1/2-Loop Fire Panel
Panel 1 loop or 2 loops,235 devices for 1st loop,242 device for 2nd loop
30 zones fire and fault/disable indication
PAS and Acknowledge Function
Dirty detector reporting
Walk test feature
Build in RS485 repeater output, (maximum10 repeaters)
Standard: EN54-2/EN 54-4
Mains supply: 220/230VAC 50/60Hz
Backup battery: 24VDC/22AH
2
Addressable Fire Panel
3
Addressable Fire Panel
4
Addressable Fire Panel
5
Addressable Fire Panel
6
Addressable Fire Panel
P-9960
Class B CAN network card
Specification:
7
Addressable Fire Panel
P-9960A
Class A CAN network card
Specification:
8
Panel Overview GST-200-2 Structure
Structures
9
Panel Overview GST-200-2 Fascia
Fascia
Terminal Board
Panel PSU (Loop 1 interface Board)
AC Power Filter
230V to27V AC Transformer
11
Panel Overview GST-200-2 Internal Parts Overview
LCD Screen
12
Panel Overview GST-200-2 Internal Wiring Diagram
H L1 H L2
+ +
Serial port
RS 232 CARD XS2
(Optional) D1
USB port
XS3
XS1
F7.820.913
Network CARD + + +
P-9940A B1
D1
H L3 H L2 H L1
B2
A1
A2
XT1
B2
OTHER FACP B1
A1 A2
H L2
A SPEAKER
+
Loop 2 CARD XS12
ZO+ ZO-
B
XT1
EXTENDED PORT
01 02 Z1 Z2
(GS200/2/1-Optional)
LOOP 2
XS7
SPEAKER
Loop 2 CARD
ZI+
XT3
D17
ZI-
(GS200/2/2-Supplied) XT2 + 2 4 V G N D
H L1 H L3
24V+
D8 D9
System
+
+
24V- D4
SK1
BAT Fault
AC Fault
5V
F7.820.828V1
GND
LED PORT
A
XT12
XS6 BACK
B A B
RS 485
XS11 LIGHT
+
NETWORK
REPEATER
XT10
XT11
A
RS 485
Diagram
B
+
LOOP OUT
NETWORK
Loop 1 Board
A
XT4
XT9
LOOP BUS
_
D2 D1 Z- Z+ B
_LOOP IN
XT2
XT1
XT13
XT5
OUTPUT
ALARM
_
FIRE
BUS
+
LOOP OUT
Terminal Board
OUTPUT
XT6
_
F.E.P.
HL
HL HL HL
(Supplied)
+
HL
LOOP OUT
HL HL HL
+ +
_
XT7
OUTPUT
CIRCUIT
SOUNDER
+ + + + + +
HL
G ND + 24V + 24V G ND + 5V G ND G ND + 5V HL HL
HL
HL
HL HL HL
+ + + + + + + +
+ +
HL
HL
+ +
HL
HL
+ + +
HL
HL
+
HL
NC COM NO
HL HL HL
HL
HL HL HL
FAULT OUTPUT
X4 + +
+ + + + + +
XT8
HL
HL HL HL
HL
HL5 HL HL HL
+ + + + + + + +
CLASS CHANGE
HL
HL HL HL
XT3
HL
HL HL HL
+ + + + + + + +
HL
HL HL HL
HL
HL HL HL
F1
+ + + + + + + +
X5 HL2 HL
HL HL HL HL
HL HL HL
X6 X1
+ + + + + + + +
F2 G ND + 5V
HL
HL HL HL
HL
HL3 HL HL HL
X7 + + + + + + + +
X2
F3
HL4
EARTH
X3
X8
A C Input
32 Manual Intervention zone and indicator board Printer
F7.820.829bV1
Fuse
L G N
AC Filter FAULT
_ BAT +
0 I 0 I AC 16-30V
AC220V
2A
24V Batteries
Step-down Transformer
- + - +
12V 12V
13
Panel Overview GST-200-2 External Wiring Diagram
Terminal
Monitored
A
A
REPEATER
XT12
RS 485
B
B
REPEATER
XT10
A
NETWORK
No connec tion
XT11
Board
Refers to Optional
RS 485
B
Network Board
A
NETWORK
+
LOOP OUT
XT9
Loop Out (Out to First Device)
XT4
Z+ B
BUS
LOOP
Monitore
_
LOOP 1
XT1
LOOP IN
_
D2 D1 Z-
+
XT13
OUTPU
ALARM
+
LOOP OUT
XT5
+
FIRE
4.7Kohm s
BUS
O/P
Standby Volatge:-9 to -
EOL
A
_
Output Device with Sounder with
fitted diode built-in diode
Monitored
TLOOP OUT
OUTPU
+
F.E.P.
