Академический Документы
Профессиональный Документы
Культура Документы
1 of 16
Type 7 Encoder
Installation and Operation
Instructions
FCC Warning: The users of this equipment shall not change or modify the equipment in any way, or they could void their authority
to operate the equipment under FCC rules.
All information contained herein, including but not limited to product pricing and other intellectual property, is confidential and
intended for the sole use of the addressee(s) so named. Any misuse of this confidential information contained herein may result in
legal action by Computerized Security Systems dba SAFLOK and its parent company.
Table of Contents
1. Connect the power cable to the encoder (located on the back of the unit, as shown in Fig. 1). Use a
SAFLOK 12V DC power supply, part number 73763.
2. Connect the communication cable to the appropriate communication port on the back of the encoder
Ethernet network (TCP/IP), DeskLinc serial port (RS232), or PC (USB).
Fig. 1
Note: the System 6000™ software must be Version 3.08 or higher when using the Type 7 Encoder with
RFID.
7. Click OK.
RS232
Connection
Fig. 2
2. Plug the power supplies for the hand-held terminal and encoder into a wall socket.
3. Once the terminal's batteries tab have been removed and the power supplies for the hand-held
terminal and encoder are connect to a wall socket, it will display the “Power Up” menu screen.
DCA5 POWER UP ME
MENU
NU
1.Start Program
2.Terminal Settings
3.Display Version
4.Load/UnLoad Files
4. To start the program, simply press ENTER. The terminal should begin communicating with the
encoder right away. If the terminal is communicating, the encoder’s blue RS232 Link (LNK) light will
be on solid. If this does not occur, reference your DeskLinc manual for troubleshooting. The terminal
will display the Password or Sign On screen.
Note: the System 6000™ software must be Version 3.08 or higher when using the Type 7 Encoder with
RFID.
Note: The encoder can be added from only the CRS on the
computer that the encoder is attached to because the encoder is
directly connected to that computer.
4. Once connected to the PC and powered up, the PC will then search for a serial to USB driver in order
to assign it a Communication port in the Hardware manager. If a driver has not previously been
installed on the PC the encoder is being set up on, the Hardware Wizard screen will appear. Point the
Hardware Wizard to the drivers either on the SAFLOK CD or copy the USB drivers from the CD and
place them locally on the PC, then navigate the Hardware Wizard to the directory where the drivers
have been copied to.
7. At the Client Station Add-Mode PC dialog box, click Test For Encoder.
Insert the keycard with the arrow pointing down and the magstripe
facing the front of the encoder.
Inset the keycard with arrow pointing down and the chip facing the back of the encoder. When the green
lights flash around the keycard insertions slot, remove the keycard.
• If properly encoded, the green OK light will flash, indicating readiness to encode another key.
• If not properly encoded, the red ERROR light will illuminate and the computer screen will display
an error message. Follow the screen prompts and attempt to encode the keycard again.
If not properly encoded, the red ERROR light will illuminate and the computer
screen will display an error message. Follow the screen prompts and attempt
to encode the credential again.
RFID Encoder
To maintain the encoder and ensure proper operation, SAFLOK recommends cleaning the unit on a
weekly basis. Use only approved SAFLOK pre-packaged cleaning keycards.
Follow the steps to make a magstripe key and insert the pre-moistened keycard into the encoder when
prompted. Repeat several times.
To clear a jammed keycard, turn the encoder upside-down and use a thin object to press the motor run
switch on the underside of the unit.