature sensor
tion of the Ex fans, it can also be used for which is located in the supply air duct. Switch setting for internal set-point and sensor
fans with built-in thermistor. This is an elec- The integral sensor can be used when
tronic unit designed for snap fitting on to a regulating room temperature. The power
35 mm instrument rail. Fan motors have six regulation is completely stepless thanks to
series-connected thermistors, two per phase what is known as time-proportional control,
winding, whose resistance is determined which means that the relationship between
the ‘on’ and ‘off’ times is determined by the G G
by the motor temperature. When the motor
temperature exceeds the permitted limit, set temperature requirement. The total ‘on’
the resistance rises sharply and the motor and ‘off’ time, or pulse period, is approxi- Switch setting and wiring for internal set-point
protector is triggered. mately 1 minute. and external sensor
When the motor protector has been trig-
gered, the warning light marked “Störung”
Pulser
(“Fault”) is illuminated. The device is reset
Art. no. 5143
manually, either by pressing the “Reset” but-
ton, or by interrupting the voltage supply to Voltage V 230/400
the motor protector (stopping supply to A2) Frequency Hz 50 G G
for approximately 10 seconds. Phase ~ 1/2 TG-K3xx*
If a five-step transformer is used for regu- Current A 16
lating EX fans, the U-EK 230E should be con- Heating power W max 3600/6400
nected to the transformer. TG-G1xx*
Temp. range of adjustment °C 0...30 Switch setting and wiring for room control using
Temp. reduction at night °C 0...10 TG-R430 as sensor and set-point
A casing is available as an accessory. Ambient temperature °C 0...30
Ambient humidity %RH 0...90
Do not place the U-EK 230E in the EX zone!
Enclosure IP 20
G G
U-EK 230E EX Weight kg 0.32 TG-R430
Art. no. 30199 WxHxD mm 94x150x43
1
Voltage V 230 3
Frequency Hz 50
Max. current A 6 Switch setting and wiring using external separate
Switching capacity 250V AC/3A sensor and TG-R430 as set-point
Ambient temperature °C -20...+50
Enclosure class IP 20
Weight kg 0.1
G G TG-R430
WxHxD mm 35x116x58 TG-K330
2
3

Wiring of night set-back function


accessories
Electrical

°C

K K

*Various temp. ranges available, for example


TG-G150 = 20...50°C, TG-K370 = 40...70°C etc.
Electrical Accessories | 375

Pulser M TTC
Temperature control Temperature control mode to suit the dynamics of the controlled
object.
Electronic temperature control. TTC-2000 is a 3-phase triac
The Pulser M is a single or controller for controlling elec-
Supply air temperature control
two-phase temperature regu- tric heating up to 25 A. It is
For rapid temperature changes, TTC-2000
lator for controlling heater batteries. made for wall mounting. TTC-2000 is to be
will work as a PI-controller with a fixed pro-
This device is connected in series between connected in series between power supply
portional band of 20K and a fixed reset time
the mains and an electric heater. The Pulser and an electric heater and can control both
of 6 minutes.
M has an integral regulator with input termi- Y- and Delta- connected loads. TTC-2000
nals for a main sensor together with min. or can control assymetrical Delta-loads.
Room temperature control
max. limit sensors. The integral sensor can
For slow temperature changes, TTC-2000
be used when regulating room temperature. Function
will work as a P-controller with a fixed pro-
The power regulation is completely stepless The controller pulses the entire power out-
portional band of 1.5 K. When running room
thanks to what is known as time-proportion- put ON/OFF and utilises time-proportional
temperature control the supply air tem-
al control, which means that the relationship control, the ratio between On-time and Off-
perature can be maximum and/or minimum
between the ‘on’ and ‘off’ times is deter- time is varied to fit the prevailing heating
limited.
mined by the set temperature requirement. requirement. E.g. ON = 30 sec and OFF= 30
The total ‘on’ and ‘off’ time, or pulse period, sec gives 50% output power. The cycle-time
Controlling larger electric heaters
is approximately 1 minute. (the sum of on-time and off-time) is adjust-
At larger loads TTC-2000 can be combined
able 6...120 sec.
with ancillary control board TT-S1 (p. 376).
TTC-2000 automatically adapts control
Pulser M
Art. no. 5144 TTC
Voltage V 230/400 Art. no. 5171
Frequency Hz 50/60 Voltage V 230/400 3~
Phase ~ 1/2 Frequency Hz 50
Current A 16 Current A 25
Heating power W max 3600/6400 Max heating power kW 10/17
Temp. range of adjustment °C 0...30 Temp. range of adjustment °C 0...30
Temp. reduction at night °C 0...10 Temp. reduction at night °C 0...10
Ambient temperature °C 0...30 Ambient temperature °C 0....40
Ambient humidity %RH 0...90 Enclosure IP 30
Enclosure IP 20 WxHxD mm 160x207x94
WxHxD mm 94x150x43 Weight kg 1.8
Weight kg 0.32

Circuit diagram for supply voltage and position


of change-over switch with external
sensor. See Pulser.

Adjustment of change-over switch with min.


limit sensor.

accessories
Electrical

Adjustment of change-over switch with max.


limit sensor.
376 | Electrical Accessories

TT-S1 TT-S4/D AQUA 24TF


Control board Step switching Temperature controller
TT-S1 is a control unit AQUA 24TF with room or
board for use when Step controller for supply air temperature con-
you need to control DIN-rail mounting trol. The AQUA 24TF controls
larger loads with a TTC-2000. TT-S1 is used in a cabinet or other enclosure. The control- three-point actuators with
to control a contactor that activates and ler is intended for controlling electric heating a pulse-pause signal where
deactivates a basic heating load. For best batteries, 4 relay output. The step controller the ratio between on-time and off-time is
function the load connected to TT-S1 should can be set to sequence or binary mode. Can proportional to the temperature offset. The
be of equal size to the load connected to the be used together with any controller with controller has a built-in and external sensor
TTC-2000. TT-S1 and TTC-2000 must have 0...10 V output signal. The switch setting on which can be connected. Use surface sensor
separate loads. the front of the controller determines the TG-A 130 when frost protection or shut-
number of steps to be used. The input sig- down function is required. AQUA 24TF is
Easy to install nal 0...10 V is divided up into the number of suitable for control of valve actuator RVAZ4
The TTC-2000 is prepared to plug-in the steps, thus setting the switch-on point for 24.
TT-S1 module. TTC-2000 detects if a TT-S1 each step. Cascade factor (CF) must be set to 1 for
is installed and automatically adapts the single sensor control. Minimum limit (Min)
control function accordingly. No settings are TT-S4/D not active in single sensor control.
necessary. Connect in series with the control Art. no. 9154
voltage for the heating load contactor. The Voltage supply V 24 VAC Parameter Unit Value
supply should be wired via the fan stat, the
Voltage V Out signal max 250V AC, 2A Art. no. 5136
high temperature limit switch etc. TTC-2000
Regulating ratio Outgoing 4 sequence steps Voltage supply V 24V AC +/-
and TT-S1 must have separate, equal-sized
Working range 15 binary steps 10%
loads.
Enclosure class IP 20 Frequency Hz 50/60
TT-S1 WxHxD mm 101x85x74 Power consumption Max 5 VA
Art. no. 5173 Permitted range for ambient °C 0...50
temperature
Voltage supply V Suppl. by TTC-2000
Permitted relative humidity, % 90
Control signal Suppl. by TTC-2000 TTC25 TT-S4/D non condensating
Contact max. 250V/2A TTC40F 7 13
Temperature range of °C 0...30
Max. heating power* kW 34 8 19 adjustment
9 21
*together with TTC-2000 Cascade factor (CF) 1...15
Enclosure class IP 20
Fig 1 Weight kg 0.2
WxHxD mm 92x150x45

1 Alarm relay 1
+ 2 2 A 240 V AC
0 - 10V DC in TT-S4/D
0
13 3
8 15 Alarm relay 2
4
1 2 9 19 2 A 24 V AC
5
TT-S1 TTC25X 21
6 Sensor neutral
TTC40FX 7 Main sensor
8 Sensor neutral
Fig 2 9 Limiting sensor
10 Sensor neutral
11 Frost protection sensor
12 Night setback
13 Supply voltage 24 V AC
14 System neutral
accessories

15
Electrical

Run mode indication


16 Run mode indication
17 Actuator, Common pole
18 Actuator, Increase heat
19 Actuator, Reduce heat
Electrical Accessories | 377

RVAZ4-24 TG-A 130 RT 0-30


Surface sensor Room thermostat
RVAZ4-24A Surface sensor TG-A The RT 0-30 is an elec-
Valve actuator 130 to be used to- tronic room thermostat for
RVAZ4 24A is a valve actu- gether with AQUA indoor wall mounting, with
ator for 0...10 V DC control 230T or AQUA 24TF a change-over relay for regulating either
signal. 24 V AC supply voltage. Suitable for when frost protection heating or cooling. It has an integral sensor,
controlling ZTV/ZTR valves, kvs <= 6.0. or shut down function is required. Can not be but an external sensor such as the TG-K330
This product conforms with the EMC used together with the PULSER series. or TG-R630 can also be connected to the
requirements of European harmonised thermostat. The RT 0-30 can also be used
standards EN60730-1:2000 and EN60730- TG-A130 with other external temperature sensors to
2-8:2002 and carries the CE mark. Art. no. 5159 achieve different temperature range.
Length mm 1500
RVAZ4-24/24A
Temp. range of adjustment °C 0...30 RT 0-30
Art. no. 9798/9862
Enclosure IP 65 Art. no. 5151
Voltage supply V 24 V AC +/-
Voltage V 230
15%
Phase ~ 1
Power consumption W max. 6
Frequency Hz 50/60
Frequency Hz 50/60
Temp. range of adjustment °C 0...30
Max. stroke
Full stroke time
mm 5.5
121 sec
TG-D130 Enclosure class IP 30
Power consumption W 1
Stem force Nm 400 Immersion sensor
Perm. ambient temp. °C 0...50
Max. ambient humidity %RH 95 This temperature sen- Perm. max. ambient humidity %RH 90
Ambient temperature °C 0...50 sor is for measuring
Circuit-breaking relay A 16, 250 VAC
Enclosure class IP 44 the water temperature
WxHxD mm 86x86x30
in hot water batteries
VBR and VBK. It can be used for frostprotec-
tion.
TG-R600/630 TG-D130
External sensor Art. no. 13941
For sensor measurement in Temperature range °C 0...30
applications where a sen- Material stainless steel
sor with a higher enclosure Pressure rating PN10
rating is required. To be used with the TTC Enclosure IP IP 65
2000, Pulser or RT 0-30.

TG-R600 TG-R630
Art. no. 5174 5164
Temp. of adjustment °C -30...+30 0...30
Enclosure class
WxHxD
IP 65
mm 85x90x35 85x90x35
65
TG-R430/530
Room sensor for wall
mounting

TG-K330 TG-R430 room sensor with


adjustment of desired value.
External sensor

Duct sensor The dial can be locked with


External sensor
a screw which is concealed behind the cover.
Duct sensor which
The TG-R530 is a room sensor for measuring
is mounted inside the duct, with a sensor Internal sensor
the room temperature. To be used with the
accessories
Electrical

diameter of 9 mm, a circular flange ø 40 mm


TTC, Pulser or RT 0-30.
and adjustable length from 15 to 130 mm.
The connecting cable is 1.5 m. To be used
with the TTC, Pulser or RT 0-30. TG-R 430/530
Art. no. 5162/5163
TG-K 330 350 360 Temp. range of adjustment °C 0...30
Art. no. 5160 5161 4846 Enclosure class IP 30
Temp. range °C 0...30 20...50 0...60 WxHxD mm 86x86x30
Enclosure IP 20 20 20
378 | Electrical Accessories

TM 10 HR1 T 120
Mechanical thermo- Room humidistat Timer
stat A humidistat for controlling Timer with 120-min-
Mechanical thermostat exhaust air fans in response utes operating time.
with change contact to to the relative humidity. The Supplied with flange
switch fans or for the humidistat uses human hair for fitting into equip-
connection to controllers with thermostat or as the humidity sensor me- ment housing. Casing
release connection. The setpoint is at the ro- dium. The set-point can be anywhere be- for surface mounting is
tary button from 0 to 40°C adjustable. tween 10 and 95% RH. Base plate in black Frame for available as an extra. A
plastic and cover in white plastic. wallmounting switch for closing and
TM 10 The HR1 is supplied with a sliding cover breaking circuits. A link
Art. no. 2703 over the set-point dial, which can be locked. can be used to produce a change-over func-
Temp. range °C 0...40 The humidistat should be mounted in a lo- tion. The timer makes a quiet ticking sound
Ambient temp. °C -20...+50 cation with good air circulation and constant when connected.
Differential 1.5K temperature and humidity. It should not be
Contact 1 change-over fitted on external walls, walls in direct sun- This timer is suitable for controlling the REU
Switching capacity 250V/max 4A light, corners etc. and RTRDU five step transformers.
The humidistat’s mounting holes make it
Enclosure class 54 IP
suitable for fixing on to a terminal box with T 120
Weight kg 0.35
screws at 60 mm centres. Art. no. 5165
WxHxD mm 86 (+27)x126x58 (+13)
The humidistat should be precision- Voltage V 230
calibrated after it has been mounted, and
Frequency Hz 50
should be recalibrated regularly. Dust and
Max. current load A 10 (2)
other matter should be removed with a soft
brush at regular intervals. Connection time min 0...120
Contacts 1 and 3 close when the air hu- WxHxD mm 80x80x25
midity exceeds the preset value.
Sensor
HR1
Art. no. 5150
3 2 1 Setpoint %RH 10...95
Differential %RH 4% at 45
Heating
Cooling

Switching capacity 250V/5A


Max. operating temp. °C 40
L Enclosure class IP 21
N Weight kg 0.16
PE
WxHxD mm 83x136x37

DTV
Pressure switch
Differential pressure
switch for air and non-
Trafo 15/D
corrosive gasses.Relay Transformer 230/24
contact data 250 V AC 5 A, The transformer mounted
change-over. in a 3-module casing for
DIN-mounting in a cabinet
DTV 200 500 or other tight enclosure.
accessories

Art. no. 6261 5044


Electrical

Pressure range Pa 20...300 50…500 Trafo 15/D


Media Clean air Clean air Art. no. 13223
Air temperature °C -20...+85 -20...+85 Voltage supply V 230 AC
Switch. diff. press. Pa 15Pa +/-5 25Pa +/-8 Voltage output V 24 AC
Max. current load A 250V, 5A (0.8A) Enclosure class IP 20
Enclosure class IP 54 54 Power output VA 15
WxHxD mm 88x81x60 88x81x60 WxHxD mm 53x85x74

DTV
1
2
3
Electrical Accessories | 379

MicroREX D21 SC1/D SC2/D


Time switch Threshold module Step controller
The MicroREX D21 is a digital 1 step DX cooling
7 day time switch with a cir- SC1/D is a one-stage signal Step controller suitable for
cular segmented display for converter which converts heating/cooling or alarm
general rail mounting use or a 0...10V DC input signal to a change-over applications. Converts 0...10 V input signal
on walls in a box, included. relay function with adjustable switching to relay output. The module is suitable for
Up to 8 program pictures can points. SC1/D can be set for direct or re- mounting on a DIN-rail in a cabinet or other
be set. A program picture incorporates both verse action, i.e. relay activation on rising enclosure and has adjustable switching
ON and OFF time. If no button is pressed for input voltage or relay activation on falling points. SC2/D can be set for either binary or
60 seconds during programming the time input voltage. sequential control. Voltage supply 24 V AC
switch goes back to the start position. +/- 15%, 24 V DC (18...35 V DC).
The copying function enables program to SC1/D
be copied to other days. Minimum switching Art. no. 13217 SC2/D
time is 1 minute. The switching times are pro- Voltage supply V 24 VAC Art. no. 13616
tected but can be overlaid by other programs.
Frequency Hz 50/60 Frequency Hz 50/60
Programs are displayed with a minimum seg-
Power consumption 2 VA Power consumption 2 VA
ment size of 30 minutes. The time and the
Control signal 0...10 V Perm. ambient temp. °C 0...50
week days are presented digitally. The sum-
mer-/winter changeover can be programmed Circuit-breaking relay A 230V AC, max. 10 Max. ambient humidity %RH 90
for hand or automatic operation. Plastic hous- Max. ambient humidity %RH 90 Step distance 0...2 V
ing for easy wall mounting, is available. Ambient temp. °C 0...50 Enclosure class IP 20
Enclosure class IP 20 WxHxD mm 53x85x74
MicroREX WxHxD mm 53x85x74
Art. no. 9800
Voltage V 230
1 Sys.neutral Supply- 1 R1
Frequency Hz 50/60 10A 230V ~
2 24V AC in voltage 2
Max. current load A 16
3 Not connected 3 Not connected
Accuracy ±1s/day
4 4 Not connected
WxHxD mm 36x83x66 Relay
5 5 R2
6 230V AC, 10A 6 10A 230V ~
7 Signal neutral 7 Input signal 0-10V DC
8 Input signal 0-10 V DC 8 Signal neutral
9 Not connected 9 Not connected
10 Not connected 10 Not connected
11 Not connected 11 Sys.neutral Supply
12 Not connected 12 24V ~ in voltage

K-WFR Art. no.


K-WFR
2647
2 4
Air flow switch, Contact 1 change-over
accessories
Electrical

mechanical Switching capacity AC 24...230V, 15(8)A


For the supervision of Working range 1(2)...8(9,2) m/s
air flows caused by Differential ≥1 m/s
electric heating spirals and of air flows in Permitted range for °C -40...+85
channels or conduits or in additional air and ambient temperature
exhaust air fans or devices. Max. temp. of trans- °C 85
ported air 1
Enclosure IP 65 1 = Red
Weight kg 0.5 2 = White
4 = Blue
380 | Electrical Accessories

K-FST1 K-LSW230 REV


Frost protection Flow meter, 0,2...8 ON-OFF
thermostat m/s, electronic REV-Isolator mounted
Especially suited to ensure The flow meter for duct on a bracket, leads
the protection of hot water installation controls the connected l max 20 A.
coil heating systems against freez- air-flow velocities over a rage of 0,2...8 m/s
ing. The frost protection thermo- in accordance with the calorimetric princi- - 3POL/03 (art. no. 33978)
stat models are equipped with two ple. The relay functions are displayed using 3-pole (closing/auxillary contact 1) lead
switching outputs that provide the option LED. It possesses a start-up delay of approx. 3x1.5 mm2 for 1 phase motor TK not lead out.
to act on the system already in advance of 120s
the attaining of the corresponding danger - 5POL/05 (art. no. 33979)
K-LSW230 5-pole (closing/auxillary contact 1) lead
point. All devices are fail-safe and dispose
of a lead-sealable set value setting facility. Art. no. 2638 5x1.5 mm2 for 1 phase motors TK lead out
In each case, the capillary tubes are active Voltage supply V 230V 50/60Hz and 3 phase motors TK not lead out.
over their entire length. Capillar length: 6.0 Working range 0,2...8m/s
M. capillar is active on the whole length. Contact 1 change-over - 5POL/07 (art. no. 33980)
The device responds if the adjusted scale Switching capacity 250VAC / 5A 5-pole (closing/auxillary contact 1) lead
value is attained over a length of approx. 30 7x1.5 mm2 for 3 phase motors TK lead out.
Power consumption >3VA
cm 60 cm respectively. Specially suited for Permitted range for °C -20...+60
the measuring of temperatures in non-ag- - 9POL/12 (art. no. 33981)
ambient temperature
gressive gases. The bracing of the capillary 9-pole (closing/auxillary contact 1) lead
Permitted max. ambient %RH 85 12x1.5 mm² for 3 phase motors TK lead out
tubes in front of the coil heating system can
humidity and two speed (D/Y).
be realised by means of installation clips.
Enclosure IP 65 (Sensor IP20)
K-FST1 Width mm 82 When operating with Explosion proof fans
Art. no. 2636 Height mm 80 the REV has to be placed outside the EX
Contact 1 change-over Depth mm 57 zone!
Curcuit-breaking A 15(8)A, 24-250V~ Probe length mm 138
Temp. range of adjustm. °C -10...+12
Max. temp. of transp. air °C 200 Version with
Ambient temperature
Enclosure class
°C -10...+55
IP 40
(L- L+)
L N 14 12 11
remanence relay REV incl.
WxHxD mm 105x112x55 EMC KIT
Line
L N 14 11 12 The EMC-KIT is an
accessory for the
1 = Red 2 4 Line
REV ON-OFF isola-
2 = White tor. Due to IE2/ecodesign directive the use
4 = Blue of frequency converters will increase. For
Streaming > set value contact 11-14 closed
frequency converters without all pole sine
Streaming < set value contact 11-12 closed filter a shielded connection is needed. We
(after this time expires)
recommend to order the EMC-KIT mounted.

REV- Isolator with EMC-KIT is pre-wired,


l max 20 A.
1 5POL/05 (art. no. 34549)
EX 5-pole (closing/auxillary contact 1)
connection The complete set consist of:
box • REV-Isolator with mounting bracket
The EX-connection box is of dark • EMC-Panel for EMC conformity
accessories

• EMC-clamp for easy connection of the


Electrical

grey, glass fiber polyester resin


and will be delivered with 3 ca- shielded cable
ble glands and 1 stopping plug in • Terminal box for PTC connection
Ex-execution. There are 8 clamps • Terminal strip 2,5mm² for PTC connection
in the connection box. • Shielded cable 4G 1,5 for supply connec-
tion
• Cable 2x0,75 for PTC connection
EX connection box
Art. no. 2704 When operating with Explosion proof fans
Explosion proof Ex II 2G EX e II T6 the REV has to be placed outside the EX
Certificate PTB 99 ATEX 3103 zone!
Voltage V 690
Max. current A 32
Enclosure, motor IP 66
Ambient temperature °C -50...+55
WxHxD mm 115x115x64
Electrical Accessories | 381

REV ATEX S-DT2 SKT S5S 100T1


Explosion proof
ON-OFF isolator S-DT2 DKT S5S 100T3
Five step switch
(Art. no. 36414)
S-DT2 GKT Five step switch for trans-
• 25A, 3pole 1 x NC and 1 x NO Two speed switch former TES. Imax=10A. To
• Polyester resin (RAL 7024) Switching and protecting unit star/trian- mount in a front door of a
• Padlockable in the "Off" position (3x) gle/Dahlander/2 separated windings. For switch board.
• Sealing to IP66 changing speed of three phase motors with Contacts:
2 speed. Automatic cut out of motor when 5 steps NO
Safety switches ensure the obligatory iso- thermal contact trip (overheating of motor). 1 auxiliary contact NO
lation of electrical power during cleaning, Reset by setting the main switch to 0 and 1 auxiliary contact NO (impulse)
maintenance and repair of the equipment. restart. S5S 100 T1 T3
With tapped hole 2xM25, 1xM20. Plastic casing for surface mounting, as- Art. no. 2700 2701
Suitable cable glands are available as acces- sembly without casing is possible on a
Voltage V 230 400
sories. mounting rail.
Phase ~ 1 3
S-DT2 SKT DKT GKT
Max. current A 10 10
Art. no. 2697 2698 2699
Weight kg 0.15 0.15
Voltage V 400 400 400
Width mm 48 48
Phase ~ 3 3 3
Height mm 48 48
Max. power load kW 4 4 4
Depth mm 103 128
Connection Y/D Y/YY Y/Y
Enclosure class IP 54 54 54 S5S 100T1
WxHxD mm 166x230x129

S2S 160
Two speed switch
This two speed switch
is available with cas-
ing for surface mounting:
1~change between two
speeds with changing the different wind-
ings (auxiliary and main windings). Casing, S5S 100T3
plastic.
NOTE! Only for motors with wiring
diagram no 20.

S2S 160
Art. no. 2693
Voltage V 1-230
Current A 10
Enclosure class IP 54

TES / TDS TES


Art. no.
022A5
9511
030A5
9512
040A5
9513
050A5
9524
070A5
9514
100A5
9515
Speed controler Voltage V 230 230 230 230 230 230
for switchboard
accessories
Electrical

Max. current A 2,2 3 4 5 7 10


assembly Ambient temperature °C 40 40 40 40 40 40
Transformers according
Weight kg 2,4 2,9 3,6 3,5 5,1 6,8
VDE 0550, Insulation class B.
Width mm 96 96 120 100 120 120
For 3~ systems the TDS consists of two
transformers, switched in save / V-circuit. Height mm 100 100 118 112 118 118
They have 5 voltage sections. Depth mm 78 88 86 95 99 119
400 / 240 / 190 / 145 / 95V (TDS) TDS 010A5 030A5 040A5 050A5 070A5 110A5
230 / 160 / 130 / 105 / 80V (TES)
Art. no. 9516 9517 9518 9519 9520 9521
Voltage V 400 400 400 400 400 400
Max. current A 1 3 4 5 7 11
Ambient temperature °C 40 40 40 40 40 40
Weight kg (2x) 2,9 (2x) 3,5 (2x) 5,3 (2x) 6,8 (2x) 8,6 (2x) 11,6
Width mm (2x) 96 (2x) 120 (2x) 120 (2x) 120 (2x) 150 (2x) 150
Height mm (2x) 100 (2x) 118 (2x) 118 (2x) 118 (2x) 145 (2x) 145
Depth mm (2x) 88 (2x) 86 (2x) 99 (2x) 119 (2x) 118 (2x) 145
382 | Electrical Accessories

SM 230A Art. no.


SM 230A
30190
SM 24A
9344
SM 230A-SR
4920
SM 24A-SR
9351
Damper actuator Voltage V 100...240 24 100...240 24
The damper motor Frequency Hz 50/60 50/60 50/60 50/60
is made for the ad- Power consumption W 2,5 4 2,5 2
justment of damp- Enclosure class IP 54 54 54 54
ers. The motor is for round and corner shafts
Full stroke time s 150 150 150 150
10...20 mm. 1-wire-control (open/close) or
For ambient temperature °C -30...+50 -30...+50 -30...+50 -30...+50
3-point-control. Control signal 0...10V for
A-SR versions. Direction of rotation revers- Weight kg 1.05 1 1.05 1.15
ible. Manual override with push-button. The
max. torque is 20Nm for dampers up to 4
m2 and a max. angle of rotation of 95° with
adjustable mechanical limitation.

SM 230A / SM 24A SM 230A-SR SM 24A-SR


T ~
N L SG..24
T
N L1 N L1 – +
Y DC 0…10 V Y DC 0 … 10 V
0 U5 DC 2…10 V U DC 2 … 10 V

1 2 3 1 2 3 1 2 1 2 3 5
1 2 3 5
0 0
1 1

SF 230A SF 230A SF 24A SF 24A-SR SF 24A-S2

SF 24A Art. no.


Voltage V 230
33690 33691
24
33692
24
33693
24
SF 24A-SR Frequency Hz 50/60 50/60 50/60 50/60

SF 24A-S2 Power consumption


Torque
W 6.5
Nm 20
5
20
5
20
5
20
Damper actuator Full stroke time 75s/20s 75s/20s 150s/20s 75s/20s
• For air dampers up to approx. 4 m2 Enclosure class IP 54 54 54 54
• Torque 20 Nm Ambient temp. °C -30...+50 -30...+50 -30...+50 -30...+50
• Nominal voltage AC 230 V (SF 230A); AC/ Weight kg 2.1 2.1 2.1 2.3
DC 24 V (SF24A / SF24A-SR / SF24A-S2);
• Control: Open-close; modulating DC
0...10V (SF24A-SR)

Spring return actuator with emergency func-


tion for adjusting air dampers in ventilation
and air conditioning systems in buildings.

