Академический Документы
Профессиональный Документы
Культура Документы
Data Sheet
02 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Table of Contents
Definitions and Conditions....................................................................................................... 3
Frequency and Time Specifications......................................................................................... 4
Amplitude Accuracy and Range Specifications...................................................................... 6
Dynamic Range Specifications................................................................................................ 9
General Specifications............................................................................................................ 13
Inputs and Outputs................................................................................................................. 15
Other Optional Outputs.......................................................................................................... 17
I/Q Analyzer............................................................................................................................. 19
I/Q Analyzer - Option B40...................................................................................................... 22
I/Q Analyzer - Option H1G..................................................................................................... 26
Real-time Spectrum Analyzer (RTSA)................................................................................... 28
Related Literature................................................................................................................... 28
This data sheet is a summary of the specifications and conditions for N9041B UXA signal
analyzers.
www.keysight.com/find/uxa110
03 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
95th percentile values indicate the breadth of the population (approx. 2s) of performance
tolerances expected to be met in 95 percent of the cases with a 50 percent confidence,
for any ambient temperature in the range of 20 to 30 °C. In addition to the statistical
observations of a sample of instruments, these values include the effects of the uncer-
tainties of external calibration references. These values are not warranted. These values
are updated occasionally if a significant change in the statistically observed behavior of
production instruments is observed.
www.keysight.com/find/uxa110
04 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. The exact maximum frequency for Option 590 depends on the analysis bandwidth option chosen: Max frequency = (90 - 1/2x (analysis bandwidth in GHz))
2. Horizontal resolution is span/(sweep point-1)
3. Nominal for Input 2 above 50 GHz
www.keysight.com/find/uxa110
05 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or
processing in the time, frequency, or modulation domain.
www.keysight.com/find/uxa110
06 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
08 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. Only affects the display, not the measurement, so it causes no additional error in measurement results from trace data or markers.
www.keysight.com/find/uxa110
09 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. The ADC clipping level declines at low frequencies (below 50 MHz) when the LO feedthrough (the signal that appears at 0 Hz) is within 5 times the prefilter
bandwidth (see table) and must be handled by the ADC. For example, with a 300 kHz RBW and prefilter bandwidth at 966 kHz, the clipping level declines
for signal frequencies below 4.83 MHz. For signal frequencies below 2.5 times the prefilter bandwidth, there will be additional reduction due to the presence
of the image signal (the signal that appears at the negative of the input signal frequency) at the ADC.
www.keysight.com/find/uxa110
10 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
11 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. Software preselection in its preset state (enabled). When not enabled, image rejection is nominally 0 dB.
2. N is the LO multiplication factor. Refer to page 4 for the N value verses frequency ranges.
3. Nominally -40 dBc under large magnetic (0.38 Gauss rms) or vibrational (0.21 g rms) environmental stimuli.
www.keysight.com/find/uxa110
12 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
13 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
General Specifications
Temperature range
Operating 0 to 40 °C
Storage –40 to +70 °C
Altitude
4,500 meters (approx. 15,000 feet)
EMC
Complies with the essential requirements of the European EMC Directive as well as current editions of the following standards (dates and editions are
cited in the Declaration of Conformity):
–– IEC/EN 61326-1
–– CISPR 11, Group 1, Class A
–– AS/NZS CISPR 11
–– ICES/NMB-001
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme a la norme NMB-001 du Canada.
South Korean Class A EMC declaration
This equipment has been conformity assessed for use in business environments. In a residential environment this equipment may cause radio interfer-
ence. ※ This EMC statement applies to the equipment only for use in business environment.
사용자 안내문
이 기기는 업무용 환경에서 사용할 목적으로 적합성 평가를 받은 기기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다.
※ 사용자 안내문은 “업무용 방송통신기자재”에만 적용한다.
Safety
Complies with the essential requirements of the European Low Voltage Directive as well as current editions of the following standards (dates and editions
are cited in the Declaration of Conformity):
–– IEC/EN 61010-1
–– Canada: CSA C22.2 No. 61010-1
–– USA: UL std no. 61010-1
Acoustic Statement (European Machinery Directive)
Acoustic noise emission
LpA < 70 dB
Operator position
Normal operation mode per ISO 7779
Environmental Stress
Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environ-
mental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude,
and power line conditions; test methods are aligned with IEC 60068-2 and levels are similar to MILPRF-28800F Class 3.
