INSTRUCTIONS AND
OWNER'S MANUAL
DIRECT VENT
WALL FURNACE
STANDARD MODELS:
HWDV081(N,P)-1
HWDV150(N,P)-1
MODELS WITH BLOWER:
HWDV081B(N,P)-1
HWDV150B(N,P)-1
GAS-FIRED
Page 1
TABLE OF CONTENTS
SECTION PAGE
Carton Contents.............................................................................................3
Hardware Packets..........................................................................................4
Tools Needed..................................................................................................5
Gas Specifications.........................................................................................6
Specifications.................................................................................................6
High Altitude Specifications..........................................................................6
Unit Dimensions.............................................................................................7
Important Safety Information................................................................ 8 - 10
Safety Information for Users of LP-Gas.....................................................11
Introduction...................................................................................................12
Requirements for Massachusetts...............................................................13
Termination Clearances...............................................................................14
Gas Supply............................................................................................ 15 - 16
Clearances....................................................................................................16
Installation Location.....................................................................................17
Installation Overview........................................................................... 18 - 19
Interior Installation............................................................................... 20 - 25
Cutting the Vent Tubes......................................................................... 26 - 27
Exterior Installation of the Venting..................................................... 28 - 30
Reassembly and Resealing Venting System..................................... 31 - 33
Installation of Optional Blower Kit HW125SCB................................. 34 - 37
Before Operating Appliance........................................................................38
Operating Instructions.................................................................................39
Lighting Instructions....................................................................................40
To Turn Off Gas To Appliance.....................................................................40
Pilot Flame Characteristics.........................................................................41
Main Burner Flame Characteristics............................................................41
Maintenance Instructions............................................................................42
Troubleshooting...........................................................................................42
How To Order Repair Parts..........................................................................43
Parts View.....................................................................................................44
Parts List.......................................................................................................45
Warranty Information...................................................................................46
Appliance Service History...........................................................................47
Page 2 33444-0-0414
CARTON CONTENTS
33444-0-0414 Page 3
HARDWARE PACKETS
HEATER
HARDWARE PACKET
VENT KIT
HARDWARE PACKET
#10 X ½” PHILLIPS HEX HEAD SCREW (3) #10 X 2 ½” HEX HEAD SCREW (4)
Page 4 33444-0-0414
TOOLS NEEDED
Note: Additional tools may be required depending on the exterior construction materials used on the home.
33444-0-0414 Page 5
GAS SPECIFICATIONS
MODEL FUEL INPUT
HWDV081(B) 8,000 Btu/hr
Propane/LP -- Natural gas
HWDV150(B) 15,000 Btu/hr
Natural gas: 4in water column pressure (W.C.)
MANIFOLD PRESSURE
Propane/LP gas: 10.0in W.C.
Gas Inlet 1/2 NPT
SUPPLY MINIMUM PRESSURE MAXIMUM PRESSURE
Natural Gas 5in W.C. 10.5in W.C.
LP Gas 11in W.C. 13in W.C.
Note: Appliance input ratings are based on sea level operation and need not be changed for operation up to 2,000 feet
(609.6m).
SPECIFICATIONS
MODELS HWDV081(B) HWDV150(B)
COMBUSTION ATMOSPHERIC BURNER
233 Sq ft 478 Sq ft
STANDARD HEATING SPACE
(21.65 Sq m) (44.41 Sq m)
21-11/16in 25-3/16in
HEIGHT
(550.9mm) (639.8mm)
18-5/16in 22-5/16in
EXTERNAL DIMENSIONS WIDTH
(465.1mm) (566.7mm)
9in 9-1/2in
DEPTH
(228.6mm) (241.3mm)
29 lbs 40 lbs
NET WEIGHT
(13.15 kg) (18.14 kg)
MAX. GAS CONSUMPTION 8,000 Btu/hr. 15,000 Btu/hr.
SAFETY DEVICES Safety valve (thermopile)
NOTE: This direct vent wall furnace is equipped for either Natural or Propane gas. Field conversion
kits are available for purchase by calling 877-459-1583.
Page 6 33444-0-0414
UNIT DIMENSIONS
9” (228.6mm) (HWDV081)
9-1/2” (241.3mm) (HWDV150)
33444-0-0414 Page 7
IMPORTANT SAFETY INFORMATION
Definitions:
DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury.
Page 8 33444-0-0414
IMPORTANT SAFETY INFORMATION
WARNING: Any change to this furnace or its control can be dangerous. This is a heating appliance and any
panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance.
DATA PLATE
Do not use gases other than those indicated on the heater’s
data plate label.