SF 230A, SF 24A SF 24A-SR SF 24A-S2


accessories
Electrical

T ~ T ~ 1 = black S3 = white
– + – + 2 = red S4 = orange
S1 = purple S5 = pink
Y Y 1 DC 0 … 10 V S2 = red S6 = grey
U U DC 2 … 10 V

1 = black S1 S2 S3 S4 S5 S6
1 2
2 = red
1 = black 1 2 3 5 3 = white
2 = red
5 = orange <A <B
A = 10% B = 10 ... 90%
>A >B
Electrical Accessories | 383

AES
Exhaust air and smoke extraction Exhaust air and smoke extraction switchgear
switchgear AES...D = direct switching
AES...SD = star-delta-switching
For fans with three-phase motors. Up to AES...SS = 2-steps with switching for separate windings
four fans can be controlled depending on AES...DA = 2-steps with switching for tapped windings
type. All functions in accordance with VDMA
24177 (fans for keeping buildings free of
smoke and heat in case of fire). Complete
switchgear implemented in accordance with
DIN/VDE 0660. In plastic housing.

AES...D Art. no. kW Amount of controlled Motor protection current-range * Dimensions


motors
1-step L/B/H [mm]
AES-0.37kW-D 35619 0.37 1 0.6 to 1 A 320/240/130
AES-0.37kW-D2M 35620 0.37 2 0.6 to 1 A 400/320/130
AES-0.37kW-D3M 35621 0.37 3 0.6 to 1 A 480/400/130
AES-0.37kW-D4M 35622 0.37 4 0.6 to 1 A 480/400/130
AES-0.55kW-D 35623 0.55 1 1 to 1.6 A 320/240/130
AES-0.55kW-D2M 35624 0.55 2 1 to 1.6 A 400/320/130
AES-0.55kW-D3M 35625 0.55 3 1 to 1.6 A 480/400/130
AES-0.55kW-D4M 35626 0.55 4 1 to 1.6 A 480/400/130
AES-0.75kW-D 35627 0.75 1 1.6 to 2.4 A 320/240/130
AES-0.75kW-D2M 35628 0.75 2 1.6 to 2.4 A 400/320/130
AES-0.75kW-D3M 35629 0.75 3 1.6 to 2.4 A 480/400/130
AES-0.75kW-D4M 35630 0.75 4 1.6 to 2.4 A 480/400/130
AES-1.1kW-D 35631 1.1 1 2.4 to 4 A 320/240/130
AES-1.1kW-D2M 35632 1.1 2 2.4 to 4 A 400/320/130
AES-1.1kW-D3M 35633 1.1 3 2.4 to 4 A 480/400/130
AES-1.1kW-D4M 35634 1.1 4 2.4 to 4 A 480/400/130
AES-1.5kW-D 35635 1.5 1 2.4 to 4 A 320/240/130
AES-1.5kW-D2M 35636 1.5 2 2.4 to 4 A 400/320/130
AES-1.5kW-D3M 35637 1.5 3 2.4 to 4 A 480/400/130
AES-1.5kW-D4M 35638 1.5 4 2.4 to 4 A 480/400/130
AES-2.2kW-D 35639 2.2 1 4 to 6 A 320/240/130
AES-2.2kW-D2M 35640 2.2 2 4 to 6 A 400/320/130
AES-2.2kW-D3M 35641 2.2 3 4 to 6 A 480/400/130
AES-2.2kW-D4M 35642 2.2 4 4 to 6 A 480/400/130
AES-3kW-D 35643 3.0 1 4 to 6 A 320/240/130
AES-3kW-D2M 35644 3.0 2 4 to 6 A 400/320/130
AES-3kW-D3M 35645 3.0 3 4 to 6 A 480/400/130
AES-3kW-D4M 35646 3.0 4 4 to 6 A 480/400/130
AES-4kW,D 35647 4.0 1 6 to 9 A 320/240/130
AES-4kW, D2M 35648 4.0 2 6 to 9 A 400/320/130
AES-4kW,D3M 35649 4.0 3 6 to 9 A 480/400/130
accessories
Electrical

AES-4kW,D4M 35650 4.0 4 6 to 9 A 480/400/130

AES...SD Art. no. kW Amount of controlled Motor protection current-range * Dimensions


motors
1-step L/B/H [mm]
AES-5.5kW, SD 35655 5.5 1 6 to 10 A 400/320/190
AES-5.5kW, SD2M 35656 5.5 2 6 to 10 A 480/400/190
AES-7.5kW, SD 35657 7.5 1 6 to 10 A 400/320/190
AES-7.5kW, SD2M 35658 7.5 2 6 to 10 A 480/400/190
AES-11kW, SD 35659 11.0 1 10 to 16 A 400/320/190
AES-15kW, SD 35660 15.0 1 16 to 24 A 480/400/190
AES-18.5kW, SD 35661 18.5 1 16 to 24 A 480/400/190
AES-22kW, SD 35662 22.0 1 24 to 32 A 480/400/190
AES-30kW, SD 35663 30.0 1 24 to 40 A 600/600/250

* Other currents possible on request.


384 | Electrical Accessories

AES...SS Art. no. kW Amount of controlled Motor protection current-range * Dimensions


motors
1-step 2-step L/B/H [mm]
AES-0.9kW, SS 35551 0.9 1 0.6 to 1 A 1.6 to 2.4 A 400/320/190
AES-0.9kW, SS2M 35593 0.9 2 0.6 to 1 A 1.6 to 2.4 A 480/400/190
AES-1.2kW, SS 35594 1.2 1 1 to 1A 2.4 to 4 A 400/320/190
AES-1.2kW, SS2M 35595 1.2 2 1 to 1.6 A 2.4 to 4 A 480/400/190
AES-1.7kW, SS 35596 1.7 1 2.4 to 4 A 4 to 6 A 400/320/190
AES-1.7kW, SS2M 35597 1.7 2 2.4 to 4 A 4 to 6 A 480/400/190
AES-2.2kW, SS 35598 2.2 1 2.4 to 4 A 4 to 6 A 400/320/190
AES-2.2kW, SS2M 35599 2.2 2 2.4 to 4 A 4 to 6 A 480/400/190
AES-2.5kW, SS 35600 2.5 1 2.4 to 4 A 6 to 10 A 400/320/190
AES-2.5kW, SS2M 35601 2.5 2 2.4 to 4 A 6 to 10 A 480/400/190
AES-3.2kW, SS 35602 3.2 1 2.4 to 4 A 6 to 10 A 400/320/190
AES-3.2kW, SS2M 35603 3.2 2 2.4 to 4 A 6 to 10 A 480/400/190
AES-4kW, SS 35664 4.0 1 2 to 4 A 6 to 10 A 400/320/190
AES-4kW, SS2M 35665 4.0 2 2 to 4 A 6 to 10 A 480/400/190
AES-5.5kW, SS 35666 5.5 1 4 to 6 A 10 to 16 A 400/320/190
AES-5.5kW, SS2M 35667 5.5 2 4 to 6 A 10 to 16 A 480/400/190
AES-7.5kW, SS 35668 7.5 1 6 to 10 A 10 to 16 A 400/320/190
AES-7,5kW, SS2M 35669 7.5 2 6 to 10 A 10 to 16 A 480/400/190
AES-11kW, SS 35670 11.0 1 10 to 16 A 16 to 24 A 400/320/190
AES-15kW, SS 35671 15.0 1 10 to 16 A 24 to 40 A 480/400/190
AES-18.5kW, SS 35672 18.5 1 16 to 24 A 24 to 40 A 480/400/190
AES-22kW, SS 35673 22.0 1 16 to 24 A 40 to 57 A 480/400/190
AES-30kW, SS 35674 30.0 1 16 to 24 A 40 to 57 A 600/600/250

AES...DA Art. no. kW Amount of controlled Motor protection current-range * Dimensions


motors
1-step 2-step L/B/H [mm]
AES-0.75kW, DA 35604 0.75 1 0.6 to 1 A 1,6 to 2,4A 400/320/190
AES-0,75kW, DA2M 35605 0.75 2 0.6 to 1 A 1,6 to 2,4A 480/400/190
AES-1,3kW, DA 35606 1.3 1 1 to 1.6 A 2,4 to 4,0A 400/320/190
AES-1,3kW, DA2M 35607 1.3 2 1 to 1.6 A 2,4 to 4,0A 480/400/190
AES-1,8kW, DA 35608 1.8 1 1 to 1.6 A 2.4 to 4 A 400/320/190
AES-1,8kW, DA2M 35609 1.8 2 1 to 1.6 A 2.4 to 4 A 480/400/190
AES-2,6kW, DA 35610 2.6 1 2.4 to 4 A 6 to 10 A 400/320/190
AES-2,6kW, DA2M 35611 2.6 2 2.4 to 4 A 6 to 10 A 480/400/190
AES-3,2kW, DA 35612 3.2 1 2.4 to 4 A 6 to 10 A 400/320/190
AES-3,2kW, DA2M 35613 3.2 2 2.4 to 4 A 6 to 10 A 480/400/190
AES-4kW, DA 35675 4.0 1 2.4 to 4 A 6 to 10 A 400/320/190
AES-4kW, DA2M 35676 4.0 2 2.4 to 4 A 6 to 10 A 480/400/190
AES-5,5kW, DA 35677 5.5 1 4 to 6 A 10 to 16 A 400/320/190
AES-5,5kW, DA2M 35678 5.5 2 4 to 6 A 10 to 16 A 480/400/190
AES-7,5kW, DA 35679 7.5 1 4 to 6 A 10 to 16 A 400/320/190
accessories
Electrical

AES-7,5kW, DA2M 35680 7.5 2 4 to 6 A 10 to 16 A 480/400/190


AES-11kW, DA 35681 11.0 1 4 to 6 A 16 to 24 A 400/320/190
AES-15kW, DA 35682 15.0 1 6 to 10 A 16 to 24 A 480/400/190
AES-18,5kW, DA 35683 18.5 1 10 to 16 A 24 to 40 A 480/400/190
AES-22kW, DA 35684 22.0 1 10 to 16 A 35 to 50 A 480/400/190
AES-30kW, DA 35685 30.0 1 16 to 24 A 40 to 57 A 600/600/250

* Other currents possible on request.


Electrical Accessories | 385

ARM-1 AMM-2
Smoke Detector with socket Multiple sensor smoke detector
Smoke detector with socket for connection Smoke detector (optical and thermal) with
with AES-ST3.1. With VdS-Approval and Accord- socket for connection with AES-ST3.1. With
ing to DIN-EN 54-7. High operating safety due VdS-Approval and According to DIN-EN 54-7.
to intelligent analysis of the optical signal. High operating safety due to intelligent analysis of the optical and
Art. no.: 35710 thermal signal.
Material: ABS Art. no.: 35711
Color: white Material: ABS
Enclosure class, motor: IP 40 Color: white
Enclosure class, motor: IP 40

DKM-2K DKT-3
Pushbutton signal Pushbutton switch
Pushbutton signal „smoke exhaust” made Pushbutton switch „smoke extraction” made
from plastic, with locking switch and buried from plastic. With protection class IP 42.
resetting. With indicator for being ready and Voltage: 12 - 48V DC.
pressed.

DKM-2K-GR DKM-2K-GE DKM-2K-OR DKM-2K-RT DKT-3GR DKT-3GE


Art. no. 35705 35706 35707 35712 Art. no. 35708 35709
Color grey yellow orange red Color grey yellow

FEP-AP FET-AP
Fire brigade switch Fire brigade switch
Fire brigade switch for switching by a key Fire brigade switch for smoke extraction with stand-
switch. Key switch (FEP-ZY / articlenr: 35713) ard key switch in wall mounting housing. With key
not contained. Fire brigade switch in a wall switch off/smoke extraction/ready.
mounting housing. Switch positions: ready/
smoke extraction.
Art. no.: 35704 Art. no.: 35703
Nominal voltage: 24 V DC Nominal voltage: 24 V DC
Protection class: I Protection class: I
Color: red Color: red/grey
Enclosure class: IP 44 Enclosure class: IP 54
Dimensions H/W/D: 125/125/70 mm Dimensions H/W/D: 160/80/80 mm
accessories
Electrical
386 | Accessories

Accessories

Filter boxes Coolers Silencers


Accessories

Heaters Shutters, dampers Flanges / Adapters


Accessories | 387

Flexible connections Protection guards Mounting clamps / feet Accessories

Roof sockets Weather protection Anti-vibration mounts


388 | Accessories

FK RSK Pressure drop

Fast clamps Back draft damper


Mounting clamps Back draft damper for
which facilitate the circular ducts, manufac-
installation and re- tured from galvanized
moval of fans for service and cleaning. Made sheet steel. The two blades are spring-load-
from galvanized sheet steel and fitted with ed, which means that the damper can also
an 8 mm neoprene lining which suppress- be mounted vertically.
es vibrations and ensures a tight fit. The
mounting clamps are clamped together by RSK Art. no. øD L1 L
two screws which allow for small differences 100 5597 99 5 90
in dimension. 125 5598 124 18 90
150 5599 149 30 90
FK Art. no. øD mm
160 5601 159 35 90
100 1607 100
200 5602 199 55 90
125 1608 125
250 5603 249 62.5 125
150 1609 150
315 5604 314 95.5 125
160 1610 160
355 9972 354 115 125 0 200 400 600 800 1000 1200 1400 1600 1800
200 1611 200
400 9973 399 137.5 125 45
200
250 1612 250
40
315 1613 315
10 35 250
355 1614 355
400* 1615 400 30

450* 1616 450 25


315
500* 1617 500 20
⌀D
* Note! Without hanging tabs 15
355/400

10

Hanging tabs 5

L1 L 0
0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 0,5

IGC
Intake grid
Intake grid for inside
or outside installation.
Connection diameters
ø100-315 mm, and is manufactured from
die-cast aluminium and supplied with a mesh
designed to keep out large insects.
IGC Art. no. ød øD
100 5581 100 125
125 5582 125 150
160 5583 160 185 øD = outside diameter
200 5584 200 225 ød = connection diameter
250 5585 250 275
315 5586 315 350

IGK
Pressure drop

Intake grid
Accessories

Intake grid manufactured


from galvanized sheet
steel with wall flange and
insect mesh. Connection
sleeve with rubber seal.

IGK Art. no. øA B


100 1630 100 37 Insect mesh
125 1631 125 37
160 1632 160 37
200 1633 200 41
Accessories | 389

VK Pressure drop

Gravity louvre
shutter VK

ps [Pa]
Louvre shutters for ver-
tical mounting on a wall.
The profiled vanes pro-
duce a strong upward
force which reduces the air resistance. This
means that the vanes opens fully at low air
velocities as well.
All the parts are manufactured in weath-
er-resistant and shockproof nylon material
(PVC containing special synthetic). The ro-
bust construction ensures that the vanes will
Air velocity in duct m/s
not become deformed or loose. Above size
45, the vanes are fitted with a cast coun-
terweight. Air velocity should not exceed 12 VK Art. no. A B C D ⌀E F G H
m/s. The louvre shutters are easy to install. 10** 5636 142 15 103 103 96 5 46 3
Wall plugs and screws are included above 12** 5638 164 12 115 115 117 5 38 4
size 15. 15 5605 178 20 130 130 152 4 50 5
20 5639 245 20 190 190 210 5 50 6
C G
25 5640 299 25 235 235 260 5 70 5
30 5641 347 26 274 274 310 5 70 6
35 5642 397 26 297 323 360 5 70 7
40 5643 460 26 364 373 423 5 65 8
ØE 45 5645 501 31 402 402 460 5 70 6
D
A

50 5646 549 31 452 452 510 5 95 7


ØF 56* 9951 610 30 530 530 530 5 80 14(2x7)
63* 5651 701 31 626 626 660 5 85 16(2x8)
71* 5653 749 31 663 663 710 5 90 18(2x9)
A B
100 9964 1040 40 972 - - - - -
*side by side shutters **Color: white H = amount of vanes

30
SG Art. no. øA øB C D E
SG 7.2 +0.8
0
100 5606 100 90 3.4 11.8 24.3
125 5607 125 110 3.4 11.8 24.3
Protection guard
0
12

150 5555 150 150 3.4 11.8 24.3


Protection grille for
160 5608 160 150 3.4 11.8 24.3
duct fans, mounted
200 5609 200 190 3.4 11.8 24.3
with three screws.
250 5610 250 250 3.4 11.8 24.3
315 5611 315 310 3.8 12.6 24.7
355 5612 355 350 3.8 12.6 24.7
B 400 5613 400 390 3.8 12.6 24.7
A
450 5614 450 450 3.8 12.6 24.7
2.8

500 5615 500 490 3.8 12.6 24.7


C
E

prio
M5
Accessories

mounting
39

168 145

bracket 2x Lalo 5,5x10 2x Lalo 5,5x7,5

Mounting bracket for prio 160/200


Mounting bracket for wall or ceiling mounting.
134

The bracket consist of galvanized steel.


Art. no.: 313239 / 313050 130
390 | Accessories

LDC Noise suppression dB (mid-frequency Hz)


LDC 63 125 250 500 1k 2k 4k 8k
Silencer 100-300 2 2 6 14 21 25 20 11
Easily-fitted 100-600 4 3 11 24 36 49 34 17
silencer for 100-900 5 4 15 34 50 50 48 23
circular ducts, fitted with a connection that
100-1200 6 5 19 45 50 50 50 29
complies with the spiral duct standard. The
125-300 2 2 6 13 16 20 15 10
LDC effectively reduces noise in the duct.
125-600 3 3 9 23 30 40 22 14
Two silencers can be used together in instal-
lations where noise reduction is a particular- 125-900 4 4 12 33 45 50 30 17
ly strong requirement. This is very effective. 125-1200 5 5 15 43 50 50 38 21
For the most effective noise reduction, the 150-300 1 2 4 10 12 15 8 8
silencer should be fitted immediately behind 150-600 - 3 7 20 27 31 16 11
a fan or bend. The silencer should be used 160-300 1 2 4 10 12 15 8 8
together with an insulated fan where there 160-600 2 3 7 19 27 29 14 11
is a requirement for noise reduction both in 160-900 2 4 10 28 42 43 20 15
the duct and in the surroundings as a whole. 200-300 1 2 5 8 10 11 5 5
Insulation thickness 50 mm.
200-600 2 3 7 16 21 23 9 8
200-900 2 4 8 24 32 34 13 10
250-600 3 2 7 13 17 16 8 6
250-900 3 4 8 20 26 23 10 8
l 315-600 0 2 6 11 14 9 4 5
L nom 315-900 1 3 7 16 22 12 6 7
355-900 - 3 6 13 18 10 6 7
400-900 1 3 5 10 13 7 5 6
Ød0
Ødi

LDC Art. no. L nom ødi ød0 l kg


100-300 8180 300 100 200 360 2.28
100-600 5188 600 100 200 660 4.09
100-900 5189 900 100 200 960 5.18
100-1200 5996 1200 100 200 1260 6.46
125-300 53722 300 125 224 365 2.66
125-600 5190 600 125 224 665 4.39
125-900 5191 900 125 224 965 6.20
125-1200 5997 1200 125 224 1265 7.47
150-300 53723 300 150 250 300 3.77
150-600 5199 600 150 250 600 5.37
160-300 53108 300 160 260 375 2.98
160-600 5192 600 160 260 670 5.37
160-900 5193 900 160 260 970 7.48
200-300 53369 300 200 300 385 4.11
200-600 5194 600 200 300 685 6.90
200-900 5195 900 200 300 985 9.74
250-600 51200 600 250 355 600 8.55
250-900 5196 900 250 355 900 11.7
315-600 5949 600 315 415 600 11.8
315-900 5197 900 315 415 900 16.3
355-900 5399 900 355 560 900 25.2
400-900 5198 900 400 600 900 24.3

LDC(B) Noise suppression dB (mid-frequency Hz)


LDC(B) 63 125 250 500 1k 2k 4k 8k
Silencer
315-1200 7 9 23 30 38 47 37 25
Circular straight silenc-
Accessories

400-1200 6 10 18 23 31 36 25 19
er with baffle.
Provided with a 100 500-1200 4 8 13 18 24 28 17 16
mm thick baffle. This provides greater at- 630-1200 3 8 10 13 18 18 12 12
tenuation across the entire range. Used
where increased attenuation is required and
the standard is not suitable. More suitable in l LDC(B) Art. No. ød1 ødy l kg
the larger sizes.
315-1200 9068 315 510 1200 32.6
Insulation thickness 100 mm.
400-1200 9081 400 625 1200 41.7
Ødy
Ød1

500-1200 9087 500 735 1200 48.8


630-1200 9088 630 880 1200 59.3
Accessories | 391

FFR
Filter cassette for
circular ducts G3 G3
The FFR filter cassette
is designed for bag fil-
ters of the G3, M5 or F7
standard filter types. The cassette is manu-
factured from galvanized sheet steel with
rubber-sealed circular connections and locks
with toggle fasteners.
The cassette is fitted with connections for
connecting to a pressure sensor. The filters
for FFR are BFR bag filters. Available in vari-
ous filter classes and are ordered separately
and supplied individually. The recommended
final pressure drop is 170 Pa for the G3 fil-
ter, 200 Pa for the M5 filter and 250 Pa for
the F7 filter.

Free area for filter change


D
B

øA
C

M5 M5
B E

øA B C D E
100 200 203 522 450
125 200 203 522 450
150 200 203 522 450
160 200 203 522 450
200 245 248 530 450
250 295 298 584 500
315 345 348 634 550
355 445 448 780 650
400 445 448 782 650

Filter Art. no. Bag filter Filter media


cassette
FFR 100 1766 BFR 100-160 G3, M5, F7
FFR 125 1768 BFR 100-160 G3, M5, F7
FFR 150 1769 BFR 100-160 G3, M5, F7 F7 F7
FFR 160 1770 BFR 100-160 G3, M5, F7
FFR 200 1773 BFR 200 G3, M5, F7
FFR 250 1776 BFR 250 G3, M5, F7
FFR 315 1779 BFR 315 G3, M5, F7
FFR 355 1782 BFR 355 G3, M5, F7
FFR 400 1783 BFR 400 G3, M5, F7

A
Accessories

Dimensions for filter classes G3/M5/F7 in mm:

BFR £A B No. of Art. no. Art. no. Art. no.


filter bags G3 M5 F7
100-160 187/187/188 250/250/235 2/2/3 5246 5239 5222
200 232/232/233 250/250/230 2/2/3 5247 5240 5223
250 282/282/283 300/300/285 2/2/4 5248 5241 5224
315 332/332/333 350/350/330 3/3/5 5249 5242 5226
355, 400 432/432/433 450/450/420 3/3/6 5250 5243 5227
392 | Accessories

FGR
Filter cassette for
circular ducts G3 G3
The FGR filter cassette
is fitted with a standard
type G3 panel filter.
The cassette housing is manufactured from
galvanized sheet steel with rubber-sealed
circular connections, toggle locks and dis-
posable filters. Replacement PFR filters are
sold in packs of five.
The filter cassette is suitable for use as a
supply-air filter in heavy industry and indus-
trial workshops. Nytrel panel filters (avail-
able for sizes 100 to 200) are recommended
for exhaust air from tumble driers. The rec-
ommended final pressure drop is 170 Pa for
FGR ø A B C D E
the G3 filter.
100 100 123 199 205 201 190
125 125 123 199 205 201 190
Free area for filter change 150 150 123 199 205 201 190
160 160 123 199 205 201 190
200 200 123 199 302 297 280
250 250 123 239 302 297 280
315 315 123 239 350 345 330
355 355 123 239 454 450 435
400 400 123 259 454 450 435

Filter cassette Art. no. Panel filter Filter


(incl. in FGR) media
FGR 100 1802 PFR 100-160 G3
FGR 125 1804 PFR 100-160 G3
FGR 150 1807 PFR 100-160 G3
Filter mounting FGR 160 1809 PFR 100-160 G3
FGR 200 1812 PFR 200 G3
FGR 250 1815 PFR 250 G3
FGR 315 1818 PFR 315 G3
FGR 355 1821 PFR 355 G3
FGR 400 1823 PFR 400 G3

VKK Free area Airflow


B
Pressure drop
C A
Back draft
E

ps [Pa]

damper
Back draft damper
for installation in
D

horizontal ducts.
The profiled vanes
produce a strong upward force which re-
duces the air resistance. This means that the
vanes open fully at low air velocities as well.
The box is manufactured from galvanized
sheet steel. The damper inside the box is
manufactured from weather-resistant and
Accessories

shock-proof nylon material. The robust con-


struction ensures that the vanes will not be-
come deformed or loose. Air velocity should
VKK Art. no. ø A B C D E Air velocity in duct m/s
not exceed 12 m/s.
100 1623 100 123 199 205 200 201
125 1624 125 123 199 205 200 201
160 1625 160 123 199 205 200 201
200 1626 200 123 199 302 300 297
250 1627 250 123 239 302 300 297
315 1628 315 123 239 350 345 345
400 1629 400 123 259 454 450 450
Accessories | 393

CB CB
Art. no.
100-0.4 100-0.6 125-0.6 125-1.2 125-1.8 150-1.2 150-2.1 150-2.7
5288 5376 5289 5290 5377 5378 5379 5380
Electrical duct Connection ø mm 100 100 125 125 125 150 150 150
heater Power kW 0,4 0,6 0,6 1,2 1,8 1,2 2,1 2,7
Duct heater with Voltage V 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 230 1~
spigot connection for standard spiral ducts. Current A 1,7 2,6 2,6 5,2 7,8 5,2 9,1 11,7
Manufactured from Aluzinc-coated sheet
Min. airflow m3/h 45 45 70 70 65 100 100 100
steel with a heating element in stainless
Weight kg 2.0 2.0 2.4 2.7 2.7 3.1 3.0 3.5
steel. The heater has integral overheat-
ing protection with a manual reset func- Controlled by Pulser Pulser Pulser Pulser Pulser Pulser Pulser Pulser
tion. The CB heater has rubber seals on the Wiring diagram CB-1 CB-1 CB-1 CB-1 CB-1 CB-1 CB-1 CB-1
connecting spigots. Suitable for control by
CB 150-5.0 160-1.2 160-2.1 160-2.7 160-5.0 200-2.1 200-3.0 200-5.0
room thermostat or Pulser. The minimum air
volume is based on a minimum air velocity Art. no. 5381 5291 5292 5382 5383 5384 5370 5371
of 1.5 m/s. These duct heaters are designed Connection ø mm 150 160 160 160 160 200 200 200
for a maximum output air temperature of Power kW 5,0 1,2 2,1 2,7 5,0 2,1 3,0 5,0
50°C. The CB can be installed in a horizon- Voltage V 400 2~ 230 1~ 230 1~ 230 1~ 400 2~ 230 1~ 230 1~ 400 2~
tal or vertical duct. In a horizontal duct, the Current A 12,5 5,2 9,1 11,7 12,5 9,1 13 12,5
connection box should be installed facing Min. airflow m3/h 100 115 115 115 115 180 180 180
upwards, or rotated 90° to one side. Instal-
Weight kg 4.2 3.1 3.2 3.5 4.2 3.9 4.2 4.7
lation with the connection box facing down-
Controlled by Pulser Pulser Pulser Pulser Pulser Pulser Pulser Pulser
wards is not allowed.
Wiring diagram CB-2 CB-1 CB-1 CB-1 CB-2 CB-1 CB-1 CB-2

CB 250-3.0 250-6.0 250-9.0 315-3.0 315-6.0 315-9.0 315-12.0 355-6.0


Art. no. 5385 5372 5373 5386 5374 5375 5387 5388
Connection ø mm 250 250 250 315 315 315 315 355
Power kW 3 6 9 3 6 9 12 6
Voltage V 230 1~ 400 2~ 400 3~ 230 1~ 400 2~ 400 3~ 400 3~ 400 2~
Current A 13 16 13 13 15 13 17,3 15
Min. airflow m3/h 280 280 280 430 430 430 430 550
Weight kg 4.9 5.8 6.7 5.8 5.8 6.9 8.5 7.0
Controlled by Pulser Pulser TTC Pulser Pulser TTC TTC Pulser
øD = connection diameter
Wiring diagram CB-1 CB-2 CB-3 CB-1 CB-2 CB-3 CB-4 CB-2
A = Heating elements
B = Overheat protection with automatic reset CB 355-9.0 355-12.0 400-6.0 400-9.0 400-12.0
C = Overheat protection with manual reset Art. no. 5389 5390 5391 5392 5393
E = Interlocking Connection ø mm 355 355 400 400 400
F = All phase breaker Power kW 9 12 6 9 12
H = Thyristor type Pulser or TTC Voltage V 400 3~ 400 3~ 400 2~ 400 3~ 400 3~
Current A 13 17,3 15 13 17,3
Pulser page 375 Min. airflow m³/h 550 550 700 700 700
TTC page 375
Weight kg 7.3 7.7 7.9 8.8 9.7
Sensors page 367
Controlled by TTC TTC Pulser TTC TTC
Wiring diagram CB-3 CB-4 CB-2 CB-3 CB-4

CB-1 230V~ CB-2 400V 2~ CB-3 230V 3~ 400V 3~ CB-4 12kW, 400V 3~

Accessories
394 | Accessories

CBM CBM
Art. no.
100-0.6
5479
125-1.2
5480
150-2.1
5481
160-2.1
5482
200-3.0
7593
200-5.0
5483
Duct heater with Connection ø mm 100 125 150 160 200 200
integral control Power kW 0.6 1.2 2.1 2.1 3.0 5.0
equipment Voltage V 230 1~ 230 1~ 230 1~ 230 1~ 230 1~ 400 2~
Duct heater with Current A 2.6 5.2 9.1 9.1 13.1 12.5
spigot connection for standard spiral circular Min. airflow m3/h 45 70 100 115 180 180
ducts. Manufactured from Aluzinc-coated Weight kg 2.3 3 3.5 3.5 4.4 4.8
sheet steel with a heating element in stain- Wiring diagram CBM-1 CBM-1 CBM-1 CBM-1 CBM-1 CBM-2
less steel. The heater has integral overheat-
ing protection with a manual reset function.
CBM 250-3.0 250-6.0 315-6.0 315-9.0 355-9.0 400-9.0
The CBM have rubber seals on the connect-
Art. no. 7595 9089 9091 5485 5486 5487
ing spigots. The temperature is set on the
cover of the duct heater. The unit is con- Connection ø mm 250 250 315 315 355 400
trolled by an integral electronic temperature Power kW 3.0 6.0 6 9 9 9
regulator, using so-called time-proportional Voltage V 230 1~ 400 2~ 400 2~ 400 3~ 400 3~ 400 3~
Pulse/Pause technology. This provides ex- Current A 13.1 15 15 13 13 13
tremely precise temperature control. As a Min. airflow m3/h 180 280 421 430 550 700
thyristor is used for adjusting the tempera- Weight kg 5 5.6 6.6 8 8.8 9.3
ture, the unit has no moving parts. This Wiring diagram CBM-1 CBM-2 CBM-2 CBM-3 CBM-3 CBM-3
means that it is silent and not susceptible to
wear and tear. Terminals for interlocking the
heater, via a pressure- and airflow guard are
available in the terminal box. The minimum
air volume is based on a minimum air veloc-
ity of 1.5 m/s. These duct heaters are de-
signed for a maximum output air tempera-
ture of 50°C.