Power Requirements
Voltage and frequency 100/120 V, 50/60/400 Hz
220/240 V, 50/60 Hz
Power consumption
On 850 W (Maximum) 1
Standby 25 W
1. The actual power consumption depends on the configuration of the instrument. For example, power consumption of an N9041B with Option H1G installed
is nominally 620W.
www.keysight.com/find/uxa110
14 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. 584 mm (23 in) when the front handles are included.
www.keysight.com/find/uxa110
15 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Front Panel
RF input connector
Standard (for Input 1) 2.4 mm male, 50 Ω nominal
Standard (for Input 2) 1.0 mm male ruggedized, 50 Ω nominal
Probe power
Voltage/current +15 Vdc, ± 7% at 150 mA max nominal
–12.6 Vdc, ± 10% at 150 mA max nominal
USB ports
Master (3 ports)
Standard Compatible with USB 2.0
Connector USB Type-A female
Output current 0.5 A nominal
Headphone jack Miniature stereo audio jack (3.5 mm, also known as “1/8 inch”)
External mixing
Connection port
Connector SMA, female
Impedance 50 Ω nominal
Functions Triplexed for mixer bias, IF input and LO output
Mixer bias range ± 10 mA in 10 uA step
IF center frequency
≤ 25 MHz IF path 322.5 MHz
40 MHz BW IF path 250.0 MHz
255 MHz BW IF path 750.0 MHz
1 GHz BW IF path 750.0 MHz
LO output frequency range 3.75 to 14.1 GHz
Rear Panel
10 MHz out
Connector BNC female, 50 Ω nominal
Output amplitude ≥ 0 dBm nominal
Frequency 10 MHz + (10 MHz x frequency reference accuracy)
Ext Ref In
Connector BNC female, 50 Ω nominal
Input amplitude range –5 to 10 dBm nominal
Input frequency 1 to 50 MHz nominal (selectable to 1 Hz resolution)
Frequency lock range ± 2 x 10–6 of specified external reference input frequency
Trigger 1 and 2 inputs
Connector BNC female
Impedance > 10 kΩ nominal
Trigger level range –5 to +5 V (TTL) factory preset
Trigger 1 and 2 outputs
Connector BNC female
Impedance 50 Ω nominal
Level 0 to 5 V (CMOS) nominal
Sync (reserved for future use)
Connector BNC female
Monitor output 1
Connector VGA compatible, 15-pin mini D-SUB
Format XGA (60 Hz vertical sync rates, non-interlaced) Analog RGB
Resolution 1280 x 800
Monitor output 2
Connector Mini DisplayPort
Resolution 1280 x 800
www.keysight.com/find/uxa110
16 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
17 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Screen video
Operating conditions
Display scale types Log or Lin “Lin” is linear in voltage
Log scales All (0.1 to 20 dB/div)
Modes Spectrum analyzer only
Gating Gating must be off
Output scaling 0 to 1.0 V open circuit, representing bottom to top of screen
Offset ± 1% of full scale nominal
Gain accuracy ± 1% of output voltage nominal
Log video (Log envelope) output
Amplitude range (terminated with 50 Ω)
Maximum 1.0 V nominal for –10 dBm at the mixer
Scale factor 1 V per 192.66 dB
Bandwidth Set by RBW
Operating conditions Select Sweep Type = Swept
Linear video output
Amplitude range (terminated with 50 Ω)
Maximum 1.0 V nominal for signal envelope at the reference level
Minimum 0V
Scale factor If carrier level is set to half the reference level in volts, the scale factor is 200% of carrier level per volt.
Regardless of the carrier level, the scale factor is 100% of reference level per volt.