LIGHTING
INSTRUCTIONS
33444-0-0414 Page 9
IMPORTANT SAFETY INFORMATION
Page 10 33444-0-0414
SAFETY INFORMATION FOR USERS OF LP-GAS
Propane (LP-Gas) is a flammable gas which can cause SOME POINTS TO REMEMBER
fires and explosions. In its natural state, propane is odor- • Learn to recognize the odor of LP-gas. Your local LP-Gas
less and colorless. You may not know all the following Dealer can give you a "Scratch and Sniff" pamphlet. Use it to
safety precautions which can protect both you and your find out what the propane odor smells like. If you suspect that
family from an accident. Read them carefully now, then your LP-Gas has a weak or abnormal odor, call your LP-Gas
Dealer.
review them point by point with the members of your
household. Someday when there may not be a minute to • If you are not qualified, do not light pilot lights, perform service,
lose, everyone's safety will depend on knowing exactly or make adjustments to appliances on the LP-Gas system. If
what to do. If, after reading the following information, you are qualified, consciously think about the odor of LP-Gas
prior to and while lighting pilot lights or performing service or
you feel you still need more information, please contact
making adjustments.
your gas supplier.
• Sometimes a basement or a closed-up house has a musty
LP-GAS ODOR WARNING: smell that can cover up the LP-Gas odor. Do not try to light
pilot lights, perform service, or make adjustments in an area
If a gas leak happens, you should be able to smell
where the conditions are such that you may not detect the odor
the gas because of the odorant put in the LP-Gas. if there has been a leak of LP-Gas.
That's your signal to go into immediate action!
• Odor fade, due to oxidation by rust or adsorption on walls of
• Do not operate electric switches, light matches, use your new cylinders and tanks, is possible. Therefore, people should
phone. Do not do anything that could ignite the gas. be particularly alert and careful when new tanks or cylinders
• Get everyone out of the building, vehicle, trailer, or area. are placed in service. Odor fade can occur in new tanks, or
Do that IMMEDIATELY. reinstalled old tanks, if they are filled and allowed to set too
long before refilling. Cylinders and tanks which have been out
• Close all gas tank or cylinder supply valves.
of service for a time may develop internal rust which will cause
• LP-Gas is heavier than air and may settle in low areas odor fade. If such conditions are suspected to exist, a periodic
such as basements. When you have reason to suspect a sniff test of the gas is advisable. If you have any question about
gas leak, keep out of basements and other low areas. Stay the gas odor, call your LP-gas dealer. A periodic sniff test of the
out until firefighters declare them to be safe. LP-gas is a good safety measure under any condition.
• Use your neighbor's phone and call a trained LP-Gas ser- • If, at any time, you do not smell the LP-Gas odorant and you
vice person and the fire department. Even though you may think you should, assume you have a leak. Then take the same
not continue to smell gas, do not turn on the gas again. Do immediate action recommended above for the occasion when
not re-enter the building, vehicle, trailer, or area. you do detect the odorized LP-Gas.
• Finally, let the service man and firefighters check for es- • If you experience a complete "gas out," (the container is under
caped gas. Have them air out the area before you return. no vapor pressure), turn the tank valve off immediately. If the
Properly trained LP-Gas service people should repair the container valve is left on, the container may draw in some air
leak, then check and relight the gas appliance for you. through openings such as pilot light orifices. If this occurs, some
new internal rusting could occur. If the valve is left open, then
treat the container as a new tank. Always be sure your con-
NO ODOR DETECTED - ODOR FADE tainer is under vapor pressure by turning it off at the container
Some people cannot smell well. Some people cannot smell the before it goes completely empty or having it refilled before it is
odor of the chemical put into the gas. You must find out if you can completely empty.
smell the odorant in propane. Smoking can decrease your ability to
smell. Being around an odor for a time can affect your sensitivity or
ability to detect that odor. Sometimes other odors in the area mask
the gas odor. People may not smell the gas odor or their minds are
on something else. Thinking about smelling a gas odor can make
it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some
circumstances. For example, if there is an underground leak, the
movement of the gas through soil can filter the odorant. Odorants in
LP-Gas also are subject to oxidation. This fading can occur if there
is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That will
take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could
vary at different levels. Since it is heavier than air, there may be
more odor at lower levels. Always be sensitive to the slightest gas
odor. If you detect any odor, treat it as a serious leak. Immediately
go into action as instructed earlier.