All CBMs are delivered with duct sensor


TG-K330 (0-30°C) as standard.
øD = connection diameter

CBM-1 230V~ CBM-2 400V 2~ CBM-3 400V 3~


Accessories

A = Heating elements
B = Overheat protection with automatic reset
C = Overheat protection with manual reset
E = Interlocking
F = All phase breaker
H = Thyristor type Pulser or TTC
J = Sensor
T = Air flow switch/Pressure switch
Accessories | 395

VBC Ødy

Water-heating
battery
Water-heating battery

H+8
ØD

F
for heating air in ven-
tilation systems with
circular ducts. Aluzinc-
coated casing, heat transmission element
B G K G
with copper tubes and aluminium fins. Re-
movable cover for cleaning the unit. L

The water-heating battery can be installed


in a horizontal or a vertical duct with option- VBC øD B H Ødy F G K L kg
al direction of airflow. 100-2 100 238 180 10 137 40 276 356 3.7
100-3 100 238 180 10 100 40 276 356 3.8
Max operating temperature 150°C. 125-2 125 238 180 10 137 40 276 356 3.5
Max operating pressure 1.6 MPa (16 Bar) 125-3 125 313 255 10 175 40 276 356 5.5
2-and 3-rows batteries.
160-2 160 313 255 10 212 40 276 356 5.4
160-3 160 313 255 10 175 40 276 356 5.4
200-2 200 313 255 10 212 40 276 356 5.3
Water out 200-3 200 398 330 22 250 40 276 356 8.2
250-2 250 398 330 22 250 40 276 356 7.7
250-3 250 473 405 22 325 40 276 356 10.2
315-2 315 473 405 22 325 40 276 356 9.9
315-3 315 557 504 22 400 40 276 356 13.4
Water in 400-2 400 557 504 22 400 65 276 406 13.1
400-3 400 707 539 22 425 65 330 460 17.9
500-2 500 707 529 22 425 65 330 460 16.9

Coil calculation 2 rows


VBC 100-2 125-2 160-2 200-2 250-2 315-2 400-2 500-2
Art. no. 5456 5457 5458 5459 5460 5461 5462 9837
Air flow (m3/s) 0.04 0.06 0.1 0.15 0.25 0.39 0.63 0.9
Pressure drop (Pa) 35 72 40 73 68 69 77 45
DT air at T water 60/40, ˚C 16 13 19.9 17.3 17.5 18.1 17.7 19.4
Water flow rate (l/s) 0.01 0.01 0.03 0.04 0.07 0.11 0.18 0.28
Water speed (m/s) 0.15 0.2 0.4 0.6 0.5 0.5 0.6 0.7
Pressure drop (kPa) 0.1 0.1 3 5 3 3 4 6.6
Power (kW) 0.85 1.0 2.6 3.5 5.7 9.2 14.6 22.7
DT air at T water 90/70, ˚C 32.5 28.3 35.8 30.4 31.7 32 31 31
Water flow rate (l/s) 0.02 0.03 0.06 0.07 0.13 0.2 0.31 0.31
Water speed (m/s) 0.3 0.4 0.8 1.1 0.9 1 1.1 1.1
Pressure drop (kPa) 1 1 8 13 7 8 10 10
Power (kW) 1.7 2.2 4.6 6.1 10.3 16.3 25.5 25.5

Coil calculation 3 rows


VBC 100-3 125-3 160-3 200-3 250-3 315-3 400-3
Art. no. 9838 9839 9840 9841 9843 9844 9845
Air flow (m3/s) 0.04 0.06 0.1 0.15 0.25 0.39 0.63
Pressure drop (Pa) 39 17.2 41 29 31.2 35 36.3
DT air at T water 60/40, ˚C 25,9 33.4 29.3 30.7 30.5 30.2 30.3
Water flow rate (l/s) 0.02 0.03 0.05 0.07 0.12 0.19 0.3
Water speed (m/s) 0.24 0.47 0.68 0.54 0.59 0.69 0.74
Accessories

Pressure drop (kPa) 0.85 5.33 11 5.36 6.23 8.28 10.10


Power (kW) 1.35 2.6 3.8 6 9.93 15.3 24.74
DT air at T water 90/70, ˚C 47.4 56.2 49.7 52.1 51.6 51 50.8
Water flow rate (l/s) 0.03 0.05 0.08 0.13 0.21 0.32 0.51
Water speed (m/s) 0.45 0.8 1.17 0.92 1.02 1.17 1.26
Pressure drop (kPa) 2.65 14 29.5 14.1 16.2 21.4 26.1
Power (kW) 2.46 4.38 6.46 10.17 16.8 25.87 41.6
396 | Accessories

Diagrams VBC

VBF
Water-
heating
battery

Water-heating battery with integral M5 bag


filter for heating air in ventilation systems
with circular ducts. Casing manufactured
from galvanized sheet steel, with copper
tubes and aluminium fins. Inspection cover
facilitates cleaning and replacement of filter.
The water-heating batter must be in-
VBF øD A B H L ødy F kg
stalled in a horizontal duct. The bag filter
100 100 665 254 266 599 22 213 8
Accessories

must always be fitted vertically. The VBF is


125 125 665 254 266 599 22 213 8
fitted with connections for connecting to a
filter monitor. 160 160 665 254 266 599 22 213 8
The Systemair fan selection programme 200 200 665 254 266 599 22 213 8
includes a special selection programme for 250 250 795 354 366 699 22 313 12
water-heating batteries. The recommended 315 315 895 454 466 799 22 413 17
final pressure drop is 200 Pa. 355 355 920 454 466 799 22 413 17
400 400 920 454 466 799 22 413 17
Accessories | 397

VBF Bag filter Filter class


Water out
100 BFR 200 G3, M5, F7
125 BFR 200 G3, M5, F7
160 BFR 200 G3, M5, F7
200 BFR 200 G3, M5, F7
250 BFR 315 G3, M5, F7
Water in 315 BFR 355 G3, M5, F7
355 BFR 355 G3, M5, F7
400 BFR 355 G3, M5, F7

Coil calculation 2 rows


VBF 100 125 160 200 250 315 355/400
Art. no. 1724 1730 1731 1732 1733 1734 1735/1736
Air flow (m3/s) 0.04 0.05 0.12 0.16 0.17 0.28 0.44
Air velocity, (m/s) 1.2 1.6 3.5 4.6 1.8 1.7 2.7
DT air at T water 60/40, ˚C 23.3 20.9 14.3 12.6 25.9 26.2 21.5
Water flow rate (l/s) 0.01 0.02 0.03 0.03 0.06 0.11 0.14
Water speed (m/s) 0.1 0.1 0.2 0.2 0.5 0.4 0.5
Pressure drop (kPa) 0.1 0.2 0.4 0.5 3.5 1.6 2.6
Power (kW) 1.17 1.35 2.1 2.4 5.31 8.82 11.67
DT air at T water 90/70, ˚C 44 39.9 28.2 25 44.3 44.9 37.2
Water flow rate (l/s) 0.03 0.03 0.03 0.06 0.11 0.18 0.24
Water speed (m/s) 0.2 0.2 0.4 0.4 0.8 0.7 0.9
Pressure drop (kPa) 0.4 0.5 1.2 1.6 8.1 3.7 6.3
Power (kW) 2.2 2.58 4.13 4.76 8.97 15.11 20.18
Filter media M5 M5 M5 M5 M5 M5 M5

Diagrams VBF

VBF 355/400

Accessories

VBF 355/400

VBF 355/400
398 | Accessories

CWK
ødy

Water-cooling
battery for
circular ducts

H+8
øD

F
H
G½"
Casing manufac-
*
tured from gal-
vanized sheet steel with copper tubes and B
G K G
aluminium fins. Inspection covers for easy L *) Condensate drain
cleaning and maintenance. Connection
sleeves with rubber seal.
Max. operating temperature 150°C CWK Art. no. øD B H ødy F G K L kg
Max. operating pressure 1.6 MPa (16Bar) 100-3-2.5 30019 100 251 180 10 100 40 276 356 4.4
125-3-2.5 30021 125 326 255 10 175 40 276 356 6.5
160-3-2,5 30022 160 326 255 10 175 40 276 356 6.7
200-3-2.5 30023 200 411 330 22 250 40 276 356 9.4
250-3-2.5 30024 250 486 405 22 325 40 276 356 11
315-3-2.5 30025 315 560 504 22 400 40 276 356 14.3
400-3-2.5 30026 400 710 529 22 425 65 330 460 19.5

Coil calculation
Air Water
Flow Velocity Pressure Before Before After Capacity Flow Pressure
CWK (m3/h) m/s drop (Pa) (˚C) (% RH) (˚C) (kW) (l/s) drop (kPa)
100-3-2.5 54 2 7 25 50 14.3 0.2 0.01 < 0.5
54 2 7 30 45 15.8 0.4 0.01 1
100 3.5 22 25 50 16.4 0.3 0.01 1
100 3.5 22 30 45 18.5 0.5 0.02 2
145 5 58 25 50 17.5 0.4 0.02 1
145 5 58 30 45 20.0 0.6 0.02 3
125-3-2.5 85 2 3 25 50 12.6 0.5 0.02 3
85 2 3 30 45 13.5 0.7 0.03 5
150 3 9 25 50 14.5 0.7 0.03 5
150 3 9 30 45 15.7 1.1 0.04 10
215 4.5 18 25 50 15.6 0.8 0.03 7
215 4.5 18 30 45 17.0 1.4 0.05 16
160-3-2.5 145 2 9 25 50 14.4 0.7 0.03 4
145 2 9 30 45 15.6 1.0 0.04 10
250 3.5 24 25 50 16.1 0.9 0.04 8
250 3.5 24 30 45 17.4 1.5 0.06 20
355 5 45 25 50 17.0 1.1 0.04 11
355 5 45 30 45 18.4 1.3 0.08 32
200-3-2.5 225 2 6 25 50 14.1 1.0 0.05 2
225 2 6 30 45 15.3 1.6 0.06 5
390 3.5 17 25 50 15.9 1.4 0.06 4
390 3.5 17 30 45 17.3 2.3 0.09 9
555 5 33 25 50 16.9 1.7 0.07 5
555 5 33 30 45 18.4 3.1 0.12 15
250-3-2.5 360 2 6 25 50 14.2 1.6 0.06 2
360 2 6 30 45 15.4 2.5 0.10 5
630 3.5 18 25 50 16.0 2.2 0.09 4
630 3.5 18 30 45 17.3 3.8 0.15 10
900 5 34 25 50 17.0 2.7 0.11 6
900 5 34 30 45 18.2 5.1 0.20 17
315-3-2.5 560 2 7 25 50 14.5 2.4 0.10 3
560 2 7 30 45 15.4 3.9 0.16 7
985 3.5 20 25 50 16.1 3.4 0.13 5
985 3.5 20 30 45 17.2 6.1 0.24 14
Accessories

1410 5 39 25 50 17.0 4.3 0.17 8


1410 5 39 30 45 18.1 8.3 0.33 25
400-3-2.5 900 2 9 25 50 15.2 3.4 0.14 2
900 2 9 30 45 16.3 5.8 0.23 5
1590 3.5 25 25 50 16.8 4.8 0.19 4
1590 3.5 25 30 45 17.8 9.3 0.37 12
2280 5 49 25 50 17.6 6.1 0.24 6
2280 5 49 30 45 18.6 12.8 0.51 22
Accessories | 399

DS GFL ORH
Rectangular Counterflange Outlet hood
flexible connec- Used as a flange for Outlet protection to avoid
tions mounting to the duct system. Manufactured foreign objects to enter
from galvanized sheet steel. Suitable for rec- into the unit. It consists of
tangular ducts. a galvanized steel frame fitting into the out-
Flexible lengths from 100 to 158 mm.
let spigot with a grill of the same material
covering the total outlet surface.

A C
B+40
B+20
B

A
A+20
A+40

B
120
60

DS Art. no. A B GFL Art. A1 A2 B1 B2 C1 C2 Pos. KVD A B C


30-15 1537 300 150 No. 1 7/7 273 249 52
40-20 1539 400 200 40-20 2705 400 200 420 220 440 240 2 9/7 + 9/9 339 305 52
50-25 1542 500 250 50-25 2706 500 250 520 270 540 290 3 10/8 + 10/10 367 330 52
50-30 1544 500 300 50-30 2707 500 300 520 320 540 340 4 12/9 + 12/12 427 382 52
60-30 1547 600 300 60-30 2708 600 300 620 320 640 340 5 5/8 290 124 52
60-35 1549 600 350 60-35 2709 600 350 620 370 640 390
70-40 1551 700 400 70-40 2710 700 400 720 420 740 440
80-50 1553 800 500 80-50 2711 800 500 820 520 840 540
100-50 1555 1000 500

SRK
Volume control L SRK Art. no. L B
damper
40-20 7020 400 201
A valve with the same ø15
50-25 7021 500 251
flange system as rec-
B

50-30 7022 500 301


tangular duct fans. Air tightness class 3. The
60-30 7023 600 301
shutter valve consists of a number of blades 20 60-35 7024 600 351
20

which close towards each other. These are 140

mounted inside a steel sleeve on bushes 70-40 7025 700 401


made of glass-fibre reinforced nylon. The 80-50 7028 800 501
blades are connected via a linkage on the 100-50 7029 1000 501
outside of the steel-plate sleeve coupling.
The linkage is protected so that the valve
Pressure drop
can be insulated together with the duct. The
blades and sleeve coupling are manufac- 500 1000 2000 3000 5000 10000 15000 m3/h
tured from galvanized sheet steel. 50
Pa

30
20 5 35
60
-3 -35 0-
80 10
20 25 K K K 0 0 50
- - -30 SR 0-30 SR SR 0-4 0-5 0-
40 50 50 7 8 8 10
10 K K R K K K K K
SR SR S 0 R
-3 S 0-40 0-40 S
R R S R
Accessories

S
60 6 7
K K K
5 SR SR SR

2
150 200 300 500 1000 2000 3000 4000 l/s
400 | Accessories

LDR
Silencer for

c/c = H + 20
rectangular
ducts
Easily-fitted silencer immediately before or
after the KE, KT, RS and RSI range of rectan-
gular duct fans. Effectively suppresses noise c/c = B + 20
transmitted to the duct. The silencer should
be used in conjunction with an insulated
LDR Art. no. B H kg
fan where there is a requirement for noise
suppression both in the duct and in the sur- 30-15 5068 300 150 10
roundings as a whole. All silencers are sup- 40-20 5069 400 200 13
plied with a universal flange suitable for PG 50-25 5070 500 250 17
flange or Metu profile. 50-30 5071 500 300 19
60-30 5072 600 300 21
NOTE! Ensure that LDR silencer is mounted in 60-35 5073 600 350 23
the correct position. Failure to do this will re- 70-40 5074 700 400 27
sult in air starvation and high pressure drop 80-50 5075 800 500 34
being experienced.
100-50 5067 1000 500 41

Noise suppression dB (mid-frequency Hz)


LDR 125 250 500 1k 2k 4k 8k
30-15 7 15 18 25 25 19 19
40-20 5 9 15 23 16 12 10
50-25 10 15 25 25 20 15 12
50-30 8 15 20 31 17 14 11
60-30 8 15 20 31 17 14 11
60-35 7 13 17 18 13 10 8
70-40 7 11 14 14 10 8 6
80-50 6 8 10 11 8 6 3
100-50 6 8 10 11 8 6 3

Pressure drop calculation for rectangular Front area m2 P


silencers LDR 30-15 0.045 3.5
These calculations apply only if the silencer
LDR 40-20 0.08 3.6
is connected to a duct at both ends.
LDR 50-25 0.125 3.7
LDR 50-30 0.15 3.3
Pressure drop

Example: Calculation of pressure drop for the


LDR 60-35 (with fan model RSI 60-35 M3~) LDR 60-30 0.18 3.3
using the diagram to the right. LDR 60-35 0.21 3.0
LDR 70-40 0.28 3.1
1. Start by defining the front area, see the LDR 80-50 0.40 3.6
table below. LDR 100-50 0.50 3.6
2. Move horizontally to the right until you
reach the designated air flow in diagram
B.
3. Go up vertically to diagram A and the
correct p value (see the table).
4. Then continue horizontally to the left
and read off the pressure drop.

In this example, the pressure drop is 27 Pa.


Accessories

Duct area m2
Accessories | 401

FFK FFK Art. no. Bag filter Filter media Pressure drop
Filter cassette 30-15 1748 BFK 30-15 M5, F7
rectangular 40-20 1750 BFK 40-20 M5, F7
A filter cassette 50-25 1752 BFK 50-25 M5, F7 M5
designed for bag 50-30 1755 BFK 50-30 M5, F7
filters standard 60-30 1758 BFK 60-30 M5, F7
type M5 or F7. The 60-35 1761 BFK 60-35 M5, F7
cassette housing is
70-40 1762 BFK 70-40 M5, F7
manufactured from galvanized sheet steel.
80-50 30236 BFK 80-50 M5, F7
It has a hinged cover underneath fitted with
100-50 30237 BFK 100-50 M5, F7
a quick release latch, which makes it easy to
replace the filter. The filter cassette can be
connected directly on to the duct and should
always be fitted in a flat or vertical position.
If fitted vertically, the direction of the air
flow must be downwards so that the filter
bags do not collapse. BFK filter, in the M5 or
B
F7 filter classes, are to be ordered separate-
ly. The recommended final pressure drop is
200 Pa for the M5 filter and 250 Pa for the
F7 filter. The cassette is fitted with connec-
tions for connecting to a pressure sensor. A l M5

BFK A B I No. of
filer bags
30-15 286/287 142/143 300/280 2/5
40-20 386/387 192/193 400/360 3/5
50-25 486/487 242/243 430/370 4/7
50-30 486/487 292/293 490/355 4/7
60-30 586/587 292/293 540/520 4/8
60-35 586/587 342/343 590/515 4/8
FFK A B C D E F
70-40 686/687 392/393 700/625 5/9
30-15 340 190 402 250 320 170
80-50 785/785 490/490 600/600 6/10
40-20 440 240 502 350 420 220
100-50 985/985 490/490 600/600 7/14
50-25 540 290 532 350 520 270
50-30 540 340 562 350 520 320
60-30 640 340 642 350 620 320 BFK Art. no. Art. no.
60-35 640 390 717 350 620 370 M5 F7
70-40 740 440 787 420 720 420 30-15 5233 5225
80-50 840 540 882 530 820 520
40-20 5217 5216
100-50 1040 540 882 530 1020 520
50-25 5218 5228
50-30 5219 5229
60-30 5244 5230
60-35 5220 5231
70-40 5245 5232
80-50 30238 30239
100-50 30240 30241 Accessories
402 | Accessories

RB RB
Art. no.
40-20/9
9627
40-20/15
9628
50-25/15
9629
50-25/22
9633
50-30/15
9635
50-30/27
9637
Duct heater for Power kW 9 15 15 22 15 27
rectangular ducts Voltage V 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Manufactured from alu- Current A 13 22 22 31,8 22 39
zinc coated sheet steel with a Min. air flow m³/h 450 450 700 700 850 850
heating element in stainless steel. The heat- Weight kg 9.2 16 14.9 19.9 15.6 23.9
er has integral overheating protection with
a manual reset function. Suitable for control
RB 60-30/22 60-30/34 60-35/27 60-35/45 70-40/27 70-40/45
by room thermostat or TTC. The minimum air
volume is based on a minimum air velocity Art. no. 9638 9641 9643 9644 9645 9646
of 1.5 m/s. These duct heaters are designed Power kW 22 34 27 45 27 45
for a maximum output air temperature of Voltage V 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
40°C. Current A 31,8 49,1 39 65 39 65
Min. air flow m³/h 1000 1000 1000 1000 1600 1600
Weight kg 24.9 23.5 23.1 30.6 23.1 26.5

RB 80-50/45 80-50/68 100-50/45 100-50/68 100-50/80


Art. no. 9647 9648 9649 9650 9661
Power kW 45 68 45 68 80
Voltage V 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
Current A 65 98,2 65 98,2 116
Min. air flow m³/h 1600 2200 2800 2800 2800
Weight kg 30.5 39 33.6 42.1 42.1
RB B H D
40-20/9-1 400 200 370
40-20/15-1 400 200 500 TTC p. 375
50-25/15-1 500 250 370
Sensors p. 377
50-25/22-2 500 250 500
50-30/15-1 500 300 370
F1 Overheat protection,
50-30/27-2 500 300 500
automatic (60°C)
60-30/22-2 600 300 500 F2 Overheat protection,
manual (120°C)
60-30/34-2 600 300 500
F2 F1
60-35/27-2 600 350 370
60-35/45-3 600 350 500
70-40/27-2 700 400 370
70-40/45-3 700 400 370 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
400V 3~ 400V 3~ 400V 3~ 400V 3~ 400V 3~
80-50/45-3 800 500 370
RB 80-50/68-4 800 500 370 15 14 13 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 RB 100-50/80-5
16 kW 16 kW 16 kW 16 kW 16 kW
RB 80-50/68-4 1000 500 370 18,6 … 21,1 18,6 … 21,1 18,6 … 21,1 18,6 … 21,1 18,6 … 21,1
21,2 … 24,1 A 21,2 … 24,1 A 21,2 … 24,1 A 21,2 … 24,1 A 21,2 … 24,1 A
RB 100-50/68-4 1000 500 370
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 RB 100-50/68-4
RB 100-50/80-5 1000 500 370 17 kW 17 kW 17 kW 17 kW RB 80-50/68-4
17,5 … 19,9 17,5 … 19,9 17,5 … 19,9 17,5 … 19,9
22,5 … 25,6 A 22,5 … 25,6 A 22,5 … 25,6 A 22,5 … 25,6 A

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 RB 100-50/45-3
15 kW 15 kW 15 kW RB 80-50/45-3
19,9 … 22,6 19,9 … 22,6 19,9 … 22,6 RB 70-40/45-3
19,9 … 22,6 A 19,9 … 22,6 A 19,9 … 22,6 A RB 60-35/45-3

12 11 10 9 8 7 6 5 4 3 2 1 RB 60-30/34-2
17 kW 17 kW
17,5 … 19,9 17,5 … 19,9
22,5 … 25,6 A 22,5 … 25,6 A

12 11 10 9 8 7 6 5 4 3 2 1 RB 70-40/27-2
13,5 kW 13,5 kW RB 60-35/27-2
22,1 … 25,1 22,1 … 25,1 RB 50-30/27-2
17,9 … 20,3 A 17,9 … 20,3 A

12 11 10 9 8 7 6 5 4 3 2 1 RB 60-30/22-2
11 kW 11 kW RB 50-25/22-2
27,1 … 30,8 27,1 … 30,8
14,6 … 16,5 A 14,6 … 16,5 A
Accessories

9 8 7 6 5 4 3 2 1 RB 50-30/15-1
15 kW RB 50-25/15-1
19,9 … 22,6 RB 40-20/15-1
19,9 … 22,6 A

9 8 7 6 5 4 3 2 1 RB 40-20/9-1
9 kW
33,1 … 37,6
11,9 … 13,5 A
Accessories | 403

RBM RBM
Art. no.
40-20/9
5450
50-25/15
5451
50-30/15
5452
60-30/27
5453
60-35/27
5454
70-40/27
5455
Duct heater Power kW 9 15 15 27 27 27
for rectangular Voltage V 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~
ducts Current A 13 22 22 39 39 39
Duct heater with Min. air flow m³/h 450 700 850 1000 1200 1600
integral control equipment. Manufactured Weight kg 19 20.2 21 26.4 27 29.7
from alu-zinc coated sheet steel with a heat-
ing element in stainless steel. The heater has
integral overheating protection with a manual
reset function. The unit is controlled by an 200 + B + 19
integral electronic temperature regulator, us- 200 B 19

19
ing so-called time-proportional Pulse/Pause
technology. This provides extremely precise
temperature control. As a thyristor is used for
c/c = B + 20
adjusting the temperature, the unit has no

H + 38
H
moving parts. This means that it is silent and
not susceptible to wear and tear. The RBM is
supplied with a complete and fully-connect-
ed control system including contactors and ø10 (8x) c/c = B + 20

19
alarm relays. This minimises the installation
cost. The external installation requirements
are: mains power supply, control circuit, dial D
for setting required temperature, sensor and 35 35
a possible alarm circuit. The minimum air
volume is based on a minimum air velocity of
1.5 m/s. These duct heaters are designed for
a maximum output air temperature of 40°C.
All RBM are delivered with a TG-R430
room sensor with adjustment of desired value.

