• 500 Hp motor-compressor
• Machine vibration is known to
be very load sensitive.

• Vibration increase with high


load.
• Vibration has a strong daily
cycle.

$XWKRUJohn Schultz 'DWHDecember 22, 1997


&RPSDQ\IVC 3ODQWPharmaceutical Plant (anonymity requested)
0RWRU67$786
3DJHRI
&DVH1XPEHU

&DVH+LVWRU\
Daily ambient temperature swings
from 90C at night to over 400C
during the day.

• 2xline shows a strong reverse


relationship with ambient
temperature.
• Low ambient occurs with high
2xline.
• 2xline usually caused by rotor
eccentricity or soft foot.

&RQFOXVLRQV 5HFRPPHQGDWLRQV

• Plant found a soft foot condition which allowed vibration to increase with load.

• Data after correction is not shown.


• 2xline frequency energy is no longer significant component of data.
• Since the soft foot correction, no failure (4 months) versus previous MTBF (2 months).

$XWKRUJohn Schultz 'DWHDecember 22, 1997