33444-0-0414 Page 11
INTRODUCTION
Always consult your local Building Department regarding Qualified Installing Agency
regulations, codes or ordinances which apply to the instal- Installation and replacement of gas piping, gas utilization
lation of a direct vent wall furnace. equipment or accessories and repair and servicing of equip-
ment shall be performed by a qualified agency. The term
Instructions to Installer
“qualified agency” means any individual, firm, corporation
1. Installer must leave instruction manual with owner after
or company which either in person or through a representa-
installation.
tive is engaged in and is responsible for (1) the installation
2. Installer must have owner fill out and mail warranty card
or replacement of gas piping or (2) the connection, instal-
supplied with furnace.
lation, repair or servicing of equipment, who is experienced
3. Installer should show owner how to start and operate
in such work, familiar with all precautions required and has
furnace and thermostat.
complied with all the requirements of the authority having
jurisdiction.
Warning:
Any change to this furnace or its control can be dan- State of Massachusetts: The installation must be made
gerous. This is a heating appliance and any panel, by a licensed plumber or gas fitter in the Commonwealth
door or guard removed for servicing an appliance of Massachusetts. The state of Massachusetts requires
must be replaced prior to operating the appliance. that a flexible appliance connector cannot exceed 3ft
(914.4mm) in length.
General Information The installation must conform with local codes or, in the
This furnace is design certified in accordance with American absence of local codes, with the National Fuel Gas Code
National Standard/CSA Standard Z21.86 and CSA 2.32 by ANSI Z223.1/NFPA 54* Natural Gas and Propane Installa-
Underwriters Laboratory as a direct vent wall furnace to be tion Code, CSA B149.1.
installed according to these instructions. *Available from the American National Standards Institute, Inc., 11 West
42nd St., New York, N.Y. 10036.
Any alteration of the original design, installed other
than as shown in these instructions or use with a type • The vent terminal for HWDV081 models shall be lo-
of gas not shown on the rating plate is the responsibil- cated at least 6in (150mm) from any air opening into a
ity of the person and company making the change. building.
Notice: During initial firing of this unit, its paint will bake • The vent terminal for HWDV150 models shall be locat-
out and smoke will occur. To prevent triggering of smoke ed at least 9in (228.6mm) from any air opening into a
alarms, ventilate the room in which the unit is installed. building.
Installation in Residential Garages • The bottom of the vent terminal on all models shall be
Gas utilization equipment in residential garages shall be in- located at least 12in (304.8mm) above grade. See ter-
stalled so that all burners and burner ignition devices are mination clearance chart on page 14.
located not less than 18in (457.2mm) above the floor. Such
equipment shall be located, or protected, so it is not subject WARNING: The nearest point of the vent cap
to physical damage by a moving vehicle. should be a minimum horizontal distance of 6ft
(1.83m) from any pressure regulator. In case of regu-
lator malfunction, the 6ft (1.83m) distance will reduce
the chance of gas entering the vent cap.
Figure 1
Page 12 33444-0-0414
REQUIREMENTS FOR MASSACHUSETTS
For all side wall horizontally vented gas fueled equipment 3. SIGNAGE. A metal or plastic identification plate shall
installed in every dwelling, building or structure used in be permanently mounted to the exterior of the building
whole or in part for residential purposes, including those at a minimum height of eight feet above grade directly
owned or operated by the Commonwealth and where the in line with the exhaust vent terminal for the horizontally
side wall exhaust vent termination is less than seven feet vented gas fueled heating appliance or equipment. The
above finished grade in the area of the venting, including but sign shall read, in print size no less than one-half (1/2)
not limited to decks and porches, the following requirements inch in size, “GAS VENT DIRECTLY BELOW. KEEP
shall be satisfied: CLEAR OF ALL OBSTRUCTIONS”.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. 4. INSPECTION. The state or local gas inspector of the
At the time of installation of the side wall horizontal vented side wall horizontally vented gas fueled equipment shall
gas fueled equipment, the installing plumber or gasfitter not approve the installation unless, upon inspection, the
shall observe that a hard wired carbon monoxide detec- inspector observes carbon monoxide detectors and sig-
tor with an alarm and battery back-up is installed on the nage installed in accordance with the provisions of 248
floor level where the gas equipment is to be installed. In CMR 5.08(2)(a) 1 through 4.
addition, the installing plumber or gasfitter shall observe (b) EXEMPTIONS: The following equipment is exempt
that a battery operated or hard wired carbon monoxide from 248 CMR 5.08(2)(a)1 through 4:
detector with an alarm is installed on each additional 1. The equipment listed in Chapter 10 entitled
level of the dwelling, building or structure served by the “Equipment Not Required To Be Vented” in the
side wall horizontal vented gas fueled equipment. It shall most current edition of NFPA 54 as adopted by
be the responsibility of the property owner to secure the the Board; and
services of qualified licensed professionals for the instal- 2. Product Approved side wall horizontally vented
lation of hard wired carbon monoxide detectors. gas fueled equipment installed in a room or
(a) In the event that the side wall horizontally vented gas structure separate from the dwelling, building or
fueled equipment is installed in a crawl space or an structure used in whole or in part for residential
attic, the hard wired carbon monoxide detector with purposes.
