CLIENT :
PROJECT :
GRADE :
1. 0 PURPOSE:
To detect lamination / inclusions type discontinuities and to evaluate them as per API 5L 44 th Edition,
BS 5996 & GAIL/MECON specification no. MEC/TS/05/21/012C.
2.0 SCOPE:
Applicable for sizing of indications found in Coil UT Testing. This procedure shall be used to detect
lamination present at pipe ends or prior to angle beam inspection of plate by contact manual UT.
4.0 RESPONSIBILITY:
Personnel performing Ultrasonic Examination shall be responsible for interpretation & evaluation of
indications during the examination & preparation of examination reports.
5.1 NDT L-I personnel may set up the equipment, shall perform tests and record the results.
5.2 NDT L-II personnel shall supervise Level-I inspector and evaluate, report the results. When required, he
shall carry out test by himself.
The Manual Ultrasonic Examination shall be carried after forming the pipe, whenever required.
8.0 TECHNIQUE:
The surface shall be free from dirt, loose scale, rust, spatter and other foreign matters which may
interfere with testing process.
11.0 COUPLANT:
The vertical and horizontal linearity of the machine is checked once in three months and the details of
the calibration data shall be recorded.
Flat bottom hole of 6.35mm dia. (as per attached sketch) in the same material having same thickness.
15.2 Adjust indication from FBH to 80%. Note down reference dB.
Instrument calibration shall be done at the beginning and to be checked in the middle & at the end of
each shift.
Scanning shall be done by moving the bigger search unit (25mm dia.) in swiveling motion on scanning
surface with 10 % overlap.
18.1 Any indication observed during scanning with 25mm dia probe whose strength is exceeding 80%FSH at
reference dB shall be investigated in terms of depth and size by a smaller 10 mm dia. probe.
When inspecting indications marked by coil UT machine acceptance criteria shall be as follows:
A. EDGES:
(1) No individual imperfection of length less than 20mm shall be considered for population density
assessment
(2) Maximum length of imperfection in any direction shall not exceed 30 mm.
(3) Maximum area of imperfection shall not exceed 500 mm2
(4) Maximum population density shall not exceed 4.
B. PLATE BODY:
20.0 DOCUMENTATION:
ANNEXURE – I