Вы находитесь на странице: 1из 4

s

Your Local Partners

Ahmedabad Gurgaon Lucknow


Girish Cold Drink Cross Road Plot No. 78, JIL Building 28/45, Ashok Marg, Verna
Navarangpura, 3rd Floor Sector 18 Lucknow – 226001
Prerna Arbor Building, Off C G Road Gurgaon – 122015 Tel.: +91 522 403 1000
Ahmedabad – 380009 Tel.: +91 124 284 2000 Fax: +91 522 403 1019
Tel.: +91 79 4020 7600 Fax: +91 124 234 9050
Mumbai
Fax: +91 79 4020 7699
Hyderabad 130, Pandurang Budhkar Marg
Bengaluru 5-9-19, 4th & 5th Floor Worli
3rd Floor, Jyoti Mahal Laxmi Narasinh Estate Mumbai – 400018
49, St. Marks Road Hyderabad – 500004 Tel.: +91 22 3967 7000
Bengaluru – 560001 Tel.: +91 40 2348 2500 Fax: +91 22 3967 7500
Tel.: +91 80 3342 2000 Fax: +91 40 2324 3145
Nagpur
Fax: +91 80 3342 2580
Jaipur Landmark Building, 5th Floor
Bhopal 6, Park Street Ramdaspeth
207, Harikripa Complex Opp Pink City Petrol Pump Nagpur – 440010
Commerical Area M.I. Road Tel.: +91 712 309 3000
Zone II, M.P. Nagar Jaipur – 302001 Fax: +91 712 309 3111
Bhopal – 462011 Tel.: +91 141 5151 2100
Patna
Tel.: +91 755 276 1845 Fax: +91 141 5151 2121
Ashiana Tower, 3rd Floor
Fax: +91 755 400 4676
Kochi Flat No 317, Exhibition Road
Chandigarh K.G. Oxford Business Centre Patna – 800014
SCO 189 - 191, 3rd Floor, Sector 17C 39-4609, 3rd Floor – A Tel.: +91 612 6450970 / 6510295
Chandigarh – 160017 Srikandath Road, Ravipuram
Pune
Tel.: +91 172 4690 300 Kochi – 682016
Tower B / 701 - 705
Fax: +91 172 4690 399 Tel.: +91 484 402 8611/622
ICC Trade Tower
Fax: +91 484 238 0201
Chennai 403 A, Senapati Bapat Road
Seethakathi Business Centre Kolkata Pune – 411016
4th & 5th Floor 43, Shanti Palli, Rashbihari Tel.: +91 20 2570 6000
272/688, Annasalai Bypass Connector Fax: +91 20 2570 6060
Chennai – 600006 Kolkata – 700042
Tel.: +91 44 3047 4000 Tel.: +91 33 2444 9000/09
Fax: +91 44 2833 4011 Fax: +91 33 2444 9010

Multimobil 2.5
Oil & Gas
Setting Division
new standards - Mumbai,
in Mobile India
X-ray performance

www.siemens.co.in
Manufacturer: Siemens Ltd. HC-CP-XP-016
Siemens Ltd. (This replaces HC-CP-XP-005)
Healthcare
Goa Works 130, Pandurang Budhkar Marg
Healthcare Worli, Mumbai – 400018
L6, Verna Industrial Estate Tel.: 022 3967 7000
Verna, Salcete Fax: 022 3967 7500
Goa – 403722 Toll Free No.: 1800 419 7477
Tel.: 0832 3070100 E-mail: hc_contact.india@siemens.com All rights reserved. No part of this brochure may
Prudent 022015_1000

Fax: 0832 3070101 www.siemens.co.in be reproduced in any form or by any means


without the prior written permission of Siemens.

Product upgradation is a continuous process.


Hence, data in this brochure is subject to change
without prior notice. For the latest information, Answers for life.
www.siemens.co.in/healthcare please get in touch with our Sales Offices.
About Goa Works
High frequency and two pulse - comparison... The guiding spirit behind
the Goa factory is to
Efficiency of Output provide high quality
High Frequency Generator
World-class medical
Conventional Generator (2 pulse) (Approx. 14000 pulses)
equipment at an
affordable price. A wide
output voltage output voltage range of X-ray systems,
mobile units,
useful voltage radiography systems,
useful output
fluoroscopy systems are
manufactured here.

skin dose
0 time T 0 time T

The High Frequency waveform is practically constant at the peak value making output very efficient.
The skin dose is less than with a two pulse generator.

Multimobil 2.5
The factory is also certified by the Products from our Goa
Bureau of Indian Standards for
Humane Technology from Siemens call this as the useful radiation (dose). The
IS:7620 (Part 1). The radiation
Works are exported to
- High dose yield yet low patient dose lower voltages (less than 75% of the nominal
voltage value) produce soft radiation which is safety of products manufactured in 34 Countries
Siemens, one of the pioneers in mobile X-ray
imaging, through continuous research and
partly absorbed by the patient's body. This Goa is certified by the Atomic around the world
radiation is the unwanted radiation called Skin Energy Regulatory Board (AERB),
development activities, constantly rewrites the
dose.
standards with a conscious effort to evolve a Govt. of India.
humane technology. The Multimobil 2.5 with its High Frequency
Technology ensures that only a film effective AERB - 99-TA-168
What is High Frequency Technology?
dose is produced over the entire duration of L No.CM/L - 7170767
With a conventional 2-pulse X-ray generator,
the exposure while suppressing the unwanted
voltages are generated from zero to the
skin dose.
nominal voltage. But only the voltages above
approximately 75% of the nominal voltage
value contribute to the film blackening. We

2 7
Why use Customer Care Centre?
Accuracy and quality of output
8
Round-the-clock call registration and Customer complaint made to our Toll Free
handling through Toll Free Helpline Helpline 1800 419 7477 is registered at Accuracy of Output Siemens solution for your line condition blues
1800 4197 477 our Call Centre with relevant details and

Input line resistance - (Ohms)


2 pulse High Frequency
then transferred to the concerned product 1.6
8
Immediate response and Call closing
expert at our customer care centre or to 1.5
through phone support, wherever
our CSE (Customer Support Engineer) 1.4
possible 1.3
depending on the model of the product.