RBM B H D
A = Heating elements Sensors p. 377
40-20/9 400 200 500 B = Overheat protection with automatic
50-25/15 500 250 500 reset
50-30/15 500 300 500 C = Overheat protection with manual reset
60-30/27 600 300 500 E = Flow control
60-35/27 600 350 500 H = Thyristor ( or TTC)
70-40/27 700 400 500 J = Sensor
K = Set value adjustment
Calculation of required heating power K/J = Combined room sensor and set value
P=qv x air density x delta t adjustment
T = Air flow switch/Pressure switch
P = power in kW
qv = air volume in m3/s
air density = 1.2 kg/m3 at 20°C
delta T = temperature difference

Accessories
404 | Accessories

PGK
58 56 B 17 K M
9 9
Ø10 (8x) N

Cold water-

9
cooling Tapping for venting
Tapping for drainage

I
battery for 21

rectangular
ducts

60

9
Casing manufactured from galvanized sheet G½"
330

steel. Water battery from copper tubes and 395

aluminium fins. Air vent and drain valve in-


PGK Art. no. B H I K M N
cluded. Drip pan manufactured from stain-
40-20-3 6604 438 238 70 176 43 R 3/4
less steel and condensate connection (R½").
Max. working pressure 1.6 MPa (16 bar). For 50-25-3 6606 538 288 120 176 43 R 3/4
water connection left or right. Two inspec- 50-30-3 6608 538 338 175 176 43 R 3/4
tion covers for cleaning and maintenance. 60-30-3 6610 638 338 170 176 43 R 3/4
Droplet separator DE as an accessory regard- 60-35-3 6612 638 388 220 176 43 R 3/4
less of air direction. Recommended for air 70-40-3 6616 738 438 250 170 55 R1
velocities from 2.5 m/s. 80-50-3 6619 838 538 340 170 55 R1
100-50-3 6601 1038 538 350 170 55 R1

Coil calculation, water temp 6/12°C


Air flow Air Air Air Air Air after Capacity Water Water
PGK velocity pressure before before flow pressure
drop drop
[m3/h] m/s (Pa) (ºC) (% RH) (ºC) (kW) (l/s) (kPa)
40x20-3-2,0 576 2 31 25 50 17.0 1.53 0.06 1
576 2 36 30 45 19.0 2.50 0.10 3
NOTE! Droplet separator DE must be ordered
864 3 66 25 50 18.4 1.89 0.08 2
extra. Recommended for air velocities from 864 3 72 30 45 20.2 3.26 0.13 5
2.5 m/s. 1152 4 113 25 50 19.2 2.20 0.09 2
1152 4 119 30 45 20.8 4.15 0.17 7
50x25-3-2,0 900 2 31 25 50 17.0 2.38 0.09 2
900 2 36 30 45 18.6 4.27 0.17 5
Pressure drop DE, droplet eliminator
1350 3 66 25 50 18.2 3.02 0.12 3
1350 3 72 30 45 19.4 6.16 0.25 9
Pressure drop delta p in Pa

1800 4 113 25 50 18.9 3.61 0.14 4


1800 4 119 30 45 19.8 8.34 0.33 15
50x30-3-2,0 1080 2 31 25 50 17.1 2,83 0.11 1
1080 2 36 30 45 18.8 4.93 0.20 4
1620 3 66 25 50 18.4 3.56 0.14 2
1620 3 72 30 45 19.7 6.94 0.28 7
2160 4 113 25 50 19.1 4.22 0.17 3
2160 4 119 30 45 20.1 9.40 0.37 12
60x30-3-2,0 1296 2 31 25 50 17.3 3.3 0.13 1
1296 2 36 30 45 19.0 5.69 0.23 3
1944 3 66 25 50 18.6 4.13 0.16 2
1944 3 72 30 45 19.8 8.12 0.32 6
2592 4 113 25 50 19.3 4.90 0.20 3
Air velocity in m 2 2592 4 119 30 45 20.1 11.18 0.45 11
60x35-3-2,0 1512 2 31 25 50 17.3 3.86 0.15 1
1512 2 36 30 45 19.0 6.64 0.26 3
2268 3 66 25 50 18.6 4.82 0.19 2
2268 3 72 30 45 19.8 9.48 0.38 6
3024 4 113 25 50 19.3 5.72 0.23 3
3024 4 119 30 45 20.1 13.05 0.52 11
70x40-3-2,0 1920 2 47 25 50 17.1 5.02 0.20 1
1920 2 55 30 45 18.1 8.66 0.35 3
2880 3 91 25 50 18.5 6.20 0.25 1
2880 3 100 30 45 18.8 12.94 0.52 4
3840 4 142 25 50 19.3 7.26 0.29 2
Accessories

3840 4 151 30 45 19.0 18.41 0.73 8


80x50-3-2,0 2743 2 47 25 50 17.1 7.20 0.29 1
2743 2 55 30 45 17.6 13.59 0.54 3
4115 3 91 25 50 18.4 9.04 0.36 1
4115 3 100 30 45 18.0 21.61 0.86 6
5486 4 142 25 50 19.0 10.82 0.43 2
5486 4 151 30 45 18.6 28.41 1.13 10
100x50-3-2,0 3429 2 47 25 50 17.5 8.56 0.34 1
3429 2 55 30 45 17.9 16.13 0.64 2
5144 3 91 25 50 18.7 10.72 0.43 1
5144 3 100 30 45 18.0 26.77 1.07 6
6858 4 142 25 50 19.3 12.85 0.51 2
6858 4 151 30 45 18.6 35.52 1.41 10
Accessories | 405

DXRE Coil calculation


Refrigerant R407C, 5 ºC
Rectangular Air Air in Air in Air out Output Refrigerant Refrigerant
duct cooler Air flow
pressure flow pressure
with DX coil drop drop
DXRE (m3/h) (Pa) (ºC) (% RH) (ºC) (kW) (kg/h) (kPa)
40x20-3-2.5 575 32 25 50 15.8 2.2 51 3
• Same model for left-hand or right-hand 575 36 30 50 18.8 3.2 75 6.1
installation (reversible coil) 865 60 25 50 16.9 2.7 63 4.3
• Stainless steel condensate drip tray. A 865 68 30 50 20.4 3.9 90 8.7
droplet eliminator can be fitted regardless 1150 91 25 50 17.5 2.8 65 4.9
of the direction of air flow 1150 107 30 50 21.2 4.4 104 11.3
• Easily removable drip tray to simplify 50x25-3-2.5 900 32 25 50 15.8 3.4 80 3.2
cleaning and inspection 900 36 30 50 18.7 5 118 6.6
1350 60 25 50 16.9 4.2 99 5
1350 69 30 50 20.1 6.3 147 9.8
DXRE are mostly used for central cooling of
1800 92 25 50 18 4.4 103 5.2
the ventilation air but can also be used for
1800 108 30 50 21.2 7.1 165 12.1
individual cooling of the air supplied to indi-
50x30-3-2.5 1080 32 25 50 15.5 4.3 101 6.1
vidual rooms (zones).
1080 36 30 50 18.3 6.4 149 11.9
1620 62 25 50 16.6 5.4 126 8.8
The DXRE is intended for installation in a 1620 70 30 50 19.8 7.9 186 17.6
horizontal duct, with the air flow in either 2160 97 25 50 17.3 6.3 147 11.6
direction (reversible coil). 2160 110 30 50 20.9 8.9 208 21.7
60x30-3-2.5 1300 33 25 50 15.4 5.3 116 8.4
We recommend that a DE droplet eliminator 1300 37 30 50 17.8 8.2 180 18.5
(accessory) should be installed on the outlet 1950 63 25 50 16.5 6.6 145 12.6
side of the coil if the air velocity is in excess 1950 71 30 50 19.6 9.7 213 25.2
of 2.5 m/s. This prevents water droplets be- 2600 99 25 50 17.3 7.7 170 16.7
ing entrained by the air flow out into the 2600 112 30 50 20.8 11 241 31.5
duct system. 60x35-3-2.5 1510 32 25 50 15.5 6 131 7.5
1510 36 30 50 18.4 8.7 192 12.8
2270 62 25 50 16.7 7.5 164 10.1
2270 70 30 50 19.8 11 242 18.6
3025 97 25 50 17.4 8.6 189 12.5
3025 110 30 50 21 12.4 272 22.6
70x40-3-2.5 2015 40 25 50 14.7 8.6 188 7.6
2015 44 30 50 17.4 12.5 274 13.3
3020 72 25 50 16.3 9.6 211 9
3020 83 30 50 19.3 14.7 323 17.4
4030 112 25 50 16.5 11.2 246 11.3
R S B
9 9
4030 130 30 50 20.2 16.9 370 20
ø10 (8x) 80x50-3-2.5 2880 39 25 50 14.6 12.4 272 8.8
2880 44 30 50 17.3 18.1 398 15.7
9

4320 73 25 50 16.2 14.1 309 10.6


N 4320 84 30 50 19.1 21.8 477 21.2
C
H

5760 113 25 50 16.4 16.2 356 13.2


5760 131 30 50 20.2 24.5 538 25.9
100x50-3-2.5 3600 40 25 50 14.3 16.3 356 15.1
9

Drain
3600 45 30 50 16.9 23.6 517 28
35

R½"
5400 74 25 50 15.9 18.7 411 19
K M 5400 86 30 50 18.6 29.1 638 40.2
7200 116 25 50 16.7 21.4 470 23.8
7200 134 30 50 19.9 31.9 699 47
O
I

Refrigerant R 410A R 134A R 404A R 507A


Factor 1.01 0.93 1.00 0.97
O

330 Recalculation of the basic value with different refrigerants.


395
Accessories

DXRE Art. no. B H I O K M N S R C


400x200-3-2,5 7951 438 238 70 100 165 60 19 90 105 1/2"
500x250-3-2,5 7952 538 288 120 30 165 60 22 90 105 1/2"
500x300-3-2,5 7953 538 338 175 30 165 60 22 90 105 1/2"
600x300-3-2,5 7955 638 338 170 30 165 60 22 90 105 5/8"
600x350-3-2,5 7956 638 388 220 30 165 60 22 90 105 5/8"
700x400-3-2,5 7957 738 438 250 30 160 75 35 100 115 5/8"
800x500-3-2,5 7958 838 538 340 30 160 75 35 100 115 5/8"
1000x500-3-2,5 7959 1038 538 350 30 160 75 35 100 115 5/8"
406 | Accessories

VBR
Water-heating G
H F Thread G 1/4
battery
G Airing
Water-heating H Water out
battery for heating air in ventilation systems I Connection for
with rectangular ducts. Hot-zinc-coated cas- I immersion sensor
ing, heat transmission element with copper J Water in
tubes and aluminium fins. In cold conditions, K Draining
J
a frost protection device with sensor should
be fitted to reduce the risk of damage from K
freezing.

VBR Art. no. A c/c A B c/c B E kg


VBR XX-XX-2 = Two pipe rows
40-20-2 5463 438 420 238 220 R¾'' 5.5 kg
VBR XX-XX-4 = Four pipe rows
50-25-2 5464 538 520 288 270 R¾'' 7 kg
VBR XX-XX-3 = Three pipe rows
50-30-2 5465 538 520 338 320 R¾'' 8 kg
60-30-2 5466 638 620 338 320 R¾'' 9 kg
60-35-2 5467 638 620 388 370 R¾'' 10 kg
70-40-2 5468 738 720 438 420 R 1'' 12.5 kg
80-50-2 5469 838 820 538 520 R 1'' 16 kg
100-50-2 5470 1038 1020 538 520 R 1'' 18.5 kg

A c/c A B c/c B E kg
40-20-4 5471 438 420 238 220 R¾'' 7 kg
50-25-4 5472 538 520 288 270 R¾'' 9 kg
50-30-4 5473 538 520 338 320 R 1'' 10.5 kg
60-30-4 5474 638 620 338 320 R 1'' 11.5 kg
60-35-4 5475 638 620 388 370 R 1'' 13 kg

A c/c A B c/c B E kg
70-40-3 5476 738 720 438 420 R 1'' 15.5 kg
80-50-3 5477 838 820 538 520 R 1'' 19 kg
100-50-3 5478 1038 1020 538 520 R 1'' 22.5 kg

Max. operating temperature 150°C


Max. operating pressure, at water temp. 100°C 16 bar
Max. operating pressure, at water temp. 150°C 10 bar
Accessories
Accessories | 407

Coil calculation
Air Water
VBR Water temp. (in/out) Flow Pressure drop ΔT Capacity Flow Pressure drop
(°C) (m3/h) (Pa) (K) (kW) (l/s) (kPa)
40-20-2 60/40 400 9 18.5 2.7 0.03 0.5
1000 48 12.7 4.6 0.06 1
40-20-4 400 18 29.5 4.3 0.05 0.5
1000 96 19.5 7.1 0.09 0.5
40-20-2 80/60 400 9 32.8 4.7 0.06 1
1000 48 24.5 8.9 0.11 2
40-20-4 400 18 46.3 6.7 0.08 0.5
1000 96 38.9 14.0 0.17 1
50-25-2 60/40 600 8 21.7 4.7 0.06 1
1200 29 18.2 7.9 0.10 2
50-25-4 600 16 33.1 7.2 0.09 0.5
1200 59 28.4 12.3 0.15 1
50-25-2 80/60 600 8 36.5 7.9 0.10 2
1200 29 28.6 12.4 0.15 4
50-25-4 600 16 54.5 11.8 0.14 1
1200 59 45.9 19.9 0.24 3
50-30-2 60/40 800 10 18.2 5.3 0.06 0.5
2000 54 13.5 9.8 0.12 1
50-30-4 800 20 32.5 9.4 0.11 1
2000 109 27.2 19.7 0.24 2
50-30-2 80/60 800 10 33.6 9.7 0.12 1
2000 54 24.3 17.5 0.21 2
50-30-4 800 20 53.8 15.5 0.19 1
2000 109 41.7 30.1 0.37 4
60-30-2 60/40 1000 11 19.2 6.9 0.08 1
2500 58 15.4 13.9 0.17 2
60-30-4 1000 22 34.1 12.3 0.15 1
2500 117 28.2 25.5 0.31 4
60-30-2 80/60 1000 11 34.3 12.4 0.15 1
2500 58 24.4 22.1 0.27 4
60-30-4 1000 22 53.9 19.5 0.24 2
2500 117 41.8 37.8 0.46 7
60-35-2 60/40 1200 11 18.7 8.1 0.10 0.5
3000 61 15.0 16.3 0.20 2
60-35-4 1200 23 34.2 14.8 0.18 1
3000 123 28.1 30.4 0.37 4
60-35-2 80/60 1200 11 33.9 14.7 0.18 1
3000 61 24.1 26.1 0.32 3
60-35-4 1200 23 53.6 23.2 0.28 3
3000 123 41.5 45.0 0.55 8
70-40-2 60/40 2000 31 20.1 14.5 0.18 1
4000 94 16.0 23.2 0.28 1
70-40-3 2000 46 24.7 17.8 0.22 0.5
4000 139 21.1 30.5 0.37 1
70-40-2 80/60 2000 31 34.7 25.1 0.31 1
4000 94 25.1 36.3 0.44 3
70-40-3 2000 46 45.4 32.8 0.40 1
4000 139 34.4 49.7 0.61 2
80-50-2 60/40 2500 25 21.1 19.0 0.23 0.5
5000 77 17.2 31.1 0.38 1
80-50-3 2500 37 28.0 25.3 0.31 0.5
5000 113 24.0 43.4 0.52 1
80-50-2 80/60 2500 25 36.8 33.3 0.41 1
5000 77 26.9 48.6 0.59 2
Accessories

80-50-3 2500 37 48.4 43.7 0.53 1


5000 113 37.1 67.0 0.82 2
100-50-2 60/40 3000 23 24.8 26.9 0.32 1
6000 72 18.4 40.0 0.48 2
100-50-3 3000 35 32.3 35.0 0.42 1
6000 106 25.6 55.4 0.67 2
100-50-2 80/60 3000 23 38.4 41.6 0.51 2
6000 72 28.2 61.1 0.75 4
100-50-3 3000 35 50.1 54.3 0.66 2
6000 106 38.7 83.8 1.02 4
Data based on supply air temperature of 0°C.
408 | Accessories

VBK
Water-heat- Air

ing battery
for square
Connection for thermostat
ducts (frost protection device)
The casing is
manufactured from galvanized steel, the
heat transmission elements are copper
tubes with aluminium fins, and with copper
pipes for connecting water inlet and outlet. If
Draining
the VBK is to be used in very cold conditions
it may be necessary to install a frost protec-
tion device.
The VBK is designed for horizontal mount-
ing with the water connection to the right.
For best results the air and water must be VBK Art. no. £A c/c £D no. of rows
going through the battery in opposit direc- 45 6169 492 470 78 2
tions. The water must be flowing upwards in 50 6160 547 520 78 2
order to facilitate airing of the battery. Soft- 55 6174 595 573 98 2
ware for determining the required dimen- 65 6179 707 680 98 2
sions for the desired output is available.

Air

Water

The air flow should be going in the opposite


direction of the water.

Coil calculation
Water temp Air Pressure drop DT Capacity Water Pressure drop
VBK in/out flow [Pa] [°C] [kW] flow [kPa]
[m3/h] [l/s]
45 60/40°C 1000 10 30.1 10.2 0.12 0.8
2000 38 23 15.6 0.19 1.7
2500 57 20.9 17.7 0.21 2.2
80/60°C 1000 11 44.7 15.1 0.18 1.5
2000 38 34.5 23.4 0.28 3.4
2500 58 31.5 26.7 0.32 4.3
50 60/40°C 1200 10 31.5 12.8 0.15 1.4
2400 35 24.2 19.7 0.23 3.1
3000 53 22 22.4 0.27 3.9
80/60°C 1200 10 46.1 18.8 0.22 2.6
2400 36 35.8 29.1 0.35 5.8
3000 54 32.7 33.3 0.40 7.4
55 60/40°C 2000 18 26.1 17.8 0.21 0.7
4000 64 19.5 26.5 0,32 1.4
Accessories

5000 96 17.7 29.9 0,36 1.7


80/60°C 2000 18 39.5 26.8 0.32 1.3
4000 65 29.9 40.6 0.48 2.8
5000 98 27.2 46.1 0.55 3.5
65 60/40°C 3600 27 24.6 30 0.36 1.5
7200 99 18.2 44.5 0.53 3
9000 150 16.5 50.2 0.60 3.7
80/60°C 3600 28 36.8 49 54 2.8
7200 101 27.7 67.6 0.81 5.9
9000 152 25.1 76.5 0.91 7.3
Data based on supply air temperature of 0°C
Accessories | 409

LDK Noise suppression dB frequency band Hz Pressure drop

LDK 125 250 500 1k 2k 4k 8k


Silencer for square
45 5 8 13 12 8 7 7
ducts
50 7 8 13 12 9 8 7
LDK is easily connected to our square duct 55 9 9 13 12 10 9 8
fans type KDRE and KDRD.
65 6 7 14 13 9 8 7
Noise reduction can be determined by us-
70 5 7 19 24 23 15 10
ing the table provided.

LDK Art. no. £b £B C D LDK Art. no. £b £B C D E F


45 5114 450 490 50 100 65 5117 661 703 50 100 93 175
50 5115 502 546 50 150 70 5118 696 740 50 100 110 176
55 5116 550 594 50 200

FFS Pressure drop

Filter cassette for


square ducts
Filter cassette with
a bag filter standard
type M5 included. The cassette is manufac-
tured from galvanized steel with a hinged
cover underneath and fitted with a quick-re-
lease latch for easy change of filter. It can be
connected directly to the duct. Connections
for a pressure sensor are standard. The rec-
ommended final pressure drop is 200 Pa. FFS Art. no. £A c/c £B C
45 5080 447 470 492 502
50 5081 502 520 547 532
55 5082 550 573 595 562
65 5083 661 680 707 642
70 5084 697 720 742 642
Filter cassette Bag filter Filter media
(incl. in FFS)
FFS 45 BFS 45 M5
FFS 50 BFS 50 M5
FFS 55 BFS 55 M5
FFS 65 BFS 65 M5
FFS 70 BFS 70 M5
Accessories
410 | Accessories

RBK RBK
Power kW 17
45/17 50/21
21
Electric duct Voltage V 400 400
heater for square Phase ~ 3 3
ducts Current A 24.5 30
Casing manufactured Min. airflow m3/h 570 910
from alu-zink coated sheet metal with heat-
55/33 66/39
ing elements in stainless steel. The heater
Power kW 33 39
has built-in overheating protection with
Voltage V 400 400
manual reset. Heat control by means of a
controller TTC together with a TT-Slave (TT- Phase ~ 3 3
S1) or TTC together with a TT-M Slave. Min. Current A 48 56
airflow is based on a min.air velocity of 1.5 Min. airflow m3/h 890 1650
m/s. The duct heater is dimensioned for a
maximum outgoing temp. of 40°C.
Calculation of required power
RBK Art. no. £B D P = qv x air density x delta t
45 5446 450 370
50 5447 500 370
P = power (kW)
qv = air volume (m3/s)
55 5448 550 370
air density = 1.2 kg/m3 at 20°C
65 5449 660 370
delta t= temperature difference

RED
Reducer
Pressed, concentric reducer
with female coupling, with
a 45° angle. This reducer is
designed to meet demands for short instal-
lation lengths with low pressure drop and
low internal noise generation.

ø150
Accessories

48

ø160

F1 = overheat protection, automatic reset (70°C)


F2 = overheat protection, manual reset (120°C)
Accessories | 411

EFD The connection ends are equipped with


silicon rubber sealing rings. The damper is
Pressure drop
100
Single blade made from hot-dip galvanized sheet steel. EFD

ps [Pa]
circular damper The EFD turn off damper is prepared for 50
40
external insulation and has arrows showing
Circular damper EFD is 30
the damper blade position.
a shut-off damper. The 20
We recommend preventive maintenance
damper is provided with
of the damper twice per year for optimum
24V AC motors with 10
performance. If the damper gets dirty, the
spring-return actuators. EFD are made in
blade should be cleaned. The gasket sealing
leakage performance class 3 according to EN 5
should be checked and the blade axle lubri- 4
1751:1998 Annex C.2. Outdoor/exhaust air
cated as necessary. 3
damper have the function to prevent the hot
2
water battery to freeze. EFD connects to a
connection block inside the electrical box.
1
The EFD consists of a tubular housing 1 2 3 4 5 10
m/s
equipped with a damper blade pivoting on
an axle. The blade fits into the circular duct.

EFD 160-315 EFD 400-630


100

B
10
øA

10

C
C C
B

B
ød H

EFD Art. no. øA B C


160 7122 160 175 45 EFD Art. no. ød A B C H
200 203914 200 175 45 400 9859 400 255 25 221 70
250 203915 250 175 45 500 4746 500 255 25 221 70
315 204309 315 175 45 630 4747 255 255 25 221 70

EFD A 20 EFD Art. no. A B


40-20 6904 400 200
Opposed blade
50-25 6905 500 250
damper for 50-30 7780 500 300
rectangular ducts 60-30 6906 600 300
B

EFD is a shut-off damper. The damper is 60-40 6907 600 400


provided with a 24 V motor and with spring- 70-30 6912 700 300
return actuators. EFD is manufactured to 50 70 140 70-40 6908 700 400
leakage performance class 3 according to
80-35 6913 800 350
EN 1751:1998 Annex C.2. Outdoor/exhaust
80-40 6909 800 400
air damper has the function to prevent the
hot water battery from freezing and also 100-35 6914 1000 350
Pressure drop
prevent the cold air from cooling down the
building should the unit stop functioning.
The EFD multi-leaf damper comprises of
a number of opposed blades, swivelling on
nylon bearings in a sheet metal framework.
Accessories

The blades are connected via a system of


linkages (protected) on the outside of the
frame. Maximum air temperature is 100°C.
412 | Accessories

VK Pressure drop

Louvre shutter

Ps [pa]
Louvre shutters for ver-
VK
tical mounting on a wall.
The profiled vanes pro- A
F
duce a strong upward

B
force which reduces the air resistance. This
means that the vanes opens fully at low air
C
velocities as well. All the parts are manu-

D
factured in weather-resistant and shock-

H
E
proof nylon material (PVC containing special
synthetic). The robust construction ensures G

that the blades will not become deformed or I


loose. Air velocity should not exceed 12 m/s.
The louvre shutters are easy to install. Wall Air velocity in duct m/s
plugs and screws are included.

VK Art. no. A B C D E F G H I J*
40-20 5644 455 15 452 255 215 415 - 285 485 44
50-25 5647 555 15 552 305 265 515 - 335 585 44
50-30 5648 555 15 552 355 315 515 - 385 585 44
60-30 5649 655 15 2x309 355 315 615 30 385 685 44
60-35 5650 655 15 2x309 405 365 615 30 435 685 44
70-40 5652 755 15 2x359 455 415 715 30 485 785 44
80-50 5655 846 15 2x405 555 515 806 30 585 876 44
100-50 5637 1146 15 2x560 555 506 1097 28 585 1176 42
*J = thickness of frame

SDM SDM Art. no. l1


025 32571
l2
417 327 417 327 40
b1 b2 h1 h2
42
Service door 042 32572 587 497 587 497 40 42
h2

For Multibox (MUB) 062 32573 717 627 717 627 40 42


b1
b2

or Thermo-Box
(MUB-T). The casing
consists of an galvanized steel panels, dou-
ble skin frame with a 20 mm mineral wool
insulation. Including four quicklocks, hand-
hold and key. l2 h1
l1

EGS 80 * Mounting for REV

Protection guard EGS Art. no. b1 b2 C I h


80
68

Weather and 025 311696 80 80 258 418 17


68
protection guard EGS 042 301345 114 114 360 588 17
for Multibox MUB/T 062 301346 179 179 360 718 17
size 025/042/062.
Mounting at motor side. The guard is d1
Accessories

8x
manufactured from galvanized steel. Includes
reference points for REV ON-OFF isolator.
b1 C b2 h
l
Accessories | 413

WSD WSG UGS


Weather roof Weather protectionB Flexible adapter,
for Multiboxes guard for Multiboxes square to circular

40
Manufactured from seawater resistant alu- Manufactured
40 from galva- Reduction from square
minium. Edges are welded. nized steel. The protection to round. The frame is manufactured from
A guard includes a protection grille. Suitable aluminium and neoprene coated fabric. For

A
B for MUB Multiboxes. temperature up to 60°C. The circular side
has a locking ring for easy installation to the
A
C duct system.
4)
(x
.5

Suitable for MUB and K.. airhandling units.


ø8

B
7

40

39
40
38

Protection guard
A
WSD Art. no. A B C

39
025 300688 560 480 260
62
042 300689 730 650 370 7
062 300690 860 780 500
WSG Art. no. A B
39

100 300691 1060 980 700


025 4361 418 418
042 4362 585 585
UGS Art. no. A/C G/H I J
062 4363 715 715
025/315 31290 378 418 315 210
100 4364 915 915
025/355 4356 378 418 355 210
39

62 025/400 31291 378 418 400 210


042/355 32850 548 588 355 210

FGV
042/400 32851 548 588 400 210
042/500 4357 548 588 500 210
Flexible connection 062/500 32852 678 718 500 210

SRKG
Manufactured from alu- 062/630 4358 678 718 630 210
minium with neoprene
coated fabric. For temperature up to 60°C. Shutter for Multibox
On both sides there are holes for mounting SRKG is a cut-off shutter
to the duct system. Suitable for MUB. intended for use in ventila-
tion systems. The shutter is designed with a
number of blades which close towards each
CCM
other, mounted in an aluminium frame. The Inlet connection MUB
blades are manufactured from aluminium. Reduction from square to
round for easy connection of
accessories on the inlet side.
20
The CCM is manufactured from galvanized
12

9
steel. The circular side has a double seal for
15

90
easy installation to the duct system.
This accessory should be pre-assembled
c/c D
B

ex factory to the selected fan.

FGV Art. no. A B C D A 120


025 4196 418 398 378 190 c/c C
042 4605 586 568 548 350
062 4198 718 698 678 418
n da
n di

SRKG Art. no. A B c/c C c/c D


100 4199 918 898 878 400
025 4268 378 378 398 398
042 4868 548 548 568 568
062 4870 678 678 698 698
Accessories

100 4871 878 878 898 898 h

CCM Art. no. ødi øda h


400 311780 400 440 75 MUB042
500 311781 500 540 75 MUB042
560 311782 560 600 75 MUB062
630 311783 630 670 75 MUB062
414 | Accessories

CCM DSK ASF/KB


Circular connection, Flexible connections Flexible connection
outlet MUB Flexible connections for KDRE The ASF/KB is manufac-
Reduction from square to round for easy and KDRD. The connections to tured from galvanized
connection of accessories on the outlet side. the fan are easily bolted to fan steel, with neoprene
The CCM is manufactured from galvanized and duct. coated fabric. It can be used for tempera-
steel. The circular side has a double seal for tures up to 120°C. The ASF/KB has double
easy installation to the duct system. sealing on each side. Suitable for KBT/KBR.