Monitored
XT6
+
OR
+
4.7Kohm s
EOL FPE FPE
_
Non
FPE with
fitted diode
11VDC
SOUNDE
OUTPUT
CIRCUIT
+
LOOP OUT
XT7
+
+
4.7Kohm s
R
EOL
_
Sounder with Sounder with
fitted diode built-in diode
NC COM NO
FAULT OUTPUT
Monitored
X4
XT8
HL5
Non
CLASS CHANGE
XT3
F1
HL2
X5
Terminal/Output Board X6
F2
X1
HL3
X7 X2
F3
HL4
E AR T H
X3
X8
14
Panel Overview GST-200-2 System Diagram
Stand-alone Architecture
GST200-2/1 – Capacities
•235 devices
•1.0 km max loop length
•1.5mm2 UTP fire cable
15
Panel Overview GST-200-2 System Diagram
Stand-alone Architecture
GST200-2 – Capacities
•Loop 1 -235 devices
•Loop 2 – 242 devices
•1.0 km max loop length
•1.5mm2 UTP fire cable
16
Panel Overview GST-200-2 Repeater and GMC connection
Stand-alone Architecture
•Built-in Repeater/Mimic Output
• Up to 10 points
• RS485 – 1000meters
• GSTGMC-up to 8 users
• Required P-9930
•RS232- 15 meters
17
Panels Networking
18
Panels Networking
Network
19
Panels Networking
RS 232 Card
20
Panels Networking
RS 232 Card
21
Panels Networking
P-9960 P-9960
P-9965
Total Cable Length 3.5 Km (max)
P-9965
CAN HUB
CAN100H-4/8/12/16
P-9960 P-9965 P-9965
P-9960 22
Panels Networking
•Maximum 99 FACP
Fiber Optic Network
•Recommend 32 FACP
RS485 Class B Fiber Optic Network
Fibre Optic
+ +
P-9940A P-9945A
(For Single-Mode-25KM)
Interface FIB485S01
Optic
Optic
Fibre
Fibre
(For Multi Mode -4.5km)
Interface FIB485M01
+ +
P-9940A P-9940A
23
Panels Networking
(For Single-Mode-25KM)
Interface FIB485S01
Fibre Optic
Fibre Optic
Fibre Optic
+ +
P-9940A P-9940A
24
Panels Networking
TCP/IP Network
+ +
TCP/IP
+
+
NPort5230 + P-9930TCP/IP
P-9935 TCPIP + NPort5230
25
Product Overview
26
Initiating Device
DB-01 C-9314P
Standard Base Remote Indicator
27
Initiating Device
DB-01 C-9314P
Standard Base Remote Indicator
28
Initiating Device
DB-01 C-9314P
Standard Base Remote Indicator
29
Initiating Device
Beam Detector
Infrared beam detector
Detection range 8 to 100 meters
Path width 7 meters each side
1 to 4 reflectors for different path length
Standard EN54-12
Electronically addressed by programmer
Additional Fire and Fault dry contact relay output
24VDC supply required
I-9105R
Reflective Beam Detector
30
Initiating Device
D-92FC D-92WPB
31
Notification Device
C-94DB
Optional deep base for I-9403
32
Notification Device
C-94DB
Optional deep base for I-9404
33
Notification Device
DI-9405 Addressable
“sandwich” structure
Sounder Base
Termination suitable for “DI” range detectors
Loop powered
Maximum 30 pieces per loop
Three working modes settable (Mode I, II, III,
and the latter two available with pre-alarm state).
16 tones of sound.
Electronically addressed. The address and
tones can be modified in field.
Tone 14 and 16 are certified by EN54-3.
34
Notification Device
DI-9406 Addressable
Sounder Beacon Base “sandwich” structure
Termination suitable for “DI” range detectors
16 selectable tone
Loop powered
Maximum 30 pieces per loop
Three working modes settable (Mode I, II, III, and
the latter two available with pre-alarm state).
