TK-5329 Floor Hardener and Densifier

Meets Federal EPA ’s VOC Requirements

PRODUCTS
Division of Sierra Corporation Technical Data
ISO 9001:2008 Certified

1. PRODUCT NAME: increase in epoxy adhesion. No change APPLICATION:


TK-5329 FLOOR HARDENER for polyurethane adhesion. TK-5329 FLOOR HARDENER &
AND DENSIFIER - ASTM C-39: 42% increase in DENSIFIER may be applied with sprayer,
compressive strength at 7 days. 39% roller, or brush.
TK-5329 FLOOR HARDENER AND DENSIFIER

2. MANUFACTURER increase at 28 days over untreated


TK PRODUCTS samples. New Concrete: Concrete must cure
DIVISION OF SIERRA CORPORATION - ASTM G-23: No effect by ultra violet a minimum of 7 days before applying TK-
11400 West 47th Street light or water spray exposure. 5329 FLOOR HARDENER & DENSIFIER.
Concrete Chemical Floor Hardener

Minnetonka,MN 55343 Water curing or covering the concrete


952-938-7223 CURING: with poly are recommended methods of
952-938-8084 (FAX) TK-5329 provides greater moisture curing. TK-2519 DC WB DISSIPATING
E-mail: tksales@tkproduct.com retention during the initial 24 hour curing CONCRETE CURE may be used to cure
Website: http://www.tkproduct.com period versus untreated samples. the concrete, but application instructions
must be precisely followed to ensure

3
PRODUCTS
3. PRODUCT DESCRIPTION: PERMEABILITY: complete removal of the curing resin.
TK-5329 FLOOR HARDENER & TK-5329 is breathable, and will allow Work TK-5329 FLOOR HARDENER &
DENSIFIER is a colorless, odorless moisture vapor to pass through the treated DENSIFIER into the surface using a soft
blend of 100% active sodium silicate surface. bristle brush or scrub pad. A mechanical
and siliconate chemicals to strengthen, scrubber must be used to increase the
harden, densify and dustproof concrete - A.I.M.Category: Sealer effectiveness of this product. Work TK-
and masonry floors. TK-5329 FLOOR - A.I.M.Definition: A coating that is 5329 into the surface until it begins to gel
HARDENER & DENSIFIER penetrates formulated and recommended for or become slippery, then rewet the surface
into the concrete, sealing the capillaries application to a substrate for one or more and work for another 10 –15 minutes.
and pores and creating a chemical reaction of the following purposes:to prevent As the surface gels or becomes slippery
with the calcium carbonate (or free lime) in subsequent coatings from being absorbed again, squeegee any excess product away
the concrete to produce a hard, mineral film by the substrate; to prevent harm to and damp-mop the entire area, rinsing the
that is resistant to damage caused by water, subsequent coatings by materials in mop with fresh water every 100-200ft2.

Concrete Chemical Floor Hardener


TK-5329 FLOOR HARDENER AND DENSIFIER
chemicals and abrasion. TK-5329 is ideal the substrate; to block stains, odors,or In order for the proper reaction to occur,
PRODUCTS

for industrial, warehousing, manufacturing efflorescence; to seal fire, smoke or water the surface must remain saturated with TK-
and food service/processing environments. damage; or to condition chalky surfaces. 5329 FLOOR HARDENER & DENSIFIER
-V.O.C.Compliant - Maximum VOC 100 g/l for a minimum of 30 minutes. Very porous
Advantages: (0.83 lb/gallon) or open concrete surfaces may result in
3

- Allows the concrete to breathe. -USDA authorization for use in meat and faster surface drying. If this occurs, you
- Contains no solvent or fumes. poultry processing facilities. must apply additional TK-5329 and leave
- Does not leave a film-like coating. for 30 minutes.
- Can be used on new or existing concrete. 5.APPLICATION PROCEDURES AND
- Waterproofs by densifying the concrete
INSTRUCTIONS Existing Concrete: Work TK-5329
and sealing pores and capillaries.
- Compatible with floor and carpeting Before using this product, read the FLOOR HARDENER & DENSIFIER into
adhesives and most stripping paints. Material Safety Data Sheet for complete the surface using a soft bristle brush or
- Does not make the floor slippery. safety information. Material Safety Data scrub pad. A mechanical scrubber must
- Resists black tire marks. Sheets are available from TK distributors be used to increase the effectiveness
- Short downtime; floors can be put back and the TK office. of this product. Work TK-5329 into the
into service immediately after treatment. surface until it begins to gel or become
Preparation: slippery, then rewet the surface and work
4. TECHNICAL DATA: The surface must be clean and free for another 10 –15 minutes. As the surface
Nontoxic, noncombustible. Complies of dirt, oil, curing compounds or foreign gels or becomes slippery again, squeegee
with all V.O.C. Regulations. materials. Patch all cracks and remove any excess product away and damp-mop
any laitence. Any cleaners need to be the entire area, rinsing the mop with fresh
APPLICABLE STANDARDS: thoroughly rinsed off. The surface can water every 100-200ft2.
- ASTM C-42 IMPACT: increases be damp, but must not have any standing
impact resistance. water as it will dilute TK-5329 and affect its In order for the proper reaction to occur,
- ASTM C-779 ABRASION: 33% performance. the surface must remain saturated with TK-
increase in abrasion resistance. 5329 FLOOR HARDENER & DENSIFIER
- ASTM D-3359 BONDING: 16.7% for a minimum of 30 minutes. Very porous
or open concrete surfaces may result in faster 6. AVAILABILITY
surface drying. If this occurs, you must apply TK-5329 FLOOR HARDENER & FOR INDUSTRIAL USE ONLY
additional TK-5329 and leave for 30 minutes. DENSIFIER is available through TK
If the floor is to be applied with any Distributors. Contact TK Products for for the 02/13
subsequent coatings or carpet or tile nearest distributor.
adhesives, wait 30 minutes then flush with Packaged in: 55-gallon drums, 5-gallon pails
water and squeegee dry. and 1 gallon cans.

