Вы находитесь на странице: 1из 1

Chemical flowrate and Storage Tank capacity

Storage tank 
Holding time, 
Propose Tank dimension capacity, m3  Holding time, hr
Injection rate,  Injection rate,  hr Actual chemical  Minimum chemical 
No. Tag No Unit chemical Operation (Note‐1) remark Density, kg/m3
m3/hr mL/hr Required on site Required on site
ID , m  H, m
PPL PPL AXENS
(PPL) (PPL)
1 PK‐201 NHT DMDS Intermittent 0.068 68000 1.2 3 3.39 49.9 1060 3595 kg 860 kg

2 PK‐202 NHT Corrosion inhibitor (Note‐1) continuous 0.0017 1700 0.15 0.75 0.01 7.8 need agitator to mix corrosion inhibitor and heavy naphtha 750 10 kg 446 kg 30 days residence time (pure)

3 P‐206 A/B NHT washing water Intermittent 0.44 440000 0.692 1.2 0.45 1.0 1000 1.0 hr 0.5 hr

4 PK‐301 CRU Demin. Water Intermittent 0.16 160000 0.300 1 0.07 0.4 1000 71 l 30 l 15 days residence time

5 PK‐302 CRU Tetrachloroethylene (C2Cl4) (Note‐2) Intermittent 0.012 12000 0.8 3 1.51 125.6 need agitator to mix C2Cl4 and hydrotreated naphtha 750 1130 kg 70 kg 15 days residence time (pure)
30 minutes (0.5hr) residence 
6 PK‐303 CRU Demin. Water Intermittent 6.66 6660000 1.5 2.7 4.77 0.7 1000 4.77 m3 2.7 m3
time
7 PK‐304 CRU 25 wt% caustic Soda Intermittent 0.29 290000 1.5 3.7 6.54 22.5 need agitator to mix 25% caustic soda 1270 6.54 m3 2.4 m3 8 hrs residence time
Tetrachloroethylene (C2Cl4) &
8 PK‐305 CRU Intermittent 0.04 40000 1.5 3.4 6.01 150.1 need agitator? 1623 9747 kg 5334 kg
DMDS ?
Notes:

1. Tank size should be design to ensure manual measuring and proper mixing if aplicable 
2. 10%wt CHIMEC diluted in Heavy Naphtha
3. 1wt% C2Cl4 diluted in Hydrotreated Naphtha
4. Tank dimension should consider the mixing tool and manual level glas to measure injection flowrate

Вам также может понравиться