35
Interface
Input Interface
Intelligent single input module
Monitors switch contacts of remote equipment
Loop Powered
Cable monitored
Standard EN54-18
Electronically addressed by handheld
programmer
I-9300 Input Module LED status indicator
36
Interface
Input Interface
Intelligent zone monitor module
Interface with conventional fire devices
24VDC required
Cable monitored
Standard EN54-18
Electronically addressed by handheld
programmer
I-9319 Zone Interface Module LED status indicator
37
Interface
Output Interface
Intelligent single output module
24VDC/3A, 110VAC/3A dry contact output – Loop
Powered
Interface with conventional polarized sounders –
24VDC required
LED status indicator
Standard EN54-18
38
Isolator
Loop Isolator
39
Isolator
40
Isolator
41
Programmer
Handheld Programmer
P-9910B Programmer
42
Repeater Panel
43
Repeater Panel
44
Repeater Panel
45
Graphic Station
46
Configuration, Operation and
Programming
2014 V1.2
System Configuration
To configure a system
1. Decide panel type and quantity. If more than one panel is configured,
add network card to each panel.
2. Decide loop quantity. Remember leave at least 20% of loop quantity for
future expansion.
48
Addressable Fire Panel
49
System Configuration
50
System Loop Parameter
Loop
51
System Loop Parameter
52
System Loop Parameter
53
System Loop Parameter
54
GST200-2 Panel Operation
55
Panel Operation GST200-2
Registration : 24220011
56
Panel Operation GST200-2
Browse
Zone: 001 GND FLR
No: 003 MCP
Loop Devices: View the number of devices per loop and Sensitivity: Nominal
Left W ing Corridor
detailed provided with each device
Browse
02 Zone (008)
Zone: 01 (001) 003
Zone Devices: View the number of Input devices per zone
Zone : 02 (002) 001
Group Device: View number of Output devices per zone
Browse
In Test Mode Zones: View which zones are in test mode
Sum: 003
COM Devices: View the number of Control Panel and Repeater panel Repeater01
Net Unit 01
connected in the system
Net Unit 02
58
Panel Operation GST200-2
PAS MODE
Fire signal from detector shall be acknowledged at the panel within 15 sec in order to
initiate the alarm investigation phase. Trained personnel shall have up to180 sec to
investigate.
•Fire signal not acknowledged w/in 15 sec – Outputs (Equation) immediately activated
•Panel not reset during the 180 sec – Outputs (Equation) immediately activated
•Second fire signal during the 180 sec – Outputs (Equation) immediately activated
Notes:
•Press Evac override PAS
•MCP is exempted (BS5839 P1:2.19)
59
Panel Operation GST200-2
TEST MODE LED will on Corresponded Zone Yellow LED will lit
3 Stop a Zone Test
4 Stop All Zones Test
60
Panel Operation GST200-2
Disable/Enable Menu
1 Disable Devices
1 Each Zone Fully 1Disable Devices
2 Enable Devices
2 Individual Point 3 3 Dis/En-able Output
All Loop Sounder 4Dis/En-able Delays
5 Delete Net Disable
4 Use Device Code
2 Enable Devices
1 Each Zone Fully
2 Individual Point
3 All Loop Sounder
4 Use Device Code
3 Dis/En-able Output
1 Sounder Circuit Disabling a Point Enable
2 F.P.E Output Loop: 1 Point : 001 Z001C125T03 Optical
4 Dis/En-able Delays:
1 Disable - ( default setting) By address Using device code
2 Enable- Delay in C&E equations will be effective
5 Delete Net Disable to delete not existing disable messages from network
61
Panel Operation GST200-2
62
Panel Operation GST200-2 Register
GST200-2
SYSTEM
1. Press “System (9)” 1Time/Date
2 Password Change
2. Enter the password “24220011” 3 Network Setup
4 Zone Start Number
(Factory set Commission Password) 5 Customize
6Initialize System
then Press “Enter” 7 Device Debug
63
GST200-2 Basic software
Configuration
64
GST Definition software installation
65
GST200-2 Panel addressing
11.Set up panel
10.Net local
9.Net work setup address . Enter to
address
confirm
2.Connect download
1. Power On 3.Run GST
card USB cable to 4.Select Com Port
GST200-2 Definition Software
computer USB port
9. Define
5.Add panel,
10.Define Zone 8.Define 7. Define devices 6.Add zone,
select panel
Repeater indication Cause & (zone , device define
type and panel
(Option) and control Effect type and Location) zone
address
switch
Save and Save and Save and Save and Save and
Download Download Download Download Download
67
Basic Software Configuration GST200-2
The device code is the device unique ID on standalone FACP or whole FACP network. So before
addressing and programming devices, below points should be noted:
1. In same zone, in case the devices from different loop or different panel, the device address + device
type can not be same as other device’s. for example: in zone No.1 already has smoke detector
address No.1 from loop1, and in this zone has another smoke detector from other loop or other
panel, the device address can not be No.1 again. Or if use address No.1, can not given to smoke
detector.