Bandwidth Set by RBW
Operating conditions Select Sweep Type = Swept
www.keysight.com/find/uxa110
19 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
20 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
21 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
www.keysight.com/find/uxa110
22 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Option B40 40 MHz analysis bandwidth (Option B40 is automatically included in Option H1G)
IF frequency response, 40 MHz IF (Option B40)
Input 1 Input 2
Frequency (GHz) Span (MHz) Preselector Max error Typical RMS (nominal) Max error RMS
≥ 0.03, < 3.6 ≤ 40 NA ± 0.37 dB ± 0.22 dB 0.07 dB Input 1 specification nominally applies
≥ 3.6, ≤ 8.4 ≤ 40 Off ± 0.5 dB ± 0.15 dB 0.05 dB Input 1 specification nominally applies
> 8.4, ≤ 26.5 ≤ 40 Off ± 0.7 dB ± 0.14 dB 0.05 dB Input 1 specification nominally applies
> 26.5, ≤ 34.4 ≤ 40 Off ± 0.8 dB ± 0.25 dB 0.07 dB Input 1 specification nominally applies
> 34.4, ≤ 50 ≤ 40 Off ± 1 dB ± 0.35 dB 0.07 dB Input 1 specification nominally applies
> 50 ≤ 40 NA NA NA NA ± 0.5 dB 0.02 dB
IF Phase Linearity, 40 MHz IF path (Option B40) Input 1 Input 2
Center Frequency Span Preselector Peak-to-peak RMS Peak-to-peak RMS
(GHz) (MHz) (nominal) (nominal) (nominal) (nominal)
≥ 0.02, < 3.6 ≤ 40 NA 0.4° 0.08° Same as Input 1 Same as Input 1
≥ 3.6, < 50 ≤ 40 Off 1.4° 0.3° Same as Input 1 Same as Input 1
> 50 NA NA NA 3° 0.5°
Dynamic Range, 40 MHz IF path (Option B40) Input 1 Input 2
SFDR (Spurious-free dynamic range)
Signal frequency within ±12 MHz of center -80 dBc, nominal Same as Input 1 up to 50 GHz
Signal frequency anywhere within analysis BW
Spurious response within ±18 MHz of center -79 dBc, nominal Same as Input 1 up to 50 GHz
Response anywhere within analysis BW -77 dBc, nominal Same as Input 1 up to 50 GHz
Full scale (ADC clipping) Mixer level Mixer level
Default settings (IF gain = Low), signal at CF
Band 0 -6 dBm, nominal Same as Input 1
Bands 1 through 4 -6 dBm, nominal Same as Input 1
Bands 5 through 6 -6 dBm, nominal Same as Input 1
Bands 7 through 8 NA -6 dBm nominal
High gain setting (IF gain = High), signal at CF, subject to gain limitations
Band 0 -7 dBm, nominal Same as Input 1
Bands 1 through 4 -14 dBm, nominal -12 dBm, nominal
Bands 5 through 6 -9 dBm, nominal -7 dBm, nominal
Bands 7 through 8 NA -7 dBm, nominal
Effect of signal frequency ≠ CF Up to ± 4 dB , nominal Same as Input 1
www.keysight.com/find/uxa110
23 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Option B40 40 MHz analysis bandwidth (Option B40 is automatically included in Option H1G)
(continued)
IF Residual Responses Across the Full BW Input 1 Input 2
Band 0 -110 dBFS nominal Same as Input 1
Bands 1 Preselector Off -110 dBFS nominal Same as Input 1
Third-order Intermodulation Distortion
(Two tones of equal level, 1 MHz separation, each tone -13 dB relative to the full scale (ADC clipping), IF gain = high)
Band 0 -85 dBc nominal Same as Input 1
Bands 1 through 5 Preselector Off -84 dBc nominal Same as Input 1
Bands 6 Preselector Off -79 dBc nominal -74 dBc nominal
Noise Density
Band Frequency (GHz) IF gain = Low IF gain = High IF gain = Low IF gain = High
0 1.8 -143 dBm/Hz -143 dBm/Hz Input 1 specification nominally applies
1 6.00 -140 dBm/Hz -140 dBm/Hz Input 1 specification nominally applies
2 10.80 -141 dBm/Hz -141 dBm/Hz Input 1 specification nominally applies
3 15.15 -135 dBm/Hz -135 dBm/Hz Input 1 specification nominally applies
4 21.80 -133 dBm/Hz -133 dBm/Hz Input 1 specification nominally applies
5 30.5 -130 dBm/Hz -130 dBm/Hz Input 1 specification nominally applies