5

20

B
Ød

I

DSK Art. no. A B C


45 5100 492 447 120 ASF Art. no. øda h
1.5
50 5102 547 502 120 200/KB 2714 200 196
55 5103 595 550 120 225/KB 2715 225 199
CCM Art. no. ød I
65 5104 707 661 120 250/KB 2716 250 200
400 311682 400 588 MUB042
70 5105 742 696 120 280/KB 2717 280 200
500 311683 500 588 MUB042
560 311684 560 718 MUB062 315/KB 2718 315 205

630 311681 630 718 MUB062 355/KB 2719 355 210

WSD-KBT
CCMI
Weather roof for
motor
WBK
Wall mounting
Circular connection Additional weather pro-
tection for the motor of
bracket
insulated, outlet MUB
thermo fans KBT and KBR, if mounted out- For mounting the KBT/KBR close to the wall.
Reduction from square to round for easy Manufactured from galvanized steel. The cor-
side. Manufactured from seawater resistant
connection of accessories on the outlet side. ners are welded. Available in pairs. Suitable
aluminium.
The CCMI double skin panel with 20mm for KBT/KBR.
mineral wool insulation is manufactured Art. no. 2720 (KBT), 2721 (KBR)
A
from galvanized steel. The circular side has 400
60
double sealing for easy installation of the
duct system.

25
45

Ø5
8x
181

2 x (13 x 16)

250
180

25
Ød

I

300 )
126 126 ,2
(x7
UGF
20

ø4

Counter flange
20 Counterflange for connec-
200

tion to a duct system.


CCMI Art. no. ød I Manufactured from galva-
10
60

400 311562 400 588 MUB042 nized steel.


500 311565 500 588 MUB042
560 311563 560 718 MUB062
630 311564 630 718 MUB062 WSD- Art. no. A
Accessories

KBT
1 2728 265 KBT 160 - 180,
KBR 315/355 4-pole
2 2729 385 KBT 200 - 280,
KBR 315/355 2-pole
ALS-KBT
Drain for liquids that
UGF Art. no. øA ø da ø LK
accumulate in the casing.
280 305492 279,5 390 356
For KBT/KBR. Accessory to be ordered to-
315 305493 314,5 390 356
gether with the fan, to be assembled in the
factory. 355 305494 354,5 428 395
Art. no. 2727
Accessories | 415

ASF ASS
Inlet flange Flexible connection
Counterflange for con- Manufactured from gal-
nection to a duct system. vanized sheet steel, with
Manufactured from galvanized steel. Suit- neoprene coated fabric.
able for DVS/DVSI, DHS, DVN/DVNI up to For temperature up to 70°C. Suitable for
120°C. DVS/DHS, DVSI, DVN, DVNI, DVC, DVCI, TFSK.

ASS Art. no. øda øe ødi h3 zxd


190/225 9573 235 213 183 155 6xø7
310/311 9575 306 285 256 155 6xø7
355-500 9576 464 438 402 155 6xø9
560/630 9577 639 605 569 155 8xø9
710 9578 710 674 634 155 8xø9

TDA DV

h
ASF Art. no. ø da ø e ø di h2 z x d Adapter 4xøi
190/225 9567 235 213 183 25 6 x ø7
Adapter frame for
310/311 9568 306 285 256 25 6 x ø7
mounting of accessories. Adapter frame TDA
355/500 9569 464 438 402 30 6 x ø9 for mounting into roof socket. Manufactured d
560/630 9570 639 605 569 30 6 x ø9 nxø
from galvanized steel.
ød1

D
E
F
710 9571 708 674 634 30 6 x ø9 ød
800/900 9572 910 872 797 32 6 x ø10 e

FTG
Tilting device for TDA DV Art. no. D E F h øi nxød øde ød1
roof fans 190/225 309416 226 245 294 19 10 6x6.5 183 213
310/311 301392 300 330 373 19 10 6x6.5 256 285
The tilting device FTG
is for the additional 355/400 301393 450 464 543 20 12 6x9 405 438
mounting of the roof fans DVS/DVSI/DVC/ 450/500 301394 486 535 619 35 12 6x9 405 438
DHS/DVN and DVG/120°C. With the tilt- 560/630 304815 650 750 793 15 14 8x9 570 605
ing device FTG the roof fan is easy to open
for service options. The open fan can be
secured against unintended closing. The
framework consists of galvanized steel
and the hinges are made of stainless steel.
For the connection of inlet accessories the
adapter framework TDA is needed, which BTG
has to be ordered separately. The delivery
includes mounting material. The tilting de- Back draft
vice is available for the sizes 310 up to 630. damper
Back draft damper
designed for the TG
300-800, TG 400-
500, TG 400-800
and TG roof curbs, which can be fitted as
long as the roof curb is installed vertically.
The frame and damper vanes are manu-
factured from galvanized sheet steel. The
Accessories

frame is screwed or riveted on to the roof


curb’s perforated inner casing.

FTG 355/400 also suitable for DVG 315/120 and


355/120 / FTG 450/500 also suitable for DVG
400/120 and 450/120

FTG Art. no. A B C


310/311 30507 420 330 304
355/400 30508 580 450 466
450/500 30248 650 535 490
560/630 30509 924 750 654
416 | Accessories

TOB TOS THB


Profiled roof Flat roof cover- Profiled roof
covering ing plate cowl
plate The covering plate is This cowl is
This covering fitted at right angles shaped so as to
plate is shaped to the roof cladding fit over a stand-
like a roof tile so that it can be fitted on and can therefore be ard double-lap
to a standard double-lap concrete roof tile used on different roof pitches. concrete roof tile (THB 160), or over two
(type TOB 125-160) or on to two single-lap The covering plate is manufactured from tiles (THB 200). The cowl is fitted at right
roof tiles (TOB 200-315). It is fitted at right powder-coated galvanized sheet steel. They angles to the roof cladding and can there-
angles to the roof cladding and can there- are available in the standard colours of fore be used on different roof pitches.
fore be used on different roof pitches. black, brick red and also uncoated. The spiral Manufactured from powder-coated, gal-
The covering plate is manufactured from pipe connected to the cover is insulated with vanized sheet steel, in the standard colours
powder-coated galvanized sheet steel. They 30 mm mineral fibre. The roof fan TFSR is of black and brick red. The spiral pipe con-
are available in the standard colours of fastened to the profiling plate with 4 screws, nected to the cover is insulated with 30 mm
black, brick red and also uncoated. The spiral these screws are included in TOS. rockwool matting. The TUB under-plate, for
duct connected to the cover is insulated with 3 m cable is included, as well as the TUS fitting inside the roof, is included. This under-
30 mm mineral fibre. The roof fan TFSR is under-plate which is fitted on to the in- plate prevents water-damage via the roof
fastened to the profiling plate with 4 screws, side of the roof. This under-plate prevents aperture if there is leakage on the outside of
these screws are included in TOB. water-damage via the roof aperture if there the roof. The under-plate should not be used
3 m cable is included, as well as the TUB is leakage on the outside of the roof. The if the roof is only covered with roofing felt.
under-plate which is fitted on to the inside underplate should not be used if the roof is
of the roof. This under-plate prevents water- only covered with roofing felt.
damage via the roof aperture if there is

G
leakage on the outside of the roof.
The underplate should not be used if the

F
roof is only covered with roofing felt. F

E
E
F

øD

øD
E

øD

D
C
B
D
C

A
B
A

B
THB Art. no. A B C D
TOS Art. no. A B E F øD
160 1764 260 375 448 448
TOB Art. no. A B C D 125-160 1533 455 480 323 230 160
200 1767 560 684 430 500
125-160 1411 260 375 – 448 200-315 1658 585 735 326 138 200
200-315 1450 560 684 430 500 THB Art. no. E F G øD
160 1764 323 230 72 160
TOB Art. no. E F øD
200 1767 326 138 76 200
125-160 1411 323 230 160
200-315 1450 326 138 200
Accessories

TUB/TUS
Roof sealing plate
for TOB or TOS.
Accessories | 417

THS TG 300-800, TG
Flat roof cowl 400-800 Roof curb
The cowl is fitted at right The brackets make it easy to
angles to the roof cladding
Roof curb fit the roof curb to the roof
and can therefore be used The brackets make it easy pitch, and also function as a
on different roof pitches. to fit the roof curb to the silencer. Manufactured from
Manufactured from powder-coated, galva- roof pitch. TG also has a galvanized sheet steel and
nized sheet steel, in the standard colours silencer function. Manufac- insulated with a 50 mm rock-
of black and brick red. The spiral pipe con- tured from galvanized sheet steel and insu- wool sheet and a perforated inner plate.
nected to the cover is insulated with 30 mm lated with a 50 mm rockwool sheet and a The roof curb is fitted with plastic piping
rockwool. The TUS under-plate, for fitting perforated inner plate. and conduits for electric cables.
inside the roof, is included. This underplate The roof curb is fitted with plastic piping A roof curb with 100 mm insulation (cor-
prevents water-damage via the roof aper- and conduits for electric cables. Weight 24 kg. responding to A60 insulation) is available on
ture if there is leakage on the outside of the B request. B
C inv.
roof. The under-plate should not be used if C inv.

the roof is only covered with roofing felt.


G

A
F

min. 68
E

min. 68
D inv.

øD D inv.
B

c/c E

c/c E
TG Art. no. A B C D E
300-800 5924 800 293 183 289 245 TG Art. no. A B C D E
400-800 1718 800 393 283 389 330 540-800 1727 800 494 378 490 450
A
Hole measurement in roof = B+10 mm 640-800 1729 800 594 478 590 535
540-1230 1726 1230 494 378 490 450
640-1230 1728 1230 594 478 590 535
THS Art. no. A B E F G øD
1140-800 5085 800 1094 - 1040 -
160 1839 455 480 323 230 72 160
Hole measurement in roof = B+10 mm
200 1848 585 735 326 138 76 200
STG
B
Roof base plate
Accessory for the TG 400-800. Adapter for
98

connection with ø125, 160 and 200 mm.


A

80

c/c C
c/c D
Accessories

øA

STG øA TG Art. no. A B C D


125 125 740-1200 5088 1200 694 655 590
160 160 940-1200 5090 1200 894 840 750
200 200 Hole measurement in roof = B + 10 mm
418 | Accessories

ASK, ASK/F,
ASG/F
Connection box
ASK, ASK/F and ASG/F for mounted on sock-
et silencers to fix inlet accessories or ducts.
ASK made of seawater resistant aluminium.
L
For DVS/DHS, DVSI, DVNI, DVN, DVC, TOE,
TOV.

ASK Art. no. A øD øE øF øG H I K L kg


ASK/F made of aluzinc steel. For DVV and
DVV/F. 225 300902 290 213 183 6xM6 4xø7 272 114 - 110 0.9
310/311 300904 391 285 256 6xM6 4xø9 366 152 - 110 1.2
ASG/F made of aluzinc steel. For DVG. 315 TFSK 309229 474 285 256 6xM6 4xø9 449 179 - 110 2
355/400 300905 551 438 402 6xM8 4xø9 526 214 - 110 2
450/500 300907 621 438 402 6xM8 4xø9 596 241 - 110 2.2
560/630 300908 889 605 569 8xM8 4xø9 866 471 235,5 110 3.9
710 300910 981 674 634 8xM8 6xø9 956 508 254 110 5

ASK/F Art. no. A øD øE øF øG H I nxK L kg


400 305203 522 356 322 8xM8 10 496 250 2x125 200 6
450 305204 672 395 360 8xM8 10 646 320 2x160 250 10
560 305205 672 438 404 12xM8 10 646 320 2x160 250 10
630 305206 962 541 507 12xM8 10 936 640 4x160 300 19
800 305207 962 674 636 16xM10 10 936 640 4x160 350 19
1000 305208 1105 751 713 16xM10 10 1079 720 4x180 350 24

ASG/F Art. no. A øD øE øF øG H I K L kg


315-355 309948 - 545 438 402 6xM8 4xø9 526 214 - 200 5
400-450 309949 - 615 438 402 6xM8 4xø9 596 241 - 200 5
500-560 309950 - 885 605 569 8xM8 6xø9 866 471 235,5 250 13
pitch ø 1 674 8xM8
630* 309951 975 634 6xø9 956 508 254 300 17
pitch ø 2 (Eurovent) 690 12xM10
pitch ø 1 872 8xM8
800/1000* 95215 1205 800 6xø9 1174 640 320 300 22
pitch ø 2 (Eurovent) 860 16xM10
* 2 pitch diameters, same part

FDG/F F
E F
E
Flat roof socket
Flat roof socket
h6

FDG/F is made of 10

h6

aluzinc steel supplied with 40 mm mineral


wool insulation with coated fabric. Addi- C
tional guard for insulation protection. For use
up to 400°C medium temperature. Inclusive H D

sealing between fan and socket. Suitable for


D nut M
DVG-H, DVG-V, sizes 630 and 800 also for
DVV-XS/XL.
nut M

G G
Accessories

FDG/F Art. no. C D E F G H h6 nut M kg


315-355 309940 - 450 562 980 472 713 300 4xM10 17
400-450 309941 - 535 628 980 538 783 300 4xM10 20
500-560 309942 806 750 898 1200 808 - 300 4xM10 35
630 309943 896 840 990 1300 898 - 300 4xM10 39
800/1000 95211 1120 1050 1210 1540 1120 - 300 4xM12 45
Accessories | 419

SSD D
Roof unit socket E
4x Nut M1

silencer
Socket silencer for
sound reduction at the H

h7
inlet side. The sound absorption at 250 Hz is
on average 8 dB. The SSD is manufactured
from seawater resistant aluminium. The I

sound absorbing material is abrasion resist-


4x Nut M2 F
ant up to a velocity of 20 m/s. The baffles
can be taken out for maintenance works.
Suitable for DVS/DHS, DVSI, DVN, DVNI, DVC,
TFSK and DVEX. SSD Art. no. D E F H nut M1 nut M2 I h7 Pressure
drop no.
190/225* 9560 245 297 571 258 M6 M6 114 400 1
310/311** 9561 330 398 710 345 M6 M6 152 500 2
315M/L*** 30086 450 478 797 434 M10 M8 179 650 3
355/400 9562 450 562 874 472 M10 M8 214 650 3
450/499/500 9563 535 628 900 538 M10 M8 241 650 4
560/630 9564 750 898 1200 808 M10 M8 471 700 5
710 9565 840 990 1300 898 M10 M8 508 800 6
800/900 9566 1050 1212 1540 1118 M12 - - 1000 7
* also suitable for TFSK 125 M/L
** also suitable for TFSK 160 and 200
*** suitable only for TFSK 315 M/L

Pressure drop

SSD 190-500
Attenuation [dB]

SSD 560-900
Accessories

Frequency [Hz]
420 | Accessories

FDS F
Flat roof socket E
FDS is manufactured for DVS/DHS, DVSI, DVN, DVNI, DVC, DVEX.
from seawater resist- Supplied with washers and screws.
ant aluminium and is supplied ready for as-

h6
sembly with insulation up to 100°C. Suitable

10

FDS Art. no. D E F G H M h6 kg
190/225 9548 245 294 720 264 452 M6 300 3.5
310/311 9549 330 395 810 359 553 M6 300 4.5
315M/L, TFSK 30010 450 478.5 898 431 639 M10 300 5.0
H

355/400 9550 450 554 977 506 714 M10 300 6.5
D
450/499/500 9551 535 625 997 577 783 M10 300 8.0
560/630 9552 750 895 1350 847 1055 M10 300 10.5 M
710 9553 840 985 1450 937 1143 M10 300 12.0
800/900 9554 1050 1205 1600 1157 1363 M12 300 27.0 G

FDV, FDV/F, A1


A2

FDV-EX M

Flat roof socket


for DVV/120, DVV/F, DVV-EX

350
The flat roof socket FDV is manufactured
from aluzinc steel supplied with 40 mm min-
eral wool insulation with coated fabric. The E
insulation of FDV/F and FDV-EX is secured 4xM8
G
with an additional metallic guard. The seal-
ing between fan and socket is provided. B

FDV-EX with extra bolt for earthing.

FDV / FDV/F Art. no. Art. no. FDV-EX A1 A2 B M E G kg


400 3687 / 3692 - 535 460 720 12 444 496 17/19
450/560 3693 / 3422 95291 685 600 870 12 594 646 21/24
630 3689 / 3695 95292 975 880 1160 16 879 936 41/45
800 3690 / 3696 95292 975 880 1160 16 879 936 41/45
1000 3691 / 3697 95293 1120 1040 1400 16 1023 1079 52/63

FDVE, FDVE/F,
FDVE-EX
Roof socket for
DVV/120, DVV/F,
DVV-EX
Flat or inclined roof socket up to 20° incli-
nation. Manufactured from aluzinc steel,
supplied with 40 mm mineral wool insulation
with coated fabric. The insulation of FDVE/F
Accessories

and FDVE-EX is secured with an additional


metallic guard. The sealing between fan and
socket is provided. Profiles adjustable up to
20°, to be adjusted to inclination of the roof
at site. FDVE-EX with extra bolt for earthing.

FDVE Art. no. Art. no. FDVE-EX A1 A2 E G H M kg


400 3675 / 3681 - 535 460 447 496 750 12 32/37
450/560 3676 / 3682 95294 685 600 597 646 800 12 41/47
630/800 3678 /3685 95295 975 880 884 936 900 16 73/86
1000 3680 / 3686 95296 1120 1040 1029 1079 950 16 92/105
Accessories | 421

LGV/LGH 1 2 3 4 5 6 7

Roof cowl 1000

The roof cowl LGV/LGH 500


as supply or exhaust

Pressure drop in Pa
300
cowl. Empty (no motor impeller) casing of
200
model DVS/DHS/DVN roof fans. Dimensions
are equivalent to the size of the roof fans.
100

50

LGV Art. no. Pressure drop charac-


20
teristic curve no.
200 500 1000 5000 10000 40000
190/225 8505 1 Air volume in duct m³/h
310/311 8506 2
355/400 8507 3
450/499/500 8508 4 1 2 3 4 5 6 7
560/630 8509 5 1000
710 8510 6
800/900 8783 7 500

Pressure drop in Pa
300
200

100
LGH Art. no. Pressure drop charac-
teristic curve no.
50
190/225 8511 1
310/311 8512 2
20
355/400 8513 3 200 500 1000 5000 10000 40000
450/499/500 8514 4 Air volume in duct m³/h
560/630 8515 5
710 8516 6 1 2 3 4 5 6
1000

500
Pressure drop in Pa

300
200

100

50

20
200 500 1000 5000 10000 40000
Air volume in duct m³/h

1 2 3 4 5 6
1000

500
Pressure drop in Pa

300
200

100

50
Accessories

20
200 500 1000 5000 10000 40000
Air volume in duct m³/h
422 | Accessories

SSVE,
SSVE/F,
SSVE-EX
Roof socket silencer
for DVV/120, DVV/F, DVV-EX
The socket silencers are suitable for pitched
roof constructions up to a max. angle of 20°.
Angle can be adjusted on the silencer.
Casing manufactured from aluzinc steel,
insulation/baffles of mineral wool with a
textile lining. For versions .../F (smoke ex-
tract) and EX the baffles are secured with an
additional metallic guard. The surface of the
baffles is abrasion resistant. Silencers come
complete with nuts at the bottom to fix
further inlet-side accessories. Supplied with SSVE Art. no. £A1 £A2 M £E £G H kg
sealing between socket and fan. SSVE-EX 400 3769 535 460 12 447 496 750 35
with extra bolt for earthing 450/560 3770 685 600 12 597 646 800 48
630/800 3772 975 880 16 884 936 900 90
Attention! Automatic shutters VKVE/F, VKV/F 1000 3774 1120 1040 16 1029 1079 950 111
can only be installed into the L-version si-
lencer (on request). Automatic shutter for SSVE/F Art. no. Art. no. SSVE-EX £A1 £A2 M £E £G H kg
DVV-Ex cannot be installed into SSVE-EX. 400 4410 - 535 460 12 447 496 750 43
450/560 4411 95300 685 600 12 597 646 800 59
630/800 4413 95301 975 880 16 884 936 900 108
1000 4415 95302 1120 1040 16 1029 1079 950 133

Pressure drop
Pressure drop dp [Pa]

Noise reduction
Noise reduction [dB]
Accessories

Frequency [Hz]
Accessories | 423

SSG, E

SSG/F
Roof socket
silencer for

H
DVG
The socket silencers SSG/F are suitable for
mounting on flat roofs. Casing made from
aluzinc steel, insulation/baffles of mineral
wool with textile lining. 40 mm insulation, in C
.../F version with additional metallic protec- F
tion guard. The sound absorption at 250 Hz D
nxM
is on average 8 dB. Silencers come complete
with nuts at the bottom to fix further inlet
G
side accessories. Supplied with appropriate
sealing between socket and fan. Suitable for
DVG-H, DVG-V fans, sizes 630 and 800/1000
also for DVV-XS/XL 120° respectively DVV/F-
XS/XL fans. SSG / SSG/F Art. no. C D E F G M h7 kg
315/355 -/309944 468 450 562 874 472 4xM10 650 41
400/450 -/309945 534 535 628 900 538 4xM10 650 46
500/560 -/309946 806 750 898 1147 808 4xM10 700 72
630 95337/309947 894 840 990 1300 898 4xM10 800 90
800/1000 95338/95217 1120 1050 1210 1540 1120 4xM12 1010 115

Pressure drop
100

SSG/F - SSGE/F
Pressure drop (Pa)

315 - 355 400 - 450 500 - 560 630 800

10
1000 10000
Air volume (m3/h)

Sound attenuation
20
SSG/F
18

16

14
315-355 500-560
12 400-450 630
Accessories

800
[dB A]

10

0
125 250 500 1000 2000 4000
[Hz]
424 | Accessories

SSGE, SSGE/F SSGE 315-630 SSGE 800


A1 A2 A2
Roof socket silencer nxM
for DVG

HF
HF
H1
H2

~750
Sizes 630 and 800/1000

H3
also for DVV-XS/XL.

1200
The socket silencers sizes up to 630 are suit-
max 30° max 20°

HK

HK
able for pitched roof constructions up to a
max. angle of 30°. Size 800/1000 for up to
20°. Angle can be adjusted in 3 positions.

300

160
SSGE silencers 630 and 800/1000 for DVV-
XS/XL/120. A3 C C
4xM8
Casing manufactured from aluzinc steel,
insulation/baffles of mineral wool
with a textile lining. The baffles are secured
SSGE Art. no. A1 A2 A3 C H1 H2 H3 HK HF nxM kg
with an additional metallic guard (F version).
The surface of the baffles is abrasion resist- 630 95340 990 840 956 898 515 685 855 390 510 4xM10 83
ant. Supplied with sealing between socket 800/1000 95341 1210 1050 1174 1120 - - - 600 440 4xM12 127
and fan.
SSGE/F Art. no. A1 A2 A3 C H1 H2 H3 HK HF nxM kg
Diagram of pressure drop and noise reduction
315-355 95087 562 450 526 472 435 685 935 370 530 4xM10 50
on page 423.
400-450 95113 628 535 596 538 435 685 935 370 530 4xM10 55
500-560 95114 898 750 866 808 515 685 855 390 510 4xM10 86
630 95115 990 840 956 898 515 685 855 390 510 4xM10 98
800 95218 1210 1050 1174 1120 - - - 600 440 4xM12 135

FDGE, FDGE 315-630 FDGE 800

FDGE/F A1
nxM
A2 A2

Roof socket for DVG


H1

~7 5 0
Sizes 630 and 800/1000
H2
H3

also for DVV-XS/XL.


The roof sockets FDGE/F sizes up to 630 are
1200

max 30° max 20°


suitable for pitched roof constructions up to
a max. angle of 30°. Size 800/1000 for up
to 20°. Angle can be adjusted in 3 positions.
FDGE sockets 630 and 800/1000 for DVV-
XS/XL/120. A3 C C
4xM8
Casing manufactured from aluzinc steel.
Supplied with sealing between socket and
fan.
FDGE Art. no. A1 A2 A3 C H1 H2 H3 nxM kg
FDGE: insulated with 20 mm Armaflex XG.
FDGE/F: insulation of mineral wool with a 630 95334 990 840 956 898 515 685 855 4xM10 60
textile lining. Insulation is secured with an 800/1000 95335 1210 1050 1174 1120 - - - 4xM12 85
additional metallic guard. The surface of in-
sulation is abrasion resistant. FDGE/F Art. no. A1 A2 A3 C H1 H2 H3 nxM kg
315-355 95116 562 450 526 472 435 685 935 4xM10 43
400-450 95117 628 535 596 538 435 685 935 4xM10 48
500-560 95118 898 750 866 808 515 685 855 4xM10 68
630 95119 990 840 956 898 515 685 855 4xM10 74
Accessories

800 95216 1210 1050 1174 1120 - - - 4xM12 92


Accessories | 425

SSV, SSV/F, A1


A2
M

SSV-EX
Socket silencer for
DVV/120, DVV/F,
DVV-EX
The socket silencers are suitable for mount-

H
ing on flat roofs. Casing manufactured from

480
aluzinc steel, insulation/baffles of mineral
wool with a textile lining. For versions .../F
(smoke extract) and EX the baffles are se-
cured with an additional metallic guard. The
surface of the baffles is abrasion resistant. E

30
M8
Silencers come complete with nuts at the G
bottom to fix further inlet-side accessories. B
Supplied with sealing between socket and
fan. SSV-EX with extra bolt for earthing.
SSV / Art. Nr. Art. no. £A1 £A2 £B M H £E £G kg
SSV/F SSV-EX
Attention! Automatic shutters VKVE/F, VKV/F
400 3728 / 4424 - 535 460 720 12 750 444 496 35/39
cannot be installed into the silencer. Auto-
450/560 3729 / 4425 95297 685 600 870 12 800 594 646 48/55
matic shutter for DVV-Ex cannot be installed
into SSV-EX. 630/800 3731 / 4427 95298 975 880 1160 16 900 879 936 95/107
1000 4423 / 4429 95299 1120 1040 1400 16 950 1023 1079 123/136

Pressure drop
Pressure drop dp [Pa]

Noise reduction
Noise reduction [dB]

Accessories

Frequency [Hz]
426 | Accessories

FSL FSL
450
A
800
B
550
HF*
210
E
305
kg**
26
FSL Art. no. Suitable for DVV/F400,
F600
Flaps for 560 800 550 235 305 27 450 33084 DVV 450
snow load, 630 910 550 285 400 35
560 33085 DVV 560
DVV roof unit 630-XS/XL 985 622 270 413 41
630 33086 DVV 630, DVV 630 K
630-XS/XL 95348 DVV 630-XS, XL
Smoke and heat extract unit DVV with FSL 800 K 4-pole 1050 700 285 428 47
800 K 4-pole 33087 DVV 800D4-K, 4-8-K, 4-6-K
flaps as accessories has the same rating as the 800 1050 700 285 428 50
basic unit, but snow load rating SL 1000. DVV 800 33088 DVV 800D6, 6-12, 8, 6-K, M,
800 M, P 1280 927 295 446 59 P, 6-8-K, M,P, 6-12-K
with FSL flaps is suitable for installation on non 800-XS/XL- 1189 812 331 533 61 800 M, P 33089 DVV 800D4-M,P, 4-8-M,P,
heated buildings with snow load requirement H1105 4-6-M,P
SL 1000. 800-XS/XL- 95349 DVV 800D4-XS, 6-XS, 6-8-XS,
800XS/XL- 1277 812 351 544 66
• SL 1000 according to EN 12101-3 H1105 6-XL
H1280
• 400°C/120 min. (F400) or 600°C/120 min. 800-XS/XL- 95350 DVV 800D4-6-XS, 4-XL,
1000 1420 1090 273 466 66
(F600), depends on basic DVV fan H1280 4-6-XL
• Up to 120°C continuous operation 1000 M, P 4-pole 1420 1090 273 466 68 1000 33090 DVV 1000D6, 6-8, 6-12, 8,
• Flaps made from hot-dip galvanized steel 1000XL/XP 1390 913 327 535 69 8-12, 6-M,P, 6-8-M,P
• Vertical exhaust 1000 M, P 4-pole 33092 DVV 1000D4-M,P, 4-8-M,P,
4-6-M,P
• Tested according to EN 12101-3 at TU Mu- * HF corresponds additional height of DVV,
nich for temperatures up to 600°C/120 min. when FSL mounted 1000XL/XP 95353 DVV 1000D6-XL, 6-8-XL,
8-XL, 4-XM, 4-6-XM, 4-8-XM,
• Recommended to order factory mounted on ** Additional weight for DVV 4-XP, 4-6-XP, 4-8-XP
the fan (saving place for transportation, sav-
ing time and costs for mounting on site). 160
95353
• They can also be mounted after installation FSL
Pressure drop (Pa)

33090
of the fan 140 33092

B 120

100
HF

80 33089
95349
E

33087 95350
60 33088
33086
A
closed 33084 33085 95348
40

20
Air volume (x1000 m3/h)
0
opened 0 10 20 30 40 50

HSDV HSDV Art. no. Suitable for DVV/F400,


F600, DVV/120, DVV-Ex
Discharge silencer 400 95077 DVV 400
for DVV roof unit 450/560 95078 DVV 450, 560, DVV-Ex 560
Vertical outlet silencer 630 95080 DVV 630-K, DVV 630,
DVV-Ex 630-K, DVV-Ex 630
manufactured from
800 95081 DVV 800-K, DVV 800, DVV
seawater resistant aluminium. Suitable for
800 M, P 6 pole, DVV-Ex
DVV/120, DVV/F400 and DVV/F600. Certi- 800-K, DVV-Ex 800
fied together with DVV/F according to EN 800 M,P 95082 DVV 800D4-M, P, 4-8-M, P,
12101-3. With some additional details suit- 4-6-M, P
able also for DVV-Ex (only factory mounted 1000 95083 DVV 1000, DVV 1000D6-M,
possible). 50 to 80 mm mineral wool insula- P, 6-8-M, P, DVV-Ex 1000
tion with perforated steel cover. 1000 M,P 95123 DVV 1000D4-M, P, 4-8-M,
HSDV can be retrofitted (exception: DVV- P, 4-6-M, P
Ex), but connection box rsp. service switch
should be dismounted to fit the casing to Note 1: m (kg) - weight of HSDV alone,
cooling duct. Noise attenuating 7 to 8 dBA. without fan.
Note 2: m1 (kg) - additional weight of fan,
HSDV for the fans DVV-XS/XL on request when HSDV mounted instead of
Accessories

available. original casing.