68
Basic Software Configuration GST200-2
1. The maximum zone number for GST200-2 is 60, if the panel in network, and whole network
zone numbers more than 60. for example 4 GST200-2 panels in network, each panel include
20 zones. Total 80 zones. The commissioning engineer can set the devices in panel No.1 to
zone 1 to 20, devices in panel No.2 to zone 21 to 40, devices in panel No.3 in zone 41 to 60.
and devices in panel No.4 in zone 1 to 20, then set the start zone number on panel No.4 is 61.
then the zone 1 on panel 4 will be displayed as zone 61 on local and network panel.
2. On GST200-2 panel, the network fire signal cannot use as local panel Cause & Effect
condition.
3. Local panel can send activation command to network. Such as above example if in case fire
on panel 1 want to active module on panel No.4, must save cause & Effect on panel No.1,
the activation device code must be the displayed number, for example 061001 13. not the
local programmed code.
69
Basic Software Configuration GST200-2
70
Basic Software Configuration GST200-2
71
Basic Software Configuration GST200-2
2. Number of Loop
72
Basic Software Configuration GST200-2
3. Zone Configuration
Adding a zone
1.Click the “FACP Zone” icon
2.Right-click “Panel that will add zone” and select “Add Zone”
3.Or Click the “New” icon
Note: Max number of zone is 60
Zone ID : Zone number
ForeColor: Font Color
BackColor: Text Highlight Color
Description: Zone name (note: 8 Max character)
Example: Zone example
4.To save click the “Save” icon
73
Basic Software Configuration GST200-2
4. Device Detailed
Device Configuration per Loop
1.Click the “FACP Net” icon
2.Click “Panel to be programmed”
3.Click the “Loop 1”
Address: 1-242
Loop Number: Loop Assignment
Zone: Zone assignment
Device Type: Selection of device type.
Properties: For output- 0-on/off ;
1-continoues
Location: Device location information
Note: GST200-2 character 32 max: 21
first line; 11 second line
Registered: Once the data is
uploaded from the panel, it will
indicate TRUE if the particular device
is being found or registered in the
panel ,otherwise it will indicate False.
4. Click Save icon to save
74
Basic Software Configuration GST200-2
2.Click the
“Device Type –icons
76
Basic Software Configuration GST200-2
Condition
G01 020 03 meaning Address 20 Optical smoke in Zone 1 (By Point)
S02 001 11 (Fuzzy Logic)meaning At least 1 (Amount) MCP regardless of address in Zone 2
(By Zone)
S** 002 02 (Fuzzy Logic) meaning 2(Amount) Heat det. should alarm at same time in the entire area
(Global)
Effect:
S**001 31 12 meaning latch all lift module after 2 minutes –regardless of quantity.
Sample Equation:
77
Basic Software Configuration GST200-2
Keys: 1-30
Address of Device to Start: Select the address of a devices/s that wish to
control
Zone to Display: Select the zone number that wish to display
Function: The control switch function-auto change
78
Basic Software Configuration GST200-2
79
Basic Software Configuration GST200-2
Click “Backup Database” to save the data. Click “Restore Database” to retrieve the data.
Save the data to the required location Locate the saved data
80
Basic Software Configuration GST200-2
3 important things:
1. Registration of RS232 download card (Hardware)
GST200 Series
Press “System” Enter the password 24220011 Press “Enter”
Press “SK1 button” behind the door.
(Note: procedure should be done within 25 seconds and HL1 red LED will blink indicates that the card is registered)
2. Set Serial Port number (USB Connection-My computer-Properties-Hardware-Device Manger-Port)
3. Matched the address of the control panel “Local Address from the GSTDef software “FACP Address”.
To view the control panels address:
Press “System” 3 Network Set-up 1 Net Local Address
81