alarm and battery back-up may be installed on the (c) MANUFACTURER REQUIREMENTS - GAS EQUIP-
next adjacent floor level. MENT VENTING SYSTEM PROVIDED. When the
(b) In the event that the requirements of this subdivision manufacturer of Product Approved side wall hori-
can not be met at the time of completion of instal- zontally vented gas equipment provides a venting
lation, the owner shall have a period of thirty days system design or venting system components with
to comply with the above requirements; provided, the equipment, the instructions provided by the
however, that during said thirty day period, a battery manufacturer for installation of the equipment and
operated carbon monoxide detector with an alarm the venting system shall include:
shall be installed. 1. Detailed instructions for the installation of the
venting system design or the venting system
2. APPROVED CARBON MONOXIDE DETECTORS. Each components; and
carbon monoxide detector as required in accordance with 2. A complete parts list for the venting system design
the above provisions shall comply with NFPA 720 and or venting system.
be ANSI/UL 2034 listed and IAS certified. (e) A copy of all installation instructions for all Product
Approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists for
venting instructions, and/or all venting design instruc-
tions shall remain with the appliance or equipment
at the completion of the installation.
33444-0-0414 Page 13
TERMINATION CLEARANCES
Page 14 33444-0-0414
GAS SUPPLY
Locating Gas Supply Never use an exposed flame to check for leaks. Appliance
The gas line can enter the unit either through the floor or must be disconnected from piping at inlet of control valve and
outside wall. The gas line opening should be made at this time. pipe capped or plugged for pressure test. Never pressure test
Location of the opening will be determined by the position of with appliance connected; control valve will sustain damage!
floor joists and the valve and union used for servicing. A gas valve and ground joint union should be installed in the
Recommended Gas Pipe Diameter
gas line upstream of the gas control to aid in servicing. It is
required by the National Fuel Gas Code that a drip leg be
Schedule 40 Pipe Tubing, Type L
installed near the gas inlet. See Figure 2. This should consist
Pipe Length Inside Diameter Outside Diameter
of a vertical length of pipe tee connected into the gas line that
Nat. L.P. Nat. L.P. is capped on the bottom in which condensation and foreign
0-10 feet 1/2in 3/8in 1/2in 3/8in particles may collect.
0-3 meters 12.7 mm 9.5mm 12.7 mm 9.5 mm
10-40 feet 1/2in 1/2in 5/8in 1/2in
4-12 meters 12.7 mm 12.7mm 15.9 mm 12.7 mm
40-100 feet 1/2in 1/2in 3/4in 1/2in
13-30 meters 12.7 mm 12.7mm 19 mm 12.7 mm
100-150 feet 3/4in 1/2in 7/8in 3/4in
31-46 meters 19 mm 12.7 mm 22.2 mm 19 mm
Note: Never use plastic pipe. Check to confirm whether your
local codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes,
it is always best to consult your local authority and installation
code.
The use of the following gas connectors is recommended:
— ANSI Z21.24 Appliance Connectors of Corrugated Metal
Tubing and Fittings Figure 2
— ANSI Z21.45 Assembled Flexible Appliance Connectors
of Other Than All-Metal Construction Method of Installing a Tee Fitting Sediment Trap
The above connectors may be used if acceptable by the
authority having jurisdiction. The state of Massachusetts
requires that a flexible appliance connector cannot exceed
3ft (914.4mm) in length.
Consult the current National Fuel Gas Code, ANSI Z223.1
CAN/CGA-B149 (.1 or .2) installation code.
Installing a Shut Off Valve
Each appliance should have its own shut off valve.
A shut off valve should be located in the vicinity of the
unit. Where none exists, or where its size or location is not
adequate, contact your local authorized installer for installation
or relocation.
Compounds used on threaded joints of gas piping shall be
resistant to the action of liquefied petroleum gases. The gas
lines must be checked for leaks by the installer. This should
be done with a soap solution watching for bubbles on all
exposed connections, and if unexposed, a pressure test
should be made.
CAUTION: Since some leak test solutions, including Figure 3
soapy water, may cause corrosion or stress cracking,
all tested pipes and joints shall be rinsed in water, un-
less it has been determined that the test solution is a
non-corrosive type.
