chrom atogr aphy

Product Specif ications


Thermo Scientific
C2V-200 Micro GC
Built for fast reliable gas analysis

• Your gas analysis in seconds Fast, Reliable and Simple. Flexible Configuration
• Fast temperature programming And Cost Efficient! The C2V-200 micro GC channels are
• Configurable to your demand The Thermo Scientific™ C2V-200 micro GC independently operating micro GC’s, which can
is built for fast reliable gas analysis, in the lab be assembled as one integrated instrument
or on-line. Integrated micro chip technology with common sample and carrier path.
combined with narrow bore capillary GC Alternatively, they can be deployed as
columns result in a higher performance for individual stand-alone instruments. No up
lower costs. The C2V-200 micro GC is front investment is required to upgrade your
designed for ease of use, reduced C2V-200 micro GC with an additional GC
maintenance, and low gas consumption. channel at a later time.
The exchangeable column cartridges, with
integrated heating zones, can be easily Immediate Start-Up and Easy Control
installed for a variety of applications. The C2V-200 micro GC is delivered with
dedicated instrument control and data-handling
software to run on a PC. This brings you up to
speed the moment you unpack the C2V-200.

For process solutions, an optional NeSSI


(SP76-1.0) compatible adaptor plate enables
the integration on this flexible sampling system.
micro GC column cartridges (60 × 100 × 12.5 mm)

Analysis in Seconds
The integrated micro chip injector ensures a
precise narrow injection bandwidth, while the
2-channel C2V-200 micro GC instrument fast column temperature programming gives
an extra dimension in method optimization.
Together this enables fast and highly repeatable
analysis results in seconds.

Column Temperature Programming


With a speed of 240 °C /minute, the micro GC C2V-200 micro GC on NeSSI platform
columns can be temperature-programmed
up to four temperature segments. This
unique capability enables faster solutions.

Flexible configuration of a
4-channel micro GC, into
four 1-channel GC instruments
Product Specifications

Produ c t Spe ci f i cat i ons


Configuration Detection Limits Instrument Control
Flexible configurable 1-4 channel integrated • WCOT columns: <2 ppm • C2V-micro GC software, compatible with
micro GC system. Modular and independently • PLOT columns: <8 ppm Microsoft® Windows® XP, Windows Vista®,
operable without pre-investments for future and Windows 7
Limits will vary by component, sample matrix,
expansion. • Communication: USB 2.0, RS-232,
injector type, carrier gas and interferences. optional RS-485
Operating Range • Control and read-out of up to 4 micro
GC channels
• Concentrations: 2 ppm to 100%
• Method development
4-channel C2V-200 • Linear dynamic range: 106
• Sequence builder with method and stream
micro GC selection
Repeatability
• <0.4% RSD on peak area Data Handling
Column Cartridge • < 0.2% RSD on peak retention time for • Peak identification, integration
WCOT columns with C1-C6 components at • Single run and sequence reporting
Column cartridges include heated detector/
% level, at constant ambient 25 °C
injector zone and a column in an oven with • Trend analysis, statistics
temperature programming. Standard available Column Temperature Control • Printing in PDF format
column types PDMS, MS5A, U-PLT, U-BND, 2 modes: Isothermal or T-programmable Software Option
QS-BND and ALOX. • NGAC-Natural Gas Application Calculation
Isothermal C6+ acc. to ISO 6976, ASTM D3588, and
Sampling • Minimum 50 °C to 180 °C GPA 2172
• Sample conditions: non-condensing gas of • Temperature stability: <0.2 °C Hardware Option
0 °C to 50 °C
Temperature Programming • 4-20 mA output
• Sample inlet: 1.6 mm (1/16") stainless
steel Valco® fitting with replaceable 5 μm • Minimum 50 °C to 180 °C Power
stainless steel filter • T-ramp up: 240 °C per minute Power supply for 2 micro GC channels:
• Recommended sample inlet pressure/flow: • T-ramp down: 60 °C per minute • Input: 100–240 Vac, 50–60 Hz, 200 VA
50 kPa (7 psig), 5 mL/min. Max sample • Temperature repeatability: ≤0.2 °C • Output: 2x 24VDC 4A,
inlet pressure 100 kPa (15 psig) typical 20W, max 2x 100W
• T-programming profile: up to 4 segments
Optional, Software Controlled Environmental Conditions
and Integrated Carrier Gas
• Operating temperature range: 35 °C–50 °C
• 2 -Stream selector (double block and bleed) • All major carrier gasses helium, nitrogen
and argon. Hydrogen use requires a • Relative humidity: 5 to 85%, non-condensing
• Sample aspiration pump with fast purge safety device. • Altitude: to 2000 m
Integrated Sample Injector • Instrument inlet: 500 ± 10 kPa
(72.5 ± 1.5 psig)
Dimensions/Weight per Micro GC
and Detector Channel/Module
• MEMS based injector and detector are • Column pressure control 50 – 300 kPa,
user selectable Max. Weight: 3.5 kg/1 kg
on-chip integrated (avoiding capillary
connection tubes), with a direct • Carrier inlet: 1.6 mm (1/16") stainless Height: 15 cm/12.5 cm
column/chip coupling steel Valco fitting with replaceable 5 μm Width: 12 cm/8.5 cm
stainless steel filter Depth: 12 cm/6 cm
Sample Injector
• Heated injector up to 120 °C Optional: different carrier gas per channel
• MEMS based injector without moving parts
External Input/Output
• Injection volume: 0.2 μL to 9.0 μL, time
based software selectable • 4x external valve control
• Analog I/O: 2x 0-5 V in
Detector
• Analog I/O: 2x 0-5 V out
• Dual-channel MEMS micro Thermal
Conductivity Detector (TCD) • Remote start (signal input)
• Internal flow path: 20 nL • Start out (signal output)
• Inert coated filaments

www.thermoscientific.com
©2011-2012 Thermo Fisher Scientific Inc. All rights reserved. Microsoft, Windows and Vista are registered trademarks of Microsoft Corp.
Valco is a registered trademark of Valco Instruments Co. Inc. and VICI AG. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

C2V - Thermo Fisher Scientific Tel: +31 534 889 889 For more information or a live demonstration, please contact:
Colosseum 20 Fax: +31 534 889 890
7521 PT Enschede Email: microGC-info@thermofisher.com
Netherlands Web: www.C2V.nl