HSDV A E F G m m1
kg kg Note 3: E* for 1000-P 4 pole only (2 cooling
400 573 200 732 730 18 14 ducts).
450/560 723 220 908 830 25 19 Note 4: E** for DVV 400 - 630 (cooling duct
630 1023 175 1200 1050 45 30 45° to axis).
800 1023 230 1432 1163 66 44
Note 5: FSL snow load flaps for HSDV resp.
800 M,P 1023 200 1516 1353 80 54 DVVI on request.
4-pole
Note 6: DVVI-Ex without cooling ducts,
1000 1183 245 1660 1480 96 68
connection box on casing.
1000 M,P 1183 314 1660 1480 96 40
4-pole
Accessories | 427

VKS, VKM, VKS


190/225
Art. Nr. øda
9539 235
øe
217
ødi
183
h4
115
zxd
6x8x12*
VKS-EX, 310/311 9543 306 286 255 156 6xø10

VKSV-EX 355-500
560/630
9544
9545
464
639
438
605
406
573
220
255
6xø10
8xø10
Automatic and 710 9546 708 674 638,5 250 8xø10
motor driven 800/900 9547 910 872 801 340 8xø10
shutter
The shutters VKS and VKM are manufactured VKM Art. Nr. øda øe ødi h4 l1 zxd
from galvanized steel, shutter blades from 310/311 9555 306 286 255 156 210 6xø10
seawater resistant aluminium. 355-500 9556 464 438 406 220 290 6xø10
VKM is equipped with a servo motor 560/630 9557 639 605 573 255 375 8xø10
(230V/50Hz/25W), which can be operated
710 9558 708 674 638.5 250 400 8xø10
manually as well as through the automatic
800/900 9559 910 872 801 340 500 8xø10
controllers of the air conditioning unit. While
the motor is energized the shutter stays
VKS-EX Art. Nr. øda øe ødi h4 zxd
open. When separated from the supply the
shutter will close automatically. Temperature 310/311 8483 306 285 256 156 6xø7
approx 70°C. Suitable for DVS/DHS, DVSI, 355-500 8484 464 438 402 220 6xø9
DVN. 560/630 4813 639 605 569 255 8xø9
The automatic shutter VKS-EX/VKSV-EX
consists of flanges manufactured from gal- VKSV-EX Art. Nr. øda øe ødi h4 zxd
vanized steel epoxy painted RAL 9005, and 630 4803 584 541 504,5 255 12xø12
of shutter blades manufactured from painted 800 4804 708 674 638 255 16xø12
galvanized steel RAL 9005. 1000 4805 814 751 711,5 350 16xø12

Pressure drop VKS/VKM Pressure drop VKS-EX

VKS-EX 310/311
VKS-EX 355/500
VKS-EX 560/630

VKS 190/225
VKS/VKM 310/311
VKS/VKM 355/400
VKS/VKM 560/630
VKS/VKM 710
VKS/VKM 800/900

m³/h m³/h

Pressure drop VKSV-EX

VKSV-EX 630
VKSV-EX 800/1000
Accessories

m³/h
428 | Accessories

VKV/F, VKV/F, VKG/F


Ød2
VKVE/F
ød2
VKVE/F, Øe
Ød
øe
ød n x ød3
VKG/F
n x Ød3

Automatic shutter
VKV/F and VKVE/F for

H
roof fans DVV F400,
F600 and 120° (not
DVV-Ex), VKG/F for roof
fans DVG and DVV-XS/XL. VKG/F sizes 630 VKV/F, Art. no. ød øe ød2 H nxød3 kg
and 800 have two pitch diameters (DIN for VKVE/F
DVG and Eurovent for DVV-XS/XL) The cas- 400 3710 / 31112 322 356 386 160 8x9,5 4.3
ing and blades are manufactured from aluz- 450 3711 / 31113 360 395 425 175 8x9,5 5
inc steel. 560 3712 / 31114 404 438 468 180 12x9,5 5.7
630 3713 / 31115 507 541 571 250 12x9,5 9
800 3714 / 31116 636 674 712 290 16x11,5 15
1000 3715 / 31117 713 751 789 350 16x11,5 20

VKG/F Art. no. ød øe ød2 H nxød3 kg


315-450 309952 404 438 468 180 6x9 6
500-560 309953 569 605 643 240 8x9 11
630* 309954 636 674/690 712 290 8x9 / 12x12 15
800* 95133 797 872/860 903 330 8X10 /16x12 22
* 2 pitch diameters, same flange

Pressure drop VKV/F - VKVE/F Pressure drop VKG/F

VKV/F - VKVE/F
VKG/F
100

100
Pressure drop (Pa)

Pressure drop (Pa)

560 630
450 315 - 450 500 - 560 630 800
400
400 800 1000

10
Air volume (m3/h) 10
10000 1000 10000 Air volume (m3/h)

ASSV, ASSV
400
Art. no.
3716
ød
322
øe
356
ød2
382
n x ød3 kg
8x9.5 2.9

ASSV/F 450
560
3717
3718
361
404
395
438
421
464
8x9.5
12x9.5
3.1
3.5
Flexible connection 630 3719 507 541 584 12x9.5 4.5
for DVV roof unit 800 3720 638 674 712 16x11.5 10.2
The flexible connections prevent transmis- 1000 3721 715 751 802 16x11.5 11
sion of vibration to the duct system. With
flanges in galvanized steel and neoprene ASSV/F Art. no. ød øe ød2 n x ød3 kg
fabric, in the high temperature version 400 3722 322 356 382 8x9.5 2.9
ASSV/F with high temperature resistant fab- 450 3723 361 395 421 8x9.5 3.1
Accessories

ric. The smoke extract version was tested


560 3724 404 438 464 12x9.5 3.5
together with the DVV range in accordance
630 3725 507 541 584 12x9.5 4.5
with EN 12101-3.
800 3726 638 674 712 16x11.5 10.2
1000 3727 715 751 802 16x11.5 11
Accessories | 429

ASSG/F
Flexible connection
for DVG and DVV-
XS/XL fans
The flexible connections
prevent transmission of eventual vibrations
to the duct system. Galvanized steel flanges
with high temperature resistant fabric. Suit-
able for the DVG and DVV-XS/XL fans in
accordance with EN 12101-3 (F400 - 400°C, ASSG/F Art. no. ød øe ød2 nxd3 kg
2 hours). 315-450 309955 402 438 475 6X9 4
ASSV/F sizes 630 and 800 have two pitch
500/560 309956 569 605 652 8X9 7.5
diameters (DIN for DVG and Eurovent for
pitch ø1 674 8X9
DVV-XS/XL). 630* 309957 638 723 10.2
pitch ø2 (Eurovent) 690 12x12
pitch ø1 872 8X10/
800/1000* 95214 797 910 12
pitch ø2 (Eurovent) 860 16x12
* 2 pitch diameter, same part

VKVM VKVM Art. no. ød ød1 ød2 n x ød3 A d2


d1
400 31250 322 356 386 8x9.5 100 n x d3
Motorized shutter
450 31251 360 395 425 8x9.5 120

B
VKVM motor driven 560 31252 404 438 468 12x9.5 140
shutter. Suitable for roof

C
630 31253 507 541 571 12x9.5 105

H
fans DVV/120.
800 31254 636 674 712 16x11.5 170
Temperature up to 70°C.
1000 31255 713 751 789 16x11.5 210
The blades are manufactured from galva-

A
nized steel. With direct coupled 230V/50Hz
VKVM Art. no. B C D H kg D
ON-OFF spring return actuator. The blade d
400 31250 0 190 260 250 5.8
opens when applying supply voltage. If the
power supply is interrupted, the blade 450 31251 0 190 280 250 6.5
closes. Manual operation is possible. 560 31252 10 190 305 250 7.2
630 31253 0 250 365 395 10.3
Can not be used for DVV/F fans. 800 31254 65 250 445 395 22
1000 31255 105 250 485 395 25

ESDV ESDV Art. no. ød øe ød2 H nxød3 kg


400 31118 322 356 369 160 8x9.5 4.3
Inlet cone DVV 450 31119 360 395 407 175 8x9.5 5
For use together with the 560 31120 404 438 451 180 12x9.5 5.7
roof fan DVV. For improving 630 31121 507 541 586 250 12x9.5 9
free inlet air flow. The inlet cone is manu-
800 31122 636 674 716 290 16x11.5 15
factured from galvanized steel. Additional to
1000 31123 713 751 811 350 16x11.5 19
VKV/F or to duct inlet.

ASFV ASFV Art. no. ød øe ød2 nxd3 kg for DVV for DVG
400 3699 - 322 356 390 8x9.5 0.8 400 -
Inlet flange
450 3698 - 361 395 428 8x9.5 0.9 450 -
Counter flange for connec-
V560/ 3700 - 402 438 475 12x9.5 1.3 560 315-450
tion to a duct system or to the accessories.
Accessories

G315-450
Manufactured from galvanized steel.
630 3701 - 505 541 584 12x9.5 1.8 630 -
Suitable for DVV, DVG, DVV-XS/XL fans and
accessories. G500-560 95121 - 569 605 652 16x12 2.1 - 500-560
V800/ pitch ø 1 674 16x12 800 630
3702 638 723 2.4
G630* pitch ø 2 (Eurovent) 690 12x12 630-XS/XL
1000 3703 - 712 751 802 16x12 2.8 1000 -
pitch ø 1 872 8x10 - 800
G800* 95219 pitch ø 2 (Eurovent) 797 860 910 16x12 3.5 800-XS/XL,
1000-XL
* 2 pitch diameters, same flange
430 | Accessories

RSA (F) L
F
I

Silencer
Silencer RSA(F) for
use together with
axial fans of AXC-
Range. For effective sound reduction the si-

E
lencer should be mounted directly before or
after the fan. The silencers are supplied with
a flange according to Eurovent 1/2.

Noise suppression dB frequency band Hz


RSA (F) øI øE øF AxB L Art. no. L Art. no. L Art. no.
ØI/L 125 250 500 1 k 2 k 4 k 8 k
315 315 455 355 8xM8 315 311346 472.5 311347 630 311348
315/315 1 3 8 14 9 8 7
355 355 495 395 8xM8 355 311349 532 311350 710 311351
315/472 2 5 12 19 13 11 8
400 400 540 450 8xM10 400 311352 600 311353 800 311354
315/630 6 6 16 26 17 13 9
450 450 610 500 8xM10 450 311355 675 311356 900 311357
355/355 0 3 9 14 10 8 6
500 500 660 560 12xM10 500 311358 750 311359 1000 311360
355/532 0 5 12 21 13 11 9
560 560 720 620 12xM10 560 311361 840 311362 1120 311363
355/710 2 6 15 25 16 12 10
630 630 790 690 12xM10 630 311364 945 311365 1260 311368
400/400 0 4 10 13 8 8 5
710 710 870 770 16xM10 710 311369 1065 311370 1420 311371
400/600 1 5 14 19 12 10 8
800 800 1000 860 16xM10 800 311372 1200 311373 1600 311374
400/800 2 7 18 24 15 12 9
900 900 1100 970 16xM12 900 311375 1350 311376 1800 311377
450/450 1 4 12 12 9 6 6
1000 1000 1200 1070 16xM12 1000 311378 1500 311379 2000 311380
450/675 1 6 17 17 13 9 8
1120 1120 1320 1190 20xM12 1120 311381 1680 311382 2240 311383
450/900 1 7 21 21 15 10 8
1250 1250 1450 1320 20xM12 1250 311384 1875 311385 2500 311386
500/500 0 4 13 11 9 6 5
500/750 1 6 18 17 12 9 7
500/1000 2 8 23 21 14 11 8
560/560 0 4 14 11 8 5 4 LRK(F)
560/840 2 7 20 15 11 8 5
Automatic shutter For use in horizontal and vertical installation.
560/1120 1 9 24 19 14 10 7
The casing and blades
630/630 1 5 14 10 9 5 5 are manufactured from NOTE: Not usable for downwards directed
630/945 2 7 20 14 12 8 6 galvanized steel. For use air direction and also not usable on inlet side
with the AXC axial fan of the fan!
630/1260 2 9 25 17 14 10 7
range with temperatues up to 400°C/2h.
LRK (F) Pressure drop
300
280
[Pa]

Noise suppression dB frequency band Hz Ø LK


L U 260
240
ØI/L 125 250 500 1 k 2 k 4 k 8 k z x Ød 220
200
710/710 1 5 12 9 7 5 5 180
160
710/1065 2 7 18 11 9 6 7 140
Ø Da
Ø Di

120
710/1420 4 9 24 14 11 8 8 100
80
800/800 3 7 9 8 6 5 4 60
40
800/1200 5 10 13 12 9 7 7 20
0
800/1600 6 13 22 14 10 9 7 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44

900/900 3 7 13 8 6 5 4 [m/s]

900/1350 5 11 16 11 7 7 5
LRK(F) Art. no. øda ødi øLK zxød L U W°
900/1800 6 14 23 13 9 7 6
315 8316 398 320.5 355 8xø10 250 - 0°
1000/1000 3 8 12 8 4 4 4
355 8317 438 359.5 395 8xø10 250 - 5°
1000/1500 5 12 17 10 6 6 5 400 8318 484 401.5 450 8xø12 250 - 5°
Accessories

1000/2000 6 16 23 12 7 7 6 450 8319 534 450.5 500 8xø12 250 13,6 5°


1120/1120 3 8 13 7 5 4 3 500 8320 584 504.5 560 12xø12 250 35 15°
1120/1680 5 12 18 8 6 5 4 560 8321 664 565.5 620 12xø12 250 64.8 15°
1120/2240 6 15 23 10 7 6 6 630 8322 734 634.5 690 12xø12 250 101.2 15°
1250/1250 3 9 13 7 4 4 3 710 8323 812 711 770 16xø12 350 39.3 15°
1250/1875 6 12 17 8 5 5 4 800 8324 904 797.5 860 16xø12 350 83 15°

1250/2500 8 17 22 10 6 6 5 900 8325 1004 894 970 16xø15 350 134 15°
1000 8326 1105 1003.5 1070 16xø15 350 180 15°
1120 30459 1242 1122 1190 20xø15 350 245 15°
1250 8327 1350 1250.5 1320 20xø15 400 249 15°
Accessories | 431

SG AW-D B
A

Protection guard
For axial fans, model
range AW. Outlet mount-
ing. Steel with black pow-

D1
D2

D3
der coating, RAL 9005.

E
D4

SG AW-D Art. no. A B øE øD1 øD2 øD3 øD4


350 30600 154 95 422 380 387 444 7
400 30601 145 64 500 431 424 522 7
450 30602 187 131 560 487 455 582 7
500 30603 184 83 615 539 522 637 7
560 30604 223 120 658 597 569 680 7
630 30605 231 127 720 682 677 742 7
710 30606 295 152 835 743 702 857 9,5

SG AR/AXC, SG AR/AXC
200
Art. no.
313298
øB
225

90
nxød1
4xø7
kg
0.2
SG AR/AXC

SG AW 250 313299 280 90 4xø10 0.3


315 310685 355 45 8xø10 0.5
Protection guard
355 310686 395 45 8xø10 0.8
For axial fans of the Range AXC and AR sileo
400 310687 450 45 8xø12 1.5
with flange dimensions according Eurovent
450 310688 500 45 8xø12 2.0
1/2. Steel with black powder coating, RAL
9005. 500 310689 560 30 8xø12 1.3
SG-AW: Protection guard for inlet side for 560 310690 620 30 8xø12 1.4
axial fans of Range AW. 630 310691 690 30 8xø12 1.7
710 310692 770 22.5 8xø12 2.5
n x d1
800 310693 860 22.5 8xø12 3.0 w
B
900 310694 970 22.5 8xø15 2.5
1000 310695 1070 22.5 8xø15 5.0 SG AW
1120 310696 1190 45 8xø15 3.0
1250 310697 1320 45 8xø15 6.0

SG AW Art. no. A øD1 øD2 øD3 ØE


710 3395 4x90° 782 856 9 835
800 3397 4x90° 901 979 9 960
900 301300 4x90° 1030 1134 9 1115
1000 3398 4x90° 1110 1161 9 1140

MPR
DI
MPR * Art. no. øDA øDI øTK ZxøD K M N
315 309800 395 315 355 8x10 495 575 150
N

Mounting ring AXC 355 309801 435 355 395 8x10 535 615 150 DA

MPR mounting ring for 400 309802 480 400 450 8x12 580 660 150 Zx
TK
D

vertical mounting of the 450 309803 530 450 500 8x12 630 710 150
4x 11
Accessories

Axial fans series AXC. 500 309804 590 500 560 12x12 696 776 150
Manufactured from hot 560 309805 650 560 620 12x12 758 838 150
dip galvanized steel.
630 309806 720 630 690 12x12 828 908 150
710 309807 800 710 770 16x12 908 988 150
800 309808 890 800 860 16x12 998 1078 150
900 309809 1005 900 970 16x15 1108 1188 150
K

1000 309810 1105 1000 1070 16x15 1208 1288 150


M

* Nominal fan diameter


432 | Accessories

MP MP
Nominal fan
Art. no. L T bM ød

Mounting brackets diameter


1120 306759 695 157 120 17
Mounting brackets for vertical
1120 306760 991 157 120 17
mounting of medium pressure

L
axial fans. Manufactured from hot 1250 306758 840 155 130 17
dip galvanized steel. 1250 306761 1038 156.5 150 17
Four pieces per fan needed, not possible to Depends on casing length of Axial fan AXC
retrofit, has to be ordered with the fan.
ød
bM T

MFA-AR/ MFA 315-450 MFA 500-1250

AXC
Mounting feet
TK
W s s

TK
hf

hf
The mounting feet MFA AXC is manufactured D1 W

D2 D2
from hot dip galvanized steel, with holes for D1
mounting at flanges according Eurovent 1/2.

F
C B C B
A A
D2 D2

E
E
C C

MFA AXC Art. no. A B C E F D2 s TK D1 W hf


315 311283 315 60 265 30 25 14 2.5 355 10 45 235
355 311284 355 60 305 30 25 14 2.5 395 10 45 250
400 311285 400 60 350 30 25 16 2.5 450 12 45 280
450 311286 450 60 400 30 30 16 2.5 500 12 45 315
MFA AXC Art. no. A B C E F D2 s TK D1 W hf
500 311287 500 70 440 35 45 16 3,0 560 12 30 335
560 311288 560 70 500 35 35 16 3,0 620 12 30 375
630 311289 630 70 570 35 35 16 3,0 690 12 30 425
710 311290 710 70 650 35 35 18 5,0 770 12 22,5 450
800 311291 800 80 730 40 40 18 5,0 860 12 22,5 530
900 311292 900 80 830 40 40 18 5,0 970 15 22,5 560
1000 311293 1000 80 930 40 40 18 5,0 1070 15 22,5 670
1120 311294 1120 80 1030 40 50 18 5,0 1190 15 18 710
1250 311295 1250 100 1180 50 50 18 5,0 1320 15 18 800

MFA-AXCBF
Mounting feet MFA 250-500 MFA 630-800
For use with the AXCBF F

range. The mounting feet MFA-AXCBF are


TK

manufactured from galvanized steel. E


s
TK
hf

I W
B

D2
H

D1
D C
F

A
C B
D A
D2
Accessories

MFA-AXCBF Art. no. A B C D E F H I J TK


250 313300 250 40 60 210 35° 3 25 4x12 2x10 280
315 308725 315 50 60 265 45° 3 25 4x14 2x10 355
400 308726 400 65 60 350 45° 3 30 4x16 2x10 450
500 308727 500 125 70 440 60° 3 42 4x16 3x12 560
MFA-AXCBF Art. no. A B C E F D2 s TK D1 W hf
630 311289 630 70 570 35 35 16 3.0 690 12 30 425
800 311291 800 80 730 40 40 18 5.0 860 12 22,5 530
Accessories | 433

DF-AJ SD-AXC G
A
E
Guide vane Jet Vibration damper F

Guide vanes manufac- Rubber-metal-bearing for


tured from galvanized active and passive vibration- and impact
steel, to direct the air sound isolation. Suitable for temperatures

B
flow are available as from -40°C up to 70°C.
assessories for AJR-TR. øD
L SW
øC

SD Art. no. A B øC øD E F G SW
c

315-450 8340 45 35 30 6 15 M6 60 11
Di 500-630 8341 70 50 45 9 27 M10 90 17
A
B

710-1000 8342 105 80 70 13 45 M16 140 24

FSD-AXC Numeric data of the spring (FSD)


Description Nominal range Spring rate
Spring damper AXC/ per FSD [N] [N / mm]
DF-AJ Art. no. A B C øDi L set
FSD1 120 - 225 7,93
315 309655 90 115 85 420 207 Spring damper for active
FSD2 195 - 370 12,90
355 309656 90 115 85 460 207 and passive vibration- and impact sound
400 309657 130 130 85 505 207 isolation. Steel spring vibration isolators con- FSD3 300 - 620 20,16
sist of a cylindrical screw spring designed FSD4 475 - 1100 31,64
according to DIN EN10270-1:2001 with two
DF AJ8 end plates with M10 internal thread. FSD5 720 - 1600 48,07

Spring damper set consists of 4 pcs spring FSD6 1130 - 2455 75,56
Guide vane Jet dampers including base plate. FSD7 1815 - 3680 121,03
Guide vanes galva- For the selection of FSD the weight-force
nized steel, to direct FSD8 2800 - 4910 187,10
(in N) at the point of support and the oscilla-
the air flow. Available tion frequency (1/min) is needed. FSD9 3750 - 6380 234,30
as accessories for AJ8.
D 70
D 70
M10
M10
Spring damper

High without load


95
11

95
11
94
94

Base plate

120 12
12

150

DF-AJ8 Art. no. A1 A2 B C


315 300886 30° 30° 5.5 4
355
400
300887
303989
30°

30°
60°
5.5
5.5
4
4
ZSD-AXC
Tension load spring
DF-AJ8 Art. no. øD øDA H L damper AXC/set The cylindrical screw spring is designed ac-
315 300886 400 420 276 107
Spring damper for active cording to DIN EN10270-1:2001.
355 300887 420 450 305 138 Spring damper set consists of 4 pcs spring
and passive tensile vibration
400 303989 464 500 313 138 loads and sound insula- dampers.
tion. Unit consists of a rectangular housing, For the selection the weight-force (in N)
a spring element and two connection nuts at the point of support and the oscillation
Safety-Anchor for with M10 internal thread for threaded rods. frequency (1/min) is needed.

Jet installation
Accessories

100 x 73
Numeric data of the spring (ZSD)
M10
Description Nominal range per ZSD [N] Spring rate [N/mm]
ZSD1 120 - 225 7.93
ZSD2 195 - 370 12.90
Image source: Hilti Deutschland AG
ZSD3 300 - 620 20.16
120

190

Approved under ETA-02/0027. ZSD4 475 - 1100 31.64

AJR-TR AJ8 IV ZSD5 720 - 1600 48.07


M10
M8x40/15 M10x40/20 M12x60/20 ZSD6 1130 - 2455 75.56

4 pieces per Jet fan. ZSD7 1815 - 3680 121.03


434 | Accessories

IS / US
Inlet EX 140 Art. no. EX 180 Art. no.
ø125 IS 1412 4022 – –
ø160 IS 1416 4025 IS 1816 4023
ø200 – – IS 1820 4027

Inlet/outlet sleeve
Outlet EX 140 Art. no. EX 180 Art. no.
Inlet/outlet sleeve for EX fans including plate
ø125 US 1412 5125 – –
and screws. Manufactured from galvanized
steel. Makes it possible to connect the fans ø160 – – US 1816 5126
to spiral duct.

ISE / USE

For DKEX
Size Inlet Art. no. Outlet Art. no.

Flexible connections 225 ISE 225/250 5108 USE 225 1596


250 ISE 225/250 5108 USE 250 1597
Flexible connections for the DKEX centrifu-
gal radial fans. ISE supply connection is fixed 280 ISE 280/315 5109 USE 280 1598
with a strap to the spiral ducting. 315 ISE 280/315 5109 USE 315 1599
ISE: flex. length 100-158 mm. 355 ISE 355/400 5110 USE 355 1600
USE: flex. length 65-120 mm. 400 ISE 355/400 5110 USE 400 1601

ASS-EX,
ASSV-EX For DVEX øe
ASS-EX Art. no. øda øe ødi h3 zxd
310/311 4830 306 285 256 130 6xø7
h3

355-500 4831 464 438 402 130 6xø9


560/630 30597 639 605 569 130 8xø9

Flexible connection For DVV-EX


Manufactured from galvanized steel, with ASSV-EX Art. no. øda øe ø di h3 zxd
neoprene coated antistatic fabric. 630 4806 584 541 504 155 12xø12
For temperature up to 70°C. 800 4807 708 674 638 155 16xø12
Suitable for DVEX, DVV-EX. 1000 4808 814 751 711 155 16xø12

DS-EX
DS-EX Art. no. A B
50-25 4116 500 250
B+40
B+20
B
Accessories

50-30 4117 500 300


60-30 4118 600 300
60-35 4119 600 350 A

70-40 4120 700 400 A+20

Rectangular flexible connections A+40

Flexible connections for the KTEX. Fitted with


flanges to match the fan. Flexible lengths
120
60

from 100 to 158 mm. Flange width 20 mm.


