Вы находитесь на странице: 1из 42

LIST OF STANDARD DRAWING UPDATE 31 JULY 2017

Document Number Title Revision Description


TEP-900-STD-CV-BP4-0024 Abbreviation And Symbol For Civil Work B01 Issued For
Information
TEP-900-STD-ST-BP4-0008 General Notes For Structure B02 Re-Approve
For Use
TEP-900-STD-ST-BP4-0009 Standard Drawing Member Designation For B01 Issued For
Steel Structure Information
TEP-900-STD-ST-BP4-0019 Standard Welding Details B02 Re-Issued
For
Information
TEP-900-STD-CV-BP4-0033- Standard Drawing Anchor Bolts Sheet 1 B02 Re-Approve
001 For Design
TEP-900-STD-CV-BP4-0033- Standard Drawing Anchor Bolts Sheet 2 B01 Approve For
002 Design
TEP-900-STD-CV-BP4-0033- Standard Drawing Anchor Bolts Sheet 3 ~ 7 B02 Re-Approve
003~ 007 For Design
TEP-900-STD-ST-BP4-0010- Standard Drawing Column Base Plate C01 Approved
001 (Pinned) Connection For
Construction
TEP-900-STD-ST-BP4-0010- Standard Drawing Column Base Plate (Fixed) C01 Approved
002 Connection Sheet 1 For
Construction
TEP-900-STD-ST-BP4-0010- Standard Drawing Column Base Plate (Fixed) A02 Issued For
003 Connection Sheet 2 Approval
TEP-900-STD-ST-BP4-0010- Standard Drawing Column Base Plate (Fixed) A02 Issued For
004 Connection Sheet 3 Approval
TEP-900-STD-ST-BP4-0014 Standard Drawing For Column Splice and C01 Approved
Double Shear Connection (Sheet 1 ~ 3) For
Construction
TEP-900-STD-ST-BP4-0012 Standard Drawing Beam To Column Pinned B01 Approve For
Connection Use
TEP-900-STD-ST-BP4-0007- Standard Drawing Beam To Column A02 Issued For
001 Moment Connection Welded Type – Sheet 1 Approval
TEP-900-STD-ST-BP4-0007- Standard Drawing Beam To Column A01 Issued For
001 Moment Connection Welded Type – Sheet 2 Review
TEP-900-STD-ST-BP4-0011- Standard Drawing Beam To Column C01 Approved
001 Moment Connection (1) For
Construction
TEP-900-STD-ST-BP4-0011- Standard Drawing Beam To Column C01 Approved
002 Moment Connection (2) For
Construction
TEP-900-STD-ST-BP4-0013 Standard Drawing Beam To Beam Pinned C01 Approved
Connection For
Construction
TEP-900-STD-ST-BP4-0016 Standard Drawing Horizontal Bracing B02 Re-Issued
Connection For
Information
LIST OF STANDARD DRAWING UPDATE 31 JULY 2017

Document Number Title Revision Description


TEP-900-STD-ST-BP4-0015- Standard Drawing Vertical Bracing B01 Approve For
001 Connection -01 Design
TEP-900-STD-ST-BP4-0015- Standard Drawing Vertical Bracing B01 Approve For
002 Connection -02 Design
TEP-900-STD-ST-BP4-0018 Standard Drawing Post Connection To Beam C01 Approved
For
Construction
TEP-900-STD-CV-BP4-0038 Standard Drawing For Steel Flooring B01 Approve For
Use
TEP-900-STD-ST-BP4-0020 Standard Drawing Expansion Joint B01 Issued For
Information
TEP-900-DWG-CV-BP4-0012- Standard Drawing For Handrails C02 Re-
001 Approved
For
Construction
TEP-900-DWG-CV-BP4-0013- Standard Drawing For Ladder (1 Of 2) B03 Re-Issued
001 For
Information
TEP-900-DWG-CV-BP4-0013- Standard Drawing For Ladder (2 Of 2) B03 Re-Issued
002 For
Information
TEP-900-DWG-CV-BP4-0014- Standard Drawing For Stairs (1 Of 2) B03 Re-Issued
001 For
Information
TEP-900-DWG-CV-BP4-0014- Standard Drawing For Stairs (2 Of 2) B03 Re-Issued
002 For
Information
TEP-900-STD-CV-BP4-0028- Standard Drawing Fire Proofing of Structural A03 Issued For
001 Steel (Sheet-01) Approval
TEP-900-STD-CV-BP4-0028- Standard Drawing Fire Proofing of Structural A03 Issued For
002 Steel (Sheet-02) Approval
TEP-900-STD-CV-BP4-0028- Standard Drawing Fire Proofing of Structural A03 Issued For
003 Steel (Sheet-03) Approval
TEP-900-STD-ST-BP4-0017- Standard Drawing Detail Combination of B01 Issued For
001 Steel Connection (1) Information
TEP-900-STD-ST-BP4-0017- Standard Drawing Detail Combination of B01 Issued For
002 Steel Connection (2) Information
A B C D E F G H J K