6 42.25 -130 dBm/Hz -130 dBm/Hz Input 1 specification nominally applies
7 62.5 NA NA -145 dBm/Hz (nominal) -146 dBm/Hz (nominal)
8 92.5 NA NA -143 dBm/Hz (nominal) -144 dBm/Hz (nominal)
Data Acquisition, 40 MHz IF path (Option B40)
Time record length
Analysis tool
IQ analyzer 8,000,000 sample pairs Waveform
measurement
Advanced tool Data packing With 89600 VSA or fast capture
32-bit 64-bit
Length (IQ sample pairs) 536 MSa (229Sa) 268 MSa (228Sa) 2 GB total memory
Length (time units) Samples/Sample rate (IQ pairs)
Sample Rate, 40 MHz IF path (Option B40)
IQ pairs 1.25 x IFBW
ADC resolution 12 bits
www.keysight.com/find/uxa110
24 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Option B2X 255 MHz analysis bandwidth (Option B2X is automatically included in Option H1G)
IF Frequency Response, 255 MHz IF path (Included in Option H1G)
Relative to the Center Frequency Input 1 Input 2
Frequency Span Preselector Max error Typical RMS Max error RMS
(GHz) (MHz) (nominal) (nominal) (nominal)
≥ 0.4, < 3.6 ≤ 255 NA ± 0.74 dB ± 0.4 dB 0.1 dB Input 1 specifications nominally apply
≥ 3.6, ≤ 8.4 ≤ 255 Off ± 0.82 dB ± 0.34 dB 0.1 dB Input 1 specifications nominally apply
> 8.4, ≤ 50 ≤ 255 Off ± 0.8 dB nom. 0.2 dB Input 1 specifications nominally apply
> 50 ≤ 255 NA NA NA ± 1 dB 0.2 dB
IF Phase Linearity, 255 MHz IF path (Included in Option H1G) Input 1 Input 2
Center Frequency Span Preselector Peak-to-peak RMS Peak-to-peak RMS
(GHz) (MHz) (nominal) (nominal) (nominal) (nominal)
≥ 0.4, < 3.6 ≤ 255 NA 2° 0.4° Same as Input 1 Same as Input 1
≥ 3.6, < 50 ≤ 255 Off 2° 0.3° Same as Input 1 Same as Input 1
≥ 50 NA NA NA 2° 0.4°
Dynamic Range, 255 MHz IF path (Included in Option H1G) Input 1 Input 2
SFDR (Spurious-free dynamic range)
Signal frequency anywhere within analysis BW -78 dBc , nominal Same as Input 1 up to 50 GHz
Full scale (ADC clipping) Mixer level Mixer level
Default settings (IF gain = Low), signal at CF
Band 0 +3 dBm, nominal Same as Input 1
Bands 1 through 4 +3 dBm, nominal Same as Input 1
Bands 5 through 6 +1 dBm, nominal Same as Input 1
Bands 7 through 8 NA +5 dBm, nominal
High gain setting (IF gain = High), signal at CF, subject to gain limitations
Band 0 +3 dBm, nominal Same as Input 1
Bands 1 through 2 -3 dBm, nominal Same as Input 1
Bands 3 through 4 -4 dBm, nominal Same as Input 1
Bands 5 through 6 +1 dBm, nominal Same as Input 1
Bands 7 through 8 NA +5 dBm, nominal
Effect of signal frequency ≠ CF Up to ± 4 dB, nominal Same as Input 1
IF residual responses across the full BW
Band 0 -110 dBFS, nominal Same as Input 1
Bands 1 Preselector Off -108 dBFS, nominal Same as Input 1
Third-order intermodulation distortion
(Two tones of equal level, 1 MHz separation, each tone -23 dB relative to the full scale (ADC clipping), IF gain = high)
Band 0 -85 dBc , nominal Same as Input 1
Bands 1 through 4 Preselector Off -85 dBc , nominal Same as Input 1
Band 5 Preselector Off -80 dBc , nominal Same as Input 1
Band 6 Preselector Off -73 dBc, nominal Same as Input 1
Noise density
Band Frequency (GHz) IF gain = Low IF gain = High IF gain = Low IF gain = High
0 1.8 -142 dBm/Hz -141 dBm/Hz Input 1 specifications nominally apply
1 6.00 -141 dBm/Hz -142 dBm/Hz Input 1 specifications nominally apply
2 10.80 -140 dBm/Hz -141 dBm/Hz Input 1 specifications nominally apply
3 15.15 -137 dBm/Hz -137 dBm/Hz Input 1 specifications nominally apply
4 21.80 -135 dBm/Hz -135 dBm/Hz Input 1 specifications nominally apply
5 30.5 -130 dBm/Hz -130 dBm/Hz Input 1 specifications nominally apply
6 42.25 -130 dBm/Hz -130 dBm/Hz Input 1 specifications nominally apply
7 62.5 NA NA -140 dBm/Hz, nom. -140 dBm/Hz, nom.