33444-0-0414 Page 15
GAS SUPPLY (continued)
Pressure Testing of the Gas Supply System Checking Manifold Pressure
1. To check the inlet pressure to the gas valve, a 1/8in Both Propane and Natural have a pressure regulator attached to
(3.2mm) N.P.T. plugged tapping, accessible for test gauge the gas valve. Natural gas models will have a manifold pressure
connection, must be placed immediately upstream of the of approximately 4.0in w.c. (.996 kPa) at the valve outlet with
gas supply connection to the appliance. the inlet pressure to the valve from a minimum of 5.0in w.c.
2. The appliance and its individual shutoff valve must be (1.245 kPa) for the purpose of input adjustment to a maximum of
disconnected from the gas supply piping system during 10.5in w.c. (2.61 kPa). Propane gas models will have a manifold
any pressure testing of that system at test pressures in pressure approximately 10.0in w.c. (2.49 kPa) at the valve
excess of 1/2 psig (3.5 kPa). outlet with the inlet pressure to the valve from a minimum of
3. The appliance must be isolated from the gas supply piping 11.0in w.c. (2.739 kPa) for the purpose of input adjustment
system by closing its individual shutoff valve during any to a maximum of 13.0in w.c. (3.237 kPa).
pressure testing of the gas supply piping system at test A 1/8in (3.2mm) N.P.T. plugged tapping, accessible for test
pressures equal to or less than 1/2 psig (3.5 kPa). gauge connection, is located on the side of the gas pressure
WARNING: If one of the above procedures results in regulator.
pressures in excess of 1/2 psig (14in w.c.) (3.5 kPa) on the
appliance gas valve, it will result in a hazardous condition.
CLEARANCES
1. In selecting a location for installation, it is necessary to
provide adequate accessibility clearances for servicing
and proper installation.
2. Unit is supported by a wall bracket secured to the wall.
3. The minimum clearances from casing to combustible
construction is 36in (914.4mm) on top, 6in (152.4mm)
on each side and 4in (101.6mm) from the floor or from
the top surface of carpeting, tile or other floor covering
and 0in (0mm) to rear wall.
4. The minimum distance from the center of the vent cap
to the nearest outside corner or obstruction is 24in
(609.6mm).
5. The minimum wall depth is 4-1/2in (114.3mm) and the
maximum is 12in (304.8mm). The use of tubes not
supplied by the manufacturer results in unsatisfactory
performance.
Page 16 33444-0-0414
INSTALLATION LOCATION
Location - All Models For large homes or spread-out floor plans, two or more
Select a location near the center of the space to be heated. furnaces are recommended.
The heat will circulate through doorways into adjacent rooms. Do not locate furnace where a door could block the heated
Install the furnace on an outside wall. Locate wall studs so air flow. See Figure 5.
that wall opening will be located between wall studs. One Do not install in a closet, alcove or small hallway where the
wall stud can be used for attachment of inside wall plate. The furnace could be isolated by closing doors to the heated
wall opening required as shown in Figure 4 is a minimum space. See Figures 6 and 7.
diameter of 6-1/4in (158.8mm). The wall mounting plate will
Do not block air circulation of furnace.
cover a maximum wall opening of 7in (177.8mm) diameter.
A template is provided in furnace carton for positioning furnace When location is selected, check the walls to make sure there
on the wall. Also, refer to Figure 4 for positioning the furnace are no obstructions such as pipes, electric wiring, etc., which
on wall and for locating gas line connection. would interfere with the installation of the furnace or vent pipe.
Figure 4
WARNING: Provide adequate clearances and accessibility for purposes of servicing and
proper operation.
A manufactured home (USA only) installation must conform with the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI
Z225.1.
WARNING: Due to high surface temperature, keep children, clothing, and furniture away. Keep burner and control com-
partments clean.
INSTALLATION OVERVIEW
WARNING: Improper installation, adjustments, alteration, service, or maintenance can cause property damage,
personal injury or loss of life.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
These wall furnace models are designed for direct venting through a wall. Only venting components approved for these
furnaces may be used.
This unit is to be installed on a wall from 4-1/2in to 12in (114.3mm to 304.8mm) thick.
Note: All references must be considered as if the observer is standing in front of the wall and/or appliance.
Page 18 33444-0-0414
INSTALLATION OVERVIEW
2 SILICON-BASED
SEALANT
MOUNTING
PLATE
CAP
FLUE OUTLET
TUBE
AIR INLET
TUBE
WARNING: Read the installation instructions thoroughly before cutting or drilling any holes
for installation.
33444-0-0414 Page 19
INTERIOR INSTALLATION
Housewarmer recommends the use of the wall template to properly cut the wall holes and place the heater. If
1 the template is damaged or not included, refer to the table and graphic below for proper alignment of the wall
openings and heater. Be sure the baseboard does not get in the way.
