Linear LED T8 Lamp

Direct Replacement LED T8


F32T8/8xx/LED/22W/IS Series

5  Year  
Warranty!  
Why Linear LED?
•  Very efficient converting electric power to light output
Energy Efficient •  Energy savings compared to T12 systems
•  Lower energy usage reduces energy costs
•  Longer rated life over incandescent, HID, and
fluorescent lighting systems
Reduced •  Longer rated life means lower maintenance costs of
Maintenance lamp change outs

•  Better environmental choice


•  High quality lighting gives design flexibility
Sustainable •  Can be used with lighting controls without
compromising lamp life
LEDT8 Features
•  Does not require electrical re-wiring to install
•  For use with Electronic Instant Start Ballasts
•  Automatically adjusts to the corresponding Ballast Factor
•  19w (Low Ballast Factor)
•  22w (Standard Ballast Factor)
•  26w (High Ballast Factor)
•  Environmentally friendly – no mercury, no UV or infrared light
•  Low lumen depreciation – maintains brightness over its 50,000 hour
rated life
•  Minimum heat emission, reducing load on building cooling systems
•  No flickers
•  ETL tested to comply with OSHA safety standards
•  DesignLights Consortium® Listed Product (4100K & 5000K lamps).
Visit designlights.org to view the Qualified Products List
....Another important consideration when replacing linear
fluorescent lamps with LED products is electrical safety.
HOWARD LEDT8 USES THE
Nearly all LED replacements bypass the existing ballast. EXISTING INSTANT START
BALLAST

HOWARD LEDT8
Most have their drive electronics integrated in the tube DOES NOT

while some are provided with external drivers that replace the existing HOWARD LEDT8
fluorescent ballast. DOES NOT

Bypassing the existing ballast results in line voltage being delivered to


HOWARD LEDT8
the sockets (“tombstones”) in the fluorescent fixture, creating a hazard if DOES NOT
a fluorescent lamp is later re-installed in that same fixture.

If a fixture is modified such that it can no longer accept its original lamp,
HOWARD LEDT8 DOES NOT,
it must have a label affixed (provided by the LED replacement NO LABEL IS NEEDED
manufacturer) clearly indicating this condition.

SOURCE DEPARTMENT OF ENERGY:


http://apps1.eere.energy.gov/buildings/publications/pdfs/ssl/led-t8-fluorescent-replacement.pdf
4’ T8 Lamp Change out with
New LED T8 Lamp
Using Normal Power Factor
Present Bulb Wattage 29.5 watts (F32T8 Lamp) Instant Start Multi-volt Ballast

LED Bulb Wattage 22 watts (using Standard Ballast Factor Ballast)


Wattage Saved 7.5 watts
LED Bulb Life 50,000 hours
Energy Saved 375,000 watts over lamp life
To convert to Kilowatt Hours Divide by 1000
Energy Saved 375 KwH
KwH Rate $0.12 $0.10 $0.08
Amount saved per lamp $45.00 $37.50 $30.00
Energy and Cost Savings
Compared to T8 System
Existing System New System

System descriptions 4 Lamp F32T8 4 Lamp LED System


(optional) Linear Fluorescent Fixture Linear Fluorescent Fixture

Hours burned
per year 4368 Number of Fixtures 1 Number of Fixtures 1
Watts per Fixture Watts per Fixture
Cost per kWh $ 0.12 (exiting system) 110 (new system) 88

Energy used per yr. Energy used per yr.


(existing system) $57.65 (new system) $46
Energy Cost Estimation
Energy savings per year
(each new system fixture) $11.65

20%
Energy Saved!
Ideal for a wide range of applications
•  Manufacturing facilities
•  Schools
•  Food Processing
•  Office Buildings
•  Dusty applications
•  Other applications
•  Re-lamping to comply with DOE energy efficiency standards
•  Hallways, Stairwells and other areas needing more directional
light and 24/7 operation
LEDT8 Series Specifications
Ballast Factor (BF)* Low (78%) Standard (88%) High (110%)

Power Consumption (P) 19 watts 22 watts 26 watts

Luminous Flux (F) 1,900 lumens 2,200 lumens 2,600 lumens

Luminous Efficacy** 100 lm/W

Input Voltage 110-277v (Instant Start Electronic Ballast only)

Power Factor 0.90

Color Temperature 80+ CRI

Color Rendering Index 3500K, 4100K, or 5000K

Rated Life 50,000 hours

* The LED26T8 Lamp “self-adjusts” light output that matches the corresponding ballast factor of the supply (or
control) ballast. The new “system matched” light output will meet or exceed that of the one it is replacing.
**Efficiency measured using 4100K with clear lens.
Ordering Information
4ft. Linear T8 LED Lamp,
799385-62007 F32T8/835/LED/22W/IS
80+CRI, 3500K
4ft. Linear T8 LED Lamp,
799385-62008 F32T8/841/LED/22W/IS*
80+CRI, 4100K
4ft. Linear T8 LED Lamp,
799385-62009 F32T8/850/LED/22W/IS*
80+CRI, 5000K