Tube
Control HT 1.2
They will explore the possibility of closing Trafo

Tube
8
Check on the complaint status on a Control HT Panel 1.1 Multimobil 2.5
Real-time-basis the complaint through 'phone support'. If it Panel Trafo 1.0

requires the visit of CSE to the customer 0.9

8
Reduced down time of the equipment site, the same is arranged. The CSE will 0.8

0.7
Comparable
attend to the complaint and close it to the Feedback Loop Units
8
Flexibility to choose from a range of 0.6
satisfaction of the customer.
modular service agreements (or 0.5
150 170 207 244 265
contracts). If a part is required to be replaced, the
concerned CSE will order for the same from Input line voltage (volts)
the Service Logistics team, who will
arrange for the part and send it to the CSE.
The CSE will replace the part, test the
system and hand over the machine back to
You can call our Toll Free Helpline the customer.

1800 4197 477 For the application support of a newly

080 - 66201510
or installed system / subsequent application
support, same process as above is
Salient Features
followed.
With the Multimobil 2.5, the advantages What you set is what you get - Where can you use it -
for the patient and the operator are Highest reproducibility at all times • Bedside radiography in patient wards and
obvious Yet another technological milestone in the in the operating room
• High dose yield and shorter exposure Multimobil 2.5 is the microprocessor based • As an additional stand-alone X-ray
times design with the data feedback loop. This workstation
The dose yield is over 60% more than ensures output accuracy at every point of
• Sports medicine
conventional 2-pulse generators. Which time. So the output is exactly equal to your
means, with the Multimobil 2.5, you will set parameters. • Veterinary medicine
need much lower factors than those Reproducibility of all exposure parameters
required in conventional generators to Plug Multimobil 2.5 into any grounded
by automatic calibration (self correction) wall socket, switch it on and you are
deliver the same dose. The exposure process using the feedback loop, results in
times are correspondingly reduced by ready to start the examination.
very high consistency in exposures and
upto 40% over conventional generators. image quality.
• Improved image quality
Shorter exposure times reduce kinetic Siemens solution for your line condition
blurring giving sharp radiographs. The blues -
quality of the radiograph of moving Wide operation range
organs is thus decisively improved. The Multimobil 2.5 has set a new standard
• Low skin dose among high frequency generators by
Soft radiation is suppressed to reduce performing consistently under the worst
the unwanted skin dose. possible line conditions.
• Optimum utilization of X-ray tube It can deliver the output consistently even
High frequency technology ensures when the input power supply voltage falls
longer tube life. to a value as low as 170 Volts or even
when the supply rises to a high of 265
Volts.

6 3
Versatile positioning of the tubehead showing maximum reach Control panel with digital display

Operator Friendly - Technical Data at a glance Crisp Digital read out - So why is the Multimobil 2.5 excellent
Simple to use, Easy to move View it to believe it value for your money -
Output Power 2.5kW as per IS:7620 (Part 1)
With a clear layout and good ergonomics, Simply because it offers you all of it in one
Easy to position, easy to adjust Output wave High frequency, maximum ripple 5kV
The X-ray tube angulation can be read single unit
kV range 40kV to 100kV the control panel allows you to set and
Easy adjustments of various projection on the scales on both sides of the tube view the kV and mAs values on digital • Latest technology from the pioneers
mA range 13mA to 63mA
directions with minimum efforts are head. display specially designed to aid in dark in X-rays
mAs range 0.32mAs to 200mAs
made possible by the counterbalanced room conditions. • High dose yield
A convenient and safe parking Exposure time 20 ms to 5 secs
tube support arm design. The tube head • Low patient dose
position for the tube head ensures Exposure technique Two point technique With your settings of the kV and mAs, the
is adjustable in all planes and allows both microprocessor calculates the maximum • Highest reproducibility of exposures with
safety, specially when on the move. (only kV and mAs to be adjusted)
horizontal and vertical exposures. mA and minimum time(s) to make the sharp images
Low weight and compact functional X-ray tube CEI OX 110-1 Stationary Anode X-ray tube
exposure shorter and free of artefacts. • Consistent performance even under
design give the Multimobil 2.5 Focal spot 1.5mm X 1.5mm
extreme line conditions
enhanced manoeuverability along Inherent filteration 0.5mm AI
• Wide range of radiography applications
with easy mobility. Tube head angulations Along X-ray tube axis: +1800 / -300
• Compact and functional design with
At yoke connection to arm: + 900
good ergonomics
Unit dimensions 65 x 142 x 142cm (width x height x length)
• Operator friendly, high mobility, easy to
Weight of the unit 147kgs
manoeuvre.
Installation Information
Mains voltage Single phase 190 - 240V, +10%, 50Hz,
mains resistance < 1.5ohms
Power consumption 3kVA
Mains connector 15A plug
Safety standards IS:7620 and AERB Safety Code, IEC 60601-1