COVERAGE*: 7. CONDITIONS OF SALE/ LIMITED


SURFACE COVERAGE WARRANTY
TK Products, division of the Sierra Corporation,
Steel troweled 200 sq.ft./gallon
warrants that its products conform to the label
concrete:
descriptions, are free from manufacturing defects,
Other concrete 200-250 sq.ft./gallon and are fit for the ordinary purposes for which such
surfaces:
goods are used. Inasmuch as the use of TK Products’
* Coverage rates are dependent on the
product by others and other factors affecting
porosity, density and texture of the concrete.
product performance are beyond TK Products’
control, TK Products does not guarantee the results
MAINTENANCE:
to be obtained. There are no warranties except as
Use normal dust mopping or sweeping
stated herein, either express of implied, including
between occasional detergent and water
implied warranties of merchantability or fitness for
cleanings.
a particular purpose. SHOULD ANY TK PRODUCTS’
PRODUCT FAIL TO GIVE SATISFACTORY RESULTS,
LIMITATIONS:
TK PRODUCTS WILL REPLACE THE PRODUCT, OR
Do not apply if ambient or substrate
AT ITS OPTION, REFUND THE PURCHASE PRICE.
temperature is below 32°F. Over application
THIS IS THE SOLE AND EXCLUSIVE REMEDY FOR
may cause discoloration or a white haze to
ANY FAILURE OF TK PRODUCTS’ PRODUCTS TO
develop. Brush out all puddles to prevent
PERFORM AS WARRANTED AND SHALL ALSO
formation of white residue. Protect surrounding
CONSTITUTE LIQUIDATED DAMAGES IN CASE OF
metal, glass, wood, brick and painted surfaces.
LOSS. UNDER NO CIRCUMSTANCES SHALL THE
Protect from freezing.
BUYER BE ENTITLED TO ANY OTHER REMEDY
OR DAMAGES. REMEDIES FOR INCIDENTAL AND
PRECAUTIONS:
CONSEQUENTIAL DAMAGES ARE SPECIFICALLY
May cause nose, throat, lung eye and skin
EXCLUDED. TK Products does not authorize
irritation. Harmful if inhaled. Avoid inhalation
any person to assume for it any other liability in
of vapors and spray mist. Avoid contact with
connection with the sale or use of its products
eyes and skin. Close container when not
unless specifically authorized by TK Products in
in use. Use only with adequate ventilation.
writing.
Wash thoroughly after handling or contact.
KEEP OUT OF REACH OF CHILDREN.
8. TECHNICAL SERVICES
SPILLS OR LEAKS:
The TK office offers assistance with
If spilled, contain spilled material and remove
specifications, performance test data and field
with inert absorbent. Dispose of contaminated
services.
absorbent, container and unused contents
in accordance with local, state and federal
9. FILING SYSTEMS
regulations.
Information Handling Services
FIRST AID:
PO Box 1213
Inhalation: If you experience difficulty
Englewood, CO 80150
in breathing, leave the area to obtain fresh
Information Marketing Services
air. If continued difficulty is experienced, get
13271 Northend
medical attention immediately.
Oak Park, MI 48237
Eye Contact: In case of eye contact,
flush immediately with plenty of water for at
TK DISCLAIMER:
least 15 minutes and get medical attention
Every effort has been made to ensure the accuracy
immediately.
of the above information and to avoid infringement of
Skin Contact: Wash thoroughly with soap
any patent or copyright. The information is based on
and water.
field tests by government and private agencies, as well
Ingestion: If swallowed, induce vomiting
as lab tests, and on technical data from raw material
as directed by physician, hospital emergency
manufacturers. The person(s) specifying or requesting
room or poison center. Give conscious victim
the use of these products is responsible for assuring
1 to 2 glasses of water and get medical
their suitability for a specific use, as well as the proper
attention immediately.
application of the products. Where there is any question
as to the suitability of a particular product, a small test
24 Hour Chemical Emergency
patch is recommended. See also CONDITIONS OF
SALE/ LIMITED WARRANTY (Section 7) above.
CHEMTREC 1-800-424-9300
Replaces 10/12