Accessories | 435

FKX BS Cable
gland set
Bracket EX Protection guard EX
Mounting bracket for EX 140 and 180, manu- Manufactured from galvanized sheet steel,
factured from galvanized steel. for EX 140 and 180.
A2F, cable glands Ex d and Ex e
Art. no. 1556
BS 140 = Art. no. 4029 Manufactured from brass. Suitable for use
BS 180 = Art. no. 4032 with normal unarmoured cables. Including
gasket and counter nut.

Size Art. no.


A2F/20/M20 EXD 303019
A2F/20S/M20 EX 303029
A2F/25/M25 EXD 302055
A2F/32/M32 EXD 303066
A2F/40/M40 EXD 303067
A2F/50/M50 EXD 302067
A2F/50S/M50 EX 302077

EV-EX/ W1
°
S
L

AXC
W2°

zxd2

zxd1
ØDa (außen)

ØDi (innen)
ØTk1
ØTk2

Flexible connection
Flexible connections for the AXC-EX range.
The flexible connections consist of 2 counter
flanges manufactured from galvanized steel
with flexible PVC-EX coated fabric in be-
tween. When flexible connectors are fitted,
those have to be earthed. EV/EX Art. no. øDa øDi øTK1 zxd1 W1° øTK2 zxd2 W2° L s
315 308411 390 322 355 8xø10 45 - - - 154 1,5
355 308412 428 361 395 8xø10 45 - - - 154 1,5
400 308413 475 402 438 12xø9,5 30 450 8xø12 22,5 154 2,0
450 308414 524 455 487 12xø9,5 30 500 8xø12 22,5 154 2,0
500 308415 577 505 541 12xø9,5 30 560 12xø12 15 154 2,0
560 308416 652 569 605 16xø12 22,5 620 12xø12 30 154 2,0
630 308417 723 638 674 16xø12 22,5 690 12xø12 30 154 2,0
710 308418 802 712 751 16xø12 22,5 770 16xø12 11,25 154 2,0
800 308419 890 797 837 24xø12 15 860 16xø12 11,25 154 2,0
900 308420 1000 894 934 24xø12 15 970 16xø14 11,25 154 2,5
Accessories
436 | Accessories

EV-AR/AXC W2
W1
ØD
1 s
nx
Flexible connec-
D2
tion nxØ

K2
Flexible connections

ØDa
ØT
K1
for the AR/AXC range ØT
of axial fans. The flex- ØDi

ible connections consist of 2 counter flanges


manufactured from galvanized steel with
flexible neoprene coated fabric in between.

EV-AR/AXC Art. no. øDa øDi L nxøD1 øTK1 W1 nxøTK2 øTK2 W2 s


200 308869 250 201 153 4xø7 225 45 - - - 1.5
250 311174 328 251 153 4xø10 280 45 8xø10 302 45 1.5
315 8352 390 322 153 8xø10 355 22.5 - - - 1.5
355 8353 435 361 153 8xø10 395 22.5 - - - 1.5
400 8354 480 402 154 8xø12 450 22.5 12xø10 438 30 2.0
450 8355 534 455 154 8xø12 500 22.5 12xø10 487 30 2.0
500 8356 585 505 154 12xø12 560 15 12xø10 541 30 2.0
560 8357 652 569 154 12xø12 620 15 16xø12 605 22.5 2.0
630 8358 723 638 154 12xø12 690 15 16xø12 674 22.5 2.0
710 8359 802 712 154 16xø12 770 11.25 16xø12 751 22.5 2.0
800 8360 890 797 154 16xø12 860 11.25 24xø12 837 15 2.0
900 8361 1005 904 162 16xø15 970 11.25 - - - 2.5
1000 8362 1105 1003 165 16xø15 1070 11.25 24xø12 1043 15 2.5
1120 300849 1225 1122 165 20xø15 1190 9 24xø12 1174 15 2.5
1250 8363 1370 1250 165 20xø15 1320 9 24xø12 1311 15 2.5

EVH
Flexible connection EVH 250, 400-1250
(max. 400°C/2h) °
L
W1 S

The flexible connections


W2°

zxd2
avoid vibration transmission of vibrations to the
zxd1
duct system. With galvanized steel flanges and
high temperature resistant fabric.
ØDa (außen)

ØDi (innen)
ØTk1
ØTk2

EVH 315-355

5
9,
Ø
x
8
EVH Art. no. øDa øDi øTK1 zxd1 W1° TK2 zxd2 W2° L s
250 311163 328 251 280 8xø10 45 302 4xø10 90 154 1.5
W
400 8366 475 402 438 12xø9.5 30 450 8xø12 22.5 154 2
Accessories

K
øL
Ød 450 8367 524 455 487 12xø9.5 30 500 8xø12 22.5 154 2
ØDa

500 8368 577 505 541 12xø9.5 30 560 12xø12 15 154 2


560 8369 652 569 605 16xø12 22.5 620 12xø12 15 154 2
630 8370 723 638 674 16xø12 22.5 690 12xø12 15 154 2
30 710 8371 802 712 751 16xø12 22.5 770 16xø12 11.25 154 2
154
800 8372 890 797 837 24xø12 15 860 16xø12 11.25 154 2
900 8373 1005 903 - - - 970 16xø15 11.25 154 2.5
EVH Art. no. øDa ød øLK W° 1000 8374 1105 1003 1043 24xø12 15 1070 16xø15 11.25 154 2.5
315 8364 390 322 356 45° 1120 300850 1225 1122 1174 24xø12 15 1190 20xø15 9 154 2.5
355 8365 428 361 395 45° 1250 8375 1370 1250 1311 24xø12 15 1320 20xø15 9 154 2.5
Accessories | 437

GFL-AR/ GFL-AR 200


s
GFL-AR/AXCBF 250 s

AXCBF
Counterflange

ØDa
ØDa

ØDi
ØDi
The counterflange is suitable for the AR sileo K1

W2
ØT K2
and AXCBF range of axial fans. Manufactured ØT ØT
K1
from galvanized steel. W1
n x Ø D1
n x ØD2
n x ØD1
L
L

GFL-AR Art. no. øDa øDi øTk1 nxøD1 L s


200 308868 250 201 225 4xø7 30 1.5

GFL-AR/AXCBF Art. no. øDa øDi øTk1 nxøD1 W1° øTk2 nxøD2 W2° L s
250 311162 328 251.5 302 8xø10 45 280 4x10 22.5 30 1.5

L
GFL-AR/
½ w2 s
w2° z x ød2
z x ød1

AXC w1°

Counterflange
For axial fans type AR and AXC. The counter- øTk2
øTk1
øDa

ø Di
flange GFL-AXC is manufactured from galva-
nized steel.

GFL-AR/AXC Art. no. ØDa ØDi ØTk1 zxØd1 w1 ØTk2 zxØd2 w2 L s


315 8376 390 322 355 8x10 45 355 8x10 45 30 1.5
355 8377 435 361 395 8x10 45 395 8x10 45 30 1.5
400 8378 480 402 438 12x10 30 450 8x12 45 30 2
450 8379 524 455 487 12x10 30 500 8x12 45 35 2
500 8380 585 505 541 12x10 30 560 12x12 30 35 2
560 8381 652 569 605 16x12 22.5 620 12x12 30 35 2
630 8382 723 638 674 16x12 22.5 690 12x12 30 35 2
710 8383 802 712 751 16x12 22.5 770 16x12 22.5 35 2
800 8384 890 797 837 24x12 15 860 16x12 22.5 35 2
900 8385 1005 903 - - - 970 16x15 55.5 55 2.5
1000 8386 1105 1003 1043 24x12 15 1070 16x15 22.5 55 2.5
1120 300848 1225 1122 1174 24x12 15 1190 20x15 18 55 2.5
1250 8387 1370 1250 1311 24x12 15 1320 20x15 18 55 2.5
Accessories
438 | Accessories

ESD-F
da4
d1 n x d3

Inlet cone
The inlet cone is manufactured
from galvanized steel. Suitable

H
for axial fans AXC range.
de
m x d4
d2
da3

ESD-F Art. no. ød1 øde ød2 øda3 øda4 H nxd3 nxd4
315 305256 355 320 395 438 398 160 8xø10 8xø10
355 305257 395 359 450 484 438 160 8xø10 8xø10
400 305258 450 401 500 534 484 160 8xø12 8xø12
450 305259 500 450 560 584 534 160 8xø12 12xø12
500 305260 560 504 620 664 584 160 12xø12 12xø12
560 305261 620 565 690 734 664 160 12xø12 12xø12
630 305262 690 634 770 812 734 160 12xø12 16xø12
710 305263 770 711 860 904 812 160 16xø12 16xø12
800 305264 860 797 970 1004 904 160 16xø12 16xø15
900 305265 970 894 1070 1105 1004 160 16xø15 16xø15
1000 305266 1070 1003 1190 1242 1105 160 16xø15 20xø15
1120 303848 1190 1122 1320 1370 1242 160 20xø15 20xø15
1250 305267 1320 1250 1470 1533 1370 160 20xø15 20xø15
Accessories
Accessories | 439

SD-PRF VKS-DVP ASS-DVP


Vibration damper Automatic shutter Flexible connec-
PRF (4 pcs.) for DVP tion for DVP
Rubber-metal-bearing The automatic shutter is Manufactured from
for active and passive vibration- and impact manufactured from PP. PVC.
sound isolation.

G Do Ø
A

s
E
F
l

Do Ø
B

L
øD
SW
øC 25

SD-PRF Art. no. A B øC øD


125 32567 45 35 30 6
160 32568 70 50 45 9 VKS-DVP Art. no. L I Do⌀ ASS-DVP Art.Nr. L S Do ⌀
200 311515 200 40 200 200 311523 150 3,0 200
SD-PRF E F G SW 250 311516 225 40 250 250 311524 150 3,0 250
125 20 M6 60 11 315 311517 260 50 315 315 311525 150 3,0 315
160 32 M10 90 17 400 311518 300 50 400 400 311526 200 3,0 400
(set of 4 pcs. each)

ASF-DVP VP
Inlet flange for Splinter protec-
DVP tion PRF
The flange is manufac- The splinter protec-
tured from PP. tion is manufac-
tured from PVC and
the bracket consists
I

of stainless steel.
5
I

VP Art. no. suitable for


s 125 305461 PRF 125
Do Ø
160 305462 PRF 160
180 305463 PRF 180
ASF-DVP Art. no. I S Do⌀ 200 305464 PRF 200
200 311519 40 3,0 200 250 305465 PRF 250
250 311520 40 3,5 250
315 311521 50 4,0 315
400 311522 50 4,5 400
Accessories
440 | Accessories

VKS-P VKA-P ASS-P


Automatic shutter Adjustable Flexible connec-
for PRF shutter for tions for PRF
The automatic shutter is PRF The flexible connection
manufactured from PP. The adjustable is manufactured from
shutter is manu- PVC.
factured from PP.

ØB ØB
ØB

A
A

ØB
ØB
ØB

VKS-P Art no. A øB VKA-P Art. no. A øB ASS-P Art. no. A øB


125 32374 205 125 125 32369 120 125 125 32364 155 125
160 32375 240 160 160 32370 120 160 160 32365 155 160
180 32381 260 180 180 32380 120 180 180 32379 155 180
200 32376 280 200 200 32371 120 200 200 32366 155 200
250 32378 330 250 250 32373 120 250

WSD PRF BDS BVK


Weather roof Back draught Wall vent kit
for motor shutter Wall lead-through BVK.
Additional weather Back draught shutter for Wall grid and flexible
protection for the bathroom fans. aluminium duct.
motor of PRF fans,
if the fan is outdoor mounted. Manufactured BDS Art. no. Length
from seawater resistant aluminium. The WSD 100 5927 55 mm
PRF is painted in RAL 5015. 120 5928 62 mm
150 5929 77 mm
A
C
B

2xM6 BVK Art. no. £E øD


100 5965 140 100
120 5966 160 125
WSD PRF Art. no. A B C D 150 5967 180 150
125 309456 228 173.5 210 60
Accessories

160 309457 283 201 270 60


180 309458 313 211 270 70
200 309459 348 218.5 320 70
250 309460 287 228.5 400 70
Accessories | 441

ZTV/ZTVB Technical data


Flow charac. Equal percentage
ZTV

Water valve, 2-way Media temp. °C 1...+110

42
Connection External thread
Max. stroke mm 5

ød
G
Max. leakage % 0
Pressure rating PN16 (1.6MPa)
• For water and cooling media (max. 30% Regulating ratio 50:1
glycol) Material body Brass I
• Media temperature 1...110°C Material cone Brass 60
• Pressure class PN16
Material spring Stainless steel
• Rangeability better than 50:1
• Differential pressure up to 350 kPa (ZTV)
• Differential pressure up to 250 kPa (ZTVB) ZTVB
ZTV Art. no. Connection G I M30x1.5

The control valves ZTV and ZTVB are 2-way 15-0,4 9829 DN15 1/2” 9
valves. The body and plug are manufactured 15-1,0 9823 DN15 1/2” 9
from brass, the spindle in stainless steel and 15-1,6 9824 DN15 1/2” 9
O-ring in EPDM. 20-2,0 9830 DN20 3/4” 12.5

H
ZTV valves have equal percentage flow char- 20-2,5 9825 DN20 3/4” 12.5
acteristics. ZTVB valves have linear flow char- 20-4,0 9826 DN20 3/4” 11.5
acteristics.
20-6,0 9827 DN20 3/4” 11.5

d

Valve actuators

L1
ZTVB Art. no. Connection d L L1 H
The valves are intended to be used together
25-8,0 4738 DN25 1” 90 44 65
with RVAZ4-24 or RVAZ4-24A actuators.
32-15 2588 DN32 1 1/4” 105 43 66
40-20 2589 DN40 1 1/2” 120 48 68
L

ZTR/ZTRB Technical data


Flow charac. Equal percentage
ZTR

Water valve, 3-way Media temp. °C 1...+110

42
Connection External thread
Max. stroke mm 5
Ød
G

Max. leakage % 0
Pressure rating PN16 (1.6MPa)

h
• For water and cooling media (max 30% Regulating ratio 50:1
l
glycol) Material body Brass
l

• Media temperature 1...110°C Material cone Brass Ød


• Pressure class PN16 Material spring Stainless steel G
• Rangeability better than 50:1 60
• Differential pressure up to 350 kPa (ZTR)
• Differential pressure upt to 250 kPA (ZTRB)
ZTR Art. no. Connection G I h
ZTRB M30x1.5
The control valves ZTR and ZTRB are 3-way 15-0,4 9670 DN15 1/2” 9 40
valves. The body is manufactured from brass 15-1,0 9672 DN15 1/2” 9 40
and spindle in stainless steel, the plug in brass 15-1,6 9673 DN15 1/2” 9 40
and O-ring in EPDM. 20-2,0 9674 DN20 3/4” 12.5 40
The valves have equal percentage flow 20-2,5 9677 DN20 3/4” 12.5 40
H

characteristics.
20-4,0 9678 DN20 3/4” 11.5 50
Accessories

20-6,0 9679 DN20 3/4” 11.5 50


Valve actuators
d

The valves are intended to be used together


with actuator RVAZ4-24A or RVAZ4-24. ZTRB Art. no. Connection d L L2 H
25-8,0 4735 DN25 1” 90 67 65
L2

32-15 2596 DN32 1 1/4” 105 75 66


40-20 2597 DN40 1 1/2” 120 85 68

L
Wiring
diagram

4
1

8
442

6a
blue

black/brown

yellow/green
| Wiring Diagram

N
L
TK TK Z2 Z1 U2 U1
Counter clockwise rotation

PE

9
5
2

6b

L
brown

C
blue brown

N
black blue

yellow/ black
green
yellow/green

U1 Z U2 PE TK TK
7
6
3

blue

brown

black

yellow/
green
Wiring Diagram | 443

10

230V3~ (D)

11a 11b

400V3~ (Y) 230V3~ (D)

T1 T2 L1 L2 L3 T1 T2 L1 L2 L3

K1 K2 W2 U1 U2 V1 V2 W1 K1 K2 W2 U1 U2 V1 V2 W1

12
diagram
Wiring
444 | Wiring Diagram

13a 13b

Electric motor with star - delta starting


Delta connection

Starting Y 400V U1 V1 W1 U2 V2 W2 PTC PTC

Operation D 400V U1 V1 W1 U1 V2 W2 PTC PTC


Star connection

13c
Electric motor with star - delta starting
ON U1 V1 W1 U2 V2 W2 PTC PTC NO NC PE
Starting
OFF

Lock the service switch in posi-


Y 400V L1 L2 L3 PTC PTC PE tion ON to prevent unintended
Max. 2.5V
switch OFF!
Lock is not in scope of fan.
ON U1 V1 W1 U2 V2 W2 PTC PTC NO NC PE

Operation
OFF

D 400V L1 L2 L3 PTC PTC PE


Max. 2.5V

13d
ON 1U 1V 1W 2U 2V 2W PTC PTC NO NC PE

Low speed
OFF
Two speed electric motor
(4-6, 6-8, 8-12)
Y 400V L1 L2 L3 PTC PTC PE Lock the service switch in
Max. 2.5V
position ON to prevent unin-
tended switch OFF!
ON 1U 1V 1W 2U 2V 2W PTC PTC NO NC PE
Lock is not in scope of fan.
High speed
OFF
diagram
Wiring

Y 400V L1 L2 L3 PTC PTC PE


Max. 2.5V
Wiring Diagram | 445

13e
Electric motor with star - delta starting

ON U1 V1 W1 U2 V2 W2 NO NC PE

Starting
OFF

Lock the service switch


Y 400V L1 L2 L3 PE in position ON to prevent
unintended switch OFF!
Lock is not in scope of fan.
ON U1 V1 W1 U2 V2 W2 NO NC PE

Operation
OFF

D 400V L1 L2 L3 PE

14a 14b

2U 2V 2W 2U 2V 2W
Low speed Y 400V
Low speed
1U 1V 1W 1U 1V 1W

PTC/TK
Dahlander
PTC/TK

2U 2V 2W 2U 2V 2W
High speed
YY 400V
High speed
1U 1V 1W 1U 1V 1W

14c

ON 1U 1V 1W 2U 2V 2W PTC PTC NO NC PE

Low speed
OFF Two speed electric motor in
Dahlander connection (4-8,
6-12)
Y 400V L1 L2 L3 PTC PTC PE
Max. 2.5V
Lock the service switch
in position ON to prevent
unintended switch OFF!
ON 1U 1V 1W 2U 2V 2W PTC PTC NO NC PE Lock is not in scope of fan.

High speed
OFF
diagram
Wiring

YY 400V L1 L2 L3 PTC PTC PE


Max. 2.5V
446 | Wiring Diagram

14d
ON 1U 1V 1W 2U 2V 2W NO NC PE

Low speed
OFF

Two speed electric motor


in Dahlander connection
Y 400V L1 L2 L3 PE
(4-8, 6-12)
Lock the service switch
in position ON to prevent
ON 1U 1V 1W 2U 2V 2W NO NC PE unintended switch OFF!
Lock is not in scope of fan.
High speed
OFF

YY 400V L1 L2 L3 PE

15a
ON 1U 1V 1W 2U 2V 2W NO NC PE

Low speed
OFF

Two speed electric motor (4-6, 6-8, 8-12)


Y 400V L1 L2 L3 PE Lock the service switch in position ON to
prevent unintended switch OFF!
Lock is not in scope of fan.
ON 1U 1V 1W 2U 2V 2W NO NC PE

High speed
OFF

Y 400V L1 L2 L3 PE

15b 15c

ON U1 V1 W1 NO NC PE ON U1 V1 W1 PTC PTC NO NC PE

OFF OFF

Y 400V L1 L2 L3 PE Y 400V L1 L2 L3 PTC PTC PE


Max. 2.5V

Single speed electric motor. Single speed electric motor.


Lock the service switch in position ON to prevent Lock the service switch in position ON to prevent
unintended switch OFF! unintended switch OFF!
Lock is not in scope of fan. Lock is not in scope of fan.
diagram
Wiring
Wiring Diagram | 447

15d 15e

Y 400V 1U 1V 1W 2U 2V 2W

400V

Y 400V 1U 1V 1W 2U 2V 2W

16 16a
Three phase motor in delta connection with
thermostatic switch (TB). Changing of rota-
Delta connection Star connection tion direction by interchanging of 2 phases.
V2 U2 W2
TB TB W1 V1 U1
U1 = brown
V1 = blue
W1 = black
U2 = red
V2 = grey
W2 = orange
TB = white
PE = yellow-
TB TB L3 L2 L1 PE green

17a 17b

Delta connection Delta connection


Low speed connection Low speed connection
3 x 230V 3 x 400V

L1 L2 L3 PE TK/PTC L1 L2 L3 PE TK/PTC

Star connection Star connection


High speed connection High speed connection
3 x 400V 3 x 690V

L1 L2 L3 PE TK/PTC L1 L2 L3 PE TK/PTC

17c

High speed connection

L1 L2 L3 PE TK
diagram
Wiring

Low speed connection

L1 L2 L3 PE TK
448 | Wiring Diagram

18a 18b

High speed
Delta connection
Δ-Connection
TB TB W2 U1 U2 V1 V2 W1

L2 L1 L3 PE

Low speed
Star connection TB TB W2 U1 U2 V1 V2 W1
Y-Connection

L2 L1 L3 PE

19 20

High speed Low speed

Delta connection

U1 = blue
U2 = black
Star connection Z = brown

21
diagram
Wiring
Wiring Diagram | 449

23a 23b

black black
Net voltage L L Net voltage L L
blue blue
N N N N
green/yellow green/yellow
1-200-277V PE PE 1-200-277V PE PE

white
NC
white
COM
Error signal relay, COM
white (2A, 250 VAC)
Tacho
red red
+10V Exit +10V Exit
+ yellow + yellow
0-10V Inlet 0-10V Inlet
P1 blue
0-10V -
GND 0-10V - P1 blue
GND
External signal 10k External signal 10k
Potentiometer Motor Potentiometer Motor

24

Pressure control

GND 10
Operation

Night 9
mode

GND 8
Day 7
GND 6
Input

0-10V in 5
Mains 1 1 PE +10V 4
Mains

200-277 VAC 2 N GND 3


EC-motor

50/60 Hz 3 L 0-10V out 2


Fan

1 PE Tacho in 1
EC-motor

2 N
Fan

3 L 3
2 Fan EC-motor
1 1
Alarm relay

074/084
2 red
Alarm relay 1 GND 2 +10V
blue
Normally closed contact 2 +20V in 1 GND
yellow
0-10V

white 1
NC
white 2
COM Error signal relay,
blue
L COMMON
black
N (2A, 250 VAC)
green/yellow
PE
diagram
Wiring
450 | Wiring Diagram

25
Pressure control

GND 10 Fan EC-motor

Operation
9

mode
GND 8 112
12 RS A
7 11 RS B
GND 6 10 RS A

Input
5 9 RS B
1 PE +10V 4 8 GND

Mains
2 N GND 3 7 0-10V

EC-motor
KL.3
3 L 2 6 4-20mA

Fan
1 PE 1 5 +20V

EC-motor
2 N 4 +10V

Fan
3 L 3 3 0-10V
2 2 GND
1 1 1 OUT

Alarm relay
2
Alarm relay 1 GND 2
Normally closed 2 1
3 NO
contact
2 COM KL.2
1 NC

L 2 L KL.1
N 1 N
PE PE

26

Pressure control

GND 10 Fan EC-motor


Operation

9
mode

GND 8 112/150
12 RS A
7 11 RS B
GND 6 10 RS A
Input

5 9 RS B
1 PE +10V 4 8 GND
Mains

2 N 7 0-10V
EC-motor

GND 3 KL.3
3 L 2 6 4-20mA
Fan

1 1 5 +20V
EC-motor

PE
2 N 4 +10V
Fan

3 L 3 3 0-10V
2 2 GND
1 1 1 OUT
Alarm relay

2
Alarm relay 1 GND 2
Normally closed 2 1
3 NO
contact
2 COM KL.2 Error signal relay,
1 NC COMMON
(2A, 250 VAC)

L1 3 L1
KL.1
L2 2 L2
L3 1 L3
PE PE
diagram
Wiring
Wiring Diagram | 451

27

12 RS A Interface RS485 for ebmBUS


11 RS B Interface RS485 for ebmBUS
10 RS A Interface RS485 for ebmBUS
9 RS B
Interface RS485 for ebmBUS
8 GND GND
7 0-10V Control-/Actual value inlet
Kl. 3 / class 3
6 4-20mA Control-/Actual value inlet
5 +20V Supply ext. sensor 50mA
4 +10V Supply ext. potentiometer 10mA
+
3 0-10V Control/Actual value inlet
0-10V - P1
2 GND GND
10k
1 OUT Master exit 0-10V max 3mA
External signal Potentiometer

3 NO Error signal relay, closer in the case of error


Kl. 2 / class 2 2 COM Error signal relay, COMMON (2A, 250 VAC)
1 NC Error signal relay, opener in the case of error

3 L1 Net, L1
2 L2 Net, L2
Kl. 1 / class 1
1 L3 Net, L3
PE Protective conductor

28 29
12 RS A Interface RS485 for ebmBUS

11 RS B Interface RS485 for ebmBUS

10 RS A Interface RS485 for ebmBUS

9 RS B Interface RS485 for ebmBUS

8 GND GND

7 0-10V Control-/Actual value inlet


Kl. 3 / class 3
6 4-20mA Control-/Actual value inlet

5 +20V Supply ext. sensor 50mA


yellow/green
( ) ( )
4 +10V Supply ext. potentiometer 10mA
+ (L)
3 0-10V Control/Actual value inlet
0-10V - P1
(N)
2 GND GND
black
10k
Master exit 0-10V max 3mA
(L)
External signal Potentiometer 1 OUT
blue
(N)
3 NO Error signal relay, closer in the case of error brown

Kl. 2 / class 2 2 COM Error signal relay, COMMON (2A, 250 VAC)

1 NC Error signal relay, opener in the case of error

2 L Net, L
1 N Net, N
Kl. 1 / class 1
PE Protective conductor
diagram
Wiring
452 | Wiring Diagram

30

EC controller
G2

+24V /40mA
+5V /10mA

+24V

+24V
G1 15 27
Fan
DVG-EC
F1

-+
NC F4 F6 F7
F3

G3 Service switch
F5

SO
F2 F8

Ver. 0.2

E1 E2 E3

Wiring description Terminal description


Symbol Description Marking Terminal Description
No.
G1 Fan DVG-EC
Mains supply PE 1 PE connection
G2 EC controller
N 2
G3 Service switch ON-OFF, 6 pole + 1xNC
L 3 Supply voltage 1~ 230V/50-60Hz
F1 Fault relay
Fault relay NC 4 Normally close
F2 Analog input for set value / speed setting
COM 5 Common connection; contact rating
F3 Potentiometer for speed setting
250V/5A
F4 External sensor
NO 6 Normally open
F5 Speed output
User interface An1 7 Analog input 1; set value 0-10V; R
F6 FIRE mode (open = FIRE) >= 1kΩ
F7 Start /Stop switch (open = stop) GND 8, 12, 14 I/O ground
F8 Bus connection Pot 9 Potentiometer output (3 wires)
E1 Power supply - connection in G3 +5V 10 +5V +/-5% / 10mA for potentiom-
eter
Max. cable crosssection: 2,5 mmq (4
mmq without core end sleeves) An2 11 Analog input 2 for external sensor
Max. cable diameter: 13 mm +24V 13, 16, +24V +/- 5% DC (unregulated) volt-
19 age / Imax 40 mA
Cable gland on supply side included:
1xM20x1,5 Speed 15 Digital output; speed output PWM
signal
Possible to install additional cable glands f ~ 1,1 kHz; NPN open collector
1xM20x1,5, 1xM16x1,5 output
E2 Control cables - connection in G2 Fire 17 Digital input; FIRE mode
Max. cable crosssection: 1,5 mmq enabling function - open pin
disabling function - bridge to +24V
Max. cable diameter: 13 mm
Cable glands on controller: 2xM20x1,5 Start/ 18 Digital input; start/stop
Stop start - bridge to +24V
Protecting tube to provide control cables: stop - open pin
inside diameter 15,5 mm, connection
M20x1,5 male thread A 20, 22 Bus connection RS485 - A; MODBUS
RTU
E3 EC-Motor pre-wired
B 21, 23 Bus connection RS485 - B; MODBUS
RTU
diagram