A B
MEASUREMENTS
Index HWDV081(B) HWDV150(B)
A 7-3/8in (187.3mm) 11-3/8in (288.9mm)
B 10-7/8in (276.2mm) 10-7/8in (276.2mm)
C 21in (533.4mm) min 24-5/8in (625.5mm) min
D 9-1/8in (231.8mm) 9-1/8in (231.8mm)
D
E* 4in (101.6mm) min 4in (101.6mm) min
C F 6-1/4in (158.8mm) min 6-1/4in (158.8mm) min
7in (177.8mm) max 7in (177.8mm) max
*For residential garage installations, add 4-1/2in
(114.3mm).
E FLOOR LINE
GAS INLET
Trace the template wall opening and (if applicable) the gas inlet hole onto the wall. Mark the six wall mounting
3 plate screw holes onto the wall. The size of the gas inlet hole will depend upon the size of gas pipe coming into
the unit. (See this page, box 1 and page 21, box 4).
Page 20 33444-0-0414
INTERIOR INSTALLATION
Remove the template from the wall after the wall open-
ings are marked. The wall opening location markings
should be present on the wall. Ensure the wall studs
do not interfere with the wall opening.
5
Pilot
Hole
Drill a pilot hole inside of the traced circle so that a saw can
be used to cut the wall openings out.
Use a saw to cut the wall openings out of the wall and
discard the inner circle debris. Add a horizontal cross brace
above the wall opening between the wall studs to prevent
insulation from contacting the vent tube. The wall is now
prepared for the installation of the unit.
33444-0-0414 Page 21
INTERIOR INSTALLATION
7 Before installing unit, remove wall mounting plate from back of unit.
Locate the studs in the wall and use at least four wood
screws to attach the wall mounting plate to the wall.
If installing onto drywall (not into a stud), anchors must be
used.
The optional thermostat provided with this appliance is specially designed for use on millivolt systems. They
10 should never be used on 120V or 24VAC circuits.
Exterior Wall - The thermostat may be mounted on an exterior wall above the heater if it is located in the same
stud space as the vent tubes and is a minimum of 6in (152mm) above the heater.
Interior Wall - The thermostat should be installed on an inside wall away from the unit but in the same room.
Wire Gauges - It is important to use wire of a gauge proper for the length of the wire:
Page 22 33444-0-0414
INTERIOR INSTALLATION
11
12
13
Split the thermostat wire at the top and thread the ends
through the rear of the optional thermostat to the front. Se-
cure the ends of the thermostat wire to the two terminals
as shown.
14
33444-0-0414 Page 23
INTERIOR INSTALLATION
15
Line up the two tabs on the top of the wall mounting plate
with the slots in the back of the unit. Slide the back of the
unit onto the tabs of the wall mounting plate.
16
Secure the back of the unit into place using two screws
removed in step 8.
Page 24 33444-0-0414
INTERIOR INSTALLATION
After the back of the unit is attached to the wall, bring in
17 the gas line as shown on page 15, or follow the installation
GAS LINE template indications. Following your city, local and state
codes, attach the gas line to the unit.
NOTE: The gas line can come through the wall or floor of
the house.
18
19
20 Place one nylon washer on each peg of the casing door. Replace casing door.
33444-0-0414 Page 25
CUTTING THE VENT TUBES
NOTE: Flue outlet tube and air inlet tube should be measured and cut to the proper length from the back of the unit to the outside wall of
the house. See page 27, boxes 3 and 4.
FLUE OUTLET TUBE
1
AIR INLET TUBE
MOUNTING PLATE
CAP
Page 26 33444-0-0414
CUTTING THE VENT TUBES
With the furnace installed on wall the 5in (127mm) diameter air inlet tube and 3in (76.2mm) diameter flue outlet tube are
to be marked and cut using the following procedure. After cutting the tubes, each tube should be individually checked for
proper length before installing by fitting in place.
MARKER
COLLAR ON HEATER
Attach 5in (127mm) diameter air inlet tube onto the collar of
the heater. Be sure 5in (127mm) diameter air inlet tube is
placed as far as possible onto the collar of the heater. Mark
the 5in (127mm) diameter air inlet tube 1-7/16in (36.5mm)
beyond the mounting surface for the outside wall plate.
Remove 5in (127mm) diameter air inlet tube from collar of
the heater.
MARKER
COLLAR ON HEATER
33444-0-0414 Page 27
EXTERIOR INSTALLATION OF THE VENTING
NOTE: Flue outlet tube and air inlet tube should be measured and cut to the proper length from the back of the unit to the
outside wall of the house. There should be little to no venting showing on the outside of the house.
