Вы находитесь на странице: 1из 2

CURRENT CONTROL S.S.

R
KC2010AX KC4010AX
KC2015AX KC4015AX
KC2025AX KC4025AX
KC2040AX KC4040AX
KC2050AX KC4050AX
KC2075AX KC4075AX
KC2090AX KC4090AX

KC SERIES
Product Description
The analog switching relay works in accordance with the phase angle control principle, i.e. the output switching point in the AC
sine wave depends on the control current. 4mA corresponds to no switching and 20mA corresponds to full sine wave (near line-
ar power response). The relay switches off every time the output current crosses zero, and switches ON in accordance with the
applied control current

General Specifications

Current Max Load Rated Operational Non-rep. peak Insulation Voltage Insulation Voltage
Switching Mode Control Current Input-Output Output-Case
Voltage Voltage
KC2010AX 10A
KC2050AX 50A
KC2015AX 4 ~ 2 0 m A 15A
KC2025AX
KC2075AX
( DC3.8~10V ) 25A
75A 24~280VAC 600Vpeak 4000Vrms 2500Vrms
KC2090AX 90A
KC2040AX 40A
KC4010AX 10A
KC4050AX 50A
KC4015AX 4 ~ 2 0 m A 15A
KC4075AX ( DC3.8~10V ) 25A
75A 48~480VAC 1200V peak 4000Vrms 2500Vrms
KC4025AX KC4090AX 90A
KC4040AX 40A

Operational Power Operating Storage Junction


Switching Mode Weight (g) CE-marking
Frequency Range Factor Temperature Temperature Temperature
KC2010AX
KC2050AX
KC2015AX
KC2075AX 40 to 65 Hz >0.90 0 to +70c -20c to +100c 125c Approx. Yes
KC2025AX
KC2040AX
KC2090AX 100g
KC4010AX
KC4015AX
KC4050AX Approx. Yes
KC4075AX 40 to 65 Hz >0.90 0 to +70c -20c to +100c 125c
KC4025AX
KC4090AX 100g
KC4040AX

Output Specifications

Mini Operational Rep. overload Non-rep. Surge Off-state leakage I 2t for fusing Critical dl/dt Critical dV/dt
Current Current t=1s Current t=10ms Current t=1 - 10 ms @50hz off-state min.
10A 150mA 25Ap 120A p <4mA 60A2s 100A/ s 1000V/ s
15A 150mA 30Ap 168A p <4mA 180A2s 100A/ s 1000V/ s
25A 150mA 55Ap 300A p <4mA 400A2s 100A/ s 1000V/ s
40A 150mA 100Ap 420A p <4mA 1250A2s 100A/ s 1000V/ s
50A 150mA 125Ap 520A p <4mA 1300A2s 100A/ s 1000V/ s
75A 150mA 135Ap 750A p <4mA 1800A2s 100A/ s 1000V/ s
90A 150mA 150Ap 1400A p <4mA 7200A2s 100A/ s 1000V/ s

Input Specifications

Control current Response time Off-state leakage Dynamic Allowable input Reverse Polarity
Pick up Current Drop out Current
Range (Input - Output ) Current Impedance Current (max.) Protected
4~20mA 4mA 3.5mA 10ms >10VDC @20mA 150 50mA Yes
OUTLINE DIMENSIONS (unit:mm)

PANEL HEAD SCREW 2 4.5

8 28

20
OUTPUT 24~280VAC
1 ~ 2
KYOTTO R

48.5
CURRENT CONTROL S.S.R

57
KYTECH ELECTRONICS, LTD.

KCXXXXAX

21.4
4
- CONTROL 4~20mA
+3

3.51
PANEL HEAD SCREW
6.32 21.5
43+0.1 25+0.1

EQUIVALENT CIRCUIT

EMI Filter
+
+
CONTROLLER

3 2
TEMPERURE

load

FH0650B
FH0650B
Iron Porcelain Ring

Iron Porcelain Ring


FH0650B
FH0650B
Iron Porcelain Ring

Iron Porcelain Ring

DETECTOR

of the pottery

of the pottery
CONTROL
of the pottery

of the pottery

PHOTO

PHASE

CIRCUIT

IN AC OUTPUT
DIGTAL

C=1.0uF

C=0.47uF
-
- 4 1

Applications

This relay is suitable for control of heaters , lighting and slightly inductive loads such as small fans.
The relay can also be used for soft trun-on of high-power incandescent lamps.

Ii n A1
L1
U line
4

1
KYOTTO
KYTECH ELECTRONICS, LTD.
CURRENT CONTROL S.S.R

A
-

OUT
KCXXXXAX

load
OUTPUT
CONTROL 4~20mA

4 to
~
~

2 0mA
R

24~280VAC
+3

A2
2

T1

Transfer Characteristics

Output power as a function ofcontrol input ( 4 to 20mA)


I in [mA] P out [%]
4 4 Attention:
6 13
8 25 In order to be in compliance with the EMC
Directive an additional common mode choke and
10 38 X2capacitor at the output is requried if theSSR
12 50 is operated as single component. In case the
62 SSR is incorporated in an appliance the
14 existing EMI Filter may provide the required EMI
16 75 suppesion.The EMI Filter Must be placed as close as
18 87 possible to the output temminats.See also above.
20 100

Вам также может понравиться