Motor con- PE, U, 24, 25, Motor pre-wired


Wiring

nection V, W 26, 27
Wiring Diagram | 453

31

EC controller G1

+24V/50mA
Fan

Start/Stop
G2
DVG-EC

+10V/
15mA
COM

FIRE
An1

An2
NO
NC

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 M1 M2 M3 M4 M5 M6 PE L1 L2 L3

F1 F2 F3 G3
Service
1 2 3 4 5 6 switch
-+ F7
SO

NC
R>1k
A1 B1 A2 B2
F6 F8
-+ F5
Vcc
0-10V F4
PE L1 L2 L3
R
E2 E3 E1

Wiring description Terminal description


Symbol Description Marking Terminal Description
No.
G1 Fan DVG-EC
Fault relay NC 1 Normally close
G2 EC controller
COM 2 Common connection; contact rating
G3 Service switch ON-OFF, 6 pole + 1xNC
250V/5A
F1 Fault relay
NO 3 Normally open
F2 Speed output
User interface Speed 4 Digital output; speed output PWM signal
F3 Potentiometer for speed setting f ~ 1,1 kHz; NPN open collector output
F4 Analog input for set value / speed setting GND 5, 9, 13 I/O ground
F5 External sensor An1 6 Analog input 1; set value 0-10V; R >= 1kΩ
F6 FIRE mode (open = FIRE) +10V 7 +10V +/-5% / 15mA
F7 Start /Stop switch (open = stop) An2 8 Analog input 2 for external sensor
F8 Bus connection Fire 10 Digital input; FIRE mode
enabling function - open pin
E1 Power supply - connection in G3
disabling function - bridge to +24V
Max. cable crosssection: 2,5 mmq (4 +24V 11 +24V +/- 5% DC / Imax 50 mA
mmq without core end sleeves)
Start/ 12 Digital input; start/stop
Max. cable diameter: 13 mm Stop start - bridge to +24V
Cable gland on supply side included: stop - open pin
1xM20x1,5 A 14, 16 Bus connection RS485 - A; MODBUS RTU
Possible to install additional cable glands B 15, 17 Bus connection RS485 - B; MODBUS RTU
1xM20x1,5, 1xM16x1,5
Motor con- M1-M6 M1-M6 Motor pre-wired
E2 Control cables - connection in G2 nection
Max. cable crosssection: 1,5 mmq Mains supply PE PE PE connection
Max. cable diameter: 13 mm L1, L2, L1, L2, L3 Supply voltage 3~ 400V/50-60Hz
L3
Cable glands on controller: 2xM20x1,5
Protecting tube to provide control cables:
inside diameter 15,5 mm, connection
M20x1,5 male thread
E3 EC-Motor pre-wired
diagram
Wiring
454 | Wiring Diagram

41 42

230V 1~ Internal potentiometer,


Wiring power cable Internal potentiometer,
default
default
N L

yellow
white

blue

red

yellow
white

blue

red
N L 1 2 3 4

- +
1=Min 5 - +
1=Min 5
0 10
0 10

43 44a
400V 3~ (Y)

TP3/4 PE W2 U1 U2 V1 V2 W1 PE

X2 X1
TP TP U V W

TP3/4 PE L1 L2 L3 PE
L1 L2 L3 PE
PTC

44b 45
400V 3~ (D)
U V W TP3 TP4 PE
TP3/4 PE W2 U1 U2 V1 V2 W1 PE

X2 X1

TP3/4 PE L1 L2 L3 PE R S T TP3 TP4 PE


diagram

PTC
Wiring

[L1 L2 L3 PTC PE]


Wiring Diagram | 455

46
Line 1 Line 2

COM

GND
+10V

0-10V
PWM
NC
PE
N
L

Black Blue Green/yellow White1 White2 Red Yellow Blue

Line Connection Colour Assignment/function Line Connection Colour Assignment/function


1 L black Mains 50/60 Hz, phase 2 +10V red Voltage output +10V max 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10V/PWM yellow Control input (impendence 100 kW)
PE green/yellow Protective earth GND blue Protective earth
NC white1 Alarm relay, break for failure
COM white2 Alarm relay, COMMON

47
KL3 KL2 KL1
Ain1 U Ain2 U

Ain2 I
Din 2

Din 3

+20V
GND

Aout
Ain1 I

Din 1

COM
RS B
RS A

GND

+10V

NC

PE
No

L1

L2

L3
Connector Connection Assignment/function Connector Connection Assignment/function
KL1 L3 Mains, L3 Digital input (enabling/disabling of elec-
L2 Mains, L2 tronics). Enabling: Pin open or applied volt-
KL3 Din1
age 5...50 VDC. Disabling: Bridge to GND or
L1 Mains, L1 applied voltage < 1 VDC.
PE PE Protective earth Analogue set value input 4-20 mA (impe­
KL2 NC Alarm relay, break for failure Ain1 I dance 100W), only to be used as alternative
COM Alarm relay, COMMON (2A, 250VAC, AC1) to terminal Ain1 U.
NO Alarm relay, make for failure Supply for external potentiometer, 10 VDC
+10V
(±3%) max. 10 mA.
Analogue set value input, 0-10V (impe­
Ain1 U dance 100 kW), only to be used as alterna-
tive to terminal Ain1 I.
GND GND
RSB RS485 interface for MODBUS RTU; RS B
RSA RS485 interface for MODBUS RTU; RS A
Analogue output 0-10V max 5 mA, reading
Aout of current motor speed/current motor
control factor.
Analogue actual value input, 4-20 mA
Ain2 I (impedance 100kW, only to be used as
alternative to terminal Ain2 U.
Supply for external sensor, 20 VDC (+25%/-
+20 V
10%) max. 40 mA.
Analogue actual valve input, 0-10 V (im-
Ain2 U pedance 100kW only to be used as alterna-
tive to terminal Ain2 I.
GND GND
Digital input 3 (switch normal/inverse). The
preset effective direction of the integrated
controller can be selected via BUS or via
Din3
digital input normal//inverse. Normal: Pin
open or applied voltage 5...50 VDC. Inverse:
Bridge to GND or applied voltage < VDC.
diagram
Wiring

Digital input 2 (switch day/night). The preset


set of parameters can be selected via BUS
Din2 or digital input day/night. Day: Pin open or
applied voltage 5...50 VDC. Night: Bridge to
GND or applied voltage < 1 VDC.
456 | Wiring Diagram

48
KL3 KL2 KL1

4-20mA
0-10 V

0-10 V
+20 V

+10 V

COM
RS B

RS B
RS A
RS A

GND

GND
PWM

PWM

OUT

PE
NO

N
NC

L
Connector Connection Assignment/function Connector Connection Assignment/function
KL3 OUT Master output 0-10 V max 3 mA. PE OE Jord
GND GND KL1 N Nät 50/60Hz, neutral
0-10V/PWM Control/Actual valve input (impedans 100 kW). L Nät 50/60Hz, fas
Supply for external potentiometer, 10 VDC KL2 NC Alarm relay, break for failure
+10V
(+10%) max 10 mA COM Alarm relay, COMMON (2A, 250 VAC,
Supply for external sensor, 20 VDC (+20%/- AC1)
+20V
10%) max 50 mA NO Alarm relay, make for failure
4-20 mA Control/actual valve input
0-10V/PWM Control/actual valve input
GND GND
RSB RS485 gränssnitt för ebmBUS; RS B
RSA RS485 gränssnitt för ebmBUS; RS A
RSB RS485 gränssnitt för ebmBUS; RS B
RSA RS485 gränssnitt för ebmBUS; RS A

49

TB TB U1 Z U2

L N PE

50
Customer circuit Interface Fan / motor
max. Adjustable
speed speed

10 V -> n = max
1 V -> n = min
<1 V -> n = 0

Adjustable speed Adjustable speed


setting via PWM setting via
1-10 kHz Potentiometer

Line No. Signal Colour Function / assignment


CON10 L black Power supply 230 VAC, 50-60 Hz, for voltage range refer to rating plate
CON11 N blue Neutral conductor
CON12 PE green/yellow Protective earth
diagram

1 GND blue GND - Connection for control interface


Wiring

2 0- 10V PWM yellow Control input 0 - 10 V or PWM, electrically isolated


3 10V/ max 1.1mA red Voltage output 10V/ 1.1mA, electrically isolated, not short-circuit-proof.
4 Tach white Tach output: open collector, 1 pulse per revolution, electrically isolated
Wiring Diagram | 457

52

Customer circuit Connection Fan / motor


Notes on various control possibilities and their applications

Umin +15 V
black L 6.3 AT
Imax
blue N Fuse
10 mA UN 230 VAC
green/yellow PE

PE
white 1 NC

PWM white 2 COM Alarm relay Break for failure


10 K U
red +10V max. 1.1 mA
12 V Voltage output
yellow 0-10 V PWM * 47 K
PWM / lin control input 1 µF
47 K
blue GND
Speed Speed Full speed Speed
setting setting with setting
variable
* PWM 1 - 10 kHz resistance 1 V - 10 V
100% PWM -> n = max
typ. 10% PWM -> n = min 10 V -> n = max
< 10% PWM -> n = 0 1 V -> n = min
<1 V -> n = 0

53
Customer circuit Connection Fan / motor
Full Adjustable
speed speed

10 V -> n = max
1 V -> n = min
<1 V -> n = 0

Set value Adjustable


e.g. for pressure speed above
potentiometer

No. Pin Signal Function / assignment


PE PE Protective earth connection
KL1 1, 2, 3 L1, L2, L3 Supply voltage, voltage range (see type plate), 50/60 Hz
KL2 1 NC Floating status contact, break with error
KL2 2 COM Floating status contact, changeover contact, common connection (2 A, max. 250 VAC,
min. 10 mA, AC1)
KL2 3 NO Floating status contact, close with error
KL3 1 OUT Analogue output, 0-10 VDC, max. 3 mA, SELV,
Output of the actual motor duty cycle (PWM):
1 V corresponds to 10% PWM,
10 V correspond to 100% PWM.
KL3 2, 8 GND Signal ground for control interface, SELV
KL3 3, 7 0-10 V Set value / actual sensor value input 0-10 VDC, impedance 100 kΩ only as alternative to 4-20 mA input,
SELV
KL3 4 +10 V Voltage output 10 VDC (+/-3%), max. 10 mA,
power supply for external devices (e.g. potentiometer), SELV
diagram
Wiring

KL3 5 +20 V Voltage output 20 VDC (+25%/-10%), max. 50 mA, supply voltage for external devices
(e.g. sensors), SELV
KL3 6 4-20 mA Set value / actual sensor value input 4-20 mA, impedance 100 Ω, only as alternative to 0-10 V input, SELV
KL3 9, 11 RSB RS485 interface for MODBUS, RSB
KL3 10, 12 RSA RS485 interface for MODBUS, RSA
458 | Wiring Diagram

54

Customer circuit Connection Fan / motor


Full speed Speed KL3
setting RSA
RSB
RSA
RSA
RSB
RSB
GND
IN
10 V -> n = max 0-10V/PWM
1 V -> n = min
<1 V -> n = 0
4-20mA
+20V/50mA
20V
+10V/10mA
10V
0-10V/PWM
GND
Set value input, Speed setting via OUT
e.g. via pressure potentiometer
OUT
KL2
GND
NO
COM
NC

KL1
L

PE
PE
PE

No. Pin Signal Function / assignment


PE - PE Protective earth connection
KL1 1, 2 N, L Supply voltage, 50/60 Hz
KL2 1 NC Floating status message contact, break for failure
KL2 2 COM Floating status message contact, changeover contact, common connection
(2 A, max. 250 VAC, min. 10 mA, AC1)
KL2 3 NO Floating status message contact, normally open, make for failure
KL3 1 OUT Analogue output, 0-10 VDC, max. 3 mA, SELV,
Output of the current motor level control coefficient:
1 V corresponds to 10% level control coefficient,
10 V correspond to 100% level control coefficient.
KL3 2, 8 GND Reference mass for control interface, SELV
KL3 3, 7 0-10 V Use control / actual value input 0-10 VDC, impedance 100 kΩ only as alternative to 4-20 mA input, SELV
KL3 4 +10 V Voltage output 10 VDC (+/- 3%), max. 10 mA,
Supply voltage for ext. devices (e.g. potentiometer), SELV
KL3 5 +20 V Voltage output 20 VDC (+25%/-10%), max. 50 mA
Supply voltage for ext. devices
(e.g. sensors), SELV
KL3 6 4-20 mA Use control / actual value input 4-20 mA, impedance100 Ω, only as alternative to 0-10 V input, SELV
KL3 9, 11 RSB RS485 interface for MODBUS, RSB
KL3 10, 12 RSA RS485 interface for MODBUS, RSA
diagram
Wiring
Wiring Diagram | 459

55

Ain 2 U
+ 20 V
Ain 2l
Din 2
Din 3

Aout
GND
Ain 1 U
+ 10 V
Ain 1 l
Din 1

COM
GND
RSA
RSB

NO

NC

PE

L1
L2
L3
1
2
3
4
5
6
7

1
2
3

1
2
3
KL 3 KL 2 PE KL 1
No. Pin Signal Function/assignment
KL 1 1 L1 Mains supply connection, supply voltage 3~380-480 VAC; 50/60 Hz
KL 1 2 L2 Mains supply connection, supply voltage 3~380-480 VAC; 50/60 Hz
KL 1 3 L3 Mains supply connection, supply voltage 3~380-480 VAC; 50/60 Hz
PE PE Earth connection, PE connection
KL 2 1 NO Status relay, floating status contact; normally open; close with error
KL2 2 COM Status relay; floating status contact; changeover contact; common connection; contact rating
250 VAC / max. 2 A (AC1) / min. 10 mA
KL2 3 NC Status relay, floating status contact; break with error
KL3 1 RSA Bus connection RS485; RSA; MODBUS RTU
KL3 2 RSB Bus connection RS485; RSB; MODBUS RTU
KL3 3/10 GND Signal ground for control interface KL3
KL3 4 Ain1U Analogue input 1 (set value); 0-10 V; Ri=100 kΩ; parametrisable curves; only usable as alternative to
input Ain1 I
KL3 5 +10V Fixed voltage output 10 VDC; +10 V +/-3%; max.10 mA; short circuit proof; power supply for ext.
devices (e.g. potentiometer)
KL 3 6 Ain1I Analogue input 1 (set value); 4-20 mA; Ri=100 Ω; parametrisable curves; only usable as alternative to
input Ain1 U
KL3 7 Din1 Digital input 1: enabling of electronics; enabling: open pin or applied voltage 5 to 50 VDC; disabling: bridge
to GND or applied voltage < 1 VDC; reset function: triggers software reset after a level change to < 1V
KL3 8 Din2 Digital input 2: parameter set switch 1/2; according to EEPROM setting, the valid/used parameter set is
selectable per BUS or per digital input DIN2. Parameter set 1: open pin or applied voltage 5 to 50 VDC;
parameter set 2: bridge to GND or applied voltage < 1 VDC
KL3 9 Din3 Digital input 3: Control characteristic of the integrated controller; according to EEPROM setting, the control
characteristic of the integrated controller is normally/inversely selectable per BUS or per digital input;
normal: open pin or applied voltage 5 to 50 VDC (control deviation = actual sensor value - set value)
inverse: bridge to GND or applied voltage < 1 VDC (control deviation = set value - actual sensor value)
KL3 11 Ain2U Analogue input 2; actual sensor value 0-10 V; Ri=100 kΩ; parametrisable curve; only usable as
alternative to input Ain2 I
KL3 12 +20V Fixed voltage output 20 VDC; +20 V +25/-10%; max. 50 mA; short circuit proof; power supply
for ext. devices (e.g. sensors)
KL3 13 Ain2I Analogue input 2; actual sensor value 4-20 mA; Ri=100 Ω; parametrisable curve; only usable as
alternative to input Ain2 U
KL3 14 Aout Analogue output 0-10 V; max. 5 mA; output of the actual motor control factor (output voltage of
electronics)/ of the actual motor speed; function selectable per bus; parametrisable curve.
diagram
Wiring
460 | Wiring Diagram

56

57
Customer circuit Connection Fan / motor
max. adjustable
speed speed L P
AC1
2
6 7 N 3,15 AT
N
3
AC2
1-10V
PE
1
7 4
PE1
10V -> n=max
1V -> n=min
<1V -> n=0 +10V
6
lmax=1.1mA

10 VPMW
7
47K 47K 1 F
adjustable adjustable GND
Speed setting via PWM Speed above Potentiometer 4
1-10 kHz
15V
Tach 3 1
6 5
680R
2
Imax=10mA ZMM47 4

7 7
10K
12V

4 4
100% PWM -> n=max
10% PWM -> n=min
< 10% PWM-> n=0
diagram
Wiring
Wiring Diagram | 461

58
Internal potentiometer External speed setting

D1 D1
10V 10V

E1 E1 E1
0-10V DC
GND GND
3

10kΩ
24V 24V
2
11 11
1 1 1 11 & 14 = Alarm
14 14 For operation the relay is energized connections “11
and 14” are bridged.
N N
For fault the relay is de-energized (diagnostics/faults).
L L Contact rating max. AC 250V 2A.

2 External potentiometer

3 External input DC 0...10V

59
Internal potentiometer External speed setting

D1 D1

10V 10V

E1 E1 E1
0-10V DC
GND GND 3
10kΩ

24V 24V 2

L3 L3

L2 L2 1 11 & 14 = Alarm
For operation the relay is energized connections “11
L1 L1
and 14” are bridged.
11 11 For fault the relay is de-energized (diagnostics/faults).
1 1 Contact rating max. AC 250V 2A.
14 14
2 External potentiometer

3 External input DC 0...10V

60
Internal potentiometer External speed setting

green D1 green D1
red 10V red 10V
yellow E1 yellow E1 E1
0-10V DC
blue GND blue GND 3
10kΩ

white A1 white A1 2
grey 1 11 & 14 = Alarm
grey A2 A2
For operation the relay is energized
white 11 white 11 connections “11 and 14” are bridged.
1 1 For fault the relay is de-energized
white 14 white 14 (diagnostics/faults).
blue N blue N Contact rating max. AC 250V 2A.
diagram
Wiring

brown L brown L
2 External potentiometer
yellow/ yellow/
green green External input DC 0...10V
3
462 | Index

Index
A DKEX........................................................ 242 FXDM....................................................... 371
AES........................................................... 383 DKM-2K................................................... 385
AJ8........................................................... 312 DKT-3....................................................... 385 G
AJR TR...................................................... 310 DS............................................................. 399 GFL........................................................... 399
ALS-KBT.................................................. 414 DS-EX....................................................... 434 GFL-AR/AXC............................................ 437
AMM-2.................................................... 385 DSG.......................................................... 366 GFL-AR/AXCBF....................................... 437
AQUA 24TF............................................. 376 DSK.......................................................... 414
ARM-1..................................................... 385 DTV.......................................................... 378 H
AR sileo................................................... 210 DVC / DVCI.............................................. 170 HR1.......................................................... 378
ASF........................................................... 415 DVEX........................................................ 246 HSDV........................................................ 426
ASF-DVP.................................................. 439 DVG EC.................................................... 280
ASF/KB.................................................... 414 DVG/F...................................................... 284 I
ASFV........................................................ 429 DVN / DVNI............................................. 188 IF............................................................... 352
ASK, ASK/F, ASG/F................................ 418 DVP.......................................................... 328 IGC............................................................ 388
ASS........................................................... 415 DVS.......................................................... 184 IGK............................................................ 388
ASS-DVP.................................................. 439 DVSI......................................................... 184 IR24-P..................................................... 368
ASS-EX.................................................... 434 DVSI sileo................................................ 176 IS.............................................................. 434
ASSG/F.................................................... 429 DVS sileo................................................. 176 ISE............................................................ 434
ASS-P....................................................... 440 DVV.......................................................... 194 IV (B)........................................................ 314
ASSV, ASSV/F.......................................... 428 DVV-EX.................................................... 250
ASSV-EX.................................................. 434 DVV/F...................................................... 272 K
AWE-SK................................................... 372 DVV-XS, XL.............................................. 278 K................................................................. 36
AW-EX..................................................... 254 DXRE........................................................ 405 KBR.......................................................... 340
AW sileo.................................................. 208 KBR EC..................................................... 334
AW sileo EC............................................. 202 E KBR/F...................................................... 266
AXC.......................................................... 220 EC-Vent control board........................... 365 KBT........................................................... 340
AXC (B), AXR (B).................................... 302 EC-Vent room unit................................. 366 KBT EC..................................................... 334
AXCBF...................................................... 226 EFD........................................................... 411 KD............................................................... 60
AXCBF-EX................................................ 262 EGS........................................................... 412 KD EC......................................................... 56
AXC-EX.................................................... 258 ESD-F....................................................... 438 KDRD........................................................ 144
AXC (F), AXR (F).................................... 304 ESDV........................................................ 429 KDRE........................................................ 144
EV-AR/AXC.............................................. 436 KE............................................................... 88
B EV-EX/AXC.............................................. 435 K EC............................................................ 32
BDS.......................................................... 440 EVH.......................................................... 436 K-FST1..................................................... 380
BF............................................................. 352 EX............................................................. 234 K-LSW230............................................... 380
BF-W........................................................ 350 EX connection box................................. 380 KPB.......................................................... 118
BS............................................................. 435 KT............................................................... 92
BTG.......................................................... 415 F KTEX......................................................... 238
BVK.......................................................... 440 FDGE, FDGE/F......................................... 424 KV............................................................... 36
FDG/F...................................................... 418 KVB/F...................................................... 292
C FDS........................................................... 420 KVK............................................................ 68
Cable gland set...................................... 435 FDVE, FDVE/F, FDVE-EX........................ 420 KVK DUO................................................... 74
CB............................................................. 393 FDV, FDV/F, FDV-EX............................... 420 KVKE.......................................................... 82
CBF........................................................... 352 FEP-AP..................................................... 385 KVKE EC..................................................... 78
CBM......................................................... 394 FET-AP..................................................... 385 KVO............................................................ 52
CCM................................................. 413, 414 FFK........................................................... 401 KVO EC....................................................... 48
CCMI......................................................... 414 FFR........................................................... 391 K-WFR...................................................... 379
CO2RT...................................................... 368 FFS........................................................... 409
CO2RT-R-D.............................................. 368 FGR.......................................................... 392 L
CWK......................................................... 398 FGV........................................................... 413 LDC........................................................... 390
CXE/AV.................................................... 369 FK............................................................. 388 LDC(B)..................................................... 390
FKX........................................................... 435 LDK........................................................... 409
D FRQ.......................................................... 361 LDR.......................................................... 400
DF-AJ........................................................ 433 FRQ5........................................................ 361 LGV/LGH.................................................. 421
DF-AJ8..................................................... 433 FRQ(5)S................................................... 362 LRK(F)...................................................... 430
Index

DHA sileo................................................ 166 FSD-AXC.................................................. 433


DHS.......................................................... 184 FSL........................................................... 426
DHS sileo................................................. 176 FTG........................................................... 415
Index | 463

M RTRE........................................................ 356
RVAZ4-24............................................... 377
TG-UH/PT1000......................................
THB..........................................................
367
416
MFA-AR/AXC.......................................... 432
RVK-EX.................................................... 232 THS........................................................... 417
MFA-AXCBF............................................ 432
RVK sileo................................................... 42 TM 10...................................................... 378
MicroREX D21........................................ 379
TOB.......................................................... 416
MP............................................................ 432
MPR......................................................... 431
S TOS........................................................... 416
S2S 160.................................................. 381 Trafo 15/D.............................................. 378
MSEX....................................................... 373
S5S 100T1.............................................. 381 TTC........................................................... 375
MTP 10.................................................... 359
S5S 100T3.............................................. 381 TT-S1....................................................... 376
MTP 20.................................................... 360
Safety-Anchor........................................ 433 TT-S4/D................................................... 376
MTV 1/010............................................. 359
SC1/D...................................................... 379 TUB/TUS.................................................. 416
MUB......................................................... 132
SC2/D...................................................... 379
MUB EC................................................... 124
MUB/F..................................................... 296
SD-AXC.................................................... 433 U
SDM......................................................... 412 U-EK 230E EX......................................... 374
MUB/T..................................................... 152
SD-PRF.................................................... 439 UGF.......................................................... 414
MUB/T EC................................................ 148
S-DT2 DKT............................................... 381 UGS.......................................................... 413

O S-DT2 GKT...............................................
S-DT2 SKT...............................................
381
381
US.............................................................
USE...........................................................
434
434
Optigo OP 5............................................ 367
S-ET 10.................................................... 373
Optigo OP 10......................................... 367
ORH.......................................................... 399
S-ET 10E.................................................. 373 V
SF 24A..................................................... 382 VBC.......................................................... 395

P SF 24A-S2...............................................
SF 24A-SR...............................................
382
382
VBF........................................................... 396
VBK.......................................................... 408
prioAir........................................................ 28
SF 230A.................................................. 382 VBR.......................................................... 406
PGK.......................................................... 404
SG............................................................. 389 VK.................................................... 389, 412
PKDM12.................................................. 363
SG AR/AXC.............................................. 431 VKA-P...................................................... 440
PRF........................................................... 322
SG AW...................................................... 431 VKG/F...................................................... 428
prio mounting bracket.......................... 389
SG AW-D................................................. 431 VKK.......................................................... 392
Pulser....................................................... 374
SM 230A................................................. 382 VKM......................................................... 427
Pulser M.................................................. 375
SRK........................................................... 399 VKS........................................................... 427
PXDM....................................................... 364
SRKG........................................................ 413 VKS-DVP.................................................. 439

R SSD...........................................................
SSGE, SSGE/F.........................................
419
424
VKS-EX.................................................... 427
VKS-P....................................................... 440
RADT........................................................ 359
SSG, SSG/F.............................................. 423 VKSV-EX.................................................. 427
RB............................................................. 402
SSVE, SSVE/F, SSVE-EX......................... 422 VKVE/F.................................................... 428
RBK.......................................................... 410
SSV, SSV/F, SSV-EX................................ 425 VKV/F....................................................... 428
RBM......................................................... 403
STDT 16................................................... 373 VKVM....................................................... 429
R-DK4 KT (EX)........................................ 360
STDT 16E................................................. 373 VP............................................................. 439
RE............................................................. 356
STG........................................................... 417
RED.......................................................... 410
REE........................................................... 357
W
REE S0..................................................... 358
T WBK......................................................... 414
T 120....................................................... 378 WSD......................................................... 413
REE TR0................................................... 358
TDA DV.................................................... 415 WSD-KBT................................................. 414
REPT......................................................... 371
TDS........................................................... 381 WSD PRF................................................. 440
RETP......................................................... 370
TES........................................................... 381 WSG......................................................... 413
REU.......................................................... 356
TFR........................................................... 372 WVA......................................................... 318
REV........................................................... 380
TFSR EC / TFSK EC................................. 160 WVI.......................................................... 318
REV ATEX................................................. 381
TFSR / TFSK............................................ 162
REV incl. EMC KIT................................... 380
RS............................................................. 102
TG............................................................. 417 Z
TG 300-800, 400-800......................... 417 ZRS........................................................... 198
RSA (F).................................................... 430
TG-A 130................................................ 377 ZSD-AXC.................................................. 433
RS EC......................................................... 98
TG-D130................................................. 377 ZTR/ZTRB................................................ 441
RSI............................................................ 112
TG-K330.................................................. 377 ZTV/ZTVB................................................ 441
RSI EC...................................................... 108
TG-KH/PT1000...................................... 367
RSK........................................................... 388
TG-R4/R5/PT1000................................ 367
RT 0-30................................................... 377
TG-R430/530......................................... 377
RTRD........................................................ 357
TG-R600/630......................................... 377
RTRDU..................................................... 357
Index
www.systemair.com
Systemair AB • December 2013 • E8240

Вам также может понравиться