Attach 5in (127mm) diameter air inlet tube onto the collar of
the heater. Attach caulked, outside wall mounting plate into
the 5in (127mm) diameter air inlet tube.
(4) #10 x 2 ½”
3 SCREWS
Page 28 33444-0-0414
EXTERIOR INSTALLATION OF THE VENTING
MARKER
COLLAR ON HEATER
33444-0-0414 Page 29
EXTERIOR INSTALLATION OF THE VENTING
Attach vent cap into the 3in (76.2 mm) diameter flue outlet
tube. Attach vent cap to outside wall mounting plate with
three #10 x 1/2in screws provided.
Page 30 33444-0-0414
REASSEMBLY AND RESEALING VENTING SYSTEM
When vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and
resealing of the vent-air intake assembly.
Remove old furnace cement from vent cap collar and flue
outlet tube.
Remove old caulk from the outside wall mounting plate. Apply
new caulk beneath the edge of the outside wall mounting
plate. Use additional caulk to correct uneven wall surface,
such as clapboard.
(4) #10 x 2 ½”
3 SCREWS
Attach 5in (127mm) diameter air inlet tube onto the collar
of the heater. Attach caulked, outside wall mounting plate
into the 5in (127mm) diameter air inlet tube. Position the
outside wall mounting plate so that 5in (127mm) diameter
air inlet tube has a slight downward slope to the outside.
The downward slope is necessary to prevent the entry of
rainwater. Attach outside wall mounting plate to exterior wall
with four #10 x 2-1/2in screws previously removed.
33444-0-0414 Page 31
REASSEMBLY AND RESEALING VENTING SYSTEM
Attach 3in (76.2mm) diameter flue outlet tube onto flue outlet
collar on heater.
Page 32 33444-0-0414
REASSEMBLY AND RESEALING VENTING SYSTEM
Attach vent cap onto the 3in (76.2mm) diameter flue outlet
tube. Attach vent cap to outside wall mounting plate with
three previously removed screws.
33444-0-0414 Page 33
INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB
Page 34 33444-0-0414
INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB
Insert the blower behind the pilot tube and into the heater
casing.
33444-0-0414 Page 35
INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB
Route the power cords through the smaller hole in the bottom
of the heater casing as shown.
Slide fan control into the tabs on the right side of the chamber
support.
Page 36 33444-0-0414
INSTALLATION OF OPTIONAL BLOWER KIT HW125SCB
CAREFULLY BEND
10
11
12
Plug power cord into wall receptacle and reattach front panel
of heater to complete installation. Verify that the plastic
washers are still in place on the front panel when replacing it.
33444-0-0414 Page 37
BEFORE OPERATING APPLIANCE
WARNING
Improper installation, adjustments, alterations, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
conducted by a Qualified Service Person.
Under no circumstances should this heater be modified.
In case of gas leaks, turn gas valve off and call your Quali-
fied Service Person.
ATTENTION INSTALLER:
The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve during any pres-
sure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
Page 38 33444-0-0414
OPERATING INSTRUCTIONS
33444-0-0414 Page 39
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on page 39. 7. Remove the pilot access cover located on the combus-
2. Set the thermostat to lowest setting (if applicable). tion chamber.
3. Turn off all electric power to the appliance (if applicable). 8. Find pilot - follow metal tube from gas control. The
4. Open control access panel (front panel). pilot is behind the pilot access cover.
9. Turn knob on gas control counterclockwise
5. Push in gas control knob slightly and turn clockwise
to OFF. to "PILOT."
10. Push in control knob all the way and hold in. Imme-
diately light the pilot with the Piezo Pilot Ignitor or a
match. Continue to hold the control knob in for about
one minute after the pilot is lit. Release knob, and
it will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 10.
• If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob to "OFF" and call
your service technician or gas supplier.
NOTE: Knob cannot be turned from "PILOT" to "OFF" 11. Replace pilot access cover.
unless knob is pushed in slightly. Do 12. CAUTION: Pilot access cover must be kept tightly
not force. PILOT THERMOPILE closed during operation.
6. Wait ten minutes to clear out any gas.
BURNER
13. Turn gas control knob counterclockwise to
Then smell for gas, including near the "ON."
floor. If you smell gas, STOP! Follow "B" in the safety
14. Replace control access panel (front panel).
information on page 39. If you don't smell gas, go to
the next step. 15. Turn on all electric power to the appliance (if appli-
cable).
16. Set thermostat to desired setting (if applicable).
Page 40 33444-0-0414
PILOT FLAME CHARACTERISTICS
1
On the main burner, the burning gas forms a primary flame
and a secondary flame. The primary flame is blue and about
3/16in (4.8mm) high. The secondary flame is very pale blue,
3in (76.2mm) to 5in (127mm) high. Dust in the combustion
air will produce an orange flame. Do not mistake it for an
improper yellow flame.