8 92.5 NA NA -139 dBm/Hz, nom. -139 dBm/Hz, nom.
www.keysight.com/find/uxa110
25 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Option B2X 255 MHz analysis bandwidth (Option B2X is automatically included in Option H1G)
(continued)
Data Acquisition, 255 MHz IF path (Included in Option H1G)
Time record length
Analysis tool
IQ analyzer 8,000,000 sample pairs Waveform measurement
Advanced tool Data packing With 89600 VSA or fast capture
32-bit 64-bit
Length (IQ sample pairs) 1073 MSa (230Sa) 536 MSa (229Sa) 4 GB total memory
Maximum IQ capture time (advanced tools) Length of IQ sample pairs/Sample rate (IQ pairs)
Sample rate (IQ pairs) Minimum of (1.25 x IFBW, 300 Msa/s)
ADC resolution 14 bits
www.keysight.com/find/uxa110
26 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. In the 1 GHz bandwidth path, the span and bandwidth will be 40 MHz minimum. Below 40 MHz, a narrower IF path is used.
2. Signal Level is -6 dB relative to full scale at the center frequency.
3. T he residual performance is dominated by a single residual 50 MHz to the left of the center of the screen. It is an artifact of the ADC architecture. If residual
performance is critical and span requirements are flexible, then reducing the span to 255 MHz and making use of the 255 MHz IF path will eliminate this
residual.
www.keysight.com/find/uxa110
27 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
1. A noteworthy group of harmonically related sidebands is often present with a level of nominally -80 dBc at 300 Hz and envelope falling off (30 dB/decade)
with increasing offsets.
2. Nominally -40 dBc under large magnetic (0.38 Gauss rms) or vibrational (0.21 g rms) environmental stimuli.
3. N is the LO multiplication factor. Refer to page 3 for the N value verses frequency ranges.
www.keysight.com/find/uxa110
28 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Related Literature
UXA Configuration Guide, 5992-2112EN
www.keysight.com/find/uxa110
29 | Keysight | N9041B UXA X-Series Signal Analyzer, Multi-touch - Data Sheet
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacific
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 11 2626
Japan 0120 (421) 345
myKeysight Korea 080 769 0800
www.keysight.com/find/mykeysight Malaysia 1 800 888 848
A personalized view into the information most relevant to you. Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
http://www.keysight.com/find/emt_product_registration
Register your products to get up-to-date product information and Europe & Middle East
find warranty information. Austria 0800 001122
Keysight Services Belgium 0800 58580
Finland 0800 523252
www.keysight.com/find/service
France 0805 980333
Keysight Services can help from acquisition to renewal across your
Germany 0800 6270999
instrument’s lifecycle. Our comprehensive service offerings—one- Ireland 1800 832700
stop calibration, repair, asset management, technology refresh, Israel 1 809 343051
consulting, training and more—helps you improve product quality Italy 800 599100
and lower costs. Luxembourg +32 800 58580
Netherlands 0800 0233200
Keysight Assurance Plans Russia 8800 5009286
www.keysight.com/find/AssurancePlans Spain 800 000154
Up to ten years of protection and no budgetary surprises to ensure Sweden 0200 882255
your instruments are operating to specification, so you can rely on Switzerland 0800 805353
accurate measurements. Opt. 1 (DE)
Opt. 2 (FR)
Keysight Channel Partners Opt. 3 (IT)
www.keysight.com/find/channelpartners United Kingdom 0800 0260637
Get the best of both worlds: Keysight’s measurement expertise and
product breadth, combined with channel partner convenience.
For other unlisted countries:
www.keysight.com/find/contactus
www.keysight.com/find/uxa110 (BP-9-7-17)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System