1 1

2 2

3 3

4 4

5 B02 08-AUG-2017 RE-ISSUED FOR INFORMATION AGI / MMT HS / TAR MAH / CCL 5
B01 13-OCT-2016 ISSUED FOR INFORMATION HAR / SH LQ / MT MAH / CCL

REV DATE DESCRIPTION DRAWN CHKD APPD


REVISIONS

REFERENCE
DRAWINGS
TEP-900-STD-ST-BP4-0008 GENERAL NOTES FOR STRUCTURE

DWG NO. TITLE

TANGGUH EXPANSION PROJECT


6 6

STANDARD DRAWING
MEMBER DESIGNATION
FOR STEEL STRUCTURE
7 CONTRACT NO. @BP p.l.c.
SECURITY CLASSIFICATION:
DOC. CLASS SCALE
7
4420001030 3 NTS
BP INTERNAL
COMPANY DRAWING NO. X CORE SIZE REV.
TEP-900-STD-ST-BP4-0009 A1 B02
NON CORE
CONTRACTOR'S C-NUMBER CONTRACTOR'S S-NUMBER
870310-PTS-900-STR-DWG-24101

A B C D E F G H J K
A B C D E F G H J K

1 1

2 2

3 3

4 4

B02 09-AUG-2017 RE-APPROVED FOR DESIGN BND / KIS LSY / TAR MT / CCL

B01 02-MAR-2017 APPROVED FOR DESIGN MMT / KIS SLA / TAR MT / CLL

5 A02 03-FEB-2017 ISSUED FOR APPROVAL MMT / KIS SLA / TAR MT / CLL 5
A01 06-DES-2016 ISSUED FOR REVIEW HNB / KIS SLA / TAR LQ / CCL

REV DATE DESCRIPTION DRAWN CHKD APPD


REVISIONS
TEP-900-STD-ST-BP4-0017 STANDARD DRAWING DETAIL COMBINATION OF STEEL CONNECTION

TEP-900-STD-ST-BP4-0019 STANDARD WELDING DETAILS


REFERENCE
TEP-900-STD-ST-BP4-0009 STANDARD DRAWING MEMBER DESIGNATION FOR STEEL STRUCTURE
DRAWINGS
TEP-900-STD-ST-BP4-0008 GENERAL NOTES FOR STRUCTURE

DWG NO. TITLE

TANGGUH EXPANSION PROJECT


6 6

STANDARD DRAWING
VERTICAL BRACING CONNECTION

7 CONTRACT NO. @BP p.l.c.


SECURITY CLASSIFICATION:
DOC. CLASS SCALE
7
4420001030 2 NTS
BP INTERNAL
COMPANY DRAWING NO. X CORE SIZE REV.
TEP-900-STD-ST-BP4-0015-001 A1 B02
NON CORE
CONTRACTOR'S C-NUMBER CONTRACTOR'S S-NUMBER
870310-PTS-900-STR-DWG-24107.001

A B C D E F G H J K
A B C D E F G H J K

1 1

2 2

3 3

4 4

B02 09-AUG-2017 RE-APPROVED FOR DESIGN BND / KIS LSY / TAR MT / CCL

B01 02-MAR-2017 APPROVED FOR DESIGN MMT / KIS SLA / TAR MT / CCL

5 A02 03-FEB-2017 ISSUED FOR APPROVAL MMT / KIS SLA / TAR MT / CCL 5
A01 06-DES-2016 ISSUED FOR REVIEW HNB / KIS SLA / TAR LQ / CCL

REV DATE DESCRIPTION DRAWN CHKD APPD


REVISIONS
TEP-900-STD-ST-BP4-0017 STANDARD DRAWING DETAIL COMBINATION OF STEEL CONNECTION

TEP-900-STD-ST-BP4-0019 STANDARD WELDING DETAILS


REFERENCE
TEP-900-STD-ST-BP4-0009 STANDARD DRAWING MEMBER DESIGNATION FOR STEEL STRUCTURE
DRAWINGS
TEP-900-STD-ST-BP4-0008 GENERAL NOTES FOR STRUCTURE

DWG NO. TITLE

TANGGUH EXPANSION PROJECT


6 6

STANDARD DRAWING
VERTICAL BRACING CONNECTION

7 CONTRACT NO. @BP p.l.c.


SECURITY CLASSIFICATION:
DOC. CLASS SCALE
7
4420001030 2 NTS
BP INTERNAL
COMPANY DRAWING NO. X CORE SIZE REV.
TEP-900-STD-ST-BP4-0015-002 A1 B02
NON CORE
CONTRACTOR'S C-NUMBER CONTRACTOR'S S-NUMBER
870310-PTS-900-STR-DWG-24107.002

A B C D E F G H J K

Вам также может понравиться