33444-0-0414 Page 41
MAINTENANCE INSTRUCTIONS
Installation, repair and maintenance should be done by a Cleaning The Pilot Burner
QUALIFIED SERVICE PERSON. Cleaning of the pilot may be an annual necessity due to spiders.
After removing the supply tubing and orifice, use a pipe cleaner or
Steps in Removing Main Burner, Orifice and Valve wire to clean the entire internal part of the pilot.
1. Disconnect the thermopile and pilot supply line at the pilot Cleaning the Combustion Chamber and Main Burner
burner. When the main burner and vent cap are removed, all internal areas of
2. Remove the burner compartment cover 5/16in (7.9mm) socket the combustion chamber are accessible for cleaning with a vacuum
suggested. hose. The main burner may be cleaned by forcing water into the
3. Remove screw holding left side of burner and lift out. ports and the throat of the burner. The burner should be blown dry
4. Main burner orifice is now accessible. Use 1/2in (12.7mm) box or heated to dry all water out before reinstalling.
end wrench to remove and apply non-hardening pipe dope
sparingly to orifice threads when replaced.
5. To remove the entire gas valve the nut holding the orifice fitting System Check
to the chamber must be removed and the gas supply to the A millivolt meter is required to check the system. The millivolt read-
valve disconnected. After this, the valve and orifice elbow can ings should be:
be removed as a unit. • Across the thermopile terminals, 400-450 millivolts with ther-
mostat OFF.
• Across the thermopile terminals, 150-250 millivolts with ther-
mostat ON.
• Across the thermostat wires at the valve, less than 30 millivolts
with thermostat ON.
• Across the thermostat wires at the thermostat, less than 5 mil-
livolts with thermostat ON. (Strong winds, dirty pilot and low
pressure will reduce readings.)
TROUBLESHOOTING
1. Lit match goes out as it enters lighter port. 5. Thermostat does not turn the main burner on.
a. Certain wind conditions will blow out match. Ignite a. Check wiring.
match, and as it flares, thrust match through opening. b. Check all millivolt readings.
b. Open nearby door or window and relight pilot. c. Check for spider in main burner orifice.
2. Pilot flames but goes out when knob is released. 6. Yellow main burner flame soot on the vent cap.
a. See Lighting Instructions. Relight Pilot. a. Remove main burner to check for obstructions in throat,
b. Relight the pilot and hold knob down longer and harder. ports and orifices.
Close lighter hole cover just after igniting. Check for a b. Install new main burner orifice and pilot orifice. Refer to
good pilot flame. Parts List.
c. Defective thermopile or defective magnet in safety section
of valve. Replace.
3. Yellow pilot flame.
a. Obstruction at pilot orifice.
b. Clean and properly size orifice.
4. Pilot and main burner go out during normal operation.
a. Check millivolts.
b. Check for proper size of pilot flame.
c. Check for defective or weak thermopile.
d. Check input, reduce as needed.
e. Cover on pilot lighter hole must be air tight.
f. Check for tight fit of air and flue tubes at both ends of vent
assembly. No obstruction around vent that would prevent
the wind from hitting all of the vent equally.
Page 42 33444-0-0414
HOW TO ORDER REPAIR PARTS
To order parts, please visit our web site at www.housewarmerproducts.com or call 877-459-1583.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name
plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from
the following appropriate illustration and list. Be sure to give all this information.
Furnace Model Number Part Description
Furnace Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware
store.
Shipments contingent upon strikes, fires and all causes beyond our control.
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62222-0529
33444-0-0414 Page 43
PARTS VIEW
Page 44 33444-0-0414
PARTS LIST
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
33444-0-0414 Page 45
WARRANTY INFORMATION
Empire Comfort Systems Inc. warranties this space heating product to be free from defects
at the time of purchase and for the periods specified below. Space heating products must be
PLACE OWNER’S IDENTIFICATION LABEL
installed by a qualified technician and must be maintained and operated safely, in accordance
HERE
with the instructions in the owner’s manual. This warranty applies to the original purchaser
only and is not transferable. All warranty repairs must be accomplished by a qualified gas COLOQUE AQUÍ LA ETIQUETA DE IDENTI-
appliance technician. FICACIÓN DEL PROPIETARIO
Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts
Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from the date
of purchase, Empire will repair or replace at Empire’s option.
Page 46 33444-0-0414
APPLIANCE SERVICE HISTORY
Date Dealer Name Service Technician Name Service Performed/Notes
33444-0-0414 Page 47